esserbus FSA transponder for fire doors
808619.10
VdS
Description
The transponder is suitable for usage for various applications: in stand-alone
operation or on the esserbus. In esserbus operation, the Series 9200 automatic fire
detectors and those of the IQ8Quad family (see features for types) can be used as
detectors in door arrester systems (FSA - Fire, Failure and Shut-Off). In FSA
transponder loop operation, the door arrester system status is indicated on the fire
alarm control panel.
For stand-alone operation, detectors of the IQ8Quad family are supported without
loop isolator (see features for types).
For operation, the transponder requires an external supply voltage. It is possible to
monitor this voltage.
Features
Only one loop address is needed per transponder
Usage of series 9200 intelligent detectors (such as OT, OTI, OT detectors) as
FSA detectors is possible
Connection of IQ8Quad O detectors (Part No. 802371), TD Detectors (Part No.
802271), OT detectors (Part No. 802373) and OT detectors (Part No. 802374)
(DIBt-approved) as FSA detectors is possible
FSA detectors programmable as devices in the loop
Status indicator of door arrester system to the FACP
Actuation of the locking device also via the automatic fire detectors in non-FSA
operation
Stand-alone operation of the FSA transponders is possible
Usage of IQ8Quad O detectors (Part No. 803371), TD detectors (Part No.
803271) and OT detectors (Part No. 803374) in stand-alone operation of the FSA
transponders to the standard detector group is possible
Max. 100 transponders per FACP
Max. 32 transponders per analog loop
Max. 127 detector zones per analog loop
Detector numbers per zone input of the transponder:
Max. 30 conventional detectors (without SOC)
Max. 10 conventional detectors (with SOC)
Max. 10 Manual call points
Max. 10 Technical Alarm Modules (TAM/TAL)
Technical Data
Operating voltage 10 ... 28 V DC
Current consumption max. 28 mA (from UB ext)
Quiescent current @ 12 V DC approx. 6 mA (from UB ext)
Contact load relay max. 30 V DC/1 A or 48 V DC/0,5 A
Ambient temperature -5 C ... 50 C
Storage temperature -25 C ... 75 C
Type of protection IP 40 (with housing)
Air humidity < 95 % (non-condensing)
Username
Password
login
Customer Login
Forgot password?
register
Press Area
Are you looking for more information
about our company? Please find all
press publications in our press area.
more

search...
Worldwide Language
ESSER by Honeywell: Details https://www.esser-systems.com/en/produkte/details/transponders/esser...
1 of 2 8/10/2014 9:28 PM
Weight approx. 70 g
Dimensions W: 72 mm H: 65 mm D: 20 mm (PC
Board)
Accessories
788612 Loop isolator PCB
788603.10 Module housing for C-mounting bar or top hat rail mounting
788600 Housing surface mount, gray
788650.10 Housing surface mount, white
788601 Housing flush mount, gray
788651.10 Housing flush mount, white
808625 EOL-Z
Additional information
Corresponding connection examples for FSA transponder operation in stand-alone
operation or as a device in the fire detection System 8000 can be found in the
chapter containing automatic door release systems.

Legal Notice Privacy Statement Sitemap Copyright Honeywell International Inc 2005-2014
ESSER by Honeywell: Details https://www.esser-systems.com/en/produkte/details/transponders/esser...
2 of 2 8/10/2014 9:28 PM

You might also like