: TS08100035-EME
Page 1 of 42
LABORATORY MEASUREMENTS
Pursuant To
47 CFR FCC Part 15 Subpart B (2008)
And
FCC Procedure ANSI C63.4 (2003)
Report Engineer
0597
Julie Wang
Reviewed By
Project Engineer
Table of Contents
1. General Information
The EUT is a Digital Wireless Video Baby Monitor, and was defined as information
technology equipment.
2. Test Summary
Emission
Standard Test Type Result Remarks
FCC Subpart B Pass by -7.28 dB at 0.360 MHz at
Conducted Emission Test PASS
Section 15.107 Class B Line Phase
Remark:
The EUT has been tested/evaluated and pass the FCC Part 15 Subpart B without
modification.
Report No.: TS08100035-EME
Page 5 of 42
3. Test Specifications
3.1 Standards
The following standards were applied for testing:FCC standard: 47 CFR FCC Part 15,
Subpart B. Clause 15.107 and 15.109.
The EUT setup configuration please refer to the photo of test configuration in item.
Unintentional radiator:
A device which is not intended to emit RF energy by radiation or induction.
Note:
A manufacturer may also qualify a device intended to be marketed in a commercial,
business or industrial environment as a Class B digital device, and in fact is
encouranged to do so, provided the device complies with the technical specifications for
a Class B Digital Device. In the event that a particular type of device has been found
to repeatedly cause harmful interference to radio communications, the Commission may
classify such a digital device as a Class B Digital Device, regardless of its intended use.
The EUT was supplied with DC 6V from adapter (120 Vac, 60 Hz) and was tested in
normal operating mode.
Report No.: TS08100035-EME
Page 6 of 42
(1) TTD-41T
wireless
AC Power
LISN 1 TTD-41T
wireless
LISN 2 TTD-61R
EMI
Receiver
AC Power
AC Power
LISN 1 TTD-61R
wireless
LISN 2 TTD-41T
EMI
Receiver
AC Power
The EUT along with its peripherals were placed on a 1.0 meter(W)×1.5 meter(L)
and 0.8 meter in height wooden table and the EUT was adjusted to maintain a
0.4meter space from a vertical reference plane. The EUT was connected to power
mains through a line impedance stabilization network (LISN), which provided 50
ohm coupling impedance for measuring instrument and the chassis ground was bounded
to the horizontal ground plane of shielded room. The excess power cable between the
EUT and the LISN was bundled.
All connecting cables of EUT and peripherals were moved to find the maximum
emission
Report No.: TS08100035-EME
Page 7 of 42
0.50~5.00 73 60 56 46
5.00~30.0 73 60 60 50
Phase: Line
Model No.: TTD-41T
Test Condition: Normal operating mode
Remark:
1. Corr. Factor (dB)= LISN Factor (dB) + Cable Loss (dB)
2. Margin (dB) = Level (dBuV) – Limit (dBuV)
Report No.: TS08100035-EME
Page 9 of 42
Phase: Neutral
Model No.: TTD-41T
Test Condition: Normal operating mode
Remark:
1. Corr. Factor (dB)= LISN Factor (dB) + Cable Loss (dB)
2. Margin (dB) = Level (dBuV) – Limit (dBuV)
Report No.: TS08100035-EME
Page 10 of 42
Phase: Line
Model No.: TTD-61R
Test Condition: Normal operating mode
Remark:
1. Corr. Factor (dB)= LISN Factor (dB) + Cable Loss (dB)
2. Margin (dB) = Level (dBuV) – Limit (dBuV)
Report No.: TS08100035-EME
Page 11 of 42
Phase: Neutral
Model No.: TTD-61R
Test Condition: Normal operating mode
Remark:
1. Corr. Factor (dB)= LISN Factor (dB) + Cable Loss (dB)
2. Margin (dB) = Level (dBuV) – Limit (dBuV)
Report No.: TS08100035-EME
Page 12 of 42
(1) TTD-41T
The figure below shows the test setup, which is utilized to make these measurements.
1.0~4.0 meters
wireless Receiver
3 meters
Antenna
TTD-41T
0.8m
Ground Plane
□
wireless
RF Test
Receiver
TTD-61R
The equipment under test was placed on the top of rotation table 0.8 meter above
ground plane.
The table was 360 degrees to determine the position of the highest radiation.
EUT is set 3 meters from the EMI receiving antenna, which is mounted on a variable
height mast. The antenna height is varied between one meter and four meters above
ground to find the maximum value of the field strength. Both horizontal polarization
and vertical polarization of the antenna are set to make the measurement. The
bandwidth was setting on the EMI meter 120 kHz.
The levels are quasi peak value readings.
Report No.: TS08100035-EME
Page 13 of 42
(2) TTD-61R
The figure below shows the test setup, which is utilized to make these measurements.
1.0~4.0 meters
wireless Receiver
3 meters
Antenna
TTD-61R
0.8m
Ground Plane
□
wireless
RF Test
Receiver
TTD-41T
The equipment under test was placed on the top of rotation table 0.8 meter above
ground plane.
The table was 360 degrees to determine the position of the highest radiation.
EUT is set 3 meters from the EMI receiving antenna, which is mounted on a variable
height mast. The antenna height is varied between one meter and four meters above
ground to find the maximum value of the field strength. Both horizontal polarization
and vertical polarization of the antenna are set to make the measurement. The
bandwidth was setting on the EMI meter 120 kHz.
The levels are quasi peak value readings.
Report No.: TS08100035-EME
Page 14 of 42
(3) TTD-41T
The figure below shows the test setup, which is utilized to make these measurements.
Antenna
Tower
TTD-41T
0.8 m
Ground Plane
wireless □
RF Test
TTD-61R Receiver
The equipment under test was placed on the top of rotation table 0.8 meter above
ground plane.
The table was 360 degrees to determine the position of the highest radiation.
EUT is set 3 meters from the EMI receiving antenna, which is mounted on a variable
height mast. The antenna height is varied between one meter and four meters above
ground to find the maximum value of the field strength. Both horizontal polarization
and vertical polarization of the antenna are set to make the measurement.
Report No.: TS08100035-EME
Page 15 of 42
(4) TTD-61R
The figure below shows the test setup, which is utilized to make these measurements.
Antenna
Tower
TTD-61R
0.8 m
Ground Plane
wireless □
RF Test
TTD-41T Receiver
The equipment under test was placed on the top of rotation table 0.8 meter above
ground plane.
The table was 360 degrees to determine the position of the highest radiation.
EUT is set 3 meters from the EMI receiving antenna, which is mounted on a variable
height mast. The antenna height is varied between one meter and four meters above
ground to find the maximum value of the field strength. Both horizontal polarization
and vertical polarization of the antenna are set to make the measurement.
Report No.: TS08100035-EME
Page 16 of 42
According to FCC 15.109, except for Class A digital device, the field strength of radiated
emission from unintentional radiators at a distance of 3 meters shall not exceed the
following values:
Polarity: Vertical
Model No.: TTD-41T
Test Condition: Normal operating mode
Frequency range: 30 MHz~1 GHz
Remark:
1. Emission (dBμV)= Factor (dB)+ Reading(dBμV)
2. Margin = Emission (dBμV) – Limit (dBμV)
Report No.: TS08100035-EME
Page 18 of 42
Polarity: Horizontal
Model No.: TTD-41T
Test Condition: Normal operating mode
Frequency range: 30 MHz~1 GHz
Remark:
1. Emission (dBμV)= Factor (dB)+ Reading(dBμV)
2. Margin = Emission (dBμV) – Limit (dBμV)
Report No.: TS08100035-EME
Page 19 of 42
Polarity: Vertical
Model No.: TTD-61R
Test Condition: Normal operating mode
Frequency range: 30 MHz~1 GHz
Remark:
1. Emission (dBμV)= Factor (dB)+ Reading(dBμV)
2. Margin = Emission (dBμV) – Limit (dBμV)
Report No.: TS08100035-EME
Page 20 of 42
Polarity: Horizontal
Model No.: TTD-61R
Test Condition: Normal operating mode
Frequency range: 30 MHz~1 GHz
Remark:
1. Emission (dBμV)= Factor (dB)+ Reading(dBμV)
2. Margin = Emission (dBμV) – Limit (dBμV)
Report No.: TS08100035-EME
Page 21 of 42
Polarity: Vertical
Model No.: TTD-41T
Test Condition: Normal operating mode
Frequency range: 1 GHz~2.0 GHz(Peak)
The Radiated Emission was very low against the limit in the frequency range
1 GHz ~ 2 GHz.
Polarity: Horizontal
Model No.: TTD-41T
Test Condition: Normal operating mode
Frequency range: 1 GHz~2.0 GHz(Peak)
The Radiated Emission was very low against the limit in the frequency range
1 GHz ~ 2 GHz.
Report No.: TS08100035-EME
Page 22 of 42
Polarity: Vertical
Model No.: TTD-61R
Test Condition: Normal operating mode
Frequency range: 1 GHz~2.0 GHz(Peak)
The Radiated Emission was very low against the limit in the frequency range
1 GHz ~ 2 GHz.
Polarity: Horizontal
Model No.: TTD-61R
Test Condition: Normal operating mode
Frequency range: 1 GHz~2 GHz(Peak)
The Radiated Emission was very low against the limit in the frequency range
1 GHz ~ 2 GHz.
Report No.: TS08100035-EME
Page 23 of 42
TTD-41T
TTD-41T
Report No.: TS08100035-EME
Page 38 of 42
TTD-61R
TTD-61R
Report No.: TS08100035-EME
Page 39 of 42
TTD-41T
TTD-41T
Report No.: TS08100035-EME
Page 40 of 42
TTD-41T
TTD-41T
Report No.: TS08100035-EME
Page 41 of 42
TTD-61R
TTD-61R
Report No.: TS08100035-EME
Page 42 of 42
TTD-61R
TTD-61R