You are on page 1of 125

Daikin UK Price List 2013

Integrated solutions
your comfort. our world.
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
V
R
V

V
e
n
t
i
l
a
t
i
o
n
C
o
m
m
e
r
c
i
a
l

H
e
a
t
i
n
g
R
e
f
r
i
g
e
r
a
t
i
o
n
A
p
p
l
i
e
d
M
i
s
c
e
l
l
a
n
e
o
u
s
London head ofce
Daikin UK
The Heights, Brooklands, Weybridge
Surrey KT13 0NY
Telephone 0845 641 9300
Bristol ofce
Daikin UK
Maple House, Brotherswood Court
Great Park Road, Almondsbury
Bristol BS32 4QW
Telephone 0845 641 9320
Birmingham ofce
Daikin UK
Unit 8, Holly Park, Spitfre Road
Birmingham, West Midlands B24 9PB
Telephone 0845 641 9370
Manchester ofce
Daikin UK
17b Cobra Court, Blackmore Road
Manchester M32 0QY
Telephone 0845 641 9340
Glasgow ofce
Daikin UK
Unit 2, Glasgow Airport Business Park
Marchburn Drive, Paisley PA3 2SJ
Telephone 0845 641 9330
As a wholly owned subsidiary of Daikin Europe
NV, Daikin UK is a leading supplier of heating
and cooling solutions for residential, commercial
and industrial applications. Our product portfolio
comprises a wide range of highly energy ecient
climate control systems which provides the right
solution for any application and requirement.
Daikin UK is a nationwide organisation with its headquarters in
Weybridge, Surrey. Strategically situated regional sales oces
achieve ecient response combined with administration,
distribution and eld quality service departments.
Daikin UK
Conditions
Capacity conditions
Unit cooling and heating capacities shown within this price list
are based on the following conditions:
Nominal cooling
Ambient = 35C
Internal = 27C db 19C wb
Nominal heating
Ambient = 7C db 6C wb
Internal = 20C db
UK cooling
Ambient = 30C
Internal = 22C db 16C wb
Seasonal efciency
Systems of up to 12kW must now show Seasonal Eciency
Ratings instead of Nominal Eciency Ratings. These ratings
(SEER for cooling, SCOP for heating) represent how eective
a system is throughout the year, and are in accordance with
EN14825. For more information on Seasonal Eciency,
visit www.daikin.co.uk/seasonal-eciency
For Daikin UK, this means all our Split and Sky Air products
up to 12kW display SEER and SCOP data along with Energy Label
information and Annual Energy Consumption of the system.
The AEC is based upon 500 hours use per year.
Nominal efciency
This measure of eciency is calculated by dividing the capacity
output of a unit by the power required to deliver it. For cooling,
this is expressed as EER, for heating as COP.
Nominal eciencies are used for systems above 12kW. It is not
possible to compare nominal and Seasonal Eciency ratings.
Cooling mode
Unless otherwise indicated, all units within this price list are
air-cooled.
UK. prefx accessories
All accessory items shown in this price list with the prex UK.
are not manufactured by Daikin.
1
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Price List 2013
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
V
R
V

V
e
n
t
i
l
a
t
i
o
n
C
o
m
m
e
r
c
i
a
l

H
e
a
t
i
n
g
R
e
f
r
i
g
e
r
a
t
i
o
n
A
p
p
l
i
e
d
M
i
s
c
e
l
l
a
n
e
o
u
s
Discount Rating
Please insert your discounts here and then refer to the colour tabs on the edge of each page for reference.
Applied
MY DISCOUNT
%
Ventilation
MY DISCOUNT
%
Refrigeration
MY DISCOUNT
%
VRV
MY DISCOUNT
%
Commercial Heating
MY DISCOUNT
%
Split, Sky Air Heat Pumps
MY DISCOUNT
%
Contents
New for 2013 02
Split, Sky Air Heat Pumps 04
VRV 43
Ventilation 87
Commercial Heating 89
Refrigeration 93
Applied 97
Miscellaneous 111
Integrated Solutions 2
Page 19 - 21 / 46
Page 45
Page 22 - 23 / 44
Page 58 - 61
VRVIV HEAT PUMP RYYQ-T
Variable refrigerant temperature
Customise your VRV for best seasonal eciency
Continuous comfort
The new standard in heating comfort
VRV congurator
Software for simplied commissioning, conguration
and customisation
FULLY FLAT CASSETTE FFQ-C / FXZQ-A
Unique design in the market: integrates fully at into the ceiling and ts ush into
architectural ceiling modules
Remarkable blend of iconic design and engineering excellence with an elegant
nish in matt crystal white or a combination of silver and matt crystal white
Even more energy ecient with the presence sensor (optional)
Oering improved comfort with the oor sensor (optional)
Individual ap control: one ap can be easily closed via the wired remote
controller (BRC1E52A) when refurbishing or rearranging your interior
No optional adapter needed for DIII-connection of Sky Air model
2-WAY BLOW CEILING MOUNTED CASSETTE FXCQ-A
Low energy consumption thanks to specially developed small tube heat
exchanger, DC inverter fans and drain pumps
Stylish unit blends easily with any interior, as the aps close entirely
when not in operation
Improved comfort with automatic air ow adjustment to required load
Individual ap control: one ap can be easily closed via the wired remote
controller (BRC1E52A) when refurbishing or rearranging your interior
CEILING SUSPENDED CASSETTE FHQ-C / FXHQ-A
Low energy consumption thanks to DC inverter fans and drain pumps
Stylish unit blends easily with any interior, as the aps close entirely when
not in operation
No optional adapter needed for DIII-connection of Sky Air model
SLIM CONCEALED CEILING UNIT FDXS-F / FXDQ-A
For residential applications
Compatible with Split, Sky Air, VRV III-S
Reduced fan motor consumption
thanks to the DC fan motor
New for 2013
N
E
W
N
E
W
N
E
W
N
E
W
N
E
W
Page 32 / 47
Price List 2013 3
4-WAY BLOW CEILING SUSPENDED UNIT FUQ-C / FXUQ-A
Low energy consumption thanks to specially developed small tube heat
exchanger, DC inverter fans and drain pumps
Stylish unit blends easily with any interior, as the aps close entirely when not
in operation
Improved comfort with automatic air ow adjustment to required load
Same outlook for all models (unied dimensions)
No optional adapter needed for DIII-connection of Sky Air model
Separate BEVQ box is no longer needed for VRV model: the expansion valve is
integrated in the indoor unit
INTELLIGENT TOUCH MANAGER DCM601A51
Intuitive user interface
Smart energy management
Flexible in size (from 64 to 2,560 groups)
Flexible integration (from simple A/C control to small BMS)
Easy servicing and commissioning with remote refrigerant
containment check
DAIKIN SERVICE APP
To help installation and service engineers, Daikin UK has developed a new
service tool, which provides fast access to information when working with
Daikin VRV products
Flexible integration (from simple A/C control to small BMS)
Easy servicing and commissioning with remote refrigerant containment check
The Daikin service application is for iphone and ipads
Available at the Apple App Store
Designed to help eld engineers to set up and service Daikin VRV equipment
DAIKIN CITY
Daikin UK has launched Daikin City 2.0, a major upgrade of its
interactive virtual environment that now features a library and
a broadcast centre
The library already contains over 120 brochures and data
books regularly, as well as specication documents, case
studies, industry guides and operation manuals
WALL MOUNTED UNITS FTXS-K
Extension with 35-, 42- and 50-class
Discrete, modern design
High quality matt crystal white nish
Whisper quiet in operation. Sound pressure level down to 19dBA
Intelligent Eye sensor enhances comfort
and saves energy
Page 10
N
E
W
Page 29 / 46
N
E
W
Page 82
N
E
W
N
E
W
N
E
W
4
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
5
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Split, Sky Air Heat Pumps
Energy Efciency 6
Introduction 7
Pair Applications 8
Wall Mounted Split Systems 8
Floor Standing Split Systems 14
Flexi Type Split Systems 18
Ceiling Mounted Split Systems 19
Cassette Split Systems 22
Ceiling Suspended Cassette Split Systems 29
Ducted Split Systems 30

Multi Applications 34
Multi Split Systems 34
Twin, Triple, Double Twin Systems 36
Integrated Solutions 6
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
The new energy labelling
indicates the energy
eciency of the product
from A+++, A++, A+, A, B
etc and, unlike the old label,
it includes cooling and
heating. It also states the
sound emissions of the unit.
It is not possible to simply
compare new and old
energy classes (i.e. an old
A label is not equivalent
to a new A label). There is
no direct relation between
SEER and EER. The energy
label will be provided in the
box with the outdoor unit
and on the Energy Label
Generator.
www.daikineurope.com/
energylabel
How the new energy label looks
By the year
2020
European
action plan
20/20/20
CO
2
EMISSIONS
vs. 1990
-20%
Share of
RENEWABLE ENERGY
20%
PRIMARY ENERGY USE
vs. Business as usual
-20%
COOLING
Energy label
Design capacity
of the system
(Pdesign = 35c)
SEER rating
Annual energy
consumption
HEATING
Energy label
Design capacity of
the system for the
average climate zone
(Pdesign = -10c)
SCOP rating
Annual energy
consumption
SOUND POWER
Sound level indoor
Sound level outdoor
The European Union 20/20/20 energy policy sets ambitious targets for energy eciency and
environmental impact:
The ErP Directive
The Energy related Products (ErP) Directive species minimum
eciency requirements, which must be integrated into
energy-using products. The ErP Directive is a compulsory
programme which established EcoDesign requirements initially
for residential lighting and consumer electronics but from 2013,
has introduced them for air conditioning systems too.
So far, products of less than 12kW are governed by the ErP
Directive (Lot 10): typically high end residential and light
commercial applications. Products that do not meet minimum
Seasonal Eciency standards cannot carry the CE mark and can
no longer be imported or sold in Europe.
Timescales for Implementation
Low eciency products are banned from the market from
January 2013. The minimum energy eciency threshold will be
redened again in 2014, so even higher eciency levels will be
required to meet the ever stricter energy eciency requirements.
The EU 20/20/20 targets
CO
2
The Sky Air Seasonal Smart outdoor unit oers at least 20% better performance than existing
inverter solutions, which is fully in line with 20/20/20 EU policy. The technology used gives very high
levels of Seasonal Eciency while improving comfort and reducing running costs. Performance can
be further enhanced with smart use of Daikins unique options and settings.
Seasonal Smart can be used in a wide range of applications through features such as:
EDP setting for use in low humidity, continuous cooling applications such as computer and IT rooms
R22/R407 c replacement technology to help deliver major energy savings and rapid payback
Guaranteed operation in heating mode down to -20C external temperature
75m pipe run to allow longer distance between indoor and outdoor units
D-BACS compatibility to link the Sky Air system into a wider building management system
Customisable evaporating and condensing temperatures to improve operating eciencies and reduce draughts
3 phase and single phase power for all capacities
Price List 2013 7
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
The Sky Air Seasonal Classic outdoor unit oers seasonal performance for a range of
applications, allowing a system to comply with the new regulations in a cost-eective way.
Seasonal Classic now has a compact single fan casing for the 6.8kW, 9.5kW and 12.0kW units
making it more suitable to be installed in smaller spaces.
Seasonal Classic also includes:
R22/R407 c replacement technology to help deliver major energy savings and rapid payback
Guaranteed operation in heating mode down to -15C external temperature
50m pipe run between indoor and outdoor units
3 phase and single phase power units are available
New Sky Air online running cost
calculator from Daikin UK
Demonstrate to your customers the savings that
can be achieved with a Sky Air solution using
Daikin UKs new online calculator
This will enable you to:
Calculate running costs for typical applications
Compare them with Daikins unique energy saving options
Download results as a PDF to attach with your quotes
Try our NEW online running cost calculator today.
Visit www.daikin.co.uk/seasonal-efciency
Daikin again leads the industry with their full light commercial
range optimised for seasonal efciency.
Integrated Solutions 8
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Wall Mounted Inverter
Ururu Sarara
Indoor Units FTXR28E FTXR42E FTXR50E
Capacity UK Total Cooling kW 2.74 4.11 4.89
UK Sensible Cooling kW 2.28 2.93 3.34
Nominal Cooling kW 2.80 4.20 5.00
Nominal Heating kW 3.60 5.10 6.00
Seasonal Efciency
(EN14825)
COOLING
Energy Label B A A
Pdesign kW 2.80 4.20 5.00
SEER 4.91 5.46 5.22
Annual Energy Consumption kWh 200 269 335
Seasonal Efciency
(EN14825)
HEATING
Energy Label A++ A+ A+
Pdesign kW 4.00 4.90 5.60
SCOP 5.08 4.50 4.27
Annual Energy Consumption kWh 1,101 1,523 1,834
Nominal Efciency EER / COP 5 / 5.14 4 / 4.32 3.42 / 3.97
Energy Label A / A A / A A / A
Annual Energy Consumption kWh 280 525 730
Air Flow Rate High / Low m
3
/min 11.1 / 6.5 12.4 / 6.8 13.3 / 7.3
Dimensions Height mm 305 305 305
Width mm 890 890 890
Depth mm 209 209 209
Weight kg 14 14 14
Sound Pressure High / Low dBA 39 / 26 42 / 27 44 / 29
Sound Power dBA 55 58 60
Outdoor Units RXR28E RXR42E RXR50E
Dimensions Height x Width x Depth mm 693 x 795 x 285 693 x 795 x 285
Weight kg 48 48 48
Electrical Details Power Supply 1ph
Running Current A 2.84 4.99 6.92
Starting Current A 3.9 5.9 7.4
Max Fuse Size A 16 16 16
Interconnection Wiring Core / Cable size 3+E / 1.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8
Pipework Maximum Length m 10 10 10
Maximum Vertical Rise m 8 8 8
Precharged to m 10 10 10
Additional Charge g/m -
Holding Charge kg 1.4 1.4 1.4
Sound Pressure High dBA 46 48 50
Sound Power dBA 46 48 50
Trade Fan Coil Price 322.00 377.00 495.00
Trade Condensing Unit Price 875.00 1,013.00 1,066.00
Total System Price 1,197.00 1,390.00 1,561.00
Accessory Ref Description Trade Price
KRP413A1S Adaptor PCB for remote on/of control - constant/pulse contact 73.00
KRP928A2S Adaptor PCB for interface to Daikin centralised control systems 129.00
KLIC-DD KNX interface for Split type systems 160.00
RTD-RA Adaptor PCB for Modbus connection and/or extended system functions 156.00
KPMH974A402 2m extension humidifcation hose- Ururu Sarara 46.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories: Notes:
i) All fan coils supplied as standard with
infrared controller
ii) Minimum ambient operating
temperatures:
Cooling Heating
RXR -10C -20C
Features:
Daikin introduce a new concept in wall mounted split systems
The Ururu Sarara product is unique in providing:
Cooling
Heating
Humidifcation
De-Humidifcation
Fresh Air Intake
Air Purifcation
All the operating modes needed to provide exactly the room comfort required, as well as using R410A refrigerant and Inverter technology,
to provide eciency exceeding the requirements for Energy Label A
Advanced Remote Control:
The user friendly remote controller displays the actual room temperature and humidity level
All commonly used buttons are easily accessible, with advanced controls available beneath the hinged cover
Operating mode buttons are colour coded which is repeated on a indicator lamp on the fan coil cover
This panel changes colour to allow instant identication of the current operating mode
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Price List 2013 9
Wall Mounted Inverter
Emura
Indoor Units Matt Crystal White Brushed Aluminium
FTXG25JW FTXG35JW FTXG50JW FTXG25JA FTXG35JA FTXG50JA
Capacity UK Total Cooling kW 2.44 3.42 4.46 2.44 3.42 4.46
UK Sensible Cooling kW 1.91 2.44 2.93 1.91 2.44 2.93
Nominal Cooling kW 2.50 3.50 5.00 2.50 3.50 5.00
Nominal Heating kW 3.40 4.00 5.80 3.40 4.00 5.80
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A++ A A++ A++ A
Pdesign kW 2.50 3.50 5.00 2.50 3.50 5.00
SEER 6.53 6.51 5.45 6.53 6.51 5.45
Annual Energy Consumption kWh 134 188 321 134 188 321
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A+ A A+ A+ A
Pdesign kW 2.80 3.30 4.60 2.80 3.30 4.60
SCOP 4.34 4.23 3.87 4.34 4.23 3.87
Annual Energy Consumption kWh 903 1091 1660 903 1091 1660
Nominal Efciency EER / COP 4.46 / 4.36 3.93 / 4.04 3.21 / 3.63 4.46 / 4.36 3.93 / 4.04 3.21 / 3.63
Energy Label A / A A / A A / A A / A A / A A / A
Annual Energy Consumption kWh 280 445 780 280 445 780
Air Flow Rate High / Low m
3
/min 8.8 / 4.7 10.1 / 4.6 10.5 / 6.9 8.8 / 4.7 10.1 / 4.6 10.5 / 6.9
Dimensions Height mm 295 295 295 295 295 295
Width mm 915 915 915 915 915 915
Depth mm 155 155 155 155 155 155
Weight kg 11 11 11 11 11 11
Sound Pressure High / Low dBA 38 / 25 42 / 26 45 / 35 38 / 25 42 / 26 45 / 35
Sound Power dBA 54 58 60 54 58 60
Outdoor Units RXG25K RXG35K RXG50K RXG25K RXG35K RXG50K
Dimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 550 x 765 x 285 735 x 825 x 300
Weight kg 34 34 48 34 34 48
Electrical Details Power Supply 1ph 1ph
Running Current A 2.98 4.78 6.90 2.98 4.78 6.90
Starting Current A 4.4 5.6 7.4 4.4 5.6 7.4
Max Fuse Size A 16 16 20 16 16 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2
Pipework Maximum Length m 20 20 30 20 20 30
Maximum Vertical Rise m 15 15 20 15 15 20
Precharged to m 10 10 10 10 10 10
Additional Charge g/m 20.0 20.0
Holding Charge kg 1.1 1.1 1.6 1.1 1.1 1.6
Sound Pressure High dBA 46 48 48 46 48 48
Sound Power dBA 46 48 48 46 48 48
Trade Fan Coil Price 271.00 304.00 464.00 323.00 362.00 554.00
Trade Condensing Unit Price 494.00 574.00 918.00 494.00 574.00 918.00
Total System Price 765.00 878.00 1,382.00 817.00 936.00 1,472.00
Features:
Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round
It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efcient cooling
Stylish, low-profle design
Sound pressure performance down to 22 dB(A)
Weekly schedule timer on the standard wireless remote controller allows programming of the unit on a weekly basis,
with the ability to schedule dierent settings for each day of the week, up to 4 actions per day possible
Special anti-corrosion treatment of the fan and the heat exchanger of the outdoor unit
Pair and multi applications (up to 9 indoor units can be connected to a single multi condenser)
Intelligent Eye Presence Sensor, switches to energy saving mode if room is unoccupied after 20 mins
Comfort mode: guarantees draught free operation, directing warm air down and cold air horizontally
Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
Re-use of existing R22 & R407C piping possible
Accessory Ref Description Trade Price
BRC944 Optional Wired Remote controller 62.00
BRCW901A03 3m connection cable for BRC944 16.00
BRCW901A08 8m connection cable for BRC944 21.00
KRP413A1S Adaptor PCB for remote on/of control - constant/pulse contact 73.00
KRP928A2S Adaptor PCB for interface to Daikin centralised control systems 129.00
KLIC-DD KNX interface for Split type systems 160.00
RTD-RA Adaptor PCB for Modbus connection and/or extended system functions 156.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories: Notes:
i) All fan coil units standard with auto restart
after power failure
ii) All fan coils supplied as standard with
infrared remote controller
iii) FTXG-JW with matt crystal white casing,
FTXG-JA supplied with aluminium casing
iv) Wired controller, KLIC-DI and RTD-RA
options cannot be combined
v) Minimum ambient operating
temperatures:
Cooling Heating
RXG -10C -15C
Integrated Solutions 10
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Wall Mounted Inverter
FTXS-K/G
Indoor Units FTXS20K FTXS25K FTXS35K FTXS42K FTXS50K FTXS60G FTXS71G
Capacity UK Total Cooling kW 1.95 2.44 3.42 4.11 4.56 5.86 6.94
UK Sensible Cooling kW 1.65 1.82 2.56 2.85 3.14 3.87 4.65
Nominal Cooling kW 2.00 2.50 3.50 4.20 5.00 6.00 7.10
Nominal Heating kW 2.50 3.40 4.00 5.40 5.80 7.00 8.20
Seasonal Efciency
(EN14825)
COOLING
Energy Label A+ A++ A++ A++ A++ A A
Pdesign kW 2.00 2.50 3.50 4.20 5.00 6.00 7.10
SEER 5.71 6.37 6.97 6.60 6.60 5.35 5.23
Annual Energy Consumption kWh 123 137 176 223 265 393 475
Seasonal Efciency
(EN14825)
HEATING
Energy Label A++ A++ A++ A+ A+ A A
Pdesign kW 2.30 2.50 3.60 4.00 4.60 4.80 6.50
SCOP 4.75 4.63 4.71 4.09 4.10 3.75 3.50
Annual Energy Consumption kWh 678 756 1071 1371 1571 1790 2593
Nominal Efciency EER / COP 4.65 / 4.55 4.39 / 4.52 4.17 / 4.76 3.56 / 4.12 3.55 / 4 3.02 / 3.43 3.02 / 3.22
Energy Label A / A A / A A / A A / A A / A B / B B / C
Annual Energy Consumption kWh 215 285 420 590 705 995 1175
Air Flow Rate High / Low m
3
/min 8.8 / 4.7 9.1 / 5 11.2 / 5.8 11.2 / 7 11.9 / 7.4 16 / 11.3 17.2 / 11.5
Dimensions Height mm 289 289 298 298 298 290 290
Width mm 780 780 900 900 900 1050 1050
Depth mm 215 215 215 215 215 250 250
Weight kg 8 8 11 11 11 12 12
Sound Pressure High / Low dBA 40 / 24 41 / 25 45 / 29 45 / 33 46 / 34 45 / 36 46 / 37
Sound Power dBA 58 58 59 59 60 61 62
Outdoor Units RXS20K RXS25K RXS35K RXS42K RXS50K RXS60F RXS71F
Dimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 770 x 900 x 320
Weight kg 34 34 34 39 47 48 71
Electrical Details Power Supply 1ph 1ph
Running Current A 2.30 3.10 4.10 5.70 6.30 8.78 10.49
Starting Current A 2.8 3.3 4.3 6.6 6.8 9.4 11.7
Max Fuse Size A 10 10 10 20 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 1/4 / 5/8
Pipework Maximum Length m 20 20 20 20 30 30 30
Maximum Vertical Rise m 15 15 15 15 20 20 20
Precharged to m 10 10 10 10 10 10 10
Additional Charge g/m 20.0 20.0
Holding Charge kg 1.0 1.0 1.2 1.3 1.7 1.5 2.3
Sound Pressure High dBA 46 46 48 48 48 49 52
Sound Power dBA 46 46 48 48 48 49 52
Trade Fan Coil Price 151.00 162.00 185.00 208.00 288.00 294.00 392.00
Trade Condensing Unit Price 427.00 467.00 541.00 611.00 680.00 725.00 993.00
Total System Price 578.00 629.00 726.00 819.00 968.00 1,019.00 1,385.00
Features:
Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible
Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops
Titanium apatite photocatalytic air purifying flter: superior purifcation and deodorisation of the air inside the room
2-area intelligent eye: (25~50 K class) air fow is sent to a zone other than where the occupants are located at that moment
Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins
Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
Fan speed: 5 fan speeds can be selected, high to super low
Suitable for multi model applications
Re-use of existing R22 and R407C piping possible
Accessory Ref Description Trade Price
KRP980A1 Adaptor for FTXS20 & 25K needed for all control options 66.00
BRC944 Optional Wired Remote controller 62.00
BRCW901A03 3m connection cable for BRC944 16.00
BRCW901A08 8m connection cable for BRC944 21.00
KRP928A2S Adaptor PCB for interface to Daikin centralised control systems / remote on-of / constant pulse 129.00
KLIC-DD KNX interface for Split type systems 160.00
RTD-RA Adaptor PCB for Modbus connection and/or extended system functions 156.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories: Notes:
i) All fan coil units standard with auto restart
after power failure
ii) All fan coils supplied as standard with
infrared remote controller
iii) Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv) Minimum ambient operating
temperatures:
Cooling Heating
RXS -10C -15C
Price List 2013 11
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Wall Mounted Low Inverter
FTX-J/G
Indoor Units FTX20JV FTX25JV FTX35JV FTX50GV FTX60GV FTX71GV
Capacity UK Total Cooling kW 1.95 2.44 3.07 4.89 5.86 6.94
UK Sensible Cooling kW 1.60 1.78 2.11 3.32 3.88 4.48
Nominal Cooling kW 2.00 2.50 3.30 5.00 6.00 7.10
Nominal Heating kW 2.50 2.80 3.50 5.80 7.00 8.20
Seasonal Efciency
(EN14825)
COOLING
Energy Label A+ A+ A+ A+ A B
Pdesign kW 2.00 2.50 3.30 5.00 6.00 7.10
SEER 5.63 5.63 5.66 5.63 5.10 4.93
Annual Energy Consumption kWh 124 155 204 311 412 504
Seasonal Efciency
(EN14825)
HEATING
Energy Label A++ A+ A+ A+ A A
Pdesign kW 2.20 2.40 2.80 4.60 4.80 6.50
SCOP 4.67 4.50 4.14 4.08 3.74 3.45
Annual Energy Consumption kWh 659 746 945 1577 1795 2634
Nominal Efciency EER / COP 3.64 / 4.24 3.42 / 4.06 3.37 / 3.76 3.23 / 3.63 3.02 / 3.43 3.02 / 3.22
Energy Label A / A A / A A / A A / A B / B B / C
Annual Energy Consumption kWh 275 365 490 775 995 1175
Air Flow Rate High / Low m
3
/min 9.1 / 5.9 9.2 / 6 9.3 / 6.1 14.7 / 10.3 16.2 / 11.4 17.4 / 11.6
Dimensions Height mm 283 283 283 290 290 290
Width mm 770 770 770 1050 1050 1050
Depth mm 198 198 198 238 238 238
Weight kg 7 7 7 12 12 12
Sound Pressure High / Low dBA 39 / 25 40 / 26 41 / 27 43 / 34 45 / 36 46 / 37
Sound Power dBA 55 56 57 62 61 62
Outdoor Units RX20JV RX25JV RX35JV RX50GV RX60GV RX71GV
Dimensions Height x Width x Depth mm 550 x 658 x 275 735 x 825 x 300 770 x 900 x 320
Weight kg 28 28 30 48 48 71
Electrical Details Power Supply 1ph 1ph
Running Current A 2.49 3.49 4.99 6.83 8.78 10.49
Starting Current A 2.7 3.7 5.0 7.4 9.4 TBC
Max Fuse Size A 16 16 16 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 2.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 1/4 / 5/8
Pipework Maximum Length m 15 15 15 30 30 30
Maximum Vertical Rise m 12 12 12 20 20 20
Precharged to m 10 10 10 10 10 10
Additional Charge g/m 20.0 20.0
Holding Charge kg 0.7 0.7 1.0 1.5 1.5 1.5
Sound Pressure High dBA 46 46 48 47 49 52
Sound Power dBA 46 46 48 47 49 52
Trade Fan Coil Price 121.00 133.00 151.00 245.00 250.00 334.00
Trade Condensing Unit Price 357.00 381.00 444.00 578.00 617.00 886.00
Total System Price 478.00 514.00 595.00 823.00 867.00 1,220.00
Features:
Wireless remote controller with daily timer
Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops
Titanium apatite photocatalytic air purifying flter: superior purifcation and deodorisation of the air inside the room
Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
Fan speed: 5 fan speeds can be selected, high to super low
Suitable for multi model applications
Re-use of existing R22 and R407C piping possible
Accessory Ref Description Trade Price
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories: Notes:
i) All fan coil units standard with auto restart
after power failure
ii) All fan coils supplied as standard with
infrared remote controller
iii) Minimum ambient operating
temperatures:
Cooling Heating
RX-JV +10C -15C
RX-GV -10C -15C
Integrated Solutions 12
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Wall Mounted
Seasonal Smart Inverter FAQ-C / RZQG
Indoor Units Single Phase 3 Phase
FAQ71C FAQ100C FAQ71C FAQ100C
Capacity UK Total Cooling kW 7.76 10.80 7.76 10.80
UK Sensible Cooling kW 5.32 7.44 5.32 7.44
Nominal Cooling kW 6.80 9.50 6.80 9.50
Nominal Heating kW 7.50 10.80 7.50 10.80
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A++ A++ A++
Pdesign kW 6.80 9.50 6.80 9.50
SEER 6.51 6.11 6.51 6.11
Annual Energy Consumption kWh 366 545 366 545
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A+ A+ A+
Pdesign kW 6.33 10.20 6.33 10.20
SCOP 4.02 4.01 4.02 4.01
Annual Energy Consumption kWh 2205 3560 2205 3560
Nominal Efciency EER / COP 3.4 / 3.7 3.62 / 3.61 3.4 / 3.7 3.62 / 3.61
Energy Label A / A A / A A / A A / A
Annual Energy Consumption kWh 1000 1315 1000 1315
Air Flow Rate High / Low m
3
/min 18 / 14 26 / 19 18 / 14 26 / 19
Dimensions Height mm 290 340 290 340
Width mm 1050 1200 1050 1200
Depth mm 238 240 238 240
Weight kg 13 17 13 17
Sound Pressure High / Low dBA 45 / 40 49 / 41 45 / 40 49 / 41
Sound Power dBA 61 41 61 41
Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG71L8Y1 RZQG100L8Y1
Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 78 102 80 101
Electrical Details Power Supply 1ph 3ph
Running Current A 9.25 12.16 3.07 4.04
Starting Current A 4 4 4 4
Max Fuse Size A 20 32 16 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 50 75 50 75
Maximum Vertical Rise m 30 30 30 30
Precharged to m 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.9 4.0 2.9 4.0
Sound Pressure High dBA 48 50 48 50
Sound Power dBA 48 50 48 50
Trade Fan Coil Price 783.00 846.00 783.00 846.00
Trade Condensing Unit Price 1,168.00 1,484.00 1,203.00 1,553.00
Total System Price 1,951.00 2,330.00 1,986.00 2,399.00
Features:
Fan speed: 3 fan speeds available on all capacities
Automatic airfow volume control sets fan speed based on diference between set and room temperatures
Dry programme: Daikins special dry programme reduces humidity in the rooms without variations in internal temperature
Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
Selectable evaporating & condensing temperature for greater operating efciency and application fexibility (Seasonal Smart)
DIII net compatibility as standard
Seasonally Efcient Inverter Technology gives up to 25% better efciency than inverter technology
Re-use of existing R22 and R407C piping possible. (See R22 Replacement leafet)
Suitable for Twin, Triple and Double Twin applications
Accessory Ref Description Trade Price
BRC7EB518 Wireless remote controller 132.00
KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 89.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
KRCS01-4 Remote room mounted temperature sensor 46.00
K.RSS Wireless room mounted temperature sensor and receiver 91.00
RS-SE Service and Confguration Tool for K.RSS 87.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
Accessories: Notes:
i) BRC7EB518 Trade price will be reduced by
74.00 if ordered at the same time as the
fan coil unit
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iv) Minimum ambient operating
temperatures:
Cooling Heating
RZQG -15C -20C
RZQSG -5C -15C
Price List 2013 13
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Wall Mounted
Seasonal Classic Inverter FAQ-C / RZQSG
Indoor Units Single Phase 3 Phase
FAQ71C FAQ100C FAQ100C
Capacity UK Total Cooling kW 7.28 10.80 10.80
UK Sensible Cooling kW 4.99 7.44 7.44
Nominal Cooling kW 6.80 9.50 9.50
Nominal Heating kW 7.50 10.80 10.80
Seasonal Efciency
(EN14825)
COOLING
Energy Label A+ A+ A+
Pdesign kW 6.80 9.50 9.50
SEER 6.05 5.61 5.61
Annual Energy Consumption kWh 394 593 593
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A+ A+
Pdesign kW 6.00 6.81 6.81
SCOP 3.90 4.01 4.01
Annual Energy Consumption kWh 2155 2376 2376
Nominal Efciency EER / COP 3.21 / 3.61 3.01 / 3.41 3.01 / 3.41
Energy Label A / A B / B B / B
Annual Energy Consumption kWh 1059 1580 1580
Air Flow Rate High / Low m
3
/min 18 / 14 26 / 19 26 / 19
Dimensions Height mm 290 340 340
Width mm 1050 1200 1200
Depth mm 238 240 240
Weight kg 13 17 17
Sound Pressure High / Low dBA 45 / 40 49 / 41 49 / 45
Sound Power dBA 61 65 41
Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG100L8Y1
Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 990 x 940 x 320
Weight kg 67 81 82
Electrical Details Power Supply 1ph 3ph
Running Current A 9.22 13.74 4.83
Starting Current A 4 4 4
Max Fuse Size A 20 32 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 30 50 50
Maximum Vertical Rise m 15 30 30
Precharged to m 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.75 2.9 2.9
Sound Pressure High dBA 49 53 53
Sound Power dBA 49 53 53
Trade Fan Coil Price 783.00 846.00 846.00
Trade Condensing Unit Price 864.00 1,196.00 1,232.00
Total System Price 1,647.00 2,042.00 2,078.00
Integrated Solutions 14
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Floor Mounted Inverter
Nexura
Indoor Units FVXG25K FVXG35K FVXG50K
Capacity UK Total Cooling kW 2.44 3.42 4.81
UK Sensible Cooling kW 1.93 2.37 3.17
Nominal Cooling kW 2.50 3.50 5.00
Nominal Heating kW 3.40 4.50 5.80
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A++ A
Pdesign kW 2.50 3.50 5.00
SEER 6.46 6.33 5.31
Annual Energy Consumption kWh 135 194 330
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A A
Pdesign kW 2.80 3.10 4.60
SCOP 4.47 3.87 4.08
Annual Energy Consumption kWh 877 1122 1577
Nominal Efciency EER / COP 4.55 / 4.36 3.68 / 3.72 3.29 / 3.67
Energy Label A / A A / A A / A
Annual Energy Consumption kWh 275 475 760
Air Flow Rate High / Low m
3
/min 8.9 / 5.3 9.1 / 5.3 10.6 / 7.3
Dimensions Height mm 600 600 600
Width mm 950 950 950
Depth mm 215 215 215
Weight kg 14 14 14
Sound Pressure High / Low dBA 38 / 26 39 / 27 44 / 36
Sound Power dBA 54 55 56
Outdoor Units RXG25K RXG35K RXG50K
Dimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300
Weight kg 34 34 48
Electrical Details Power Supply 1ph
Running Current A 2.90 4.60 6.70
Starting Current A 4.1 6.0 7.3
Max Fuse Size A 10 10 20
Interconnection Wiring Core / Cable size 3+E / 1.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2
Pipework Maximum Length m 20 20 30
Maximum Vertical Rise m 15 15 20
Precharged to m 10 10 10
Additional Charge g/m 20.0
Holding Charge kg 1.1 1.1 1.6
Sound Pressure High dBA 46 48 48
Sound Power dBA 46 48 48
Trade Fan Coil Price 619.00 666.00 729.00
Trade Condensing Unit Price 494.00 574.00 918.00
Total System Price 1,113.00 1,240.00 1,647.00
Features:
Radiant Heat panel provides radiator-like warming at the touch of a button
Energy efcient units: full range A class energy labels
Wireless remote controller provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 4 actions per day
Titanium apatite photocatalytic air purifying flter: superior purifcation and deodorisation of the air inside the room
Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
Extremely quiet in operation: down to 19dBA sound pressure level
Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops,
so you can sleep more comfortably
Vertical auto swing system automatically makes the louvers move up and down, creating an even distribution of air through the room to
ensure a harmonized temperature
Flexible installation: Can be installed against a wall, recessed or standing on the foor (installation leg required, see accessories list).
Ideal for installation beneath a window
Suitable for multi model applications
Re-use of existing R22 and R407 piping possible
Accessory Ref Description Trade Price
BRC944 Optional Wired Remote controller 62.00
BRCW901A03 3m connection cable for BRC944 16.00
BRCW901A08 8m connection cable for BRC944 21.00
KRP413A1S Adaptor PCB for remote on/of control - constant/pulse contact 73.00
KRP928A2S Adaptor PCB for interface to Daikin centralised control systems 129.00
KLIC-DD KNX interface for Split type systems 160.00
RTD-RA Adaptor PCB for Modbus connection and/or extended system functions 156.00
BKS028 Leg for foor-standing installation 385.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories: Notes:
i) All fan coil units standard with auto restart
after power failure
ii) All fan coils supplied as standard with
infrared remote controller
iii) Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv) Minimum ambient operating
temperatures:
Cooling Heating
RXG -10C -15C
Price List 2013 15
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Floor Mounted Inverter
FVXS
Indoor Units FVXS25F FVXS35F FVXS50F
Capacity UK Total Cooling kW 2.44 3.42 4.89
UK Sensible Cooling kW 1.87 2.34 3.21
Nominal Cooling kW 2.50 3.50 5.00
Nominal Heating kW 3.40 4.50 5.80
Seasonal Efciency
(EN14825)
COOLING
Energy Label B B A
Pdesign kW 2.50 3.50 5.00
SEER 4.71 4.93 5.53
Annual Energy Consumption kWh 186 248 317
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A A
Pdesign kW 2.60 2.90 4.80
SCOP 4.38 3.83 3.62
Annual Energy Consumption kWh 830 1060 1853
Nominal Efciency EER / COP 4.39 / 4.3 3.43 / 3.69 3.23 / 3.63
Energy Label A / A A / A A / A
Annual Energy Consumption kWh 285 510 775
Air Flow Rate High / Low m
3
/min 8.2 / 4.8 8.5 / 4.9 10.7 / 7.8
Dimensions Height mm 600 600 600
Width mm 700 700 700
Depth mm 210 210 210
Weight kg 14 14 14
Sound Pressure High / Low dBA 38 / 26 39 / 27 44 / 36
Sound Power High dBA 54 55 56
Outdoor Units RXS25K RXS35K RXS50K
Dimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300
Weight kg 34 34 47
Electrical Details Power Supply 1ph
Running Current A 3.30 4.70 6.80
Starting Current A 3.3 4.3 6.8
Max Fuse Size A 10 10 20
Interconnection Wiring Core / Cable size 3+E / 1.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2
Pipework Maximum Length m 20 20 30
Maximum Vertical Rise m 15 15 20
Precharged to m 10 10 10
Additional Charge g/m 20.0
Holding Charge kg 1.0 1.2 1.7
Sound Pressure High dBA 46 48 48
Sound Power High dBA 46 48 48
Trade Fan Coil Price 513.00 553.00 604.00
Trade Condensing Unit Price 467.00 541.00 680.00
Total System Price 980.00 1,094.00 1,284.00
Features:
Extremely quiet, energy efcient and can be installed against the wall or recessed
Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible
Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops
Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
Titanium apatite photocatalytic air purifying flter: superior purifcation and deodorisation of the air inside the room
Dry programme: Daikins special dry programme reduces humidity in the rooms without variations in internal temperature
Suitable for multi model applications
Re-use of existing R22 and R407C piping possible
Accessory Ref Description Trade Price
KRP413A1S Adaptor PCB for remote on/of control - constant/pulse contact 73.00
KRP928A2S Adaptor PCB for interface to Daikin centralised control systems 129.00
KLIC-DD KNX interface for Split type systems 160.00
RTD-RA Adaptor PCB for Modbus connection and/or extended system functions 156.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories: Notes:
i) All fan coil units standard with auto restart
after power failure
ii) All fan coils supplied as standard with
infrared remote controller
iii) Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv) Minimum ambient operating
temperatures:
Cooling Heating
RXS -10C -15C
Integrated Solutions 16
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Floor Mounted Seasonal Smart Inverter
FVQ-C / RZQG
Indoor Units Single Phase 3 Phase
FVQ71C FVQ100C FVQ125C FVQ140C FVQ71C FVQ100C FVQ125C FVQ140C
Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90
UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A+ A+ - A++ A+ A+ -
Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -
SEER 6.31 5.61 5.61 - 6.31 5.61 5.61 -
Annual Energy Consumption kWh 378 593 749 - 378 593 749 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A+ A - A+ A+ A -
Pdesign kW 6.33 11.30 11.30 - 6.33 11.30 11.30 -
SCOP 4.05 4.20 3.87 - 4.05 4.20 3.87 -
Annual Energy Consumption kWh 2189 3769 4090 - 2189 3769 4090 -
Nominal Efciency EER / COP 3.37 / 3.64 3.81 / 4.14 3.21 / 3.7 3.21 / 3.61 3.37 / 3.64 3.81 / 4.14 3.21 / 3.7 3.21 / 3.61
Energy Label A / A A / A A / A A / A A / A A / A A / A A / A
Annual Energy Consumption kWh 1010 1245 1870 2085 1010 1245 1870 2085
Air Flow Rate High / Low m
3
/min 18 / 14 28 / 25 28 / 26 30 / 28 18 / 14 28 / 25 28 / 26 30 / 28
Dimensions Height mm 1850 1850 1850 1850 1850 1850 1850 1850
Width mm 600 600 600 600 600 600 600 600
Depth mm 270 350 350 350 270 350 350 350
Weight kg 39 47 47 47 39 47 47 47
Sound Pressure High / Low dBA 43 / 38 50 / 44 51 / 46 53 / 48 43 / 38 50 / 44 51 / 46 53 / 48
Sound Power dBA 55 62 63 65 55 62 63 65
Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Dimensions Height x Width x Depth mm 990 x 940
x 320
1430 x 940
x 320
1430 x 940
x 320
1430 x 940
x 320
990 x 940
x 320
1430 x 940
x 320
1430 x 940
x 320
1430 x 940
x 320
Weight kg 78 102 102 102 80 101 101 101
Electrical Details Power Supply 1ph 3ph
Running Current A 9.34 11.52 17.30 19.29 3.11 3.83 5.75 6.41
Starting Current A 4 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 16 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 50 75 75 75 50 75 75 75
Maximum Vertical Rise m 30 30 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0
Sound Pressure High dBA 48 50 51 52 48 50 51 52
Sound Power dBA 48 50 51 52 48 50 51 52
Trade Fan Coil Price 1,047.00 1,150.00 1,270.00 1,366.00 1,047.00 1,150.00 1,270.00 1,366.00
Trade Condensing Unit Price 1,168.00 1,484.00 1,633.00 1,864.00 1,203.00 1,553.00 1,709.00 1,963.00
Total System Price 2,215.00 2,634.00 2,903.00 3,230.00 2,250.00 2,703.00 2,979.00 3,329.00
Features:
Seasonally Efcient Inverter Technology gives up to 25% better efciency than Inverter Technology
Vertical air fow pattern can be adjusted manually to match requirements in diferent sized interiors or irregularly shaped rooms
A wired BRC1E52A remote controller is mounted on the front of the unit (standard)
Controllable horizontal air-blow patterns, via remote control
Very efcient for use in rooms with high ceilings
Fan speed: 2 fan speeds can be selected, high or low
Re-use of existing R22 and R407C piping possible
Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
Selectable evaporating & condensing temperature for greater operating efciency (Seasonal Smart)
DIII net compatibility as standard
Accessory Ref Description Trade Price
KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 89.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 347.00
Accessories: Notes:
i) All fan coil units standard with auto restart
after power failure
ii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iii) Minimum ambient operating
temperatures:
Cooling Heating
RZQG -15C -20C
RZQSG -5C -15C
Price List 2013 17
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Floor Mounted Seasonal Classic Inverter
FVQ-C / RZQSG
Indoor Units Single Phase 3 Phase
FVQ71C FVQ100C FVQ125C FVQ140C FVQ100C FVQ125C FVQ140C
Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90
UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A A A - A A -
Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -
SEER 5.50 5.50 5.50 - 5.50 5.50 -
Annual Energy Consumption kWh 433 605 764 - 605 764 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A A+ A+ - A+ A+ -
Pdesign kW 6.33 7.60 7.60 - 7.60 7.60 -
SCOP 3.86 4.01 4.21 - 4.01 4.21 -
Annual Energy Consumption kWh 2297 2553 2527 - 2553 2527 -
Nominal Efciency EER / COP 3.21 / 3.61 3.21 / 3.61 2.81 / 3.41 3.01 / 3.41 3.21 / 3.61 2.81 / 3.41 3.01 / 3.41
Energy Label A / A A / A C / B B / B A / A C / B B / B
Annual Energy Consumption kWh 1059 1480 2135 2225 1480 2135 2225
Air Flow Rate High / Low m
3
/min 18 / 14 28 / 25 28 / 26 30 / 28 28 / 25 28 / 26 30 / 28
Dimensions Height mm 1850 1850 1850 1850 1850 1850 1850
Width mm 600 600 600 600 600 600 600
Depth mm 270 350 350 350 350 350 350
Weight kg 39 47 47 47 47 47 47
Sound Pressure High / Low dBA 43 / 38 50 / 44 51 / 46 53 / 48 50 / 44 51 / 46 53 / 48
Sound Power dBA 55 62 63 65 62 63 65
Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 67 81 102 82 101
Electrical Details Power Supply 1ph 3ph
Running Current A 9.22 12.87 18.57 19.35 4.52 6.53 6.80
Starting Current A 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 30 50 50 50 50 50 50
Maximum Vertical Rise m 15 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0
Sound Pressure High dBA 49 53 54 53 53 54 53
Sound Power dBA 49 53 54 53 53 54 53
Trade Fan Coil Price 1,047.00 1,150.00 1,270.00 1,366.00 1,150.00 1,270.00 1,366.00
Trade Condensing Unit Price 864.00 1,196.00 1,312.00 1,461.00 1,232.00 1,351.00 1,505.00
Total System Price 1,911.00 2,346.00 2,582.00 2,827.00 2,382.00 2,621.00 2,871.00
Integrated Solutions 18
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Floor or Ceiling Mounted
Inverter FLXS
Indoor Units FLXS25B FLXS35B FLXS50B
Capacity UK Total Cooling kW 2.44 3.34 4.82
UK Sensible Cooling kW 1.65 2.14 3.16
Nominal Cooling kW 2.50 3.50 4.90
Nominal Heating kW 3.40 4.00 6.10
Seasonal Efciency
(EN14825)
COOLING
Energy Label C C B
Pdesign kW 2.50 3.50 4.90
SEER 4.46 4.49 5.09
Annual Energy Consumption kWh 196 273 337
Seasonal Efciency
(EN14825)
HEATING
Energy Label A A A
Pdesign kW 2.80 2.90 4.50
SCOP 3.63 3.42 3.68
Annual Energy Consumption kWh 1080 1186 1708
Nominal Efciency EER / COP 3.85 / 3.47 3.1 / 3.25 2.85 / 3.35
Energy Label A / B B / C C / C
Annual Energy Consumption kWh 325 565 860
Air Flow Rate High / Low m
3
/min 7.6 / 6 8.6 / 6.6 11.4 / 8.5
Dimensions Height mm 490 490 490
Width mm 1050 1050 1050
Depth mm 200 200 200
Weight kg 16 16 17
Sound Pressure High / Low dBA 37 / 31 38 / 32 47 / 39
Sound Power dBA 53 54 63
Outdoor Units RXS25K RXS35K RXS50K
Dimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300
Weight kg 34 34 47
Electrical Details Power Supply 1ph
Running Current A 3.60 5.10 7.60
Starting Current A 3.3 4.3 6.8
Max Fuse Size A 10 10 20
Interconnection Wiring Core / Cable size 3+E / 1.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2
Pipework Maximum Length m 20 20 30
Maximum Vertical Rise m 15 15 20
Precharged to m 10 10 10
Additional Charge g/m 20.0
Holding Charge kg 1.0 1.2 1.7
Sound Pressure High dBA 46 48 48
Sound Power dBA 46 48 48
Trade Fan Coil Price 369.00 415.00 450.00
Trade Condensing Unit Price 467.00 541.00 680.00
Total System Price 836.00 956.00 1,130.00
Features:
Can be installed EITHER as ceiling mounted OR wall unit
Vertical auto swing: faps automatically swing up and down to ensure efcient air and temperature distribution in both foor level and ceiling
suspended installation
Home Leave setting maintains pre-set temperature during periods of extended absence
Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops
Fan speed: 5 fan speeds can be selected, high to super low
Suitable for multi model applications
Re-use of existing R22 and R407C piping possible
Accessory Ref Description Trade Price
KRP413A1S Adaptor PCB for remote on/of control - constant/pulse contact 73.00
KRP928A2S Adaptor PCB for interface to Daikin centralised control systems 129.00
KLIC-DD KNX interface for Split type systems 160.00
RTD-RA Adaptor PCB for Modbus connection and/or extended system functions 156.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories: Notes:
i) All fan coil units standard with auto restart
after power failure
ii) All fan coils supplied as standard with
infrared remote controller
iii) Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv) Minimum ambient operating
temperatures:
Cooling Heating
RXS -10C -15C
Price List 2013 19
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Accessory Ref Description Trade Price
BRC7G53 Wireless remote controller 149.00
EKRORO4 Remote on/of control interface kit 15.00
KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 89.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DD KNX Interface for Sky Air and VRV systems 160.00
KRCS01-1 Remote room mounted temperature sensor 45.00
K.RSS Wireless room mounted temperature sensor and receiver 91.00
RS-SE Service and Confguration Tool for K.RSS 87.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
KDDQ50A140 Fresh Air Intake Kit (Max 10%) TBC
Ceiling Suspended Inverter
FHQ-C
Indoor Units FHQ35C FHQ50C FHQ60C
Capacity UK Total Cooling kW 3.32 4.89 5.62
UK Sensible Cooling kW 2.58 3.21 4.07
Nominal Cooling kW 3.40 5.00 5.70
Nominal Heating kW 4.00 6.00 7.20
Seasonal Efciency
(EN14825)
COOLING
Energy Label B A A
Pdesign kW 3.40 5.00 5.70
SEER 4.89 5.48 5.54
Annual Energy Consumption kWh 243 320 360
Seasonal Efciency
(EN14825)
HEATING
Energy Label A A A
Pdesign kW 3.10 4.35 5.07
SCOP 3.98 3.74 3.50
Annual Energy Consumption kWh 1090 1627 2026
Nominal Efciency EER / COP 3.58 / 3.96 3.18 / 3.35 3.26 / 3.32
Energy Label A / B A / C A / C
Annual Energy Consumption kWh 475 785 875
Air Flow Rate High / Low m
3
/min 14 / 10 15 / 10 19.5 / 15
Dimensions Height mm 235 235 235
Width mm 960 960 1270
Depth mm 690 690 690
Weight kg 24 25 31
Sound Pressure High / Low dBA 36 / 32 37 / 33 37 / 33
Sound Power dBA 53 54 54
Outdoor Units RXS35K RXS50K RXS60F
Dimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
Weight kg 34 47 48
Electrical Details Power Supply 1ph
Running Current A 5.12* 8.28* 9.68*
Starting Current A 4.3 6.8 9.4
Max Fuse Size A 10 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2
Pipework Maximum Length m 20 30 30
Maximum Vertical Rise m 15 20 20
Precharged to m 10 10 10
Additional Charge g/m 20.0
Holding Charge kg 1.2 1.7 1.5
Sound Pressure High dBA 48 48 49
Sound Power dBA 48 48 49
Trade Fan Coil Price 696.00 754.00 828.00
Trade Condensing Unit Price 541.00 680.00 725.00
Total System Price 1,237.00 1,434.00 1,553.00
Features:
Suitable for ceiling heights of up to 3.8m without loss of capacity
Vertical auto-swing function of faps ensures efcient air and temperature distribution
Forced of: The optional forced of feature enables the unit to switch of automatically, for example when a window is opened
Re-use of existing R22 and R407C piping possible
Suitable for Twin, Triple and Double Twin applications
Accessories: Notes:
i) BRC7G53 Trade price will be reduced by
74.00 if ordered at the same time as the
fan coil unit in place of the BRC1E52A
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iv) Data marked with * is preliminary
v) Minimum ambient operating
temperatures:
Cooling Heating
RXS -10C -15C
Integrated Solutions 20
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Ceiling Suspended Seasonal Smart Inverter
FHQ-C Seasonal Smart
Indoor Units Single Phase 3 Phase
FHQ71C FHQ100C FHQ125C FHQ140C FHQ71C FHQ100C FHQ125C FHQ140C
Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90
UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A+ A+ - A++ A+ A+ -
Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -
SEER 6.95 6.11 6.01 - 6.95 6.11 6.01 -
Annual Energy Consumption kWh 343 545 699 - 343 545 699 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A++ A+ - A+ A++ A+ -
Pdesign kW 7.60 11.30 14.13 - 7.60 11.30 14.13 -
SCOP 4.32 4.61 4.23 - 4.32 4.61 4.23 -
Annual Energy Consumption kWh 2462 3433 4677 - 2462 3433 4677 -
Nominal Efciency EER / COP 3.82 / 4.13 4.13 / 4.42 3.52 / 3.89 3.31 / 3.63 3.82 / 4.13 4.13 / 4.42 3.52 / 3.89 3.31 / 3.63
Energy Label A / A A / A A / A A / A A / A A / A A / A A / A
Annual Energy Consumption kWh 890 1245 1790 2025 890 1245 1790 2025
Air Flow Rate High / Low m
3
/min 20.5 / 14 28 / 20 31 / 23 34 / 24 20.5 / 14 28 / 20 31 / 23 34 / 24
Dimensions Height mm 235 235 235 235 235 235 235 235
Width mm 1270 1590 1590 1590 1270 1590 1590 1590
Depth mm 690 690 690 690 690 690 690 690
Weight kg 32 38 38 38 32 38 38 38
Sound Pressure High / Low dBA 38 / 34 42 / 34 44 / 37 46 / 38 38 / 34 42 / 34 44 / 37 46 / 38
Sound Power dBA 55* 60 62 64 55* 60 62 64
Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 78 102 80 101
Electrical Details Power Supply 1ph 3ph
Running Current A 8.23 11.52 16.56 18.73 2.74 3.83 5.50 6.23
Starting Current A 4 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 16 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 50 75 75 75 50 75 75 75
Maximum Vertical Rise m 30 30 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0
Sound Pressure High dBA 48 50 51 52 48 50 51 52
Sound Power dBA 48 50 51 52 48 50 51 52
Trade Fan Coil Price 969.00 1,030.00 1,289.00 1,532.00 969.00 1,030.00 1,289.00 1,532.00
Trade Condensing Unit Price 1,168.00 1,484.00 1,633.00 1,864.00 1,203.00 1,553.00 1,709.00 1,963.00
Total System Price 2,137.00 2,514.00 2,922.00 3,396.00 2,172.00 2,583.00 2,998.00 3,495.00
Features:
Suitable for ceiling heights of up to 3.8m without loss of capacity
Seasonally Efcient Inverter Technology gives up to 25% better efciency
than inverter technology
Forced of: The optional forced of enables the unit to switch of
automatically, for example when a window is opened
Re-use of existing R22 and R407C piping possible
Suitable for Twin, Triple and Double Twin applications
Comms, computer and server room cooling possible with
EDP setting (Seasonal Smart)
Selectable evaporating & condensing temperature for greater
operating eciency (Seasonal Smart)
DIII net compatibility as standard
Accessory Ref Description Trade Price
BRC7G53 Wireless remote controller 149.00
EKRORO4 Remote on/of control interface kit 15.00
KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 89.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
KRCS01-1 Remote room mounted temperature sensor 45.00
K.RSS Wireless room mounted temperature sensor and receiver 91.00
RS-SE Service and Confguration Tool for K.RSS 87.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
KDDQ50A140 Fresh Air Intake Kit (Max 10%) TBC
Accessories: Notes:
i) BRC7G53 Trade price will be reduced by
74.00 if ordered at the same time as the
fan coil unit in place of the BRC1E52A
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iv) Minimum ambient operating
temperatures:
Cooling Heating
RZQG -15C -20C
RZQSG -5C -15C
RXS -10C -15C
Price List 2013 21
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Ceiling Suspended Seasonal Classic Inverter
FHQ-C Seasonal Classic
Indoor Units Single Phase 3 Phase
FHQ71C FHQ100C FHQ125C FHQ140C FHQ100C FHQ125C FHQ140C
Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90
UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A+ A+ A+ - A+ A+ -
Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -
SEER 5.61 5.61 5.61 - 5.61 5.61 -
Annual Energy Consumption kWh 425 593 749 - 593 749 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A A A+ - A A+ -
Pdesign kW 7.60 7.60 7.60 - 7.60 7.60 -
SCOP 3.90 3.91 4.01 - 3.91 4.01 -
Annual Energy Consumption kWh 2727 2720 2653 - 2720 2653 -
Nominal Efciency EER / COP 3.46 / 4 3.21 / 3.61 2.89 / 3.62 3.01 / 3.41 3.21 / 3.61 2.89 / 3.62 3.01 / 3.41
Energy Label A / A A / A C / A B / B A / A C / A B / B
Annual Energy Consumption kWh 983 1480 2075 2225 1480* 2075* 2225*
Air Flow Rate High / Low m
3
/min 20.5 / 14 28 / 20 31 / 23 34 / 24 28 / 20 31 / 23 34 / 24
Dimensions Height mm 235 235 235 235 235 235 235
Width mm 1270 1590 1590 1590 1590 1590 1590
Depth mm 690 690 690 690 690 690 690
Weight kg 32 38 38 38 38 38 38
Sound Pressure High / Low dBA 38 / 34 42 / 34 44 / 37 46 / 38 42 / 34 44 / 37 46 / 38
Sound Power dBA 55 60 62 64 60 62 64
Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 67 81 102 82 101
Electrical Details Power Supply 1ph 3ph
Running Current A 8.57 12.87 18.04 19.35 4.52 6.34 6.80
Starting Current A 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 30 50 50 50 50 50 50
Maximum Vertical Rise m 15 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0
Sound Pressure High dBA 49 53 54 53 53 54 53
Sound Power dBA 49 53 54 53 53 54 53
Trade Fan Coil Price 969.00 1,030.00 1,289.00 1,532.00 1,030.00 1,289.00 1,532.00
Trade Condensing Unit Price 864.00 1,196.00 1,312.00 1,461.00 1,232.00 1,351.00 1,505.00
Total System Price 1,833.00 2,226.00 2,601.00 2,993.00 2,262.00 2,640.00 3,037.00
Integrated Solutions 22
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
your comfort. our world.
Designed with the installer in mind, the Fully Flat Cassette fits flush within
a standard European ceiling panel to reduce installation time. Daikins
market leading technology with intelligent sensors and the ability to
easily reconfigure the air flow makes set up extremely simple, while
delivering perfect comfort to your customers.

& Genius
in one
Design
Leading edge design
in tune with time
FFQ50C+RXS50K=A+/A+
Price List 2013 23
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
600x600 Fully Flat Cassette
FFQ (FFQ-C Series coming summer 2013. FFQ-B9V series available until then)
Features:
Installed into suspended ceiling grids without cutting surrounding tiles
Home Leave setting maintains pre-set temperature during periods of extended absence
Dry programme: Daikins special dry programme reduces humidity in the rooms without variations in internal temperature
Vertical auto-swing function: faps automatically swing up and down to ensure efcient air and temperature distribution which also prevents ceiling soiling
3 fan speeds can be selected: high, medium and low
Suitable for Twin, Triple and Double Twin applications. Also suitable for multi model applications
Re-use of existing R22 and R407C piping possible
Accessory Ref Description Trade Price
BYCQ60W Fully Flat decoration panel - white 194.00
BYCQ60S Fully Flat decoration panel - silver 194.00
BYCQ60B2 FFQ-B9V style decoration panel 139.00
BRYQ60AW Integral PIR sensor for White Fully Flat decoration panel. Enables energy saving functions 97.00
BRYQ60AS Integral PIR sensor for Silver Fully Flat decoration panel. Enables energy saving functions 97.00
BRC7E530 Wireless infrared controller 149.00
BRC7F530W Wireless infrared controller - white fnish to match white deco-panel 149.00
BRC7F530S Wireless infrared controller - silver fnish to match silver deco-panel 149.00
EKRORO2 Remote on/of control interface kit 28.00
KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 89.00
KRP1B57/UK.FB2 Adaptor PCB for Interlock to fresh air fan 97.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air & VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air: Duty rotation, lead lag control & heating interlock 229.00
RTD-20/UK.FB2 Energy Control for Sky Air POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
KRCSO1-4 Remote room mounted temperature sensor 45.00
K.RSS Wireless room mounted temperature sensor and receiver 91.00
RS-SE Service and Confguration Tool for K.RSS 87.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories: Notes:
i) *Data for all FFQ-C pairings is provisional
ii) BRC7E530 Trade price will be reduced by
74.00 if ordered at the same time as the
fan coil unit in place of the BRC1E52A
iii) All fan coil units standard with auto restart
after power failure
iv) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
v) All fan coils supplied as standard with
BYFQ60Q decoration panel. Silver panels
available at no extra cost if ordered at
same time as fan coil and in place of
BYFQ60W
vi) Fan-coil list price will be reduced by
55.00 if FFQ-B9V style deco-panel
ordered at same time as fan-coil and in
place of BYFQ60W
vii) Minimum ambient operating
temperatures:
Cooling Heating
RXS -10C -15C
Indoor Units FFQ25C* FFQ35C* FFQ50C* FFQ60C*
Capacity UK Total Cooling kW 2.44 3.32 4.62 5.72
UK Sensible Cooling kW 1.81 2.28 3.40 4.20
Nominal Cooling kW 2.50 3.40 4.70 5.80
Nominal Heating kW 3.20 4.00 5.50 7.00
Seasonal Efciency
(EN14825)
COOLING
Energy Label A A+ A+ A+
Pdesign kW 2.50 3.40 4.70 5.80
SEER 5.25 5.60 5.70 5.60
Annual Energy Consumption kWh 168 210 302 354
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A+ A+ A+
Pdesign kW 2.31 3.45 3.84 3.96
SCOP 4.12 4.09 4.10 4.17
Annual Energy Consumption kWh 728 1151 1316 1317
Nominal Efciency EER / COP 4.5 / 3.8 3.7 / 3.41 3.21 / 3.5 3.01 / 3.41
Energy Label A / A A / A A / B B / B
Annual Energy Consumption kWh 280 460 780 945
Air Flow Rate High / Low m
3
/min 9 / 6.5 10 / 6.5 12 / 7.5 14.5 / 9.5
Dimensions
(with Decoration Panel)
Height mm 260 (306) 260 (306) 260 (306) 260 (306)
Width mm 575 (620) 575 (620) 575 (620) 575 (620)
Depth mm 575 (620) 575 (620) 575 (620) 575 (620)
Weight (with Decoration Panel) kg 17.5 (20.2) 17.5 (20.2) 17.5 (20.2) 17.5 (20.2)
Sound Pressure High / Low dBA 31 / 25 34 / 25 39 / 27 43 / 32
Sound Power dBA 48 51 56 60
Outdoor Units RXS25K* RXS35K* RXS50K* RXS60F*
Dimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
Weight kg 34 34 47 48
Electrical Details Power Supply 1ph
Running Current A tbc tbc tbc tbc
Starting Current A 3.3 4.3 6.8 9.4
Max Fuse Size A 10 10 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2
Pipework Maximum Length m 20 20 30 30
Maximum Vertical Rise m 15 15 20 20
Precharged to m 10 10 10 10
Additional Charge g/m 20.0
Holding Charge kg 1.0 1.2 1.7 1.5
Sound Pressure High dBA 46 48 48 49
Sound Power dBA 46 48 48 49
Trade Fan Coil Price 649.00 712.00 786.00 832.00
Trade Condensing Unit Price 467.00 541.00 680.00 725.00
Total System Price 1,116.00 1,253.00 1,466.00 1,557.00
Integrated Solutions 24
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
High COP Roundfow Cassette
Seasonal Smart Inverter FCQHG / RZQG
Indoor Units Single Phase 3 Phase
FCQHG71F FCQHG100F FCQHG125F FCQHG140F FCQHG71F FCQHG100F FCQHG125F FCQHG140F
Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90
UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A++ A++ - A++ A++ A++ -
Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -
SEER 7.00 7.00 6.61 - 7.00 7.00 6.61 -
Annual Energy Consumption kWh 340 475 636 - 340 475 636 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A++ A++ - A+ A++ A++ -
Pdesign kW 7.60 11.30 12.66 - 7.60 11.30 12.66 -
SCOP 4.54 4.80 4.63 - 4.54 4.80 4.63 -
Annual Energy Consumption kWh 2343 3298 3829 - 2343 3298 3829 -
Nominal Efciency EER / COP 4.09 / 4.8 4.42 / 4.99 4 / 4.4 3.35 / 4.12 4.09 / 4.8 4.42 / 4.99 4 / 4.4 3.35 / 4.14
Energy Label A / A A / A A / A A / A A / A A / A A / A A / A
Annual Energy Consumption kWh 830 1075 1500 2000 830] 1075 1500 2000
Air Flow Rate High / Low m
3
/min 21.2 / 12.2 32.3 / 19 33.5 / 19.9 33.2 / 21.1 21.2 / 12.2 32.3 / 19 33.5 / 19.9 33.2 / 21.1
Dimensions
(with Decoration Panel)
Height mm 288(348) 288 (348) 288 (348) 288 (348) 288(348) 288 (348) 288 (348) 288 (348)
Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Weight (with Decoration Panel) kg 25 (30.5) 26 (31.4) 26 (31.4) 26 (31.4) 25 (30.5) 26 (31.4) 26 (31.4) 26 (31.4)
Sound Pressure High / Low dBA 36 / 29 44 / 33 45 / 35 45 / 37 36 / 29 44 / 33 45 / 35 45 / 37
Sound Power dBA 53 61 61 61 53 61 61 61
Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 78 102 80 101
Electrical Details Power Supply 1ph 3ph
Running Current A 7.68 9.94 13.88 18.50 2.55 3.31 4.61 6.15
Starting Current A 4 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 16 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 50 75 75 75 50 75 75 75
Maximum Vertical Rise m 30 30 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0
Sound Pressure High dBA 48 50 51 52 48 50 51 52
Sound Power dBA 48 50 51 52 48 50 51 52
Trade Fan Coil Price 812.00 921.00 1,007.00 1,214.00 812.00 921.00 1,007.00 1,214.00
Trade Condensing Unit Price 1,168.00 1,484.00 1,633.00 1,864.00 1,203.00 1,553.00 1,709.00 1,963.00
Total System Price 1,980.00 2,405.00 2,640.00 3,078.00 2,015.00 2,474.00 2,716.00 3,177.00
Features:
The FCQHG model is designed for 2014 ErP regulations and has one of the highest COP values on the market
The unique 360 radial air pattern ensures uniform air fow and temperature distribution
Air fow fexibility: a wide selection of 23 diferent air fow patterns accessible via remote controller
Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels
Optional Self Cleaning Filter The BYCQ140DG decoration panel can ofer energy savings, reduced maintenance time and cost
Optional Fresh Air intake (up to 20%) possible
Suitable for Twin, Triple and Double Twin applications
Re-use of existing R22 and R407C piping possible
Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
Selectable evaporating & condensing temperature for greater operating efciency (Seasonal Smart)
DIII net compatibility as standard
Accessory Ref Description Trade Price
BRC7FA532F Wireless remote controller 149.00
BYCQ140DG Roundfow cassette decoration panel with self cleaning flter 303.00
BYCQ140DW Roundfow cassette decoration panel - white with white louvres 156.00
BRYQ140A Integral PIR Sensor for Roundfow decoration panel. Enables Energy Saving functions 97.00
KDBHQ55B140 Sealing member for air discharge outlet 88.00
KDDQ55B140 1/2 Fresh air intake kit for up to 20% fresh air (not compatible with self cleaning deco-panel) 440.00
KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 89.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
KRCS01-4 Remote room mounted temperature sensor 46.00
K.RSS Wireless room mounted temperature sensor and receiver 91.00
RS-SE Service and Confguration Tool for K.RSS 87.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
Accessories: Notes:
i) BRC7FA532F Trade price will be reduced
by 74.00 if ordered at the same time as
the fan coil unit in place of the BRC1E52A
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iv) All fan coils supplied as standard with
BYCQ140D Decoration panel
v) BYCQ140DW / BYCQ140DG Trade prices
will be reduced by 139.00 if ordered at
the same time as a fan coil in place of
standard decoration panel
vi) Minimum ambient operating
temperatures:
Cooling Heating
RZQG -15C -20C
RZQSG -5C -15C
RXS -10C -15C
Price List 2013 25
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
High COP Roundfow Cassette
Seasonal Classic Inverter FCQHG / RZQSG
Indoor Units Single Phase 3 Phase
FCQHG71F FCQHG100F FCQHG125F FCQHG140F FCQHG100F FCQHG125F FCQHG140F
Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90
UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A++ A - A++ A -
Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -
SEER 6.50 6.70 5.40 - 6.70 5.40 -
Annual Energy Consumption kWh 367 497 778 - 497 778 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A+ A+ - A+ A+ -
Pdesign kW 7.60 8.03 8.03 - 8.03 8.03 -
SCOP 4.15 4.30 4.10 - 4.30 4.10 -
Annual Energy Consumption kWh 2563 2614 2741 - 2614 2741 -
Nominal Efciency EER / COP 3.5 / 4.1 3.7 / 4.3 3.23 / 3.75 3.21 / 3.61 3.7 / 4.3 3.23 / 3.75 3.21 / 3.61
Energy Label A / A A / A A / A A / A A / A A / A A / A
Annual Energy Consumption kWh 1059 1285 1855 2085 1285 1855 2085
Air Flow Rate High / Low m
3
/min 21.2 / 12.2 32.3 / 19 33.5 / 19.9 45 / 37 32.3 / 19 33.5 / 19.9 45 / 37
Dimensions
(with Decoration Panel)
Height mm 288(348) 288 (348) 288 (348) 288 (348) 288 (348) 288 (348) 288 (348)
Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Weight (with Decoration Panel) kg 25 (30.5) 26 (31.4) 26 (31.4) 26 (31.4) 26 (31.4) 26 (31.4) 26 (31.4)
Sound Pressure High / Low dBA 36 / 29 44 / 33 45 / 35 45 / 37 44 / 33 45 / 35 45 / 37
Sound Power dBA 53 61 61 61 61 61 61
Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 67 81 102 82 101
Electrical Details Power Supply 1ph 3ph
Running Current A 8.43 11.17 16.13 18.13 3.93 5.67 6.37
Starting Current A 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 30 50 50 50 50 50 50
Maximum Vertical Rise m 15 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0
Sound Pressure High dBA 49 53 54 53 53 54 53
Sound Power dBA 49 53 54 53 53 54 53
Trade Fan Coil Price 812.00 921.00 1,007.00 1,214.00 921.00 1,007.00 1,214.00
Trade Condensing Unit Price 864.00 1,196.00 1,312.00 1,461.00 1,232.00 1,351.00 1,505.00
Total System Price 1,676.00 2,117.00 2,319.00 2,675.00 2,153.00 2,358.00 2,719.00
Self Cleaning Panel
Daikins Roundow Cassette can be equipped with a special lter that cleans
itself once a day, ensuring consistent, optimum performance.
Result?
Efciency gains up to 50% compared to standard panels.*
The dust collected during daily auto-cleaning is stored in
a dust box that can hold up to 12 months of dust, with an
indicator light showing when to clean the dust box. Under
normal circumstances, annual or bi-annual cleaning by in-house
maintenance personnel using an ordinary vacuum cleaner is
all that is needed: no ladders, no need to touch the cassette
panel or come in contact with the dust.
* Reference: Coral, Wolverhampton case study.
Integrated Solutions 26
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Compact Roundfow Cassette
Seasonal Smart Inverter FCQG / RZQG
Indoor Units Single Phase 3 Phase
FCQG71F FCQG100F FCQG125F FCQG140F FCQG71F FCQG100F FCQG125F FCQG140F
Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90
UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A++ A+ - A++ A++ A+ -
Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -
SEER 6.80 6.80 6.00 - 6.80 6.80 6.00 -
Annual Energy Consumption kWh 350 489 700 - 350 489 700 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A++ A+ - A+ A++ A+ -
Pdesign kW 6.33 11.30 12.66 - 6.33 11.30 12.66 -
SCOP 4.20 4.61 4.10 - 4.20 4.61 4.10 -
Annual Energy Consumption kWh 2111 3433 4324 - 2111 3433 4324 -
Nominal Efciency EER / COP 3.39 / 3.97 3.87 / 4.15 3.73 / 3.63 3.21 / 3.61 3.39 / 3.97 3.87 / 4.15 3.73 / 3.63 3.21 / 3.61
Energy Label A / A A / A A / A A / A A / A A / A A / A A / A
Annual Energy Consumption kWh 1005 1225 1610 2085 1005 1225 1610 2085
Air Flow Rate High / Low m
3
/min 15 / 9.1 22.8 / 12.4 26 / 12.4 26 / 12.4 15 / 9.1 22.8 / 12.4 26 / 12.4 26 / 12.4
Dimensions
(with Decoration Panel)
Height mm 204 (264) 246 (306) 246 (306) 246 (306) 204 (264) 246 (306) 246 (306) 246 (306)
Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Weight (with Decoration Panel) kg 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4) 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4)
Sound Pressure High / Low dBA 33 / 28 37 / 29 41 / 29 41 / 29 33 / 28 37 / 29 41 / 29 41 / 29
Sound Power dBA 51 54 58 58 51 54 58 58
Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 78 102 80 101
Electrical Details Power Supply 1ph 3ph
Running Current A 9.30 11.33 14.89 19.29 3.09 3.77 4.95 6.41
Starting Current A 4 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 16 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 50 75 75 75 50 75 75 75
Maximum Vertical Rise m 30 30 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0
Sound Pressure High dBA 48 50 51 52 48 50 51 52
Sound Power dBA 48 50 51 52 48 50 51 52
Trade Fan Coil Price 812.00 921.00 1,007.00 1,214.00 812.00 921.00 1,007.00 1,214.00
Trade Condensing Unit Price 1,168.00 1,484.00 1,633.00 1,864.00 1,203.00 1,553.00 1,709.00 1,963.00
Total System Price 1,980.00 2,405.00 2,640.00 3,078.00 2,015.00 2,474.00 2,716.00 3,177.00
Features:
FCQG is a compact cassette designed to suit installation in narrower ceiling voids
The unique 360 radial air pattern ensures uniform air fow and temperature distribution
Air fow fexibility: a wide selection of 23 diferent air fow patterns accessible via remote controller
Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels
Optional Self Cleaning Filter: The BYCQ140DG decoration panel can ofer energy savings, reduced maintenance time and cost
Optional Fresh Air intake (up to 20%) possible
Re-use of existing R22 and R407C piping possible
Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
Selectable evaporating & condensing temperature for greater operating efciency (Seasonal Smart)
DIII net compatibility as standard
Accessories: Notes:
i) BRC7FA532F Trade price will be reduced
by 74.00 if ordered at the same time as
the fan coil unit in place of the BRC1E52A
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iv) All fan coils supplied as standard with
BYCQ140D Decoration panel
v) BYCQ140DW / BYCQ140DG Trade prices
will be reduced by 139.00 if ordered at
the same time as a fan coil in place of
standard decoration panel
vi) Minimum ambient operating
temperatures:
Cooling Heating
RZQG -15C -20C
RZQSG -5C -15C
RXS -10C -15C
Accessory Ref Description Trade Price
BRC7FA532F Wireless remote controller 149.00
BYCQ140DG Roundfow cassette decoration panel with self cleaning flter 303.00
BYCQ140DW Roundfow cassette decoration panel - white with white louvres 156.00
BRYQ140A Integral PIR Sensor for Roundfow decoration panel. Enables Energy Saving functions 97.00
KDBHQ55B140 Sealing member for air discharge outlet 88.00
KDDQ55B140 1/2 Fresh air intake kit for up to 20% fresh air (not compatible with self cleaning deco-panel) 440.00
KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 89.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
KRCS01-4 Remote room mounted temperature sensor 46.00
K.RSS Wireless room mounted temperature sensor and receiver 91.00
RS-SE Service and Confguration Tool for K.RSS 87.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
Price List 2013 27
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Compact Roundfow Cassette
Seasonal Classic Inverter FCQG / RZQSG
Indoor Units Single Phase 3 Phase
FCQG71F FCQG100F FCQG125F FCQG140F FCQG100F FCQG125F FCQG140F
Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90
UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A+ A++ A - A++ A -
Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -
SEER 6.10 6.50 5.30 - 6.50 5.30 -
Annual Energy Consumption kWh 391 512 793 - 512 793 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A+ B - A+ B -
Pdesign kW 6.33 7.60 8.03 - 7.60 8.03 -
SCOP 4.10 4.10 3.41 - 4.10 3.41 -
Annual Energy Consumption kWh 2162 2799 2803 - 2799 2803 -
Nominal Efciency EER / COP 3.21 / 3.61 3.3 / 3.54 3.21 / 3.41 3.01 / 3.41 3.21 / 3.54 3.21 / 3.41 3.01 / 3.41
Energy Label A / A A / A A / B B / B A / A A / B B / B
Annual Energy Consumption kWh 971 1440 1870 1725 1440 1870 1725
Air Flow Rate High / Low m
3
/min 15 / 9.1 22.8 / 12.4 26 / 12.4 26 / 12.4 22.8 / 12.4 26 / 12.4 26 / 12.4
Dimensions
(with Decoration Panel)
Height mm 204 (264) 246 (306) 246 (306) 246 (306) 246 (306) 246 (306) 246 (306)
Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Weight (with Decoration Panel) kg 21 (26.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4) 24 (29.4)
Sound Pressure High / Low dBA 33 / 28 37 / 29 41 / 29 41 / 29 37 / 29 41 / 29 41 / 29
Sound Power dBA 51 54 58 58 54 58 58
Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 67 81 102 82 101
Electrical Details Power Supply 1ph 3ph
Running Current A 9.22 12.52 16.26 19.35 4.40 5.72 6.80
Starting Current A 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 30 50 50 50 50 50 50
Maximum Vertical Rise m 15 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0
Sound Pressure High dBA 49 53 54 53 53 54 53
Sound Power dBA 49 53 54 53 53 54 53
Trade Fan Coil Price 812.00 921.00 1,007.00 1,214.00 921.00 1,007.00 1,214.00
Trade Condensing Unit Price 864.00 1,196.00 1,312.00 1,461.00 1,232.00 1,351.00 1,505.00
Total System Price 1,676.00 2,117.00 2,319.00 2,675.00 2,153.00 2,358.00 2,719.00
Integrated Solutions 28
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Compact Roundfow Cassette Inverter
FCQG / RXS
Indoor Units FCQG35F FCQG50F FCQG60F
Capacity UK Total Cooling kW 3.32 4.89 5.57
UK Sensible Cooling kW 2.29 3.26 3.67
Nominal Cooling kW 3.40 5.00 5.70
Nominal Heating kW 4.20 6.00 7.00
Seasonal Efciency
(EN14825)
COOLING
Energy Label A A+ A+
Pdesign kW 3.40 5.00 5.70
SEER 5.34 5.89 5.74
Annual Energy Consumption kWh 230 297 347
Seasonal Efciency
(EN14825)
HEATING
Energy Label A++ A+ A
Pdesign kW 3.32 4.36 4.71
SCOP 4.74 4.24 3.87
Annual Energy Consumption kWh 981 1442 1704
Nominal Efciency EER / COP 3.58 / 3.41 3.55 / 3.7 3.48 / 3.52
Energy Label A / B A / A A / B
Annual Energy Consumption kWh 475 705 820
Air Flow Rate High / Low m
3
/min 12.5 / 8.7 12.6 / 8.7 13.6 / 8.7
Dimensions
(with Decoration Panel)
Height mm 204 (254) 204 (254) 204 (254)
Width mm 840 (950) 840 (950) 840 (950)
Depth mm 840 (950) 840 (950) 840 (950)
Weight (with Decoration Panel) kg 18 (23.4) 19 (24.4) 19 (24.4)
Sound Pressure High / Low dBA 31 / 27 31 / 27 33 / 28
Sound Power dBA 49 49 51
Outdoor Units RXS35K RXS50K RXS60F
Dimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
Weight kg 34 47 48
Electrical Details Power Supply 1ph
Running Current A 4.18* 6.48* 8.62*
Starting Current A 4.30 6.80 9.40
Max Fuse Size A 10 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2
Pipework Maximum Length m 20 30 30
Maximum Vertical Rise m 15 20 20
Precharged to m 10 10 10
Additional Charge g/m 20.0 20.0 20.0
Holding Charge kg 1.2 1.7 1.5
Sound Pressure High dBA 48 48 49
Sound Power dBA 48 48 49
Trade Fan Coil Price 703.00 720.00 766.00
Trade Condensing Unit Price 541.00 680.00 725.00
Total System Price 1,244.00 1,400.00 1,491.00
Features:
FCQG is a compact cassette designed to suit installation in narrower ceiling voids
The unique 360 radial air pattern ensures uniform air fow and temperature distribution
Air fow fexibility: a wide selection of 23 diferent air fow patterns accessible via remote controller
Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels
Optional Self Cleaning Filter: The BYCQ140DG decoration panel can ofer energy savings, reduced maintenance time and cost
Suitable for Twin, Triple and Double Twin applications
Re-use of existing R22 and R407C piping possible
DIII net compatibility as standard
Accessories: Notes:
i) BRC7FA532F Trade price will be reduced
by 74.00 if ordered at the same time as
the fan coil unit in place of the BRC1E52A
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iv) All fan coils supplied as standard with
BYCQ140D Decoration panel
v) BYCQ140DW / BYCQ140DG Trade prices
will be reduced by 139.00 if ordered at
the same time as a fan coil in place of
standard decoration panel
vi) Data marked with * is preliminary
vii) Minimum ambient operating
temperatures:
Cooling Heating
RZQG -15C -20C
RZQSG -5C -15C
RXS -10C -15C
Accessory Ref Description Trade Price
BRC7FA532F Wireless remote controller 149.00
BYCQ140DG Roundfow cassette decoration panel with self cleaning flter 303.00
BYCQ140DW Roundfow cassette decoration panel - white with white louvres 156.00
BRYQ140A Integral PIR Sensor for Roundfow decoration panel. Enables Energy Saving functions 97.00
KDBHQ55B140 Sealing member for air discharge outlet 88.00
KDDQ55B140 1/2 Fresh air intake kit for up to 20% fresh air (not compatible with self cleaning deco-panel) 440.00
KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 89.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
KRCS01-4 Remote room mounted temperature sensor 46.00
K.RSS Wireless room mounted temperature sensor and receiver 91.00
RS-SE Service and Confguration Tool for K.RSS 87.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
Price List 2013 29
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Under Ceiling Cassette
Seasonal Smart Inverter FUQ-C / RZQG
Indoor Units Single Phase 3 Phase
FUQ71C FUQ100C FUQ125C FUQ71C FUQ100C FUQ125C
Capacity UK Total Cooling kW 7.76 10.80 13.60 7.76 10.80 13.60
UK Sensible Cooling kW 5.32 7.44 9.30 5.32 7.44 9.30
Nominal Cooling kW 6.80 9.50 12.00 6.80 9.50 12.00
Nominal Heating kW 7.50 10.80 13.50 7.50 10.80 13.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A++ A+ A++ A++ A+
Pdesign kW 6.80 9.50 12.00 6.80 9.50 12.00
SEER 6.50 6.11 5.61 6.50 6.11 5.61
Annual Energy Consumption kWh 367 545 749 367 545 749
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A+ A+ A+ A+ A+
Pdesign kW 7.60 11.30 14.13 7.60 11.30 14.13
SCOP 4.20 4.50 4.44 4.20 4.50 4.44
Annual Energy Consumption kWh 2533 3517 4456 2533 3517 4456
Nominal Efciency EER / COP 4.07 / 4.47 4.08 / 4.04 3.4 / 4.04 4.07 / 4.47 4.08 / 4.04 3.4 / 4.04
Energy Label A / A A / A A / A A / A A / A A / A
Annual Energy Consumption kWh 840 1230 1770 840 1230 1770
Air Flow Rate High / Low m
3
/min 23 / 16 31 / 20 32.5 / 20.5 23 / 16 31 / 20 32.5 / 20.5
Dimensions Height mm 198 198 198 198 198 198
Width mm 950 950 950 950 950 950
Depth mm 950 950 950 950 950 950
Weight kg 25 26 26 25 26 26
Sound Pressure High / Low dBA 41 / 35 46 / 39 47 / 40 41 / 35 46 / 39 47 / 40
Sound Power dBA 59 64 65 59 64 65
Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1
Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 78 102 80 101
Electrical Details Power Supply 1ph 3ph
Running Current A 7.72 10.78 15.91 2.57 3.58 5.29
Starting Current A 4 4 4 4 4 4
Max Fuse Size A 20 32 32 16 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 50 75 75 50 75 75
Maximum Vertical Rise m 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.9 4.0 4.0 2.9 4.0 4.0
Sound Pressure High dBA 48 50 51 48 50 51
Sound Power dBA 48 50 51 48 50 51
Trade Fan Coil Price 897.00 984.00 1,087.00 897.00 984.00 1,087.00
Trade Condensing Unit Price 1,168.00 1,484.00 1,633.00 1,203.00 1,553.00 1,709.00
Total System Price 2,065.00 2,468.00 2,720.00 2,100.00 2,537.00 2,796.00
Features:
The 4-way blow ceiling suspended cassettes are the ideal solution for rooms, shops or ofces without false ceilings
Seasonally Efcient Inverter Technology gives up to 25% better efciency than inverter technology
Air fow fexibility: air can be discharged in any of 4 directions. Possibility to shut of 1 or 2 faps enabling the unit to be installed in a corner or small room
3 step fan-speed
Suitable for Twin, Triple and Double Twin applications
Re-use of existing R22 and R407C piping possible
Comms, computer and server room cooling possible with EDP setting
Selectable evaporating & condensing temperature for greater operating efciency
Accessory Ref Description Trade Price
BRC7C58 Wireless remote controller 149.00
EKRORO5 Remote on/of control interface kit 28.00
KRP4A53/UK.FB2 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 89.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
KRCS01-1 Remote room mounted temperature sensor 45.00
K.RSS Wireless room mounted temperature sensor and receiver 91.00
RS-SE Service and Confguration Tool for K.RSS 87.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
Accessories: Notes:
i) BRC7C58 Trade price will be reduced by
74.00 if ordered at the same time as the
fan coil unit in place of the BRC1E52A
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iv) Minimum ambient operating
temperatures:
Cooling Heating
RZQG -15C -20C
Integrated Solutions 30
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Built in DC Ducted
Seasonal Smart Inverter FBQ / RZQG
Indoor Units Single Phase 3 Phase
FBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8 FBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8
Capacity UK Total Cooling kW 7.76 10.80 13.60 14.90 7.76 10.80 13.60 14.90
UK Sensible Cooling kW 5.32 7.44 9.30 10.25 5.32 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 6.80 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 7.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A++ A+ A+ - A++ A+ A+ -
Pdesign kW 6.80 9.50 12.00 - 6.80 9.50 12.00 -
SEER 6.11 5.80 5.81 - 6.11 5.80 5.81 -
Annual Energy Consumption kWh 390 574 723 - 390 574 723 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A++ A+ - A+ A++ A+ -
Pdesign kW 6.00 11.30 12.71 - 6.00 11.30 12.71 -
SCOP 4.01 4.61 4.21 - 4.01 4.61 4.21 -
Annual Energy Consumption kWh 2096 3433 4226 - 2096 3433 4226 -
Nominal Efciency EER / COP 3.5 / 3.65 3.89 / 4.21 3.81 / 3.83 3.33 / 3.61 3.5 / 3.65 3.89 / 4.21 3.81 / 3.83 3.33 / 3.61
Energy Label A / A A / A A / A A / A A / A A / A A / A A / A
Annual Energy Consumption kWh 970 1220 1575 2010 970 1220 1575 2010
Air Flow Rate High / Low m
3
/min 18 / 15 32 / 23 39 / 28 39 / 28 18 / 15 32 / 23 39 / 28 39 / 28
Dimensions Height mm 300 300 300 300 300 300 300 300
Width mm 1000 1400 1400 1400 1000 1400 1400 1400
Depth mm 700 700 700 700 700 700 700 700
Weight kg 38 45 45 45 38 45 45 45
Sound Pressure High / Low dBA 37 / 29 38 / 32 40 / 33 40 / 33 37 / 29 38 / 32 40 / 33 40 / 33
Sound Power dBA 57 61 66 66 57 61 66 66
Outdoor Units RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Dimensions Height x Width x Depth mm 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 78 102 80 101
Electrical Details Power Supply 1ph 3ph
Running Current A 8.97 11.29 14.57 18.59 2.98 3.75 4.84 6.18
Starting Current A 4 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 16 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 50 75 75 75 50 75 75 75
Maximum Vertical Rise m 30 30 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0
Sound Pressure High dBA 48 50 51 52 48 50 51 52
Sound Power dBA 48 50 51 52 48 50 51 52
Trade Fan Coil Price 899.00 941.00 1,114.00 1,292.00 899.00 941.00 1,114.00 1,292.00
Trade Condensing Unit Price 1,168.00 1,484.00 1,633.00 1,864.00 1,203.00 1,553.00 1,709.00 1,963.00
Total System Price 2,067.00 2,425.00 2,747.00 3,156.00 2,102.00 2,494.00 2,823.00 3,255.00
Features:
The new inverter fan ducted units, provides both drastic energy savings and simplies installation
Automatically adjusts air volume against ESP at commissioning
Seasonally Ecient Inverter Technology gives up to 25% better eciency than inverter technology
Comms, computer and server room cooling possible with EDP setting
Selectable evaporating & condensing temperature for greater operating efciency
Accessory Ref Description Applicable Units Trade Price
BRC4C65 Wireless remote controller 149.00
EKRORO3 Remote on/of control interface kit 28.00
KRP4A53 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 65.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
KRCS01-4 Remote room mounted temperature sensor 46.00
K.RSS Wireless room mounted temperature sensor and receiver 91.00
RS-SE Service and Confguration Tool for K.RSS 87.00
BYBS71D Return air suction grille FBQ71 155.00
BYBS125D Return air suction grille FBQ100~140 194.00
EKBYBSD Mounting Kit for Decoration Panel (when installed directly onto the unit body) 27.00
UK.RAC3 Return Air Chamber, 2no 200mm dia FBQ71 84.00
UK.RAC3A Return Air Chamber, 3no 200mm dia FBQ71 91.00
UK.RAC4 Return Air Chamber, 4no 200mm dia FBQ100~140 113.00
UK.SAF3 Supply Air Flange 2x 200dia FBQ71 77.00
UK.SAF3A Supply Air Flange 3x 200dia FBQ71 82.00
UK.SAF4 Supply Air Flange 4x 200dia FBQ100~140 101.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
Accessories: Notes:
i) BRC4C65 Trade price will be reduced by
74.00 if ordered at the same time as the
fan coil unit in place of the BRC1E52A
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iv) All fan coils supplied as standard with
air flter
v) Minimum ambient operating
temperatures:
Cooling Heating
RZQG -15C -20C
RZQSG -5C -15C
Fan speed: 2 fan speeds can be selected, high or low
Suitable for Twin, Triple and Double Twin applications
Re-use of existing R22 and R407C piping possible
DIII net compatibility as standard
Price List 2013 31
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Built in DC Ducted
Seasonal Classic Inverter FBQ / RZQSG
Indoor Units Single Phase 3 Phase
FBQ71C8 FBQ100C8 FBQ125C8 FBQ140C8 FBQ100C8 FBQ125C8 FBQ140C8
Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90
UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25
Nominal Cooling kW 6.80 9.50 12.00 13.40 9.50 12.00 13.40
Nominal Heating kW 7.50 10.80 13.50 15.50 10.80 13.50 15.50
Seasonal Efciency
(EN14825)
COOLING
Energy Label A+ A A - A A -
Pdesign kW 6.80 9.50 12.00 - 9.50 12.00 -
SEER 5.81 5.50 5.20 - 5.50 5.20 -
Annual Energy Consumption kWh 410 605 808 - 6 5 -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A A+ A - 605.00 808.00 -
Pdesign kW 6.00 7.60 7.60 - 4.01 3.90 -
SCOP 3.88 4.01 3.90 - A A -
Annual Energy Consumption kWh 2156 2553 2727 - A+ A -
Nominal Efciency EER / COP 3.28 / 3.61 3.31 / 3.65 3.21 / 3.51 3.02 / 3.41 3.31 / 3.65 3.21 / 3.51 3.02 / 3.41
Energy Label A / A A / A A / B B / B A / A A / B B / B
Annual Energy Consumption kWh 1037 1435 1870 2220 1435 1870 2220
Air Flow Rate High / Low m
3
/min 18 / 15 32 / 23 39 / 28 39 / 28 32 / 23 39 / 28 39 / 28
Dimensions Height mm 300 300 300 300 300 300 300
Width mm 1000 1400 1400 1400 1400 1400 1400
Depth mm 700 700 700 700 700 700 700
Weight kg 38 45 45 45 45 45 45
Sound Pressure High / Low dBA 37 / 29 38 / 32 40 / 33 40 / 33 38 / 32 40 / 33 40 / 33
Sound Power dBA 57 61 66 66 61 66 66
Outdoor Units RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 67 81 102 82 101
Electrical Details Power Supply 1ph 3ph
Running Current A 9.00 12.48 16.26 19.30 4.39 5.72 6.79
Starting Current A 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 30 50 50 50 50 50 50
Maximum Vertical Rise m 15 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0
Sound Pressure High dBA 49 53 54 53 53 54 53
Sound Power dBA 49 53 54 53 53 54 53
Trade Fan Coil Price 899.00 941.00 1,114.00 1,292.00 941.00 1,114.00 1,292.00
Trade Condensing Unit Price 864.00 1,196.00 1,312.00 1,461.00 1,232.00 1,351.00 1,505.00
Total System Price 1,763.00 2,137.00 2,426.00 2,753.00 2,173.00 2,465.00 2,797.00
Integrated Solutions 32
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Built in DC Ducted & Slim Ducted
Inverter FBQ & FDXS-F / RXS
Indoor Units DC Ducted Slim Ducted
FBQ35C8 FBQ50C8 FBQ60C8 FDXS25F FDXS35F FDXS50F FDXS60F
Capacity UK Total Cooling kW 3.32 4.89 5.60 2.35 3.32 4.81 5.86
UK Sensible Cooling kW 2.93 3.60 4.50 1.81 2.26 3.08 3.97
Nominal Cooling kW 3.40 5.00 5.70 2.40 3.40 5.00 6.00
Nominal Heating kW 4.00 6.00 7.00 3.20 4.00 5.80 7.00
Seasonal Efciency
(EN14825)
COOLING
Energy Label C B A B B A A
Pdesign kW 3.40 5.00 5.70 2.40 3.40 5.00 6.00
SEER 4.33 4.96 5.17 5.08 4.82 5.12 5.50
Annual Energy Consumption kWh 283 346 406 165 247 342 382
Seasonal Efciency
(EN14825)
HEATING
Energy Label A A A A+ A A A
Pdesign kW 3.50 4.90 4.80 2.60 2.90 3.50 4.00
SCOP 3.56 3.53 3.43 4.19 3.81 3.41 3.51
Annual Energy Consumption kWh 1141 1782 1960 869 1066 1438 1596
Nominal Efciency EER / COP 3.21 / 3.51 3.03 / 3.42 3.26 / 3.41 3.72 / 3.9 3.21 / 3.39 3.03 / 3.1 2.91 / 3.21
Energy Label A / B B / B A / B A / A A / B B / D C / C
Annual Energy Consumption kWh 530 825 875 323 530 825 1030
Air Flow Rate High / Low m
3
/min 16 / 11 16 / 11 18 / 15 8.7 / 7.3 8.7 / 7.3 12 / 10 16 / 13.5
Dimensions Height mm 300 300 300 200 200 200 200
Width mm 700 700 1000 750 750 950 1150
Depth mm 700 700 700 620 620 620 620
Weight kg 27 28 38 21 21 27 30
Sound Pressure High / Low dBA 32 / 27 37 / 29 37 / 30 35 / 27 35 / 27 37 / 29 38 / 30
Sound Power dBA 50 55 55 53 53 55 56
Outdoor Units RXS35K RXS50K RXS60F RXS25K RXS35K RXS50K RXS60F
Dimensions Height x Width x Depth mm 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
Weight kg 34 47 48 34 34 47 48
Electrical Details Power Supply 1ph - see notes 1ph 1ph
Running Current A 5.03* 8.38* 10.1* 3.90 4.90 7.10 9.20
Starting Current A 4.3 6.8 9.4 3.3 4.3 6.8 9.4
Max Fuse Size A 10 20 20 10 10 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 1/4 / 1/2
Pipework Maximum Length m 20 30 30 20 20 30 30
Maximum Vertical Rise m 15 20 20 15 15 20 20
Precharged to m 10 10 10 10 10 10 10
Additional Charge g/m 20.0 20.0
Holding Charge kg 1.2 1.7 1.5 1.0 1.2 1.7 1.5
Sound Pressure High dBA 48 48 49 46 48 48 49
Sound Power dBA 48 48 49 46 48 48 49
Trade Fan Coil Price 536.00 563.00 626.00 386.00 432.00 467.00 513.00
Trade Condensing Unit Price 541.00 680.00 725.00 467.00 541.00 680.00 725.00
Total System Price 1,077.00 1,243.00 1,351.00 853.00 973.00 1,147.00 1,238.00
Accessory Ref Description Applicable Units Trade Price
BRC4C65 Wireless remote controller FBQ / FDXS 149.00
BRC2C51 Simplifed remote control FDXS
EKRORO3 Remote on/of control interface kit FBQ 28.00
KRP4A53 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting FBQ 65.00
RTD-NET/UK.FP Modbus Interface PCB for Sky Air & VRV FBQ / FDXS 185.00
RTD-10/UK.FP Enhanced function PCB for Sky Air: Duty rotation, lead lag control & heating interlock FBQ / FDXS 229.00
RTD-20/UK.FP Energy Control for Sky Air FBQ / FDXS POA
KLIC-DI KNX Interface for Sky Air and VRV systems FBQ / FDXS 181.00
KRCS01-4 Remote room mounted temperature sensor FBQ / FDXS 46.00
K.RSS Wireless room mounted temperature sensor and receiver FBQ 91.00
RS-SE Service and Confguration Tool for K.RSS FBQ 87.00
BYBS45D Return air suction grille FBQ35~50 118.00
BYBS71D Return air suction grille FBQ60 155.00
UK.RAC2 Return Air Chamber, 2 x 200mm dia FBQ35~50 77.00
UK.RAC3 Return Air Chamber, 2 x 200mm dia FBQ60 84.00
UK.RAC3A Return Air Chamber, 3 x 200mm dia FBQ60 91.00
UK.RAC5 Return Air Chamber, 2 x 150mm dia FDXS25~35 POA
UK.RAC6 Return Air Chamber, 3 x 150mm dia FDXS50 POA
UK.RAC7 Return Air Chamber, 4 x 150mm dia FDXS60~71 POA
UK.SAF2 Supply Air Flange 2 x 200mm dia FBQ35~50 70.00
UK.SAF3 Supply Air Flange 2 x 200mm dia FBQ60 77.00
UK.SAF3A Supply Air Flange 3 x 200mm dia FBQ60 82.00
UK.SAF5 Supply Air Flange 2 x 150mm dia FDXS25~35 65.00
UK.SAF6 Supply Air Flange 3 x 150mm dia FDXS50 71.00
UK.SAF7 Supply Air Flange 4 x 150mm dia FDXS60~71 83.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGS Condensing Unit Guard size 20-35 209.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories: Notes:
i) Data marked * is provisional
ii) BRC4C65 Trade price will be reduced by
74.00 if ordered at the same time as the
fan coil unit in place of the BRC1E52A
iii) All fan coil units standard with auto restart
after power failure
iv) FBQ and FDXS fan coils supplied as
standard with BRC1E52A wired remote
controller with 7-day time clock
v) All fan coils supplied as standard with
air flter
vi) Minimum ambient operating
temperatures:
vii) FBQ35C Fan Coil unit requires a separate
1ph 5 amp power supply
Cooling Heating
RZQG -15C -20C
RZQSG -5C -15C
RXS -10C -15C
Features:
Fan speed: 5 fan speeds can be selected, high to super low Connection to multi outdoor possible Re-use of existing R22 and R407C piping possible
Price List 2013 33
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
High Static Ducted Seasonal Smart,
Classic & Super Inverter FDQ
Indoor Units Single Phase 3 Phase Single Phase 3 Phase Super Inverter (3 phase)
FDQ125C FDQ125C FDQ125C FDQ125C FDQ200B FDQ250B
Capacity UK Total Cooling kW 13.60 13.60 13.60 13.60 19.40 23.50
UK Sensible Cooling kW 9.30 9.30 9.30 9.30 16.30 20.70
Nominal Cooling kW 12.00 12.00 12.00 12.00 20.00 25.00
Nominal Heating kW 13.50 13.50 13.50 13.50 23.00 27.00
Seasonal Efciency
(EN14825)
COOLING
Energy Label A A A A - -
Pdesign kW 12.00 12.00 12.00 12.00 - -
SEER 5.81 5.81 5.20 5.20 - -
Annual Energy Consumption kWh 723 723 806 806 - -
Seasonal Efciency
(EN14825)
HEATING
Energy Label A+ A+ A A - -
Pdesign kW 12.71 12.71 7.60 7.60 - -
SCOP 4.21 4.21 3.90 3.90 - -
Annual Energy Consumption kWh 4226 4226 2727 2727 - -
Nominal Efciency EER / COP 3.75 / 3.83 3.75 / 3.83 3.21 / 3.51 3.21 / 3.51 3.21 / 3.41 2.81 / 3.21
Energy Label A / A A / A A / B A / B A / B C / C
Annual Energy Consumption kWh 1600 1600 1870 1870 3115 4290
Air Flow Rate High / Low m
3
/min 39 / 28 39 / 28 39 / 28 39 / 28 69 / 69 89 / 89
Dimensions Height mm 300 300 300 300 450 450
Width mm 1400 1400 1400 1400 1400 1400
Depth mm 700 700 700 700 900 900
Weight kg 45 45 45 45 93 93
Sound Pressure High / Low dBA 40 / 33 40 / 33 40 / 33 40 / 33 45 / 45 47 / 47
Sound Power dBA 66 66 66 66 81 82
Outdoor Units RZQG125L8V1 RZQG125L8Y1 RZQSG125L8V1 RZQSG125L8Y1 RZQ200C RZQ250C
Dimensions Height x Width x Depth mm 1430 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 990 x 940 x 320 1680 x 930 x 765 1680 x 930 x 765
Weight kg 102 101 81 82 183 184
Electrical Details Power Supply 1ph - see notes 3ph - see notes 1ph - see notes 3ph - see notes 3ph - see notes
Running Current A 14.80 4.89 17.30 5.72 4.61 6.35
Starting Current A 4 4 4 4 4 4
Max Fuse Size A 32 20 32 20 25 25
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 7/8 1/2 / 7/8
Pipework Maximum Length m 75 75 50 50 100 100
Maximum Vertical Rise m 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 4.0 4.0 2.9 2.9 8.3 9.3
Sound Pressure High dBA 51 51 54 54 57 57
Sound Power dBA 51 51 54 54 57 57
Trade Fan Coil Price 1,219.00 1,219.00 1,219.00 1,219.00 1,530.00 1,874.00
Trade Condensing Unit Price 1,633.00 1,709.00 1,312.00 1,351.00 2,862.00 2,998.00
Total System Price 2,852.00 2,928.00 2,531.00 2,570.00 4,392.00 4,872.00
Features:
High static units for longer ducted runs
Up to 200Pa External Static Pressure
Auto balancing air fow / ESP on commissioning
Comms, computer and server room cooling possible (Seasonal Smart only)
Super inverter technology: reduces power consumption by up to 70% compared to non inverter units
Selectable evaporating & condensing temperature for greater operating efciency (Seasonal Smart only)
Accessory Ref Description Trade Price
EKRORO Remote on/of control interface kit 15.00
KRP4A53 Unit/Group adaptor PCB for remote on/of, status indication and temperature setting 65.00
RTD-NET/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-10/UK.FB2 Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock 229.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
KLIC-DI KNX Interface for Sky Air and VRV systems 181.00
DTA112B51 Adaptor PCB for interface to Daikin centralised control systems (FDQ250B and FDQ200B only) 87.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
Accessories:
Cooling Heating
RZQG -15C -20C
RZQSG -5C -15C
RZQ -5C -15C
Notes:
i) Replacement technology not applicable
to RZQ200 and RZQ250
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
iv) All fan coils supplied as standard with
air flter
v) Minimum ambient operating
temperatures:
vi) FDQ Fan Coil unit requires a separate
15 amp power supply
Integrated Solutions 34
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Multi Series Inverters ofer the ability to connect up to 5 fan coils to one
outdoor unit. With the MXS range it is possible to install indoor units throughout a house or
small commercial premises and only use 1 outdoor unit. Each indoor unit will have its own controller.
Multi Series
Heating & cooling
Connectable
Indoor Units
Wall mounted Floor standing Flexi type Round fow
cassette
Fully fat
cassette
Concealed ceiling Ceiling
suspended
FTXG-J CTXS-K FTXS-K FTXS-G FTX-JV FVXG-K FVXS-F FLXS-B FCQG-F FFQ-C FDXS-F FBQ-C8 FHQ-C
25 35 50 15 35 20 25 35 42 50 60 71 20 25 35 25 35 50 25 35 50 25 35 50 60 35 50 60 25 35 50 60 25 35 50 60 25 35 50 60 35 50 60
2MXS40H
2MXS50H
3MXS40K
3MXS52E
3MXS68G
4MXS68F
4MXS80E
5MXS90E
Outdoor Unit Indoor Unit
Cooling Mode Heating Mode
SEER Energy
efciency
class
Annual energy
consumption
kWh/a
Design load
PDesign kW
SCOP Energy
efciency
class
Annual
electricity
consumption
kWh/a
Design load
PDesign at
-10C kW
Declared
heating
capacity
at -10C
Back up
heating
capacity
2MXS40H3V1B 2 x FTXS20K2V1B 6.61 A++ 212 4.0 4.12 A+ 1029 3.1 2.5 0.6
2MXS50H3V1B 2 x FTXS25K2V1B 6.61 A++ 265 5.0 4.00 A+ 1466 4.2 3.4 0.8
3MXS40K3V1B 2 x FTXS20K2V1B 6.9 A++ 203 4.0 4.05 A+ 1641 4.8 3.9 0.9
3MXS52E4V1B 2 x CTXS15K2V1B,
1 x FTXS20K2V1B
7.15 A++ 245 5.0 4.31 A+ 1605 5.0 4.0 1.0
3MXS68G3V1B 1 x CTXS15K2V1B,
2 x FTXS20K2V1B
5.34 A 446 6.8 4.00 A+ 1868 5.4 4.4 1.0
4MXS68F3V1B 2 x CTXS15K2V1B,
2 x FTXS20K2V1B
5.68 A+ 420 6.8 4.15 A+ 1953 5.8 4.7 1.1
4MXS80E3V3B 3 x CTXS15K2V1B,
1 x FTXS35K2V1B
6.16 A++ 416 7.4 4.00 A+ 2194 6.3 5.1 1.2
5MXS90E3V3B 2 x CTXS15K2V1B,
3 x FTXS20K2V1B
6.42 A++ 424 7.8 4.19 A+ 2161 6.5 5.3 1.2
For seasonal data in combination with other indoor units, please consult www.daikineurope.com/energylabel
Emura Wall Mounted Fan Coil Units FTXG25JW FTXG35JW FTXG50JW FTXG25JA FTXG35JA FTXG50JA
Trade Fan Coil Unit Price 271.00 304.00 464.00 323.00 362.00 554.00
Wall Mounted Fan Coil Units CTXS15K FTXS20K FTXS25K FTXS35K FTXS42K FTXS50K FTXS60G FTXS71G
Trade Fan Coil Unit Price 143.00 151.00 162.00 185.00 208.00 288.00 294.00 392.00
Wall Mounted Low Inverter Fan Coil Units FTX20JV FTX25JV FTX35JV
Trade Fan Coil Unit Price 121.00 133.00 151.00
Flexi Fan Coil Units FLXS25B FLXS35B FLXS50B FLXS60B
Trade Fan Coil Unit Price 369.00 415.00 450.00 495.00
Nexura Floor Standing Fan Coil Units FVXG25K FVXG35K FVXG50K
Trade Fan Coil Unit Price 619.00 666.00 729.00
Floor Standing Fan Coil Units FVXS25F FVXS35F FVXS50F
Trade Fan Coil Unit Price 513.00 553.00 604.00
Compact Roundfow Cassette Fan Coil Units FCQG35F FCQG50F FCQG60F
Trade Fan Coil Unit Price 703.00 720.00 766.00
600 Sq 600 Sq 4-way blow Cassette Fan Coil Units FFQ25C FFQ35C FFQ50C FFQ60C
Trade Fan Coil Unit Price 649.00 712.00 786.00 832.00
Ceiling Suspended Fan Coil Units FHQ35C FHQ50C FHQ60C
Trade Fan Coil Unit Price 696.00 754.00 828.00
Ducted Fan Coil Units FDBQ25B FBQ35C8 FBQ50C8 FBQ60C8
Trade Fan Coil Unit Price 415.00 536.00 563.00 626.00
Slim Ducted Fan Coil Units FDXS25F FDXS35F FDXS50F FDXS60F
Trade Fan Coil Unit Price 386.00 432.00 467.00 513.00
Multi Split & Mini VRV Fan Coils
Notes:
i) Accessories for fan coils - refer to pair
system pages
ii) All fan coil units standard with auto restart
after power failure
iii) All fan coil units supplied as standard with
remote controller
iv) FDXS fan coil units supplied as standard
with air flter
v) 2MXS40-50H can only be used with
FTXG, FTXS, FTX, FDXS, FVXG, FVXS, FLXS
fan coil units
Price List 2013 35
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Multi Series Inverters
MXS-E/F/G/H/K
Outdoor Units 2MXS40H 2MXS50H 3MXS40K 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90E
Capacity Nominal Cooling kW 4.00 5.00 4.00 5.20 6.80 6.80 8.00 9.00
Nominal Heating kW 4.40 5.70 4.60 6.80 8.60 8.60 9.60 10.40
Dimensions Height mm 550 550 735 735 735 735 770 770
Width mm 765 765 936 936 936 936 900 900
Depth mm 285 285 300 300 300 300 320 320
Weight kg 38 42 49 49 58 58 72 73
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps Refer to Multi Combination Tables
Starting Current amps 4 4 4 4 4 4 4 4
Fuse Rating amps 16 16 16 20 20 20 20 20
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 1.2 1.6 2.0 2.0 2.6 2.6 3.0 3.0
Sound Pressure High dBA 47 48 46 47 48 49 49 52
Piping Limits Maximum Length m 30 30 50 50 60 60 70 75
Maximum Vertical Rise m 15 15 15 15 15 15 15 15
Piping Connections Liquid inches 2x 1/4 2x 1/4 3x 1/4 3x 1/4 3x 1/4 4x 1/4 4x 1/4 5x 1/4
Gas inches 2x 3/8 3/8 1/2 2x3/8 1/2 2x3/8 1/2 3/8 2x1/2 2x3/8 2x1/2 3/8 1/2 2x5/8 2x3/8 1/2 2x5/8
Number of Connected Indoor Units 2 2 3 3 3 4 4 5
Trade Condensing Unit Price 978.00 1,082.00 1,020.00 1,133.00 1,605.00 1,731.00 1,950.00 2,099.00
Notes:
i) Minimum ambient operating temperatures:
Cooling Heating
2MXS40, 50 10C -15C
3MXS40, 52, 68 -10C -15C
4MXS68, 80 -10C -15C
5MXS90 -10C -15C
Accessory Ref Description Trade Price
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.CGM Condensing Unit Guard size 42-71 290.00
Accessories:
Mini VRV for Residential Applications
RXYSQ-P8
Outdoor Units RXYSQ4P8V1 RXYSQ5P8V1 RXYSQ6P8V1
Capacity Nominal Cooling kW 12.60 14.00 15.50
Nominal Heating kW 14.20 16.00 18.00
Dimensions Height mm 1345 1345 1345
Width mm 900 900 900
Depth mm 320 320 320
Weight kg 120 120 120
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps Refer to Multi Combination Tables
Starting Current amps 4 4 4
Fuse Rating amps 32 32 32
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 4.0 4.0 4.0
Sound Pressure High dBA 50 51 53
Sound Power High dBA 66 67 69
Piping Limits Maximum Length m 115 135 145
Maximum Vertical Rise m data book data book data book
Piping Connections Liquid inches 3/8 3/8 3/8
Gas inches 5/8 5/8 3/4
Capacity Index Limit 50~130 62.5~162.5 70~182
Number of Connected Indoor Units 8 10 13
Trade Condensing Unit Price 2,681.00 3,014.00 3,364.00
Notes:
i) Minimum ambient operating temperatures:
Cooling Heating
RXYSQ-P8 -5C -20C
Please note: RXYSQ units are subject to VRV discount level
Accessory Ref Description Trade Price
BPMKS967A2 Branch Provider Kit - 2 fan coil units 349.00
BPMKS967A3 Branch Provider Kit - 3 fan coil units 372.00
KHRQ22M20T R410a 2 Pipe Refnet Joint 28.00
Accessories:
Integrated Solutions 36
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Wall Mounted Fan Coil Units FAQ71C FAQ100C
Trade Fan Coil Unit Price 783.00 846.00
Ceiling Suspended Fan Coil Units FHQ35C FHQ50C FHQ60C FHQ71C FHQ100C FHQ125C
Trade Fan Coil Unit Price 696.00 754.00 828.00 969.00 1,030.00 1,289.00
Compact Roundfow Cassette Fan Coil Units FCQG35F FCQG50F FCQG60F FCQG71F FCQG100F FCQG125F
Trade Fan Coil Unit Price 703.00 720.00 766.00 812.00 921.00 1,007.00
High COP Roundfow Cassette Fan Coil Units FCQHG71F FCQHG100FFCQHG125F
Trade Fan Coil Unit Price 812.00 921.00 1,007.00
600 Sq 4-way Blow Cassette Fan Coil Units FFQ35C FFQ50C FFQ60C
Trade Fan Coil Unit Price 712.00 786.00 832.00
Under Ceiling 4-way Blow Cassette Fan Coil Units FUQ71C FUQ100C FUQ125C
Trade Fan Coil Unit Price 897.00 984.00 1,087.00
DC Ducted Fan Coil Units FBQ35C8 FBQ50C8 FBQ60C8 FBQ71C8 FBQ100C8 FBQ125C8
Trade Fan Coil Unit Price 536.00 563.00 626.00 899.00 941.00 1,114.00
Slim Ducted Fan Coil Units FDXS35F FDXS50F FDXS60F
Trade Fan Coil Unit Price 432.00 467.00 513.00

High Static Ducted Fan Coil Units FDQ125C
Trade Fan Coil Unit Price 1,219.00
Twin, Triple and Double Twin Outdoor Units
Possible Combinations
Outdoor Units Nominal Cooling kW Nominal Heating kW Possible Combinations Model Types
RZQG71L8V1 / Y1 6.80 7.50 35 + 35 FFQ, FCQ, FBQ, FDXS, FHQ
RZQSG71L8V1 / Y1 6.80 7.50 35 + 35 FFQ, FCQ, FBQ, FDXS, FHQ
RZQG100L8V1 / Y1 9.50 10.80 50 + 50 FFQ, FCQ, FBQ, FDXS, FHQ
RZQG100L8V1 / Y1 9.50 10.80 35 + 35 + 35 FFQ, FCQ, FBQ, FDXS, FHQ
RZQSG100L8V1 / Y1 9.50 10.80 50 + 50 FFQ, FCQ, FBQ, FDXS, FHQ
RZQSG100L8V1 / Y1 9.50 10.80 35 + 35 + 35 FFQ, FCQ, FBQ, FDXS, FHQ
RZQG125L8V1 / Y1 12.00 13.50 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQ
RZQG125L8V1 / Y1 12.00 13.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQ
RZQG125L8V1 / Y1 12.00 13.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQ
RZQSG125L8V1 / Y1 12.00 13.50 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQ
RZQSG125L8V1 / Y1 12.00 13.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQ
RZQSG125L8V1 / Y1 12.00 13.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQ
RZQG140L7V1 / LY1 13.40 15.50 71 + 71 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ
RZQG140L7V1 / LY1 13.40 15.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQ
RZQG140L7V1 / LY1 13.40 15.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQ
RZQSG140LV1 / LY1 13.40 15.50 71 + 71 FCQG, FCQHG, FBQ, FHQ, FAQ
RZQSG140LV1 / LY1 13.40 15.50 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQ
RZQSG140LV1 / LY1 13.40 15.50 35 + 35 + 35 + 35 FFQ, FCQG, FBQ, FDXS, FHQ
RZQ200 19.50 23.40 100 + 100 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ
RZQ200 19.50 23.40 60 + 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQ
RZQ200 19.50 23.40 71 + 71 + 71 FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ
RZQ200 19.50 23.40 50 + 50 + 50 + 50 FFQ, FCQG, FBQ, FDXS, FHQ
RZQ250 25.00 27.00 125 + 125 FCQG, FCQHG, FBQ, FHQ, FUQ, FDQ
RZQ250 25.00 27.00 60 + 60 + 60 + 60 FFQ, FCQG, FBQ, FDXS, FHQ
Notes:
These systems allow a mixture of fan coil
types and sizes on the same condensing unit.
Each system is operated on the Master and
Slave principle from one remote controller.
As the number of possible combinations is so
great, we are unable to show each system as
separate prices within the price list.
To calculate a system price please refer to
the next pages for individual fan coil and
condensing unit prices and remember to add
the pipework joints listed as accessory items
on the following pages.
Each fan coil unit includes within its price for
a remote controller. As a complete system
requires only one controller, you will need to
subtract the controller cost from all but one
fan coil on each system.
EXAMPLE: TRADE EACH TRADE TOTAL
Heat pump triple system using the following:
3 No FCQG71-F Fan coil units 812.00 2,436.00
1 No RZQ200C Condensing unit 2,862.00 2,862.00
1 No KHRQ250H7 Pipework branch kit 79.00 79.00
2 No BRC1E52A Remote controller (Credit) -74.00 -148.00
TOTAL 5,229.00
Twin, Triple and Double Twin Outdoor Units
Fan Coils
Notes:
i) Each of the fan coil units includes one remote controller BRC1E52A
ii) FBQ50C to 71C fan coil units require a separate 1 ph power supply when connected to RZQ200 and 250C
iii) Self cleaning deco-panel BYCQ140DG is compatible on cassettes used in twin, triple and double twin applications
iv) For seasonal data on Twin, Triple and Double Twin applications please consult www.daikineurope.com/energylabel
v) Accessories for fan coils and condensing units - refer to pair system pages
Price List 2013 37
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Seasonal Smart Inverter
RZQG
Outdoor Units Seasonal Smart Inverter Seasonal Smart Inverter Super Inverter
Single Phase 3 Phase
RZQG
71L8V1
RZQG
100L8V1
RZQG
125L8V1
RZQG
140L7V1
RZQG-
71L8Y1
RZQG-
100L8Y1
RZQG-
125L8Y1
RZQG-
140LY1
RZQ200C RZQ250C
Dimensions Height mm 990 1430 1430 1430 990 1430 1430 1430 1680 1680
Width mm 940 940 940 940 940 940 940 940 930 930
Depth mm 320 320 320 320 320 320 320 320 765 765
Weight kg 78 102 102 102 80 101 101 101 183 184
Electrical Details Power Supply 1ph 3ph 3ph
Running Current A data book data book data book
Starting Current A 4 4 4 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 16 20 20 20 25 25
Interconnection Wiring Core / Cable size 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 7/8 1/2 / 7/8
Pipework Maximum Length m 50 75 75 75 50 75 75 75 100 100
Maximum Vertical Rise m 30
Precharged to m 30
Additional Charge g/m Refer to Installation Manual
Holding Charge kg 2.9 4.0 4.0 4.0 2.9 4.0 4.0 4.0 8.3 9.3
Sound Pressure High dBA 48 50 51 52 48 50 51 52 57 57
Trade Condensing Unit Price 1,168.00 1,484.00 1,633.00 1,864.00 1,203.00 1,553.00 1,709.00 1,963.00 2,862.00 2,998.00
Accessory Ref Description Trade Price
KHRQ22M20T R410a 2 Pipe Refnet Joint 28.00
KHRQ127H Triple Refnet Joint - RZQS71~140,RZQ100~140 63.00
KHRQ250H7 Triple Refnet Joint - RZQ200~250 79.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
Accessories: Notes:
i) Accessories for fan coils and condensing
units - refer to pair system pages
Seasonal Classic Inverter
RZQSG
Outdoor Units Seasonal Classic Inverter Seasonal Classic Inverter
Single Phase 3 Phase
RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Dimensions Height mm 770 990 990 1430 990 990 1430
Width mm 900 940 940 940 940 940 940
Depth mm 320 320 320 320 320 320 320
Weight kg 67 81 81 102 82 82 101
Electrical Details Power Supply 1ph 3ph
Running Current A data book data book
Starting Current A 4 4 4 4 4 4 4
Max Fuse Size A 20 32 32 32 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5
Piping Connections Liquid / Gas inches 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Pipework Maximum Length m 30 50 50 50 50 50 50
Maximum Vertical Rise m 15
Precharged to m 30
Additional Charge g/m Refer to Installation Manual
Holding Charge kg 2.75 2.9 2.9 4.0 2.9 2.9 4.0
Sound Pressure High dBA 49 53 54 53 53 54 53
Trade Condensing Unit Price 864.00 1,196.00 1,312.00 1,461.00 1,232.00 1,351.00 1,505.00
Accessory Ref Description Trade Price
KHRQ22M20T R410a 2 Pipe Refnet Joint 28.00
KHRQ127H Triple Refnet Joint - RZQS71~140,RZQ100~140 63.00
KHRQ250H7 Triple Refnet Joint - RZQ200~250 79.00
UK.CWB90-2 Condensing unit bracket - up to size 71 36.00
UK.CWB140-2 Condensing unit bracket - sizes 100 to 140 45.00
UK.DT1 Condensate drip tray for use with UK.CWB90-2 54.00
UK.DT2 Condensate drip tray for use with UK.CWB140-2 57.00
UK.CGM Condensing Unit Guard size 42-71 290.00
UK.CGL Condensing Unit Guard size 100-140 including RXYSQ 347.00
Accessories: Notes:
i) Accessories for fan coils and condensing
units - refer to pair system pages
Integrated Solutions 38
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
E
N
E
R
G
Y

S
A
V
IN
G
S
U
P
T
O

7
2
%
A
IR

S
E
P
A
R
A
T
IO
N

E
F
F
IC
IE
N
C
Y

U
P
T
O

8
5
%
P
A
Y
B
A
C
K
T
IM
E
L
E
S
S
T
H
A
N

1
.
5
Y
E
A
R
S
Air curtains for light commercial applications
Biddle Standard air curtains are the ideal solution
for retailers and consultants to combat the issue
of climate separation across their outlet or
oce doorway.
Using a combination of rectier technology, optimised air
velocity and temperature control they deliver greater comfort
to sta and customers alike, all year round, in all weathers.
In conjunction with Biddle, Daikin now oer the top air
curtain to the market, coupling the benets of the Biddle air
curtain technology with the benets of the Daikin heat pump
inverter technology.
Biddle Standard air curtains are connected to selected Daikin
ERQ heat pump inverter condensing units ofering:
Wide capacity range for maximum application potential plus
exible control options
R-410A refrigerant, single and 3 phase
Wide operation range: -5~46C in cooling and -20~15.5C in heating
Air Curtains
Small Air Curtains: Free Hanging, Cassette and Recessed
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessory Ref Description Trade Price
BRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock 74.00
KRCS01-1 Remote room mounted temperature sensor 45.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
Matching Air Cooled
Condensing Units
Single Phase Three Phase
ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1
Trade Unit Price 1,503.00 1,675.00 2,009.00 1,709.00 3,207.00 3,341.00
CYQS150DK80*BN
CYQS200DK100*BN
CYQS250DK140*BN
Accessories: Notes:
i) Please refer to page 40 for ERQ features
and specifcations
ii) To calculate the price for a complete
system, add together the prices of the
Air Curtain, ERQ condensing unit and
remote controller as below example:
1 No CYQS150DK80FBN 3,564.00
1 No ERQ100AV1 1,503.00
1 No BRC1E52A 74.00
TOTAL 5,141.00
BIDDLE STANDARD AIR CURTAIN - SMALL CYQS150DK80*BN CYQS200DK100*BN CYQS250DK140*BN
* = F * = C * = R * = F * = C * = R * = F * = C * = R
Heating Capacity speed 3 kW 9.00 11.60 16.20
Delta T Inlet = room temperature speed 3 k 15 15 16
Power Input (50Hz) Fan only / Heating kW 0.35 / 0.35 0.46 / 0.46 0.58 / 0.58
Maximum Door Width m 1.50 2.00 2.50
Mounting Height *2 Max / Min m 2.7/2.0 2.7/2.0 2.7/2.0
Dimensions Height mm 270 270 270 270 270 270 270 270 270
Width mm 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548
Depth mm 590 821 561 590 821 561 590 821 561
Weight kg 66 83 88 83 102 108 107 129 137
Casing Colour white RAL9010 white RAL9010 white RAL9010
Minimum requiring ceiling void mm 420 420 420
Fan - Air Flow Rate Heating speed 3 m
3
/sec 0.485 0.647 0.808
Sound Pressure Heating speed 3 dBA 49 50 51
Refrigerant Type R-410A R-410A R-410A
Piping Connections Liquid (OD) / Gas mm 9.52/16.0 9.52/16.0 9.52/19.0
Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50
Trade Unit Price 3,564.00 3,564.00 3,756.00 4,355.00 4,355.00 4,701.00 4,867.00 4,867.00 5,268.00
Price List 2013 39
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Medium Air Curtains: Free Hanging, Cassette and Recessed
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessory Ref Description Trade Price
BRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock 74.00
KRCS01-1 Remote room mounted temperature sensor 45.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
Single Phase Three Phase
ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1
Trade Unit Price 1,503.00 1,675.00 2,009.00 1,709.00 3,207.00 3,341.00
CYQM100DK80*BN
CYQM150DK80*BN
CYQM200DK100*BN
CYQM250DK140*BN
Accessories: Notes:
i) Please refer to page 40 for ERQ features
and specifcations
ii) To calculate the price for a complete
system, add together the prices of the
Air Curtain, ERQ condensing unit and
remote controller as below example:
1 No CYQM150DK80FBN 4,117.00
1 No ERQ125AV1 1,675.00
1 No BRC1E52A 74.00
TOTAL 5,866.00
BIDDLE STANDARD AIR CURTAIN - MEDIUM CYQM100DK80*BN CYQM150DK80*BN CYQM200DK100*BN CYQM250DK140*BN
* = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = R
Heating Capacity speed 3 kW 9.20 11.00 13.40 19.90
Delta T Inlet = room temperature speed 3 k 17 14 13 15
Power Input (50Hz) Fan only / Heating kW 0.37 / 0.37 0.56 / 0.56 0.75 / 0.75 0.94 / 0.94
Maximum Door Width m 1.00 1.50 2.00 2.50
Mounting Height *2 Max / Min m 3.2/2.3 3.2/2.3 3.2/2.3 3.2/2.3
Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270
Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548
Depth mm 590 821 561 590 821 561 590 821 561 590 821 561
Weight kg 57 68 66 73 88 93 94 111 117 108 136 144
Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010
Minimum requiring ceiling void mm 420 420 420 420
Fan - Air Flow Rate Heating speed 3 m
3
/sec 0.446 0.669 0.892 1.115
Sound Pressure Heating speed 3 dBA 50 51 53 54
Refrigerant Type R-410A R-410A R-410A R-410A
Piping Connections Liquid (OD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0
Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50
Trade Unit Price 3,455.00 3,455.00 3,566.00 4,117.00 4,117.00 4,307.00 5,155.00 5,155.00 5,520.00 5,902.00 5,902.00 6,295.00
Large Air Curtains: Free Hanging, Cassette and Recessed
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessory Ref Description Trade Price
BRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock 74.00
KRCS01-1 Remote room mounted temperature sensor 45.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV. POA
Single Phase Three Phase
ERQ100AV1 ERQ125AV1 ERQ140AV1 ERQ125AW1 ERQ200AW1 ERQ250AW1
Trade Unit Price 1,503.00 1,675.00 2,009.00 1,709.00 3,207.00 3,341.00
CYQL100DK125*BN
CYQL150DK200*BN
CYQL200DK250*BN
CYQL250DK250*BN
Accessories: Notes:
i) Please refer to page 40 for ERQ features
and specifcations
ii) To calculate the price for a complete
system, add together the prices of the
Air Curtain, ERQ condensing unit and
remote controller as below example:
1 No CYQL100DK125FBN 3,942.00
1 No ERQ125AV1 1,675.00
1 No BRC1E52A 74.00
TOTAL 5,691.00
BIDDLE STANDARD AIR CURTAIN - LARGE CYQL100DK125*BN CYQL150DK200*BN CYQL200DK250*BN CYQL250DK250*BN
* = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = R
Heating Capacity speed 3 kW 15.60 23.30 29.40 31.10
Delta T Inlet = room temperature speed 3 k 15 15 14 12
Power Input (50Hz) Fan only / Heating kW 0.75 / 0.75 1.13 / 1.13 1.50 / 1.50 1.88 / 1.88
Maximum Door Width m 1.00 1.50 2.00 2.50
Mounting Height *2 Max / Min m 3.7/2.5 3.7/2.5 3.7/2.5 3.7/2.5
Dimensions Height mm 370 370 370 370 370 370 370 370 370 370 370 370
Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548
Depth mm 774 1105 745 774 1105 745 774 1105 745 774 1105 745
Weight kg 76 81 83 100 118 141 126 151 155 157 190 196
Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010
Minimum requiring ceiling void mm 520 520 520 520
Fan - Air Flow Rate Heating speed 3 m
3
/sec 0.861 1.292 1.722 2.153
Sound Pressure Heating speed 3 dBA 53 54 56 57
Refrigerant Type R-410A R-410A R-410A R-410A
Piping Connections Liquid (OD) / Gas mm 9.52/16.0 9.52/19.0 9.52/22.0 9.52/22.0
Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50
Trade Unit Price 3,942.00 3,942.00 3,953.00 5,624.00 5,624.00 5,805.00 6,981.00 6,981.00 7,344.00 8,148.00 8,148.00 8,597.00
Integrated Solutions 40
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
For central ducted distribution systems Daikin have the solution for providing cooling and heating
of the air, enabling optimal comfort and eciency.
Even without the benet of individual room control, the system
can provide a exible energy saving answer over traditional
methods through the incorporation of inverter control and heat
pump technology.
The following pages include Packaged Heat Pump Rooftop
systems, with optional economisers, to heat pump condensing
units and connection kits for use with other manufacturers
heating and cooling coils.
Central Ducted Solutions
Outdoor unit Trade Unit Price Control box Expansion Valve Kit
control z control y control xl class 63 class 80 class 100 class 125 class 140 class 200 class 250
EKEQDCB EKEQFCB EKEQDCB/RTD EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250
Coil Volume dm3
min 1.66 2.09 2.65 3.31 4.13 4.63 6.61
max 2.08 2.64 3.30 4.12 4.62 6.60 8.25
1ph ERQ100AV1 1,503.00 P P P P P P P - - -
ERQ125AV1 1,675.00 P P P P P P P P - -
ERQ140AV1 2,009.00 P P P - P P P P - -
3ph ERQ125AW1 1,709.00 P P P P P P P P - -
ERQ200AW1 3,207.00 P P P - - P P P P P
ERQ250AW1 3,341.00 P P P - - - P P P P
Trade Acc. Price 335.00 357.00 556.00 95.00 101.00 76.00 88.00 99.00 117.00 129.00
Air Cooled Heat Pump Inverter
Condensing Unit Kit for DX Coil
P: Pair Combination depending on air handling units coils volume X: Possibility to connect Control xl includes UK.RTD-20
A new range of R410a inverter condensing units for
pair application with air handling units:
Inverter controlled heat pump units
Large capacity range (from 63 to 250 class)
Ventilation and air conditioning in 1 solution
EKEXV-kit & control boxes are designed for outdoor installation
and can be wall mounted
Per EKEXV-kit/control box, only 1 air handling unit coil can
be connected
Outdoor unit operation range: -5CDB ~ 43CDB
Flexible control possibilities:
Control xl:
Full external control from 3rd party temperature controller with volt
free remote enable contact and linear variable capacity control output
Control y:
External control from 3rd party temperature controller with volt free
remote enable contact. Fixed evaporating temperature selection,
range: +3C to +10C
Control z (BRC1D52 required):
Control via Daikin BRC1D52 remote controller and return air or remote
sensor (KRCS01-1 optional). A volt free remote enable contact is
required to conrm fan operation status. For re-circ applications only
Liquid pipe
Gas pipe
Liquid pipe
Gas pipe
EV kit
Air handling unit
Field supply
Control box F1,F2 communication
DDC control
(control x)
Price List 2013 41
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
Large Condensing Units ERAD-E
Features:
Large Condensing Unit (Standard Noise Level)
ERAD120E-SS ERAD140E-SS ERAD170E-SS ERAD200E-SS ERAD220E-SS ERAD250E-SS ERAD310E-SS ERAD370E-SS ERAD440E-SS ERAD490E-SS
Capacity Nominal Cooling kW 121 144 165 196 219 252 306 370 435 488
EER 2.89 2.82 2.87 3.01 2.97 3.29 3.3 3.03 2.96 3.03
Refrigerant R134a
Dimensions Length mm 2170 2170 3070 3070 3070 3070 3070 3070 3070 3070
Height mm 2.27 2.27 2.27 2.27 2.27 2.27 2220 2220 2220 2220
Width mm 1290 1290 1290 1290 1290 1290 2240 2240 2240 2240
Weight kg 1564 1587 1698 1739 1886 1928 2355 2559 2642 2677
Electrical Details Power Supply V 400
Hz 50
ph 3
Trade Unit Price POA POA POA POA POA POA POA POA POA POA
Large Condensing Unit (Low Noise Level)
ERAD120E-SL ERAD140E-SL ERAD160E-SL ERAD190E-SL ERAD210E-SL ERAD240E-SL ERAD300E-SL ERAD350E-SL ERAD410E-SL ERAD460E-SL
Capacity Nominal Cooling kW 116 137 159 187 209 243 295 352 409 462
EER 2.74 2.61 2.76 2.82 2.83 3.11 3.22 2.88 2.72 2.76
Refrigerant R134a
Dimensions Length mm 2170 2170 3070 3070 3070 3070 3070 3070 3070 3070
Height mm 2.27 2.27 2.27 2.27 2.27 2.27 2220 2220 2220 2220
Width mm 1290 1290 1290 1290 1290 1290 2240 2240 2240 2240
Weight kg 1712 1738 1851 1897 2046 2091 2534 2741 2834 2873
Electrical Details Power Supply V 400
Hz 50
ph 3
Trade Unit Price POA POA POA POA POA POA POA POA POA POA
ERAD-E are a range of cooling only R134a condensing units for pair
application with air handling units
Large capacity range 100 kW to 410 kW
Superior control logic using the new MicroTech III controller
Single circuit units
Screw compressor with capacity control down to 25%
Available in both standard and low noise confgurations
Please contact your sales ofce for further information on these products
Rooftop Packaged Unit Heat Pump UATYQ
Notes:
i) Minimum Ambient operating conditions ii) Supplied with remote controller as standard
iii) Economiser option is supplied as a kit for site assembly
iv) Low ambient kit for models UATYPC available on request
v) Please check stock & delivery period for all model sizes
vi) Standard delivery for all units does not include of-loading to kerbside
vii) UATYQ250/350 can be of-loaded by fork-lift if there is one at site
viii) All other units require crane or HIAB. Prices for HIAB available on request
Cooling Heating
UATYQ250~700 0C -15C
UATYPC10~12 20C -15C
UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1 UATYPC10AY1 UATYPC12AY1
Capacity Nominal Cooling kW 27.34 35.58 44.72 55.69 66.82 72.60 101.10 109.60
Nominal Heating kW 24.91 34.79 41.79 53.93 61.69 69.61 102.30 126.30
Dimensions Height mm 1150 1028 1130 1048 1302 1302 1974 1974
Width mm 1638 2209 2209 2209 2209 2209 2252 2252
Depth mm 2063 2113 2113 2670 2670 2670 3180 3180
Weight kg 490 660 690 780 830 970 1510 1600
Air Flow Rate Indoor m
3
/min 93 122 160 190 205 233 312 354
External Static Indoor Pa 147 147 147 206 206 206
Air Flow Rate Outdoor m
3
/min 0 0 0 0 0 0 0 0
Refrigerant R410a R407C
Sound Power Level Outdoor dBA 82 83 83 87 90 90 80 80
Drain size mm 25.4 (OD)
Electrical Details Power Supply V 400
Hz 50
Phase 3ph
Running Current A 20.5 26.4 33.1 39.4 41.6 46.5 74.2 82.9
Starting Current A 118 93 123 137 144 148 175 , 215 215x2
Max Fuse Size A 32 40 40 50 50 50 125 125
Trade Unit Price 4,928.00 5,131.00 8,443.00 9,290.00 9,990.00 10,690.00 14,274.00 15,506.00
Economiser ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1
Trade Unit Price 868.00 912.00 956.00 1,003.00 1,054.00 1,106.00
Integrated Solutions 42
S
p
l
i
t
,

S
k
y

A
i
r

H
e
a
t

P
u
m
p
s
43
V
R
V

Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
VRV
Indoor Units 44
VRV Fan Coil Units 44
Air Curtains 52
Hot Water Connection 54

Outdoor Condensing Units 57
VRV Condensing Units Heat Pump Mini 57
VRV Condensing Units Heat Pump 58
VRV Condensing Units Heat Recovery 62
VRV Condensing Units Heat Recovery Hot Water 66
VRV Condensing Units Water Cooled 66
VRV Condensing Units Geothermal 67
VRV Condensing Units Replacement VRV-Q 68

Accessories 77
VRV Unit Accessories
Intelligent Controls
Integrated Solutions
V
R
V

44
VRV Fan Coil Roundfow Cassette
FXFQ-A
Notes:
i) Cassette prices include standard decoration panel - self cleaning panel available as an accessory item
ii) For accessories please refer to pages 77 - 84
Indoor Units FXFQ20A FXFQ25A FXFQ32A FXFQ40A FXFQ50A FXFQ63A FXFQ80A FXFQ100A FXFQ125A
Capacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70 7.20 9.00 11.30
UK Sensible Cooling kW 1.60 2.03 2.53 2.90 3.47 4.47 5.83 6.77 8.37
UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10 7.63 9.53 12.20
UK Heating VRVIII HR only kW 2.05 2.62 3.28 4.10 5.16 6.56 8.20 10.25 13.12
Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00
Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00 10.00 12.50 16.00
Air Flow Rate High m
3
/sec 0.21 0.21 0.21 0.23 0.25 0.28 0.38 0.44 0.55
Low m
3
/sec 0.15 0.15 0.15 0.16 0.18 0.18 0.21 0.21 0.33
Dimensions
(with Decoration Panel)
Height mm 204 (264) 204 (264) 204 (264) 204 (264) 204 (264) 204 (264) 246 (306) 246 (306) 288 (348)
Width mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Depth mm 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950) 840 (950)
Weight (with Decoration Panel) kg 19 (24.4) 19 (24.4) 19 (24.4) 20 (25.4) 21 (26.4) 21 (26.4) 24 (29.4) 24 (29.4) 26 (31.4)
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.3 0.3 0.3 0.3 0.4 0.4 0.6 0.8 1.3
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 31.0 31.0 31.0 33.0 33.0 35.0 38.0 43.0 45.0
Low dBA 28.0 28.0 28.0 29.0 29.0 30.0 30.0 30.0 36.0
Sound Power dBA 49 49 49 51 51 53 55 60 61
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 3/8 3/8 3/8 3/8
Gas inches 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8
Trade Unit Price 744.00 759.00 776.00 838.00 879.00 927.00 989.00 1,073.00 1,338.00
Indoor Units FXZQ15A FXZQ20A FXZQ25A FXZQ32A FXZQ40A FXZQ50A
Capacity UK Total Cooling kW TBC 1.80 2.30 2.90 3.60 4.50
UK Sensible Cooling kW TBC 1.43 1.70 2.03 2.77 3.43
UK Heating kW 1.45 1.91 2.44 3.05 3.81 4.80
UK Heating VRVIII HR only kW 1.56 2.05 2.62 3.28 4.10 5.16
Nominal Cooling kW 1.70 2.20 2.80 3.60 4.50 5.60
Nominal Heating kW 1.90 2.50 3.20 4.00 5.00 6.30
Air Flow Rate High m
3
/sec 0.14 0.15 0.15 0.17 0.19 0.24
Low m
3
/sec 0.11 0.11 0.11 0.12 0.13 0.17
Dimensions (with Decoration Panel) HxWxD mm 260 (306) x 575 (620) x 575 (620)
Weight (with Decoration Panel) kg 17.5 (20.2) 17.5 (20.2) 17.5 (20.2) 18 (20.7) 18 (20.7) 18 (20.7)
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.6 0.6 0.6 0.6 0.6 0.7
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 31.5 32.0 33.0 33.5 37.0 43.0
Low dBA 25.5 25.5 25.5 26.0 28.0 33.0
Sound Power dBA 49 49 50 51 54 60
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 1/4
Gas inches 1/2 1/2 1/2 1/2 1/2 1/2
Trade Unit Price 707.00 722.00 737.00 754.00 809.00 888.00
VRV Fan Coil 600 Sq 4 Way Blow Cassette
FXZQ-A
(FXZQ-A Series coming summer 2013. FXZQ-M9 series available until release)
Notes:
i) Cassette prices include Fully Flat decoration panel in fresh white. Other colour panels available on request.
ii) For accessories please refer to pages 77 - 84
Price List 2013 45
V
R
V

Indoor Units FXCQ20A FXCQ25A FXCQ32A FXCQ40A FXCQ50A FXCQ63A FXCQ80A FXCQ125A
Capacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70 TBC TBC
UK Sensible Cooling kW 1.47 1.83 2.23 2.70 3.30 4.07 TBC TBC
UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10 7.63 12.20
UK Heating VRVIII HR only kW 2.05 2.62 3.28 4.10 5.16 6.56 8.20 13.12
Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 14.00
Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00 10.00 16.00
Air Flow Rate High m
3
/sec 0.18 0.19 0.19 0.20 0.25 0.27 0.43 0.53
Low m
3
/sec 0.13 0.13 0.13 0.14 0.18 0.19 0.31 0.38
Dimensions
(with Decoration Panel)
Height mm 305 (360) 305 (360) 305 (360) 305 (360) 305 (360) 305 (360) 305 (360) 305 (360)
Width mm 775 (1070) 775 (1070) 775 (1070) 775 (1070) 990 (1285) 990 (1285) 1445 (1740) 1445 (1740)
Depth mm 620 (700) 620 (700) 620 (700) 620 (700) 620 (700) 620 (700) 620 (700) 620 (700)
Weight (with Decoration Panel) kg 19 (29) 19 (29) 19 (29) 19 (29) 22 (33) 25 (36) 33 (44) 38 (51)
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.9
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 32.0 34.0 34.0 36.0 37.0 39.0 42.0 46.0
Low dBA 28.0 29.0 30.0 31.0 31.0 32.0 33.0 38.0
Sound Power dBA tbc tbc tbc tbc tbc tbc tbc tbc
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 3/8 3/8 3/8
Gas inches 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8
Trade Unit Price 837.00 852.00 861.00 951.00 1,040.00 1,080.00 1,239.00 1,487.00
VRV Fan Coil 2 Way Blow Cassette
FXCQ-A
Notes:
i) Cassette prices include decoration panel
ii) For accessories please refer to pages 77 - 84
Indoor Units FXKQ25MA FXKQ32MA FXKQ40MA FXKQ63MA
Capacity UK Total Cooling kW 2.30 2.90 3.60 5.70
UK Sensible Cooling kW 2.10 2.40 2.73 4.33
UK Heating kW 2.44 3.05 3.81 6.10
UK Heating VRVIII HR only kW 2.62 3.28 4.10 6.56
Nominal Cooling kW 2.80 3.60 4.50 7.10
Nominal Heating kW 3.20 4.00 5.00 8.00
Air Flow Rate High m
3
/sec 0.18 0.18 0.22 0.30
Low m
3
/sec 0.15 0.15 0.17 0.25
Dimensions
(with Decoration Panel)
Height mm 215 (285) 215 (285) 215 (285) 215 (285)
Width mm 1110 (1240) 1110 (1240) 1110 (1240) 1310 (1440)
Depth mm 710 (800) 710 (800) 710 (800) 710 (800)
Weight (with Decoration Panel) kg 31 (39.5) 31 (39.5) 31 (39.5) 34 (43.5)
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.2 0.2 0.2 0.4
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 38.0 38.0 40.0 42.0
Low dBA 33.0 33.0 34.0 37.0
Sound Power dBA - - - -
Piping Connections Liquid inches 1/4 1/4 1/4 3/8
Gas inches 1/2 1/2 1/2 5/8
Trade Unit Price 927.00 937.00 1,024.00 1,139.00
VRV Fan Coil 1 Way Blow Corner Cassette
FXKQ-MA
Notes:
i) Cassette prices include decoration panel
ii) For accessories please refer to pages 77 - 84
Integrated Solutions
V
R
V

46
Indoor Units FXHQ32A FXHQ63A FXHQ100A
Capacity UK Total Cooling kW 2.90 5.70 9.00
UK Sensible Cooling kW 2.50 4.43 6.67
UK Heating kW 3.05 6.10 9.53
UK Heating VRVIII HR only kW 3.28 6.56 10.25
Nominal Cooling kW 3.60 7.10 11.20
Nominal Heating kW 4.00 8.00 12.50
Air Flow Rate High m
3
/sec 0.23 0.33 0.49
Low m
3
/sec 0.17 0.23 0.32
Dimensions Height x width x Depth mm 235 x 960 x 690 235 x 1270 x 690 235 x 1590 x 690
Weight kg 24 33 39
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.6 0.6 1.3
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 36.0 37.0 44.0
Low dBA 31.0 34.0 34.0
Sound Power dBA - - -
Piping Connections Liquid inches 1/4 3/8 3/8
Gas inches 1/2 5/8 5/8
Trade Unit Price 888.00 984.00 1,222.00
VRV Fan Coil Ceiling Suspended
FXHQ-A
Notes:
i) For accessories please refer to pages 77 - 84
Indoor Units FXUQ71A FXUQ100A
Capacity UK Total Cooling kW 6.40 9.00
UK Sensible Cooling kW 5.20 7.10
UK Heating kW 6.86 9.53
UK Heating VRVIII HR only kW 7.38 10.25
Nominal Cooling kW 8.00 11.20
Nominal Heating kW 9.00 12.50
Air Flow Rate High m
3
/sec 0.38 0.52
Low m
3
/sec 0.27 0.35
Dimensions Height mm 198 198
Width mm 950 950
Depth mm 950 950
Weight kg 26 27
Electrical Details Power Supply Phase 1 ph
Hz 50
V 230
Running Current amps 0.5 1.1
Fuse Rating amps 5.00
Sound Level Sound Pressure High dBA 40.0 47.0
Low dBA 36.0 40.0
Sound Power dBA tbc tbc
Piping Connections Liquid inches 3/8 3/8
Gas inches 5/8 5/8
Trade Unit Price 1,229.00 1,311.00
VRV Fan Coil Under Ceiling Cassette
FXUQ-A
Notes:
i) For accessories please refer to pages 77 - 84
Price List 2013 47
V
R
V

Indoor Units FXDQ20M9 FXDQ25M9


Capacity UK Total Cooling kW 1.80 2.30
UK Sensible Cooling kW 1.60 1.90
UK Heating kW 1.91 2.44
UK Heating VRVIII HR only kW 2.05 2.62
Nominal Cooling kW 2.20 2.80
Nominal Heating kW 2.50 3.20
Air Flow Rate High m
3
/sec 0.11 0.12
Low m
3
/sec 0.09 0.10
Dimensions Height x Width x Depth mm 230 x 652 x 502
Weight kg 17 17
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.1 0.1
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 37.0 37.0
Low dBA 32.0 32.0
Sound Power dBA 50 50
Piping Connections Liquid inches 1/4 1/4
Gas inches 1/2 1/2
Trade Unit Price 568.00 585.00
VRV Fan Coil Small Ducted
FXDQ-M9
Notes:
i) For accessories please refer to pages 77 - 84
ii) Fan coils supplied as standard with factory ftted flter
Indoor Units FXDQ15A FXDQ20A FXDQ25A FXDQ32A FXDQ40A FXDQ50A FXDQ63A
Capacity UK Total Cooling kW TBC 1.80 2.30 2.90 3.60 4.50 5.70
UK Sensible Cooling kW TBC 1.60 1.90 2.30 2.80 3.50 4.30
UK Heating kW 1.30 1.91 2.44 3.05 3.81 4.80 6.10
UK Heating VRVIII HR only kW 1.39 2.05 2.62 3.28 4.10 5.16 6.56
Nominal Cooling kW 1.70 2.20 2.80 3.60 4.50 5.60 7.10
Nominal Heating kW 1.70 2.50 3.20 4.00 5.00 6.30 8.00
Air Flow Rate High m
3
/sec 0.13 0.13 0.13 0.13 0.18 0.21 0.28
Nom m
3
/sec 0.12 0.12 0.12 0.12 0.16 0.18 0.24
Low m
3
/sec 0.11 0.11 0.11 0.11 0.14 0.17 0.22
External Static Pressure High Pa 30.0 30.0 30.0 30.0 44.0 44.0 44.0
Low Pa 10.0 10.0 10.0 10.0 15.0 15.0 15.0
Dimensions Height x Width x Depth mm 200 x 750 x 620 200 x 950 x 620 200 x 1150 x 620
Weight kg 22 22 22 22 26 26 29
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.3 0.3 0.3 0.3 0.4 0.4 0.5
Fuse Rating amps 5
Sound Level Sound Pressure Hi Hi dBA 32.0 33.0 33.0 33.0 34.0 35.0 36.0
High dBA 31.0 31.0 31.0 31.0 32.0 33.0 34.0
Low dBA 29.0 29.0 29.0 29.0 28.0 29.0 30.0
Sound Power dBA - - - - - - -
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 1/4 3/8
Gas inches 1/2 1/2 1/2 1/2 1/2 1/2 5/8
Trade Unit Price 551.00 568.00 585.00 593.00 631.00 657.00 677.00
VRV Fan Coil Slim Ducted
FXDQ-A
Notes:
i) For accessories please refer to pages 77 - 84
ii) Fan coils supplied as standard with factory ftted flter
Integrated Solutions
V
R
V

48
Indoor Units FXSQ20P FXSQ25P FXSQ32P FXSQ40P FXSQ50P FXSQ63P FXSQ80P FXSQ100P FXSQ125P FXSQ140P
Capacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70 7.20 9.00 11.30 12.90
UK Sensible Cooling kW 1.80 2.00 2.50 3.40 3.90 4.90 6.10 7.30 8.90 10.40
UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10 7.63 9.53 12.20 13.73
UK Heating VRVIII HR only kW 2.05 2.62 3.28 4.10 5.16 6.56 8.20 10.25 13.12 14.75
Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00 16.00
Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00 10.00 12.50 16.00 18.00
Air Flow Rate High m
3
/sec 0.15 0.15 0.16 0.27 0.27 0.33 0.42 0.53 0.65 0.77
Low m
3
/sec 0.11 0.11 0.12 0.18 0.18 0.27 0.33 0.38 0.47 0.53
External Static Pressure High Pa 70.0 70.0 70.0 100.0 100.0 100.0 100.0 120.0 120.0 140.0
Low Pa 30.0 30.0 30.0 30.0 30.0 30.0 40.0 40.0 40.0 50.0
Dimensions Height x Width x Depth mm 300 x 550 x 700 300 x 700 x 700 300 x 1000 x 700 300 x 1400 x 700
Weight kg 23 23 23 26 26 35 35 46 46 47
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.4 0.4 0.4 1.2 1.2 1.1 1.3 1.6 2.1 3.1
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 32.0 32.0 33.0 37.0 37.0 37.0 38.0 38.0 40.0 42.0
Low dBA 26.0 26.0 27.0 29.0 29.0 30.0 32.0 32.0 33.0 34.0
Sound Power dBA 55 55 56 63 63 59 63 61 66 67
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 3/8 3/8 3/8 3/8 3/8
Gas inches 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8 5/8
Trade Unit Price 586.00 602.00 610.00 649.00 676.00 698.00 796.00 882.00 1,010.00 1,111.00
VRV Fan Coil Ducted with Inverter Fan
FXSQ-P
Notes:
i) For accessories please refer to pages 77 - 84
ii) Fan coils supplied as standard with factory ftted flter
Indoor Units FXMQ20P7 FXMQ25P7 FXMQ32P7 FXMQ40P7 FXMQ50P7 FXMQ63P7 FXMQ80P7 FXMQ100P7 FXMQ125P7
Capacity UK Total Cooling kW TBC TBC TBC 3.60 4.50 5.70 7.20 9.00 11.30
UK Sensible Cooling kW TBC TBC TBC 3.40 4.10 4.90 6.10 7.30 9.20
UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10 7.63 9.53 12.20
UK Heating VRVIII HR only kW 2.05 2.62 3.28 4.10 5.16 6.56 8.20 10.25 13.12
Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10 9.00 11.20 14.00
Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00 10.00 12.50 16.00
Air Flow Rate High m
3
/sec 0.15 0.15 0.15 0.27 0.30 0.33 0.42 0.53 0.65
Low m
3
/sec 0.11 0.11 0.12 0.18 0.25 0.27 0.33 0.38 0.47
External Static pressure High Pa 100.0 100.0 100.0 160.0 200.0 200.0 200.0 200.0 200.0
Low Pa 50.0 50.0 50.0 100.0 100.0 100.0 100.0 100.0 100.0
Dimensions Height x Width x Depth mm 300 x 550 x 700 300 x 700
x 700
300 x 1000 x 700 300 x 1400 x 700
Weight kg 23 23 23 26 35 35 35 46 46
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.6 0.6 0.6 1.6 1.4 1.4 1.7 2.3 2.9
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 33.0 33.0 34.0 39.0 41.0 42.0 43.0 43.0 44.0
Low dBA 29.0 29.0 30.0 35.0 37.0 38.0 39.0 39.0 40.0
Sound Power dBA 56/- 56/- 57/- 65/- 61/- 64/- 67/- 65/- 70/-
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 3/8 3/8 3/8 3/8
Gas inches 1/2 1/2 1/2 1/2 1/2 5/8 5/8 5/8 5/8
Trade Unit Price 782.00 800.00 826.00 981.00 1,045.00 1,095.00 1,151.00 1,275.00 1,460.00
VRV Fan Coil High Static Ducted
FXMQ-P7
Notes:
i) For accessories please refer to pages 77 - 84
Price List 2013 49
V
R
V

Indoor Units FXMQ200MA FXMQ250MA


Capacity UK Total Cooling kW 18.00 22.50
UK Sensible Cooling kW 14.40 17.97
UK Heating kW 19.06 24.02
UK Heating VRVIII HR only kW 20.49 25.82
Nominal Cooling kW 22.40 28.00
Nominal Heating kW 25.00 31.50
Air Flow Rate High m
3
/sec 0.97 1.20
Low m
3
/sec 0.83 1.03
External Static pressure High Pa 221.0 270.0
Low Pa 132.0 147.0
Dimensions Height x Width x Depth mm 470 x 1380 x 1100
Weight kg 137 137
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 6.5 7.2
Fuse Rating amps 13
Sound Level Sound Pressure High dBA 48.0 48.0
Low dBA 45.0 45.0
Sound Power dBA - -
Piping Connections Liquid inches 3/8 3/8
Gas inches 3/4 7/8
Trade Unit Price 2,550.00 2,610.00
VRV Fan Coil High Static Ducted
FXMQ-MA
Notes:
i) For accessories please refer to pages 77 - 84
Indoor Units FXMQ125MF FXMQ200MF FXMQ250MF
Capacity UK Total Cooling kW TBC TBC TBC
UK Sensible Cooling kW TBC TBC TBC
UK Heating kW - - -
UK Heating VRVIII HR only kW - - -
Nominal Cooling kW 14.00 22.40 28.00
Nominal Heating kW 8.90 13.90 17.40
Air Flow Rate High m
3
/sec 0.30 0.47 0.58
External Static Pressure High Pa 185.0 225.0 205.0
Dimensions Height x Width x Depth mm 470 x 744 x 1100 470 x 1380 x 1100
Weight kg 86 123 123
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 1.5
2.6
3.0
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 43.0 48.0 48.0
Low dBA -
-
-
Sound Power dBA - - -
Piping Connections Liquid inches 3/8 3/8 3/8
Gas inches 5/8 3/4 7/8
Trade Unit Price 1,906.00 3,149.00 3,220.00
VRV Fan Coil Fresh Air Processing Ducted
FXMQ-MF
Notes:
i) Please contact your local sales ofce for guidance on installing this unit
ii) For accessories please refer to pages 77 - 84
Integrated Solutions
V
R
V

50
Indoor Units FXAQ15P FXAQ20P FXAQ25P FXAQ32P FXAQ40P FXAQ50P FXAQ63P
Capacity UK Total Cooling kW TBA 1.80 2.30 2.90 3.60 4.50 5.70
UK Sensible Cooling kW TBA 1.70 1.93 2.33 3.17 3.53 4.43
UK Heating kW 1.45 1.91 2.44 3.05 3.81 4.80 6.10
UK Heating VRVIII HR only kW 1.56 2.05 2.62 3.28 4.10 5.16 6.56
Nominal Cooling kW 1.70 2.20 2.80 3.60 4.50 5.60 7.10
Nominal Heating kW 1.90 2.50 3.20 4.00 5.00 6.30 8.00
Air Flow Rate High m
3
/sec 0.12 0.13 0.13 0.15 0.20 0.25 0.32
Low m
3
/sec 0.08 0.08 0.08 0.09 0.15 0.20 0.23
Dimensions Height x Width x Depth mm 290 x 795 x 238 290 x 1050 x 238
Weight kg 11 11 11 11 14 14 14
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0 0.2 0.3 0.3 0.3 0.4 0.5
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 33 35.0 36.0 37.0 39.0 42.0 46.0
Low dBA 29 29.0 29.0 29.0 34.0 36.0 39.0
Sound Power dBA - - - - - - -
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 1/4 3/8
Gas inches 1/2 1/2 1/2 1/2 1/2 1/2 5/8
Trade Unit Price 430.00 443.00 455.00 460.00 472.00 497.00 548.00
VRV Fan Coil Wall Mounted
FXAQ-P
Notes:
i) For accessories please refer to pages 77 - 84
Indoor Units FXLQ20P FXLQ25P FXLQ32P FXLQ40P FXLQ50P FXLQ63P
Capacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70
UK Sensible Cooling kW 1.43 1.73 2.17 2.63 3.27 4.03
UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10
UK Heating VRVIII HR only kW 2.05 2.62 3.28 4.10 5.16 6.56
Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10
Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00
Air Flow Rate High m
3
/sec 0.12 0.12 0.13 0.18 0.23 0.27
Low m
3
/sec 0.10 0.10 0.10 0.14 0.18 0.20
Dimensions Height x Width x Depth mm 600 x 1000 x 232 600 x 1140 x 232 600 x 1420 x 232
Weight kg 27 27 32 32 38 38
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.2 0.2 0.5 0.5 0.5 0.5
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 35.0 35.0 35.0 38.0 39.0 40.0
Low dBA 32.0 32.0 32.0 33.0 34.0 35.0
Sound Power dBA - - - - - -
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 3/8
Gas inches 1/2 1/2 1/2 1/2 1/2 5/8
Trade Unit Price 681.00 692.00 706.00 731.00 739.00 783.00
VRV Fan Coil Floor Mounted Cased
FXLQ-P
Notes:
i) For accessories please refer to pages 77 - 84
Price List 2013 51
V
R
V

Indoor Units FXNQ20P FXNQ25P FXNQ32P FXNQ40P FXNQ50P FXNQ63P


Capacity UK Total Cooling kW 1.80 2.30 2.90 3.60 4.50 5.70
UK Sensible Cooling kW 1.50 1.80 2.20 2.70 3.40 4.20
UK Heating kW 1.91 2.44 3.05 3.81 4.80 6.10
UK Heating VRVIII HR only kW 2.05 2.62 3.28 4.10 5.16 6.56
Nominal Cooling kW 2.20 2.80 3.60 4.50 5.60 7.10
Nominal Heating kW 2.50 3.20 4.00 5.00 6.30 8.00
Air Flow Rate High m
3
/sec 0.12 0.12 0.13 0.18 0.23 0.27
Low m
3
/sec 0.10 0.10 0.10 0.14 0.18 0.20
Dimensions Height x Width x Depth mm 610 x 930 x 220 610 x 1070 x 220 610 x 1350 x 220
Weight kg 19 19 23 23 27 27
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.2 0.2 0.5 0.5 0.5 0.5
Fuse Rating amps 5
Sound Level Sound Pressure High dBA 35.0 35.0 35.0 38.0 39.0 40.0
Low dBA 32.0 32.0 32.0 33.0 34.0 35.0
Sound Power dBA - - - - - -
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 3/8
Gas inches 1/2 1/2 1/2 1/2 1/2 5/8
Trade Unit Price 606.00 616.00 628.00 651.00 657.00 698.00
VRV Fan Coil Floor Mounted Chassis
FXNQ-P
VRV Fan Coil Low Level Wall Mounted
Chassis (Medium Static) UK.FXDQ
(Available from Summer 2013)
Notes:
i) For accessories please refer to pages 77 - 84
Notes:
i) For accessories please refer to pages 77 - 84
Indoor Units UK.FXDQ15A UK.FXDQ20A UK.FXDQ25A UK.FXDQ32A UK.FXDQ40A UK.FXDQ50A UK.FXDQ63A
Capacity UK Total Cooling kW 1.40 1.80 2.30 2.90 3.60 4.50 5.70
UK Sensible Cooling kW 1.30 1.60 1.90 2.20 2.80 3.50 4.30
UK Heating kW 1.30 1.91 2.44 3.05 3.81 4.80 6.10
UK Heating VRVIII HR only kW 1.39 2.05 2.62 3.28 4.10 5.16 6.56
Nominal Cooling kW 1.70 2.20 2.80 3.60 4.50 5.60 7.10
Nominal Heating kW 1.70 2.50 3.20 4.00 5.00 6.30 8.00
Air Flow Rate High m
3
/sec 0.13 0.13 0.13 0.13 0.18 0.21 0.28
Nom m
3
/sec 0.12 0.12 0.12 0.12 0.16 0.18 0.24
Low m
3
/sec 0.11 0.11 0.11 0.11 0.14 0.17 0.22
External Static Pressure High Pa 30.0 30.0 30.0 30.0 44.0 44.0 44.0
Low Pa 10.0 10.0 10.0 10.0 15.0 15.0 15.0
Dimensions Height mm 620 x 700 x 200 620 x 950 x 200 620 x 1150 x 200
Weight kg 22 22 22 22 26 26 29
Electrical Details Power Supply Phase 1ph
Hz 50
V 230
Running Current amps 0.3 0.3 0.3 0.3 0.4 0.4 0.5
Fuse Rating amps 5
Sound Level Sound Pressure Hi Hi dBA 32.0 33.0 33.0 33.0 34.0 35.0 36.0
High dBA 31.0 31.0 31.0 31.0 32.0 33.0 34.0
Low dBA 29.0 29.0 29.0 29.0 28.0 29.0 30.0
Sound Power dBA - - - - - - -
Piping Connections Liquid inches 1/4 1/4 1/4 1/4 1/4 1/4 3/8
Gas inches 1/2 1/2 1/2 1/2 1/2 1/2 5/8
Trade Unit Price 777.00 794.00 811.00 819.00 857.00 883.00 903.00
Integrated Solutions
V
R
V

52
Small Air Curtains:
Free Hanging, Cassette and Recessed
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessory Ref Description Trade Price
BRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock 74.00
KRCS01-1 Remote room mounted temperature sensor 45.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
Accessories:
i) Biddle Remote Controller and Connection
cable Included for Fan Speed Control
ii) If RTD-20 Connected in Air Curtain
mode the Biddle Remote Controller is
NOT connected as Fan speed is Managed
by RTD-20
iii) Code BC is for white fnish.
Aluminium fnish SCavailable on request
Notes:
F = Free Hanging model C = Cassette model R = Recessed model
Biddle air curtains are the ideal solution
for retailers and consultants to combat the
issue of climate separation across their outlet or
oce doorway. Using a combination of rectier
technology, air velocity and temperature
control they deliver greater comfort to sta and
customers alike, all year round, in all weathers.
In conjunction with Biddle, Daikin VRVIII heat recovery air
curtain solution combines the benets of the Biddle air curtain
technology with the benefts of Daikin VRVIII with heat recovery.
Provides virtually free air curtain heating via recovered heat
from indoor units in cooling mode
Connection to the high COP heat recovery system enables
COPs of up to 4.36
Short payback times less than 3 years
Air curtain rectier technology deeply penetrating airstream
Constant air velocity technology all year round eciency
European patent
1.0 to 2.5 metre door widths
Door heights of 2.2 to 3.8 metres
Choice of colour RAL9010:White or RAL9006:Grey
Easy and fast installation of these systems not only reduces costs
but makes expensive water systems, boilers and gas connections
redundant. Integrating a Biddle air curtain with Daikin VRV also
eliminates the need to install multiple outdoor units thereby
reducing installation time and costs further. This combination
enables Daikin to oer its customers the ultimate
environmentally conscious TOTAL SOLUTION PACKAGE
comprising cooling, heating, outdoor-indoor climate separation
and fresh air ventilation.
Air Curtains for VRVIII Heat Recovery
BIDDLE STANDARD AIR CURTAIN - SMALL CYVS100DK80*BC CYVS150DK80*BC CYVS200DK100*BC CYVS250DK140*BC
* = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = R
Heating Capacity speed 3 kW 7.40 9.00 11.60 16.20
Delta T Inlet = room temperature speed 3 k 15 15 15 16
Power Input (50Hz) Fan only / Heating kW 0.23 / 0.23 0.35 / 0.35 0.46 / 0.46 0.58 / 0.58
Maximum Door Width m 1.00 1.50 2.00 2.50
Mounting Height *2 Max / Min m 2.7/2.0 2.7/2.0 2.7/2.0 2.7/2.0
Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270
Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548
Depth mm 590 821 561 590 821 561 590 821 561 590 821 561
Weight kg 56 59 61 66 83 88 83 102 108 107 129 137
Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010
Minimum requiring ceiling void mm 420 420 420 420
Fan - Air Flow Rate Heating speed 3 m
3
/sec 0.323 0.485 0.647 0.808
Sound Pressure Heating speed 3 dBA 47 49 50 51
Refrigerant Type R-410A R-410A R-410A R-410A
Piping Connections Liquid (OD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0
Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50
Trade Unit Price 3,046.00 3,009.00 3,137.00 3,880.00 3,843.00 4,065.00 4,689.00 4,653.00 5,027.00 5,232.00 5,195.00 5,605.00
Price List 2013 53
V
R
V

Medium Air Curtains:


Free Hanging, Cassette and Recessed
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessory Ref Description Trade Price
BRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock 74.00
KRCS01-1 Remote room mounted temperature sensor 45.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
Accessories:
i) Biddle Remote Controller and connection
cable included for Fan Speed Control
ii) If RTD-20 Connected in Air Curtain
mode the Biddle Remote Controller is
NOT connected as Fan speed is managed
by RTD-20
iii) Code BC is for white fnish.
Aluminium fnish SCavailable on request
Notes:
F = Free Hanging model C = Cassette model R = Recessed model
Large Air Curtains:
Free Hanging, Cassette and Recessed
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessory Ref Description Trade Price
BRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock 74.00
KRCS01-1 Remote room mounted temperature sensor 45.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV POA
Accessories:
i) Biddle Remote Controller and connection
cable included for Fan Speed Control
ii) If RTD-20 Connected in Air Curtain
mode the Biddle Remote Controller is
NOT connected as Fan speed is managed
by RTD-20
iii) Code BC is for white fnish.
Aluminium fnish SCavailable on request
Notes:
F = Free Hanging model C = Cassette model R = Recessed model
BIDDLE STANDARD AIR CURTAIN - MEDIUM CYVM100DK80*BC CYVM150DK80*BC CYVM200DK100*BC CYVM250DK140*BC
* = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = R
Heating Capacity speed 3 kW 9.20 11.00 13.40 19.90
Delta T Inlet = room temperature speed 3 k 17 14 13 15
Power Input (50Hz) Fan only / Heating kW 0.37 / 0.37 0.56 / 0.56 0.75 / 0.75 0.94 / 0.94
Maximum Door Width m 1.00 1.50 2.00 2.50
Mounting Height *2 Max / Min m 3.2/2.3 3.2/2.3 3.2/2.3 3.2/2.3
Dimensions Height mm 270 270 270 270 270 270 270 270 270 270 270 270
Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548
Depth mm 590 821 561 590 821 561 590 821 561 590 821 561
Weight kg 57 68 66 73 88 93 94 111 117 108 136 144
Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010
Minimum requiring ceiling void mm 420 420 420 420
Fan - Air Flow Rate Heating speed 3 m
3
/sec 0.446 0.669 0.892 1.115
Sound Pressure Heating speed 3 dBA 50 51 53 54
Refrigerant Type R-410A R-410A R-410A R-410A
Piping Connections Liquid (OD) / Gas mm 9.52/16.0 9.52/16.0 9.52/16.0 9.52/19.0
Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50
Trade Unit Price 3,484.00 3,447.00 3,576.00 4,464.00 4,427.00 4,623.00 5,531.00 5,494.00 5,867.00 6,295.00 6,258.00 6,661.00
BIDDLE STANDARD AIR CURTAIN - LARGE CYVL100DK125*BC CYVL150DK200*BC CYVL200DK250*BC CYVL250DK250*BC
* = F * = C * = R * = F * = C * = R * = F * = C * = R * = F * = C * = R
Heating Capacity speed 3 kW 15.60 23.30 29.40 31.10
Delta T Inlet = room temperature speed 3 k 15 15 14 12
Power Input (50Hz) Fan only / Heating kW 0.75 / 0.75 1.13 / 1.13 1.50 / 1.50 1.88 / 1.88
Maximum Door Width m 1.00 1.50 2.00 2.50
Mounting Height *2 Max / Min m 3.7/2.5 3.7/2.5 3.7/2.5 3.7/2.5
Dimensions Height mm 370 370 370 370 370 370 370 370 370 370 370 370
Width mm 1,000 1,000 1,048 1,500 1,500 1,548 2,000 2,000 2,048 2,500 2,500 2,548
Depth mm 774 1105 745 774 1105 745 774 1105 745 774 1105 745
Weight kg 76 81 83 100 118 141 126 151 155 157 190 196
Casing Colour white RAL9010 white RAL9010 white RAL9010 white RAL9010
Minimum requiring ceiling void mm 520 520 520 520
Fan - Air Flow Rate Heating speed 3 m
3
/sec 0.861 1.292 1.722 2.153
Sound Pressure Heating speed 3 dBA 53 54 56 57
Refrigerant Type R-410A R-410A R-410A R-410A
Piping Connections Liquid (OD) / Gas mm 9.52/16.0 9.52/19.0 9.52/22.0 9.52/22.0
Power Supply ph/V/Hz 1~/230/50 1~/230/50 1~/230/50 1~/230/50
Trade Unit Price 4,439.00 4,393.00 4,528.00 5,906.00 5,860.00 6,043.00 7,272.00 7,226.00 7,589.00 8,446.00 8,400.00 8,846.00
Integrated Solutions
V
R
V

54
Total solution heat recovery
To date, the primary operation of the VRV heat recovery system
has been to extract heat from areas of a building being cooled
and redistribute and recycle this heat for re-use in other parts
of the building with a heating requirement, often as a result of
building orientation and diversity.
However, if more heat is extracted than can be eectively
re-used this surplus heat is generally dissipated to the
atmosphere at the VRV outdoor unit and subsequently the
recovered energy is wasted.
Available for either high temperature or
low temperature water.
High temperature cascade Hydrobox suitable for heating and
hot water applications with leaving temperatures up between
25 and 80C. For connection to Heat Recovery systems REYAQ.
For this system the Hydrobox is complete with expansion
vessels, circulating pumps and controls built in as standard
For applications requiring chilled water, other capacity sizes or
dierent installation congurations, please contact your local
sales oce for advice
Possibility to integrate high temperature Hydrobox with solar
collectors for domestic hot water storage. (details & prices
available on request)
HT Hot Water Module for VRVIII Heat Recovery
Ideally positioned for the commercial sector, Daikin UK now ofers a choice of energy efcient
domestic hot water and heating solutions for w.c. facilities, kitchens and sta break out areas.
The VRVIII hot water module operates with the VRVIII heat recovery system to provide an energy
ecient means of producing hot water from recovered or recycled heat.
VRV heat recovery with
connection to heating only
hydrobox
(REYAQ10-16P)
BS-Box
BS-Box
Heating only
hydrobox for VRV
Domestic hot water
Low temp. radiator
Air handling unit
Under floor heating
VRV indoor units
25C - 35C
45C - 75C
25C - 75C
45C - 75C
Liquid pipe
F1, F2 communication
Gas pipe
Hot water
Discharge gas pipe
Thermal
store *
* Please refer to Daikin heating price list for this unit
Price List 2013 55
V
R
V

INDOOR UNIT (HYDRO BOX) HXHD125A


Function Heating & Hot water
Heating Capacity kW 14
Capacity Index 125
Dimensions HxWxD mm 705x600x695
Empty Weight kg 92
Leaving Water Temperature Range heating C 25~80
Drain valve Yes
Water Pump Yes
Expansion Vessel Yes
Material Precoated sheet metal
Colour Metalic Grey
Hydrobox Power Supply 230V Single Phase (20A)
Refrigerant Pipe Sizes 12.7mm Gas 9.52mm Gas
Water Side Pipe Sizes 1
Sound Pressure Level dBA 42
Refrigerant R134a Cascade
Trade Unit Price Hydro Box 2,660.00
ACCESSORY FOR HYDRO BOX Trade Unit Price
EKRP1HBA DigitaI/O PCB 104.00
EKRP1AHT Demand PCB 104.00
EKRUAHTB Remote user interface ( one included as standard - intregated with Hydrobox) 157.00
EKRTWA Wired Room thermostat ( Requires EKRP1AHTA) 99.00
EKRTR Wireless Room thermostat ( Requires EKRP1AHTA) 194.00
EKRTETS Floor temperature sensor for use with EKRTR ( Requires EKRP1AHTA) 14.00
HT Hot Water Module
For Connection Only to REYAQ Outdoor Series VRVIII Heat Recovery
Notes:
i) Hydroboxes are connectable to the
following outdoor series only: Air Cooled
Heat Recovery REYAQ-P (see page 66)
ii) Hydroboxes are inclusive of integral
expansion vessel, and pump
DOMESTIC UNVENTED HOT WATER TANK EKHTSU200AC EKHTSU260AC
Unvented System (Includes EKUHWHT unvented Kit as shown below)
Water Volume l 200 260
Max Water Temperature C 75
Height mm 1335 1610
Width mm 600 600
Depth mm 695 695
Empty Weight kg 81 89
Colour Metallic grey
Material Inside Tank Stainless Steel
Material Outside Casing Precoated sheet metal
Piping Connections
(Diameter)
Water inlet H/E inch 3/4
Water outlet H/E inch 3/4
Cold Water in inch 3/4
Hot water out inch 3/4
Trade Unit Price 1,113.00 1,261.00
ACCESSORIES FOR UNVENTED SYSTEMS Trade Unit Price
EKUHWHT Includes: Combined Pressure Reducing Valve, Non Return Valve, Strainer, Expansion Relief Valve,
Expansion Vessel, Tundish
Included with
EKHTSU*AC
EKFMAHTB Option for stand alone tank (ie not mounted on top of hydrobox) 277.00
HT Water Tank
Notes:
i) Hydroboxes are connectable to the
following outdoor series only: Air Cooled
Heat Recovery REYAQ-P (see page 66)
ii) Hydroboxes are inclusive of integral
expansion vessel and pump
Integrated Solutions
V
R
V

56
V
R
V

Low Temperature Hydrobox


HXY-A
Liquid pipe
F1, F2 communication
Gas pipe
Hot/cold water
Low temp. radiator
Air handling unit
Under floor heating
VRV IV heat pump
VRV indoor units
Indoor Units HXY080A HXY125A
Cooling capacity Nom. kW 8 12.5
Heating capacity Nom. kW 9 14
Casing Colour White
Material Precoated sheet metal
Dimensions Unit Height x Width x Depth mm 890 x 480 x 344
Weight Unit kg 44
Sound pressure level Nom. dBA -
Operation range Heating Ambient Min.~Max. C -20~24
Water side Min.~Max. C 25~45
Cooling Ambient Min.~Max. C ~-
Water side Min.~Max. C -~-
Refrigerant Type -
Refrigerant circuit Gas side diameter mm 15.9
Liquid side diameter mm 9.5
Water circuit Piping connections diameter inch G 11/4 (female)
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Recommended fuses A
Trade Unit Price 1,178.00 1,432.00
The low temperature Hydrobox oers air-to-water
connection to VRV IV Heat Pump and is ideal
for applications such as under oor heating, air
handling units and low temperature radiators.
Price List 2013 57
V
R
V

Outdoor Units RXYSQ4P8V1 RXYSQ5P8V1 RXYSQ6P8V1 RXYSQ4P8Y1 RXYSQ5P8Y1 RXYSQ6P8Y1


Capacity Nominal Cooling kW 12.60 14.00 15.50 12.60 14.00 15.50
Nominal Heating kW 14.20 16.00 18.00 14.20 16.00 18.00
Dimensions Height x Width x Depth mm 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320 1345 x 900 x 320
Weight kg 120 120 120 120 120 120
Air Flow Rate m
3
/sec 1.77 1.77 1.77 1.77 1.77 1.77
Electrical Details Power Supply Phase 1ph 3ph
Hz 50 50
V 230 400
Running Current amps 15.9 20.2 22.2 5.3 6.8 7.8
Starting Current amps 4 4 4 4 4 4
Fuse Rating amps 32 32 32 16 16 16
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 4.0
Additional Charge kg data book
Sound Pressure dBA 50 51 53 50 51 53
Sound Power dBA 66 67 69 66 67 69
Piping Limits Maximum Length m 300
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/8 3/8 3/8 3/8 3/8 3/8
Gas inches 5/8 5/8 3/4 5/8 5/8 3/4
Capacity Index Limit 50~130 62.5~162.5 70~182 50~130 62.5~162.5 70~182
Maximum Number of Connected Indoor Units 8 10 12 8 10 12
Trade Condensing Unit Price 2,681.00 3,014.00 3,364.00 2,681.00 3,472.00 3,734.00
VRVIII Condensing Units Heat Pump Inverter Mini
RXYSQ
Notes:
The VRV III-S is highly space saving, featuring a slimmer and more compact outdoor unit compared to conventional models. Supplied in three sizes of 4 HP (11.2 kW), 5HP (14 kW) and 6HP
(15.5 kW) with a single or three phase power supply. Compatible with the full range of existing VRV fan coil units providing a choice of 12 types and 72 models. Installation is improved by the
completely new casing design of the outdoor unit with a footprint of just 320mm deep by 900mm wide, which reduces installation space requirements by over 40% (14.0kW model) and enables it
to ft easily onto balconies and narrow ledges. Maximum piping length is 150m, total piping length is 300m and maximum vertical diferential between outdoor and indoor units is 50m (40m when
outdoor is below indoor units). The Daikin Super Wiring system allows shared use of the wiring between indoor and outdoor units and the centralised remote control, the non polarity of the system
obviating incorrect connection and reducing installation time.
Smooth air inlet bell mouth
and aero spiral fan
These features assist in significantly reducing noise.
Guides are added to the bell mouth intake to reduce
turbulence in the air flow generated by fan suction.
The aero spiral fan features fan blades with bent blade
edges, further reducing turbulence.
Super aero grille
The spiral shaped ribs are aligned with the direction
of discharge flow in order to minimise turbulence and
reduce noise.
e-Bridge circuit
Prevents accumulation of liquid refrigerant in the
condenser. This results in more efficient use of the
condenser surface under all conditions and leads in turn
to better energy efficiency. Increased evaporative capacity
stems from the newly developed refrigeration circuit, the
SCe-bridge circuit, which adds super cooling prior to the
expansion cycle. By adopting this circuit, the COPs in both
cooling and heating have been drastically improved.
Advanced technologies
1
2
3
Conventional New
Escaping edges are sucked in by the bent blade edges, reducing overall turbulence.
Aero spiral fan blade tips
1
2
3
Integrated Solutions
V
R
V

58
Heat Pump VRVIV
RYYQ-T
Replaces RXYQ-P9 / RXYHQ-P9 / RXYRQ-P9 / RXHQ-P
Outdoor Units RYYQ8T RYYQ10T RYYQ12T RYYQ14T RYYQ16T RYYQ18T RYYQ20T
Capacity Nominal Cooling kW 22.40 28.00 33.50 40.00 45.00 50.00 56.00
Nominal Heating kW 25.00 31.50 37.50 45.00 50.00 56.00 63.00
EER 4.30 3.84 3.73 3.64 3.46 3.40 3.03
ESEER 7.53* 7.2* 6.96* 6.83* 6.5* 6.38* 5.67*
COP 4.55 4.27 4.12 4.02 3.91 3.89 3.71
Dimensions Height x Width x Depth mm 1685 x 930 x 765 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765 1685 x 1240 x 765 1685 x 1240 x 765 1685 x 1240 x 765
Weight kg 261 268 268 364 364 398 398
Air Flow Rate m
3
/sec 2.70 2.92 3.08 3.72 4.33 4.18 4.35
External Static Pressure High Pa 78 78 78 78 78 78 78
Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V
Running Current amps 7.2 11.3 12.7 15.4 18.0 20.8 26.9
Starting Current amps databook
Fuse Rating amps 20 25 32 32 40 40 50
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 5.9 6.0 6.3 10.3 10.4 11.7 11.8
Additional Charge kg data book
Sound Pressure dBA 58 58 61 61 64 65 66
Sound Power dBA 78 79 81 81 86 86 88
Piping Limits Maximum Length m 165 165 165 165 165 165 165
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/8 3/8 1/2 1/2 1/2 5/8 5/8
Gas inches 3/4 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8
Capacity Index Limit 100~260 125~325 150~390 175~455 200~520 225~585 250~650
Maximum Number of Connected Indoor Units 64 64 64 64 64 64 64
Trade Condensing Unit Price 4,453.00 4,866.00 5,958.00 6,951.00 8,023.00 8,937.00 9,830.70
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
VRVIV Heat Pump with Continuous Heating
RYYQ-T (up to 20 HP)
3 revolutionary features:
Variable refrigerant temperature
Customise your VRV for best Seasonal Efciency and comfort:
Revolutionary variable refrigerant temperature control
automatically adapts the system to individual building and
climate requirements for greater eciency and comfort
Continuously adjusts refrigerant temperature to the actual
temperature and capacity required
Default mode optimised by Daikin for UK conditions with
maximum eciency and comfort
Delivers annual cost savings of up to 25%
Continuous heating during defrost
The new standard in heating comfort:
Unique continuous heating technology makes VRVIV Heat
Pump the best alternative to traditional heating systems
Delivers uninterrupted heat, even during the defrost cycle
Maintains comfortable indoor climate at all times
VRV confgurator
Advanced software for simplifed commissioning,
servicing, confguration and customisation:
Simplied commissioning: graphical interface to congure,
commission and upload system settings
Simplied servicing: additional 7-segment indicator for easy
and quick access to basic functions and error read out
Manage systems over multiple sites
Price List 2013 59
V
R
V

Outdoor Units RYYQ22T RYYQ24T


RYMQ10T RYMQ12T RYMQ8T RYMQ16T
Capacity Nominal Cooling kW 61.50 67.40
Nominal Heating kW 69.00 75.00
EER 3.77 3.70
ESEER 7.07* 6.81*
COP 4.18 4.10
Dimensions Height x Width x Depth mm 1685 x 930 x 765 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765
Weight kg 195 195 188 309
Air Flow Rate m
3
/sec 2.92 3.08 2.70 4.33
External Static Pressure High Pa 78 78 78 78
Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V
Running Current amps 10.2 12.7 7.2 18.0
Starting Current amps databook
Fuse Rating amps 25 32 20 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 6.0 6.3 5.9 10.4
Additional Charge kg databook
Sound Pressure dBA 58 61 58 64
Sound Power dBA 79 81 78 86
Piping Limits Maximum Length m 165 165
Maximum Vertical Rise m databook
Piping Connections Liquid inches 5/8 5/8
Gas inches 1 1/8 1 3/8
Capacity Index Limit 275~715 300~780
Maximum Number of Connected Indoor Units 64 64
Trade Condensing Unit Price 10,824.00 12,476.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Outdoor Units RYYQ26T RYYQ28T RYYQ30T RYYQ32T RYYQ34T
RYMQ12T RYMQ14T RYMQ12T RYMQ16T RYMQ12T RYMQ18T RYMQ16T RYMQ16T RYMQ16T RYMQ18T
Capacity Nominal Cooling kW 73.50 78.50 83.50 90.00 95.00
Nominal Heating kW 82.50 87.50 93.50 100.00 106.00
EER 3.68 3.57 3.52 3.46 3.43
ESEER 6.89* 6.69* 6.6* 6.5* 6.44*
COP 4.06 4.00 3.98 3.91 3.90
Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685 1685
Width mm 930 1240 930 1240 930 1240 1240 1240 1240 1240
Depth mm 765 765 765 765 765 765 765 765 765 765
Weight kg 195 309 195 309 195 319 309 309 309 319
Air Flow Rate m
3
/sec 3.08 3.72 3.08 4.33 3.08 4.18 4.33 4.33 4.33 4.18
External Static Pressure High Pa 78 78 78 78 78 78 78 78 78 78
Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V
Running Current amps 12.7 15.4 12.7 18.0 12.7 20.8 18.0 18.0 18.0 20.8
Starting Current amps databook
Fuse Rating amps 32 32 32 40 32 40 40 40 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 6.3 10.3 6.3 10.4 6.3 11.7 10.4 10.4 10.4 11.7
Additional Charge kg data book
Sound Pressure dBA 61 61 61 64 61 65 64 64 64 65
Sound Power dBA 81 81 81 86 81 86 86 86 86 86
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/4 3/4 3/4 3/4 3/4
Gas inches 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8
Capacity Index Limit 325~845 350~910 375~975 400~1040 425~1105
Maximum Number of Connected Indoor Units 64 64 64 64 64
Trade Condensing Unit Price 12,909.00 13,981.00 14,895.00 16,046.00 16,960.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
VRVIV Heat Pump with Continuous Heating
RYYQ-T (22 to 24 HP)
VRVIV Heat Pump with Continuous Heating
RYYQ-T (26 to 34 HP)
Integrated Solutions
V
R
V

60
Outdoor Units RYYQ36T RYYQ38T RYYQ40T RYYQ42T
RYMQ16T RYMQ20T RYMQ8T RYMQ10T RYMQ20T RYMQ10T RYMQ12T RYMQ18T RYMQ10T RYMQ16T RYMQ16T
Capacity Nominal Cooling kW 101.00 106.00 112.00 118.00
Nominal Heating kW 113.00 120.00 125.00 132.00
EER 3.21 3.42 3.61 3.54
ESEER 6.02* 6.36* 6.74* 6.65*
COP 3.79 4.01 4.05 4.00
Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685 1685 1685
Width mm 1240 1240 930 930 1240 930 930 1240 930 1240 1240
Depth mm 765 765 765 765 765 765 765 765 765 765 765
Weight kg 309 319 188 195 319 195 195 319 195 309 309
Air Flow Rate m
3
/sec 4.33 4.35 2.70 2.92 4.35 2.92 3.08 4.18 2.92 4.33 4.33
External Static Pressure High Pa 78 78 78 78 78 78 78 78 78 78 78
Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V
Running Current amps 18.0 26.9 7.2 10.2 26.9 10.2 12.7 20.8 10.2 18.0 18.0
Starting Current amps databook databook databook databook
Fuse Rating amps 40 50 20 25 50 25 32 40 25 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.4 11.8 5.9 6.0 11.8 6.0 6.3 11.7 6.0 10.4 10.4
Additional Charge kg data book
Sound Pressure dBA 64 66 58 58 66 58 61 65 58 64 64
Sound Power dBA 86 88 78 79 88 79 81 86 79 86 86
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/4 3/4 3/4 3/4
Gas inches 1 5/8 1 5/8 1 5/8 1 5/8
Capacity Index Limit 450~1170 475~1235 500~1300 525~1365
Maximum Number of Connected Indoor Units 64 64 64 64
Trade Condensing Unit Price 17,853.70 19,149.70 19,761.00 20,912.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Outdoor Units RYYQ44T RYYQ46T RYYQ48T
RYMQ12T RYMQ16T RYMQ16T RYMQ14T RYMQ16T RYMQ16T RYMQ16T RYMQ16T RYMQ16T
Capacity Nominal Cooling kW 124.00 130.00 135.00
Nominal Heating kW 138.00 145.00 150.00
EER 3.54 3.51 3.46
ESEER 6.62* 6.6* 6.5*
COP 3.98 3.94 3.91
Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685
Width mm 930 1240 1240 1240 1240 1240 1240 1240 1240
Depth mm 765 765 765 765 765 765 765 765 765
Weight kg 195 309 309 309 309 309 309 309 309
Air Flow Rate m
3
/sec 3.08 4.33 4.33 3.72 4.33 4.33 4.33 4.33 4.33
External Static Pressure High Pa 78 78 78 78 78 78 78 78 78
Electrical Details Power Supply Phase /Hz / V 3ph / 50 Hz / 380~415V
Running Current amps 12.7 18.0 18.0 15.4 18.0 18.0 18.0 18.0 18.0
Starting Current amps databook databook databook
Fuse Rating amps 32 40 40 32 40 40 40 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 6.3 10.4 10.4 10.3 10.4 10.4 10.4 10.4 10.4
Additional Charge kg data book
Sound Pressure dBA 61 64 64 61 64 64 64 64 64
Sound Power dBA 81 86 86 81 86 86 86 86 86
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/4 3/4 3/4
Gas inches 1 5/8 1 5/8 1 5/8
Capacity Index Limit 550~1430 575~1495 600~1560
Maximum Number of Connected Indoor Units 64 64 64
Trade Condensing Unit Price 22,004.00 22,997.00 24,069.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
VRVIV Heat Pump with Continuous Heating
RYYQ-T (36 to 42 HP)
VRVIV Heat Pump with Continuous Heating
RYYQ-T (44 to 48 HP)
Price List 2013 61
V
R
V

Outdoor Units RYYQ50T RYYQ52T RYYQ54T


RYMQ16T RYMQ16T RYMQ18T RYMQ16T RYMQ18T RYMQ18T RYMQ18T RYMQ18T RYMQ18T
Capacity Nominal Cooling kW 140.00 145.00 150.00
Nominal Heating kW 156.00 162.00 168.00
EER 3.44 3.42 3.40
ESEER 6.46* 6.42* 6.38*
COP 3.90 3.89 3.89
Dimensions Height mm 1685 1685 1685 1685 1685 1685 1685 1685 1685
Width mm 1240 1240 1240 1240 1240 1240 1240 1240 1240
Depth mm 765 765 765 765 765 765 765 765 765
Weight kg 309 309 319 309 319 319 319 319 319
Air Flow Rate m
3
/sec 4.33 4.33 4.18 4.33 4.18 4.18 4.18 4.18 4.18
External Static Pressure High Pa 78 78 78 78 78 78 78 78 78
Electrical Details Power Supply Phase 3ph / 50 Hz / 380~415V
Running Current amps 18.0 18.0 20.8 18.0 20.8 20.8 20.8 20.8 20.8
Starting Current amps databook databook databook
Fuse Rating amps 40 40 40 40 40 40 40 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.4 10.4 11.7 10.4 11.7 11.7 11.7 11.7 11.7
Additional Charge kg data book
Sound Pressure dBA 64 64 65 64 65 65 65 65 65
Sound Power dBA 86 86 86 86 86 86 86 86 86
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/4 3/4 3/4
Gas inches 1 5/8 1 5/8 1 5/8
Capacity Index Limit 625~1625 650~1690 675~1755
Maximum Number of Connected Indoor Units 64 64 64
Trade Condensing Unit Price 24,983.00 25,897.00 26,811.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
VRVIV Heat Pump with Continuous Heating
RYYQ-T (50 to 54 HP)
Integrated Solutions
V
R
V

62
Outdoor Units REYQ8P9 REYQ10P8 REYQ12P9 REYQ14P8 REYQ16P8
Capacity Nominal Cooling kW 22.40 28.00 33.50 40.00 45.00
Nominal Heating kW 25.00 31.50 37.50 45.00 50.00
Dimensions Height x Width x Depth mm 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765
Weight kg 331 331 331 339 339
Air Flow Rate m
3
/sec 3.17 3.17 3.50 3.92 4.00
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 11.7 13.8 16.0 18.4 23.8
Starting Current amps 74 74 75 4 4
Fuse Rating amps 20 25 25 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.3 10.6 10.8 11.1 11.1
Additional Charge kg data book
Sound Pressure dBA 58 58 60 62 63
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections -
Systems
Liquid inches 3/8 3/8 1/2 1/2 1/2
Gas inches 3/4 7/8 1 1/8 1 1/8 1 1/8
Discharge inches 5/8 3/4 3/4 7/8 7/8
Capacity Index Limit 100~260 125~325 150~390 175~455 200~520
Maximum Number of Connected Indoor Units 13 16 19 22 26
Trade Condensing Unit Price 4,886.00 5,368.00 6,509.00 7,674.00 9,043.00
VRVIII Condensing Units Heat Recovery
REYQ-P9 Compact (up to 16 HP)
Outdoor Units REYQ18P9 REYQ20P9 REYQ22P8 REYQ24P8
REMQ8P9 REMQ10P8 REMQ8P9 REMQ12P8 REMQ10P8 REMQ12P8 REMQ12P8 REMQ12P8
Capacity Nominal Cooling kW 50.40 55.90 61.50 67.00
Nominal Heating kW 56.50 62.50 69.00 75.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 930 930 930 930 930 930 930 930
Depth mm 765 765 765 765 765 765 765 765
Weight kg 204 254 204 254 254 254 254 254
Air Flow Rate m
3
/sec 3.00 3.08 3.00 3.33 3.08 3.33 3.33 3.33
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 8.9 + 12.2 8.9 + 14.9 12.2 + 14.9 14.9 + 14.9
Starting Current amps 78 79 88 88
Fuse Rating amps 25 25 25 25 25 25 25 25
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 8.2 9.0 8.2 9.1 9.0 9.1 9.1 9.1
Additional Charge kg data book
Sound Pressure dBA 58 58 58 60 58 60 60 60
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections -
Systems
Liquid inches 5/8 5/8 5/8 5/8
Gas inches 1 1/8 1 1/8 1 1/8 1 3/8
Discharge inches 7/8 1 1/8 1 1/8 1 1/8
Oil Equalising inches 3/4 3/4 3/4 3/4
Capacity Index Limit 225~585 250~650 275~715 300~780
Maximum Number of Connected Indoor Units 29 32 35 39
Trade Condensing Unit Price 10,254.00 11,395.00 11,877.00 13,018.00
VRVIII Condensing Units Heat Recovery
REYQ-P9 Compact (18 to 24 HP)
Price List 2013 63
V
R
V

Outdoor Units REYQ26P8 REYQ28P8 REYQ30P8 REYQ32P8


REMQ10P8 REMQ16P8 REMQ12P8 REMQ16P8 REMQ14P8 REMQ16P8 REMQ16P8 REMQ16P8
Capacity Nominal Cooling kW 73.00 78.50 85.00 90.00
Nominal Heating kW 81.50 87.50 95.00 100.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 930 1240 930 1240 1240 1240 1240 1240
Depth mm 765 765 765 765 765 765 765 765
Weight kg 254 334 254 334 334 334 334 334
Air Flow Rate m
3
/sec 3.08 3.83 3.33 3.83 3.83 3.83 3.83 3.83
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 12.2 + 22.5 14.9 + 22.5 19.6 + 22.5 22.5 + 22.5
Starting Current amps 98 98 108 109
Fuse Rating amps 25 40 25 40 40 40 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 9.0 11.7 9.1 11.7 11.7 11.7 11.7 11.7
Additional Charge kg data book
Sound Pressure dBA 58 63 60 63 62 63 63 63
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/4 3/4 3/4 3/4
Gas inches 1 3/8 1 3/8 1 3/8 1 3/8
Discharge inches 1 1/8 1 1/8 1 1/8 1 1/8
Oil Equalising inches 3/4 3/4 3/4 3/4
Capacity Index Limit 325~845 350~910 375~975 400~1040
Maximum Number of Connected Indoor Units 42 45 48 52
Trade Condensing Unit Price 14,411.00 15,552.00 16,717.00 18,086.00
VRVIII Condensing Units Heat Recovery
REYQ-P9 Compact (26 to 32 HP)
Outdoor Units REYQ34P9 REYQ36P9 REYQ38P8
REMQ8P9 REMQ10P8 REMQ16P8 REMQ8P9 REMQ12P8 REMQ16P8 REMQ10P8 REMQ12P8 REMQ16P8
Capacity Nominal Cooling kW 95.40 101.00 107.00
Nominal Heating kW 107.00 113.00 119.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 930 930 1240 930 930 1240 930 930 1240
Depth mm 765 765 765 765 765 765 765 765 765
Weight kg 204 254 334 204 254 334 254 254 334
Air Flow Rate m
3
/sec 3.00 3.08 3.83 3.00 3.33 3.83 3.08 3.33 3.83
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 8.9 + 12.2 + 22.5 8.9 + 14.9 + 22.5 12.2 + 14.9 + 22.5
Starting Current amps 101 102 111
Fuse Rating amps 25 25 40 25 25 40 25 25 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 8 9 12 8 9 12 9 9 12
Additional Charge kg data book
Sound Pressure dBA 58 58 63 58 60 63 58 60 63
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/4 3/4 3/4
Gas inches 1 3/8 1 5/8 1 5/8
Discharge inches 1 1/8 1 1/8 1 3/8
Oil Equalising inches 3/4 3/4 3/4
Capacity Index Limit 425~1105 450~1170 475~1235
Maximum Number of Connected Indoor Units 55 58 61
Trade Condensing Unit Price 19,297.00 20,438.00 20,920.00
VRVIII Condensing Units Heat Recovery
REYQ-P9 Compact (34 to 38 HP)
Integrated Solutions
V
R
V

64
Outdoor Units REYQ40P8 REYQ42P8 REYQ44P8
REMQ12P8 REMQ12P8 REMQ16P8 REMQ10P8 REMQ16P8 REMQ16P8 REMQ12P8 REMQ16P8 REMQ16P8
Capacity Nominal Cooling kW 112.00 118.00 124.00
Nominal Heating kW 125.00 132.00 138.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 930 930 1240 930 1240 1240 930 1240 1240
Depth mm 765 765 765 765 765 765 765 765 765
Weight kg 254 254 334 254 334 334 254 334 334
Air Flow Rate m
3
/sec 3.33 3.33 3.83 3.08 3.83 3.83 3.33 3.83 3.83
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 14.9 + 14.9 + 22.5 12.2 + 22.5 + 22.5 14.9 + 22.5 + 22.5
Starting Current amps 111 122 122
Fuse Rating amps 25 25 40 25 40 40 25 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 9 9 12 9 12 12 9 12 12
Additional Charge kg data book
Sound Pressure dBA 60 60 63 58 63 63 60 63 63
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/4 3/4 3/4
Gas inches 1 5/8 1 5/8 1 5/8
Discharge inches 1 3/8 1 3/8 1 3/8
Oil Equalising inches 3/4 3/4 3/4
Capacity Index Limit 500~1300 525~1365 550~1430
Maximum Number of Connected Indoor Units 64 64 64
Trade Condensing Unit Price 22,061.00 23,454.00 24,595.00
VRVIII Condensing Units Heat Recovery
REYQ-P9 Compact (40 to 44 HP)
Outdoor Units REYQ46P8 REYQ48P8
REMQ14P8 REMQ16P8 REMQ16P8 REMQ16P8 REMQ16P8 REMQ16P8
Capacity Nominal Cooling kW 130.00 135.00
Nominal Heating kW 145.00 150.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680
Width mm 1240 1240 1240 1240 1240 1240
Depth mm 765 765 765 765 765 765
Weight kg 334 334 334 334 334 334
Air Flow Rate m
3
/sec 3.83 3.83 3.83 3.83 3.83 3.83
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 19.6 + 22.5 + 22.5 22.5 + 22.5 + 22.5
Starting Current amps 132 134
Fuse Rating amps 40 40 40 40 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 12 12 12 12 12 12
Additional Charge kg data book
Sound Pressure dBA 62 63 63 63 63 63
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections Liquid inches 3/4 3/4
Gas inches 1 5/8 1 5/8
Discharge inches 1 3/8 1 3/8
Oil Equalising inches 3/4 3/4
Capacity Index Limit 575~1495 600~1560
Maximum Number of Connected Indoor Units 64 64
Trade Condensing Unit Price 25,760.00 27,129.00
VRVIII Condensing Units Heat Recovery
REYQ-P9 Compact (46 to 48 HP)
Price List 2013 65
V
R
V

Outdoor Units REYQ8P9 REYQ10P8 REYQ12P9 REYHQ16P


REMQ8P9 REMQ8P9
Capacity Nominal Cooling kW 22.40 28.00 33.50 45.00
Nominal Heating kW 25.00 31.50 37.50 50.00
Dimensions Height mm 1680 1680 1680 1680 1680
Width mm 1300 1300 1300 930 930
Depth mm 765 765 765 765 765
Weight kg 331 331 331 204 204
Air Flow Rate m
3
/sec 3.17 3.17 3.50 3.00 3.00
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 12 14 16 8.9 + 8.9
Starting Current amps 74 74 75 4
Fuse Rating amps 20 25 25 25 25
Refrigerant Circuit Refrigerant Type R410a R410a
Refrigerant Charge kg 10.3 10.6 10.8 8.2 8.2
Additional Charge kg data book data book
Sound Pressure dBA 58 58 60 58 58
Piping Limits Maximum Length m 165 165 165 165
Maximum Vertical Rise m data book data book
Piping Connections -
Systems
Liquid inches 3/8 3/8 1/2 1/2
Gas inches 3/4 7/8 1 1/8 1 1/8
Discharge inches 5/8 3/4 3/4 N/A
Capacity Index Limit 100~260 125~325 150~390 200~520
Maximum Number of Connected Indoor Units 13 16 19 26
Trade Condensing Unit Price 4,886.00 5,368.00 6,509.00 9,772.00
VRVIII Condensing Units Heat Recovery
REYQ-P9 High COP (up to 16 HP)
Outdoor Units REYQ18P9 REYHQ20P REYHQ22P REYHQ24P
REMQ8P9 REMQ10P8 REMQ8P9 REMHQ12P8 REMQ10P8 REMHQ12P8 REMHQ12P8 REMHQ12P8
Capacity Nominal Cooling kW 50.40 55.90 61.50 67.00
Nominal Heating kW 56.50 62.50 69.00 75.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 930 930 930 1240 930 1240 1240 1240
Depth mm 765 765 765 765 765 765 765 765
Weight kg 204 254 204 334 254 334 334 334
Air Flow Rate m
3
/sec 3.00 3.08 3.00 3.83 3.08 3.83 3.83 3.83
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 8.9 + 12.2 8.9 + 19.6 12.2 + 19.6 19.6 + 19.6
Starting Current amps 78 79 88 88
Fuse Rating amps 25 25 25 40 25 40 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 8.2 9.0 8 12 9 12 12 12
Additional Charge kg data book
Sound Pressure dBA 58 58 58 60 58 60 60 60
Piping Limits Maximum Length m 165
Maximum Vertical Rise m data book
Piping Connections -
Systems
Liquid inches 5/8 5/8 5/8 5/8
Gas inches 1 1/8 1 1/8 1 1/8 1 3/8
Discharge inches 7/8 1 1/8 1 1/8 1 1/8
Oil Equalising inches 3/4 3/4 3/4 3/4
Capacity Index Limit 225~585 250~650 275~715 300~780
Maximum Number of Connected Indoor Units 29 32 35 39
Trade Condensing Unit Price 10,254.00 12,490.00 12,972.00 15,208.00
VRVIII Condensing Units Heat Recovery
REYQ-P9 High COP (18 to 24 HP)
Integrated Solutions
V
R
V

66
Outdoor Units REYAQ10P REYAQ12P REYAQ14P REYAQ16P
Capacity Nominal Cooling kW 28.00 33.50 40.00 45.00
Nominal Heating kW 31.50 37.50 45.00 50.00
Dimensions Height x Width x Depth mm 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765 1680 x 1300 x 765
Weight kg 331 331 339 339
Air Flow Rate m
3
/sec 3.17 3.50 3.92 4.00
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 22.1 22.3 32.8 33.0
Starting Current amps 74 75 4 4
Fuse Rating amps 25 25 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.6 10.8 11.1 11.1
Additional Charge kg data book
Sound Pressure dBA 58 60 62 63
Piping Limits Maximum Length m 100
Maximum Vertical Rise m data book
Piping Connections -
Systems
Liquid inches 3/8 1/2 1/2 1/2
Gas inches 7/8 1 1/8 1 1/8 1 1/8
Discharge inches 3/4 3/4 7/8 7/8
Capacity Index Limit - - - -
Maximum Number of Connected Indoor Units - - - -
Trade Condensing Unit Price 4,467.00 5,559.00 6,552.00 7,624.00
VRVIII Condensing Units Heat Recovery
Connection to HT Water Module REYAQ
Notes:
i) *The REYAQ Heat Recovery Condensing unit range is designed for connection to systems that incorporate the HXHD125 high temperature hot water module
in conjunction with the standard range of VRV fan coil units.
Outdoor Units RWEYQ8P RWEYQ10P RWEYQ16P RWEYQ18P RWEYQ20P RWEYQ24P
RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ8P RWEYQ8P RWEYQ10P RWEYQ10P RWEYQ10P RWEYQ8P RWEYQ8P RWEYQ8P
Capacity Nominal Cooling kW 22.40 26.70 44.80 49.10 53.40 67.20
Nominal Heating kW 25.00 31.50 50.00 56.50 63.00 75.00
Dimensions Height x Width x Depth mm 1000 x 780 x 550
Weight kg 150 150 150 150 150 150 150 150 150 150 150
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 7.2 9.5 7.2 | 7.2 7.2 | 9.5 9.5 | 9.5 7.2 | 7.2 | 7.2
Starting Current amps 4 4 4 4 4 4
Fuse Rating amps 25 25 25 25 25 25 25 25 25 25 25
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 3.5 4.2 3.5 3.5 3.5 4.2 4.2 4.2 3.5 3.5 3.5
Additional Charge kg data book data book data book data book data book data book
Sound Pressure dBA 50 51 50 | 50 50 | 51 51 | 51 50 | 50 | 50
Piping Limits Maximum Length m 120 120 120 120 120 120
Maximum Vertical Rise m 50 50 50 50 50 50
Piping Connections Liquid inches 3/8 3/8 1/2 5/8 5/8 3/4
Gas inches 3/4 7/8 1 1/8 1 1/8 1 1/8 1 3/8
Discharge pipe size - Heat Recovery Only inches - - - - - -
Capacity Index Limit 100~260 125~325 200~520 225~585 250~650 300~780
Maximum Number of Connected Indoor Units 13 16 26 29 32 36
Trade Condensing Unit Price 5,416.00 6,674.00 10,832.00 12,090.00 13,348.00 16,248.00
VRVIII Water Cooled Condensing Units
Heat Pump and Heat Recovery RWEYQ
Notes:
Daikin have introduced the new VRVIII Water Cooled condensing unit to compliment the rest of the VRV range.
The water cooled system has a number of advantages over an air cooled system:
suitable for tall multi-storied buildings due to no limitations of water piping length
wide operation range with inlet water temperatures of 10-45C
suitable for use with open and closed loop ground source systems on request
the system ofers greater efciency in heating mode as there is no defrost cycle required for the water loop
greater efciencies than air cooled systems
Price List 2013 67
V
R
V

Outdoor Units RWEYQ26P RWEYQ28P RWEYQ30P


RWEYQ8P RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P RWEYQ10P RWEYQ10P RWEYQ10P RWEYQ10P
Capacity Nominal Cooling kW 71.50 75.80 80.10
Nominal Heating kW 81.50 88.00 94.50
Dimensions Height x Width x Depth mm 1000 x 780 x 550
Weight kg 150 150 150 150 150 150 150 150 150
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 7.2 | 7.2 | 9.5 7.2 | 9.5 | 9.5 9.5 | 9.5 | 9.5
Starting Current amps 4.0 4.0 4.0
Fuse Rating amps 25 25 25 25 25 25 25 25 25
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 4 4 4 4 4 4 4 4 4
Additional Charge kg data book
Sound Pressure dBA 50 | 50 | 51 50 | 51 | 51 51 | 51 | 51
Piping Limits Maximum Length m 120 120 120
Maximum Vertical Rise m 50 50 50
Piping Connections Liquid inches 3/4 3/4 3/4
Gas inches 1 3/8 1 3/8 1 3/8
Discharge pipe size - Heat Recovery Only inches - - -
Capacity Index Limit 325~845 350~910 375~975
Maximum Number of Connected Indoor Units 36 36 36
Trade Condensing Unit Price 17,506.00 18,764.00 20,022.00
VRVIII Water Cooled Condensing Units
Heat Pump and Heat Recovery RWEYQ
Notes:
The new VRV-WIII system is supplied as a common unit and can be used in either heat pump and heat recovery modes, from size 10 to size 30 all using a three phase power supply.
The 30 hp system can connect to up to 36 indoor units. The system is fully compatible with the full range of existing VRV fan coils and controls packages.
The condensing unit is small with a foot print of 780 x 550 mm and a height of 1000 mm. Running quality with a sound pressure level of 51dB(A), it should be installed in a plant room.
Independent Unit Outdoor Unit RWEYQ8PR RWEYQ10PR
Capacity Cooling kW 22.4 26.7
Heating kW 25 31.5
Dimensions Unit Height mm 1,000
Width mm 780
Depth mm 550
Weight Unit kg 149 150
Sound Pressure
(Nominal)
Cooling dBA 50 51
Inlet Water
Temperature
Cooling C 10~45
Heating C -10~45
Refrigerant R-410A
Power Supply 3~/400V/50Hz
Piping connections Liquid (OD) HP / HR mm 9.52 / 9.52
Gas HP / HR mm - / 19.1 - / 22.2
Discharge gas HP / HR mm 19.1 / 15.9 22.2 / 19.1
Max total length m 300
Max no. of indoor units to be connected 13 16
Trade Condensing Unit Price 5,416.00 6,674.00
VRVIII Water Cooled Condensing Units
Geothermal Application RWEYQ-PR
Heating with ground sourced water as a renewable energy source!
Groundwater remains at a relatively constant temperature during the year
Superior eciency remains even at extreme outdoor temperatures
Uses renewable energy: closed loop energy transfer with ground,
lake and river
Extension of the operation range down to -10C in heating:
Add ethylene glycol to the water when the water inlet temperature is
lower than 5C
No multi combinations possible
Heat Pump and Heat Recovery systems
Integrated Solutions
V
R
V

68
V
R
V

Benefts:
Dramatically reduced installed cost
up to 50% saving compared with a
complete new system
Re-use all existing pipework and possibly
existing fan coils
Flexibility to use with existing pipework
connected to other non-Daikin systems
Automatic charging and pipework
cleaning function
Higher energy eciency of up to 50%
and lower CO
2
emissions than retrotting
refrigerant
Major potential to increase
system capacity
10 HP 16 HP
1.
2.
1. Keep main piping 2. Add indoor units
R22 is a hydrochlorouorocarbon (HCFC) which was commonly used in air conditioning systems.
However, both new and recycled sources of R22 are banned from January 2015. Many systems today
are still running on R22, but as supplies of R22 run low, nows the time to replace R22 systems. The good
news is that Daikins VRV-Q solution delivers signicantly higher energy eciencies, with the potential of
saving up to 50%, compared with installing a completely new system.
Replacement VRV: VRVIII-Q
The benefts:
Increasing efciencies
Upgrading an old R22 system to a VRV-Q system will increase
system eciency by more than 40%, thanks to recent
developments in heat pump technology and the more ecient
R-410A refrigerant.
Fast installation
Installation is quicker because the existing piping and indoor
units (in some cases) can be retained, while Daikins unique
automatic refrigerant charging and refrigerant pipe cleaning cuts
installation time too.
System history doesnt restrict future usability
As a result of the combined refrigerant pipe cleaning and
automatic charging function, the piping network is completely
clean and suitable for re-use.
Limited and planned downtime
The installation is less intrusive and time consuming than for a
completely new system. Downtime can be carefully planned,
whereas if a problem occurs when not enough reclaimed R22 is
available, a long and unplanned downtime may occur.
Phased investment cost
Because the entire R22 system does not need to be replaced, it is
possible to upgrade the system in phases. The R22 replacement
programme can therefore be incorporated in the general
refurbishment schedule of the building, thus spreading the
investment cost.
Warranty
Unlike using drop-in refrigerants, the VRV-Q condensing unit is
provided with a manufacturers warranty, providing the existing
pipework condition is deemed suitable for re-use (see price list).
Possibility to increase capacity
Cooling loads often increase subsequent to the initial installation
of the air conditioning system. The Replacement VRV (VRV-Q)
enables system capacity to be increased without changing the
refrigerant piping (depending on system characteristics). For
example: It is possible to install a 16 HP Replacement VRV on the
refrigerant piping of an R-22 10 HP system.
Price List 2013 69
V
R
V

Outdoor Units RQYQ140P RQYQ8P RQYQ10P RQYQ12P RQYQ14P RQYQ16P


Capacity Nominal Cooling kW 14.00 22.40 28.00 33.50 40.00 45.00
Nominal Heating kW 16.00 25.00 31.50 37.50 45.00 50.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680
Width mm 635 930 930 930 1240 1240
Depth mm 765 765 765 765 765 765
Weight kg 175 230 284 284 381 381
Air Flow Rate m
3
/sec 1.58 3.00 3.08 3.33 3.88 3.88
External Static Pressure High Pa 78 78 78 78 78 78
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 5.5 8.9 12.2 14.9 19.6 22.5
Starting Current amps 4 4 74 75 84 85
Fuse Rating amps 15 25 25 25 35 35
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 11.1 10.8 11.7 11.7 11.7 11.7
Additional Charge kg data book
Sound Pressure dBA 54 57 58 60 60 60
Piping Limits Maximum Length m 150
Maximum Vertical Rise m 50
Piping Connections Liquid inches 3/8 3/8 3/8 1/2 1/2 1/2
Gas inches 5/8 3/4 7/8 1 1/8 1 1/8 1 1/8
Capacity Index Limit 62.5~162.5 100~260 125~325 150~390 175~455 200~520
Maximum Number of Connected Indoor Units 10 17 21 26 30 34
Trade Condensing Unit Price 4,254.00 5,344.00 5,840.00 7,150.00 8,342.00 9,628.00
VRVIII-Q Condensing Unit Heat Pump
RQYQ-P (up to 16 HP)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Outdoor Units RQYQ18P RQYQ20P RQYQ22P RQYQ24P
RQYQ8P RQYQ10P RQYQ8P RQYQ12P RQYQ10P RQYQ12P RQYQ12P RQYQ12P
Capacity Nominal Cooling kW 50.40 55.90 61.50 67.00
Nominal Heating kW 56.50 62.50 69.00 75.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 930 930 930 930 930 930 930 930
Depth mm 765 765 765 765 765 765 765 765
Weight kg 230 284 230 284 284 284 284 284
Air Flow Rate m
3
/sec 3.00 3.08 3.00 3.33 3.08 3.33 3.33 3.33
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 21.1 23.8 27.1 29.8
Starting Current amps 78.0 79.0 88.0 88.0
Fuse Rating amps 25 25 25 25 25 25 25 25
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.8 11.7 10.8 11.7 11.7 11.7 11.7 11.7
Additional Charge kg data book
Sound Pressure dBA 57 58 57 60 58 60 60 60
Piping Limits Maximum Length m 150
Maximum Vertical Rise m 50
Piping Connections Liquid inches 5/8 5/8 5/8 5/8
Gas inches 1 1/8 1 1/8 1 1/8 1 3/8
Discharge inches - -
Oil Equalising inches - -
Capacity Index Limit 225~585 250~650 275~715 300~780
Maximum Number of Connected Indoor Units 39 43 47 52
Trade Condensing Unit Price 11,184.00 12,494.00 12,990.00 14,300.00
VRVIII-Q Condensing Unit Heat Pump
RQYQ-P (18 to 24 HP)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Integrated Solutions
V
R
V

70
Outdoor Units RQYQ26P RQYQ28P RQYQ30P RQYQ32P
RQYQ10P RQYQ16P RQYQ12P RQYQ16P RQYQ14P RQYQ16P RQYQ16P RQYQ16P
Capacity Nominal Cooling kW 73.00 78.50 84.00 90.00
Nominal Heating kW 81.50 87.50 94.50 100.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 930 1240 930 1240 1240 1240 1240 1240
Depth mm 765 765 765 765 765 765 765 765
Weight kg 284 381 284 381 381 381 381 381
Air Flow Rate m
3
/sec 3.08 3.88 3.33 3.88 3.88 3.88 3.88 3.88
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 34.7 37.4 42.1 45.0
Starting Current amps 98.0 98.0 108.0 109.0
Fuse Rating amps 25 35 25 35 35 35 35 35
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7
Additional Charge kg data book
Sound Pressure dBA 58 60 60 60 60 60 60 60
Piping Limits Maximum Length m 150
Maximum Vertical Rise m 50
Piping Connections Liquid inches 3/4 3/4 3/4 3/4
Gas inches 1 3/8 1 3/8 1 3/8 1 3/8
Discharge inches - -
Oil Equalising inches - -
Capacity Index Limit 325~845 350~910 375~975 400~1040
Maximum Number of Connected Indoor Units 56 60 64 64
Trade Condensing Unit Price 15,468.00 16,778.00 17,970.00 19,256.00
VRVIII-Q Condensing Unit Heat Pump
RQYQ-P (26 to 32 HP)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Outdoor Units RQYQ34P RQYQ36P RQYQ38P
RQYQ10P RQYQ10P RQYQ14P RQYQ10P RQYQ10P RQYQ16P RQYQ10P RQYQ12P RQYQ16P
Capacity Nominal Cooling kW 96.00 101.00 107.00
Nominal Heating kW 108.00 113.00 119.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 930 930 1240 930 930 1240 930 930 1240
Depth mm 765 765 765 765 765 765 765 765 765
Weight kg 284 284 381 284 284 381 284 284 381
Air Flow Rate m
3
/min 185 185 233 185 185 233 185 200 233
External Static Pressure High Pa 78 78 78
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 44.0 49.6 49.6
Starting Current amps 110 111 111
Fuse Rating amps 25 25 35 25 25 35 25 25 35
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7
Additional Charge kg data book
Sound Pressure dBA 58 58 60 58 58 60 58 60 60
Piping Limits Maximum Length m 150
Maximum Vertical Rise m 50
Piping Connections Liquid inches 3/4 3/4 3/4
Gas inches 1 3/8 1 5/8 1 5/8
Capacity Index Limit 425~1105 450~1170 475~1235
Maximum Number of Connected Indoor Units 64 64 64
Trade Condensing Unit Price 20,022.00 21,308.00 22,618.00
VRVIII-Q Condensing Unit Heat Pump
RQYQ-P (34 to 38 HP)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Price List 2013 71
V
R
V

Outdoor Units RQYQ40P RQYQ42P RQYQ44P


RQYQ12P RQYQ12P RQYQ16P RQYQ10P RQYQ16P RQYQ16P RQYQ12P RQYQ16P RQYQ16P
Capacity Nominal Cooling kW 112.00 118.00 124.00
Nominal Heating kW 125.00 132.00 138.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 930 930 1240 930 1240 1240 930 1240 1240
Depth mm 765 765 765 765 765 765 765 765 765
Weight kg 284 284 381 284 381 381 284 381 381
Air Flow Rate m
3
/min 200 200 233 185 233 233 200 233 233
External Static Pressure High Pa 78 78 78
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 52.3 57.2 59.9
Starting Current amps 111 122 122
Fuse Rating amps 25 25 35 25 35 35 25 35 35
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7 11.7
Additional Charge kg data book
Sound Pressure dBA 60 60 60 58 60 60 60 60 60
Piping Limits Maximum Length m 150
Maximum Vertical Rise m 50
Piping Connections Liquid inches 3/4 3/4 3/4
Gas inches 1 5/8 1 5/8 1 5/8
Capacity Index Limit 500~1300 525~1365 550~1430
Maximum Number of Connected Indoor Units 64 64 64
Trade Condensing Unit Price 23,928.00 25,096.00 26,406.00
VRVIII-Q Condensing Unit Heat Pump
RQYQ-P (40 to 44 HP)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Outdoor Units RQYQ46P RQYQ48P
RQYQ14P RQYQ16P RQYQ16P RQYQ16P RQYQ16P RQYQ16P
Capacity Nominal Cooling kW 130.00 135.00
Nominal Heating kW 145.00 150.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680
Width mm 1240 1240 1240 1240 1240 1240
Depth mm 765 765 765 765 765 765
Weight kg 381 381 381 381 381 381
Air Flow Rate m
3
/min 233 233 233 233 233 233
External Static Pressure High Pa 78 78
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 64.6 67.5
Starting Current amps 132 134
Fuse Rating amps 35 35 35 35 35 35
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 11.7 11.7 11.7 11.7 11.7 11.7
Additional Charge kg data book
Sound Pressure dBA 60 60 60 60 60 60
Piping Limits Maximum Length m 150
Maximum Vertical Rise m 50
Piping Connections Liquid inches 3/4 3/4
Gas inches 1 5/8 1 5/8
Capacity Index Limit 575~1495 600~1560
Maximum Number of Connected Indoor Units 64 64
Trade Condensing Unit Price 27,598.00 28,884.00
VRVIII-Q Condensing Unit Heat Pump
RQYQ-P (46 to 48 HP)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Integrated Solutions
V
R
V

72
Outdoor Units RQCEQ280P RQCEQ360P RQCEQ460P
RQEQ140P RQEQ140P RQEQ180P RQEQ180P RQEQ140P RQEQ140P RQEQ180P
Capacity Nominal Cooling kW 28.00 36.00 45.00
Nominal Heating kW 32.00 40.00 52.00
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680
Width mm 635 635 635 635 635 635 635
Depth mm 765 765 765 765 765 765 765
Weight kg 175 175 175 175 175 175 175
Air Flow Rate m
3
/sec 1.58 1.58 1.58 1.58 1.58 1.58 1.58
External Static Pressure High Pa 78 78 78
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 5.5+5.5 8.0+8.0 5.5+5.5+8.0
Starting Current amps 4 4 4
Fuse Rating amps 15 15 20 20 15 15 20
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.3 10.3 10.6 10.6 10.3 10.3 10.6
Additional Charge kg data book
Sound Pressure dBA 54 54 58 58 54 54 58
Piping Limits Maximum Length m 120 120 120
Maximum Vertical Rise m 50
Piping Connections Liquid inches 3/8 1/2 1/2
Gas inches 7/8 1 1 1/8
Capacity Index Limit 125~325 162.5~422.5 200~520
Maximum Number of Connected Indoor Units 16 20 26
Trade Condensing Unit Price 6,442.00 8,284.00 10,584.00
VRVIII-Q Condensing Unit Heat Recovery
RQCEQ-P (28.0 to 45.0 kW)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Outdoor Units RQCEQ500P RQCEQ540P RQCEQ636P
RQEQ140P RQEQ180P RQEQ180P RQEQ180P RQEQ180P RQEQ180P RQEQ212P RQEQ212P RQEQ212P
Capacity Nominal Cooling kW 50.00 54.00 63.60
Nominal Heating kW 56.00 60.00 67.20
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 635 635 635 635 635 635 635 635 635
Depth mm 765 765 765 765 765 765 765 765 765
Weight kg 175 175 175 175 175 175 179 179 179
Air Flow Rate m
3
/sec 1.58 1.58 1.58 1.58 1.58 1.58 1.83 1.83 1.83
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 5.5+8.0+8.0 8.0+8.0+8.0 11.5+11.5+11.5
Starting Current amps 4 4 4
Fuse Rating amps 15 20 20 20 20 20 20 20 20
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10 11 11 11 11 11 11 11 11
Additional Charge kg data book
Sound Pressure dBA 54 58 58 58 58 58 60 60 60
Piping Limits Maximum Length m 120
Maximum Vertical Rise m 50
Piping Connections Liquid inches 5/8 5/8 5/8
Gas inches 1 1/8 1 1/8 1 1/8
Discharge inches 7/8 7/8 1
Oil Equalising inches - - -
Capacity Index Limit 225~585 250~650 275~715
Maximum Number of Connected Indoor Units 29 33 36
Trade Condensing Unit Price 11,505.00 12,426.00 14,643.00
VRVIII-Q Condensing Unit Heat Recovery
RQCEQ-P (50.0 to 63.6 kW)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Price List 2013 73
V
R
V

Outdoor Units RQCEQ712P RQCEQ744P


RQEQ140P RQEQ180P RQEQ180P RQEQ212P RQEQ140P RQEQ180P RQEQ212P RQEQ212P
Capacity Nominal Cooling kW 71.20 74.40
Nominal Heating kW 78.40 80.80
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 635 635 635 635 635 635 635 635
Depth mm 765 765 765 765 765 765 765 765
Weight kg 175 175 175 179 175 175 179 179
Air Flow Rate m
3
/sec 1.58 1.58 1.58 1.83 1.58 1.58 1.83 1.83
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 5.5+8.0+8.0+11.5 5.5+8.0+11.5+11.5
Starting Current amps 4 4
Fuse Rating amps 15 20 20 20 15 20 20 20
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.3 10.6 10.6 11.2 10.3 10.6 11.2 11.2
Additional Charge kg data book
Sound Pressure dBA 54 58 58 60 54 58 60 60
Piping Limits Maximum Length m 120
Maximum Vertical Rise m 50
Piping Connections Liquid inches 5/8 3/4
Gas inches 1 1/8 1 3/8
Discharge inches 1 1
Oil Equalising inches - -
Capacity Index Limit 300~780 325~845
Maximum Number of Connected Indoor Units 40 43
Trade Condensing Unit Price 16,386.00 17,125.00
VRVIII-Q Condensing Unit Heat Recovery
RQCEQ-P (71.2 to 74.4 kW)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Outdoor Units RQCEQ816P RQCEQ848P
RQEQ180P RQEQ212P RQEQ212P RQEQ212P RQEQ212P RQEQ212P RQEQ212P RQEQ212P
Capacity Nominal Cooling kW 81.60 84.80
Nominal Heating kW 87.20 89.60
Dimensions Height mm 1680 1680 1680 1680 1680 1680 1680 1680
Width mm 635 635 635 635 635 635 635 635
Depth mm 765 765 765 765 765 765 765 765
Weight kg 175 179 179 179 179 179 179 179
Air Flow Rate m
3
/sec 1.58 1.83 1.83 1.83 1.83 1.83 1.83 1.83
Electrical Details Power Supply Phase 3ph
Hz 50
V 400
Running Current amps 8.0+11.5+11.5+11.5 11.5+11.5+11.5+11.5
Starting Current amps 4 4
Fuse Rating amps 20 20 20 20 20 20 20 20
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.6 11.2 11.2 11.2 11.2 11.2 11.2 11.2
Additional Charge kg data book
Sound Pressure dBA 58 60 60 60 60 60 60 60
Piping Limits Maximum Length m 120
Maximum Vertical Rise m 50
Piping Connections Liquid inches 3/4 3/4
Gas inches 1 3/8 1 3/8
Discharge inches 1 1/8 1 1/8
Oil Equalising inches - -
Capacity Index Limit 350~910 375~975
Maximum Number of Connected Indoor Units 47 50
Trade Condensing Unit Price 18,785.00 19,524.00
VRVIII-Q Condensing Unit Heat Recovery
RQCEQ-P (81.6 to 84.8 kW)
Please see note on page 74 regarding VRVIII-Q warranty, and contact your local sales ofce for more information on VRVIII-Q installation.
Integrated Solutions
V
R
V

74
VRVIII-Q Warranty
Warranty and Site Services
The warranty for VRVIII-Q systems operates under diferent conditions to
our standard warranty. To ensure complete suitability of the existing site,
a choice of optional warranty and special site services packages are
available from Daikin Airconditioning UK Ltd. These choices will ensure the
VRVIII-Q system is designed and commissioned to provide the client with
complete peace of mind operation.
The choices include:
a) Pre-order checks on the existing pipework and fan coils installed on the
clients site to ensure suitability for VRVIII-Q installation
b) Commissioning of the new VRVIII-Q installation to ensure correct and
ecient operation
c) DNSS EcoSave remote diagnostics and preventative monitoring system
Warranty options for 3 or 5 years are available depending on the
combination of choices chosen, and the condition that equipment is
installed and commissioned by an engineer trained and approved for VRV
equipment by Daikin Airconditioning UK Ltd.
Commissioning Log Books will need to be submitted to Daikin
Airconditioning UK Ltd to activate the warranty.
The tables below provide an overview of the choices, with a brief description
on page 75. For full details please contact your local sales oce.
Warranty Package Level For Site with Existing Fan Coils
Standard Silver Gold
Condensing Unit Warranty Period 3 Years 3 Years 5 Years
Fan Coil Unit Warranty Period 0 Years 1 Year 1 Year
Site Pre-Order
Inspection
By Approved Engineer - - -
By Daikin Airconditioning UK Ltd 3 3 3
Commissioning By Approved Engineer 3 - -
By Daikin Airconditioning UK Ltd Additional Cost Option 3 3
DNSS Daikin DNSS EcoSave Monitoring - 3 3
Net Price Price per complete System
for full warranty period
8-13HP 175 1,130 1,500
16-22HP 175 1,280 1,750
24-30HP 175 1,430 2,000
Order Code 8-13HP UK.FSVQ/E/STAND UK.FSVQ/E/SV/8-13 UK.FSVQ/E/GD/8-13
16-22HP UK.FSVQ/E/STAND UK.FSVQ/E/SV/16-22 UK.FSVQ/E/GD/16-22
24-30HP UK.FSVQ/E/STAND UK.FSVQ/E/SV/24-30 UK.FSVQ/E/GD/24-30
Warranty Package Level For Site with New Fan Coils
Standard Silver Gold
Condensing Unit Warranty Period 3 Years 5 Years 5 Years
Fan Coil Unit Warranty Period 3 Years 5 Years 5 Years
Site Pre-Order
Inspection
By Approved Engineer 3 3 3
By Daikin Airconditioning UK Ltd Additional Cost Option Additional Cost Option Additional Cost Option
Commissioning By Approved Engineer 3 - -
By Daikin Airconditioning UK Ltd - 3 3
DNSS Daikin DNSS EcoSave Monitoring - - 3
Net Price Price per complete System
for full warranty period
8-13HP 0 400 1,325
16-22HP 0 400 1,575
24-30HP 0 400 1,825
Order Code 8-13HP UK.FSVQ/N/STAND UK.FSVQ/N/SV/8-13 UK.FSVQ/N/GD/8-13
16-22HP UK.FSVQ/N/STAND UK.FSVQ/N/SV/16-22 UK.FSVQ/N/GD/16-22
24-30HP UK.FSVQ/N/STAND UK.FSVQ/N/SV/24-30 UK.FSVQ/N/GD/24-30
VRVIII-Q Warranty Choices
Notes:
i) All prices shown are Net. No further discount can be applied.
1. VRVIII-Q combined with existing fan coil units
2. VRVIII-Q combined with new fan coil units
Price List 2013 75
V
R
V

Approved engineer
An approved engineer is an engineer who:
1. Is suitably registered in accordance with F-gas regulations;
2. Has successfully completed a Daikin Airconditioning UK Ltd VRVIII Air Cooled
installation and commissioning course within the last 3 years.
Net price
Net price, exclusive of VAT and subject to our standard terms and conditions.
No other discounts are applicable.
Prices shown for site pre-order inspection and commissioning are for work
undertaken during normal working hours between 09:00 and 17:30. Any requests
for attendance to site out of these hours is subject to additional charges.
Warranty
To activate the warranty the Daikin Airconditioning UK Ltd VRV Commissioning
Log Book will need to be fully completed and submitted to Daikin Airconditioning
UK Ltd FQS department for checking. Upon receipt and validation that all required
details are provided and satisfactory, Daikin Airconditioning UK Ltd will issue a
conrmation letter that the warranty is activated. Where Daikin Airconditioning UK
Ltd will complete the commissioning we will provide a copy of the Commissioning
Log Book to the installation contractor. Except where mentioned above, our
standard warranty conditions will apply. If none of the packaged options are
chosen, then the warranty will be limited to a standard 12 month parts only cover.
Site pre-order inspection
Where included in the package, Daikin Airconditioning UK Ltd will attend the site
to check the suitability of the existing equipment and pipework for connection
to VRV-IIIQ. Where it is not possible to check operation or equipment condition,
this will also be highlighted in the nal report, and appropriate recommendations
made.
If an approved engineer carries out the site inspection, then a Daikin
Airconditioning UK Ltd supplied form shall be completed and submitted to our
FQS department for checking and approval prior to any order being accepted.
The pre-order site inspection will include for the following items.
Existing system(s) capacity necessary to estimate required system load for
the new system
Record all the model numbers and the serial numbers for the indoor and the
outdoor units and indicate actual installed system combinations
Check status of the existing indoor units necessary if the existing units are
to be reused
Check flter condition
Check coil condition
Check fan motor operation select fan only and check for air movement and
for unusual noise and vibration
Installed pipework details necessary to check compliance with the
manufacturers specication and assess install quality. This would highlight any
required rectication prior to the installation of the new system
Provide as installed pipework diagrams. If not available, provide as installed
pipe work schematics from information gathered on site
Check the distance from the outdoor to the farthest indoor along the pipe
work route
Check the distance from the frst Refnet ftting to the farthest indoor unit
Check the height diference between the outdoor and the lowest indoor
when the outdoor is situated above the indoor units or height dierence
between the outdoor and the highest indoor if the outdoor is situated below
the indoor units
Check the height diference between the highest and the lowest indoor
connected to the same system
Provide the lengths of all installed pipe sizes
Check the installation position and angle of the Refnet Joints
Check the condition of the pipe insulation
Check the adequacy of the existing pipe supports
Installed communication and control wiring necessary to check
compliance with the manufacturers specication, suitability for the new system
and suitability for new controls specication
Check sizes and type of the interconnecting communication cables between
indoor units, outdoor units and any central control systems
Check the separation between the power wiring and the installed
controls wiring
Power wiring to the outdoor units necessary to check suitability for the new
outdoor units
Check supply voltage
Check number of outlets available adjacent to the outdoor units compound.
Check fuse/MCB sizes and types
Check status of the isolators
VRVIII-Q Warranty Detail
Integrated Solutions
V
R
V

76
System health check it is important to know if the existing systems are
operating to their optimum. If there are issues which may aect the new
installation they need to identied and rectied before installation of the
new system. A comprehensive list of the operating data can be collected
by connecting a VRV Checker to each system and recording a minimum of
one hour operation data for analysis. This data should be sent back to Daikin
Airconditioning UK Ltd FQS department for analysis
Operate the whole system in cooling for hour and in heating for hour to
collect representative data
Send data to Daikin Airconditioning UK Ltd FQS department for analysis
System history check although the new VRV-IIIQ system is designed to
re-use existing pipework and in some cases existing indoor units it is still
necessary to know the existing systems operational history to judge its integrity
for the new application
Check for presence of leak protection dye and acid level use total test kit
Ensure that no Acid Away chemical has ever been added to the system
refrigerant charge
Existing system controls investigate currently installed local controls,
centralised controls and connection to the third party systems. This is
particularly necessary if any existing controls are planned to be re-used
Commissioning
Dependant on the warranty package chosen, either an approved engineer
or Daikin Airconditioning UK Ltd will provide system commissioning on the
completed installation. As mentioned in the warranty section above, a completed
log book will need to be submitted to activate the warranty
Commissioning where not provided by Daikin Airconditioning UK Ltd, can
only be completed by an approved engineer
Where Daikin Airconditioning UK Ltd provide commissioning as part of the
package this shall include:
Check installation of new units ensure new piping is installed correct to
Daikin specication
Check power supplies local isolators, MCB rating
Fill in model number data, serial numbers etc to commissioning log book;
Initialise VRV System and ensure all units communicate
Set up additional control systems ITC, Bacnet and provide demonstration
Charge additional refrigerant
Perform Test operation including Automatic charging function
Connect service checker and monitor operation Cool>Heat>Heat Recovery
Complete Commissioning Log Book
Provide additional comments and recommendations if necessary
Leave operation set as required by client
Prior to our site attendance the following shall be completed:
All communication wiring is complete and terminated correctly
All electrical work is complete and correct (supply wiring type and size
breaker size correct)
All systems piping has been pressure tested to 33 Bar
All systems piping is evacuated to < 5 Torr
All systems piping has been measured and is available for our information
Sufcient additional refrigerant is available on the day
Any other works other than those detailed above are excluded.
DNSS (Daikin Network Service System)
Where Daikin Airconditioning UK Ltd provide DNSS as part of the package
this shall include the following items:
Commissioning of DNSS system (on site service)
GPRS router and SIM (this will be property of Daikin Airconditioning UK Ltd)
Remote energy saving service
24/7 monitoring of VRV operating data
Instant notifcation of system malfunction (email) 7 days a week
Malfunction prediction service (during ofce hours 09.00 -17.30)
Bi-annual energy saving report indicating electricity cost saving and reduction
in CO
2
emissions
Recommendations to improve operating settings
Issue of a DNSS user pack
All of the above will be provided for the warranty period of the VRV (either 3 or 5
years) depending on the package selected.
Prior to our site attendance the following shall be completed:
A device compatible with DNSS is installed on site Daikin Intelligent Manager,
Daikin Intelligent Touch Controller or Daikin LC controller. (Not included in the
price of the monitoring package)
All electrical work is complete and correct (supply wiring type and size
breaker size correct) also F1/F2 communications are installed
A full set of as installed drawings are available indicating system
congurations, installation locations and room references
A power source is installed for the GPRS modem near the control device
this can be powered from a standard socket
A connection to the internet is available for areas where there is poor GPRS
coverage a LAN or analogue phone connection must be installed near the
control device. (Installation and rental costs are not included in the price of the
monitoring package)
Full access must be made available to the VRV equipment and if any access
equipment is required Daikin UK must be informed prior to the site visit
A list of contacts must be issued to Daikin Airconditioning UK Ltd (these
are the contacts that should be e-mailed or telephoned in the event of a
malfunction or error with the air conditioning system). If these change in
the future, information will be given in the user pack for how to notify Daikin
Airconditioning UK Ltd of the changes
This is an extract from the Daikin publication Warranty and Site Services Package
for VRV-IIIQ. Please contact your local sales ofce to receive a copy and obtain
further information.
VRVIII-Q Warranty Detail
Price List 2013 77
V
R
V

VRV Accessories
Integrated Solutions
V
R
V

78
Outdoor Units Single Boxes Multi Boxes
BSVQ100P8B BSVQ160P8B BSVQ250P8B BSV4Q100PV BSV6Q100PV
Dimensions Height mm 207 209
Width mm 388 1050 1577
Depth mm 326 635
Weight kg 14 14 15 60 87
Total Indoor Capacity 20 ~ 100 20 ~ 160 161 ~ 250 (4 no) 20-100 (6 no) 20-100
Number of Fan Coil Units 5 8 8 4-20 * 6-30 **
Electrical Details Power Supply Phase 1
Hz 50
V 230
Running Current amps 0.1 0.1 0.1 TBA TBA
Fuse Rating amps 5 5 5 TBA TBA
Piping Limits Level Diference m data book
Maximum Length m
Piping Connections
Indoor
Liquid inches 3/8 3/8 3/8 3/8 3/8
Gas inches 5/8 5/8 7/8 5/8 5/8
Piping Connections
Outdoor
Liquid inches 3/8 3/8 3/8 1/2 5/8
Suction inches 5/8 5/8 7/8 3/4 1 1/8
Discharge inches 1/2 1/2 3/4 1 1/8 1 1/8
Trade Accessory price 330.00 364.00 418.00 1,317.00 2,002.00
* BSV4Q100PV MUST have the minimum of one indoor unit connected to at least 3 of the 4 no outlets
** BSV6Q100PV MUST have the minimum of one indoor unit connected to at least 5 of the 6 no outlets
VRVIII Heat Recovery
Branch Selector Boxes BSVQ
For Outdoor Units 2-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units RXYSQ / RYYQ / RWEYQ / EMRQ Trade Price
Total Capacity of
Indoor Units
Liquid
Pipe
Suction
Pipe
Refnet
Selection
RXYQ5P/
RXYSQ4-6PA
Below 62.5 1/4 1/2 KHRQ22M20T 28.00
62.5 to 162.5 3/8 5/8 KHRQ22M20T 28.00
RYYQ8-54T/
EMRQ8AA-16AA
Below 150 3/8 5/8 KHRQ22M20T 28.00
150 to below 200 3/8 3/4 KHRQ22M20T 28.00
200 to below 290 3/8 7/8 KHRQ22M29T9 35.00
290 to below 420 1/2 1 1/8 KHRQ22M64T 37.00
420 to 639 5/8 1 1/8 KHRQ22M64T 37.00
640 and above Please contact your local sales ofce for selection KHRQ22M75T 47.00
Refnet Header KHRQ22M29H 111.00
Refnet Header KHRQ22M64H 136.00
Refnet Header KHRQ22M75H 178.00
Condensing Unit Branch Kit - 2 Module RYYQ, RWEYQ BHFQ22P1007 76.00
Condensing Unit Branch Kit - 3 Module RYYQ BHFQ22P1517 150.00
Condensing Unit Branch Kit - 2 Module RQYQ BHFP22P36C 94.00
Condensing Unit Branch Kit - 3 Module RQYQ BHFP22P54C 187.00
For Outdoor Units 3-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units REYQ / RWEYQ / EMRQ Trade Price
Total Capacity of
Indoor Units
Liquid
Pipe
Discharge
Pipe
Suction
Pipe
Refnet
Selection
REY(H)Q8-24P/
REYQ8-48P8/P9/
RWEYQ8-30P/
EMRQ8AA-16AA
Below 150 3/8 1/2 5/8 KHRQ23M20T 41.00
150 to below 200 3/8 5/8 3/4 KHRQ23M20T 41.00
200 to below 290 3/8 3/4 7/8 KHRQ23M29T9 53.00
290 to below 420 1/2 3/4 1 1/8 KHRQ23M64T 56.00
420 to 639 5/8 1 1/8 1 1/8 KHRQ23M64T 56.00
640 and above Please contact your local sales ofce for selection KHRQ23M75T 70.00
Refnet Header KHRQ23M29H 153.00
Refnet Header KHRQ23M64H 186.00
Refnet Header KHRQ23M75H 261.00
Condensing Unit Branch Kit - 2 Module REYQ, RWEYQ BHFQ23P907 142.00
Condensing Unit Branch Kit - 3 Module REYQ, RWEYQ BHFQ23P1357 287.00
Condensing Unit Branch Kit - 2 Module RQEQ BHFP26P36C 160.00
Condensing Unit Branch Kit - 3 Module RQEQ BHFP26P63C 326.00
Condensing Unit Branch Kit - 4 Module RQEQ BHFP26P84C 433.00
VRV Condensing Unit Refnet Joints
Price List 2013 79
V
R
V

VRV Accessories Remote Controllers (supplied loose)


VRV Remote Control
Options
Model Description Related Fan Coil Trade Price
BRC1E52 A / B
Premium wired remote controller with full text menu,
Energy features and 7 Day Time Clock
All 74.00
BRC2C51 Wired Simplifed remote controller (without auto swing) All 88.00
KJB111A
Recessed Fixing box for BRC2C51
(not required for UK.BRC2C Brass or Chrome Models)
All 16.00
UK.BRC2C/CHROME/POL
BRC2C51 with Polished Chrome Facia
without Heat /Cool mode switch
All 161.00
UK.BRC2C/CHR/POL/HC
BRC2C51 with Polished Chrome Facia
with Heat / Cool switch
All 167.00
UK.BRC2C/CHROME/BRU
BRC2C51 with Brushed Chrome Facia
without Heat / Cool mode switch
All 161.00
UK.BRC2C/CHR/BRU/HC
BRC2C51 with Brushed Chrome Facia
with Heat / Cool switch
All 167.00
UK.BRC2C/BRASS/POL
BRC2C51 with Polished Brass Facia
without Heat / Cool mode switch
All 161.00
UK.BRC2C/BRA/POL/HC
BRC2C51 with Polished Brass Facia
with Heat / Cool switch
All 167.00
BRC4C61 Wireless remote controller FXKQ 132.00
BRC4C62 Wireless remote controller FXDQ-M9, FXMQ-MA 132.00
BRC4C65 Wireless remote controller FXDQ-A, FXSQ, FXMQ-P, FXLQ, FXNQ 149.00
BRC7C58 Wireless remote controller FUQ, FXUQ 149.00
BRC7C52 Wireless remote controller FXCQ 149.00
BRC7E618 Wireless remote controller FXAQ 132.00
BRC7F530W Wireless remote controller for White Ceiling Decoration Panel FXZQ-A + BYFQ60CW 149.00
BRC7F530S Wireless remote controller for Silver Ceiling Decoration Panel FXZQ-A + BYFQ60CS 149.00
BRC7FA532F Wireless remote controller FXFQ-A 149.00
BRC7G53 Wireless remote controller FXHQ 149.00
Integrated Solutions
V
R
V

80
VRV Accessories Control and BMS Interfaces (supplied loose)
VRV Control and BMS Interfaces
KRP2A52 KRP4A53 RTD-NET RTD-10 RTD-HO KLIC-DI DMS504B51 DMS502A51
Interface Method System Unit/Group
Control Protocol - - Modbus Modbus - Modbus KNX LONWorks BACnet
0-10 Volt control
4 4
- -
4
- - - -
Resistance control
4 4
- -
4
- - - -
Control Functions
On/Of
4 4 4 4 4 4 4 4 4
SetPoint
4 4 4 4 4 4 4 4 4
Operating Mode
4 4 4 4 4 4 4 4 4
Fan Speed
4 4 4 4 4 4 4 4 4
Louver Setting - -
4 4 4 4 4
-
4
VAM Damper control - -
4 4 4
- - - -
Control Prohibit / Restrict settings - -
4 4 4 4
-
4 4
Temperature SetPoint Limits - -
4 4
-
4 4
- -
Scene Creation - - - - - -
4
- -
Monitoring Functions
On/Of
4 4 4 4
-
4 4 4 4
Temperature Set Point - -
4 4
-
4 4 4 4
Operating Mode - -
4 4
-
4 4 4 4
Thermostat On - -
4 4 4 4
- -
4
Fan Operation - -
4 4
-
4 4
-
4
Louvre Position - -
4 4
-
4 4
-
4
Fault
4 4 4 4 4 4 4 4 4
Fault Code - -
4 4
-
4 4 4 4
Remote Controller temperature - -
4 4
-
4
-
4 4
Remote Controller Mode - -
4 4
-
4
- -
4
Number of Units - -
4 4
-
4
- - -
Return Air Temperature (Average/Min/Max) - -
4 4
-
4
-
4 4
Coil In/Out temperature - -
4 4
-
4
- - -
Filter Alarm - -
4 4
-
4 4 4 4
Defrost Operation - -
4 4 4 4
- - -
Integral Functions (BMS system not reqd)
Temperature Set Back - - - - -
4
- - -
Temperature Setpoint Limitation - - -
4 4 4
- - -
Key Card + Window Contact - - - - -
4
- - -
Heating Interlock - - -
4 4
- - - -
Run / Standby - - -
4 4
- - - -
Prices
Interface KRP2A52 KRP4A53 RTD-NET RTD-10 RTD-HO KLIC-DI DMS504B51 DMS502A51
Trade Price 173.00 65.00 161.00 205.00 POA 181.00 POA POA
Associated Items
Mounting Box
(FXFQ, FXCQ, FXZQ, FXUQ, FXHQ, FXDQ, FXAQ)
UK.FB2 UK.FB2 UK.FB2 UK.FB2 UK.FB2 - - -
Trade Price 24.00 24.00 24.00 24.00 24.00 - - -
Expansion PCB for additional unit connection - - - - - - - DAM411B51
Trade Price - - - - - - - POA
Price List 2013 81
V
R
V

VRV Accessories Centralised Control Solutions


Model Description Related Unit Trade Price
DCS601C51 Intelligent touch controller for up to 64 fan coil units
All units with F1, F2
wiring connection
1,608.00
KJB411A Recessed Fixing box for I-Touch controller DCS601C51 67.00
DCS007A51 HTTP Open Protocol Software for I-Touch controller DCS601C51 917.00
DCS302A52 Adaptor PCB for external on/of control of I-Touch controller and I-Touch Manager DCS601C51 101.00
DTA103A51 Adaptor PCB for on/of control of external device from I-Touch controller and I-Touch manager DCS601C51 299.00
UK.IC Confg I-Touch controller - of site confguration charge (please contact your sales ofce for info/prices) DCS601C51 POA
Integrated Solutions
V
R
V

82
VRV Accessories Centralised Control Solutions
Model Description Related Unit Trade Price
DCM601A51 I-Touch manager central touch screen controller, with integral web server and email function
All units with F1, F2
wiring connection
2,217.00
DCM601A52 I-Touch manager Expansion Module for up to 64 fan coil units and 4 x kWh Meters
All units with F1, F2
wiring connection
693.00
DCM601A53
I-Touch manager Integrator for single point access for up to 5 individual
I-Touch Managers controllers
DCM601A51 2,772.00
DCM002A51
Proportional Power Distribution add-on for I-Touch manager.
Provides ability for tenant billing
DCM601A51 POA
DCM008A51
Energy Navigator Software for I-Touch manager.
For on screen energy monitoring
DCM601A51 POA
DCS302A52 Adaptor PCB for external on/of control of I-Touch controller and I-Touch Manager DCS601C51 101.00
DTA103A51
Adaptor PCB for on/of control of external device from I-Touch controller
and I-Touch manager
DCS601C51 299.00
WAGO Interface
System
Modular interface system for connection to 3rd Party devices such as lights, pumps,
PIR sensors, access card readers, etc. Enables the iTM to control external devices and
provide customised interlocks for automation and energy saving logic
DCM601A51 POA
UK.IMAN/CONFIG1 I-Manager Of site confguration per FCU DCM601A51 POA
UK.IMAN/CONFIG2
I-Manager Of site confguration & graphical layout per FCU.
(Allow 4 weeks from order to delivery)
DCM601A51 POA
UK.FS1 On site commissioning for PPD or Energy Navigator Software DCM601A51 POA
UK.IMAN/SITE TRAIN On Site customer training for I Touch Manager System DCM601A51 POA
Price List 2013 83
V
R
V

VRV Accessories
Fan Coil Accessories (supplied loose)
Condensing Unit Accessories (supplied loose)
UK.RAC4
UK.SAF4
Model Description Related Unit Trade Price
BYCQ140CG Roundfow cassette decoration panel with self cleaning flter FXFQ-P 303.00
BYCQ140CW Roundfow cassette decoration panel - white with white louvres FXFQ-P 156.00
BYFQ60CW Fully fat cassette decoration panel in fresh white (N9.5) FXZQ-A 194.00
BYFQ60CS Fully fat cassette decoration panel in silver & white (B471 & N9.5) FXZQ-A 194.00
BYFQ60B2 600 Squ FXZQ-MA style decoration panel in pure white (RAL9010) FXZQ-A 139.00
KDBHQ55B140 Sealing member for air discharge outlet FXFQ-A 88.00
KDDQ55B140 1/2 Fresh air intake kit for up to 20% fresh air (not compatible with self cleaning deco-panel) FXFQ-A, FCQGH, FCQG 440.00
BYBS32D Return air suction grille FXSQ20~32 109.00
BYBS45D Return air suction grille FXSQ40~50, FBQ35~50 118.00
BYBS71D Return air suction grille FXSQ63~80, FBQ60~71 155.00
BYBS125D Return air suction grille FXSQ100~140, FBQ100~140 194.00
EKBYBSD Mounting Kit for Decoration Panel (when installed directly onto the unit body) FXSQ, FBQ 27.00
UK.RAC1 Return Air Chamber, 1 x 200mm dia FXSQ20-32P 68.00
UK.RAC2 Return Air Chamber, 2 x 200mm dia FXSQ40-50P, FBQ35-50C 77.00
UK.RAC3 Return Air Chamber, 2 x 200mm dia FXSQ63-80P, FBQ60-71C 84.00
UK.RAC3A Return Air Chamber, 3 x 200mm dia FXSQ63-80P, FBQ60-71C 91.00
UK.RAC4 Return Air Chamber, 4 x 200mm dia FXSQ100-125P, FBQ100-140C 113.00
UK.RAC5 Return Air Chamber, 2 x 150mm dia FXDQ20-32A TBC
UK.RAC6 Return Air Chamber, 3 x 150mm dia FXDQ40-50A TBC
UK.RAC7 Return Air Chamber, 4 x 150mm dia FXDQ63A TBC
UK.SAF1 Supply Air Flange 1 x 200mm dia FXSQ20-32P 61.00
UK.SAF2 Supply Air Flange 2 x 200mm dia FXSQ40-50P, FBQ35-50C 70.00
UK.SAF3 Supply Air Flange 2 x 200mm dia FXSQ63-80P, FBQ60-71C 77.00
UK.SAF3A Supply Air Flange 3 x 200mm dia FXSQ63-80P, FBQ60-71C 82.00
UK.SAF4 Supply Air Flange 4 x 200mm dia FXSQ100-125P, FBQ100-140C 101.00
UK.SAF5 Supply Air Flange 2 x 150mm dia FXDQ20-32A 65.00
UK.SAF6 Supply Air Flange 3 x 150mm dia FXDQ40-50A 71.00
UK.SAF7 Supply Air Flange 4 x 150mm dia FXDQ63A 83.00
UK.FF6P Filter frame and flter FXMQ40 to 80 98.00
UK.FF7P Filter frame and flter FXMQ100 to 125 115.00
UK.FF8 Filter frame and flter FXMQ200 to 250 143.00
KRCS01-4 Remote room mounted temperature sensor
FBQ, FCQG, FCQHG, FXFQ-P, FXZQ-A,
FXCQ-A, FXUQ-A, FXDQ-A, FXMQ-P,
FXSQ-P, FXHQ
46.00
KRCS01-1 Remote room mounted temperature sensor
FAQ, FHQG, FHQ, FFQ, FUQ, FXKQ,
FXDQ-M9, FXMQ-MA, FXAQ,
FXLQ, FXNQ
45.00
K.RSS Wireless room mounted temperature sensor and receiver All 91.00
RS-SE Service and Confguration Tool for K.RSS All 87.00
Model Description Related Unit Trade Price
BRP2A81 Adaptor PCB for Heat Cool selection terminals RYYQ 100.00
EKPCCAB1
VRV Confgurator Software Connection cable.
Software available from Daikin Extranet
RYYQ 182.00
UK.CGL Condensing Unit Guard Size 100 - 140 - suitable for RXYSQ 437.00
Strip & Rebuild of Condensing Units
VRV Condensing Units stripped down for delivery to site where lifting into position
is difcult with traditional methods. Units are rebuilt on site by Daikin UK Engineers
and fully tested
POA
Integrated Solutions
V
R
V

84
VRV Refrigerant Leak Detection Systems
Refrigerant leak detection systems can be required for a number of reasons.
These tend to fall into two categories.
1) Safety of Building Occupants as required by BS-EN378
2) Pollution prevention as detailed under BREEAM recommendations.
These two requirements require dierent approaches and Daikin UK can provide solutions for both situations.
Refrigerant Leak Detection Alarm
1) The standard BS-EN378 requires that systems containing R410a refrigerant gas such as VRV, meet the requirements regarding maximum system refrigerant
volumes that could leak within Hotel Bedroom or other similar Category Class A spaces. If these limitations are exceeded there must be an alarm system
installed within each room where this limit is not met. The alarm system must alert the occupier through both audible and visual indication, and must also alert
building sta such as supervisors, night porters etc. There is no specic requirement for the alarm system to be linked to the refrigerant system to pump down
or stop the operation, although this can be congured if required by the client.
Refrigerant Leak Pump Down System (Heat Recovery Only)
2) To reduce pollution potential through refrigerant leakage in the indoor distribution pipework and fan coil units, a system can be provided for installation on
Heat Recovery Systems. The system comprises a set of motorised isolation ball valves controlled through a central control panel that will instigate a refrigerant
pump down process, shut the isolation valves on main pipe line, and shut down the system on completion. The control panel will activate this function
following generation of a fault code from the VRV system indicating a loss of refrigerant. This system may be considered as suitable for BREEAM credits subject
to evaluation by the individual BREEAM assessor.
It is recommended that guidance on the
selection and installation of these systems is
obtained from your local Daikin UK sales ofce.
Example of System Components required for a Heat Recovery Outdoor Unit REYQ14P
1 x UK.MBVPAN 1,141.00
1 x 826.MBV01 440.00
1 x 826.MBV06 396.00
1 x 826.MBV08 579.00
System Total 2,556.00
Model Description Related Unit Trade Price
UK.MBVPAN
Central Control Panel providing automated refrigerant pump down and isolation of
condensing unit via motorised ball valves, (price excludes valves, see below)
REYQ, REMQ, REYAQ
1,141.00
UK.IAMC
Alarm buzzer and lamp panel for mounting in a central building supervisor location.
For connection to UK.MBVPAN
388.00
826.MBV01 3/8 + 1/2 Motorised Ball Valve c/w Aux Switch - Liquid 440.00
826.MBV02 5/8 Motorised Ball Valve c/w Aux Switch - Liquid 446.00
826.MBV03 3/4 Motorised Ball Valve c/w Aux Switch - Liquid 458.00
826.MBV04 7/8 Motorised Ball Valve c/w Aux Switch - Liquid 458.00
826.MBV05 5/8 Motorised Ball Valve - Gas 385.00
826.MBV06 3/4 Motorised Ball Valve - Gas 396.00
826.MBV07 7/8 Motorised Ball Valve - Gas 396.00
826.MBV08 1 1/8 Motorised Ball Valve - Gas 579.00
826.MBV09 1 3/8 Motorised Ball Valve - Gas 772.00
826.MBV10 1 5/8 Motorised Ball Valve - Gas 802.00
Model Description Related Unit Trade Price
UK.IAM1
Room based refrigerant gas detector with remote room mounted stainless steel facia
plate. Provides local audible and visual alarm notifcation. Terminals for connection
to alarm network and optional connection to VRV Fan coil to force system shut
down
All 279.00
UK.IAM2
Network alarm hub for connection of up to 16 room alarms. Hub can be connected
in a pyramid formation of 16 groups back to a single unit for connection to a central
alarm indicator panel (UK.IAMC)
All 550.00
UK.IAMC Alarm buzzer and lamp panel for mounting in a central building supervisor location All 388.00
Price List 2013 85
V
R
V

Extend product lifetime


The DNSS is designed to make sure that your equipment
is maintained and running as eciently as possible.
This optimisation will extend the lifespan of your equipment.
Malfunction messages
In the unlikely event of a problem occurring, your regional
Daikin UK oce will contact you directly. Our engineers, who
are dedicated to your installation, will inform you regarding the
nature of the problem and will help you towards the next step
of solving the problem.
Prevent product malfunctions
The DNSS will analyse the data from your equipment every
minute of the day and will alert us before the equipment actually
breaks down. In this way, failures can be prevented and possible
down time reduced to an absolute minimum.
Remote diagnostics
The DNSS continuously checks the cleanliness of the system
lters and heat exchanger. Furthermore, the DNSS manages a
wide range of data (pressures, temperatures, running hours, etc.)
in order to let your equipment run as eciently and trouble free
as possible. This will also prevent your equipment from using too
much energy.
E
N
E
R
G
Y

S
A
V
IN
G
S
U
P
T
O

2
5
%
U
N
IQ
U
E

IN
N
O
V
A
T
IO
N
B
Y

D
A
IK
IN
DNSS EcoSave
Your installation under continuous monitoring
24/7, 365 days a year remote monitoring
Predictive maintenance
Improved reliability
Improved comfort levels
Helps increase eciency
Helps reduce maintenance costs
Extends product lifetime
Extra value at low cost
A strategy of preventing breakdowns and limiting
unnecessary maintenance visits
Eciently organising site interventions by diagnosing the
nature and the extent of the problem before going to site
Innovative technology that helps to optimise your
equipments potential
Ensures the most comfortable environment in your
premises
The DNSS is a remote monitoring system, which
will allow you to continuously optimise the
running of your Daikin equipment; control your
energy consumption (so reduce your Carbon
Footprint), extend the life span of your equipment
and reduce operational costs.
What is the Daikin Network Service System (DNSS)?
V
R
V

86
87
V
e
n
t
i
l
a
t
i
o
n
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Ventilation
VAM / VKM 88
Integrated Solutions
V
e
n
t
i
l
a
t
i
o
n
88
With the advent of new building regulations, greater awareness of increasing energy costs and a
responsibility towards environmental issues, modern commercial spaces are insulated better than ever.
Ventilation
Double glazing, thicker insulation and draught exclusion of
course, help considerably towards reducing heating/cooling
demand and burdens on the environment.
The down-side however, is that these same commercial spaces
have now become, in eect, sealed boxes with little or no
replenishment of the air.
Daikin oers a variety of solutions for the provision of fresh air
ventilation to oces, hotels, stores and other commercial outlets.
Heat Reclaim Ventilation
Proper ventilation is a key component of climate control in
buildings, oces and shops. In its basic function, it ensures a
ow of incoming fresh air and outgoing stale air. Our HRV (heat
reclaim ventilation) solution can do much more. It can recover
heat and OPTIMISE THE BALANCE BETWEEN INDOOR AND
OUTDOOR TEMPERATURE AND HUMIDITY, thus reducing the
load on the system and increasing eciency.
Accessory Ref Description Trade Price
BRC1E52A Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock 74.00
KRP2A52/UK.FB2 System adaptor PCB for remote on/of, status indication and temperature setting 197.00
RTD-Net/UK.FB2 Modbus Interface PCB for Sky Air and VRV 185.00
RTD-20/UK.FB2 Energy control PCB for Sky Air and VRV. POA
Accessories: Notes:
i) Please contact your local sales ofce
for required options when combined
operation with an air conditioning system
is required
ii) Optional silencers, high efciency flters
etc are available. Prices and details on
request
iii) VKM models must be connected as
the slave indoor unit of a standard
VRV indoor unit and share the same
BRC1D52 remote controller and BSVQ unit
(If connected to Heat Recovery)
Total Heat Exchanger
VAM / VKM
VAM150FA VAM250FA VAM350FB VAM500FB VAM650FB VAM800FB VAM1000FB VAM1500FB VAM2000FB VKM50G VKM80G VKM100G
Dimensions Height mm 285 301 364 726 387
Width mm 776 828 1004 1514 1764
Depth mm 525 816 868 1156 868 1156 832 1214
Weight kg 24 33 52 64 131 152 96 109 114
Duct Connections mm 100 150 150 200 200 250 250 350 350 200 250 250
Air Flow Rate Ultra-High m
3
/hr 150 250 350 500 650 800 1000 1500 2000 500 750 950
High m
3
/hr 150 250 350 500 650 800 1000 1500 2000 500 750 950
Low m
3
/hr 110 155 230 350 500 670 870 1200 1400 440 640 820
External Static
Pressure
Ultra-High Pa 69 64 98 98 93 137 157 137 137 180 170 150
High Pa 39 39 150 120 100
Low Pa 20 20 110 80 70
Sound Pressure
Level (Heat
Exchange Mode)
Ultra-High dBA 28.5 29.0 32.0 33.0 34.5 36.0 36.0 39.5 40.0 39.0 41.5 41.0
High dBA 27.5 27.0 31.5 31.5 33.0 34.5 35.0 38.0 38.0 37.0 39.0 39.0
Low dBA 21.5 22.0 23.5 24.5 27.0 31.0 31.0 34.0 35.0 35.5 37.0 36.5
Electrical Details Power Supply V 230
Hz 50
Phase 1
Running Current A 0.9 0.9 0.9 1.3 1.6 2.5 3.0 5.0 5.0 3.8 3.8 3.8
Max Fuse Size A 15 15 15 15 15 15 15 15 15 15 15 15
Trade Unit Price 422.00 504.00 668.00 855.00 1,046.00 1,232.00 1,413.00 2,158.00 2,815.00 2,048.00 2,486.00 2,957.00
89
C
o
m
m
e
r
c
i
a
l

H
e
a
t
i
n
g
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Commercial Heating
Altherma Flex Product Overview 90
Altherma Flex De-centralised 91
Altherma Flex Centralised 92
Integrated Solutions
C
o
m
m
e
r
c
i
a
l

H
e
a
t
i
n
g
90
The Daikin Altherma Flex heat pump series is ideal for apartment buildings and community heating,
providing ecient air-to water heat pump technology for large residential and commercial buildings.
The Daikin Altherma Flex heat pump series
The product can be confgured either as a de-centralised
or a centralised system:
De-centralised system
The hydroboxes can be located in individual dwellings, such
as apartments or collective housing, to create a de-centralised
system. Each indoor unit can be operated independently,
providing each property with individual control of heating,
hot water (cooling optional on 50 & 80 class units).
The indoor hydrobox units are fully equipped with all the
required hydraulic components, so they can be connected easily
to the heat distribution system. Individual dwellings can also
be equipped with separate domestic hot water tanks, which are
designed to stack on top of the indoor units.
Centralised system
Alternatively, the indoor units can be
located together in one central plant area
to create a centralised system suitable
for a wide range of commercial and large
domestic applications.
The centralised indoor units oer modular
system scalability and capacity to meet the
heating demand of the overall building.
Price List 2013 91
C
o
m
m
e
r
c
i
a
l

H
e
a
t
i
n
g
Indoor Units (Hydrobox) EKHVMRD50A EKHVMRD80A EKHVMYD50A EKHVMYD80A
Function Heating & Hot water Heating, hot water & cooling
Heating Capacity kW 5.6 9 5.6 9
Cooling capacity kW n/a 5 8
Capacity Index 50 80 50 80
Dimensions HxWxD mm 705 x 600 x 695
Empty Weight kg 92 120
Leaving Water Temperature Range heating C 25~80
Leaving Water Temperature Range cooling C n/a 5~20
Drain valve Yes
Water Pump Nominal ESP Heating kPa 83.7 58.8
Expansion Vessel 7 litres heating 7 litres heating, 2 litres cooling
Material Precoated sheet metal
Colour Metalic Grey
Electrical Details Power Supply 230V 1ph 50Hz
Starting current amps 4
Nominal running Current* amps 6.5 10.9 6.5 10.9
Maximum running current amps 16.5
Fuse Rating amps 20
Refrigerant Pipe Sizes mm 12.7 Gas, 9.52 Liquid 12.7 Gas, 9.52 Liquid, 15.9 Suction
Water Side Pipe Sizes 1" Female
Sound Pressure Level dBA 40 42 40 42
Refrigerant R134a Cascade
Trade Unit Price Hydro Box 2,479.00 2,560.00 3,045.00 3,135.00
* Nominal running current stated at -3C ambient air temperature & 75C leaving water temperature 100% connection ratio
Domestic hot water cylinder EKHTSU200AC EKHTSU260AC
Type Unvented System (Includes EKUHWHT unvented Kit)
Water Volume l 200 260
Max Water Temperature C 75
Height mm 1335 1610
Width mm 600
Depth mm 695
Empty Weight kg 70 78
Colour Metallic grey
Material Inside Tank Stainless Steel
Material Outside Casing Precoated sheet metal
Piping Connections All inch 3/4 "
Insulation mm 80
Heat loss / 24hour dt 45C 1.2 1.5
Heat exchanger surface area m
2
1.56
Trade Unit Price 1,113.00 1,261.00
Altherma Flex Communal Heat Pump De-centralised
Daikin Altherma Flex type is the rst heating system for apartments and collective housing that fully
incorporates the use of renewable energy sources, making large residential buildings more environmentally
sustainable by reducing primary energy usage thus delivering lower running costs and CO
2
emissions.
Outdoor Units EMRQ8A EMRQ10A EMRQ12A EMRQ14A EMRQ16A
Capacity Nominal Heating kW 22.4 28.0 33.6 39.2 44.8
Dimensions Height x Width x Depth mm 1680 x 1300 x 765
Weight kg 331 339
Air Flow Rate m
3
/min 190 190 210 235 240
External Static Pressure High Pa 78.4 78.4 78.4 78.4 78.4
Electrical Details Power Supply 400 V 3ph 50 Hz
Starting current amps 74 74 75 4 4
Nominal running Current* amps 7.6 9.9 12.6 14.0 16.9
Maximum running current amps 17.1 22.1 22.3 32.8 33.0
Fuse Rating amps 20 25 25 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.3 10.6 10.8 11.1 11.1
Additional Charge kg Refer to Databook
Sound Pressure dBA 58 58 60 62 63
Piping Limits Maximum Length m 100
Maximum Vertical Rise m 40
Piping Connections Liquid mm 9.52 9.52 12.7 12.7 12.7
Discharge mm 15.9 19.1 19.1 22.2 22.2
Gas mm 19.1 22.2 28.6 28.6 28.6
Capacity Index Limit 100~260 125~325 150~390 175~455 200~520
Maximum Number of Connected Indoor Units 5 6 7 9 10
Trade Condensing Unit Price 4,765.00 5,000.00 5,773.00 6,806.00 8,021.00
* Nominal running current stated at -3C ambient air temperature & 75C leaving water temperature 100% connection ratio
Altherma Flex Outdoor Units EMRQ
Altherma Flex Indoor Units EKHVMRD / EKHVMYD
Hot Water Cylinders EKHTSU Accessories
Notes:
i) Refnet joint prices can be found on page 78
ii) Commissioning assistance should be included for each hydrobox
iii) DHW cylinder required for hot water function
Accessories for hydrobox Description Trade price
EKRP1AHT Optional PCB for demand control 104.00
EKRP1HBA Optional PCB for remote alarm monitoring 104.00
RTD-W MODBUS interface for HT hydrobox 205.00
UK.FB2 Fixing box for RTD-W 24.00
EKCC-W Sequence controller 640.00
EKCLWS Additional thermistor for sequence controller 73.00
EKRUAHTB Remote user interface 157.00
EKBUHA6V3 In line back up heater 6kW, 1-phase, 230V 461.00
EKBUHA6W1 In line back up heater 6kW, 3-phase, 400V 461.00
EKFMAHTB Kit for standalone installation with foor
standing hydrobox
277.00
UK.FSHEAT/COMMS Commissioning assistance per hydrobox
1 to 10 hydroboxes
240.00
Commissioning assistance per hydrobox
11 to 20 hydroboxes
216.00
Commissioning assistance per hydrobox
>20 hydroboxes
192.00
Hydrobox & cylinder
shown in
combination
Integrated Solutions
C
o
m
m
e
r
c
i
a
l

H
e
a
t
i
n
g
92
Altherma Flex Communal Heat Pump Centralised
Daikin Altherma Flex type is the rst centralised heating system for schools, public buildings ,
hotels, gyms & apartments that fully incorporates the use of renewable energy sources, making
large buildings more environmentally sustainable by reducing primary energy usage thus
delivering lower running costs and CO
2
emissions.
Altherma Flex Indoor Units EKHBRD
Pre Selected Combinations
Indoor unit (Hydrobox) EKHBRD
011ACV1
EKHBRD
014ACV1
EKHBRD
016ACV1
EKHBRD
011ACY1
EKHBRD
014ACY1
EKHBRD
016ACY1
Function Heating & Hot water
Heating Capacity kW 11 14 16 11 14 16
Cooling capacity kW n/a
Capacity Index 100 125 140 100 125 140
Dimensions HxWxD mm 705 x 600 x 695
Empty Weight kg 145 148
Leaving Water Temperature Range heating C 25~80
Drain valve Yes
Water Pump 92 88 85 92 88 85
Expansion Vessel 12 litres
Material Precoated sheet metal
Colour Metalic Grey
Electrical Details Power Supply 230V 1ph 400V 3ph
Starting current amps 4 4
Nominal running Current* amps 11.6 15.1 18.1 4.3 5.6 6.7
Maximum running current amps 22.5 23.8 23.8 12.5 12.5 12.5
Fuse Rating amps 25 16
Refrigerant Pipe Sizes mm 15.9 Gas, 9.52 Liquid
Water Side Pipe Sizes 1 Female
Sound Pressure Level dBA 43 45 46 43 45 46
Refrigerant R134a Cascade
Trade Unit Price Hydro Box 2,985.00 3,038.00 3,130.00 3,045.00 3,099.00 3,192.00
* Nominal running current stated at -3C ambient air temperature & 75C leaving water temperature 100% connection ratio
Heating capacity (1) A7W35 kW 28.0 31.4 42.0 47.0
Heating capacity (2) A-3W65 kW 23.9 26.7 34.3 38.7
Outdoor unit 1 x EMRQ8 4,765 1 x EMRQ10 5,000 1 x EMRQ12 5,773 1 x EMRQ14 6,806
Hydroboxes 2 x EKHBRD014ACV1 6,076 2 x EKHBRD016ACV1 6,260 3 x EKHBRD014ACV1 9,114 3 x EKHBRD016ACV1 9,390
Demand PCBs 2 x EKRP1AHT 208 2 x EKRP1AHT 208 3 x EKRP1AHT 312 3 x EKRP1AHT 312
Refnets 1 x KHRQM29T9 35 1 x KHRQM29T9 35 1 x KHRQM64H 136 1 x KHRQM64H 136
Trade price 11,084.00 11,503.00 15,335.00 16,644.00
(1) Heating ambient air temperature 7C and leaving water temperature 35C
(2) Heating ambient air temperature -3C and leaving water temperature 65C, capacity stated net of 1 defrost cycle per hour
Notes:
i) Refnet joints can be found on page 78
ii) Commissioning assistance should be included per hydrobox
iii) DHW cylinder required for hot water function
iv) See page 91 for accessories
Outdoor Units EMRQ8A EMRQ10A EMRQ12A EMRQ14A EMRQ16A
Capacity Nominal Heating kW 22.4 28.0 33.6 39.2 44.8
Dimensions Height x Width x Depth mm 1680 x 1300 x 765
Weight kg 331 339
Air Flow Rate m
3
/min 190 190 210 235 240
External Static Pressure High Pa 78.4 78.4 78.4 78.4 78.4
Electrical Details Power Supply 400 V 3ph 50 Hz
Starting current amps 74 74 75 4 4
Nominal running Current* amps 7.6 9.9 12.6 14.0 16.9
Maximum running current amps 17.1 22.1 22.3 32.8 33.0
Fuse Rating amps 20 25 25 40 40
Refrigerant Circuit Refrigerant Type R410a
Refrigerant Charge kg 10.3 10.6 10.8 11.1 11.1
Additional Charge kg Refer to Databook
Sound Pressure dBA 58 58 60 62 63
Piping Limits Maximum Length m 100
Maximum Vertical Rise m 40
Piping Connections Liquid mm 9.52 9.52 12.7 12.7 12.7
Discharge mm 15.9 19.1 19.1 22.2 22.2
Gas mm 19.1 22.2 28.6 28.6 28.6
Capacity Index Limit 100~260 125~325 150~390 175~455 200~520
Maximum Number of Connected Indoor Units 5 6 7 9 10
Trade Condensing Unit Price 4,765.00 5,000.00 5,773.00 6,806.00 8,021.00
* Nominal running current stated at -3C ambient air temperature & 75C leaving water temperature 100% connection ratio
Altherma Flex Outdoor Units EMRQ
93
R
e
f
r
i
g
e
r
a
t
i
o
n
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Refrigeration
CVP 94
ZEAS 95
Integrated Solutions
R
e
f
r
i
g
e
r
a
t
i
o
n
94
CVP is a compact, low noise system which integrates high and low temperature refrigeration
along with heating and cooling into one system. A total solution helping retailers save energy and
the environment.
CVP
Contact your local sales oce for more information.
Benefts
Optimum efciency: inverter driven outdoor units match
system output to the actual demand in order to reach
optimum eciency under all conditions
Various options: supports a wide range of refrigeration and
cooling units
Save energy: by recovering the heat extracted from the
connected refrigeration appliances and using sophisticated
controls, energy savings of up to 50% can be reached
Small footprint: along with reduced piping the small CVP is
ideal for densely populated urban areas
Flexible: VRV (Variable Refrigerant Volume) technology for
fexible application range. Full range of VRV fan coils available
together with air curtains
Minimal noise: low operating sound level
Indoor units LRYEQ16AY1
Casing Colour Ivory white (Munsell code: 5Y7.5/1)
Dimensions HeightxWidthx Depth mm 1,680x1,240x765
Weight kg 370
Heat exchanger Type Cross fn coil
Fan Type Propeller fan
Quantity 2
Air fow rate Cooling Nom. m/min 230
Fan motor Output W 750
Drive Direct drive
Compressor N of compressors 3
Type Hermetically sealed scroll compressor
Piston displacement m/h 13.34 / 10.53 / 10.53
Speed rpm 6,300 / 2,900 / 2,900
Output W 2,500 / 3,600 / 4,500
Starting method Direct on line (inverter driven)
Frequency ON/OFF Less than 6 times/hour
Operation range Evaporator Cooling Min.~Max. CDB -20 @ 0~10
Refrigerant Type R-410A
Charge kg 11.5
Control Electronic expansion valve
Refrigerant oil Type Daphne FVC68D
Charged volume l 1.7 (1)
2.1 (2)
2.1 (3)
4.0 (4)
Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 / 380-415
Voltage range Min. % -10
Max. % 10
Trade price 13,740.00
CVP
LRYEQ-AY1
HEAT
RECOVERY
-10C
-35C
(1) Compressor 1 | (2) Compressor 2 | (3) Compressor 3 | (4) Factory charge of unit
Refer to your local sales oce for further details and prices
Price List 2013 95
R
e
f
r
i
g
e
r
a
t
i
o
n
Compact yet powerful and extremely energy ecient, Daikin
ZEAS condensing units oer an industry-leading solution for all
kinds of installation projects.
ZEAS is an adaptable and controllable solution for all kinds of
environments with uctuating loads such as supermarkets,
hotels, restaurants, hospitals and orists, as well as food
production facilities such as cold storage, and blast coolers
and freezers.
Delivering all the benets of inverter controlled VRV
technology for commercial refrigeration systems, ZEAS oers
a comprehensive product range suitable for low temperature
applications of 5.4 to 15.1 kW at -35/+32C and medium
temperature applications of 12.2 to 37.0 kW at -10C /+32C.
Its small footprint and low sound levels oer installation exibility,
so you can gain larger capacities even in small spaces. Whats
more, the ZEAS solution comes fully packaged and programmed,
with minimal pipe work required, so installation time and cost is
reduced. Plus you can depend on Daikins dedicated after-sales
support to help ensure that commissioning and maintenance go
without a hitch.
Zeas condensing units: a complete solution for
refrigeration applications
When you select a refrigeration condensing unit, you want premium performance with simple
installation and maintenance. Thats why you should specify Daikin ZEAS condensing units.
All in all, its a quality solution that delivers maximum refrigeration
capacity with minimal fuss.
ZEAS condensing units ofer:
Compact system with reduced piping lengths
Higher refrigeration capacity to power consumption ratio
compared with standard systems
COP of up to 3.0
Energy ecient inverter control minimises CO
2
emissions
Utilises energy ecient R-410A refrigerant
To nd out more about ZEAS, please visit www.daikin.co.uk,
email refrigeration@daikin.co.uk or contact your local sales
branch oce.
Outdoor unit LREQ5BY1 LREQ6BY1 LREQ8BY1 LREQ10BY1 LREQ12BY1 LREQ15BY1 LREQ20BY1
Cooling capacity* Nom. kW 12.5 15.2 19.8 23.8 26.5 33.9 37.9
Dimensions Unit H xW xD mm 1,680x635x765 1,680x930x765 1,680x1,240x765
Weight Unit kg 166 242 331 337
Heat exchanger Type Cross fn coil
Fan Type Propeller fan
Quantity 1 2
Air fow rate Cooling Nom. m/min 95 102 171 179 191 230 240
Fan motor Output kW 0.35 0.75 0.35 + 0.35 0.75+0.75
Drive Direct drive
Compressor Type Hermetically sealed scroll compressor Hermetically sealed scroll compressor (x2)
Piston displacement m/h 11.18 13.85 19.68 23.36 25.27 32.24 35.8
Speed rpm 5,280 6,540 4,320+2,900 6,060+2,900 6,960+2,900 5,280+2,900+2,900 6,960+2,900+2,900
Output kW 2.6 3.2 2.1 + 3.6 3.0 + 3.6 3.4 + 3.6 2.6 + 3.6 + 3.6 3.4 + 3.6 + 3.6
Starting method Direct on line (inverter driven) Direct on line (inverter driven) (x2)
Operation range Evaporator Min.~Max. CDB -45~10
Ambient temp. Min.~Max. C -20~43
Refrigerant Type R-410A
Charge kg 5.2 7.9 11.5
Control Electronic expansion valve
Refrigerant oil Type Daphne FVC68D
Charged volume l 1.7 / 2.5 1.7 / 2.5 1.7 / 2.1 / 3.0 1.7 / 2.1 / 3.0 1.7 / 2.1 / 3.0 1.7 / 2.1 / 4.0 1.7 / 2.1 / 4.0
Piping
connections
Liquid 50m or less 9.5 C1220T (Brazing connection) 12.7 C1220T (Brazing connection)
50~130m 9.5 C1220T (Brazing connection) 12.7 C1220T (Brazing connection)
Gas 22.2 C1220T (Brazing connection) 28.6 C1220T (Brazing connection) 34.9 C1220T (Brazing connection)
Power supply Phase/Frequency/Voltage Hz/V 3~/50/380-415
Voltage range Min. % -10
Max. % 10
Current Nominal running
current (RLA) - 50Hz
Compressor Cooling A 7.1 9.2 5.3 + 7.5 7.4 + 7.9 9.8 + 8.3 7.0 + 8.2
+ 8.2
9.5 + 8.4
+ 8.4
Current - 50Hz Starting current (MSC) A - 74 75 84
Minimum Ssc value kVa - 655 899 1,097 761 945
Minimum circuit amps (MCA) A 12.8 13.7 19.3 22.0 24.0 31.4 35.0
Maximum fuse amps (MFA) A 15 25 40
Total overcurrent amps (TOCA) A 15.6 31.5 48.3
Full load amps (FLA) Fan motor A 0.4 0.9 0.4 + 0.4 0.7 + 0.7
Trade price 6,966.00 7,872.00 8,681.00 9,887.00 11,343.00 14,960.00 16,982.00
*Operation conditions of outdoor unit: Te = -10C, outdoor temperature +32C, suction SH10C
R
e
f
r
i
g
e
r
a
t
i
o
n
96
97
A
p
p
l
i
e
d
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Applied
Water Chillers 98
Chilled Water Fan Coils 102
Integrated Solutions
A
p
p
l
i
e
d
98
Air Cooled Water Chillers
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
Air Cooled Inverter Packaged Swing / Scroll Compressor
R410a
EWAQ005ADVP 5.20 - 1-phase 2,020.00
EWAQ006ADVP 6.00 - 1-phase 2,214.00
EWAQ007ADVP 7.10 - 1-phase 2,453.00
EWAQ009ACV3P 8.60 - 1-phase 2,800.00
EWAQ010ACV3P 9.60 - 1-phase 2,963.00
EWAQ011ACV3P 11.10 - 1-phase 3,185.00
EWAQ009ACW1P 9.10 - 3-phase 2,921.00
EWAQ011ACW1P 11.10 - 3-phase 3,211.00
EWAQ013ACW1P 13.30 - 3-phase 3,402.00
Air Cooled Inverter Packaged Scroll Compressor R410a
EWAQ016BAWN 17.4 - 3 - phase 6,137.00
EWAQ021BAWN 21.7 - 3 - phase 5,441.00
EWAQ025BAWN 25.8 - 3 - phase 6,137.00
EWAQ032BAWN 32.3 - 3 - phase 7,081.00
EWAQ040BAWN 43.4 - 3 - phase 9,364.00
EWAQ050BAWN 51.8 - 3 - phase 10,434.00
EWAQ064BAWN 64.5 - 3 - phase 12,049.00
Air cooled packaged scroll compressor R407c
EUWAN5KBZW 11.30 - 3-phase 2,377.00
EUWAN8KBZW 17.90 - 3-phase 3,527.00
EUWAN10KBZW 22.50 - 3-phase 3,989.00
EUWAN12KBZW 26.50 - 3-phase 4,194.00
EUWAN16KBZW 34.60 - 3-phase 5,583.00
EUWAN20KBZW 46.60 - 3-phase 7,058.00
EUWAN24KBZW 55.30 - 3-phase 7,860.00
Cooling Capacity:
Notes:
i) Please contact your local sales ofce for further information on
these products
ii) Nominal cooling capacities are based on 35C ambient,
chilled water @ 12/7C
iii) EWAQ -A series only operates in cooling down to ambients of +10C
iv) The EWAQ064BA delivery does not include ofoading to kerbside.
Additional costs for delivery with a Hi-ab are available on request
Air Cooled Packaged Scroll Compressor R407c
c/w hydraulic pump and expansion vessel
EUWAP5KBZW 11.30 - 3-phase 2,740.00
EUWAP8KBZW 17.90 - 3-phase 3,980.00
EUWAP10KBZW 22.50 - 3-phase 4,473.00
EUWAP12KBZW 26.50 - 3-phase 4,683.00
EUWAP16KBZW 34.60 - 3-phase 5,992.00
EUWAP20KBZW 46.60 - 3-phase 7,540.00
EUWAP24KBZW 55.30 - 3-phase 8,364.00
Air Cooled Packaged Scroll Compressor R407c
c/w hydraulic pump, expansion vessel and bufer tank
EUWAB5KBZW 11.30 - 3-phase 2,994.00
EUWAB8KBZW 17.90 - 3-phase 4,292.00
EUWAB10KBZW 22.50 - 3-phase 4,807.00
EUWAB12KBZW 26.50 - 3-phase 5,025.00
EUWAB16KBZW 34.60 - 3-phase 6,266.00
EUWAB20KBZW 46.60 - 3-phase 7,860.00
EUWAB24KBZW 55.30 - 3-phase 8,701.00
To Fit Model EWAQ-A EWAQ-ADVP EWAQ-ACV3P EWAQ-ACW1P
Part No Description 005 006 007 009 010 011 009 011 013
OP10 Evaporator Heater Tape 270 270 270 298 298 298 298 298 298
OPHP High Static Pump NA NA NA 149 149 149 149 149 149
To Fit Model EWAQ-BA
Part No Description 016 021 025 032 040 050 064
UK57-BA Evaporator Heater Tape 386 386 386 386 486 486 486
UK08B-BA Chilled Water Down to -10 286 286 286 286 386 386 386
UK78-BA Low Lift Pump 429 429 429 572 572 572 572
UK79-BA High Lift Pump 629 629 629 629 857 857 857
To Fit Model EUWAN-KBZW
Part No Description 5 8 10 12 16 20 24
OP10 Evaporator Heater Tape 109 109 109 109 109 109 109
OPHF High Static Fan 16 38 38 38 78 78 78
OPZH Chilled Water Down to -5 163 163 163 163 163 163 163
OPZL Chilled Water Down to -10 163 163 163 163 163 163 163
To Fit Model EUWAP-KBZW
Part No Description 5 8 10 12 16 20 24
OP10 Evaporator Heater Tape 220 220 220 220 220 220 220
OPHP High Static Pump 67 67 67 67 256 256 256
OPHF High Static Fan 16 38 38 38 78 78 78
OPZH Chilled Water Down to -5 163 163 163 163 163 163 163
OPZL Chilled Water Down to -10 163 163 163 163 163 163 163
To Fit Model EUWAB-KBZW
Part No Description 5 8 10 12 16 20 24
OP10 Evaporator Heater Tape 270 270 270 270 270 270 270
OPHP High Static Pump 67 67 67 67 256 256 256
OPHF High Static Fan 16 38 38 38 78 78 78
OPZH Chilled Water Down to -5 163 163 163 163 163 163 163
OPZL Chilled Water Down to -10 163 163 163 163 163 163 163
Fitted Options:
Price List 2013 99
A
p
p
l
i
e
d
Air Cooled Heat Pump Water Chillers
Air Cooled Heat Pump Inverter Packaged
Swing / Scroll Compressor R410a
EWYQ005ADVP 5.20 5.65 1-phase 2,333.00
EWYQ006ADVP 6.00 6.35 1-phase 2,520.00
EWYQ007ADVP 7.10 7.75 1-phase 2,789.00
EWYQ009ACV3P 8.60 9.90 1-phase 3,223.00
EWYQ010ACV3P 9.60 11.40 1-phase 3,348.00
EWYQ011ACV3P 11.10 12.90 1-phase 3,392.00
EWYQ009ACW1P 9.10 10.90 3-phase 3,348.00
EWYQ011ACW1P 11.10 12.40 3-phase 3,633.00
EWYQ013ACW1P 13.30 13.90 3-phase 3,840.00
Air Cooled Heat Pump Inverter Packaged
Scroll Compressor R410a
EWYQ016BAWN 17.4 16.2 3-phase 5,314.00
EWYQ021BAWN 21.7 20.3 3-phase 6,259.00
EWYQ025BAWN 25.8 24.6 3-phase 7,060.00
EWYQ032BAWN 32.3 30.7 3-phase 8,142.00
EWYQ040BAWN 43.4 40.6 3-phase 10,769.00
EWYQ050BAWN 51.8 49.0 3-phase 11,997.00
EWYQ064BAWN 64.5 61.5 3-phase 13,857.00
Air Cooled Heat Pump Packaged Scroll Compressor R407c
EUWYN5KBZW 9.10 11.90 3-phase 2,663.00
EUWYN8KBZW 17.10 18.50 3-phase 4,099.00
EUWYN10KBZW 21.00 24.00 3-phase 4,494.00
EUWYN12KBZW 25.00 27.00 3-phase 4,764.00
EUWYN16KBZW 34.20 37.00 3-phase 6,440.00
EUWYN20KBZW 40.00 46.00 3-phase 7,809.00
EUWYN24KBZW 50.00 54.00 3-phase 8,605.00
Cooling Capacity:
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
Notes:
i) Please contact your local sales ofce for further information on
these products
ii) Nominal cooling capacities are based on 35C ambient,
chilled water @ 12/7C
iii) Nominal heating capacities are based on 7C db / 6C wb ambient,
water @ 45 / 50C
iv) EWYQ -A series only operates in cooling down to ambients of +10C
v) The EWYQ064BA delivery does not include ofoading to kerbside.
Additional costs for delivery with a Hi-ab are available on request
Air Cooled Heat Pump Packaged Scroll Compressor R407c
c/w hydraulic pump and expansion vessel
EUWYP5KBZW 9.10 11.90 3-phase 3,033.00
EUWYP8KBZW 17.10 18.50 3-phase 4,579.00
EUWYP10KBZW 21.00 24.00 3-phase 4,989.00
EUWYP12KBZW 25.00 27.00 3-phase 5,273.00
EUWYP16KBZW 34.20 37.00 3-phase 6,867.00
EUWYP20KBZW 40.00 46.00 3-phase 8,300.00
EUWYP24KBZW 50.00 54.00 3-phase 9,108.00
Air Cooled Heat Pump Packaged Scroll Compressor R407c
c/w hydraulic pump, expansion vessel and bufer tank
EUWYB5KBZW 9.10 11.90 3-phase 3,288.00
EUWYB8KBZW 17.10 18.50 3-phase 4,714.00
EUWYB10KBZW 21.00 24.00 3-phase 5,276.00
EUWYB12KBZW 25.00 27.00 3-phase 5,514.00
EUWYB16KBZW 34.20 37.00 3-phase 6,883.00
EUWYB20KBZW 40.00 46.00 3-phase 8,629.00
EUWYB24KBZW 50.00 54.00 3-phase 9,557.00
To Fit Model EWYQ-A EWYQ-ADVP EWYQ-ACV3P EWYQ-ACW1P
Part No Description 005 006 007 009 010 011 009 011 013
OP10 Evaporator Heater Tape 270 270 270 298 298 298 298 298 298
OPHP High Static Pump NA NA NA 149 149 149 149 149 149
To Fit Model EWYQ-BA
Part No Description 016 021 025 032 040 050 064
UK57-BA Evaporator Heater Tape 386 386 386 386 486 486 486
UK08B-BA Chilled Water Down to -10 286 286 286 286 386 386 386
UK78-BA Low Lift Pump 429 429 429 572 572 572 572
UK79-BA High Lift Pump 629 629 629 629 857 857 857
To Fit Model EUWYN-KBZW
Part No Description 5 8 10 12 16 20 24
OP10 Evaporator Heater Tape 109 109 109 109 109 109 109
OPHF High Static Fan 16 38 38 38 78 78 78
OPZH Chilled Water Down to -5 163 163 163 163 163 163 163
OPZL Chilled Water Down to -10 163 163 163 163 163 163 163
To Fit Model EUWYP-KBZW
Part No Description 5 8 10 12 16 20 24
OP10 Evaporator Heater Tape 220 220 220 220 220 220 220
OPHP High Static Pump 67 67 67 67 256 256 256
OPHF High Static Fan 16 38 38 38 78 78 78
OPZH Chilled Water Down to -5 163 163 163 163 163 163 163
OPZL Chilled Water Down to -10 163 163 163 163 163 163 163
To Fit Model EUWYB-KBZW
Part No Description 5 8 10 12 16 20 24
OP10 Evaporator Heater Tape 270 270 270 270 270 270 270
OPHP High Static Pump 67 67 67 67 256 256 256
OPHF High Static Fan 16 38 38 38 78 78 78
OPZH Chilled Water Down to -5 163 163 163 163 163 163 163
OPZL Chilled Water Down to -10 163 163 163 163 163 163 163
Fitted Options:
Integrated Solutions
A
p
p
l
i
e
d
100
Water Cooled Chillers
Water Cooled Packaged Scroll Compressor R407C
EWWP014KBW1N 12.90 - 3-phase 2,557.00
EWWP022KBW1N 21.40 - 3-phase 3,371.00
EWWP028KBW1N 27.80 - 3-phase 3,873.00
EWWP035KBW1N 32.30 - 3-phase 4,507.00
EWWP045KBW1N 42.80 - 3-phase 5,552.00
EWWP055KBW1N 55.70 - 3-phase 6,201.00
EWWP065KBW1N 64.70 - 3-phase 6,926.00
Notes:
i) Please contact your local sales ofce for further information on
these products
ii) Nominal cooling capacities are based on chilled water @ 12/7C,
condenser water @ 30/35C
To Fit Model EWWP-KAW1N
Part No Description 014 022 028 035 045 055 065
OPZH Chilled Water Down to -5 163 163 163 163 163 163 163
OPZL Chilled Water Down to -10 163 163 163 163 163 163 163
Fitted Options:
Cooling Capacity:
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
Condenserless Chillers
Condenserless Packaged Scroll Compressor R407C
EWLP012KBW1N 12.10 - 3-phase POA
EWLP020KBW1N 20.00 - 3-phase POA
EWLP026KBW1N 26.80 - 3-phase POA
EWLP030KBW1N 31.20 - 3-phase POA
EWLP040KBW1N 40.00 - 3-phase POA
EWLP055KBW1N 53.70 - 3-phase POA
EWLP065KBW1N 62.40 - 3-phase POA
Notes:
i) Please contact your local sales ofce for further information on
these products
ii) Nominal cooling capacities are based on chilled water @ 12/7C,
condensing temperature @ 45C, liquid temperature @40C
To Fit Model EWLP-KAW1N
Part No Description 012 020 026 030 040 055 065
OPZH Chilled Water Down to -5 POA POA POA POA POA POA POA
OPZL Chilled Water Down to -10 POA POA POA POA POA POA POA
Fitted Options:
Cooling Capacity:
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
Price List 2013 101
A
p
p
l
i
e
d
Applied Systems Kit Options
Model Description Trade Price
BHGP26A1 Digital Pressure gauges - EWAQ/EWYQ-BA 262.00
DTA104A62 External control adaptor Low noise & demand limit - EWAQ/EWYQ-BA 216.00
EHMC10A10 HYDRAULIC MODULE -Normal static + anti-freeze protection - EWWP014~022/EWLP012~020 1,635.00
EHMC10A80 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP014~022/EWLP012~020 1,740.00
EHMC15A10 HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP028~035/EWLP026~030 1,740.00
EHMC15A80 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP028~035/EWLP026~030 1,811.00
EHMC30A10 HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP045~065/EWLP040~065 1,951.00
EHMC30A80 HYDRAULIC MODULE-High static + anti-freeze protection - EWWP045~065/EWLP040~065 1,951.00
EKAC10C Address card for connection to BMS - EUWA/Y(N,P,B)5-24KBZW,EWWP,EWLP (note not available on the modular EWWP) 84.00
EKRUMCA Remote Control- EUWA/Y(N,P,B)5-24KBZW,EWWP,EWLP (needs EKAC10C) 159.00
EKBT Bufertank 200I - EUWA/Y5-24KBZW 1,075.00
EKGAU10/12KA Gauges kit 10/12Hp-units - EUWA/Y10-12KBZW 163.00
EKGAU16KA Gauges kit 16Hp-units - EUWA/Y16 KBZW 262.00
EKGAU20/24KA Gauges kit 20/24Hp-units - EUWA/Y20-24KBZW 262.00
EKGAU5/8KA Gauges kit 5/8Hp-units - EUWA/Y5-8KBZW 163.00
EKLS1 Low noise operation EWLP012~EWWP14 151.00
EKLS2 Low noise operation EWLP02~030, EWWP22-35 151.00
EKLS2 X 2 Low noise operation EWLP040~065, EWWP45-65 302.00
EKRP1AHT Demand PCB / Outputs - EWAQ/EWYQ-BA (2 x on size 40/50/64) 104.00
EKRUAHTB Remote user interface (in parallel) - EWAQ/EWYQ-BA 157.00
RTD-W MODBUS Interface - EWAQ/EWYQ-BA 205.00
Loose Accessory Options:
Integrated Solutions
A
p
p
l
i
e
d
102
Capacity conditions
EUROVENT conditions
Cooling
27C db / 19C wb - Entering water 7C - Leaving water 12C
Heating 4 Pipe
20C db - Entering water 70C - Leaving water 60C
Heating 2 Pipe
20C db - Entering water 50C - Flow rate as in cooling mode
TYPICAL UK cooling conditions
22C db / 16.0C wb - Entering water 7C - Leaving water 12C
0 Pa External Static Pressure
0% Glycol
FWB & FWD Ducted FCU - Above capacities are based on 30 Pa
External Static Pressure
FWM Uncased & FWE Ducted FCU - Based on 20 pa external static
Fan Coil Units
Daikins fan coil range are manufactured in Europe to the same high standard,
high quality and reliability as their DX counterparts.
An extensive range of control and valve options are available to complement
these quiet and fashionable units.
Price List 2013 103
A
p
p
l
i
e
d
Cased Low Wall Mount Type 2-pipe FWV01DTN FWV15DTN FWV02DTN FWV25DTN FWV03DTN FWV35DTN FWV04DTN FWV06DTN FWV08DTN FWV10DTN
Capacity UK Total Cooling kW 0.82 0.92 1.09 1.24 1.48 1.75 2.14 2.39 3.29 4.00
Nominal Cooling kW 1.54 1.74 2.09 2.42 2.93 3.51 4.33 4.77 6.71 8.02
Nominal Heating kW 2.14 2.2 2.57 3.2 3.81 4.78 5.63 6.36 7.83 10.03
Dimensions Height mm 564 564 564 564 564 564 564 564 564 564
Width mm 774 774 774 987 987 1194 1194 1194 1404 1404
Depth mm 226 226 226 226 226 226 226 226 251 251
Weight kg 19 20 20 25 25 30 30 31 41 41
Sound Power High dBA 45 49 50 48 47 52 52 56 58 64
Air Flow Rate m
3
/min 5.32 5.73 5.73 7.36 7.37 10.66 11.77 13.08 16.85 23.22
Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4
Electrical Data Power Supply 1ph
Trade Fan Coil Price 148.00 155.00 163.00 174.00 179.00 196.00 206.00 222.00 295.00 335.00
Cased Low Wall Mount Type 4-pipe FWV01DFN FWV15DFN FWV02DFN FWV25DFN FWV03DFN FWV35DFN FWV04DFN FWV06DFN FWV08DFN FWV10DFN
Capacity UK Total Cooling kW 0.77 0.90 0.99 1.22 1.37 1.73 2.11 2.33 3.27 3.92
Nominal Cooling kW 1.46 1.69 1.9 2.38 2.87 3.46 4.33 4.67 6.64 7.88
Nominal Heating kW 1.9 2.02 2.1 2.92 3.08 4.8 5.05 5.3 7.91 9.3
Dimensions Height mm 564 564 564 564 564 564 564 564 564 564
Width mm 774 774 774 987 984 1194 1194 1194 1404 1404
Depth mm 226 226 226 226 226 226 226 226 251 251
Weight kg 20 21 21 26 26 32 32 33 44 44
Sound Power High dBA 45 49 50 48 47 51 56 59 60 66
Air Flow Rate m
3
/min 5.12 5.5 5.45 7.2 7.18 10.46 11.5 12.72 16.63 22.7
Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4
Electrical Data Power Supply 1ph
Trade Fan Coil Price 171.00 179.00 187.00 201.00 208.00 224.00 240.00 259.00 338.00 378.00
Floor Standing Fan Coil Units
Cased Flexi Type 2-pipe FWL01DTN FWL15DTN FWL02DTN FWL25DTN FWL03DTN FWL35DTN FWL04DTN FWL06DTN FWL08DTN FWL10DTN
Capacity UK Total Cooling kW 0.82 0.92 1.09 1.24 1.48 1.75 2.14 2.39 3.29 4.00
Nominal Cooling kW 1.54 1.74 2.09 2.42 2.93 3.51 4.33 4.77 6.71 8.02
Nominal Heating kW 2.14 2.2 2.57 3.2 3.81 4.78 5.63 6.36 7.83 10.03
Dimensions Height mm 564 564 564 564 564 564 564 564 564 564
Width mm 774 774 774 987 987 1194 1194 1194 1404 1404
Depth mm 226 226 226 226 226 226 226 226 251 251
Weight kg 20 21 21 27 27 32 32 33 44 44
Sound Power High dBA 45 49 50 48 48 52 53 56 61 67
Air Flow Rate m
3
/min 5.32 5.73 5.73 7.37 7.37 10.66 11.77 13.08 16.85 23.22
Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4
Electrical Data Power Supply 1ph
Trade Fan Coil Price 161.00 171.00 180.00 188.00 201.00 216.00 227.00 245.00 330.00 372.00
Cased Flexi Type 4-pipe FWL01DFN FWL15DFN FWL02DFN FWL25DFN FWL03DFN FWL35DFN FWL04DFN FWL06DFN FWL08DFN FWL10DFN
Capacity UK Total Cooling kW 0.77 0.90 0.99 1.22 1.37 1.73 2.11 2.33 3.27 3.92
Nominal Cooling kW 1.46 1.69 1.9 2.38 2.87 3.46 4.33 4.67 6.64 7.88
Nominal Heating kW 1.9 2.02 2.1 2.92 3.08 4.8 5.05 5.3 7.91 9.3
Dimensions Height mm 564 564 564 564 564 564 564 564 564 564
Width mm 774 774 774 987 987 1194 1194 1194 1404 1404
Depth mm 226 226 226 226 226 226 226 226 251 251
Weight kg 21 22 22 28 28 34 34 35 46 46
Sound Power High dBA 45 49 50 48 47 51 56 59 60 66
Air Flow Rate m
3
/min 5.12 5.5 5.45 7.2 7.18 10.46 11.5 12.72 16.63 22.7
Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4
Electrical Data Power Supply 1ph
Trade Fan Coil Price 188.00 198.00 204.00 219.00 227.00 251.00 266.00 282.00 375.00 417.00
Flexi Fan Coil Units
Integrated Solutions
A
p
p
l
i
e
d
104
Concealed Flexi Type 2-pipe FWM01DTN FWM15DTN FWM02DTN FWM25DTN FWM03DTN FWM35DTN FWM04DTN FWM06DTN FWM08DTN FWM10DTN
Capacity UK Total Cooling kW 0.66 0.92 0.87 1.24 1.27 1.75 1.97 2.11 3.11 3.71
Nominal Cooling kW 1.54 1.74 2.09 2.42 2.93 3.51 4.33 4.77 6.71 8.02
Nominal Heating kW 2.14 2.2 2.57 3.2 3.81 4.78 5.68 6.36 7.83 10.03
Dimensions Height mm 535 535 535 535 535 535 535 535 535 535
Width mm 584 584 584 794 794 1004 1004 1004 1214 1214
Depth mm 224 224 224 224 224 224 224 224 249 249
Weight kg 14 15 15 19 19 23 23 23 32 32
Sound Power High dBA 45 49 50 48 47 52 52 56 58 64
Air Flow Rate m
3
/min 5.32 5.73 5.73 7.37 7.37 10.66 11.77 13.08 16.85 23.22
Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4
Electrical Data Power Supply 1ph
Trade Fan Coil Price 122.00 130.00 135.00 145.00 150.00 161.00 167.00 184.00 242.00 275.00
Concealed Flexi Type 4-pipe FWM01DFN FWM15DFN FWM02DFN FWM25DFN FWM03DFN FWM35DFN FWM04DFN FWM06DFN FWM08DFN FWM10DFN
Capacity UK Total Cooling kW 0.64 0.90 0.82 1.22 1.26 1.73 1.94 2.08 3.08 3.63
Nominal Cooling kW 1.46 1.69 1.9 2.38 2.87 3.46 4.33 4.67 6.64 7.88
Nominal Heating kW 1.9 2.02 2.1 2.92 3.08 4.8 5.05 5.3 7.91 9.3
Dimensions Height mm 535 535 535 535 535 535 535 535 535 535
Width mm 584 584 584 794 794 1004 1004 1004 1214 1214
Depth mm 224 224 224 224 224 224 224 224 249 249
Weight kg 15 16 16 20 20 25 25 25 34 34
Sound Power High dBA 45 49 50 48 47 51 56 59 60 66
Air Flow Rate m
3
/min 5.12 5.73 5.45 7.37 7.18 10.66 11.5 12.72 16.63 22.7
Water Connections inch 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4
Electrical Data Power Supply 1ph
Trade Fan Coil Price 147.00 153.00 158.00 172.00 177.00 192.00 203.00 217.00 285.00 319.00
Low Static Concealed Flexi Fan Coil Units
FWV, FWL, FWM 1-35 4 -6 8 -10
2-pipe 3-way valve kits c/w lockshields E2MV03A6 E2MV06A6 E2MV10A6
118.00 118.00 125.00
4-pipe 3-way valve kits c/w lockshields E4MV03A6 E4MV06A6 E4MV10A6
212.00 212.00 222.00
Simplifed 2 pipe 3-way valve kit w/o lockshields E2MVD03A6 E2MVD06A6 E2MVD10A6
68.00 70.00 72.00
Simplifed 4 pipe 3-way valve kit w/o lockshields E4MVD03A6 E4MVD06A6 E4MVD10A6
128.00 130.00 132.00
2-way simplifed valve (primary heat exchanger) E2MV207A6 E2MV210A6
50.00 50.00
2-way simplifed valve (auxiliary heat exchanger) E2MV207A6
50.00
Vertical drainpan EDPVB6
3.00
Horizontal drainpan EDPHB6
3.00
Standard Electronic Controller FWEC1A
63.00
Advanced Electronic Controller FWEC2A
80.00
Advanced Plus Electronic Controller FWEC3A
111.00
On board installation kit
(FWV & FWL - Low Wall Mounted Only)
FWECKA
10.00
Master slave option EPIMSA6
82.00
Return Air Sensor FWTSKA
7.00
Loose Accessory Options: Notes:
FWEC1A individual controller can operate
up to 4 fan coils by adding a EPIMSA6
FWEC2A can operate up to 247 fan coils as
master slave control (1 per fan coil required)
FWEC3A can operate up to 247 fan coils as
master slave control, plus weekly schedule
timer, proportional valve control and 2 digital
outputs (1 per fan coil required)
Please note that
i) Each controller version includes the
water probe
ii) The on board installation kit includes a
remote air probe (If installed the internal
fan coil robe is disabled).
Floor Standing and Flexi Fan Coil Unit Accessories
Price List 2013 105
A
p
p
l
i
e
d
Concealed Ducted Type 2-pipe FWE02CT FWE03CT FWE04CT FWE06CT FWE07CT FWE08CT FWE10CT
Capacity UK Total Cooling kW 1.10 1.59 2.37 3.65 3.46 4.16 5.78
Nominal Cooling kW 2.17 3.22 4.34 6.06 6.83 7.84 9.96
Nominal Heating kW 2.79 4.28 5.61 7.86 9.26 10.5 13
Dimensions Height mm 253 253 253 253 253 253 253
Width mm 705 875 1005 1205 1455 1555 1815
Depth mm 605 605 605 605 605 605 605
Weight kg 17 20 24 28 37 39 46
Sound Power Super High dBA 51 61 58 62 62 64 65
Air Flow Rate m
3
/min 7.16 10.63 15.16 19.92 25.98 29.22 36.28
Water Connections inch 3/4
Electrical Data Power Supply 1ph
Trade Fan Coil Price 129.00 147.00 159.00 208.00 224.00 262.00 316.00
Concealed Ducted Type 4-pipe FWE02CF FWE03CF FWE04CF FWE06CF FWE07CF FWE08CF FWE10CF
Capacity UK Total Cooling kW 1.03 1.52 2.22 3.33 3.05 3.87 5.07
Nominal Cooling kW 2.1 3.16 3.98 6.05 6.78 7.79 9.91
Nominal Heating kW 2.3 3.53 4.56 6.17 7.6 8.52 10.4
Dimensions Height mm 253 253 253 253 253 253 253
Width mm 720 890 1020 1220 1470 1570 1830
Depth mm 605 605 605 605 605 605 605
Weight kg 18 22 25 30 40 41 49
Sound Power Super High dBA 51 61 58 62 62 64 65
Air Flow Rate m
3
/min 6.94 10.44 13.91 19.88 25.79 29.03 36.1
Water Connections inch 3/4
Electrical Data Power Supply 1ph
Trade Fan Coil Price 151.00 172.00 187.00 240.00 256.00 299.00 353.00
Low Static Ducted Fan Coil Units
FWE FWE
2-pipe 2-way 230v on/of valve kit EK2MV2B10CS
41.00
2-pipe 3-way 230v on/of valve kit EK2MV3B10CS
55.00
4-pipe 2-way 230v on/of valve kit EK4MV2B10CS
80.00
4-pipe 3-way 230v on/of valve kit EK4MV3B10CS
94.00
Standard Electronic Controller FWEC1A
63.00
Advanced Electronic Controller FWEC2A
80.00
Advanced Plus Electronic Controller FWEC3A
111.00
Return Air Sensor FWTSKA
7.00
Master slave interface EPIMSA6
82.00
Loose Accessory Options: Notes:
FWEC1A individual controller can operate
up to 4 fan coils by adding a EPIMSA6
FWEC2A can operate up to 247 fan coils as
master slave control ( 1 per fan coil required)
FWEC3A can operate up to 247 fan coils as
master slave control, plus weekly schedule
timer, proportional valve control and 2 digital
outputs ( 1 per fan coil required)
Please note that
i) Each controller version includes the
water probe
ii) The on board installation kit includes a
remote air probe( If installed the internal
fan coil robe is disabled).
Integrated Solutions
A
p
p
l
i
e
d
106
Concealed Ducted Type 2-pipe FWB02BT*** FWB03BT*** FWB04BT*** FWB05BT*** FWB06BT*** FWB07BT*** FWB08BT*** FWB09BT*** FWB10BT***
Capacity UK Total Cooling kW 1.71 2.09 2.26 3 3.24 3.84 4.63 5.34 6.64
Nominal Cooling kW 2.61 3.14 3.49 5.08 5.45 6.47 7.57 8.67 10.34
Nominal Heating kW 5.47 6.01 6.47 10.31 11.39 12.28 15.05 16.85 18.78
Dimensions Height mm 239 239 239 239 239 239 239 239 239
Width mm 1039 1039 1039 1389 1389 1389 1739 1739 1739
Depth mm 609 609 609 609 609 609 609 609 609
Weight kg 23 24 26 31 33 35 43 45 48
Sound Power High dBA 56 56 56 59 59 59 69 69 69
Air Flow Rate m
3
/min 6.67 6.67 6.67 13.33 13.33 13.33 20 20 20
Water Connections inch 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Electrical Data Power Supply 1ph
Trade Fan Coil Price - no valves FWB02BTN FWB03BTN FWB04BTN FWB05BTN FWB06BTN FWB07BTN FWB08BTN FWB09BTN FWB10BTN
219.00 233.00 248.00 299.00 309.00 338.00 409.00 431.00 459.00
Trade Fan Coil Price - complete with valves FWB02BTV FWB03BTV FWB04BTV FWB05BTV FWB06BTV FWB07BTV FWB08BTV FWB09BTV FWB10BTV
288.00 303.00 317.00 369.00 378.00 409.00 481.00 506.00 535.00
Trade Fan Coil Price - complete with electronic heater*,
no valves
FWB02BTNE FWB03BTNE FWB04BTNE FWB05BTNE FWB06BTNE FWB07BTNE FWB08BTNE FWB09BTNE FWB10BTNE
353.00 367.00 382.00 448.00 457.00 486.00 567.00 589.00 618.00
Trade Fan Coil Price - complete with electronic heater*
and valves
FWB02BTVE FWB03BTVE FWB04BTVE FWB05BTVE FWB06BTVE FWB07BTVE FWB08BTVE FWB09BTVE FWB10BTVE
423.00 436.00 451.00 517.00 528.00 557.00 641.00 663.00 692.00
Medium Static Ducted Fan Coil Units
FWB 2 - 4 5 - 7 8 - 10
Additional Heat exchanger EAH04A6 EAH07A6 EAH10A6
87.00 101.00 137.00
3-way valve add.h/e E2MV307A6 E2MV310A6
89.00 89.00
2-way valve add.h/e E2MV207A6 E2MV210A6
50.00 50.00
Master slave interface EPIMSA6
82.00
Standard Electronic Controller FWEC1A
63.00
Advanced Electronic Controller FWEC2A
80.00
Advanced Plus Electronic Controller FWEC3A
111.00
Return Air Sensor FWTSKA
7.00
Loose Accessory Options: Notes:
FWEC1A individual controller can operate
up to 4 fan coils by adding a EPIMSA6
FWEC2A can operate up to 247 fan coils as
master slave control ( 1 per fan coil required)
FWEC3A can operate up to 247 fan coils as
master slave control, plus weekly schedule
timer, proportional valve control and 2 digital
outputs (1 per fan coil required)
Please note that:
i) Each controller version includes the
water probe.
Price List 2013 107
A
p
p
l
i
e
d
Concealed Ducted Type 2-pipe FWD04AT FWD06AT FWD08AT FWD10AT FWD12AT FWD16AT FWD18AT
Capacity UK Total Cooling kW 2.15 3.48 4.44 4.92 7.21 8.96 9.91
Nominal Cooling kW 3.9 6.2 7.8 8.82 11.9 16.4 18.3
Nominal Heating kW 4.05 7.71 9.43 10.79 14.45 19.81 21.92
Dimensions Height mm 280 280 280 280 352 352 352
Width mm 754 964 1174 1174 1174 1384 1384
Depth mm 559 559 559 559 718 718 718
Weight kg 33 41 47 49 65 77 80
Sound Power High dBA 66 69 72 72 74 78 78
Air Flow Rate m
3
/min 13.33 20.83 26.67 26.67 36.67 50 50
Water Connections inch 3/4 3/4 3/4 3/4 1 1 1
Electrical Data Power Supply 1ph
Trade Fan Coil Price 264.00 348.00 406.00 452.00 562.00 721.00 792.00
Concealed Ducted Type 4-pipe FWD04AF FWD06AF FWD08AF FWD10AF FWD12AF FWD16AF FWD18AF
Capacity UK Total Cooling kW 2.15 3.48 4.44 4.92 7.21 8.96 9.91
Nominal Cooling kW 3.9 6.2 7.8 8.82 11.9 16.4 18.3
Nominal Heating kW 4.05 7.71 9.43 10.79 14.45 19.81 21.92
Dimensions Height mm 280 280 280 280 352 352 352
Width mm 754 964 1174 1174 1174 1384 1384
Depth mm 559 559 559 559 718 718 718
Weight kg 35 43 50 52 71 83 86
Sound Power High dBA 66 69 72 72 74 78 78
Air Flow Rate m
3
/min 13.33 20.83 26.67 26.67 36.67 50 50
Water Connections inch 3/4 3/4 3/4 3/4 1 1 1
Electrical Data Power Supply 1ph
Trade Fan Coil Price 309.00 404.00 472.00 523.00 658.00 836.00 916.00
High Static Ducted Fan Coil Units
FWD 4 6 8 -10 12 16 -18
2-pipe 3-way valve ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6
125.00 125.00 125.00 130.00
4-pipe 3-way valve ED4MV04A6 ED4MV10A6 2x ED2MV12A6 2 x ED2MV18A6
239.00 239.00 250.00 260.00
Vertical Drain pan EDDPV10A6 EDDPV18A6
10.00 10.00
Horizontal Drain Pan EDDPH10A6 EDDPH18A6
12.00 12.00
Master slave interface EPIMSA6 -
82.00 -
Power interface (S) EPIB6
82.00
Standard Electronic Controller FWEC1A
63.00
Advanced Electronic Controller FWEC2A
80.00
Advanced Plus Electronic Controller FWEC3A
111.00
Return Air Sensor FWTSKA
7.00
Loose Accessory Options: Notes:
FWEC1A is designed as an individual unit
controller. Power interface EPIB6 is required
for unit size 16 and 18 can operate up to
4 fan coils by adding a EPIMSA6.
If using this controller to operate up to 4
fan coil units by adding a EPIMSA6 you will
require a EPIB6 power interface for unit
size 12,16,18.
FWEC2A can operate up to 247 fan coils as
master slave control ( 1 per fan coil required).
Power interface EPIB6 is required for each
unit size 16 and 18.
FWEC3A can operate up to 247 fan coils
as master slave control, plus weekly
schedule timer, proportional valve control
(by others) and 2 digital outputs ( 1 per fan
coil required).
Please note that:
i) Each controller version includes the
water probe.
Integrated Solutions
A
p
p
l
i
e
d
108
600sq Cassette Type 2-pipe c/w Decoration Panel
and Remote Controller
FWF02BT FWF03BT FWF04BT FWF05BT
Capacity UK Total Cooling kW 1.20 1.9 2.5 3.1
Nominal Cooling kW 2 3.2 4.2 5.2
Nominal Heating kW 2.9 4 5.4 6.7
Dimensions Height mm 260 260 260 260
Width mm 575 575 575 575
Depth mm 575 575 575 575
Weight kg 19 19 19 19
Sound Power High dBA 44 44 50 55
Air Flow Rate m
3
/min 7.9 7.9 11.2 14.9
Water Connections inch 3/4 BSP Female
Electrical Data Power Supply 1 ph
Trade Fan Coil Price 498.00 524.00 553.00 591.00
600sq Cassette Type 4-pipe c/w Decoration Panel
and Remote Controller
FWF02BF FWF03BF FWF04BF FWF05BF
Capacity UK Total Cooling kW 1.10 1.6 2 2.5
Nominal Cooling kW 2 2.7 3.5 4.5
Nominal Heating kW 3.9 3.8 4.9 6.1
Dimensions Height mm 260 260 260 260
Width mm 575 575 575 575
Depth mm 575 575 575 575
Weight kg 19 20 20 20
Sound Power High dBA 44 46 52 57
Air Flow Rate m
3
/min 7.9 7.2 10.4 13.9
Water Connections inch 3/4 BSP Female
Electrical Data Power Supply 1 ph
Trade Fan Coil Price 530.00 553.00 591.00 624.00
600 Sq Cassette Fan Coil Units
Cassette Type 2-pipe c/w Decoration Panel
and Remote Controller
FWC06BT FWC07BT FWC08BT FWC09BT
Capacity UK Total Cooling kW 3.30 4.1 4.3 4.8
Nominal Cooling kW 5.8 6.8 7.7 8.7
Nominal Heating kW 8 8.9 10.6 12.1
Dimensions Height mm 288 288 288 288
Width mm 840 840 840 840
Depth mm 840 840 840 840
Weight kg 26 26 26 26
Sound Power High dBA 46 49 55 59
Air Flow Rate m
3
/min 17.7 20.6 25.4 30.8
Water Connections inch 3/4 BSP Female
Electrical Data Power Supply 1 ph
Trade Fan Coil Price 625.00 641.00 657.00 684.00
Cassette Type 4-pipe c/w Decoration Panel
and Remote Controller
FWC06BF FWC07BF FWC08BF FWC09BF
Capacity UK Total Cooling kW 3.30 4 4.3 4.8
Nominal Cooling kW 5.8 6.6 7.6 8.7
Nominal Heating kW 7.5 8.4 9.7 11
Dimensions Height mm 288 288 288 288
Width mm 840 840 840 840
Depth mm 840 840 840 840
Weight kg 29 29 29 29
Sound Power High dBA 43 47 53 57
Air Flow Rate m
3
/min 17.1 19.9 24.6 29
Water Connections inch 3/4 BSP Female
Electrical Data Power Supply 1 ph
Trade Fan Coil Price 653.00 676.00 694.00 711.00
Cassette Fan Coil Units
Price List 2013 109
A
p
p
l
i
e
d
FWF/FWC FWF/FWC
Remote wired controller (requires KJB212A) BRC315D
65.00
Recessed fxing box for BRC315D & DCS301B51 KJB212A
36.00
Intelligent touch controller DCS601C51
1,608.00
Recessed fxing box for DCS601C51 KJB411A
67.00
Unit/Group adapter pcb KRP4A53
65.00
Unit/Group adapter pcb complete with
installation box
KRP4A53/UK.FB2
89.00
System adaptor pcb KRP2A52
173.00
System adaptor pcb complete with
installation box
KRP2A52/UK.FB2
197.00
Optional pcb for connection to ModBus EKFCMBCB
53.00
2-Way on / of valve kit EKMV2C09B
56.00
3-Way on / of valve kit EKMV3C09B
62.00
Valve control PCB EKRP1C11
98.00
FWC only FWC only
Wireless remote control heat pump BRC7FA532F
149.00
Wireless remote control cooling only BRC7F533F
149.00
Remote air sensor KRCS01-4
46.00
Installation box for an EKRP1C11 valve PCB UK.FB2
36.00
FWF only FWF only
Wireless remote control heat pump BRC7E530
118.00
Wireless remote control cooling only BRC7E531
118.00
System adaptor pcb KRCS01-1
45.00
Remote on/of control interface kit EKRORO
15.00
Installation box for an EKRP1C11 valve PCB UK.FB2
36.00
Loose Accessory Options: Notes:
i) FWF and FWC Cassette Fan Coil prices
include decoration panel
ii) It is not possible to use Intelligent Touch
control for combination with both VRV
and water based fan coils
FWF-Valve control requirements
2 pipe unit: 1 x valve kit + 1 x installation
box for PCB KRP1BA101 + 1 x valve control
PCB EKRP1C11
4 pipe unit: 2 x valve kit + 1 x installation
box for PCB KRP1BA101 + 1 x valve control
PCB EKRP1C11
FWC-Valve control requirements
2 pipe unit: 1 x valve kit + 1 x installation
box for PCB KRP1H98 + 1 x valve control
PCB EKRP1C11
4 pipe unit: 2 x valve kit + 1 x installation
box for PCB KRP1H98 + 1 x valve control
PCB EKRP1C11
Cassette Accessories
Cased High Wall Mount Type 2-pipe FWT02CT FWT03CT FWT04CT FWT05CT FWT06CT
Capacity UK Total Cooling kW 1.59 1.67 2.1 2.9 3.41
Nominal Cooling kW 2.43 2.7 3.31 4.54 5.28
Nominal Heating kW 3.22 3.52 4.4 6.01 5.26
Dimensions Height mm 288 288 288 310 310
Width mm 800 800 800 1065 1065
Depth mm 206 206 206 224 224
Weight kg 10 10 10 15 15
Sound Power High dBA 45 48 55 55 59
Air Flow Rate m
3
/min 7.36 7.93 10.48 14.43 17.55
Water Connections inch 1/2 1/2 1/2 1/2 1/2
Electrical Data Power Supply 1ph
Trade Fan Coil Price 192.00 200.00 229.00 277.00 295.00
Wall Mounted Fan Coil Units
FWT FWT
Standard wired remote controller MERCA
74.00
Simplifed wired remote controller SRC-HPA
38.00
Wireless controller for heat pump WRC-HPB
14.00
Loose Accessory Options: Notes:
i) FWT fan coils are optimised for valveless
control in cooling. We would recommend
that a valve is ftted if being used for
heating only and for more precise control
in cooling.
ii) We would recommend the feld supply of
a 240V - 4 port 3 way valve complete with
240V actuator.
A
p
p
l
i
e
d
110
111
M
i
s
c
e
l
l
a
n
e
o
u
s
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Miscellaneous
Schematics & Malfunction Codes 112
Delivery Information 114
Goods Returns Procedure 115
Field Quality Service 116
Warranty 117
Training 118
Terms & Conditions 120
Integrated Solutions
M
i
s
c
e
l
l
a
n
e
o
u
s
112
Wiring Diagram
Sky Air & Split Interconnecting Wiring
Wiring Adaptor for External Control
KRP4A51-52-53-54
Price List 2013 113
M
i
s
c
e
l
l
a
n
e
o
u
s
Wiring Adaptor for External Control
KRP4A51-52-53-54
Overall Malfunction Display on Daikin LCD Controller
2nd
1st
0 1 2 3 4 5 6 7 8 9 A C E F H J
I
n
d
o
o
r
A
Protection
Device Activated
(General)
Faulty Indoor PCB
Abnormal Drain
H2O Level
Abnormal Heat
Exchanger 1
Temperature
Abnormal Heat
Exchanger 2
Temperature
Fan Motor
Overload & Over
Current Lock
Air Swing Motor
Lock
AC Input Over
Current
Faulty Electronic
Expansion Valve
Backup Heater
Thermal Protector
Activated
Booster Heater
Thermal
Protector
Insufcient Water
Supply
Faulty Humidifer
Faulty Or Dirty
Dust Collector
Faulty Capacity
Setting Plug
(Indoor)
C
Flow Switch
Abnormality
Failure of
Transmission
Between Indoor
Unit & Sub PCBs
Faulty Drain H2O
Level Sensor
System
Malfunction
of Liquid Pipe
Thermisor for
Heat Exchanger
Malfunction
of Gas Pipe
Thermisor for
Heat Exchanger
Fan Motor OL/OC,
Lock Sensor Incorrect
combination
Fandrive/Set
Air Swing Motor
Lock Faulty Sensor
System
Faulty AC Input
Current Sensor
System.
Malfunction
of Suction Air
Thermisor
Malfunction of
Discharge Air
Thermistor
Malfunction of
Humidity Sensor
System
Malfunction
of Switch Box
Thermistor
Faulty High
Pressure Switch
Malfunction
of Thermistor
in Remote
Controller
O
u
t
d
o
o
r
E
Safety Device
Activation
(General)
Faulty Outdoor
PCB
Activation of High
Pressure Switch
(HPS)
Activation of Low
Pressure Switch
(LPS)
Activation of
Inverter Compressor
Motor Overload
Compressor Over
Current Lock
Fan Motor OL.OC.
Lock
OC of Inverter
Compressor
Faulty Electronic
Expansion Valve
Malfunction of
4-Way Valve Cool/
Heat Switching
Abnormal Water
Temperature
Faulty Drain H2O
Level System
Faulty Heat
Storage Unit
Pump OC. Lock
Activation Of
Local Safety
Device
F
Activation Safety
Device (Syst.
No.1)
Activation Safety
Device (Syst.
No.2)
Faulty Discharge
Pipe Temperature
Malfunction of
Suction Pipe
Thermistor
Abnormal
High Pressure
or Refrigerant
Overcharge
Expansion Valve
faulty In BSVQ-P
Abnormal
discharge
pressure
Abnormal suction
pressure
Abnormal Oil
Pressure
Abnormal Oil
Surface Level
Abnormal High
Oil Temperature
H
Voltage & Current
Sensor Failure
Faulty Air
Temperature
Sensor System
Damper Fail
Faulty Power
Supply Sensor
System
Faulty High
Pressure Switch
(HPS)
Faulty Low
Pressure Switch
(LPS)
Compressor Motor
Faulty OL. Sensor
System
Compressor Motor
OC. Lock Faulty
Sensor System
Fan Motor OL OC,
Faulty Lock Sensor
System
Faulty AC Input
Power Sensor
System
Malfunction
of Outdoor Air
Thermistor
Malfunction of
Discharge Air
Thermistor
Malfunction of
Domestic Hot
Water Tank
Thermistor
Faulty drain H2O
level Sensor
System
Heat Storage Unit
Alarm
Float switch (local
supply) Open (if
Mode 2-26)
J
Faulty Refrigerant
Temperature
Sensor System
Malfunction of
Pressure Sensor
Faulty Current
Sensor System
Malfunction of
Discharge Pipe
Thermistor
Faulty LP Equiv.
Sat. Temperature
Sensor System
Malfunction of
Suction Pipe
Thermistor
Faulty Heat
Exchanger 1
Temperature
Sensor System
Faulty Heat
Exchanger 2
Temperature
Sensor System
Faulty Liquid
Pipe Temperature
Sensor System
Faulty Gas Pipe
Temperature
Sensor System
Faulty Discharge
Pressure Sensor
System
Faulty Suction
Pressure Sensor
System
Faulty Oil Pressure
Sensor System
Malfunction of
Oil Level Sensor
or Heating HeatX
thermistor
Faulty Oil
Temperature
Sensor System
L
Faulty Inverter
System
Malfunction of
Inverter PCB
Abnormal
Temperature Rise
In Switch Box
Abnormal
Temperature Rise
Radiation Fin
Thermistor
Inverter
Instantaneous OC
(DC output)
Inverter
Instantaneous OC
(AC output)
Inverter
Compressor OC
Detection
Compressor Stall
Prevention
Faulty power
transistor
Malfunction of
Transmission
Between Control
& Inverter PCB
P
Gas Short. ice
thermal stor. Eqp.
Missing Phase.
Unbalanced
Power Supply
Auto charge
Stopped At Step 5
BS4 Not Pushed
Malfunction of
Thermistor in
Switch Box
Faulty Radiant
Fin Temperature
Sensor System
Faulty DC Current
Sensor System
Faulty AC or DC
Output Current
Sensor System
Malfunction
of Total Input
Current Sensor
Autocharge
Should Be
Restarted
Autocharge
Judgement:
Finished OK
Replace Charge
Cylinder Master
Replace Charge
Cylinder Slave 2
Auto charge
Almost fnished
Leak Test not poss
w/o input add
charge
Replace Charge
Cylinder Slave 1
Faulty Capacity
Setting Plug
(Outdoor)
S
y
s
t
e
m
U
Shortage of
Refrigerant
Reversed or Open
Phase Connected
Faulty Power
Supply Voltage
System
Faulty
Transmission
or Test Run Not
Executed
Faulty
Transmission
Indoor
Outdoor Units
Faulty
Transmission.
Indoor Unit
Remote Control
Faulty
Transmission
Indoor Units
(Master
Slave)
Malfunction of
Transmission
between Outdoor
Units
Faulty
Transmission
between Remote
Controllers
Malfunction of
Transmission
between Indoor/
Outdoor Unit in
Same System
Faulty On Site
Setting
Address
Duplication or
Incorrect Setting
Faulty
Transmission
Indoor Unit
Centralised
Control
Incorrect Wiring/
Piping (Wiring/
Piping Connection
Error)
Indoor/Outdoor
unit address not
entered
Fault
communication
to/from
peripheral
equipment
M
Malfunction
of Centralised
Remote Controller
PCB
Malfunction of
Transmission
Optional Controller
for Centralised
Control
Improper Comb.
of Optional
Controllers for
Centralised
Control
Address
Duplication /
Improper Setting
O
t
h
e
r
6
HRV External
Protection Device
Activated
Faulty PCB
Abnormal Ozone
Concentration
Faulty dirt sensor
Malfucntion of
Thermistor for
Indoor Air HRV
Malfunction of
Thermistor for
Outdoor Air HRV
Malfunction of
Damper System
HRV
Humidifer
Element
Replacement
Replace the
Deodorising
Catalyst
Simplifed
Remote Control
Malfunction HRV
Door Switch
Open HRV
Replace High-
Efciency Filter
7
System no. 2
Compressor
Overheat
System no. 2
Compressor Over
Current
System no.2
Fan Motor Over
Current
System no. 2
Activation of HP
Switch
System no. 2
Activation of LP
Switch
System no. 2
Malfunction of LP
sensor
System no. 2
Malfunction of HP
sensor
System no. 1
Malfunction of Fan
Interlock (defect of
relay contact)
System no. 2
Malfunction of Fan
Interlock (defect of
relay contact)
System no. 2
Malfunction
of Compressor
Current Sensor
Malfunction of
Pump Interlock
Flow Failure
Insufcient Water
Flow
8
Inlet Water
Temperature
Thermistor
Outlet Water
Temperature
Thermistor
System no. 1
Malfunction
of Refrigerant
Thermistor
System no. 2
Malfunction
of Refrigerant
Thermistor
System no. 1
Malfunction of
Heat Exchange
Thermistor
System no. 2
Malfunction of
Heat Exchange
Thermistor
System no. 1
Malfunction of
Discharge Pipe
Thermistor
System no. 2
Malfunction of
Discharge Pipe
Thermistor
Heat Exchanger
Freeze Up
Malfunction of
Leaving Water
Temperature
Thermistor
System no. 1
Malfunction of Suction
Pipe Thermistor 1 for
Heating
System no. 1
Malfunction of Suction
Pipe Thermistor 2 for
Heating
Outlet Water
Temperature
Thermistor
9
Low Water
Volume Detection
System no. 2
Defect of EEV Coil
System no. 2
Defect of Suction
Pipe Thermistor
Malfunction of
Transmission
HRV Indoor
Fan Units
System no. 1
Malfunction
of Fan Inverter
System
System no. 2
Malfunction
of Fan Inverter
System
Defect of Thermal
Storage Unit
Thermal Storage
Unit Brine
Pump O/C
Thermal Storage
Brine Tank Low
Water Level
System no. 2
Malfunction of Suction
Pipe Thermistor 1 for
Heating
System no. 2
Malfunction of Suction
Pipe Thermistor 2 for
Heating
Caution: Some displayed malfunction codes may have another meaning. Consult the relevant service manual for details.
Integrated Solutions
M
i
s
c
e
l
l
a
n
e
o
u
s
114
Delivery Information
Notes:
Weekday = Monday to Friday
8:00am to 17:00pm
Standard delivery vehicle is 17.5
ton lorry or smaller with tail lift
Amendment or cancellation
after order entry deadline my be
subject to additional costs
Time specifc is a requested
delivery time plus or minus
30 mins
Delivery address, site contact
name and number are provided
and any delivery restrictions must
be communicated prior to order
entry deadline
95% of mainland UK deliveries =
next day
Postcodes with 2-3 days
transportation lead-time attached
in appendix 1 (Isle of Wight =
2 day transportation lead time)
Driver is not permitted to make
part delivery against a delivery
note. Additional charges may
apply for refused deliveries
Material Code Description Cost Order processing deadline
Standard Delivery Mon - Fri 8:00am to 17:00pm (excluding Spares)
Standard
delivery
Standard delivery Included Order processed by 14:00 Day 1 Delivery Day 2
Standard Hours (8:00am - 17:00pm) Timed Deliveries (excluding Spares)
UK.DLVWIN1 8:00am - 13:00hrs weekdays 50.00 Order processed by 14:00 Day 1 Delivery Day 2
UK.DLVWIN2 12:30 - 17:00hrs weekdays 45.00 Order processed by 14:00 Day 1 Delivery Day 2
UK.TDN_30min Time specifc 30 min window during standard hours 220.00 Order processed by 14:00 Day 1 Delivery Day 2
Outside Standard
UK.TDO_30min Time specifc 30 min window outside standard hours 290.00 Order processed by 14:00 Day 1 Delivery Day 2
UK.RUSH Same day delivery (geographical restrictions apply) 220.00 Order processed 11:00
Weekend Deliveries excluding Spares
UK.TDO_30min Time specifc 30 min window outside standard hours 290.00 Order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested)
UK.SAT_Courrier Less than 15KG 35.00 Order processed by 14:00 Day 1 Delivery Day 2
UK.SAT_Sub Greater than 15KG 110.00 Order processed Day 1 Delivery Day 3
Public holidays - request for deliveries on public holidays are considered on an individual basis
Special Vehicles Standard Delivery Monday to Friday
UK.Special Hiab (includes time slot) 340.00 Order processed by 14:00 Day 1 Delivery day 3
Flat bed (includes time slot)
UK.Van Transit van (size restrictions) 100.00 Order processed by 14:00 Day 1 Delivery Day 2
Special Vehicles Weekends
UK.Special Hiab (includes time slot) 340.00 Order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested)
Flat bed (includes time slot)
UK.Van Transit van (size restrictions) 100.00 Order processed by 14:00 Day 1 Delivery Day 2
Public holidays - request for deliveries on public holidays are considered on an individual basis
2 DAY TRANSPORTATION LEADTIME = UKCFU2
AB BT HS IM IV KA KW PA PH ZE
3 DAY TRANSPORTATION LEADTIME = UKCFU3
GY HS JE KW ZE
Price List 2013 115
M
i
s
c
e
l
l
a
n
e
o
u
s
Units & Accessories: 10 working days from invoice
Spare Parts: 1 month from date of invoice
Goods Returns Procedure
Daikin UK policy for acceptable returned goods
Daikin may accept unwanted goods provided they are boxed
in the original packaging, in perfect condition and have
not been used. To arrange the process of returning goods,
please complete a Goods Returns Form available from
www.daikin.co.uk/business-partners/trade and send by fax
or email to the following:
Units & Accessories:
Fax: 0845 641 9150 or email: returns@daikin.co.uk
Spare Parts:
Fax: 0845 641 9299 or email: spares@daikin.co.uk
Conditions of Returned Goods
All returned items are subject to a minimum 20% restocking/
administration charge with the following collection charges
applied to the nal credit:
Collected goods up to 15KG: 15
Collected goods over 16KG: 90
All returned goods will be fully inspected by our technical
engineers. If returned goods are a non-satisfactory condition
then Daikin reserve the right to decline the return or apply an
increase to the restocking charge.
Damaged Items
We cannot accept claims for damages unless the goods are
signed for as damaged on the delivery note and notication is
received within 3 working days. Any damage identied can be
refused at point of delivery.
What Happens Next
Once the returned goods form is received, an email will be
sent to the conrmation email address provided notifying you of
the goods for collection and a date for this to be carried out.
If you have any queries regarding this date please respond to the
email address provided as soon as possible.
Once inspected and conrmation is received that the goods
are in perfect condition, a credit will be raised against the
original invoice.
*Please note returns for chillers and made to order units will not be accepted*
Goods Covered by Warranty
Once a unit has been installed and commissioned, any faults or
breakdowns that occur these should be reported to our warranty
department on:
Telephone: 0845 641 9275 or email: warranty@daikin.co.uk
Daikin UK policy for acceptable returned goods are as follows:
Integrated Solutions
M
i
s
c
e
l
l
a
n
e
o
u
s
116
Aftersales Technical Helpdesk
This invaluable service oers technical support and guidance
when you are experiencing on-site problems commissioning
or diagnosing faults. Final diagnosis is the responsibility of the
site engineer.
Your calls will be answered by Daikin trained engineers. To help
provide a quick and ecient response please make sure you
have the full model number of the unit. It is important to remind
you that using the D1/D1+ PIN number gives you priority access
to our engineers.
You can access this service Mon Fri 8.30 -5.30pm
Tel 0845 641 9200
Fax 0845 641 9299
Email technicalhelp@daikin.co.uk
SMS Fault Code Service 07797 801908
If you need an explanation and remedy on a fault code and
havent got your service manual, just send the fault code to our
SMS message service and we will advise you by return.
Field Service
We can provide eld engineers to assist you on-site for
commissioning or service intervention. All work is documented
in a report and sent for your records. Since we are working on
your site on your behalf it is essential that you are in attendance
at that time.
To book an engineer contact us on:
Tel 0845 641 9229
Email eldservice@daikin.co.uk
Workshop
In our workshop on the outskirts of Bristol we modify standard
Daikin equipment to current specications that meet our
clients needs. The modications include weatherised vams,
oor mounted fan coil conversions, strip and rebuild to name
a few. Think of the savings in time and money by having your
next VRV outdoor unit delivered to site in sections for placing
in position on the roof, saving at the cost of cranes and road
closure applications. Speak to your sales representative for more
information on what is available.
Spares
When a component fails, eld expertise is pointless unless you
have quick access to spares. Daikin have over 12,000 parts based
in the UK, supported by our European parts centre with 600,000
parts. This helps us to achieve our target of providing 95% of
critical A parts within a 2 day delivery.
To contact the spares team directly
Tel 0845 641 9230
Fax 0845 641 9299
Email spares@daikin.co.uk
If you hold a direct account with Daikin UK, you can send
your spare parts order to us directly using our Spares
Parts Bank. This is available 24 hours a day 365 days a year,
and allows you to view and order your parts online at any
time of day. Plus, all orders processed through Spares Parts
Bank have no delivery charge, which is equivalent to almost
5% extra discount.
To register for Spares Parts Bank go to
www.daikin.co.uk/spares.
The Field Quality Service department (FQS)
The Field Quality Service department (FQS) supply a range of services to support the installer.
Price List 2013 117
M
i
s
c
e
l
l
a
n
e
o
u
s
Daikin UK commercial warranty
If you have a component failure and it is within the warranty
period then we are here to help. After you have spoken to our
helpdesk to conrm diagnosis, you can simply contact the
warranty team.
Contact the warranty team on:
Tel 0845 641 9275
Fax 0845 641 9298
Email warranty@daikin.co.uk
You can also process your claim online at the warranty section of
the Extranet. Here you will nd process claim forms and our full
warranty terms.
The following sets out the Daikin Airconditioning UK Ltd
(Daikin UK) current warranty policies:
Standard warranty is 3 years parts and labour
Daikin ofer 5 years plus double labour allowance to
D1 /D1+ approved installers
Within the warranty period, products are guaranteed against
manufacturing faults in material and workmanship. Replacement
parts will be supplied free of charge, together with a xed labour
allowance, as set out in the table below, provided the correct
procedures are complied with.
The warranty policies are subject to the
following conditions:
The Daikin equipment is installed commissioned and
maintained throughout by a suitably qualied and
certicated refrigeration engineer, and in accordance with
the manufacturers recommendations
The engineer has attended a Daikin Training course relevant to
the equipment being installed
Repeat warranty replacements will be subject to investigation
by the manufacturer
Daikin products that are relocated from their original
installation are excluded
Normal wear and tear is excluded
Procedure:
Daikin UK receive a claim for warranty replacement: dispatch
parts, together with warranty forms, returns documentation
and invoice
The warranty forms must be returned to Daikin UK within 14
days. Faulty parts must be available for collection by Daikin UK
for up to 60 days
Daikin UK receive correctly completed claim form (and faulty
parts if required) and then issue the appropriate credit or
technical rejection
Any claim submitted thirty (30) days after invoice date WILL
NOT be considered for credit
Any claim not submitted in accordance with our procedures
WILL NOT be considered for credit
Payment for warranty claims will only be made by credit note
Any additional cost associated with the replacement of the
actual warranty part (i.e. any cost not itemised in the list of
allowances, travel, refrigerant, waiting time, access equipment)
will be disallowed by Daikin UK
Throughout the warranty period maintenance records must be
kept and available for inspection upon request
General Components 3 year allowances 5 year allowances
A1 Replacement of components within refrigeration circuit 52.00 104.00
A2 Repair of internal pipework (does not include installation pipework) 28.00 56.00
A3 Replacement of air supply fan motor (evaporator and condenser fan motor) 20.00 40.00
A4 Replacement of fan blade 16.00 32.00
A5 Replacement of electrical/electronic components 16.00 32.00
A6 Replacement of condensate drain lift up mechanism 12.00 24.00
A7 Replacement of auto swing louvre motor 12.00 24.00
A8* Dead on arrival of unit (packaged type) 40.00 80.00
A9* Dead on arrival of unit (split type) 72.00 144.00
* Note: A8 & A9 will be single payment if unit is returned without any repairs
Compressors Size 3 year allowances 5 year allowances
B1 < 2.5 HP 84.00 168.00
B2 2.5 HP < 5 HP 100.00 200.00
B3 5HP < 10 HP 150.00 300.00
B4 10 HP < 20 HP 200.00 400.00
B5 25 HP < 50 HP 260.00 520.00
B6 50 HP < 100 HP 360.00 720.00
B7 100 HP > 480.00 960.00
Daikin UK reserve the right to update this warranty (and its terms and conditions), from time to time, without notice.
Integrated Solutions
M
i
s
c
e
l
l
a
n
e
o
u
s
118
Latest range of products
Courses are available to attend at Bristol, Woking, Birmingham,
Manchester and Glasgow. The Daikin UK regional training centres
are fully equipped with the latest range of products, installed and
fully operational for maximum hands on experience.
All training is given by highly skilled engineers who will be
able to provide you with extensive in depth knowledge of our
equipment. If you have any specic training requests outside of
the scheduled programme, please contact us.
A general overview of the style of course
content ofered:
1. Installation and commissioning requirements
2. Advanced service and fault nding for eld engineers
3. Product selection and application techniques
4. Daikin centralised control systems application
and commissioning
Daikin UK training centres
Bristol
Daikin Airconditioning UK Limited
Maple House, Brotherswood Court,
Great Park Road, Almondsbury,
Bristol BS32 4QW
Woking
Daikin Airconditioning UK Limited
1 River Court, Albert Drive, Woking,
Surrey GU21 5RP
Birmingham
Daikin Airconditioning UK Limited
Unit 8, Holly Park, Spitfire Road,
Birmingham, West Midlands B24 9PB
Manchester
Daikin Airconditioning UK Limited
17b Cobra Court, Blackmore Road,
Manchester M32 0QY
Glasgow
Daikin Airconditioning UK Limited
Unit 2, Glasgow Airport Business Park,
Marchburn Drive, Paisley PA3 2SJ
1
3
4
5
2
To book a place on one of the customised product training courses please go to
Daikins new booking site: www.daikintraining.co.uk
Please note: places can only be booked via the website booking system.
Daikin UKs customised product training
Designed to raise standards, set industry benchmarks and help you develop both product and service
expertise. Youll receive the highest quality training and hands on instruction at our industry leading
technology centres.
Price List 2013 119
M
i
s
c
e
l
l
a
n
e
o
u
s
With Daikin UKs support, specialist further education colleges around the UK are oering high-class
training with state-of-the-art equipment. We are committed to helping raise industry standards,
for the highly skilled engineers who are in increasing demand.
Growth together
Daikin UK is committed to ensuring that the next generation
of heating, air conditioning and ventilation engineers has the
specialist skills and practical experience required to install and
maintain the innovative new technologies that can improve
the performance of HVAC-R systems while reducing their
environmental impact.
In turn, this will help employers who invest in apprenticeships and
ongoing training of their engineers to capitalise on the growing
business opportunities for companies with proven expertise in
delivering highly energy-ecient climate control systems.
Why invest in training on the latest systems:
> The rapidly growing market in heat pumps and heat reclaim
systems oers major new business opportunities
> New technologies require wider knowledge of heating,
refrigeration and safe handling techniques
> Tighter regulations demand certifed skills and renewal of
existing certications
> Specialist training programmes provide invaluable hands-on
experience in the very latest technologies
> Market leading technology within a specialist training course
provides the best grounding to develop your teams expertise
College collaborations
So far, this ongoing initiative has created the following
collaborations with Daikin UK:
City of Bath College
College of North West London
Dudley College
West Sufolk College
PGL Training, Exeter
Courses now available around the UK
1
2
3
4
5
Each college oers carefully prepared training courses.
For more information, please contact your local college directly.
Integrated Solutions
M
i
s
c
e
l
l
a
n
e
o
u
s
120
Daikin Airconditioning UK Ltd are a supplier of air conditioning equipment.
The prices shown within this trade price list are for use by qualied installers who agree that:
1 Any equipment purchased is installed by suitably qualied engineers and to the standards expected by
Daikin all in accordance with Daikin installation instructions.
2 The purchasing installer is able to maintain, troubleshoot and carry out warranty repairs in accordance with
the Daikin Airconditioning warranty policy.
Terms and Conditions
All prices shown within this price list are 0.00 net exclusive of VAT and are subject to our standard terms and
conditions which can be found at the back of this price list, and can also be accessed from our website.
Specications are subject to change without prior notice.
1. Defnitions
Seller means Daikin Airconditioning UK Limited, registered in England and Wales with
company number 04616794 trading as Daikin Airconditioning UK Ltd, and shall be
construed where applicable to include all employees, agents and subcontractors of
that company;
Buyer means the person, partnership or company purchasing the Goods from the Seller;
Goods means the plant, machinery, materials, items and labour to be supplied by the
Seller subject to this Conditions; and
Site means such place to which the Buyer shall request the Seller to make delivery.
2. Governing Conditions
2.1 All orders, however made, are accepted only upon these Conditions which shall
override any terms or conditions incorporated or referred to by the Buyer in writing,
orally or otherwise. No variation of these Conditions shall be incorporated into the
contract between the Seller and the Buyer unless expressly accepted in writing by a
director of the Seller.
2.2 No failure by the Seller to object to any terms or conditions incorporated or referred
to by the Buyer in writing, orally or otherwise shall be deemed a waiver of these
Conditions or an acceptance of the Buyers terms and conditions.
2.3 The Buyer acknowledges that these Conditions together with the express terms
of the contract constitute and form the entire terms of this contract to the exclusion
of any antecedent statement or representation whether oral, written or implied or
whether contained in any advertisement particulars or other matters issued or in any
correspondence entered into by the Seller. The Buyer further acknowledges that it has
not entered into this contract in reliance upon any such statement or representation,
other than the written specications given by the Seller.
3. Placing Orders
3.1 Placing an order presumes knowledge and acceptance of these Conditions. Upon
placing an order the Buyer shall receive an acknowledgement of the order in writing
and/or through the online order system designated by Seller, if any; which does not
constitute a binding contract until the Seller accepts the Buyers order by written
conrmation and/or through such online system, as the case may be.
3.2 The Seller reserves the right to reject cancellation by the Buyer of an accepted
order or any portion thereof. Cancellation of an accepted order needs to be approved
in writing or through the online system designated by Seller, as the case may be by the
Seller and the Buyer may be charged cancellation charges. Goods already delivered
cannot be returned or exchanged and will be invoiced.
3.3 Changes to an accepted order shall be treated as a separate order, unless otherwise
agreed in writing by the Seller. If any changes are made to an original order, the price,
discount on or delivery date of that order are subject to change.
3.4 The Seller has a policy of continuous technical improvement and accordingly
reserves the right to make minor modications to the technical specication and
design of the Goods. Catalogues and similar publications are only sent by way of
information and any technical information provided is an approximate guide. The Seller
has no liability for any deviations from or mistakes in such information or for any errors
of interpretation.
4. Price and Payment
4.1 The Sellers quotation, unless previously withdrawn or revised in writing or through
the online system designated by Seller, as the case may be, is valid until the end of the
nancial year (31st March) (after which time it shall automatically expire) and is subject to
the Sellers acceptance of the Buyers order. The Seller reserves the right to amend their
prices during the nancial year and any such changes will mean previous quotations
(prior to the price change) are only valid for 30 days, from the date of the quotation.
4.2 The Sellers quotation includes only such goods, accessories and work as are
specied thereon and (without limitation to the foregoing) does not include the cost
of lighting, power, heat and water required and/or used during the installation and
testing of the Goods at the Site, or any insurance or overtime working by the Seller.
4.3 The price quoted for the Goods is based on the cost to the Seller at the date of
quotation of materials, labour, transport and all other expenses and of conforming
to any statutory regulations. The Seller reserves the right to vary the quoted price to
take account of any variation (including variations caused by alterations in rates of
exchange) in the aforesaid costs between the date of the quotation and the date of
actual physical delivery of the Goods.
4.4 All amounts stated in these Conditions to be payable by the Buyer are exclusive
of Value Added Tax or any similar tax properly chargeable in respect of supplies under
these Conditions and any other tax or duty and Buyer will pay all such Value Added Tax
and other applicable taxes together with those amounts.
4.5 Each payment made by the Buyer must be calculated and made without, and free
and clear of any deduction for set-o or counterclaim and any withholding for or on
account of any tax or any other deduction, unless required by law, in which case the
Buyer shall ensure that the withholding or deduction does not exceed the minimum
amount required by law and shall increase the amount payable by it so that the net
amount received and retained by the Seller will equal the full amount which Seller
would have received and retained if no withholding or deduction had been made.
4.6 Unless otherwise agreed in writing, the Buyer shall pay the invoice amount of the
Goods and any other costs, charges or expenses provided for by these Conditions
including Value Added Tax at the then current rate within 30 days from the date of
the Sellers invoice in immediately available funds, but the Seller reserves the right to
require payment before delivery or installation.
4.7 Time for payment shall be of the essence of the contract. Any invoice not paid in
accordance with the foregoing shall be liable to interest on the unpaid amount thereof
at the rate of 3% per annum above the base rate from time to time of Barclays Bank plc
calculated on a day to day basis.
5. Delivery
5.1 Failure by the Seller to make delivery on any particular date shall not entitle the
Buyer either to cancel the order or the delivery or to repudiate this contract or to claim
for any expenses, loss of prot, or any other consequential loss or damage whatsoever.
5.2 If the contract provides for the Seller to deliver the Goods, delivery shall be deemed
to take place when the Goods arrive at the agreed destination or are ready for despatch
by the Seller to the order of the Buyer and such despatch shall have been delayed by
the Buyer, whichever is the sooner.
5.3 The Buyer undertakes that the Site will at all times be safe for the Seller and its
vehicles carrying out delivery. The Buyer is responsible, at its own cost, for the provision
of such labour and apparatus as is necessary for the ooading and positioning of the
Goods on Site and shall give the Seller every assistance in eecting delivery.
5.4 If the contract provides for the Goods to be collected by or on behalf of the Buyer,
the Seller shall give the Buyer reasonable notice in writing and/or orally of when and
where Goods will be ready for collection. Delivery shall be deemed to take place upon
the date and at the place so notied whether or not the Goods are so collected.
5.5 The Seller may deliver the Goods in instalments and each such instalment shall
be deemed to be the subject of a separate contract and no damage, non-delivery or
shortage in relation to any such instalment shall entitle the Buyer to any remedies in
relation to any other instalment or contract. If payment of any instalment is not made
in accordance with clause 4, the Buyer shall be liable to the Seller for any costs incurred
in connection with manufactured or partly manufactured Goods acquired by the Seller
for the Buyer, in addition to the other rights and remedies available to the Seller.
Price List 2013 121
M
i
s
c
e
l
l
a
n
e
o
u
s
6. Risk
6.1 Risk shall pass to the Buyer on delivery of the Goods.
6.2 If delivery does not take place as a result of any act or omission of the Buyer or if the
Buyer fails to collect the Goods as set out in clause 5, then delivery shall be deemed to
have taken place and risk shall pass to the Buyer, who shall indemnify the Seller in full
against any expense, cost or loss incurred by the Seller including, without limitation,
storage and transport costs.
6.3 The Buyer shall examine any Goods delivered upon delivery. If the Goods or any
part thereof are received in a damaged condition or are not received, the Seller will
accept no responsibility for such damage and or loss unless the Buyer advises the Seller
in writing of the damage or loss within 3 working days from the earlier date of actual
physical delivery of the Goods or the date of installation of the Goods (save where the
damage is a latent defect in the Goods in which case clause 17 shall apply). The Buyer
must then aord the Seller reasonable opportunity to inspect any damage or verify any
loss and shall immediately return the damaged Goods to Seller.
6.4 The Sellers sole responsibility upon any damage or loss is to repair or replace
the Goods which prove to be lost or defective (or at the Sellers option the defective
part(s)), as soon as is reasonably practicable, provided that they are returned to the
Seller by the Buyer. Whether the remedy is repair or replacement shall be at the option
of the Seller and such repair or replacement shall be free of charge. Subject to the
provisions of clause 17 the Seller shall have no further liability to the Buyer.
6.5 If the Buyer shall fail to comply with clause 6.3, the Goods shall be deemed to be in
accordance with the contract and the Buyer shall be bound to accept delivery and shall
make payment without any deduction in accordance with these Conditions.
6.6 The Seller will not be liable for any claims resulting from loss or damage to the
Goods occurring after delivery.
7. Force Majeure
7.1 If the Seller is prevented from performing the contract by any cause beyond
its reasonable control, however arising, then it may by written notice to the Buyer
determine the contract.
7.2 In such event, the Buyer shall pay to the Seller all reasonable costs incurred by the
Seller at the date of such notice in relation to its partial and or attempted performance
of its obligations hereunder but, subject thereto, neither the Seller nor the Buyer shall
be under any liability whatsoever to the other in connection with the contract.
8. Shortages
If the Seller is unable, for any reason, to supply the total demand for Goods of the
contract description, the Seller may allocate its available supply of such Goods among
any and all Buyers on such basis as the Seller may deem fair and practical without
liability for any failure of performance which may result. The Buyer shall not be entitled
to reject such Goods for short delivery.
9. Works and Specifcation
9.1 Where existing equipment is to be used in connection with the Goods, the Buyer
shall be fully and solely responsible for it.
9.2 Any adaptation of the standard specication of the Goods shall be made upon
the full and sole liability of the Buyer. Where the standard specication of the Goods
is adapted, whether by the Seller at the request of the Buyer, or by the Buyer itself, the
Buyer agrees to indemnify (and shall keep so indemnied) the Seller in full against any
claim resulting from any such variation (whether or not arising out of the negligence of
the Seller, its servants, agents or subcontractors). In the event of any adaptation made
by the Seller upon request of the Buyer, the Buyer shall make such payment in respect
thereof as the Seller may reasonably demand.
9.3 The Buyer shall be responsible for ensuring that the Goods are sucient and
suitable for the Buyers purposes (whether such Goods have been adapted from their
standard specication or not) and the Seller shall have no liability to the Buyer in the
event that the Goods are not sucient and suitable for the Buyers purposes.
9.4 Unless otherwise expressly agreed in writing, the Seller shall not be responsible for
any errors, omissions or defects in any goods, equipment, machines, parts, drawings,
designs, specications, test results, reports or other information supplied to the Seller
by the Buyer or the Buyers employees, agents, sub-contractors or representatives and
the Buyer agrees to indemnify and keep indemnied the Seller against all claims and
liabilities incurred by the Seller resulting from such errors, omissions or defects.
10. Installation
It is the responsibility of the Buyer to install and commission the Goods and to ensure
its employees, agents and subcontractors or any other persons used by the Buyer to
install and commission the Goods are fully trained to do so and that the terms of any
instructions or manuals provided with the Goods are followed.
11. Health and Safety
The Buyer shall ensure that all Goods shall be used strictly in accordance with any
relevant information, instructions or advice which the Seller or the manufacturer of the
Goods may make available with or in connection with the Goods.
12. Environmental
12.1 The Buyer shall be responsible for all costs, charges, and expenses arising from
or in connection with the decommissioning, recovery, recycling, and disposal of all or
part of the Goods and shall not seek to recover such expenses or contribution from
the Seller.
12.2 The Buyer is responsible for obtaining and complying with all relevant licenses,
permissions, permits and consents from appropriate regulatory bodies and for
complying with any other lawful authority in connection with the storage, installation,
operation, use, maintenance, repair, transportation, decommissioning, recovery and
eventual disposal of the Goods.
12.3 Where the Buyer sells all or part of the Goods to another party, the Buyer shall
enter into a similar covenant with that party.
13. Reservation of Title
13.1 Notwithstanding the provisions of clause 6 and the passing of risk in the Goods
to the Buyer, the Seller retains ownership of the Goods the property in which shall not
pass to the Buyer and the Buyer shall keep any Goods delivered to it as the bailee for
and on behalf of the Seller until the Seller has received payment of the price of all of the
Goods then agreed to be sold by the Seller to the Buyer pursuant to these Conditions,
and until such time the Buyer:
(a) shall keep and retain the Goods free from any charge, lien or other encumbrance,
shall insure them for their full replacement value against any loss or damage and shall
keep them properly stored and protected; and
(b) shall store the Goods separately or in some other way ensure that they are readily
identiable as the property of the Seller and irrevocably authorises the Sellers
representatives to enter upon the Buyers premises where the Goods are or are thought
by the Seller to be stored for the purpose of repossessing them and subsequently
reselling them.
13.2 Notwithstanding the provisions of clause 13.1, provided that none of the
circumstances set out in clause 16 shall apply, the Buyer shall be entitled before the
Seller has received full payment of the price of the Goods to oer for sale and sell the
Goods in the ordinary course of its business (but not otherwise) and the proceeds of
such sale or the Buyers claim for such proceeds shall be held by the Buyer as agent for
the Seller and the Sellers property in the Goods shall be transferred to the proceeds of
such resale or the claim for such proceeds and shall attach thereto until the Seller has
received payment of the price of all of the Goods then agreed to be sold by the Seller
to the Buyer pursuant to these Conditions.
13.3 Save as otherwise stated therein, the provisions of clauses 13.1 and 13.2 shall
survive the termination of any contract made pursuant to these Conditions for
whatever reason and in particular, but without limitation, termination by the Seller by
the acceptance of repudiation of this contract by the Buyer.
14. Intellectual Property Rights
14.1 The Buyer shall have no rights to any intellectual property owned by or licensed
to the Seller. The Buyer shall not allow any trademark or instruction or warning applied
to the Goods to be obliterated or obscured.
14.2 All designs, samples, models, experimental equipment, marketing devices,
accessories and other items relating to the Goods or their development or creation shall
remain the Sellers property, shall be treated as condential and shall not be copied,
reproduced or disclosed to any person without the Sellers prior written consent.
15. Confdentiality
15.1 All information and/or advice, whether written or oral, whether in relation to
the Goods or to the business of Seller, given by the Seller to the Buyer, shall not be
disclosed to any third party without the prior written consent of the Seller, save to the
extent that such information and/or advice is in the public domain otherwise than by
virtue of a breach of this condition or that the disclosure is required by law.
15.2 The Buyer shall promptly give notice to the Seller of any disclosure required by
law and the Seller may seek an appropriate remedy to prevent such disclosure. The
Buyer undertakes to fully co-operate with the Seller (at the Buyers expense) if the Seller
rejects the validity of such a requirement.
16. Early Termination
16.1 This clause applies if:
(a) the Buyer makes any voluntary arrangement with its creditors or becomes subject
to an administration order or (being an individual or rm) becomes bankrupt or
(being a company) goes into liquidation (otherwise than bona de for the purposes of
amalgamation or reconstruction); or
(b) an encumbrancer takes possession, or a receiver is appointed, of any of the property
or assets of the Buyer; or
(c) the Buyer ceases, or threatens to cease, to carry on business; or
(d) any event analogous to any of the foregoing occurs in any jurisdiction in relation
to the Buyer; or
(e) the Buyer commits any default or breach of the terms of this contract or of any
of its obligations to the Seller including, without limitation, failure to make payment
when due; or
Integrated Solutions
M
i
s
c
e
l
l
a
n
e
o
u
s
122
(f ) the Seller reasonably apprehends that any of the events mentioned above is about
to occur in relation to the Buyer and noties the Buyer accordingly.
16.2 If this clause applies then, without prejudice to any other right or remedy available
to the Seller, the Seller shall be entitled to cancel any contract made pursuant to
these Conditions or suspend any further deliveries of the Goods without any liability
on its part, and if the Goods have been delivered but not paid for, the price shall
become immediately due and payable notwithstanding any previous agreement or
arrangement to the contrary.
17. Warranties and Liability
17.1 Subject to clause 17.3 and unless otherwise agreed in writing, the Goods are
guaranteed under manufacturers warranty for a period of 1 year upon delivery. This
warranty is limited to the repair or replacement ex factory of the parts found defective.
Unless otherwise agreed in writing, the Seller shall not be liable for repayment of
replacement costs nor for any incidental, consequential or special damages.
17.2 To claim under the warranty, the Buyer shall submit to the Seller adequate proof
that the Goods are defective, as required by the Seller. Unless otherwise agreed in
writing, claims with regard to the Goods will only be accepted if they are notied within
12 months after delivery of the Goods.
17.3 This warranty is given on condition that the maintenance of the Goods has been
carried out in accordance with the manufacturers instructions by an authorised Daikin
dealer/installer/maintenance company.
17.4 The warranty referred to in clause 17.1 does not apply if:
(a) the Goods have been modied by the Buyer;
(b) the Goods have been incorrectly installed by the Buyer;
(c) defects in the Goods have been caused by the act, neglect, omission or default of
the Buyer or any third party, fair wear and tear or abnormal working conditions;
(d) any remedial work in respect of the Goods has been carried out by third parties
instructed by the Buyer without the prior written approval of the Seller including, but
not limited to, servicing, alteration and repair of the Goods;
(e) if the Sellers installation and operation instructions (if any) and any instructions
issued by the manufacturer, are not followed.
17.5 The Seller only acts in its capacity as seller and not as an installer or consultant
and the Seller is not responsible for advice given by its representatives concerning the
installation of the Goods, save in relation to all or any part of the Goods which the Seller
has installed with the written agreement of an authorised representative of the Seller
(excluding any agent or subcontractor of the Seller) to the installation and to the terms
of such installation for claims.
17.6 Save for liability for death or personal injury due to the negligence of the Seller
and liability under the Consumer Protection Act 1987, the Seller shall not be liable to
the Buyer:
(a) for any damage to persons or property, however arising;
(b) for defects, in or in any way connected with the Goods, caused by the act, neglect,
omission or default of the Buyer or any third party, fair wear and tear or abnormal
working conditions;
(c) for any remedial work in respect of the Goods, carried out by third parties instructed
by the Buyer without the prior written approval of the Seller including, but not limited
to, servicing, alteration and repair of the Goods;
(d) for claims if the Sellers installation and operation instructions (if any) and any
instructions issued by the manufacturer, are not followed. The Seller reserves the right
to charge for remedial works in these circumstances;
(e) possible defects in manufacturing the Goods or the conception of the raw materials
used;
(f ) for any other defects in the Goods not falling within paragraphs (a) to (e) of this
clause, unless notied to the Seller by the earlier of 14 days of delivery of the Goods or
installation of the Goods or occurrence of a malfunction by a latent defect; and
(g) for any special, indirect, consequential or economic loss (howsoever arising)
including, but not limited to, loss of prot, loss of production, loss of business.
17.7 Save for liability for death or personal injury due to the negligence of the Seller
and liability under the Consumer Protection Act 1987, the Sellers aggregate liability to
the Buyer in respect of any occurrence or series of occurrences attributable to the same
cause, whether for negligence, breach of contract, misrepresentation or otherwise,
shall in no circumstances exceed the price paid by the Buyer to the Seller in respect
of the Goods in question.
17.8 The Sellers prices are determined on the basis of the limits of liability set out
in this clause 17. The Buyer may by written notice to the Seller request the Seller to
agree a higher limit of liability provided insurance cover can be obtained therefor. The
premiums in respect of insurance up to such higher limit will be for the account of
the Buyer.
17.9 Subject as expressly provided in these Conditions, all warranties, conditions or
other terms implied by statute, common law, custom of the trade, course of dealing or
otherwise, including, for the avoidance of doubt, all warranties implied by the Sale of
Goods Act 1979, are excluded to the fullest extent permitted by law.
17.10 The Buyers remedy in respect of any claim for which the Seller is liable in terms
hereof shall be limited to, at the sole option of the Seller, repair or replacement of the
item in question or refund of the purchase price (if paid).
17.11 The Buyer shall not be entitled to exercise a right of retention, or withhold
payment of any amount payable under the contract to the Seller because of any
disputed claim of the Buyer in respect of the Goods or any other alleged breach of the
contract, or to set-o any amount payable under the contract to the Seller against any
monies not then presently payable by the Seller or for which the Seller disputes liability,
or to return Goods to the Seller unless authorised in writing by a director of the Seller.
17.12 The Seller shall not be liable to the Buyer (including, but without limitation,
in negligence) or be deemed to be in breach of contract by reason of any delay in
performing, or any failure to perform, any of the Sellers obligations in relation to the
Goods, if the delay or failure was due to any cause beyond the Sellers reasonable
control.
17.13 The Buyer shall indemnify the Seller against all claims (including the cost of any
legal proceedings) for the death of or injury to any person or for the damage to or loss
of any property made by any person against the Seller either under any statute or at
common law which may arise out of or be in any way connected with the execution of
the contracted works or the installation, operation or use of the Goods except where
the same is due to the negligence, omission or default of the Seller.
18. Personal Data
18.1 We will only use any personal data we obtain about you in accordance with the
Data Protection Act 1998. We may use your personal data for the purposes of fullling
your order, providing goods and services to you, managing our relationship with
you, for our internal accounting and processes and for legal or regulatory purposes.
For some of these purposes we may need to share your data with third parties but
we always ensure that your data is kept condential and protected by third parties.
In particular, we may ask credit reference agencies to run credit searches or checks
against you and those registered at your address and we may pass on your information
to these agencies to assess your nancial performance, including sharing our customer
ledger balances. You should be aware that the results of the credit searches or checks
may be added to your credit reference le.
18.2 Sometimes, we may need to transfer your data outside the European Economic
Area to countries which do not have as strong data protection laws as the UK. Where
we do so, we take steps to ensure that your data is protected to the same standard as
in the UK.
18.3 You agree that we and other members of our group and/or selected third parties
may contact you by phone, e-mail or SMS or other messaging service about other
products and services which may be of interest to you. If you do not want to receive
such messages at any time, please let us know and you will no longer be contacted.
19. General
19.1 The invalidity or unenforceability for any reason of any terms of these Conditions
shall not prejudice or aect the validity or enforceability of the remainder.
19.2 The Buyer shall not be entitled, without the prior consent in writing of the Seller,
to assign its rights under the contract.
19.3 Any notice required or permitted to be given under these Conditions shall be
in writing and shall be sent by recorded delivery addressed to that other party at its
registered oce or principal place of business or such other address as may at the
relevant time have been notied pursuant to this provision to the party giving notice.
In proving service it shall be sucient to prove that the notice was properly addressed
and posted.
19.4 No waiver by the Seller of any of the terms of these Conditions shall release the
Buyer from full performance of the remaining terms, and no waiver by the Seller of any
breach of the terms of these Conditions shall be a waiver of any subsequent breach
of the same or any other term of this Conditions. No failure to exercise, nor delay or
omission by the Seller in exercising, any right, power or remedy conferred on it under
these Conditions or provided by law shall except with the express written consent of
that party aect that right, power or remedy; or operate as a waiver of it.
19.5 If any order is made by two or more Buyers jointly, the obligations of those Buyers
under the contract shall be joint and several.
19.6 This Contract shall be governed by and construed in accordance with the laws of
England and any dispute shall be referred to the exclusive jurisdiction of the English
Courts.
19.7 The Seller and the Buyer do not intend that any provision of these Conditions shall
be enforceable by virtue of the Contract (Rights of Third Parties) Act 1999 by any person
who is not a party to the contract.
19.8 We reserve the right, at our sole discretion, to change, modify or otherwise alter
these terms and conditions at any time. Such modications shall become eective
immediately.
your comfort. our world.
Daikin Airconditioning UK Limited The Heights Brooklands Weybridge Surrey KT13 0NY Tel 0845 6419000 Fax 0845 6419009 www.daikin.co.uk
U
K
E
P
C
E
N
1
3
-
9
1
1

/

0
4
.1
3

/

D
e
s
i
g
n
H
Q
.
C
o
p
y
r
i
g
h
t

2
0
1
3

D
a
i
k
i
n
P
r
i
n
t
e
d

i
n

t
h
e

U
K

o
n

F
S
C

c
e
r
t
i
f
i
e
d

p
a
p
e
r

f
r
o
m

s
u
s
t
a
i
n
a
b
l
e

s
o
u
r
c
e
s
.
Visit www.eca.gov.uk/etl and type Daikin in the quick search box
for details of the latest ECA qualifying Daikin units
Daikin products are distributed by:
The present catalogue is drawn up by way of information only and does
not constitute an oer binding upon Daikin UK. Daikin UK has compiled the
content of this catalogue to the best of its knowledge. No express or implied
warranty is given for the completeness, accuracy, reliability or tness for
particular purpose of its content and the products and services presented
therein. Specications are subject to change without prior notice. Daikin UK
explicitly rejects any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of this catalogue.
All content is copyrighted by Daikin UK.
Daikin units comply with the European
regulations that guarantee the safety of
the product.
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
FSC
Carbon
Balanced Paper

You might also like