Professional Documents
Culture Documents
MAY 2012
PVC INSULATED, UNARMOURED BRIGHT ANNEALED COPPER CONDUCTOR SINGLE CORE (UNSHETAHED) & MULTICORE PVC ROUND
OVERALL SHEATHED INDUSTRIAL CABLES FOR VOLATGE GRADE UPTO 1100 V AS PER IS 694/1990 (Rate Per 100 Meters)
Conductor
Area/
Sq.mm.
Conductor/
Construction
No./ Dia. mm
Current
Carrying
Amps
0.50
16/0.20
04
660
1940
2575
3300
5500
6180
0.75
24/0.20
07
920
2600
3500
4400
7200
8140
1.00
1.50
2.50
4.00
32/0.20
30/0.25
50/0.25
56/0.30
11
14
19
26
1200
1700
2780
4330
3100
4100
6700
10300
4330
5900
9370
14700
5700
7700
12300
19300
9200
12300
19800
31700
10500
14200
23100
36700
Conductor
Area/
Sq.mm.
0.50
0.75
1.00
1.50
2.50
Conductor/
Construction
No./ Dia. mm
16/0.20
24/0.20
32/0.20
30/0.25
50/0.25
Current
Carrying
Amps
04
07
11
14
19
Single
core
10 Core
8750
11600
14900
20300
33200
2 Core
12 Core
10400
13800
17800
24100
39800
3 Core
14 Core
12050
16100
20600
28100
45800
4 Core
16 Core
6 Core
19 Core
13700
18500
23400
31900
53000
16200
21500
27900
37900
61800
7 Core
24 Core
20400
27200
34800
48000
78000
PVC INSULATED, UNARMOURED BRIGHT ANNEALED COPPER CONDUCTOR SINGLE CORE (UNSHETAHED) & MULTICORE PVC ROUND
OVERALL SHEATHED INDUSTRIAL CABLES FOR VOLATGE GRADE UPTO 1100 V AS PER IS 694/1990 (Rate Per Meter)
Conductor
Area/ Sq.mm.
Conductor/
Construction
No./ Dia. mm
6
10
16
25
35
50
70
95
120
150
185
240
300
400
84/0.3
80/0.4
126/0.4
196/0.4
276/0.4
396/0.4
354/0.5
484/0.5
608/0.5
750/0.5
925/0.5
1210/0.5
1527/0.5
2036/0.5
Current
Carrying
Amps
37
51
68
86
110
145
215
260
305
355
415
500
585
695
Single core
63.90
111.00
174.00
276.00
386.00
556.00
787.00
1050.00
1350.00
1680.00
2044.00
2697.00
3430.00
4592.00
2 Core
3 Core
4 Core
149.00
214.00
285.00
264.00
379.00
499.00
388.00
585.00
769.00
-949.00
1249.00
-1309.00
1736.00
-1879.00
2514.00
------Current Carrying Capacity :
At Normal Conditions for installation. Before
installation, please refer derating factor.
The diameter of the conductor shown
above is nominal. The size of conductor is
determined by its resistance.
CONDUCTOR
AREA
(SQ.MM.)
CURRENT
CARRYING
AMPS
FIRE
RETARDANT
1.00
12
1070
1130
1.50
16
1600
1690
2.50
22
2580
2730
CONDUCTOR
AREA (SQ.MM.)
Conductor /
construction
(No. / Dia.mm.)
1.5
22/0.3
6180
2.5
36/0.3
9680
56/0.3
14000
84/0.3
21300
4.00
29
3800
4030
10
80/0.4
35000
6.00
37
5640
5980
16
126/0.4
54800
25
196/0.4
10.00
45
9920
10520
35
276/0.4
on enquriy
on enquriy
16.00
68
15900
16850
50
396/0.4
on enquriy
70
354/0.5
on enquriy
RATE
(Per 100 meter)
AS PER IS : 9968
RATE
(Per meter)
16.00
120
203.00
25.00
160
315.00
35.00
230
439.00
50.00
400
627.00
70.00
600
868.00
95.00
700
1156.00