You are on page 1of 2

Brief description:

Toshiba detector FDX 4343R for excellent


image quality with low X-ray dosage
Sensor: very high sensitivity
and high dynamic range
CSI screen
Response time: no time
delay for the release of the
X-ray shot (compared to
other flat panel systems)
when you press the hand
release the X-ray shot is
released immediately
Fast exchange: In case of a
defect, OR Technology
guarantees to deliver a
replacement panel within
four days (no further costs,
only transport costs will be
incurred)
Guarantee : 2 years, may be
extended to 4 years
The new Toshiba flat panel FDX 4343R is supported by the release of
version 1.9. The CsI-based flat detector provides high
resolution and outstanding image quality. A DQE value of 70% guarantees
high contrast and low noise coupled with a low dosage requirement. After
only a few seconds the detector is ready for operation again.
Type: Cesium Iodide (CsI) with Amorphous
Silicon (a-Si) Photodiode
Active Area: 16.9 x 17.3 inch
Pixel Matrix: 3008 (H) x 3072 (V)
Pixel Pitch: 143 m
Cycle Time: Shot to shot 6sec.
Limiting resolution: 3.5 Lp/mm
MTF (2.0 lp/mm, 70kVp, 1x1): 30 % typ.
DQE: > 70%
A/D Conversion: 14 bit
40 125 kVp
4 mR / frame
dicom DX-R PACS

Image format
Performance:
Energy Range:
Maximum entrance dose:

Technical data:
R Technology
Digital X-ray and
Imaging Solutions
a
n
d
O
Product Information
V
e
r
s
i
o
n

0
0
1
_
0
4
_
2
0
1
0
P
r
o
d
u
c
t

i
n
f
o
r
m
a
t
i
o
n
OR Technology (Oehm und Rehbein GmbH), Waldemarstrae 20 g/h, 18057 Rostock,
Germany, Tel. +49 (0)381 - 20 36 126, info@or-technology.com, www.or-technology.com
Toshiba detector FDX 4343R for excellent
image quality with low X-ray dosage
Flat panel
Active area:
16.9 x 17.3 inch
42.9 x 43.9 cm
Power supply unit
5
1
.2
cm
4
9
.5
c
m
4.3 cm
OR Technology (Oehm und Rehbein GmbH), Waldemarstrae 20 g/h, 18057 Rostock,
Germany, Tel. +49 (0)381 - 20 36 126, info@or-technology.com, www.or-technology.com
Specifications subject to revision without notice
The editor strives to impart correct and up to date information. The
provided specifications are based on current knowledge and are subject to
revision without notice. This brochure is subject to correction. The editor
assumes no responsibility for the information being up to date, correct
and complete.
All furnished logos, pictures and graphics are property of the particular
company and subject to copyright of the licensor. Use, dissemination,
distribution or copying of the pictures, logos or text compiled or processed
by the editor is subject to our written consent. All rights reserved.

You might also like