You are on page 1of 24

Hospital Grade

Receptacles
Power Status
Tamper-Resistant
SmartLock Pro

Surge & IG
Power Quality
Panels
Power Strips
Occupancy Sensors
B-1027C HealthBrochure.qxd 7/11/06 2:02 PM Page 2
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
Hospital Grade
15 & 20 Amp Straight
& Angle Devices
HG Power Indication
Plugs & Connectors
20 Amp Hospital Grade
Power Interrupting
Devices
15-60 Amp NEMA &
Non-NEMA Straight
Blade Devices
15-30 Amp NEMA &
Non-NEMA Locking
Devices
Infrared, Ultrasonic & Multi-Technology Units
Individual Units Cover 180 & 360 Degrees,
Up to 2000 Square Feet
Ambient Light Override Feature
Self Contained Units for 120 or 277V Circuits
Ultrasonic & Multi-Technology Units Require
Separate Power Pack
Cage Available for High Abuse Areas
PAGES 19-21
Available with Infrared
and Adaptive Infrared
Technologies
Ambient Light Override
Feature
Single Unit Operates On
120 or 277V and Can
Handle Incandescent or
Fluorescent Loads
Single & Dual Relay
Options
Device Fit Standard
Switch Boxes & Utilize
Decora Wallplates
PAGE 19
Available Technologies
Include Infrared,
Ultrasonic &
Multi-Technology
Individual Units Cover
110 and 360 degrees,
up to 2500 square feet
Ambient Light Override
Feature
Ultrasonic & Multi-
Technology Units Require
Separate Power Pack
Infrared High-Bay
Version Available with
Secondary Relay Option
PAGE 21
H
e
a
l
t
h

C
a
r
e

P
r
o
d
u
c
t

T
y
p
e
s
1
Health Care Product Types
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
Protection at Facility Service Entrance
Advanced Diagnostics for Monitoring Trends
in Surge Events on LCD Display
Models Available for Generator Transfer
Switch, Panelboard and Dedicated
Equipment Applications
PAGES 13 & 14
SURGE PROTECTION SURGE STRIPS SURGE PANELS
FOUR-IN-ONE GFCI SMARTLOCK

PLUGS & CONNECTORS


SWITCH MOUNT CEILING MOUNT WALL MOUNT
Hospital Grade
15-20 Amp Duplex &
Single Congurations
Interlocking
Thermoplastic Nylon
Cover & Body
Permanent "Green Dot"
Marked on Face
Nickel-Plated Brass
Strap with Integral
Ground Contacts
Back & Side Wired
Ground Termination
Hospital Grade
15 Amp version has a
nickel plated steel strap
20 Amp version has a
nickel plated brass strap
and a 1 piece mounting
strap/grounding system
Mechanical Safety
Shutters
Interlocking
Thermoplastic Cover
& Body
Approved for Emergency
Circuits and
Pediatric/Psychiatric
Care Areas
Hospital Grade
15-20 Amp
Congurations
100,000 Hr.
Green LED Power
Status Indicator
Permanent "Green
Dot" Lens
Suitable for Critical
Care Areas and
Emergency Circuits
Nickel-Plated Brass
Strap with Integral
Ground Contacts
Full Illuminated Face
Also Available
HOSPITAL SPEC TAMPER-RESISTANT POWER INDICATION
8300-R
8300-SGI
8300-PLW
74120-7M3
Hospital Grade
15-20 Amp Congurations
Hospital, Surge and IG Versions
Thermoplastic Nylon Face and Body
Universal Mounting
8490-IGG
ODS0D-IDW
ODW12-M0D
Hospital Grade
15-20 Amp Duplex
Congurations
Back & Side Wired
LED Status Indicator
Prevents Reset if
Protective Function is
Compromised
Prevents Reset in Case
of Line-Load Reverse
Wiring
Meets New UL
GFCI Requirements,
Effective 2006 8598-HGW
Hospital Grade
15-20 Amp Duplex &
Single Congurations
Surge & IG Versions
Audible and Visual
Protection Status
Alarms
Back & Side Wired
Thermoplastic Nylon
Cover & Body
PAGE 8
8280-IGB
8215-C
8319-C
Six Outlet, 6 Cord with
Hospital Grade Plug &
Receptacles
No Switch Provided
Power is Always ON to
Avoid Accidental
Shutdown
Three Mode Protection
with Leakage Current
Below 100 Microamps
Tamper Resistant
Receptacles
PAGES 11 & 22
5300-HT2
ODC0S-I1W
Occupancy Sensors
PAGE 5 PAGE 5 PAGE 5
PAGES 6 & 7 PAGES 9 & 10 PAGES 11 & 12
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 3
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
2
H
o
s
p
i
t
a
l

G
r
a
d
e

D
e
v
i
c
e

T
e
s
t
i
n
g
Hospital Grade Testing
Cord Pull Test
The cord must remain securely fastened after
straight pulls of 30 pounds, and rotating pulls
(in a 3-inch circle) of 10 pounds for two hours.
Displacement of conductors, insulation, and
outer jacket of the exible cord AWG 18 SVT
shall not exceed 1/32 inch. There shall be no
cuts, rips, or tears in cord insulation.
Heavy-duty cord stress is typical abuse for
industrial plugs and connectors. Leviton
increases the weight in the straight cord pull
test to 175 lbs. with AWG 14 ST and in the
rotating pull test to 20 lbs., ensuring positive
strain relief under industrial conditions.
Mechanical Drop Test
A sample wired plug or connector
is suspended horizontally by its attached cord,
and released so that it impacts a hard wood
surface 45 inches below the point of
suspension--repeated for 1300 cycles. There
shall be no breakage, deformation, or other
damage which would interfere with the func-
tioning of the device.
Impact Test
A wired plug or connector is subjected to
impact from a 10 lb. weight repeatedly
dropped from a height of 18 inches. There
shall be no breakage, deformation or other
effect that may interfere with the function of
the device. Plugs and connectors are sub-
jected to severe impacts in industrial settings.
Therefore, Leviton exceeds the UL require-
ment by dropping the weight from a height of
36 inches.
500 lb. Crush Test
A wired plug or connector is placed between
two steel plates and subjected to a force which
is steadily increased to 500 pounds. There
shall be no breakage, deformation or other
effect that may interfere with the function of the
device. Leviton knows that in real industrial
environments, plugs and connectors are
crushed by forces exceeding 500 lbs. We
perform the crush test with a force of 2500 lbs.
to ensure that our devices withstand the really
heavy hits on the job.
Abrupt Removal of Plug Test
A steel-bodied test plug with brass blades
is inserted into the receptacle. A 10-pound
weight dropped from at least 24 inches
yanks the plug out of the receptacle. This
test is done eight times with the receptacle
rotated into different positions to create the
greatest stress on its face and contact. After
this, the grounding contact must retain a
four ounce, 0.184 diameter grounding pin,
with the receptacle face down, for one
minute. There shall be no breakage of the
receptacle that interferes with the receptacle
function or the integrity of the enclosure. The
receptacle shall maintain the grounding path
integrity through the receptacle.
Ground Pin Retention Test
The grounding contact of the receptacle is
conditioned by 20 insertions with a .204
oversized pin. After conditioning, a 0.184
diameter pin shall be inserted in the ground-
ing contact which shall be capable of sup-
porting at least four ounces for one minute.
4oz.
+
Power Blade Retention Test
A test plug with oversized blades of .075 is
inserted into the current-carrying opening of
the receptacle for 20 conditioning cycles.
After the conditioning cycles, the contact
shall be capable of supporting for one
minute 1
1
/2 lbs. secured to a single .055
thick solid steel blade without holes.
1.5lb. Assembly Security Test
A force of 100 pounds is applied through the slots to the base of the receptacle while the yoke
is supported at its screw mounting positions. There must be no cracking of base or permanent
deformation of yoke.
In addition...
Leviton Hospital Grade receptacles undergo these demanding tests:
Strength of insulating base
Ground contact temperature
Impact test
Ground Contact Resistance
Terminal Strength Test
Resistance of Ground
Fault current
Gripping
Overload
Temperature
Dielectric withstand
Insulation resistance
Assembly security
Receptacle ground contact
Horsepower
Testing For Hospital Grade Listing Of
Plugs, Connectors, and Receptacles Includes:
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 4
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
Wiring Devices
1. What are the requirements for
receptacles in General Care Patient
Bed Locations?
I
NEC Article 517.18 (B)
Must be hospital grade and have a
permanent means of identication.
Must have a minimum of four receptacle
outlets.
2. What are the requirements for
receptacles in Pediatric Locations?
I
NEC Article 517.18 (C)
Must be hospital
grade and have a
permanent means of
identication.
Must be listed as
Tamper Resistant
3. What are the requirements for
receptacles in Critical Care Patient
Bed locations?
I
NEC Article 517.19 (B)(1)
Must be identied as hospital grade
with a permanent indicator.
Must have a minimum of six receptacle
outlets.
4. True or False: Receptacles supplied by
the emergency power system shall have
distinctive color or marking
as to be readily identiable.
True.
I
NEC Article 517.41 (E)
and NFPA 99, 3-5.2.2.4
Requires receptacles on
the emergency circuit to be
readily identied.
Device color or wall plate
ID.
5. What are the requirements for
receptacles and xed equipment
installed in wet locations?
I
NEC Article 517.20 (A)
All receptacles and xed equipment
within the area of the wet location shall
have ground-fault circuit-interrupter
protection for personnel
if interruption under
fault conditions can
be tolerated. If served
by an isolated power
system, ground fault
circuit interrupter
protection is not required.
GFCI protection is not required for
receptacles installed in critical care
areas where the toilet and basin are
installed within the patient room.
6.What are the testing and maintenance
requirements for electrical receptacles
in health care facilities?
I
NFPA 99, Chapter 3-3 Section 3-3.3.3
Visual integrity, ground continuity,
polarity and ground
blade retention
force.
I
Chapter 3-3
Section 3-3.4.2.3
Testing shall be
performed after
initial installation,
replacement or
servicing. Additional
testing shall be performed at intervals
dened by documented performance
data.
Exception: Receptacles not listed as
hospital grade shall be testing at intervals
not exceeding 12-months.
F
r
e
q
u
e
n
t
l
y

A
s
k
e
d

Q
u
e
s
t
i
o
n
s
3
Frequently Asked Questions
Health Care Facilities Code
and Application Related Questions
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 5
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
4
F
r
e
q
u
e
n
t
l
y

A
s
k
e
d

Q
u
e
s
t
i
o
n
s
Frequently Asked Questions
1. How does a surge protector work?
I
A Surge Protector, sometimes called
a TVSS (transient voltage surge
suppressor); Diverts surge currents away
from equipment by creating a low
impedance path to ground.
I
Typical components
include:
MOV: Metal-Oxide
Varistor
SAD: Silicon
Avalanche Diodes
Gas Tubes
LCR lters
2. How do surges enter a building?
I
Surges Enter A System In Two Ways:
Conducted (Directly On Lines Entering
or Leaving A System)
Radiated (Indirectly Via Electro-
magnetic Fields)
3. What is IEEEC62.41?
The Institute of Electrical and Electronic
Engineers have developed C62.41 59
to provide recommended guidelines on
surge exposure levels with respect to
location. The standard amplitudes and
wave forms are the basis for testing
surge receptacles.
4. Does the NEC cover installation of
Transient Voltage Surge Suppressors?
I
Yes. NEC Article 285 TVSS Protection
covers short circuit rating and installation
and connection of TVSS or Surge
Protection panels.
5. What are the three basic types of
occupancy sensor technologies?
I
Passive Infrared (PIR) 'Line-of-sight'
device that responds to infrared
changes in a workspace.
I
Ultrasonic devices transmit ultrasonic
frequencies (32kHz-40kHz) and
monitor workspace changes.
'Line-of-sight not required'.
I
Multi-Technology single unit that
combines PIR and Ultrasonic to control
lighting loads in a workspace.
6. Can occupancy sensors save energy
and reduce power bills?
I
Yes. Since lighting
accounts for 50% of the
electricity usage in a typical
commercial or institutional
facility turning those loads
off when not required can
have a considerable impact
on the bottom line.
7. Are adjustments required to make sure
the lights do not go off while the
workspace is occupied?
I
Most commercial grade
occupancy sensors are
self adjusting. After initial
installation the device
monitors occupancy
patterns and automatically
compensates for 'real-time'
usage and sets itself
accordingly.
For the complete line of Power Quality products,
request the Power Quality Product Line Bulletin (C-678A).
For the complete line of Occupancy Sensor Products request the
Occupancy Sensors Product Guide (G-7164).
For the complete line of Lighting Controls products,
request the Lighting Controls Product Catalog (G-6960).
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 6
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands Full
2000V rated
per current
UL 498
5
H
o
s
p
i
t
a
l

G
r
a
d
e

S
t
r
a
i
g
h
t

B
l
a
d
e

R
e
c
e
p
t
a
c
l
e
s
15A 125V&250V;20A125V&250V
Hospital Grade
10 YEAR LIMITED
NEMA 5-15R NEMA 5-20R NEMA 6-15R NEMA 6-20R
Back & Side Wired, Self-Grounding
8210-R 8300-E 8300-SGI 8200-HI 8300-PLW 8300-HLI
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL Fed Spec CSA NOM
WD-6 C-73 498HG WC-596 C22.2 No. 42
#E13399 #E13399 #152105 #057
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMM. I.D.
Brass, hot
Grounding
White,neutral
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -40C to 60C
Ratings are
permanently
marked
on device
#14 - #10 AWG
Max 30C
after 250
cycles of
overload at
200% of
rated current
AC HORSEPOWER RATINGS
15A 125V 15A 250V 20A 125V 20A 250V
.5 1.5 1.0 2.0
FACE HOSP. GRD. HOSP. GRD. HOSP. GRD. HOSP. GRD. HOSP. GRD. HOSP. GRD. HOSP. GRD.
COLOR DUPLEX SLIM DUPLEX TAMPER DUPLEX DUPLEX DUPLEX SINGLE
DUPLEX RESISTANT ILLUMINATED
Brown 8200 8200-H 8200-SG 8200-L 8210
Ivory 8200-I 8200-HI 8200-SGI 8200-HLI 8200-LI 8200-PLI 8210-I
White 8200-W 8200-HW 8200-SGW 8200-HLW 8200-LW 8200-PLW 8210-W
Gray 8200-G 8200-HG 8200-SGG 8200-LGY
Red 8200-R 8200-HR 8200-SGR 8200-HLR 8200-LR 8200-PLR 8210-R
Brown 8300 8300-H 8300-SG 8300-L 8310
Ivory 8300-I 8300-HI 8300-SGI 8300-HLI 8300-LI 8300-PLI 8310-I
White 8300-W 8300-HW 8300-SGW 8300-HLW 8300-LW 8300-PLW 8310-W
Gray 8300-G 8300-HGY 8300-SGG 8300-LGY 8310-G
Red 8300-R 8300-HR 8300-SGR 8300-HLR 8300-LR 8300-PLR 8310-R
Black 8300-E 8300-LE
Almond 8300-LA
1.31
(33.3 mm)
0.82
(20.8 mm)
1.33
(33.7 mm)
1.06
(30 mm)
2
.
3
8

(
6
0
.
3

m
m
)
3
.
2
8

(
8
3
.
3

m
m
)
4
.
0
6

(
1
0
3
.
2

m
m
)
0.85
(21.6 mm)
1.55
(39.5 mm)
1.51
(38.5 mm)
1.31
(33.3 mm)
1.31
(33.3 mm)
2
.
7
7

(
7
0
.
4

m
m
)
2
.
7
6

(
7
0
.
0

m
m
)
1.18
(29.9 mm)
3
.
2
8

(
8
3
.
3

m
m
)
4
.
0
6

(
1
0
3
.
2

m
m
)


2
.
7
7

(
1
0
3
.
2

m
m
)
1.38
(33.7 mm)
0.87
(22.1 mm)
1.12
(28.4 mm)
1.21
(38.4 mm)
0.87
(22.1 mm)
1.31
(33.3 mm)
3
.
2
8

(
8
3
.
3

m
m
)
4
.
0
6

(
1
0
3
.
2

m
m
)
3
.
2
8

(
8
3
.
3

m
m
)
4
.
0
6

(
1
0
3
.
2

m
m
)
LEVITON
1.11
(28.1 mm)
0.88
(22.3 mm)
2
.
7
8

(
7
0
.
6

m
m
)
1.53
(38.9 mm)
3
.
2
8

(
8
3
.
3

m
m
)
4
.
0
6

(
1
0
3
.
2

m
m
)
1.31
(33.3 mm)
8200, 8300, 8200-PL,
8300-PL, 8400, 8600
8200-H, 8300-H
8200-HL, 8300-HL 8210, 8310 8200-SG
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
8400
20A 250V, NEMA 6-20R
15A 250V, NEMA 6-15R
FACE HOSP. GRD.
COLOR DUPLEX
Brown 8600
Ivory 8600-I
White
Gray
Red
Brown 8400
Ivory 8400-I
White
Gray
Red
Black
w/Green LED Power Status
Indicator
8300-L
Midway 302/304 non-magnetic stainless
steel wallplates provide more coverage of
wall openings to conceal imperfections that
might occur during sheetrock installation.
w/6 Wire Leads
15A 125V, NEMA 5-15R
20A 125V, NEMA 5-20R
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 7
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
6
H
o
s
p
i
t
a
l

G
r
a
d
e

S
t
r
a
i
g
h
t

B
l
a
d
e

I
s
o
l
a
t
e
d

G
r
o
u
n
d

R
e
c
e
p
t
a
c
l
e
s
15A 125V;20A125V
Hospital Grade
10 YEAR LIMITED
NEMA 5-15R NEMA 5-20R
NYLON WALLPLATES 302 STAINLESS STEEL WALLPLATES WEATHER RESISTANCE
COVERS DIE-CAST ZINC
ISOLATED GROUND ISOLATED GROUND
80703-IG 80703-RE 80704-IG 80716-I 84004-40 84003-40 84016-40 84005-40 4925-2 4970
FOR ADDITIONAL WALLPLATE OPTIONS SEE IPD 2.05 CATALOG
Back & Side Wired
8200-IGB
Split Circuit Not Available
1254-IGW 8490-IGG 8200-LIG 8210-IG
4-in-1 Side Wired
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL Fed Spec CSA NOM
WD-6 C-73 498HG WC-596 C22.2 No. 42
#E13399 #E13399 #152105 #057
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMM. I.D.
Brass, hot
Grounding
White,neutral
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -40C to 60C
Ratings are
permanently
marked
on device
#14 - #10 AWG
Max 30C
after 250
cycles of
overload at
200% of
rated current
AC HORSEPOWER RATINGS
15A 125V 15A 250V 20A 125V 20A 250V
.5 1.5 1.0 2.0
15A 125V, NEMA 5-15R
20A 125V, NEMA 5-20R
EMERGENCY
2
.
7
7

(
7
0
.
4

m
m
)
0.87
(22.1 mm)
1.12
(28.4 mm) 1.55
(39.5 mm)
1.31
(33.3 mm)
3
.
2
8

(
8
3
.
3

m
m
)
4
.
0
6

(
1
0
3
.
2

m
m
)
1.31
(33.3 mm)
0.82
(20.8 mm)
1.33
(33.7 mm)
1.06
(30 mm)
2
.
3
8

(
6
0
.
3

m
m
)
3
.
2
8

(
8
3
.
3

m
m
)
4
.
0
6

(
1
0
3
.
2

m
m
)

2
.
7
7

(
1
0
3
.
2

m
m
)
1.38
(33.7 mm)
0.87
(22.1 mm)
1.12
(28.4 mm)
1.31
(33.3 mm)
3
.
2
8

(
8
3
.
3

m
m
)
4
.
0
6

(
1
0
3
.
2

m
m
)
8200-IG, 8300-IG 8210-IG, 8310-IG 8200-LIG, 8300-LIG
FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE
COLOR IG DUPLEX IG 4-IN-1 IG 4-IN-1 SURGE IG DUPLEX IG SINGLE
Refer to page 7 for Terminal Accom. & Device Drawings
Brown 8200-IGB
Ivory 8200-IGI 1254-IGI
White 8200-IGW 1254-IGW 8480-IGW
Gray 8200-IGG 8480-IGG
Red 8200-IGR
Orange 8200-IG 1254-IG 8480-IG 8200-LIG 8210-IG
Brown 8300-IGB
Ivory 8300-IGI 21254-IGI
White 8300-IGW 21254-IGW 8490-IGW
Gray 8300-IGG 8490-IGG
Red 8300-IGR
Orange 8300-IG 21254-IG 8490-IG 8300-LIG 8310-IG
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands Full
2000V rated
per current
UL 498
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
w/6 Ground Lead w/6 Ground Lead
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 8
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
Split Circuit Not Available
8490-IGG
Split Circuit Not Available
8490-R
7
H
o
s
p
i
t
a
l

G
r
a
d
e

F
o
u
r
-
I
n
-
O
n
e

S
t
r
a
i
g
h
t

B
l
a
d
e

R
e
c
e
p
t
a
c
l
e
s
10 YEAR LIMITED
15A 125V, NEMA 5-15R
20A 125V, NEMA 5-20R
4.50 (114.3 mm) square
3.38 (85.9 mm) 0.68 (17.1 mm)
0.25 (6.4 mm)
3
.
3
8

(
8
5
.
9

m
m
)
1.15 (29.2mm)
4.80 (121.9 mm) square
2.75 (69.8 mm)
3.38 (85.9 mm
1.75
(44.4 mm)
1.73
(43.9 mm)
0.31
(7.9 mm)
0.42 (10.7 mm)
0.12 (3.2 mm)
3
.
2
8

(
8
3
.
4

m
m
)
3
.
3
8

(
8
5
.
9

m
m
)
2
.
7
3

(
6
9
.
3

m
m
)
4
.
2
5

(
1
0
7
.
9

m
m
)
DIMENSIONS APPLY TO ALL
FOUR-IN-ONE RECEPTACLES 4254 3254
Four-In-One Adapter Plates
Four-In-One Portable Boxes
PLATE ADAPTER
COLOR PLATE
Brown 3254
Ivory 3254-I
White 3254-W
Gray 3254-GY
Red 3254-R
Black 3254-E
Orange 3254-OR
Blue 3254-BLU
Mounts
Directly
Single-Gang
4 Square
4 Octagon
Mounts
with
Adapter
Plate
4
11
/16Square
2-Gang
4.50 (114.3 mm) square
3.38 (85.9 mm) square
3
.
2
8

(
8
3
.
3

m
m
)

s
q
u
a
r
e
4 knockouts
.90
(22.9 mm)

0.66
(16.8)
FeedThru Wire Hole
Portable boxes are not UL Listed.
15A 125V; 20A 125V
Hospital Grade
NEMA 5-15R NEMA 5-20R
1254-HW 1254-IG
Accepts #16/3 AWG Type SJ to #12/3 AWG
Type SO COPPER Only.
Side Wired
For clamping and
performance data refer
to page 8.
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL Fed Spec CSA NOM
WD-6 C-73 498HG WC-596 C22.2 No. 42
#E13399 #E13399 #152105 #057
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMM. I.D.
Brass, hot
Grounding
White,neutral
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -40C to 60C
Ratings are
permanently
marked
on device
#14 - #10 AWG
Max 30C
after 250
cycles of
overload at
200% of
rated current
AC HORSEPOWER RATINGS
15A 125V 15A 250V 20A 125V 20A 250V
.5 1.5 1.0 2.0
BOX PORTABLE
COLOR BOX
Ivory 4254-I
Gray 4254-GY
Black 4254-E
Orange 4254-OR
Blue 4254-BLU
Yellow 4254-Y
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands Full
2000V rated
per current
UL 498
FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE
COLOR IG IG, SURGE SURGE
Brown 1254-H
Ivory 1254-HI 1254-IGI 8480-IGI 8480-I
White 1254-HW 1254-IGW 8480-IGW 8480-W
Gray 8480-IGG
Red 1254-HR 8480-R
Black
Orange 1254-IG 8480-IG
Blue 8480-IGB
Brown 21254-H
Ivory 21254-HI 21254-IGI 8490-IGI 8490-I
White 21254-HW 21254-IGW 8490-IGW 8490-W
Gray 21254-HGY 8490-IGG
Red 21254-HR 8490-R
Black
Orange 21254-IG 8490-IG
Blue 8490-IGB
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 9
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
8
H
o
s
p
i
t
a
l

G
r
a
d
e

A
C

D
e
c
o
r
a

S
u
r
g
e

R
e
c
e
p
t
a
c
l
e
s
15A 125V; 20A 125V
Hospital Grade
10 YEAR LIMITED
NEMA 5-15R NEMA 5-20R
1.47 (37.3 mm)
2
.
7
0

(
6
8
.
6

m
m
)
3
.
8
1

(
9
6
.
8

m
m
)
3
.
2
8

(
8
3
.
3

m
m
)
1.70 (43.2 mm)
SURGE RECEPTACLES
Back & Side Wired
8380 8280-IGO 8281-IGI Back View 8381-GY
15A 125V, NEMA 5-15R
20A 125V, NEMA 5-20R
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL Fed Spec CSA NOM
WD-6 C-73 498HG WC-596 C22.2 No. 42
#E13399 #152105 #057
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMM. I.D.
Brass, hot
Grounding
White,neutral
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -40C to 60C
Ratings are
permanently
marked
on device
#14 - #10 AWG
Max 30 C
after 250
cycles of
overload at
200% of
rated current
AC HORSEPOWER RATINGS
15A 125V 15A 250V 20A 125V 20A 250V
.5 1.5 1.0 2.0
OPERATING MAXIMUM MAXIMUM MAXIMUM EMI-RFI NOISE
FREQUENCY CONTINUOUS SINGLE-PULSE SINGLE-PULSE REJECTION
OPERATING (10x1000s) (8x20s) @ 50 Ohms
VOLTAGE (MCOV) Joules L-N/L-G/N-G 500K - 30MHz
50, 60Hz 150V rms 720 24kA/12kA/12kA -30dB
PERFORMANCE DATA
UL1449 SUPPRESSED
VOLTAGE RATINGS (SVR)
Assigned at 6" lead length with 6kV/500A
impulse in accordance with UL1449 (2nd Ed.)
400/400/400Vpk
CLAMPING PERFORMANCE
FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE
COLOR SURGE, DUPLEX SURGE, SINGLE IG, SURGE, DUPLEX IG, SURGE, SINGLE
Brown 8280
Ivory 8280-I 8280-IGI 8281-IGI
White 8280-W 8280-IGW 8281-IGW
Gray 8280-IGG
Red 8280-R
Blue 8280-B 8280-IGB
Black
Orange 8280-IGO 8281-IGO
Almond 8280-IGA 8281-IGA
Brown 8380 8381
Ivory 8380-I 8381-I 8380-IGI 8381-IGI
White 8380-W 8380-IGW 8381-IGW
Gray 8380-GY 8381-GY 8380-IGG
Red 8380-R 8381-R 8380-IGR
Black
Blue 8380-B 8380-IGB 8381-IGB
Orange 8380-IGO 8381-IGO
Almond
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands Full
2000V rated
per current
UL 498
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
Indicator Light,
Audible Alarm
Indicator Light,
Audible Alarm
Indicator Light,
Audible Alarm
Indicator Light,
Audible Alarm
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 10
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
SCREWLESS NYLON 302 STAINLESS STEEL
SNAP-ON WALLPLATES WALLPLATES WALLPLATES
15A 125V, NEMA 5-15R
80301-I 80309-I 80401-NE 80409-NE 84409-40 84411-40
Meets or Exceeds
UL, 2006 Requirements
Smart Lock

GFCI Prevents
Reset in Case of Line-Load
Reverse Wiring
Greater Protection Against Loss
of Ground Fault Protection Due to
Surges, Abuse and Overvoltages
Device Prevents Reset If Its
Protective Function Has Been
Compromised
FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSP. GRD. SMARTLOCK

COLOR DUPLEX DUPLEX IG DUPLEX DUPLEX w/ LED - GFCI DUPLEX


TAMPER-RESISTANT Self-Grounding Does Not Apply w/ LOCKOUT
Brown 16262-SG 7599-HG
Ivory 16262-HGI 16262-SGI 16262-IGI 16262-PLI 7599-HGI
White 16262-HGW 16262-SGW 16262-IGW 16262-PLW 7599-HGW
Gray 16262-HGG 16262-SGG 16262-IGG 7599-HGG
Red 16262-HGR 16262-SGR 16262-IGR 16262-PLR 7599-HGR
Black
Blue 16262-IGB
Orange 16262-IG
Almond 7599-HGA
Light
Almond 7599-HGT
9
H
o
s
p
i
t
a
l

G
r
a
d
e

A
C

D
e
c
o
r
a

P
l
u
s

R
e
c
e
p
t
a
c
l
e
s
15A 125V
Hospital Grade
10 YEAR LIMITED
Back & Side Wired, Self-Grounding
4
.
0
6

(
1
0
3
.
2

m
m
)
3
.
8
1

(
9
6
.
8

m
m
)
3
.
2
8

(
8
3
.
3

m
m
)
0.88 (22.4 mm)
1.52
(38.7 mm)
1.14
(29.0 mm)
1.31
(33.3 mm)
2
.
7
8

(
7
0
.
6

m
m
)
16262 & 16362 SERIES 7599-HG SERIES
NEMA 5-15R
16262-HGR 16262-SGW 16262-IG 16262-PLR
7599-HGR
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL Fed Spec CSA NOM
WD-6 C-73 498HG WC-596 C22.2 No. 42
#E13399 #152105 #057
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMM. I.D.
Brass, hot
Grounding
White,neutral
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -40C to 60C
Ratings are
permanently
marked
on device
#14 - #10 AWG
Max 30C
after 250
cycles of
overload at
200% of
rated current
AC HORSEPOWER RATINGS
15A 125V 15A 250V 20A 125V 20A 250V
.5 1.5 1.0 2.0
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands Full
2000V rated
per current
UL 498
Note: This device
meets UL Fed
Spec WC-596
requirements
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
w/Green LED Power
Status Indicator
1.7 (43.2 mm)
1.12 (28 mm)
2
.
7

(
6
8
.
6

m
m
)
4
.
2
1

(
1
0
6
.
9
3

m
m
)
C L A S S A
L E V I T O N
G
F
C
I
C
L
A
S
S

1
5
A
M
P
1
2
5
V

1.53 (38.9 mm)
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 11
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
20A 125V, NEMA 5-20R
SCREWLESS NYLON 302 STAINLESS STEEL
SNAP-ON WALLPLATES WALLPLATES WALLPLATES
80301-I 80309-I 80401-NE 80409-NE 84409-40 84411-40
Meets or Exceeds
UL, 2006 Requirements
SmartLock

GFCI Prevents
Reset in Case of Line-Load
Reverse Wiring
Greater Protection Against Loss
of Ground Fault Protection Due to
Surges, Abuse and Overvoltages
Device Prevents Reset If Its
Protective Function Has Been
Compromised
10
H
o
s
p
i
t
a
l

G
r
a
d
e

A
C

D
e
c
o
r
a

P
l
u
s

R
e
c
e
p
t
a
c
l
e
s
10 YEAR LIMITED
15A 125V
Hospital Grade
NEMA 5-20R
4
.
0
6

(
1
0
3
.
2

m
m
)
3
.
8
1

(
9
6
.
8

m
m
)
3
.
2
8

(
8
3
.
3

m
m
)
0.88 (22.4 mm)
1.52
(38.7 mm)
1.14
(29.0 mm)
1.31
(33.3 mm)
2
.
7
8

(
7
0
.
6

m
m
)
Back & Side Wired, Self-Grounding
16362-HGI 16362-IG 16362-PLR
MECHANICAL
TERMINAL TERMINAL PRODUCT
I.D. ACCOMM. I.D.
Brass, hot
Grounding
White,neutral
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -40C to 60C
Ratings are
permanently
marked
on device
#14 - #10 AWG
Max 30C
after 250
cycles of
overload at
200% of
rated current
AC HORSEPOWER RATINGS
15A 125V 15A 250V 20A 125V 20A 250V
.5 1.5 1.0 2.0
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL Fed Spec CSA NOM
WD-6 C-73 498HG WC-596 C22.2 No. 42
#E13399 #152105 #057
16262 & 16362 SERIES 7899-HG SERIES
7899-HGW
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands Full
2000V rated
per current
UL 498
FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSP. GRD. SMARTLOCK

COLOR DUPLEX IG DUPLEX DUPLEX w/ LED - GFCI DUPLEX w/ LOCKOUT


Self-Grounding Does Not Apply Meets 2003 UL Requirements
Brown 7899-HG
Ivory 16362-HGI 16362-IGI 16362-PLI 7899-HGI
White 16362-HGW 16362-IGW 16362-PLW 7899-HGW
Gray 16362-HGG 16362-IGG 7899-HGG
Red 16362-HGR 16362-IGR 16362-PLR 7899-HGR
Black
Blue 16362-IGB
Orange 16362-IG
Almond 7899-HGA
Light
Almond 7899-HGT
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
1.7 (43.2 mm)
1.12 (28 mm)
2
.
7

(
6
8
.
6

m
m
)
4
.
2
1

(
1
0
6
.
9
3

m
m
)
C L A S S A
L E V I T O N
G
F
C
I
C
L
A
S
S

2
0
A
M
P
1
2
5
V

1.53 (38.9 mm)
w/Green LED Power
Status Indicator
Note: This device
meets UL Fed
Spec WC-596
requirements
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 12
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
30C max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
11
H
o
s
p
i
t
a
l

G
r
a
d
e

S
t
r
a
i
g
h
t

B
l
a
d
e

P
l
u
g
s

&

C
o
n
n
e
c
t
o
r
s
,

P
o
w
e
r

S
t
r
i
p
s

15A 125; 20A 125&250V
Hospital Grade
10 YEAR LIMITED
8315-CT 8315-CAT 8319-C
20A 125V, NEMA 5-20P AND 5-20R, 2-P 3-W
20A 250V, NEMA 6-20P AND 6-20R, 2-P 3-W
1.39 (35.3 mm)
1.49 (37.9 mm)
2
.
7
6

(
7
0
.
1

m
m
)
1.53 ( 38.9 mm)
1.39 ( 35.3 mm)
1
.
9
8

(
5
0
.
4

m
m
)
0.97 (24.7 mm)
1.15 (29.2 mm) dia.
1.05 (26.8 mm)
1
.
5
7

(
3
9
.
9

m
m
)

PLUGS CONNECTORS ANGLE PLUGS
15A 125V, NEMA 5-15P AND 5-15R, 2-P 3-W
NEMA 5-15P NEMA 5-15R NEMA 5-20P` NEMA 5-20R NEMA 6-20P NEMA6-20R
MECHANICAL
TERMINAL TERMINAL PRODUCT CORD GRIP
I.D. ACCOMM. I.D. RANGE
Brass, hot
Grounding
White,neutral
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL Fed Spec CSA NOM
WD-6 C-73 498 Listed WC-596 C22.2 No. 42

#E13393 #LR-406 #057
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -40C to 60C
Ratings &
NEMA I.D.
permanently
marked on device
#18 - #10
AWG
.245" - .700"
TYPE PLUG CONNECTOR ANGLE PLUG
Black & White 8215-C 8219-C
Transparent 8215-CT 8219-CT 8215-CAT
Lighted Transparent 8215-PLC 8219-PLC
Black & White 8315-C 8319-C
Transparent 8315-CT 8319-CT 8315-CAT
Lighted Transparent 8315-PLC 8319-PLC
Transparent 8415-CAT
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands Full
2000V rated
per current
UL 498
5300-HT2
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
6-HG, TAMPER-RESISTANT
OUTLETS & HOSP. GRADE
LIGHTED
TRANSPARENT PLUG
5300-HT2
20A 120V NEMA
5-20 P, Plug & 5-20R
Receptacles 2-P 3-W
SURGE SUPPRESSOR PLUG
STRIP w/ MULTI-STAGE
PROTECTION
CORD LENGTH
6'
(without switch)
5300-HTS
6-HG, TAMPER-RESISTANT
OUTLETS & HOSP. GRADE
LIGHTED
TRANSPARENT PLUG
5300-HTS (6')
5300-H15 (15')
15A 120V
NEMA 5-15P & 5-15R
2-P 3-W
SURGE SUPPRESSOR PLUG
STRIP w/ MULTI-STAGE
PROTECTION
CORD LENGTHS
6' and 15'
(without switch)
See Additional Strips
Page 22
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 13
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
12
H
o
s
p
i
t
a
l

G
r
a
d
e

P
l
u
g
s

&

C
o
n
n
e
c
t
o
r
s
15A 125V & 250V; 20A 125V & 250V
Hospital Grade
10 YEAR LIMITED
GR
W Y
X
GR
NON-NEMA NON-NEMA
23001-HG 23000-HG 23004-HG
20A 125V, Non-NEMA, 2-P 3-W, Grounding
UL Listed for "HOSPITAL USE ONLY" applications in non-hazardous areas.
NEMA 5-15P NEMA 5-15R
15A 250V, 2-P 3-W, Grounding
20A 125V, 2-P 3-W, Grounding
20A 250V, 2-P 3-W, Grounding
NEMA 6-15P NEMA 6-15R
NEMA 5-20P NEMA 5-20R
NEMA 6-20P NEMA 6-20R
PYTHON PYTHON 23001-HG 23004-HG
PLUGS CONNECTORS
1
.
8
1

(
4
6
.
0

m
m
)

1.40 (35.7 mm) 1.50 (38.1 mm)
2
.
5
0

(
6
4
.
0

m
m
)

1.41 (35.7 mm)
1.69 (42.9 mm)
3
.
6
3

(
9
2
.
1

m
m
)

1.69 (42.9 mm)
3
.
2
5

(
8
2
.
6

m
m
)

2
.
3
1

(
5
8
.
7

m
m
)

1.50 (38.1 mm)
8256-V 8259-V 8456-V
PLUGS AND CONNECTORS
TM
84004-40
MECHANICAL
TERMINAL TERMINAL PRODUCT CORD GRIP
I.D. ACCOMM. I.D. RANGE
Brass, hot
Grounding
White,neutral
STANDARDS & CERTIFICATIONS
NEMA ANSI UL UL Fed Spec CSA NOM
WD-6 C-73 498 Listed WC-596 C22.2 No. 42

#E13393 #LR-406 #057
30C max at full
rated current
after 50 cycles
overload at
150% rated
current for both
AC and DC per
UL 498
ENVIRONMENTAL
FLAMMABILITY OPERATING TEMP.
Rated V-2 per UL 94 -40C to 60C
Ratings &
NEMA I.D.
permanently
marked on device
#18 - #10
AWG
.245" - .700"
15A 125V, 2-P 3-W, Grounding
POWER INTERRUPTING LOCKING LOCKING LOCKING 302 NON-NEMA
DEVICES PLUG CONNECTOR FLUSH RECEPTACLE STAINLESS STEEL
w/ THERMOSET BODY WALLPLATE
Gray & Black 23004-HG 23001-HG 23000-HG
COLOR STRAIGHT BLADE STRAIGHT BLADE NEMA
PYTHON PLUG PYTHON CONNECTOR
White 8256-V 8259-V
White
8656-V 8659-V
White
8356-V 8359-V
White
8456-V 8459-V
ELECTRICAL
DIELECTRIC CURRENT TEMP.
VOLTAGE INTERR. RISE
Withstands Full
2000V rated
per current
UL 498
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 14
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
P
o
w
e
r

Q
u
a
l
i
t
y

D
e
v
i
c
e
s

-

S
u
r
g
e

P
r
o
t
e
c
t
i
v
e

P
a
n
e
l

M
o
u
n
t
s
13
Panel Mounted Devices
74000 & 75000 Series - For Industrial & Commercial Environments
Diagnostic Capabilities:
Monitors the status of each phase
Display will indicate Fault, Alert, and Protection status.
Functions include a surge event counter, amplitude measurement,
date and time stamping of the event.
Events are stored and are recallable and downloadable by the user
Normal Operations:
Green indicator lights illuminate when the panel status is OK. A fault condition is indicated when up to 3 indicators are no longer illuminated
Yellow indicator light will illuminate and audible alarm will sound when one of the fuses in the surge module opens due to surge activity
The percentage of protection in that module will ash on the screen (i.e., 75% protection when 1 fuse is open)
Red indicator light will illuminate and audible alarm will sound when protection level is at 50% or less
Arrow buttons allow user to view surge event history on each line by scrolling through data
Information is easily downloadable via RS-232 port using the program Hyperterminal that comes standard on any Windows operating software
(see instruction sheet for detailed instructions)
74000 & 75000 Series
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com/powerquality
10 YEAR LIMITED
74120-7M3
SPECIFICATIONS & FEATURES
74000 & 75000 SERIES
Provides Seven Mode Protection.
User replaceable modules
Real-time diagnostics monitor power
and suppression status for each
mode
Surge magnitude, time, and date is
provided for each surge event
Surge event history downloadable
for storage via RS-232 connection
AC Sine Wave Tracking
Optically isolated dry contacts
UL 1449 2
nd
Edition Listed
ENVIRONMENTAL
STORAGE TEMPERATURE
-20C to 85C
OPERATING TEMPERATURE
-10C to 60C
STANDARDS & CERTIFICATIONS
ANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449
#E146315
CSA
#LR-94773
DESCRIPTION CATALOG NO. VOLTAGE RATING MODULE NO.
3WYE (4-Wire + Ground)
7-Mode, 3 WYE, 4-Wire + Ground 74120-7M3 120/208V AC (7) HC120-M40
7-Mode, 3 WYE, 4-Wire + Ground 74277-7M3 277/480V AC (7) HC277-M40
7-Mode, 3 WYE, 4-Wire + Ground 75120-7M3 120/208V AC (7) HC120-M53
7-Mode, 3 WYE, 4-Wire + Ground 75277-7M3 277/480V AC (7) HC277-M53
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 15
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
Panel Mounted Devices
74000 & 75000 Series - For Industrial & Commercial Environments
14
P
o
w
e
r

Q
u
a
l
i
t
y

D
e
v
i
c
e
s

-


S
u
r
g
e

P
r
o
t
e
c
t
i
v
e

P
a
n
e
l

M
o
u
n
t
s
US C
N-G
Line 2
Line 1
Line 3
SURGE COUNTER
1
5
.
8

(
4
0
1
m
m
)
8.33 (211.6mm)
7.48 (190mm)
19.71 (500.3mm)
74000 & 75000 SERIES
74000 & 75000 Series
Diagnostic display panel on the 74000 and
75000 Series uses LED display to indicate
Fault, Alert, and Protection status.
75000 Series modules are designed with
four arrester grade MOV's each rated for
80,000 Amps, 8x20us Impulse. Each mod-
ule is tested to maximum levels of surge
current withstand at an independent labo-
ratory.
Large-diameter MOV's, 40mm on 74000
Series panels and 53mm on the 75000
Series, are individually thermal fused for
over-current protection.
CATALOG NO. MCOV UL 1449 (2
nd
Ed) IMPULSE MAX.SURGE CURRENT in KA NOISE
6kV/500A (test w/ 8x20us wave) REJECTION
L-N L-G N-G L-N + L-G = per Phase
74120-7M3 150V AC 400 400 400 200 200 400 -40 dB
(@ 5K-100MHz)
74277-7M3 320V AC 800 800 800 200 200 400 -40 dB
(@ 5K-100MHz)
75120-7M3 150V AC 400 400 400 320 320 640 20-40 dB
(@ 5K-100MHz)
75277-7M3 320V AC 800 800 800 320 320 640 20-40 dB
(@ 5K-100MHz)
10 YEAR LIMITED
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com/powerquality
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 16
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
ENVIRONMENTAL
FLAMMABILITY
P
o
w
e
r

Q
u
a
l
i
t
y

D
e
v
i
c
e
s

-


S
u
r
g
e

P
r
o
t
e
c
t
i
v
e

P
a
n
e
l

M
o
u
n
t
s
15
Panel Mounted Devices
57000 Series - For Service Entrance or Branch Panels
10 YEAR LIMITED
Replacement Modules for Superior Protection
The heart of the Cat. No. 57000 group is the powerful Replacement Module equipped with
extremely effective hybrid multi-component suppression circuitry. Six different module variants are
available to suit a range of commonly available North American AC line-voltage congurations.
57120-M3
Type 1
57120-CM3
Type 12
STANDARDS & CERTIFICATIONS
SPECIFICATIONS & FEATURES
57000 SERIES
Available with NEMA 12 enclosure
Flush mount collar included with most
units
Dry contacts for remote monitoring
(NO-C-NC)
Modular design allows for easy
replacement of modules
Features Sine-Wave Tracking and
Redundant Protection
UL 1449 2
nd
Edition Listed
STORAGE TEMPERATURE
-20C to 85C
OPERATING TEMPERATURE
-10C to 60C
UL 945-V
Flame Retardant Thermoplastic
(Front Bezel)
ANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449
#E146315
NEC
200 KAIC Rated per Article 285
CSA
#LR-94773
DESCRIPTION WITHOUT SURGE COUNTER WITH SURGE COUNTER VOLTAGE RATING MODULE NO.
3WYE (4-Wire + Ground)
3WYE, 4-Wire & Ground 57120-M3 57120-CM3 120/208V AC (3) 120
(1) 8120-GN
3WYE 7-Mode, Integral 57120-M3S 57120-C3S 120/208V AC (3) 120-M3S
Disconnect, 4-Wire & Ground (1) 8120-GN
3WYE, 4-Wire & Ground 57220-IM3 220/380V AC (3) 220
(1) 8250-GN
3 Delta, 3-Wire & Ground 57240-DM3 240V AC (3) 7240
3WYE, 4-Wire & Ground 57277-M3 57277-CM3 277/480V AC (3) 7277
(1) 8320-GN
3WYE 7-Mode, Integral 57277-M3S 57277-C3S 277/480V AC (3) 7277-M3S
Disconnect, 4-Wire & Ground (1) 8320-GN
3WYE, 4-Wire & Ground 57346-M3 346/600V AC (3) 7347
(1) 8385-GN
3WYE, 4-Wire & Ground 57347-M3S 347/600V AC (3) 7346
(1) 8385-GN
3 Delta, 3-Wire & Ground 57480-DM3 480V AC (3) 7480
3 Delta, 3-Wire & Ground 57600-DM3 600V AC (3) 7600
57000 Series
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com/powerquality
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 17
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
Panel Mounted Devices
57000 Series - For Service Entrance or Branch Panels
16
P
o
w
e
r

Q
u
a
l
i
t
y

D
e
v
i
c
e
s

-


S
u
r
g
e

P
r
o
t
e
c
t
i
v
e

P
a
n
e
l

M
o
u
n
t
s
10 YEAR LIMITED
1.53
(38.9 mm) 3.28 (83.3 mm)
4
.
4
1

(
1
1
2
.
0

m
m
)
HIGH VOLTAGE
Haute tension
DANGER
5.00"
(127.0 mm)
10.31" (261.9 mm)
7.50" (190.5 mm)
3
.
5
0
"

(
8
8
.
9

m
m
)
1
4
.
9
"

(
3
6
0
.
4

m
m
)
57000 SERIES 57000-M3S 52000-RS
2
0
.
0
0

(
5
0
8
.
0

m
m
)

16.00 (406.4 mm) 6.80


(172.7 mm)
8.02
(203.7 mm)
57000 Series panels Shown with 52000-RS Remote Supervisor, features easy-to-install replaceable modules.
CATALOGNO. MCOV UL 1449 (2
nd
Ed) IMPULSE MAX.SURGE CURRENT in KA NOISE
6kV/500A (test w/ 8x20us wave) REJECTION
L-N L-G N-G L-L L-N + L-G = per Phase
57120-M3 150V AC 400 800 400 800 150 150 -20 to -40 dB
57120-CM3 (@ 5K-10MHz)
57120-M3S 150V AC 400 500 400 700 100 100 200 -20 to -40 dB
57120-C3S (@ 5K-10MHz)
57220-IM3 250V AC 600 1200 600 1200 150 150 -20 to -40 dB
(@ 5K-10MHz)
57240-DM3 250V AC 700 -20 to -40 dB
(@ 5K-10MHz)
57277-M3 320V AC 800 1800 800 1800 150 150 -20 to -40 dB
57277-CM3 (@ 5K-10MHz)
57277-M3S 320V AC 900 1000 800 1500 100 100 200 -20 to -40 dB
57277-C3S (@ 5K-10MHz)
57346-M3 385V AC 1000 2000 1000 2000 150 150 -20 to -40 dB
(@ 5K-10MHz)
57347-M3S 390V AC 1000 1000 1000 2000 100 100 200 -20 to -40 dB
(@ 5K-10MHz)
57480-DM3 550V AC 1500 -20 to -40 dB
(@ 5K-10MHz)
57600-DM3 680V AC 1800 -20 to -40 dB
(@ 5K-10MHz)
57000 Series
L-L: 150
L-L: 150
L-L: 150
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com/powerquality
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 18
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
Remote Supervisor Provides Clear Indication of Protection Status
All Leviton Panel mounted SPDs are equipped with real-time diagnostics that indicate protection
status. However, when these units are mounted in electrical closets, or other out-of-the-way locations,
a diagnostic alert might not be seen or heard for some time.
The 52000-RS Remote Supervisor can relay protection failure or power interruption warnings from
one or more Leviton panel-mounted SPDs. Warnings are provided by an optically coupled sensor and
data lines comprising up to 5000 feet of #20 or #22 twisted-pair wiring. One Remote Supervisor can
monitor up to six panel-mounted SPDs. The Remote Supervisor provides both a visual and audible
alert, which can be silenced at the press of a button. The unit is equipped with a test circuit, and
designed for surface mounting. It draws power from any 120V source through a six-foot line cord.
52000-RS
ENVIRONMENTAL
FLAMMABILITY
P
o
w
e
r

Q
u
a
l
i
t
y

D
e
v
i
c
e
s

-


S
u
r
g
e

P
r
o
t
e
c
t
i
v
e

P
a
n
e
l

M
o
u
n
t
s
17
Panel Mounted Devices
52000 Series - For Industrial & Commercial Environments
10 YEAR LIMITED
DESCRIPTION WITHOUT SURGE COUNTER WITH SURGE COUNTER VOLTAGE RATING MODULE NO.
Single Phase, 2-Wire & Ground 52120-M1 120V AC (1) 2120
(1) 8120-GN
Single Phase, 3-Wire & Ground 52120-M2 52120-CM2 120/240V AC (2) 2120
(Home Automation Model) (52120-M2H) (1) 8120-GN
3WYE, 4-Wire & Ground 52120-M3 52120-CM3 120/208V AC (3) 2120
(Without Enclosure) (52120-B3) (1) 8120-GN
3WYE (International), 52220-IM3 220/380V AC (3) 2220
4-Wire & Ground (1) 8250-GN
3 Delta, 3-Wire & Ground 52240-DM3 240V AC (3) 2240
3WYE, 4-Wire & Ground 52277-M3 52277-CM3 277/480V AC (3) 2277
(1) 8320-GN
3WYE, 4-Wire & Ground 52347-M3 347/600V AC (3) 2347
(1) 8385-GN
3 Delta, 3-Wire & Ground 52480-DM3 480V AC (3) 2480
Split Phase Delta, 52412-DS3 120/240V AC (2) 2120 (120V) &
4-Wire & Ground (1) 2412 (Hi-Leg)
52000 Series
52120-M3
Type 12
52120-CM3
Type 12
STANDARDS & CERTIFICATIONS
SPECIFICATIONS & FEATURES
52000 SERIES
Available with NEMA 12 enclosure
Flush mount collar included with most
units
Dry contacts for remote monitoring
Features Sine-Wave Tracking and
Redundant Protection
UL 1449 2
nd
Edition Listed
STORAGE TEMPERATURE
-20C to 85C
OPERATING TEMPERATURE
-10C to 60C
UL 945-V
Flame Retardant Thermoplastic
(Front Bezel)
ANSI/IEEE Categories A, B, & C
C-62.41 & C-62.45
UL 1449
#E146315
NEC
200 KAIC Rated per Article 285
CSA
#LR-94773
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com/powerquality
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 19
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
Panel Mounted Devices
52000 Series - For Industrial & Commercial Environments
18
P
o
w
e
r

Q
u
a
l
i
t
y

D
e
v
i
c
e
s

-


S
u
r
g
e

P
r
o
t
e
c
t
i
v
e

P
a
n
e
l

M
o
u
n
t
s
10 YEAR LIMITED
HIGH VOLTAGE
Haute tension
DANGER
5.00"
(127.0 mm)
10.31" (261.9 mm)
7.50" (190.5 mm)
3
.
5
0
"

(
8
8
.
9

m
m
)
1
4
.
9
"

(
3
6
0
.
4

m
m
)
52000 SERIES 52000-RS
1.53
(38.9 mm)
3.28 (83.3 mm)
4
.
4
1

(
1
1
2
.
0

m
m
)
52000 Series
CATALOGNO. MCOV UL 1449 (2
nd
Ed) IMPULSE MAX.SURGE CURRENT in KA NOISE
6kV/500A (test w/ 8x20us wave) REJECTION
L-N L-G N-G L-L L-N
52120-M1 150V AC 400 800 400 100 -20 to -40 dB
(@ 5K-10MHz)
52120-M2 150V AC 400 800 400 800 100 -20 to -40 dB
52120-CM2 (@ 5K-10MHz)
52120-M2H 150V AC 400 800 400 800 100 N/A DHC Power
Line Carrier
Compatible
52120-M3 (B3) 150V AC 400 800 400 800 100 -20 to -40 dB
52120-CM3 (@ 5K-10MHz)
52220-IM3 250V AC 600 1200 600 1200 100 -20 to -40 dB
(@ 5K-10MHz)
52240-DM3 L-L: 250V AC 600 100 -20 to -40 dB
(@ 5K-10MHz)
52277-M3 320V AC 800 1800 800 1800 100 -20 to -40 dB
52277-CM3 (@ 5K-10MHz)
52347-M3 420V AC 900 900 100 -20 to -40 dB
L-L: 680 (@ 5K-10MHz)
52480-DM3 550V AC 1500 100 -20 to -40 dB
(@ 5K-10MHz)
52412-DS3 L-L: 250V AC 400 800 400 800 100 -20 to -40 dB
(@ 5K-10MHz)
For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com/powerquality
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 20
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
C
o
m
m
e
r
c
i
a
l

G
r
a
d
e

W
a
l
l

S
w
i
t
c
h
e
s

&

C
e
i
l
i
n
g
-
M
o
u
n
t

O
c
c
u
p
a
n
c
y

S
e
n
s
o
r
s
19
Infrared Occupancy Sensors
Commercial Grade Wall Switches & Ceiling-Mount
Commercial Grade Decora

Wall Switch Infrared Occupancy Sensor (Incandescent and Fluorescent)


Commercial Grade Dual-Relay Decora

Wall Switch Infrared Occupancy Sensors


Adaptive Dual Relay Occupancy Sensors:
Conference Room Mode Both Primary and
Secondary Relays respond to Ambient
Light Override.
Alternate Setting: Classroom Mode Primary
Relay only responds to Ambient Light
Override.
Primary Relay:
Fluorescent: 1200VA @120V, 2700VA @ 277V
Incandescent: 800W @120V
Secondary Relay:
Fluorescent: 800VA @120V, 1200VA 277V
Incandescent: 800W @120V
ODS15-IDW
with 80301-W plate
ODS0D-IDW
with 80301-W plate
COLOR CATALOG NUMBER DESCRIPTION RATING
Ivory ODS15-IDI Fluorescent: 1800VA @ 120V,
White ODS15-IDW Adaptive Infrared 4000VA @ 277V
Gray ODS15-IDG
Occupancy Sensors
Incandescent: 1800W @ 120V
Almond ODS15-IDA Motor:
1
/4 HP @ 120V
COLOR CATALOG NUMBER DESCRIPTION RATING
Ivory ODS0D-IDI
White ODS0D-IDW
Gray ODS0D-IDG
Almond ODS0D-IDA
Commercial Grade Decora

Wall Switch Infrared Occupancy Sensor (Incandescent and Fluorescent)


COLOR CATALOG NUMBER DESCRIPTION RATING
Ivory ODS10-IDI Fluorescent: 1200VA @ 120V,
White ODS10-IDW Infrared 2700VA @ 277V
Gray ODS10-IDG
Occupancy Sensors
Incandescent: 800W @ 120V
Almond ODS10-IDA Motor:
1
/4 HP @ 120V
Commercial Grade Self-Contained Ceiling-Mount Occupancy Sensors
COLOR CATALOG NUMBER DESCRIPTION COVERAGE RATING
White ODC0S-I1W Self-Contained Ceiling-Mount 360, 530 sq. ft. Incandescent: 1000W @ 120V
(formerly 16786-120) Infrared Occupancy Sensor Fluorescent/Inductive:
and Switching Relay 1000VA @ 120V For 60Hz AC only.
1HP@120V AC
White ODC0S-I2W Self-Contained Ceiling-Mount 360, 530 sq. ft. Incandescent: 1000W @ 220V
Infrared Occupancy Sensor Fluorescent/Inductive:
and Switching Relay 500VA @ 220V For 50Hz AC only.
White ODC0S-I7W Self-Contained Ceiling-Mount 360, 530 sq. ft. Fluorescent/Inductive:
(formerly 16786-277) Infrared Occupancy Sensor 2700VA @ 277V For 60Hz AC only.
and Switching Relay
White ODCCG-000 Protective Cage
ODC0S-I1W
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
For the complete line of Occupancy Sensor Products
request the Occupancy Sensors Product Guide (G-7164).
For the complete line of Lighting Controls products,
request the Lighting Controls Product Catalog (G-6960).
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 21
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
Occupancy Sensors
Commercial Grade Multi-Tech and Ultrasonic
20
C
o
m
m
e
r
c
i
a
l

G
r
a
d
e

C
e
i
l
i
n
g
-
M
o
u
n
t

O
c
c
u
p
a
n
c
y

S
e
n
s
o
r
s
ODC20-M0W
Multi-Technology Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)
Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digital
self-adjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).
Commercial Grade Ceiling-Mount Occupancy Sensors
COLOR CATALOG NUMBER DESCRIPTION COVERAGE OPERATING FREQUENCY
White ODC05-M0W Multi-Tech Ceiling-Mount 180, 500 sq. ft. 40kHz
Occupancy Sensor
Multi-Tech Ceiling-Mount
White ODC05-MRW Occupancy Sensor with Ambient 180, 500 sq. ft. 40kHz
Light Override & Secondary Relay
White ODC10-M0W Multi-Tech Ceiling-Mount 180, 1000 sq. ft. 32kHz
Occupancy Sensor
Multi-Tech Ceiling-Mount
White ODC10-MRW Occupancy Sensor with Ambient 180, 1000 sq. ft. 32kHz
Light Override & Secondary Relay
White ODC20-M0W Multi-Tech Ceiling-Mount 360, 2000 sq. ft. 32kHz
Occupancy Sensor
Multi-Tech Ceiling-Mount
White ODC20-MRW Occupancy Sensor with Ambient 360, 2000 sq. ft. 32kHz
Light Override & Secondary Relay
White ODCRA-000 Hard-Ceiling Raceway Adapter Kit
White ODCCG-000 Protective Cage for Ceiling-Mount
Occupancy Sensors
Ultrasonic Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)
Advanced Ultrasonic sensing technology for highly accurate monitoring with excellent immunity to air currents and other interference. All-digital
self-adjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).
Commercial Grade Ultrasonic Ceiling-Mount Occupancy Sensors
COLOR CATALOG NUMBER DESCRIPTION COVERAGE OPERATING FREQUENCY
White ODC05-U0W Ultrasonic Ceiling-Mount 180, 500 sq. ft. 40kHz
Occupancy Sensor
White ODC05-URW Ultrasonic Ceiling-Mount 180, 500 sq. ft. 40kHz
Occupancy Sensor with Ambient
Light Override & Secondary Relay
White ODC10-U0W Ultrasonic Ceiling-Mount 180, 1000 sq. ft. 32kHz
Occupancy Sensor
White ODC10-URW Ultrasonic Ceiling-Mount 180, 1000 sq. ft. 32kHz
Occupancy Sensor with Ambient
Light Override & Secondary Relay
White ODC20-U0W Ultrasonic Ceiling-Mount 360, 2000 sq. ft. 32kHz
Occupancy Sensor
White ODC20-URW Ultrasonic Ceiling-Mount 360, 2000 sq. ft. 32kHz
Occupancy Sensor with Ambient
Light Override & Secondary Relay
White ODCRA-000 Hard-Ceiling Raceway Adapter Kit
White ODCCG-000 Protective Cage for Ceiling-Mount
Occupancy Sensors
ODC10-U0W
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 22
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
C
o
m
m
e
r
c
i
a
l

G
r
a
d
e

C
e
i
l
i
n
g
-
M
o
u
n
t

&

W
a
l
l
-
M
o
u
n
t

O
c
c
u
p
a
n
c
y

S
e
n
s
o
r
s
21
Occupancy Sensors
Commercial Grade Ultrasonic, Multi-Tech & Infrared
Infrared Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)
Includes Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital self-
adjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).
Commercial Grade Infrared Ceiling-Mount Occupancy Sensors
COLOR CATALOG NUMBER DESCRIPTION COVERAGE
White ODC04-I0W Infrared Ceiling-Mount 360, 450 sq. ft.
Occupancy Sensor
Infrared Ceiling-Mount
White ODC04-IRW Occupancy Sensor with Ambient 360, 450 sq. ft.
Light Override & Secondary Relay
White ODCRA-000 Hard-Ceiling Raceway Adapter Kit
White ODCCG-000 Protective Cage for Ceiling-Mount
Occupancy Sensors
Multi-Technology Wall-Mount Occupancy Sensor (For use with Leviton Power Pack)
Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digital
self-adjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).
Commercial Grade Multi-Technology Wall-Mount Occupancy Sensor
COLOR CATALOG NUMBER DESCRIPTION COVERAGE OPERATING FREQUENCY
White ODW12-M0W Multi-Tech Wall-Mount 110, 1200 sq. ft. 32kHz
Occupancy Sensor
White ODW12-MRW Multi-Tech Wall-Mount 110, 1200 sq. ft. 32kHz
Occupancy Sensor with Ambient
Light Override & Secondary Relay
Infrared Wide-View and High-Bay Wall Mount Occupancy Sensors (For use with Leviton Power Pack)
Includes Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital self-
adjusting technology provides Install and Forget solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).
Commercial Grade Infrared Wide-View Occupancy Sensors
Commercial Grade Infrared High-Bay Occupancy Sensors
COLOR CATALOG NUMBER DESCRIPTION COVERAGE
White ODWWV-I0W Infrared Wide-View Wall-Mount 110, 2500 sq. ft.
Occupancy Sensor
Infrared Wide-View Wall-Mount
White ODWWV-IRW Occupancy Sensor with Ambient 110, 2500 sq. ft.
Light Override & Secondary Relay
White ODWHB-I0W Infrared High-Bay Wall-Mount 120 ft, 14 ft. wide
Occupancy Sensor @ 30 ft. height
Infrared High-Bay Wall-Mount
White ODWHB-IRW Occupancy Sensor with Ambient
120 ft, 14 ft. wide
Light Override & Secondary Relay
@ 30 ft. height
ODW12-M0W
ODWWV-I0W
ODC04-I0W
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 23
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
5300 Series
Six-Outlet Surge Strips
5300 Series - 15A and 20A 120V AC Plug-In Devices
22
P
o
w
e
r

Q
u
a
l
i
t
y

D
e
v
i
c
e
s

-


S
i
x
-
O
u
t
l
e
t

S
u
r
g
e

S
t
r
i
p
s
10 YEAR LIMITED
DESCRIPTION CATALOG NO. APPLICATION HOUSING COLOR
6-Outlet w/ Switch, w/ 6 Cord 5300-PS Data-Sensitive Operations Thermoplastic Beige
6-Outlet w/ Switch, w/ 6 Cord 5300-GS Data-Sensitive Operations Thermoplastic Gray
6-Outlet w/ Switch, w/ 15 Cord 5300-S15 Data-Sensitive Operations Thermoplastic Beige
6-Outlet w/ Switch, w/ 15 Cord 5300-G15 Data-Sensitive Operations Thermoplastic Gray
6-Outlet w/ Switch, w/ 6 Cord 5300-PST Telephone/ Modem Line Protection Thermoplastic Beige
6-Outlet w/ Switch, w/ 6 Cord 5300-GST Telephone/ Modem Line Protection Thermoplastic Gray
6-Outlet w/ Switch, w/ 6 Cord 5300-PSC CATV Line Surge Protection Thermoplastic Beige
6-Outlet w/ Switch, w/ 6 Cord 5300-GSC CATV Line Surge Protection Thermoplastic Gray
Hospital Grade, Tamper-Resistant 5300-HTS Continues to supply power to load Aluminum Beige
6-Outlet w/o Switch, w/ 6 Cord if protection is lost
Hospital Grade, Tamper-Resistant 5300-H15 Continues to supply power to load Aluminum Beige
6-Outlet w/o Switch, w/ 15 Cord if protection is lost
6-Outlet w/ Switch, w/ 6 Cord 5300-IPS For use in rough environments Aluminum Beige
Hospital Grade, Tamper-Resistant 5300-HT2 Continues to supply power to load Aluminum Beige
6-Outlet w/o Switch, w/ 6 Cord 20 AMP if protection is lost
ENVIRONMENTAL
STANDARDS & CERTIFICATIONS
5300 Series
5300-PSC 5300-HT2
CATALOG NO. JOULES UL 1449 (2
nd
Ed) MAX.SURGE CURRENT NOISE REJECTION LOWVOLTAGE CLAMPING
IMPULSE 6kV/500A (test w/ 8x20us wave) (@100kHz-100MHZ) (UL 497A/B or UL 452)
5300-PS 1620 L-N: 330V L-N: 48KA -20 to -40 dB
5300-GS 1620 L-N: 330V L-N: 48kA -20 to -40 dB
5300-S15 1620 L-N: 330V L-N: 48kA -20 to -40 dB
5300-G15 1620 L-N: 330V L-N: 48kA -20 to -40 dB
5300-PST 1620 L-N: 330V L-N: 48kA -20 to -40 dB 270V
5300-GST 1620 L-N: 330V L-N: 48kA -20 to -40 dB 270V
5300-PSC 1620 L-N: 330V L-N: 48kA -20 to -40 dB
5300-GSC 1620 L-N: 330V L-N: 48kA -20 to -40 dB
5300-HTS 1080 L-N: 400V L-N: 36kA -20 to -40 dB
5300-H15 1080 L-N: 400V L-N: 36kA -20 to -40 dB
5300-IPS 1440 L-N: 330V L-N: 27kA -20 to -40 dB
5300-HT2 1080 L-N: 400V L-N: 36kA -20 to -40 dB
SPECIFICATIONS & FEATURES
5300 SERIES
Clamping prole tightly tracks AC
sine wave.
Six protected outlets with ON/OFF
switch.
Resettable circuit breaker and
internal fusing.
5300-HTS
Tamper-proof, Hospital Grade
receptacles
Leakage current below UL 544
100VA limits
STORAGE TEMPERATURE
-35C to 60C
OPERATING TEMPERATURE
-10C to 60C
ANSI/IEEE Categories A & B
C-62.41 & C-62.45
UL 1449, 1363, 1283
#E146315
CSA
#LR-94773
To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:

www.leviton.com
B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 24
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com
Leviton Manufacturing Co., Inc.
59-25 Little Neck Parkway, Little Neck, NY 11362-2591
Telephone: 1-800-323-8920 FAX: 1-800-832-9538
Tech Line (8:30AM-6:00PM E.S.T. Monday-Friday): 1-800-824-3005
Leviton Manufacturing of Canada, Ltd.
165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9
Telephone: 1-800-469-7890 FAX: 1-800-563-1853
Leviton S.A. de C.V.
General Arista 54-A Col. Argentina, Mexico D.F., C.P. 11270
Telephone: 011-525-386-1131, 011-525-386-2052 FAX: 011-525-386-1797
Visit us on the web at: www.leviton.com
Copyright 2006 Leviton Manufacturing Co., Inc. All rights reserved.
B-1027C/F6-tp
For our complete line of Industrial wiring
device products, request Catalog IPD-2.05.
B-1027C HealthBrochure.qxd 7/11/06 2:02 PM Page 1
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA 94080-6370 General Inquiries: (800) 670-4183 www.stevenengineering.com