TA series is a range of moulded case current transformers manufactured to IEC 60185, the International Electrotechnical Commission Standard. The TA series includes CTs only for use with electrical measuring instruments. CTs are designed with aperture dimensions that suit the size of busbar for given primary currents.
TA series is a range of moulded case current transformers manufactured to IEC 60185, the International Electrotechnical Commission Standard. The TA series includes CTs only for use with electrical measuring instruments. CTs are designed with aperture dimensions that suit the size of busbar for given primary currents.
TA series is a range of moulded case current transformers manufactured to IEC 60185, the International Electrotechnical Commission Standard. The TA series includes CTs only for use with electrical measuring instruments. CTs are designed with aperture dimensions that suit the size of busbar for given primary currents.
2 TA Series Moulded Case Current Transformers Introduction The TA Series is a range of moulded case current transformers manufactured to IEC 60185, the International Electrotechnical Commission Standard which specifies the rating and performance requirements for CTs to be used with electrical measuring instruments and protective devices. The TA Series includes CTs only for use with electrical measuring instruments. Product Features Class 3, 1 or 0.5 with 5A and 1A secondaries as standard Compact design having apertures designed for standard busbars up to 4000A Choice of bar or foot mounting Terminal cover and all fixings supplied with each CT as standard User Benefits One range of CTs allows a wide variety of CT applications to be achieved from one supplier Conforms with industry standard dimensions for copperwork, eliminates mounting problems and reduces the requirement for special CTs to accommodate the primary circuit Adaptable and easily mounted Full package approach simplifies ordering process 3 Cable burden in VA Copper cross-section Burden (VA/m) of single conductor (mm 2 ) For 5A secondary CT For 1A secondary CT 0.75 0.047 1 0.034 1.5 0.57 0.023 2 0.43 0.017 2.5 0.34 0.014 4 0.22 0.0085 6 0.14 0.0057 10 0.085 0.0034 Applications In addition to the class accuracy, primary and secondary ratings, when selecting a CT the aperture size and VA rating must also be determined. Aperture size The TA series is designed with aperture dimensions that suit the size of busbar for given primary currents. Table 1 shows the copper busbar current ratings for different sizes of busbar according to DIN 43761. Copper busbar ratings Busbar Current (Amps) No. of bars Dimension (mm) 1 2 3 4 20 x 5 320 560 725 20 x 10 500 925 1320 25 x 3 280 470 525 25 x 5 385 660 840 30 x 3 335 545 590 30 x 5 445 760 940 30 x 10 675 1200 1670 40 x 10 850 1470 2000 2580 50 x 5 695 1140 1330 2010 50 x 10 1020 1720 2320 2950 60 x 5 825 1330 1510 2310 60 x 10 1180 1960 2610 3290 80 x 5 1070 1680 1830 2830 80 x 10 1500 2410 3170 3930 100 x 5 1300 2010 2150 3300 100 x 10 1810 2850 3720 4530 VA rating The VA rating of a CT must be greater than, or equal to, the total VA burden of all the devices being fed and the connecting cable. In order to select a CT with an appropriate VA rating, refer to Tables 2 and 3 which show typical device and cable burdens respectively. Table 1 Typical device burden in VA Moving Iron Instruments 0.4 . . . 1.5 Rectified Moving Coil Instruments 0.5 Power Instrument 1.0 . . . 2.5 Maximum Demand Indicators 2.5 . . . 5.0 Digital Indicators 0.5 . . . 1.0 kWh Meters 1.0 . . . 5.0 Recorders 2.0 . . . 5.0 Istat 300 Transducers 0.2 . . . 1.5 Static Relays 1.0 . . . 2.5 Table 2 Table 3 4 CT Selection Tables All CTs supplied with full fixing kit and terminal cover as standard. All CTs available with either 1A or 5A secondary. VA Primary Class current 0.5 1 3 150 2.5 2.5 200 2.5 3.75 250 1.25 2.5 3.75 300 2.5 2.5 3.75 400 2.5 3.75 5 500 3.75 5 5 600 3.75 5 7.5 Type TA30 VA Primary Class current 0.5 1 3 40 1.25 50 1.25 1.25 60 1.25 2.5 75 1.25 2.5 100 2.5 3.75 125 1.25 3.75 5 150 1.25 5 5 200 2.5 5 7.5 Type TA20 VA Primary Class current 0.5 1 3 100 2 5 10 125 5 7.5 10 150 7.5 10 15 200 10 15 25 250 10 20 30 300 10 20 30 400 15 30 45 500 20 30 45 Type TA100B Dimensions Ratings 5.5 45 57.6 66.4 17 8.5 58 15.5 20.5 41 30.4 45 29 5.5 5.5 45 57.6 23 12.6 11.6 58 21 26 41 30.4 45 29 10.6 66.4 31 75 43 50 10.5 10.5 11 21 31 M4 S 1 k S 2 l 40 82 104.5 M5 32 5.5 50 40 P 1 K 23 Wound primary CTs for lower primary currents are also available on request. 5 VA Primary Class current 0.5 1 3 50 1.5 60 1.5 75 1.5 2.5 100 3 5 125 3 5 150 3 5 200 2.5 5 7 250 3.75 5 7.5 300 5 7.5 10 400 5 7.5 10 500 5 10 15 600 7.5 15 20 750 10 15 25 800 10 15 25 1000 15 20 30 Type TA200 VA Primary Class current 0.5 1 3 400 10 15 30 500 10 15 30 600 10 15 30 750 10 15 30 800 10 15 30 1000 10 15 30 1200 10 15 30 1250 10 15 30 1500 10 15 30 1600 10 15 30 2000 10 15 30 Type TA250 VA Primary Class current 0.5 1 3 400 10 15 30 500 10 15 30 600 10 15 30 750 10 15 30 800 10 15 30 1000 15 25 30 1200 20 30 40 1250 20 30 40 1500 30 40 50 1600 30 40 50 2000 40 50 60 Types TA300/TA380 Dimensions Ratings 2 5 . 6 75 43 50 10.5 10.5 1 0 . 6 M4 S 1 k S 2 l 40 82 104.5 M5 32 5.5 50 40 P 1 K 30.5 3 0 . 6 4 0 . 6 1 2 . 6 2 0 . 6 100 61 50 10.5 10.5 M4 S 1 k S 2 l 54 108 130.5 P 1 46 M5 32 5.5 55 44 K 10.5 21 12 50.5 43 132 70 10.5 10.5 M4 S 1 k S 2 l 66 132 154.5 P 1 52 K 11 43 M5 32 5.5 64 44 32 41 61 81 6 VA Primary Class current 0.5 1 3 800 10 15 30 1000 10 15 30 1200 10 15 30 1250 10 15 30 1500 10 15 30 1600 10 15 30 2000 10 15 30 VA Primary Class current 0.5 1 3 1500 10 15 30 1600 10 15 30 2000 10 15 30 2500 10 15 30 3000 10 15 30 4000 10 15 30 VA Primary Class current 0.5 1 3 2000 10 15 30 3000 10 15 30 4000 10 15 30 5000 10 15 30 Type TA400 Type TA500 Dimensions Ratings Type TA600 M4 M5 S 1 k S 2 l P 1 K 187.5 165 82.5 103 95 43 32 40 59 23 M4 M5 S 1 k S 2 l P 1 K 202.5 180 90 103 115 43 32 44 63 32 124 32 60 32 78 193 38 128 27 55 72 44 32 62 7 Technical Details Manufactured to IEC 60185: current transformers Maximum system voltage: 660V Secondary: 5A or 1A Voltage isolation: 3kV rms for 60 seconds Overload: 1.2 I n continuously Thermal current (I th ): 60 x primary current for one second Dynamic current (I dyn ): 2.5 x I th Rated current factor: 5 x primary Cases: in high impact polycarbonate Linearity The error limits are maintained between the following load values: For CT with VA > 2.5 between 25 and 100% In For CT with VA 2.5 between 50 and 100% In Accuracy at other load values is indicated in Table 4 below: % Accuracy at Phase angle in minutes at CLASS 0.1I n 0.2I n 1I n 1.2I n 0.1I n 0.2I n 1I n 1.2I n 0.5 1 0.75 0.5 0.5 60 45 30 30 1.0 2 1.5 1 1 120 90 60 60 Table 4 How to Order a CT We require the following information: 1. Model type: to suit busbar size 2. CT ratio 3. Class/VA: to suit the loading conditions eg. TA250 800/5A Class 0.5, 10VA To ensure that you order the correct CT, refer to the tables on pages 4, 5 and 6 giving VA ratings for each class available. Dimensions are also given to ensure that the CT is suitable for the busbar. St Leonards Works, Stafford, ST17 4LX England Tel: 44 (0) 1785 223251 Fax: 44 (0) 1785 212232 Email: enquiries@pcs.alstom.co.uk Internet: www.gecalsthomgpc.co.uk 1998 ALSTOM T&D Protection & Control Ltd Our policy is one of continuous development. Accordingly the design of our products may change at any time. Whilst every effort is made to produce up to date literature, this brochure should only be regarded as a guide and is intended for information purposes only. Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. ALSTOM T&D Protection & Control Ltd cannot be held responsible for any reliance on any decisions taken on its contents without specific advice. Publication I7-015E 109810 CPS Printed in England. ALSTOM T&D Protection & Control Ltd