Professional Documents
Culture Documents
Expansion and
Pump Tanks
IAPMO Approved
2013
RPTBR0613
40
50
66
82
100
ETC-2X
ETC-2X
ETC-2X
ETC-2X
ETC-5X
ETC-2X
ETC-2X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
ETC-5X
*Highest recorded inlet water pressure in a 24-hour period of regulated water pressure.
3/ 4 NPTM Connection
Drawn-Steel tank
Butyl Rubber
Parabolic
Diaphragm
30
ETC-2X
ETC-2X
ETC-2X
ETC-2X
ETC-2X
2-Coat Bonded
Polymer Lining
Model Number
ETC-2X
ETC-5X
ETC-10X
Dimensions
in Inches
Gallon
Capacity
40 PSI
60 PSI
Shipping
Weight
(Lbs.)
1.96
4.55
9.21
1.27
3.05
6.55
1.03
2.19
5.25
8 4
11
1538
10316
1434
1534
5
9
20
It ensures that your pump will run for at least one minute
each time it cycles, as required by pump manufacturers.
A properly sized pump and pump tank will work as a team to meet
your needs and will deliver many years of dependable service.
4.25
Pipe Wrench
Pliers
Teflon Tape
7.25
2. If you do not know your pump size or the size of your current
tank, count all your water fixtures. Be sure to include sinks, tubs,
showerheads, outside faucets, utility sinks, dishwasher, washing
machine, etc. Count each fixture individually. Use columns 1 and
3 in the size chart to make your tank selection.
3. If replacing a glass-lined or other standard tank with a
diaphragm tank, use columns 2 and 4 in the size chart to
make your tank selection.
SiziNG chart
MoDEL
VoLuME
(uS gAL)
Hacksaw
DRAWDoWN
30-50 PSi
CoNN SizE
NPT
iNCHES
A
iNCHES
B
iNCHES
C
iNCHES
SHiPPiNg
WEigHT
LBS
PMD-14
14
4.3
1F
24 3/4
2 1/4
15 3/8
26
PMD-20
20
6.1
1F
32 3/4
2 1/4
15 3/8
30
PMD-32
32
9.9
1F
45 1/2
2 1/4
15 3/8
40
PMD-36
36
11.2
1F
32 3/8
2 1/4
20
45
PMD-52
52
16.1
1 1/4 F
38 5/8
2 1/4
23 3/8
77
PMD-65
65
20
1 1/4 F
46 5/8
2 1/4
23 3/8
87
PMD-86
86
26.7
1 1/4 F
59
2 1/4
23 3/8
105
PMD-119
119
37.0
1 1/4 F
61 1/4
2 1/2
26
161
PMDI-2
.6
3/4 M
10 3/16
8 1/4
Number of
eStimated
diaphraGm
StaNdard
water fixtureS
pump Size
taNk modelS
taNk SizeS
PMDI-5
4.5
1.4
3/4 M
14 3/4
11
UP TO 7
5-7 GPM*
PMDH-20
42 GALLON
PMDI-7
2.3
3/4 M
21 1/16
11
14
8-10
10 GPM*
PMD-32 or 36
82 GALLON
PMDI-14
14
4.3
1M
24 9/16
15 3/8
24
12-15 GPM*
PMD-52
82 GALLON
PMD-65
120 GALLON
17-28
20 GPM*
PMD-86, PMD-119
220 GALLON
2. FILL CYCLE
Water is pumped into the reservoir, which forces the diaphragm
upward into the air chamber.
FREE STANDiNg
16-20 GPM*
1. START-UP CYCLE
Diaphragm is pressed against the bottom of the chamber.
10-13
13-16
HoRizoNTAL
Certified to
NSF/ANSI 61-G & 372
3. HOLD CYCLE
Pump-cutoff pressure is attained. Diaphragm reaches its
upmost position. Reservoir is now filled to its rated capacity.
Be sure to plug the air port on a jet pump, since outside air is
no longer needed.
7.3
2.3
3/4 M
12 7/8
21 1/8
11
16
PMDH-14
14
4.3
1M
17 3/8
21 3/4
15 3/8
25 1/2
PMDH-20
20
6.1
1M
17 3/8
27 1/8
15 3/8
30
4. DELIVERY CYCLE
Pump remains shut off while air pressure in top chamber forces
diaphragm downward, delivering water to the system.
1
2
28psi
3
40psi
40psi
4
50psi
50psi
40psi
40psi