You are on page 1of 20

Philips chassis LC7 Software updating page 1

<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
CONSUMER LIFESTYLE
www.ayslearningcentre.philips.com
AtYourService Learning Centre
Consumer Care
Hans Munsters
March 2008
Software updating chassis LC7.xE
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide2
SDM mode:
To Enter: 062596 menu
To Exit: standby
SAM mode:
To Enter: 0 6 2 5 9 6 follow by i+
To Exit: standby
CSM mode:
To Enter: Using RC to key in 1 2 3 6 5 4
To Exit: Press Menu on RC
Display code 062598 menu xxx
Service modes
Philips chassis LC7 Software updating page 2
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide3
Customer Service Mode page 1
Part of SW
12nc display
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide4
Customer Service Mode page 2
HDMI audio
Detected format
1080p board
Ambilight
Philips chassis LC7 Software updating page 3
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide5
SSB top side
7H00 IBO
software
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide6
SSB bottom side
7310 main
software
IBO nvm
HDMI nvm (EDID)
I2C UART
Philips chassis LC7 Software updating page 4
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide7
1080p board for full HD display
1080p software
There is no nvm on
1080p board
Nvm is integrated into
main nvm on SSB
compair
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide8
Software Clustering:
Analogue LCD - LC71EL1_v1.24
Analogue PDP - LC71EP1_v1.24
Digital LCD - LC72EL1_v1.24
Digital PDP - LC72EP1_v1.24
Digital LCD - LC72ELH_v1.15 1080p display
Philips chassis LC7 Software updating page 5
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide9
Software download via excel file
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide10
How to Program LC7 software ?
Behind the tuner there is I2C connection for Compair
Compair I2C
UART
Philips chassis LC7 Software updating page 6
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide11
ComPair & UART Connector
ComPair Interface
ComPair UART Cable
3122 785 90630
IC Adaptor Cable
with small connector
3139 131 03791
ComPair IC cable
3122 785 90004
ComPair II interface
3122 785 91020
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide12
check possibility, if compair
interface is connected. This
is software version of
interface
Philips chassis LC7 Software updating page 7
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide13
Compair installation program available as download, with driver
Driver is with installation program and is
installed on your computer
This is the ComPair version 3 installer.
Engine version 3.1.29.
System requirements:
Windows XP operating system.
USB connection for use with the ComPair II interface (preferably USB2.0).
Min. 256Mb RAM to make Windows XP run smoothly, 512Mb for Windows Vista.
Use ComPair with at least 1024x768 screen resolution on your PC.
Switch off screen savers and power management tools when using any set software
upgrade feature in ComPair.
Known issues:
The Winamp MP3 player program interferes with the LC04 NVM read/write tool.
Starting up ComPair with something connected to the RS232/UART connector of the
interface might cause a hang-up of ComPair.
Install ComPair II interface firmware 0.0.2.6.
You can find the latest ComPair II interface firmware also on this website.
The setup includes the USB driver for the new ComPair II interface. Please refer to the
booklet packed with the USB interface to install the USB driver.
ComPair version 3 is compatible with the old and the new interface, according to the
ComPair settings applied. See the ComPair Feature and order code list (also available on
this website) for details per chassis.
Solved/added in this version:
Support for the LC08 platform added.
Support for the LC07 platform improved.
Support for TPM1.1U and TPM1.2U software upgrade feature.
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide14
Philips chassis LC7 Software updating page 8
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide15
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide16
Select upgrade of the software or upgrade in case of empty flash * (then there is
no feedback that the set is in Compairmode)
If software upgrade is completed (inclusive nvm), then type number, serial
number, SSB, options have to be checked or programmed
Check in CSM
Empty flash (932221272668) does not work
Preprogrammed IC:
313912709911 LC7.2E LB
313912709083 LC7.2E LA
313912701412 LC7.5E
Philips chassis LC7 Software updating page 9
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide17
If the tv is in upgrade mode then also the red LED is on
Shorten I2C connector, in case something went wrong.
TV-set is now also in upgrade mode
Follow the procedure for empty flash
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide18
1. Software upgrade,
2. Nvm
3. Displaycode
4. Typenumber
5. Serialnumber
6. SSB
7. Options
During upgrade black screen
and red LED is blinking
Philips chassis LC7 Software updating page 10
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide19
Upgrade nvm
In CSM version is indicated
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide20
Upgrade nvm
Set is in factory mode V-/P- local keyboard
Check displaycode
Disconnect all cables after upgrade!!
Little load to I2C bus gives strange problems
Philips chassis LC7 Software updating page 11
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide21
Model number programming
Add spaces to get 15 characters
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide22
Read production code, to
check what is programmed
Philips chassis LC7 Software updating page 12
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide23
Also 12nc SSB has to be programmed.
Read SSB 12 nc to check what is programmed
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide24
Via tools nvm edit
In case specific address has
to be editted
Philips chassis LC7 Software updating page 13
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide25
EDID nvm programming
For writing:
make sure the EEPROM in the set is NOT write protected (for the 24Cxx, pin 7 must be at 0V).
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide26
SSB board swop for home repair
DRAFT
Philips chassis LC7 Software updating page 14
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide27
From the video processor various test
pictures can be generated
Also from 1080p board
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide28
Service Alignment Mode
Philips chassis LC7 Software updating page 15
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide29
Addresses in nvm where some data is stored:
407 Option 7
(Smart Sound profile)
4
400 Panel Option Code 3
i.e. SV10003 30003 215 - 228 Serial No 2
i.e. 32PFL5522D/12 200 - 212 Product Model 1
Remark TV NVM
Location (Dec)
Descriptions No.
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide30
GSC_66211 display option code list
Address 400 in nvm there can be checked which display is programmed
Philips chassis LC7 Software updating page 16
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide31
Option codes are in service manual
displaycode
options
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide32
Alignments
White drive
For analogue only try 15 (for DVB-T there is no AGC alignment)
Perfect alignment: insert IF and check voltage at pin 1 of the
tuner (analogue only)
Tuner AGC
Philips chassis LC7 Software updating page 17
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide33
ComPair II
2
nd
generation ComPair interface
Connects to PC via USB
Powered via USB
Supports UART (0V+3V3/+5V
and -15V+15V)
Supports I
2
C
Supports Infrared (RC5, RC6),
transmit and receive
HDMI connector for direct I
2
C
access to HDMI EDID EEPROM
Firmware can be upgraded
Will replace ComPair I from
beginning 2007
ComPair interfaces
ComPair I
Original ComPair interface
Connects to PC via UART
Needs separate power supply
Supports UART (0V+5V)
Supports I
2
C
Supports Infrared (RC5, RC6), but
transmit only
Simulates Dealer Service Tool
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide34
ComPair order codes
ComPairII interface: 3122 785 91020
ComPair CD (release 2006-1): 3122 785 60160*
Installation CD with repair manuals upto January 2007.
ComPair I2C cable: 3122 785 90004
ComPair I2C adapter cable: 3139 131 03791
ComPair UART cable: 3122 785 90630
ComPair UART cable for TV520: 3104 311 12742
DB9 to 3.5mm headphone connectors
ComPair I2C cable for LC7.5 9965 100 07325
ComPair UART cable for LC7.5 3138 188 75051
ComPair cable for TPS1.0E 9965 100 09269
* installation program also available as download
This is the last Compair CD (all info is available via internet)
Philips chassis LC7 Software updating page 18
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide35
How to access
When you entered a model number, select
the Model-Chassis relation link and select the
appropriate type number.
Via the ComPair link you can find all files
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide36
ComPair files for 32PFL5522D
installation
Software for
the interface
Cpz - file
Nvm config
Philips chassis LC7 Software updating page 19
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide37
Cpz-file for 32PFL5522D
Compair chassis
fault finding file has
to be downloaded as
cpz-file
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide38
Philips chassis LC7 Software updating page 20
<< software updating chassis LC7.xE >> << software updating chassis LC7.xE >>
S
E
R
V
I
C
E

T
R
A
I
N
I
N
G
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide39
Compatible with old interface
COMM port is
auto detect
Restart ComPair
browser
Then ComPair I is connected
Philips Consumer Lifestyle, Consumer Care March 2008
<LC7.x software updating>, slide40
www.AYSLearningCentre.philips.com www.AYSLearningCentre.philips.com

You might also like