Professional Documents
Culture Documents
Pump Hand operated and small Air PMB-1 • Both mounting brackets
Mounting Pumps; P-80, P-84, P-142, are pre-drilled to accept
Bracket P-392, PA-133, Turbo II pumps a number of different
pump models
Electric, large Hand Pumps, and PMB-2
ZA4 Air Pumps; ZE Series,
P-462, P-464, 10/90 Series
Air Pumps
Cylinder Speed
This chart will help you calculate the time required for an Enerpac cylinder to extend when powered by a 10,000 psi Enerpac
hydraulic pump. The Cylinder Speed Chart can also be used to determine the pump type and model best suited for an application
when you know the plunger speed required.
Cylinder and Pump Selection Chart
Cylinder Cylinder Hand Operated Pumps Electric Pumps Air Pumps
Capacity Load
Strokes per inch of plunger travel Seconds per inch of plunger travel
No load 1,7 7,8 11,3 87,5 38 28 85,1 122,9 160,7 12 7,6 123 161
10 (89)
Load 1,7 1,7 1,7 3,3 3,8 3,8 7,6 11,3 22,7 1,5 1,5 1,7 5,7
No load 0,7 3,4 4,9 38,0 17 12 36,9 53,3 69,7 5,3 3,3 53 70
25 (223)
Load 0,7 0,7 0,7 1,4 1,6 1,6 3,3 4,9 9,8 0,7 0,7 0,7 2,5
No load 0,6 2,7 3,9 30,1 13 2,1 29,3 42,3 55,3 4,2 2,6 42 55
30 (267)
Load 0,6 0,6 0,6 1,1 1,3 1,3 2,6 3,9 7,8 0,5 0,5 0,6 2,0
No load 0,3 1,6 2,3 17,7 7,7 5,8 17,2 24,9 32,5 2,5 1,5 25 33
50 (445)
Load 0,3 0,3 0,3 0,7 0,8 0,8 1,5 2,3 4,6 0,3 0,3 0,3 1,1
No load 0,2 0,8 1,2 9,5 4,1 3,1 9,2 13,3 17,4 1,3 0,8 13 17
100 (890)
Load 0,2 0,2 0,2 0,4 0,4 0,4 0,8 1,2 2,5 0,2 0,2 0,2 0,6
Note: Values are approximate. Cylinder speed may vary in actual application.