You are on page 1of 2

Revised 09/01/96 M2513S

Vane Type Single Pumps


45VSH**A****10(L)
Service Data
61321 BOLT (4 REQD)
OIL & TORQUE 275285 lb.ft.
427333 COVER
289476 SCREW (2 REQD)

995031 INLET SUPPORT PLATE S/A

995018 ROTOR
924081 VANE KIT(INCLUDES
12 VANES & INSERTS)
RING (SEE TABLE)
995032 OUTLET
SUPPORT PLATE
586594 ORING
419675 SEALING RING
586588 ORING
588509 BACKUP RING
158630 LOCK RING
102949 RETAINING RING
131812 BEARING
995010 SHAFT - #412 KEYED
239751 KEY
194878 WASHER
394974 SHAFT SEAL

924018 BODY S/A
205533 SCREW
(2 REQD)
205077 FOOT
BRACKET
(OPTIONAL)
MODEL
(USGPM)
RING CARTRIDGE KIT
280031 PIN
(2 REQD)
INCLUDED IN CARTRIDGE KIT
INCLUDED IN SEAL KIT 919850
INCLUDED IN FOOT BRACKET KIT FBC10
ASSEMBLE SEAL WITH SPRING LOADED SEALING
MEMBER TOWARDS BEARING. SEALS TO BE
COMPLETELY WETTED WITH OIL PRIOR TO ASSEMBLY.
INSTALL 419675 SEALING RING INTO BODY,
THEN INSTALL CARTRIDGE KIT.
*
*
(370 380 N.m)
42
50
60
581679
581680
578904
995013
995014
995015
427335 PIN (2 REQD)
Vickers

Vane Pumps
90 SAE Port Connections
MODEL CODE BREAKDOWN
3 4 5 6 7 8 2 1
Series
US GPM Capacity
SAE RATING 1200 RPM100 PSI (
42, 50, 60
Code Inlet Outlet
4BOLT FLG. 4BOLT FLG.
Mounting
1
2
3
4
5
6
7
8
Opposite Inlet
CCW from Inlet
_ CW from Inlet
Shaft Type
Outlet Positions
(Viewed from cover end of pump)
A Outlet
B Outlet 90_
C Outlet Inline with Inlet
D Outlet
Design
Shaft Rotation
(Viewed from shaft end)
L Left Hand (CCW Rotation)
Omit Right Hand (CW Rotation)
)
A
412 Str. Key
F Foot
Omit Flange
(IntraVane Type Pump)
45VSH 42 A F * A 10 L
45VSH
10
SAE RATING 1200 RPM7 bar ( )
To reverse cartridge kit rotation, remove the two screws and re-
verse the location of the inlet support plate and outlet support
plate. Reinstall the two screws hand tight. Use pump cover to
align all sections of the cartridge. Carefully remove the cover
and tighten the screws.
Sharp Edges of Vane Must Lead in Direction of Rotation
NOTE
LH RH
LH RH
LH RH
LH RH
For satisfactory service life of these components, use full flow filtration to provide fluid which meets ISO cleanliness code 18/15 or
cleaner. Selections from Eaton OFP,OFR and OFRS filter series are recommended.
When ordering spare cartridge parts, it is recommended they
be obtained in cartridge kits. Kits are assembled and tested by
Vickers for either right or left hand rotation. If left hand rotation is
required, it should be specified on parts order by adding suffix
L to cartridge kit number.
Cover End Cartridge
R. H. Rotation
Shaft End Cartridge
R. H. Rotation
NOTE
Standard right hand shaft rotation cartridges shown.
Reverse for left hand rotation.
Eaton Hydraulics, Incorporated 2000
All Rights Reserved Printed in U.S.A.

You might also like