You are on page 1of 5

Customer

Phone
Contact
E-mail
Company Date
Item no.
Project
Project ID
Issued by
Phone
E-mail
08-July -2014
Technical Data
See the table of "Dimensions".
Pump name
1 Fluid
PH v alue
Liquid temperature
Density
Vapour pressure
Kin. v iscosity
Weight %
Static head
Inlet pressure
Altitude
Av ailable sy stem NPSH
2
3
6
4
5
7
8
9
K
kg/m
mm/s
Requested data
US g.p.m.
f t
kPa
kPa
Manuf acturer
Pump ty pe
Design
Impeller Dia. Max.
Designed
Min.
Self -Priming
Speed
Max Working Pressure
Operating
Max-
Min-
Flow
No. of Stage
Operating
- (Qmax.)
- (Qmin.)
Head Shut-of f head
Pump
Shaf t power
Max. Shaf t Power at max. impeller
Ef f iciency
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Horizontal Split Casing
1
16K
397
377
327
1190
0
146.7
109.0
178.7
769
28.09
42.77
75.5
1/min
kPa
mm
mm
mm
US g.p.m.
US g.p.m.
US g.p.m.
f t
f t
f t kW
kW
%
533.41 kPa
PTEI
26
27
28
29
30
31
32
Materials
34
33
35
Casing
Impeller
Shaf t
Shaf t sleev e
Mechanical seal
Ball bearing
Cast iron
Bronze
316 Stainless steel
.
.
.
Remarks
f t
150x100 CNJA 5 30
Water, clean
767
0 0
0
Solids
293
1000
2.2
0
7
3281
1
Frequency 50
Horizontal Split Casing
Yes
16K
Motor
Manuf acturer TECO
Specif ic design TEFC / 50 Hz / Pole pairs 2
1470 1/min
Rated power kW 30
Speed
Electric v oltage V 400
Electric current A 54
3~
IP 55 Degree of protection
200LC_B3_30_3_400
Frame size 200 LC
Flow
Number of pumps
Head 146 f t
Connection JIS
JIS
150x100 CNJA 5 30
Number of poles
Ty pe
Weight; motor
Pump name
Env ironmental temperature
Total weight lb
Hz
Insulation class F
612.87 lb
4
Phases
290 K
1450
1 / 0 Reserv e /
Suction side
Connection Discharge side
1600
m
Required NPSH
Performance curve
Customer
Phone
Contact
E-mail
Company Date
Item no.
Project
Project ID
Issued by
Phone
E-mail
08-July -2014
769
Pump name
1
Static head
2
3
Requested data
US g.p.m.
f t
Impeller Dia. Designed
Speed
Operating Flow
Pump
377
1/min
mm US g.p.m.
150x100 CNJA 5 30
767
0
Frequency 50
1450
Flow
Head 146 f t Hz
Head
Shaft power P2
Efficiency
377
76.6%
147 ft
28.1 kW
75.5 %
769 US g.p.m.
377 (P2)
147 ft
28.1 kW
75.5 %
769 US g.p.m.
377
147 ft
28.1 kW
75.5 %
769 US g.p.m.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
[ft]
0
10
20
[kW]
0
10
20
30
40
50
60
70
[%]
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 [US g.p.m.]
1
Operating Head f t 146.7
Test standard: ISO 9906-Annex A
Water, clean [100%] ; 293K; 998.3kg/m; 1mm/s
Dimensions
Customer
Phone
Contact
E-mail
Company Date
Item no.
Project
Project ID
Issued by
Phone
E-mail
08-July -2014
Pump name 150x100 CNJA 5 30
A 271 Fb M16
B 395 G 269
BC 506 H 190
BJ 235 I 240
BL 1230 L 1440
BM 800 MA 374.5
BN 215 MR 395.5
BW 450 n 4
BY 400 t 4
Dd 100 Weight kg 706
Ds 150
E 380
F 290
A 271 Fb M16
B 395 G 269
BC 506 H 190
BJ 235 I 240
BL 1230 L 1440
BM 800 MA 374.5
BN 215 MR 395.5
BW 450 n 4
BY 400 t 4
Dd 100 Weight kg 706
Ds 150
E 380
F 290
A 271 Fb M16
B 395 G 269
BC 506 H 190
BJ 235 I 240
BL 1230 L 1440
BM 800 MA 374.5
BN 215 MR 395.5
BW 450 n 4
BY 400 t 4
Dd 100 Weight kg 706
Ds 150
E 380
F 290
mm
D 150
e 260
f 305
g 230
h 25
n Num 8
t 28
t1 2
D 100
e 185
f 225
g 160
h 23
n Num 8
t 26
t1 2
mm mm Sucti on si de Pump di mensi ons Di scharge si de
Construction
Customer
Phone
Contact
E-mail
Company Date
Item no.
Project
Project ID
Issued by
Phone
E-mail
08-July -2014
(1/2)
Pump name 150x100 CNJA 5 30
Construction
Customer
Phone
Contact
E-mail
Company Date
Item no.
Project
Project ID
Issued by
Phone
E-mail
08-July -2014
(2/2)
Pump name 150x100 CNJA 5 30

You might also like