FIRE ALARM

PRODUCT CATALOGUE 2012

Contents Page
1. Introduction
2. Business unit detectomat
3. International sales contact

4
5
6

4. FIRE ALARM SYSTEMS


4.1 Fire control panel dc3400 SC and accessories
4.2 Fire control panel detect 3004plus and accessories
4.3 Software and tools for fire alarm systems
4.4 Visual detect, software for loop3000
4.5 Addressable automatic detectors for loop3000 and accessories
4.6 Addressable manual call points for loop3000 and accessories
4.7 Addressable input/output modules for loop3000 and accessories
4.8 Addressable signalling devices for loop3000 and accessories

7
9
11
26
28
30
38
41
44

5. CONVENTIONAL SYSTEMS
5.1 Fire control panels, conventional
5.2 Detectors CT 3000 series, conventional
5.3 Signalling devices optical/acoustic, conventional

48
49
52
59

6. Special detectors and accessories



7. VOICE EVACUATION SYSTEMS
7.1 Voice evacuation system sound detect

62

8. DOOR HOLDER SYSTEMS


8.1 Accessories for door holding systems

83
84

9. RMA conditions (Return Material Authorisation)


10. Price list for spare parts and discontinued articles
11. General terms and conditions

94
95
96

74
75

1. Introduction

Dear Business Partner,


welcome to the detectomat catalogue for fire
alarm system technology.
This catalogue gives an overview about our entire
product range consisting of fire alarm systems,
wireless systems, door control systems and voice
evacuation systems.
Our innovative products and numerous patents
allow a flexible use in many fields of application in
the fire detection. Based on the efficient research
and development, production and quality
assurance of our worldwide operating company
we can offer high technology and customer
oriented products in an attractive design.
The integration of special measuring methods and
Voice evacuation systems
algorithms for the analysis of characteristic
parameters result in products with a fast and
reliable reaction on fires and a high resistance
against false alarms.
Following our philosophy No compromise
in safety, we would like to increase the safety
together with you.
We wish you great success in your projects and
are looking forward for a pleasant cooperation.

Fire alarm systems

Door holding systems

Wireless systems

2. Business unit detectomat

Technical Hotline:
Hotline international

Tel.: +49 (0) 4102 2114-691


Fax: +49 (0) 4102 2114-9670

E-Mail: hotline@detectomat.com

Please mention your customer number at enquiry:

Business unit detectomat:


Director Sales:
Mike Bohl

Tel.: +49 (0) 4102 2114-639


Fax: +49 (0) 4102 2114-670

E-Mail: bohl@detectomat.com

Order Processing:
E-Mail:

zkm.sales@detectomat.com
Fax: +49 (0) 4102 2114-670

Silke Schotte
Anja Rupschuss
Philipp Lahann

Tel.: +49 (0) 4102 2114-637 E-Mail: schotte@detectomat.com


Tel.: +49 (0) 4102 2114-662 E-Mail: rupschuss@detectomat.com
Tel.: +49 (0) 4102 2114-661 E-Mail: lahann@detectomat.com

detectomat GmbH
An der Strusbek 5
22926 Ahrensburg

Tel.: +49 (0) 4102 2114-60


Fax: +49 (0) 4102 2114-670

Trade Register: 10565 HL

E-Mail: info@detectomat.com
www.detectomat.com

3. International Sales Contact

Director Sales

Western Europe

Northern Europe, Eastern Europe

Mike Bohl

Jens Mller

Karl-Heinz Rohr

An der Strusbek 5
22926 Ahrensburg
Tel.: +49 (0) 4102 2114 639
Fax: +49 (0) 4102 2114 670
Mobil: +49 (0)171 5679909
bohl@detectomat.com

Tel.: +49 (0) 37367 86 0 95


Fax: +49 (0) 37367 86 1 77
Mobil: +49 (0) 170 452 2091
jmueller@detectomat.com

Tel.: +49 (0) 4102 2114 60


Fax: +49 (0) 4102 2114 670
Mobil: +49 (0) 160 473 72 88
rohr@detectomat.com

United Kingdom, Ireland

Southern Europe

Asia, Oceania, America,


South-America, Africa, Near East

Davic B. Leigh

Daniel Fernandes

Jens Rittmeyer

Leigh Anderson Associates Ltd.


Tel.: +44 1579 321 750
Fax: +44 1579 321750
Mobil: +44 7770 404354
DBL@leighandersonassociates.com

detectomat office Portugal


Tel.: + 351 2180231-31
Mobil: +351 93 651 76 63
fernandesr@detectomat.com

Tel.: +49 (0) 4102 2114 598


Fax: +49 (0) 4102 2114 670
Mobil: +49 (0) 175 266 33 28
rittmeyerr@detectomat.com

4. Fire alarm systems

Fire alarm system detect 3000


Complexity in perfection
The fire alarm system detect 3000 and the corresponding detectors and modules of
the loop3000 -protocol are established as a future oriented system in the domestic and
international markets. It can be autoaddressed or manually addressed and offers a wide
accessory portfolio to enable solutions in all applications.

System detect 3000 features:


Highest reliability and fastest detection of fires
Best resistance against disturbance values
Completely certified according to European and national standards
Easiest programming, operation and display
Easy installation and fault diagnostics
Suitable for different projects and applications
High variety in detector design
Certified according to EN 54 standards
The system detect 3000 flexible, robust and time-saving with easy operation

4. Fire alarm systems

Fire Alarm System detect 3000


Schematic representation

BaCnet
ModBus

Please find detailed technical information of all


components next to your corresponding contact
at www.detectomat.com

4.1 Fire control panel dc3400 SC and accessories


4.1 Product overview

detect control dc3400 SC


and accessory
With the new detect control dc3400 SC detectomat is presenting an additional innovative product for the detect
3000 series. As basic version of a new generation of fire control panels the detect control dc3400 SC enables a
connection of up to 126 loop3000-participants.
The common software tool for detect 3004plus and detect control dc3400 SC allows an easy programming and
operation of the fire control panel. All parameters and selectable options are executed analog.
Additional features for alarm control and more detailed text information is integrated to the detect control
dc3400 SC. The panel can be updated to the next generations by software.

detect control dc3400 SC features:



Integrated touch screen-operation unit for


easiest operation and clear display

Modern software control for highest reliability

Continuous update and easy service for all


devices without exchange


Operation and programming via common

software tool for detect 3004plus and

detect control dc3400 SC for highest system
functionality

EN 54 conform, easy and clear display of all


messages

Please find detailed technical information of all


components next to your corresponding contact at
www.detectomat.com

4.1 Fire control panel dc3400 SC and accessories


4.1 Product overview

Fire control panel dc3400

dc3400 SC

VdS approval G 208123

Art-No.: 32530

Microprocessor controlled compact fire control panel for use with the loop3000
fire detection system components approved according to EN 54-2 A1 2006 and
EN 54-4 A1 2003 and A2 2006

Technical data
Input voltage

Power supply

Emergency backup
Interfaces
Ambient temperature

Humidity
Protection class
Colour
Material
Dimensions (H x W x D)
Weight
Standards

System approval
CE-CPD-number

In-/output module

84 up to 264 V AC/120 bis 300 V DC/


47 up to 63 Hz
32 V DC/150 W/3,5 A
1 output 400 mA for external user
2 x 12 V/12 Ah
USB, RS 485
0 C up to 50 C
5 up to 95 % (non-condensing)
IP 30
Light grey RAL 7035
Sheet steel
300 mm x 400 mm x 135 mm
12 kg, without batteries
EN 54-2: 1997/A1: 2006
EN 54-4: 1997/A1: 2002/A2: 2006
S 208123
CE 0786-CPD-20770

Clear display and easy operation via 5,7 Touchscreen - Display, 320 x
240 pixel with backlight 18 LED indicators for status notifications
Integrated 1 loop - interface for the connection up to 126 loop devices
of the loop3000 series
Integrated USB-interface for the easy programming via DCT-software
RS 485-interface for external printer
Integreated primary switched power supply 150 W according to
EN 54-4 A2 2006
1 Loop 200 m up to 126 mA/3500 loop3000-elements
3 clean potential-free relay outputs for alarm and fault
2 freely programmable monitored inputs
1 monitored output 24 V/400 mA for alarm devices
Emergency backup via 2 batteries 12 V up to 12 Ah
Up to 142 programmable zones
Event memory up to 9999 events
Circuit mapping for IOs of the loop3000 progarmmable
Customer specific texts for zones or detectors with up to 40 characters
8 integrated languages (German, English, Dutch, Czech, Spanish,
Portugese, Italian, French)
Integrated alarm buffer and 2 detector/2 zone dependencies
Programmable reaction and inspection times
Software update via USB-interface
Programmable alarm modes

IOM 3322

VdS approval G 205029

Art-No.: 30075
Intelligent Input-/output module for the loop3000 with bidirectional isolator
according to EN 54-18 with two monitored inputs and one potentialfree relay
output

Technical data
Operation Voltage
15 to 30 V DC loop powered on

two-wire bus
Quiescent current
760 A
Alarm current
760 A; 5 mA if alarm-LED is active
Output
2 relays 1 change over contact

30 V DC/1A
Input
2 low active monitored
Weight
Approx. 190 g
Protection class
IP 54
Colour housing
Grey (similar to RAL 7035)
Material ABS
Dimensions (H x W x D)
93 mm x 93 mm x 55 mm
Standards
EN 54-17, EN 54-18
System approval
S 295054, S 208123 und S 210001
CE-CPD-number 0786-CPD-20459

Connecting module with two freely programmable input and two freely
programmable output
Programming of different switching variants of input and output also
with time control
Monitoring of the operating status via loop3000
Independent programming of input and output
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
Functions completely integrated via loop3000-protocol
Multicolour-LED for alarm- (red) and fault (yellow)
Aestethical robust wall mounted housing according with IP 54

Accessories:
Possibility for monitoring of the output with UBW 3311 (Art.No. 32073)
General remarks: Only compatible to the control panels of type

detect 3400

10

4.2 Fire control panel detect 3004plus and accessories


Product overview

Fire control panel


detect 3004plus and accessories
The modular fire alarm panel detect 3004plus is the basic version of a broad product portfolio of the system detect
3000. Up to 20 fire control panels can be configured in a network.
Up to 4 loops with up to 126 devices can be connected per panel which enables system solutions with up to
10.080 addressable loop3000 -components. A modern configuration and diagnostic tool ensures highest program
stabilities and easy operation.
All parameters and selectable options are described with help functions to ensure an easy operation of the detect
3004plus.

detect 3004plus features:


Up to 20 fire control panels in one network.
Redundant version of the fire alarm system for highest reliability
Optional modules allowing extinguishing control according to EN 12094
Operation and programming via software tool dpt and diagnostic tool I-Check
EN 54 conform, easy and clear display of all messages
Please find detailed technical information of all components next to your corresponding contact
at www.detectomat.com

11

4.2 Fire control panel detect 3004plus and accessories


Product overview

Fire control panel detect 3004plus, language kit english


detect 3004plus M GB
Art-No.: 32551
Microprocessor controlled modular fire control panel for the use with the
loop3000 fire detection system components
Approved according to EN 54-2 A1 2006, EN 54-4 A1 2002, A2 2006 and VdS for
the use according to VdE 0833
Large LCD, 160 x 80 points with backlight
Integrated interface of foreign extinguishing systems using standard
interface delete according to VdS
Monitoring of the power supply and the battery according to
EN 54-4 2002 A1/A2 2006 on monitoring card MC 3004
Complies with EN 61000-6-3 class B for broadcast and is therefore
suitable for use in sensitive areas
Easy menu structure according to EN 54-2 A1 2006
Integrated one-man-audit mode with clear logging and auditing counter
Integrated display and control panel according to EN 54-2 A1 2006
2 slots for 2 loop - interfaces for the connection of up to 4 loops with a
maximum of 126 loop3000 devices per loop and a maximum
loop length of up to 3500 m
Option for 2 conventional interface cards for controlling up to
16 conventional zones
Extinguishing interface for controlling extinguishing and
gas suppression systems in accordance to EN 12094
Connections for a fire brigade interface for controlling the
panels outputs, key deposit and transmission units
Integrated interface connection for up to 63 additional
network components
Integrated RS 232-interface for the DPT programming software and
the connection of printers and other peripheral equipment
Integrated power supply 72 W according to EN 54 with 1 output for
external devices rated at 24V DC/800mA
1 external output 24 V/400 mA monitored for sounding/signalling
devices
3 potential free relais for fire and fault
3 inputs for collective signals
Emergency power supply via 2 batteries 12 V up to 26 Ah
Integrated ground fault monitoring
Segmented front door allowing the quick assembly of LED indicator
modules and printers
Option for customised front logos
Possibility for complete system redundancy with the CPU and
loop interfaces
Up to 128 programmable detector zones
Additional up to 42 T-branches per loop possible
Event log memory of up to 500 messages
Programming of control logics and time dependent functions for the
components of series loop3000
Customized customer texts allowing up to a maximum of 20 characters
Integrated alarm buffer and 2 detector/zone dependencies
Time controlled changeovers of sensitivity levels of
loop3000 detectors by day/night modes
Software controlled disablements for zones and individual detectors via
external inputs
Ability to change and edit inspection and reaction times along with all
delays
Programming options for different alarm modes
Different access levels with password protection
Visual diagnostics and remote-control operations via the visualization
software Visual detect
Commissioning and service tool for analyzing and fault finding
functions with I-check software
Inclusive English language kit for control and programming

12

4.2 Fire control panel detect 3004plus and accessories


Product overview

Technical data
Supply voltage
230 V AC (-15 % / +10 %)
Power supply
24 V DC/72 W/3,5 A

1 output 24 V DC/800 mA for

external devices
Emergency supply
2 x 12 V/26 Ah
Interfaces RS-232

Bitbus (RS 485 based),

Fire brigade interface
Display
LC-display 160 x 80 points Backlight
Outputs
1 x 24 V/400 mA monitored for

sounding/signalling devices

up to 4 loop 140 mA / 3500 m for

up to 126 Loop3000 elements

each 3 relais outputs 250 V/5 A

for alarm and fault

8 open collector outputs

30 V DC/90 mA
Inputs
3 inputs for collective signal
Ambient temperature
-5 C up to +40 C
Protection class
IP 30
Colour
Light grey, RAL 7035
Material
Sheet steel
Dimensions (H x W x D)
490 mm x 420 mm x 210 mm

deep housing
Weight
12,0 kg without batteries
Standards
EN 54-2: 1997 A1:2006

EN 54-4: 1997 A1:2002 A2:2006
VdS approval
G 203068
System approval
S 295054 und S 210001
CE-CPD-number 0786-CPD-20817
Further approvals
EN 12094 for 1 area

extinguishing systems

International approvals on

request
General remarks
Scope of delivery without

loop cards, network interfaces

and batteries

Utilization of integrated standard

extinguishing interface requires

1 optional LED indicator module

in the front to ensure the

indication according to EN 54-2

Fire control panel detect 3004plus, language kit english


VdS approval G 203068

Technical data
Dimensions (H x W x D) 490 mm x 420 mm x 150 mm

shallow housing

detect 3004plus S GB
Art-No.: 32553
Microprocessor controlled modular fire control panel for the use with the
loop3000 fire detection system components
Approved according to EN 54-2 A1 2006, EN 54-4 A1 2002, A2 2006 and VdS for
the use according to VdE 0833
Properties and technical data like Art.No. 32551

13

4.2 Fire control panel detect 3004plus and accessories


Product overview

1 Loop - interface, active, 140 mA for detect 3004



VdS approval with detect 3004plus

DLI 3240PS X1 1L
Art-No.: 32737
Microprocessor controlled loop interface for the uninterruptible and
short-circuit-proof use with the loop3000 fire detection system components.
For the connection of 126 fire detection system components on one loop
or 2 spurs














Technical data
Supply voltage
Emergency supply
Interfaces
Outputs
Dimensions (H x W x D)
Standards
System approval

20 to 32 V DC via detect 3004 supply


Via detect 3004 supply
1 x RS-232
Alternative 2 stitches
140 mm x 140 mm x 30 mm
EN 54-2 and EN 54-17
S 295054 and S 210001

Connection of loop3000 components in loop structure or spur-structure


2-wire-system loop with up to 3.500 m loop length,
(using wire lead JY(St)Y 2x2x0,8mm)
Easy and flexible installation and initialization via automatic and
manual addressing
Integrated RS-232 interface for an easy analysis of the loop components,
the preadjustment of functions and commissioning of loop3000
8 integrated freely programmable open-collector-alarm outputs
2 integrated open-collector-alarm outputs for the programming of
collecting functions
Supply via fire control panel detect 3004
Integrated short circuit isolaters on all loop outputs
Up to 42 T-branches per loop possible
Commissioning and service tool for analyzing and fault finding
functions with I-Check software

2 Loop - Interface, active, 2 x 140 mA for detect 3004plus



VdS approval with detect 3004plus

DLI 3240PS X1
Art-No.: 32738
Microprocessor controlled loop interface for the uninterruptible and short-circuitproof use with the loop3000 fire detection system components
For the connection of 2 x 126 fire detection system components on two loops or
4 spurs
Properties and technical data like Art.No. 32737

2 Loop - Interface, active, 2 x 140 mA, redundant



VdS approval with detect 3004plus

DLI 3240PS X1 - R
Art-No.: 32739
Microprocessor controlled loop interface for the uninterruptible and short-circuitproof use with the loop3000 fire detection system components
For the connection of 2 x 126 fire detection system components on two loops or
4 spurs
With a second processor for increased reliability in the loop (redundancy)
Properties and technical data like Art.No. 32737

Conventional interface for 8 fire zones



VdS approval with detect 3004plus

CLI X1
Art-No.: 30210
Microprocessor controlled conventional interface for the uninterruptible
and short-circuit-proof use with conventional detectors of the series CT 3000





Technical data
Supply Voltage

Emergency supply
Dimensions (H x W x D)
Standards
System approval

Connection of up to 25 automatic conventional detectors of the series


CT 3000 (10 manual call points) per detector zone
8 integrated freely programmable open-collector-alarm outputs
2 integrated open-collector-alarm outputs for the programming of
collecting functions
Supply via fire control panel detect 3004

20 to 32 V DC via
detect 3004 supply
Via detect 3004 supply
140 mm x 140 mm x 30 mm
EN 54-2, EN 54-17
S 295054 and S 210001

14

4.2 Fire control panel detect 3004plus and accessories


Product overview

LED indicator module for 8 zones



VdS approval with detect 3004plus

ZM 8
Art-No.: 30088
LED indicator module for the status indication of 8 detector zones with yellow
LEDs for fault and red LEDs for alarm for the mounting into the front door of the
fire control panel detect 3004

Technical data
Supply Voltage

Emergency supply
Dimensions (H x W x D)
Standards
System approval

20 to 32 V DC via
detect 3004 supply
Via detect 3004plus
80 mm x 43 mm x 12 mm
EN 54-2, EN 54-17
S 295054 and S 210001

Suitable for all fire control panels of the series detect 3004
8 red LEDs for the indication of alarms of each detector zone
8 yellow LEDs for the indication of faults of each detector zone
Direct connection to the CPU via a 10 pole ribbon cable (included
in delivery)
Possibilty for the labelling of each detector zone in the front of the
panel, by the integration in the front plate MP 3004 (not included in the
basic version)

General remarks:


Extinguishing Display board for detect 3004plus

Up to 6 LED indicator modules can be connected in the


front of the panel 2 modules can be connected directly
to the CPU. For the modules 3-6 an adapter board will
be necessary (Art.-No. 30386)

EXT 3004plus

Art-No.: 32559

Extension Module for LED indicator 3-6

ADB 48

Art-No.: 30386
For detect 3004 and detect 3004plus

Extinguishing display board TIB


Art-No.: 30090
For the fire control panel detect 3004plus

Transmission interface kit for detect 3004plus

UEI 3004plus - Kit

Art-No.: 32778

Mounting Plate

MP 3004

Art-No.: 31946
Single display and printer for detect 3004

Mounting plate

CPMP 3004plus

Art-No.: 32560
For display extinguishing interface and printer for 3004plus

Assembly frame 19 -12 HE for detect 3004plus

RMK 19

Art-No.: 30161

Extinguishing control card,


ETB X1
Art-No.: 30111
1 extinguishing area for detect 3004 and detect 3004plus

Redundance-Calculator

CPU X1-R

Art-No.: 30113

Additional casing, deep for detect 3004plus

UZG 1

Art-No.: 31318

15

4.2 Fire control panel detect 3004plus and accessories


Product overview

Fire protection housing F30, detect 3004plus, S, M

BSG 3004

Art-No.: 32441
Fire protection housing F30 as empty housing for the installatin of fire control
panels detect 3004plus S or M size

Technical data
Protection class
Colour
Inside dimensions
Outside dimensions
Dimensions
Cable refrigerated
(H x W x D)
High units
Width units
Place units
Weight
Weight EABK-2
VdS approval
Further approvals

IP 42
RAL 7035 (light grey)
(H x W x D) 750 mm x 500 mm x 340 mm
(H x W x D) 914 mm x 664 mm x 496 mm
500 mm x 620 mm x 195 mm
5 HE
2 BE
120 PE
116 kg
25 kg
4102 Part 2
Z-86.1-9, Z-86.1-7

Fire resistance and funtional integrity of more than 30 minutes


accoding to F30, tested according to DIN 4102 part 11 and 12
Smoke proof design with surface coating A2 - non combustible,
protection class II
With cable cooling part EABK-2 and electromagnetic lock of the
ventilation opening EBEL-EM
Housing for the on wall mounting with door stop left side
Removable door with locking option via turning lever
Angle of aperture of the door approx. 180
Cable sealing for bundly entry (top, down, both sides)
Including mounting strap for wall mounting
Locking via driving plate with 2 point interlocking
Tridimensional adjustable entry system for all standard device
mounting types
Integrated air cooling system via the backside and ventilation part with
locking activation and automatic triggering in case of fire
Locking activation at rise of temperature and electromagnetic activation
of the breather hole via smoke detectors
Highest mechanical strenght and chemical resistance
Integrated adjustable mounting system for the installation of the
fire control panel detect 3004plus

Fire protection housing F30, Type 2 for detect 3004

BSG 3004-1

Art-No.: 32724

Output card sounder, 4 outputs, monitored

SC 4

Art-No.: 32066
Output card for a monitored connection of up to 4 additional shortcircuitproof signal lines to the fire control panels of series detect 3004/3016

Technical data
Input voltage
21 up to 37 V DC
Material ABS
Dimensions (H x W x D)
125 mm x 130 mm x 70 mm

Possibility for 4 additional monitored and short-circuit-proof outputs


with max. 580 mA line current each
Connection of high and low resistant signalling devices via integrated
pole switch
Outputs can be activated to be dependend on the buttom
ext. Warning on/off of the fire control panel
4 inputs for the control of signal lines
Adjustment possibility for individual or collective control of all signal
lines via jumper
24 V supply via supply unit of the fire control panel
Module-housing for the easy mounting onto a DIN rail
12 LEDs for indication of operation and status
Cascading option of multiple modules of the same type

16

4.2 Fire control panel detect 3004plus and accessories


Product overview

Relay board, 8 change over contacts for detect 3004/3016

RB 8

VdS approval G 203068

Art-No.: 30077

Control board for the connection of up to 8 additional external change over


contacts for the fire control panels detect 3004/3016

Technical data
Input voltage
21 up to 28 V DC
Material ABS
Dimensions (H x W x D)
125 mm x 110 mm x 60 mm

Possibility for 8 additional change over contacts for the control of


external circuits of up to 250 V/5A
8 low-active inputs for the parallel switch of the outputs of the control
board
1 input for the release or the switch off of the functions of the control
board (e.g. at FCP - door open)
Power supply 24 V via power supply unit of the fire control panel
Module-housing for the easy mounting onto a DIN raile
8 LEDs to indicate the status of the outputs

Alarm control module, 32 OC-outputs AM


VdS approval G 203036

Art-No.: 30115
Microprocessor controlled extension module for 32 additional programmable
alarm outputs (OC-outputs) for the extension of the output matrix of the fire
control panels detect 3004/3016

Technical data
Input voltage
Outputs
Dimensions (H x W x D)

21 up to 28 V DC
32 alarm zones
140 mm x 140 mm x 25 mm

Extension for 32 programmable alarm output areas


Activation via internal IC-bus or via RS-232-Interface of the fire control
panel
Remote mounting by connectors (via RS-232)
Power supply 24 V via power supply unit of the fire control panel
Easy mounting via 32 pole pin contact bar in the connection board of
the detect 3016, via ribbon cable of the detect 3004 or the adapter
plate (Art.-No. 30116)

Connection board for alarm module AM 30115

AM AP

VdS approval G 203068

Art-No.: 30116

Adapter module for the external use or remote mounting of the alarm module AM
outside of the fire control panels detect 3004/3016
Module housing for easy mounting on DIN-rail
Terminal block for easy external circuits
Remote mounting by connectors possible

Technical data
Material ABS
Dimensions (H x W x D)
88 mm x 175 mm x 70 mm

Mount in printer for detect 3004plus

PIP 3004plus

Art-No.: 32558
Mounting Plate (Art.-Nr. 32560) is required

Thermo-paper for PIP 2 and PIP 3004plus

EP 5

VdS approval G 203068

Art-No.: 30107

Packing unit 5 rolls

17

4.2 Fire control panel detect 3004plus and accessories


Product overview

Primary 1,5 A synchronized mains adapter

BF 360-24

VdS approval G 208156

Art-No.: 32805

Universal primary synchronized mains adapter for the use as an emergency


power supply unit for the detect 3000 range
Approved according to EN 54-4 A1 2002, A2 2006 and VdS for the use according
to VdE 0833

Technical data
Input voltage
230 V AC/50 Hz
Output voltage
24 V
Output current
1,5 A according to operation mode
Battery capacity
Max. 2 x 12 V/3,4 Ah
Protection class
IP 30
Colour Grey
Material ABS
Dimensions (H x W x D)
380 mm x 235 mm x 96 mm
Weight
1,5 kg withouit batteries
CE-CPD-number 0786-CPD-20672

Primary synchronized switching power supply with electronic overload


functions
Integrated low voltage discharge protection
Controlled output voltage 24 V
Intelligent battery-management

Primary 2 A synchronized mains adapter 2402STE


VdS approval G 209142

Art-No.: 32579
Universal primary synchronized mains adapter for the use as an emergency
power supply unit for the detect 3000 range
Approved according to EN 54-4 A1 2002, A2 2006 and VdS for the
use according to VdE 0833

Technical data
Output current
2,0 A
Battery capacity
Max. 2 x 17 Ah
Protection class
IP 20
Colour White
Material
Sheet steel
Dimensions (H x W x D)
420 mm x 400 mm x 80 mm
Weight
9 kg
CE-CPD-number 0786-CPD-20787

Primary synchronized switching power supply with electronic


overload functions
Integrated low voltage discharge protection
Controlled output voltage 27,6 V
Flexible input voltage range 110 to 230 V
LED - fault display and potential free fault outputs
Intelligent battery-management

Pimary 5 A synchronized mains adapter 2405STE


VdS approval G 209142

Art-No.: 32580
Universal primary synchronized mains adapter for the use as an emergency
power supply unit for the detect 3000 range
Approved according to EN 54-4 A1 2002, A2 2006 and VdS for the
use according to VdE 0833

Technical data
Output current
5,0 A
Battery capacity
Up to 2 x 17 Ah in the housing

Up to 2 x 38 Ah with separate

housing
Protection class
IP 20
Colour White
Material
Sheet steel
Dimensions (H x W x D)
420 mm x 400 mm x 80 mm
Weight
9 kg
CE-CPD-number 0786-CPD-20787

Primary synchronized switching power supply with electronic


overload functions
Integrated low voltage discharge protection
Controlled output voltage 27,6 V
Flexible input voltage range 110 to 230 V
LED - fault display and potential free fault outputs
Intelligent battery-management

18

4.2 Fire control panel detect 3004plus and accessories


Product overview

Accumulator additional housing for 2405STE

BATT-BOX-3802 V

VdS approval G 209142

Art-No.: 32659

Dimensions (H x W x D) 420 mm x 420 mm x 180 mm

Accumulator 12 V/3,4 Ah LC-R123R4PG


VdS approval G 191053

Art-No.: 32809
Dimensions (H x W x D) 66 mm x 134 mm x 67 mm

Accumulator 12 V/7,2 Ah

WP 7.2-12

VdS approval G 103061

Art-No.: 40056

Dimensions (H x W x D) 94 mm x 151 mm x 65 mm

Accumulator 12 V/12 Ah

WP 12-12

VdS approval G 103063

Art-No.: 30155

Dimensions (H x W x D) 100 mm x 151 mm x 99 mm

Accumulator 12 V/18 Ah

WP 18-12

VdS approval G 103064

Art-No.: 30156
Dimensions (H x W x D) 167 mm x 181 mm x 76 mm

Accumulator 12 V/26 Ah

WP 26-12

VdS approval G 103065

Art-No.: 40001
Dimensions (H x W x D) 125 mm x 166 mm x 175 mm

Accumulator 12 V/38 Ah

NP 38 - 12

VdS approval G 103061

Art-No.: 32544
Dimensions (H x W x D) 99 mm x 150 mm x 65 mm

Accumulator 12 V/45 Ah

WP 45-12

VdS approval G 102002

Art-No.: 30151

Dimensions (H x W x D) 171 mm x 198 mm x 166 mm

Accumulator 12 V/65 Ah

WP 65-12

VdS approval G 105088

Art-No.: 30461

Dimensions (H x W x D) 174 mm x 350 mm x 166 mm

Conductor XT-base

BXT BAS

VdS approval G 608001

Art-No.: 32495

Dimensions (H x W x D) 90 mm x 12 mm x 44 mm

Combined conductor module 48 V for loop wires

BXT ML4 BE 48

VdS approval G 608001

Art-No.: 32496

Dimensions (H x W x D) 45 mm x 12 mm x 51 mm

Combined conductor module 24 V for signal lines

BXT ML4 BE C24

VdS approval G 608001

Art-No.: 32497

Dimensions (H x W x D) 45 mm x 12 mm x 51 mm

Combined conductor module 5 V for data lines

BXT ML4 BE HF 5

VdS approval G 608001

Art-No.: 32498

Dimensions (H x W x D) 45 mm x 12 mm x 51 mm

19

4.2 Fire control panel detect 3004plus and accessories


Product overview

Remote Display- and Control Panel, master, small housing

ABF Master XS GB

VdS approval G 203068

Art-No.: 32426

Microprocessor controlled modular remote display control panel for the control of
a network of fire control panels of the series detect 3004/3016

Technical data
Operation voltage
24 V DC
Interfaces
RS-232 Integrated Bitbus-Interface
Display
LC-Display 160 x 80 points

Backlight

20 LED-displays for status signal
Outputs
1 x 24 V/400 mA monitored for


sounding/signalling devices

3 Relays outputs 250 V/5A for

alarm and fault

8 open collector outputs

30 V DC/90 mA
Ambient temperature
-5 C up to +40C
Protection class
IP 30
Colour
Light grey RAL 7035
Material
Sheet steel
Dimensions (H x W x D)
262 mm x 420 mm x 83 mm
Weight
6,0 kg
Standards
EN 54-2: 1997 A1: 2006

EN 54-4: 1997 A1: 2002 A2: 2006
System approval
S 210001
CE-CPD-number 0786-CPD-20817

4 alphanumeric lines LC-display with backlight


Integrated display and control panel according to EN 54-2 A1 2006
Integrated module for the connection to a network of fire control panels
of the series detect 3004/3016
Up to 20 fire control panels can be configured in a network
Integrated RS 232-Interface for an easy programming with the
dpt-software and the connection of printers and other peripheral
equipment
External voltage supply 24 V required
3 potential free relays for fire and fault
3 inputs for collective signals
Integrated ground fault monitoring
Option for customised front logos
Event log memory of up to 1000 messages
Programming option for offset assignment for the control of all
network participants
Different access levels with password protection
Visual diagnostics and remote-control operations via the visualization
software Visual detect
Including english language kit for control and programming

Remote display control panel, slave, small housing ABF Slave XS GB


Art-No.: 32427

Technical data
Outputs






1x 24 V/400 mA monitored for


sounding/signalling devices
Up to 4 loops 140 mA/3500 for
up to 126 loop3000-elements
3 relays outputs 250 V/5A for
alarm and fault
8 open collector outputs
30 V DC/90 mA

Microprocessor controlled modular remote display control panel for the control of
a network of fire control panels of the series detect 3004/3016
Properties and technical data like Art.No. 32386

20

4.2 Fire control panel detect 3004plus and accessories


Product overview

LCD-Fire Control Tableau, GB

LCD Tableau GB

Art-No.: 31623
Microprocessor contolled modular Display for the display of messages of the fire
control panels series detect 3004/3016 and a network

Technical data
Operation voltage
24 V DC
Interfaces
RS-232 Integrated Bitbus-Interface
Display
4-line alphanumeric

display LC display

Backlighted
Protection class
IP 30
Colour
Light grey RAL 7035
Material ABS
Dimensions (H x W x D)
240 mm x 295 mm x 43 mm
Weight
1,8 kg

4-lines alphanumeric LC display with 10 mm character size with


backlight
Integrated module for the connection to a network of fire control panels
of series detect 3004/3016
Integrated scroll- and acoustics-function with control via control keys
Programming and data copying via fire control panel detect 3004/3016
Requires external voltage supply of 24 V
Including English language kit for control and programming
Aesthetically pleasing stainless steel housing with lockable front door

Network-Interface, Bitbus BBI


Art-No.: 30087
Plug in module for a network integration of the fire control panels
detect 3004/3016 in a network of up to 64 participants

Technical data

Plug in board for direct mounting into the fire control panels
detect 3004/3016
Suitable for a direct connection of 2 network participants with a
distance of up to 1.200 m
For up to 64 network participants in one network
Voltage supply via the fire control panel

Operation voltage
24 V DC
Current consumption
Approx. 50 mA
Interfaces Bitbus-Interface
Protection class
IP 20
Dimensions (H x W x D)
49 mm x 59 mm x 20 mm

21

4.2 Fire control panel detect 3004plus and accessories


Product overview

Network-PC-Interface, PCI-BITBUS

IPC - BIT900-PCI

Art-No.: 32257
PC-plug in card for the integration of a PC as a Bitbus-participant in the network
of fire control panels of the series detect 3004plus

Technical data
Operation voltage
Interfaces
Protection class
Dimensions (H x W x D)

5 V DC via PC
2 x RS 485 9 pole Sub D/F and M
IP 20
190 mm x 128 mm x 12 mm

Plug in card for the direct mounting into the PC


Enables the Bitbus-operation with unlimited message length with
baud rates 62,5 kBit/s and 375 kBit/s
Operated as a slave participant in the Bitbus-network
Isolated RS-485-Interface with SN75LBC176-drivers and
substantial protection circuitry for aggressive industrial ambient conditions
End of line resistors (bus termination) switchable by DIP-switch
PC-Interface can be operated together with repeaters in the network
Factory provided pre-adjusted transmission speed of 62,5 kBit/s
Required drivers are provided with the visual detect setup programme
Front plate with LED for sender activity (yellow) and user-LED (green),
flashing with 1 Hz at standard software

Network-PC-Interface, USB-BITBUS

USB - BIT

Art-No.: 32258
Small and flexible PC-USB-module for the integration of a PC as a Bitbusparticipant into the network of fire control panels of the series detect 3004plus

Technical data
Operation voltage
Interfaces
Protection class
Dimensions (H x W x D)
General remarks


5 V DC via USB Interface of the PC


RS 485 9 pole Sub D/F USB-Port
IP 20
115 mm x 57 mm x 20 mm
Without integrated repeater for
the distance extension
The topology of the network has
to be considered at comissioning

Coupling and supply via USB port of the PC


Enables the Bitbus-operation with unlimited message length with
baud rates 62,5 kBit/s and 375 kBit/s
ARM-based Design with 32-Bit RISC processor and integrated SDLC
Isolated RS-485-Interface with substantial protection circuitry for
aggressive industrial ambient conditions
Switchable end of line resistors (bus termination)
Factory provided pre-adjusted transmission speed of 62,5 kBit/s
Required drivers are provided with the visual detect setup programme
With LED for sender activity (yellow) and user-LED (green), flashing
with 1 Hz at standard software

Network-PC-Interface, Ethernet-BITBUS

ETH - BIT R

Art-No.: 32259
PC-Ethernet-module for the integration of a PC as a Bitbus-participant in the
network of fire control panels of the series detect 3004plus
Comes with Din rail housing for an easy mounting on a DIN rail into
the fire control panel

Technical data
Operation voltage

Current consumption
Interfaces


Protection class
Dimensions (H x W x D)
General remarks



24 V DC via power supply of the


fire control panel
50 mA
RS 485 9 pole Sub D/M
Ethernet 10/100 Mbit/s via Cat5
Port
IP 20
140 mm x 118 mm x 45 mm
Without integrated repeater for
the distance extension
The topology of the network has
to be considered at comissioning

External 24 V supply via the power supply of the fire control panel
Enables the Bitbus-operation with unlimited message length with
baud rates 62,5 kBit/s and 375 kBit/s
10 and 100 MBit Ethernet via Cat5 LSA-block
32-Bit ARM7 with 2 MByte Flash and 512 kByte supported RAM
Isolated RS-485-Interface with substantial protection circuitry for
aggressive industrial ambient conditions
Bitbus end of line with defined potential
Factory provided pre-adjusted transmission speed of 62,5 kBit/s
Required drivers are provided with the visual detect setup programme
With LED for sender activity (yellow) and user-LED (green), flashing
with 1 Hz at standard software

22

4.2 Fire control panel detect 3004plus and accessories


Product overview

Network-PC-Interface, Ethernet-BITBUS IP 65

ETH - BIT

Art-No.: 32260
PC-Ethernet-module for the integration of a PC as a Bitbus-participant in the
network of fire control panels of the series detect 3004plus
In IP 65-housing for the assembly in aggressive ambient conditions

Technical data
Operation voltage
Current consumption
Interfaces


Protection class
Dimensions (H x W x D)
General remarks


24 V DC
50 mA
RS 485 Ethernet 10/100 Mbit/s
via Cat5 Port
RS-232 via cage clamp terminals
IP 20
118 mm x 140 mm x 45 mm
Without integrated repeater for
the distance extension
The topology of the network has
to be considered at comissioning

External 24 V supply via the power supply of the fire control panel
Enables the Bitbus-operation with unlimited message length with
baud rates 62,5 kBit/s and 375 kBit/s
10 and 100 MBit Ethernet via Cat5 LSA-Block
32-Bit ARM7 with 2 MByte Flash and 512 kByte supported RAM
Isolated RS-485-Interface with substantial protection circuitry for
aggressive industrial ambient conditions
Bitbus end of line with defined potential
Factory provided pre-adjusted transmission speed of 62,5kBit/s
Required drivers are provided with the visual detect setup programme
With LED for sender activity (yellow) and user-LED (green), flashing
with 1 Hz at standard software

Network-Bitbus-Repeater

BIT RPT

Art-No.: 32269
Bidirectional Repeater - Module for the extension of the cable length between fire
control panels of the series detect 3004/3016 in the Bitbus network. Coming in a
protected aluminium housing for wall mounting

Technical data
Operation voltage
12 up to 30 V DC
Current consumption
100 mA
Interfaces
RS 485 Master via Sub D 9 pole F and M

RS 485 Slave via Sub D 9 pole M
Protection class
IP 30
Dimensions (H x W x D)
64 mm x 151 mm x 48 mm

External 24 V supply via power supply of the fire control panel


Enables Bitbus use of up to 1200 m distance between two nodes at a
standard baud rate of 62,5 kBit/s
Integrated DC - inverter for the isolation of the input voltage
Integrated load resistance for the slave function
32-Bit ARM7 with 2 MByte Flash and 512 kByte supported RAM
Isolated RS-485-interface with substantial protective circuit for
severe industrial conditions
Bitbus cable end with predefined potential
With LED for the transmission status (yellow) and for the operating
status LED (green)

General remarks:


Bitbus-CPU, Network Output control board

Connector for current supply included in the scope of


delivery. The topology of the network has to be considered
at comissioning. The maximum length in the network is
13,2 km at baud rate of 62,5 kBIT/s (10 repeater)

AM AP

Art-No.: 30119
Microprocessor controlled control board for the direct control of outputs in a
network of fire control panels of the series detect 3004/3016 with up to 64
participants

Technical data
Operation voltage
21 up to 28 V DC
Current consumption
Approx. 140 mA
Interfaces
Bitbus - Interface RS-232
Protection class
IP 20
Material ABS
Dimensions (H x W x D)
125 mm x 133 mm x 58 mm
General remarks
Ribbon cable is included in the

delivery of the output modules

Connection diagram of the

control board is included at the

output modules

Control module for the direct control of relay or OC-output cards in the
network without the use of fire control panels detect 3004/3016
Easy connection of outputs cards via ribbon cable
Option for up to 8 output cards per output control board
Art.-No. 30120 and 30122
Up to 61 output control boards in one network
Direct addressing in the network via fixed address
External voltage supply 24 V DC
Programming with special software and connection of a modem
Art.-No. 30136
Overall network programming of the outputs with mapping of
corresponding subpanels
Integrated push button for manual reset-function
Red and green LED for the status display
Modulehousing for the easy mounting onto a DIN rail

23

4.2 Fire control panel detect 3004plus and accessories


Product overview

Network-Output card, 32 Open collector, Bitbus

BB 32 OC

Art-No.: 30120
32 Open Collector output card for the connection to the output control board for
the direct control of outputs in a network of fire control panels of series detect
3004/3016 with up to 64 participants

Technical data
Operation voltage
Supply via output control board
Outputs
32 open collector 24 V DC/90 mA
Protection class
IP 20
Material ABS
Dimensions (H x W x D)
125 mm x 163 mm x 58 mm
General remarks
Ribbon cable included in delivery

Output control board

(Art.-No. 30120) required for the

connection to the network

32 Open Collector Output card in a network for the use without a


fire control panel detect 3004/3016
Easy connection of outputs cards via ribbon cable, included in the
scope of delivery
Up to 8 output cards can be used with one
output control board - mixed solutions possible
( Art.-No. 30120 and 30122)
Voltage supply via the output control board (ribbon cable)
Overall network programming of the outputs with mapping of
corresponding subpanels
Addressing for the recognition by the control module via DIP-switch
4 pole terminal block for the possibility of an output supply voltage of
5 or 8 V, e.g. for LED-displays
Module-housing for the easy mounting onto a DIN rail

Network-Output card, 16 relays, Bitbus

BB 16 REL

Art-No.: 30122
16 relays-output card for the connection to the output control board for the direct
control of outputs in a network of fire control panels of series detect 3004/3016
with up to 64 participants properties

Technical data
Operation voltage
Supply via output control board
Outputs
16 relays 1 change over contact

30 V DC/2 A
Protection class
IP 20
Material ABS
Dimensions (H x W x D)
125 mm x 163 mm x 58 mm
General remarks
Ribbon cable included in delivery

Output control board

(Art.-No. 30120) required for the

connection to the network

16 Relays output card in a network for the use without a


fire control panel detect 3004/3016
Easy connection of outputs cards via ribbon cable, included in the
scope of delivery
Up to 8 output cards can be used with one output control board,
mixed solutions possible ( Art.-No. 30120 and 30122)
Voltage supply via the output control board (ribbon cable)
Overall network programming of the outputs with mapping of
corresponding subpanels
Addressing for the recognition by the control module via DIP-switch
Modulehousing for the easy mounting onto a DIN rail

Network-LED-Control card, Bitbus

BB LED

Art-No.: 30128
Microprocessor controlled control card for the direct control of up to 196 LEDs in
a network of fire control panels of the series detect 3004/3016

Technical data
Operation voltage
21 up to 28 V DC
Interfaces
Bitbus-interface RS-232
Outputs
6 x cable connection for CP ZM 32

3 relays 30 V/2 A
Protection class
IP 20
Material ABS
Dimensions (H x W x D)
2 pieces

125 mm x 133 mm x 58 mm

Control module for the direct activation of LEDs in a network without


use of the fire control panel detect 3004/3016
Consists of 2 modules with same dimensions
Easy connection of up to 6 pieces of the 32 LED indicator module
ZM 32 (Art.-No. 30098) via ribbon cable
Up to 61 participants (Control cards) connectable in a network
Direct addressing in the network by a fixed address
External voltage supply of 24 V DC required
Cross-network programming of the outputs with mapping to the subpanel
Integrated push button for a manual reset function
Red and green LED for the display of the operation status
Module-housing for an easy mounting onto a DIN rail

Accessories: LED indicator module (Art.-No. 30098)

24

4.2 Fire control panel detect 3004plus and accessories


Product overview

Network-converter BITBUS-LWL

RS-485 LWL

Art-No.: 32479
Monitored converter module for the use of fibre optics cable run in the Bitbus
network of the fire control panels of the series detect 3004/3016

Technical data
Operation voltage
Current consumption
Outputs

Protection class
Dimensions (H x W x D)

18 up to 32 V DC
500 mA
Change-over contact via 3 pole
plug terminal (fault output)
IP 30
115 mm x 36 mm x 107 mm

Enables external redundant 24 V supply via 2. galvanically isolated


supply
Enables Bitbus-operation with fibre optics multimode cable
62,5/125 m or 50/125 m and ST - connectors
Robust industrial housing made of metall, suitable for the mounting on
a DIN rail
6 LEDs for operating state, sending and receiving on both sides, fault
Isolated RS485-Interface with substantial protection circuitry for
aggressive industrial ambient conditions
Enables Bitbus-operation with unlimited message length with
baudrates of 62,5 kBit/s and 375 kBit/s
Generation of a fault message via LED and an integrated alarm relays
in case of failure of the LWL-connection and disruption of the current
supply

Modular Bitbus - LWL - Splitter BBRS


Art-No.: 32675
Monitored converter module for the applicaton of fibre optics cables in the Bitbusnetwork of fire control panels of the series detect 3004plus

Technical data
Operation voltage
Current consumption
Interfaces


Protection class
Dimensions (H x W x D)

24 V DC + 10 %
100 mA
RS 485 via Sub D 9 pole F
LWL multimode 50/62,5 m via
SC duplex or ST - connector
IP 30
105 mm x 45 mm x 70 mm

Modular converter for the fail safe extension of Bitbus networks


Integrated repeater function for the application as signal amplifier in
the network
Enables external redundant 24 V supply via second galvanically isolated
supply
Cascading of up to 70 modules in a network is possible
Usable in switch or in splitter operation modus
Robust industrial housing, suitable for the mounting on a DIN rail
7 LEDs for operating state, operation per segment, fault per segment
Isolated RS-485-Interface with substantial protection circuitry for
aggressive industrial ambient conditions
Enables Bitbus-operation with unlimited message length with
baud rates of 62,5 kBit/s and 375 kBit/s
Generation of a fault message via LED and an integrated alarm relays
in case of failure of the LWL-connection and disruption of the current
supply

25

4.3 Software and tools for fire alarm systems


Product overview

I-Check 3000 Software

I-Check 3000

Art-No.: 30501
Software tool for the components of the loop3000 system for an easy
programming of the functions, analysation and diagnostics in case of service and
maintenance and for installation and commissioning.
Graphic user interface with display of the loop topology of the system detect 3000
for the documentation












Windows-based software tool with graphic display of the loop topology


Comprehensive diagnostic function for support at commissioning and
for the localization of installation faults of existing systems
Analysis of the operating data of all loop3000 components for
high service level of the system via graphic display of actual data like
pollution level, smoke concentration, temperature
Graphic display of the loop topology with actual addresses and serial
numbers of the components for the use for documentation and plans
Integrated system access function for the modification and change of
data also during operation (e.g. change of sensitivities, change of
mapping, change of module properties etc.)
Clearly arranged Windows user interface with print and export function
(Word, Excel)

Diagnostic and programming software tool

DPT 3000

Art-No.: 30136
Software tool for the easy programming of fire control panels of the series detect
3004/3016 and the network components of the system detect 3000plus





Windows based software tool with upload and download function for
the programming of the functions of the fire control panels of the series
detect 3004plus and the network components of the sytem detect 3000
via a personal computer
Import and conversion functions for different software versions
Integrated option for the remote diagnostics via modem

Integrated online-function
Option for customer specific texts



Integrated time function for the time programming of different functions


for the fire control panels detect 3004/3016
Clearly arranged Windows user interface with print and export function
(Word, Excel)

Diagnostic and programming tool Easy Check

EC 3000

Art-No.: 31482
Programming tool for the easy manual addressing and programming of the
loop3000 components
Battery powered Stand- Alone tool with up and downloadfunction for an
easy manual addressing and programming of the loop3000 components






Support for diagnostics and programming functions for all detectors


and modules
Easy assignment of customer specific detector data via integrated copy
and paste function
Four line LC Display with backlight and adjustable brightness for a
clear display of all values and data
16 buttom keypad for an easy use and clearly arranged input of data

Update option of the device software via integrated RS-232-interface


Scope of delivery: 1 Transportation suitcase

1 Easy Check

3 Batteries Type AA

1 Interface cable

1 Connection cable for modules and manual call points

1 Carrying strap

Automatic switching off function at no use for higher battery lifetime


Acoustic alert at low battery
The programming of the automatic detectors can be done directly via
the integrated detector base

26

4.3 Software and tools for fire alarm systems


Product overview

Loop-Tester

LT 3000

Art-No.: 31625
Programming tool for an easy automatic or manual (scanfunction)
addressing and programming of the components of the loop3000 via
a personal computer

Scope of delivery: 1 Suitcase



1 Loop - Tester

1 Voltage supply

1 Interface cable
General remarks: The programming has to be checked at comissioning of

the fire control panel

Stand-Alone device with up- and download function for an easy


automatic and manual (scanfunction) addressing and programming
of the components of the loop3000 via a personal computer without
the installation of a fire control panel
1 loop or 2 spurs suitable for connection for the complete test of the
detectors/modules installation or for the test of subareas
(e.g. difficult to access areas)
Including reset key for the reset of the loop tester to a defined basic
status
Complete support of all diagnostic and programming functions for all
detector and module data
Integrated RS-232-interface for bidirectional data communication
Easy programming and diagnostic and input of customer specific data
via diganostic software I-Check 3000
Unlimited use of all features of the diagnostic software I-Check
Including 230 V-voltage supply for the diagnostic tool

Bitbus programming modem BPT


Art-No.: 30139

PC - connection cable UPC


Art-No.: 32310

Protection dongle HL

Art-No.: 32208

USB converter, 1 m

USB 2.0

Art-No.: 32326

27

4.4 visual detect


Visualisation software and programming software for loop3000

visual detect
Software based visualisation and control of
systems of the series detect 3000
Customer specific analysis and administration of
data and events of the fire control system via visual
detect software
Computerised software for the event-orientated
administration and documentation of individual
panels or network systems
Extensive software tools enable clear and
easy operation, programming and installation and
implementation of the system
Increase of system functionality by control of multiple networks
Flexible parameters of the detect 3000 software and flexible interfaces of the
visual detect software can be used to integrate and connect the detect 3000 system to building
management systems (BMS)

Features of the visual detect Software:


Compact basic package
Extension options without additional efforts
Open interfaces
Clear operation interface
Please find detailed technical information of all
components next to your corresponding contact at
www.detectomat.com

28

4.4 visual detect


Visualisation software and programming software for loop3000

Visual detect Demonstration software

VD DV

Art-No.: 31911

Visual Detect Basis software

VD Basic 11

Art-No.: 30143
Software for the bidirectional visualisation and remote control of loop3000
networks and the fire control panels detect 3004/3016 as basic version for one
fire control panel and one PC

Windows based software licenced as basic version for one fire control
panel and one PC
Windows XP based network compatible software with Client/Server
architecture
Modular structure of graphical software for the realization of
different applications and extensions
Various user levels with extensive user and policy management and an
integrated simulation tool
Freely definable alarm management and procedure plans and
integrated tool for the automatic execution of procedure plans
Flexible with multilingual version and print-, export- and import
function
Highest system security via data encryption and seperate installation
and operation access levels
Extensive help functions integrated
Import of floor plans and programming data of the fire control panel via
standard files (dpt-files for programming data, dwg-files, wmf-files,
jpg-files, bmp-files etc. for floor plans)
Easy, clearly arranged specific programming via flexible surfaces
Extensive logging of all events and messages with option for specific
analysis and print of floor plans (also for fire brigade route cards)
Scope of delivery: CD with Installation software licence and USB-Dongle via
network-PC-interface, the personal computer can be installed at any place of the
network

Compact Paket visual detect

VD smart

Art-No.: 32268
Package with USB-interface and software for the bidirectional
visualization and remote control of one fire control panel of the series
detect 3004/3016
Compact version for one fire control panel and one PC, no extension
possible
Scope of delivery: CD with Installation software licence and USB-Dongle via
network-PC-interface, the personal computer can be installed at any place of the
network

Visual Detect User Extension

VD UE 1

Art-No.: 30144

Visual Detect Panel Extension

VD PE 1

Art-No.: 30145

Management - System - Interface visual detect

VD M I

Art-No.: 31654

Visual Detect Operation Extension

VD CE 1

Art-No.: 30146

Visual Detect Server Extension

VD MS 1

Art-No.: 32376

29

4.5 Addressable automatic detectors for loop3000 and accessories

Addressable automatic detectors


for loop3000 and accessories
To detect fires in the earliest stage was one of the main targets within the development of the detectors of the
loop3000 system. The elements are based on the EN 54 standards and meet the demands and requirements of the
international markets. Extensive analyzing methods and combinations of different sensor criteria and complex algorithms guarantee an easy operation and comprehensive maintenance and diagnostic features. The detectomatprotocol allows a detailed analysis and an adoption to the ambient conditions of the according application.
Redundant measurements ensure a high functionality and reliability.
The system parameters allow an easy operation and maintenance. Special integrated software features can
control all measurements and analyze accordingly to adjust the system performance to the application.

Features at a glance:
The addressable detectors are manufactured
according to EN 54-5, -7, -17* and -29.
High variety in design
Patented measurement methods
Verification and elimination of disturbance values
Controlled quality and retraceability
Fast and reliable fire detection
High operation reliability low operation costs
Automatic and manual addressable options
* only for types with description PL 3300

30

4.5 Addressable automatic detectors for loop3000 and accessories

Addressable automatic detectors for


loop3000 and accessories
Technical Data:
Exact pollution recognition by an additional independent
measuring chamber
All detectors with thermal function: Integrated temperature
measurement as rate of rise procedure and maximum value in
accordance to EN 54-5 A1 and A2
Detector sensitivities automatically calibrated and freely
programmable
Fault monitoring of the measurement chamber signal and
loop3000-electronics
Periodic sensor test
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option of types PL 3300
Alarm output for the triggering of LED indicators
Functions completely integrated via loop3000-protocol
Disable and enable modes with individually adjustable sensitivities
Storage of last maintenance date
Self learning modes for the ambient conditions
Display of the temperature environments of the fire detection system by a second
temperature measurement
Multicolour LED for alarm (red) and fault (yellow)
Delivery including protective cover for installation phase

Detectors

loop3000

Operating voltage

15 to 30 V DC loop powered

OC-outputs

Max. 10 mA for LED-indicator or piezo buzzer

Sensitivity

5 levels adjustable

Ambient temperature

-10C to +60C

Humidity

Max. 95 %

Air speed (opt. detector)

< 20 m/s

Protection class

IP 40

Colour housing

White (similar to RAL 9003)

Material*

ABS

Dimensions (H x )*

52 mm x 100 mm
*Design detectors different

Please find detailed technical information of all components next to your corresponding
contact at www.detectomat.com

31

4.5 Addressable automatic detectors for loop3000 and accessories

Multisensor optical-heat-intelligent, Fusion technology

PL 3300 OTi Fusion

VdS approval G 208095

Art-No.: 32149

Intelligent optical and thermal multi sensor detector for loop3000 with 2 optical
and 2 thermal sensors and a bidirectional isolator for earliest fire detection and
indication in all environments with difficult ambient conditions, according to EN
54-5, EN 54-7, EN 54-17 and EN 54-29

Technical data
Standards
EN 54-5, EN 54-7, EN 54-17, EN 54-29
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20580

Fusion - Technology for the detection of the smallest smoke particles


and fires in the early stage by using the wavelengths of the wide-band
white light spectrum
Integrated measurement-system and algorithm for condensation
recognition (Humitec)
Intelligent analysis and disruption mode for the elimination of false
alarms (e.g. cigarette smoke)
Highest reliability by intelligent combination of thermal and
optical sensor signals with via algorithms

Multisensor detector optical-heat - intelligent

PL 3300 OTi

VdS approval G 208096

Art-No.: 32150

Intelligent optical and thermal multi sensor detector for loop3000 with 2 optical
and 2 thermal sensors and a bidirectional Isolator for earliest fire detection and
indication in all environments with difficult ambient conditions, according to EN
54-5, EN 54-7, EN 54-17 and EN 54-29





Technical data

Integrated measurement-system and algorithm for condensation


recognition (Humitec)
Intelligent analysis and disruption mode for the elimination of false
alarms (e.g. cigarette smoke)
Highest reliability by intelligent combination of thermal and
optical sensor signals with via algorithms

Standards
EN 54-5, EN 54-7, EN 54-17, EN 54-29
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20580

Multisensor carbon monoxide gas & heat

PL 3300 COBT

VdS approval G 207005

Art-No.: 30079

Intelligent multi sensor detector for the loop3000 series featuring sensor
technology for carbon monoxide detection in combination with two thermal
detectors and an integrated Isolator for earliest detection and indication for all
environments with difficult ambient conditions, in accordance to EN 54-5 and
EN 54-17 For the earliest detection of smouldering fires of all kinds including
electrical. The PL 3300 COBT continuously monitors the temperature and the
CO-concentration

Technical data
Life time CO-Sensor
5 years
Standards
EN 54-5, EN 54-17
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20582
General remarks
The carbon monoxide detector requires a

calibration once a year to ensure the high

detection levels is maintained

Alarm evaluation with professional CO-sensor technology


Measurement of carbon monoxid with 2 alarm thresholds:
Prealarm: 15 ppm in 15 min, Alarm: 30 ppm in 60 min
Integrated acoustic indication for CO-pre alarm and CO-alarm
Highest reliability by intelligent combination of thermal and CO sensor
via algorithm

32

4.5 Addressable automatic detectors for loop3000 and accessories

Optical smoke detector, with isolator

PL 3300 O

VdS approval G 202002

Art-No.: 30011

Optical smoke detector for loop3000 with 2 optical and 1 thermal sensor for
earliest fire detection and indication and with bidirectional isolator according to
EN 54-7 and EN 54-17

Technical data
Dimensions (H x )
44 mm x 100 mm
Standards
EN 54-7, EN 54-17
VdS approval
G 202002
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20035

Optical smoke detector, without isolator

PL 3200 O

VdS approval G 202003

Art-No.: 30009

Optical smoke detector for loop3000 with 2 optical and 1 thermal sensor for
earliest fire detection and indication and with bidirectional isolator according to
EN 54-7 and EN 54-17

Technical data
Standards
EN 54-7, EN 54-17
VdS approval
G 202003
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20032

Heat detector with fixed and rate of rise temperature settings

PL 3300 T

VdS approval G 203037

Art-No.: 30010

Heat detector with fixed and rate of rise temperature settings for loop3000 with
1 thermal sensor for earliest fire detection and indication in all environments with
difficult ambient conditions and with bidirectional isolator according to
EN 54-5 and EN 54-17

Technical data
Standards
EN 54-7, EN 54-17
VdS approval
G 203037
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20044

33

4.5 Addressable automatic detectors for loop3000 and accessories

Optical smoke detector, with isolator, mesh design, white

PL 3301 O white

VdS approval G 205046

Art-No.: 30956

Optical smoke detector for loop3000 with 2 optical and 1 thermal sensor for
earliest fire detection and indication and with bidirectional isolator accord. to
EN 54-7 and EN-17

Technical data
Material
Metal mesh, ABS
Dimensions (H x )
44 mm x 100 mm
Standards
EN 54-7, EN 54-17
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20041

Optical smoke detector, with isolator, mesh design

PL 3301 O silver

VdS approval G 205046

Art-No.: 30488

Optical smoke detector, with isolator, mesh design

PL 3301 O black

VdS approval G 205046

Art-No.: 30525

Optical smoke detector, with isolator, round glass design


VdS approval G 204089

PL 3305 O white

Art-No.: 30567

Optical smoke detector for loop3000 with 2 optical und 1 thermal sensor for
earliest fire detection and indication and with bidirectional isolator according to
EN 54-7 and EN 54-17
Round glass design, white colour

Technical data
Material
Glass, ABS
Dimensions (H x )
47 mm x 110 mm
Standards
EN 54-7, EN 54-17
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20037

Optical smoke detector, with isolator, round glass design

PL 3305 O silver

VdS approval G 204089

Art-No.: 30568

Optical smoke detector, with isolator, square glass design


PL 3306 O white
Art-No.: 32289

Optical smoke detector for loop3000 with 2 optical and 1 thermal sensor for
earliest fire detection and indication and with bidirectional isolator according to
EN 54-7 and EN 54-17
Square glass design, white colour

Technical data
Material
Dimensions (H x W x D)

34

Glass, ABS
44 mm x 122 mm x 122 mm

4.5 Addressable automatic detectors for loop3000 and accessories

Optical smoke detector, with isolator, round flat design

PL 3307 O white

Art-No.: 32287
Optical smoke detector for loop3000 with 2 optical and 1 thermal sensor for
earliest fire detection and indication and with bidirectional isolator according to
EN 54-7 and EN 54-17
Round flat design, white colour

Technical data
Dimensions (H x )
Standards

Optical smoke detector, with isolator, round flat design

44 mm x 110 mm
EN 54-7, EN 54-17

PL 3307 O silver

Art-No.: 32288

Optical smoke detector, with isolator, with individual logo

PL 3308 O white

VdS approval G 208147

Art-No.: 32473

Optical smoke detector for loop3000 with 2 optical and 1 thermal sensor for earliest fire detection and indication and with bidirectional isolator according to EN
54-7 and EN 54-17
Round design, with individual logo, white colour

Technical data
Dimensions (H x )
55 mm x 113 mm
Standards
EN 54-7, EN 54-17
System approval
S 295054, S 208123 und S 210001
CE-CPD-number 0786-CPD-20575

Detector standard base with bridge, white

SDBB 3000

Art-No: 31959
Detector Base with integrated bridge suitable for all detectors of loop3000, white
Integrated wire link between minus contacts for ensurance of a closed
loop at removal of detector
Bridge opens automatically at installation of the detector in the base
Integrated connectors for LED indicator (Art.-No. 31193) or
piezo buzzer Art.-No. 32091
Space for additional connectors Type WAGO 243
Integrated connectors for the connection of one branch for the
loop extension (T-branch)
Mounting space for the piezo buzzer (Art.-No. 32091) and the
detector labelling clip Art.-No. 30479

Technical data
Colour housing
Material
Dimensions (H x )

White (similar to RAL 9003)


ABS
21 mm x 95 mm

Including transparent seal cover to protect the base against


contaminents

Detector standard base with bridge, silver

SDBB 3000 si

Art-No.: 32084

Detector standard base with bridge, black

SDBB 3000 sw

Art-No.: 32083

35

4.5 Addressable automatic detectors for loop3000 and accessories

Detector labelling clip, 30 pcs. MBC

Art-No.: 30479

Piezo buzzer SP

Art-No.: 32091

Design ring for ceiling mounting, silver

DR45 silver

Art-No.: 31684

Design ring for ceiling mounting, white

DR45 white

Art-No.: 32070

Rauchmelder
Base
with heater
optisch,

mit Isolator, Gitter - Design, silbern APS
PL 3301
b O silbern

Art-No.: 31875
30488

Rauchmelder
Protective
cage
optisch,
for detectors,
mit Isolator,
white SG
Gitter - Design, schwarz PL 3301 O schwarz

Art-No.: 32267
30525

Rauchmelder
Protective
cage,
optisch,
white,mit
for Isolator,
detectos,Glas
sirens
- Design
and beacons SK
rund, wei SK

Art-No.: 31317

Detector bracket 270 - 480 mm MKBD


Art-No.: 30187

Detector folding bracket 0 - 110 MKK


Art-No.: 30188

Detector distance console 80 mm MAK


Art-No.: 30189

Wall bracket 400 mm

WA 4

Art-No.: 30190

Wall bracket 200 mm

WA 2

Art-No.: 30191

36

4.5 Addressable automatic detectors for loop3000 and accessories

Duct housing Orbis

LKMG Orbis

Art-No.: 32894
Duct housing including air tubes and the use of Orbis detectors for a fire detection
outside of air ducts
Duct housing including air tubes for ducts with a maximum width of
560 mm
The duct housing may be used in air speeds of between 0,5 and 20 m/s
Integrated base for the application with an Orbis detector Art.-No.
32895

Technical data
Operation voltage
Via conventional line (12 V or 24 V)
Outputs
Potential free change-over

contact (30 V DC/1A)
Air duct size
From 300 mm up to 1.500 mm
Colour housing
Grey
Material ABS
Dimensions (H x W x D)
370 mm x 115 mm x 90 mm
General remarks
The following special tubes for


wider ducts are available on


request

300 bis 750 mm

750 bis 1500 mm

1500 bis 3000 mm

Connection on a conventional line or on the loop3000


via TCM 3300 possible
Including potential free change-over contact for alarm
The following special tubes for wider ducts are available on request:
300 to 750 mm / 750 to 1.500 mm / 1500 to 3.000 mm
Tubes in duct widths above 560 mm should be long enough to reach from one
side of the duct to the other If the tube is longer than 900 mm it needs to be
supported by a hole that should be cut in the opposite wall of the air duct to
protect the tube againts vibrations. The tube must be closed with the small red
bung provided. If the duct housing is connected to a TCM 3300, the conventional
line of the TCM must be adjusted as a 12 V line (Jumper setting on TCM PCB)
Only connect one duct detector per TCM 3300

Optical smoke detector Orbis, conventional system

ORM Orbis

Art-No.: 32895
Optical smoke detector for conventional systems with an optical measurement
method for earliest fire detection and indication according to EN 54-7
Integrated smoke detection system with highest reliability for a secure
alarm verification with intelligent logics
Intelligent analysis and disruption mode for the elimination of
false alarms
Alarm output for the triggering of a LED indicator
Multicolour LED for the different operation status
Delivery including protective cover for installation phase and without
detector base

Technical data
Operation voltage
Quiescent current
Alarm current

OC-outputs

Sensitivity
Humidity
Protection class
Colour housing
Material
Dimensions (H x )
Weight
Standards
VdS approval
CE-CPD-number

8,5 up to 33 V DC
65 A
20 mA at 12 V
40 mA at 24 V
1,2 kOhm at negative power for alarm
indicator or piezo buzzer
< 0,15 dB/m
Max. 98 % (non-condensing)
IP 23D
White
Polycarbonate
42 mm x 100 mm
75 g
EN 54-7:2000
G 204039
0832-CPD-0035

Base adapter for surface mounting

DAB 3000

Art-No.: 32444

Base adapter basic

DAB basic

Art-No.: 32779

Detector assurance screw, 30 pcs. MSS


Art-No.: 50437

37

4.6 Addressable manual call points for loop3000 and accessories

Addressable manual call points for


loop3000 and accessories
Features at a glance:
The addressable manual call points correspond
to EN 54-11 and 17
German and international execution of the
housing
Integrated Isolator according to EN 54-17
Automatic and manual addressing mode

Technical data:



Automatic and manual addressing on the loop3000


Integrated Isolator and T-branch option (with type description PL 3300 )
Alarm output for the activation of e.g. a parallel indicator
Functions completely integrated via loop3000 -protocol

Manual call points

loop3000

Operatin voltage

15 to 30 V DC loop powered

OC-outputs

Max. 10 mA for LED-indicator or piezo buzzer

Ambient temperature

-10C to + 60C

Humidity

Max. 95%

Protection class

IP 42

Please find detailed technical information of all components next to your corresponding
contact at www.detectomat.com

38

4.6 Addressable manual call points for loop3000 and accessories

Manual Call Point, with isolator, with LED, ABS, red

PL 3300 PBDH-ABS-R

Art-No.: 31669
Manual Call Point for loop3000 for the manual activation of an alarm with bidirectional Isolator and status display via LED according to EN 54-11 and EN 54-17
Red plastic housing with imprint burning house



Technical data
Weight
Approx. 270 g
Colour housing
Red (RAL 3000)
Material ABS
Dimensions (H x W x D)
135 mm x 135 mm x 33 mm
Standards
EN 54-11, EN 54-17
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20382

Push Button mechanics for the activation of a manual alarm


Activation after smash of the front glass
Integrated reset mechanics
Integrated red alarm-LED

Accessories:
Spare glass Art.-No. 31910
Spare key Art.-No. 40054
General remarks: Suitable for the fitting into extinguishing cabinets

Manual Call Point, with isolator, with LED, ABS, red


VdS approval G 203021

PL 3300 PBD- ABS-R


Art-No.: 30535
Red plastic housing with imprint Feuerwehr

Manual Call Point, with isolator, with LED, ABS, blue

PL 3300 PBD - ABS - B

VdS approval G 203021

Art-No.: 31059

Blue plastic housing with imprint Hausalarm

Manual Call Point, with isolator, with LED, ABS, yellow

PL 3300 PBD - ABS - Y

VdS approval G 203021

Art-No.: 31060
Yellow plastic housing with imprint Lschanlage

Manual Call Point

PL 3300 MCP

Art-No.: 32433
Manual Call Point for loop 3000 for the manual activation of an alarm with
bidirectional Isolator according to DIN EN 54-11, EN 54-17.
Red plastic housing with imprint burning house

Technical data

Manual Call Point mechanics for the activation of a manual alarm


Non-destructive activation and reset via mechanics
Automatic and manual addressing on the loop 3000
Integrated isolator
Functions completely integrated via loop 3000-protocol

Operation voltage
15 to 30 V DC loop powered
Quiescent current
280 A
Alarm current
5 mA
Ambient temperature
-10C to +60C
Humidity
Max. 95 %
Protection class
IP 32
Colour housing
Red (RAL 3000)
Material ABS
Dimensions (H x W x D) 89 mm x 89 mm x 51 mm
CPD-Number 0333-CPD-075280

39

4.6 Addressable manual call points for loop3000 and accessories

Manual Call Point, with isolator, LED, Aluminium, red,

PL 3300 PBDH-ALU-R

VdS approval G 203021

Art-No.: 31668

Manual Call Point for loop3000 for the manual activation of an alarm
with bidirectional Isolator and status display via LED according to EN
54-11 and EN 54-17. Red aluminium housing with imprint burning house



Push Button mechanics for the activation of a manual alarm


Activation after smash of the front glass
Integrated reset mechanics
Integrated red alarm-LED

Accessories:
Spare glass Art.-No. 31910
Spare key Art.-No. 40054
Weatherproof housing Art.-No. 31091

Technical data
Weight
Approx. 495 g
Colour housing
Red (RAL 3000)
Material ABS
Dimensions (H x W x D)
125 mm x 125 mm x 34 mm
Standards
EN 54-11, EN 54-17
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20382

General remarks: Suitable for a wheatherproof housing

Manual Call Point, with isolator, with LED, Alu, red PL 3300 PBD-ALU-R

VdS approval G 203021

Art-No.: 30467
Red plastic housing with imprint Feuerwehr

Manual Call Point, with isolator, with LED, Alu, blue

PL 3300 PBD-ALU-B

VdS approval G 203021

Art-No.: 31061

Blue plastic housing with imprint Hausalarm

Manual Call Point, with isolator, with LED, ABS, yellow

PL 3300 PBD-ALU-Y

VdS approval G 203021

Art-No.: 31060

Yellow plastic housing with imprint Lschanlage

Weatherproof housing for manual call points

WG R

Art-No.: 31091
IP 54, Aluminium, red

Weatherproof housing for manual call points

WG B

Art-No.: 31092
IP 54, Aluminium, blue

HFM SCH M

Art-No.: 31059

Replacement glass, clear

HFM EG

Art-No.: 31910

40

4.7 Addressable input/output modules for loop3000 and accessories

Addressable in-/output modules


for loop3000 and accessories
Features at a glance:
Intelligent Input/Output modules according to
EN 54-17 and EN 54-18
Variety in design
Integrated isolator according to EN 54-17
Automatic and manual addressable
All in- and outputs with non-regenerative
function with one freely programmable input and
one freely programmable output
High flexibility via programmable options

Technical Data:



Automatic and manual addressing on the loop3000


Functions completely integrated via loop3000-protocol
Monitoring of the operating status via loop3000
Independent programming of input and output

Input/Output Modules

loop3000

Operating voltage

15 to 30 V DC loop powered

Ambient temperature

-10C to + 60C

Humidity

Max.: 95%

Please find detailed technical information of all components next to your corresponding
contact at: www.detectomat.com

41

4.7 Addressable input/output modules for loop3000 and accessories

In-/Output module, with isolator

IOM 3311

VdS approval G 205029

Art-No.: 30200

Intelligent Input/Output module for the loop3000 with bidirectional


isolator according to EN 54-18
With one monitored input and one potentialfree relay output

Technical data
Outputs
Low active monitored
Inputs
Low active monitored
Weight
Approx. 185 g
Protection class
IP 54
Colour housing
Grey (similar to RAL 7035)
Material ABS
Dimensions (H x W x D)
93 mm x 93 mm x 55 mm
Standards
EN 54-18, EN 54-17
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20459

Connecting module with one freely programmable input and one freely
programmable output
Programming of different switching variants of input and output also
with time control
Integrated isolator and T-branch option
Multicolour LED for alarm (red) and fault (yellow)
Aestethical robust wall mounted housing according with IP 54

Accessories:

Possibility for monitoring of the output with


UBW 3311 Art.-No. 32073

General remarks: The fault input can be used for the monitoring

module UBW 3311

Input/Output module, single I/O, signalling devices

OMS 3301

VdS approval G 205030

Art-No.: 30211

Properties and technical data like Art.Nr. 30200, however:

Integrated automatic switch function of the output at external


signal line on/off signal by the fire control panel
Connecting module with one freely programmable fault input
and one output for the connection of signalling devices

Monitoring module for IOM and OMS

UBW 3311

VdS approval G 205029, G 205030

Art-No.: 32073

Monitoring module for the use in the modules IOM 3311 and OMS 3301 for the
monitored triggering of external optical and acoustic signalling devices
Add-on module for the direct mounting into the housing of the modules
OMS 3301 and IOM 3311

Technical data
Operation voltage
Outputs

Dimensions (H x W x D)
Weight
System approval

24 V
24 V/1 A monitored
Relays-fault output
20 mm x 38 mm x 35 mm
Approx. 50 g
S 295054, S 210001

Module for the monitoring of one output line with 24 V and up to 1 A for
broken wire and short circuit
Polarity switchover at activation of the output
Integrated fault output for the connection to the monitored input of the
modules IOM and OMS
External voltage supply of 24 V
Circuit board for the integration in the module housings IOM 3311 and
OMS 3301

In-/Output module mini, with isolator

AMD 3311

VdS approval G 206047

Art-No.: 30513

Intelligent Input/Output module mini for the loop3000 with bidirectional isolator for
the integration in special detectors and externally connected modules according
to EN 54-18
Including one monitored input and one open collector output

Technical data
Outputs
1 Open Collector 500 mA

110 mA parallel for

LED-status indication
Inputs
Low active monitored
Weight
Approx. 20 g
Protection class
IP 30
Colour housing
Black
Material ABS
Dimensions (H x W x D)
27 mm x 73 mm x 15 mm
Standards
EN 54-18, EN 54-17
System approval
S 295054, S 208123 and 210001
CE-CPD-number 0786-CPD-20530

Connecting module with one freely programmable input and one freely
programmable output
Additional parallel alarm output (blinking) for the control of a status
indicator (without series resistor))
Programming of different switching variants of input and output also
with time control
Integrated isolator
Completely encapsulated module for the integration in special
applications with control by the loop3000

Housing Mini 25L (Art.-Nr. 53372)

42

4.7 Addressable input/output modules for loop3000 and accessories

Output Modul mini for signalling devices, with isolator

OMS 3301 mini

Art-No.: 31640

Conventional module, 1 conventional zone, with isolator

TCM 3300

VdS approval G 206048

Art-No.: 30205

Intelligent Input module for the connection of one conventional detector zone to
the loop3000 with bidirectional isolator according to EN 54-18
For the connection of conventional detectors with 12 V or 24 V technology

Technical data
Eingang
1 monitored detector zone with

up to 65 mA
Weight
Approx. 190 g
Protection class
IP 54
Material ABS
Colour housing
Grey (similar to RAL 7035)
Material ABS
Dimensions (H x W x D)
93 mm x 93 mm x 55 mm
Standards
EN 54-18, EN 54-17
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20373

Voltage selection for the detector zone supply via jumper on the
module board
External supply of conventional detector zones for the flexible use of
different conventional detectors with different current consumptions
and operation voltages
Possibility for parametrization of short-circuit, wire break, prealarm and
alarm thresholds
Integrated Isolator and T-branch option
Multicolour LED for alarm (red) and fault (yellow)
Aestethical robust wall mounted housing according with IP 54

Intelligente Auswerteeinheit im Modulgehuse

PCA 3000 m

Art-No.: 32477

Technical data
Operation voltage
Interfaces
Outputs



Protection class
Colour housing
Material
Dimensions (H x W x D)
Weight

24 V DC +- 10 %
1 Line port 2 floating contacts
1 Alarm relay normally open 1
A/30 V DC
Fault relay normally close
1 A/30 V DC
IP 54
White
Housing: PC und TPE Cover: PS
93 mm x 93 mm x 55 mm
Approx. 135 g

Module for a connection of intelligent components of the series PL with an integrated unit to evaluate the status of the devices via common relays

Module for a connection of intelligent components of the series PL
Evaluation and indication of alarm via a common alarm relay
respectively a common alarm LED
Evaluation and indication of faults (pollution, messure chamber fault,
input fault, open circuit, short circuit) via a common fault relay
respectively a common fault LED
Complete monitoring of the communication between the PCA 3000 and
the PL devices
Connection of up to 32 devices of the serie PL (all automatic detectors,
PL 3300 MCP, PL 3300 PBD, IOM 3311 only as an input module)
Robust housing with protection class IP 54

Intelligent Evaluation System, base version

PCA 3000 s

Art-No.: 32801

43

4.8 Addressable signalling devices for loop3000 and accessories

Addressable optical/acoustic signalling


devices for loop3000 and accessories
Features at a glance:
The addressable input / output elements correspond to EN 54-3, 17, 18 and 23
Different housings and signalling options
Integrated Isolator according to EN 54-17
Automatic and manual addressing mode
Flexibility with programming and connection variances in the system 3000

Technical data:






Activation, monitoring and supply via loop3000-protocol


Integrated automatic reset function at signal extern signal line on/off by the fire control panel
Monitoring of the operating status via loop3000
Independent programming via autarkic loop-address
Automatic and manual addressing on the loop3000
Integrated Isolator
Functions completely integrated via loop3000-protocol
Signalling devices

loop3000

Operation voltage

15 to 30 V DC loop powered

Ambient temperature

-10C to + 60C

Humidity

Max. 95%

For the calculation/design of the number of loop3000-signalling devices please use the latest
loop calculator version.
Please find detailed technical information of all components next to your corresponding contact
at www.detectomat.com

44

4.8 Addressable signalling devices for loop3000 and accessories

Loopsounder red, with isolator

LS 3300 R

VdS approval G 208103

Art-No.: 31836

Technical data
Operation voltage
15 to 30 V DC loop powered
Quiescent current
280 A
Alarm current
5 mA
Sound level
Max. 97 dB
Ambient temperature
-10 C up to +60 C
Protection class
IP 54
Colour housing
Red
Material ABS
Dimensions (H x )
100 mm x 101 mm
Weight
340 g
Standards
EN 54-3, EN 54-17

Intelligent acoustic signalling device for the loop3000 for the external acoustic
alarm with bidirectional isolator according to EN 54-3
Wall mounted housing, red colour

Activation, monitoring and supply via loop3000-protocol
Integrated automatic reset function at signal external signal line on/off
by the fire control panel
Monitoring of the operating status via loop3000
Independent programming via autarkic loop address
Automatic and manual addressing on the loop3000
Integrated isolator
4 different tones adjustable via DIP-switch (including DIN tone)
Integrated dual tone alarm function via seperate activation possible
Volume control via integrated potentiometer
Functions completely integrated via loop3000-protocol
Aestethical robust wall mounted housing according with IP 54
General remarks: For the calculation/design of the number of

loop3000-signalling devices please use the latest loop

calculator version

Loop3000 - sounder, with Isolator, white

LS 3300 W

VdS approval G 208103

Art-No.: 32012

Loopsounder base, with isolator

LS 3300 VLC

VdS approval G 208144

Art-No.: 32060

Intelligent acoustic signalling device for the loop3000 for the external acoustic
alarm with bidirectional isolator according to EN 54-3.

Technical data
Operation voltage
15 to 30 V DC loop powered
Quiescent current
400 A
Alarm current
6 mA
Sound level
Max. 85 dB
Ambient temperature
-10 C up to +60 C
Protection class
IP 54
Colour housing
Base sounder in white, covers in

red or white
Material ABS
Dimensions (H x )
27 mm x 117 mm
Weight
250 g
Standards
EN 54-3, EN 54-17
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20525

Suitable as wall mounted sounder version or as sounder base for the detector fixed
to the ceiling

Activation, monitoring and supply via loop3000-protocol
Integrated automatic reset function at signal external signal line on/off
by the fire control panel
Monitoring of the operating status via loop3000
Independent programming via autarkic loop address
Automatic and manual addressing on the loop3000
Integrated isolator
32 different tones adjustable via DIP-switch (including DIN tone)
Integrated dual tone alarm function via seperate activation possible
Functions completely integrated via loop3000-protocol
Red or white cover available
For the VdS compliant installation the screw cap must be installed with
the fuse
Accessories: Art.-No. 32067 Cover plate for loop3000 - base sounder, red
Art.-No. 32068 Cover plate for loop3000 - base sounder, white
Art.-No. 32472 Cover ring for loop3000 - base sounder, white
General remarks: When using the cover ring, there is a volume reduction

45

4.8 Addressable signalling devices for loop3000 and accessories

Cover ring for loop3000 - base sounder, white

AD Ring

Art-No.: 32472

Cover for sounder flat red

AD R

Art-No.: 32067

Cover for sounder flat white

AD W

Art-No.: 32068

Loop beacon, orange, with isolator

LB 3300 VXB O

Art-No.: 32090

Loop beacon, red, with isolator

LB 3300 VXB R

Art-No.: 32058
Intelligent optical signalling device for the loop3000 for the external alarm with
bidirectional isolator according to EN 54-23
Wall mounted housing, white colour, red beacon

Activation, monitoring and supply via loop3000-protocol
Integrated automatic reset function at signal
external signal line on/off by the fire control panel
Monitoring of the operating status via loop3000

Technical data
Operation voltage
15 to 30 V DC loop powered
Quiescent current
400 A
Alarm current
6 mA
Ambient temperature
-10 C up to +60 C
Protection class
IP 43
Colour
White housing, red calotte
Material ABS
Dimensions (H x )
80 mm x 98 mm
Weight
145 g

Independent programming via autarkic loop address


Automatic and manual addressing on the loop3000
Integrated short circuit isolator
Integrated 1 Hz LED-beacon
Functions completely integrated via loop3000-protocol
Aestethical robust wall mounted housing according with IP 43
General remarks: For the calculation/design of the number of


loop3000-signalling devices please use the latest


loop calculator

LED indicator, with isolator PA


Art-No.: 32282
Intelligent detector parallel indicator for the loop3000 for the external
optical indication of the installation place of one or more detectors with
bidirectional isolator
White wall mounting housing, red colour

Activation, monitoring and supply via loop3000-protocol
Monitoring of the operating status via loop3000
Independent programming via autarkic loop address

Technical data
Operation voltage
15 to 30 V DC loop powered
Quiescent current
400 A
Alarm current
6 mA
Ambient temperature
-10 C up to +50 C
Protection class
IP 30
Colour
White housing, red calotte
Material ABS
Dimensions (H x W x D)
84 mm x 84 mm x 35 mm
Weight
Approx. 65 g
Standards
EN 54-17
VdS approval
G 208141
System approval
S 295054 and S 208123
CE-CPD-number 0786-CPD-20535

Automatic and manual addressing on the loop3000


Integrated isolator
Functions completely integrated via loop3000-protocol
Aestethical robust wall mounted housing according with IP 30
General remarks: The parallel indicator (Art.-No. 31193) can be connected

directly to the integrated OC-output of the detector for a

direct display of the detector status

46

4.8 Addressable signalling devices for loop3000 and accessories

Sound unit red, with isolator

SDM 3300 R

Technical data
Operation voltage
15 to 30 V DC loop powered
Quiescent current
280 A
Alarm current
1,28 mA; via extern suppy:

9 up to 29 mA
Sound level
Max. 112 dB
Ambient temperature
-10 C up to +60 C
Protection class
IP 54
Colour housing
Red
Material ABS
Dimensions (H x )
93 mm x 93 mm
Weight
340 g
Standards
EN 54-3, EN 54-17

Art-No.: 30204
Intelligent acoustic signalling device for the loop3000 for the external acoustic
alarm with bidirectional isolator according to EN 54-3
Wall mounted housing, colour red

Activation, monitoring and supply via loop3000-protocol
Integrated automatic reset function at signal
external signal line on/off by the fire control panel
Monitoring of the operating status via loop3000
Independent programming via autarkic loop address
Automatic and manual addressing on the loop3000
Integrated Isolator and T-branch option
32 different tones via DIP-switch, including DIN-Tone
Integrated dual tone alarm function via seperate activation possible
Functions completely integrated via loop3000-protocol
Aestethical robust wall mounted housing according with IP 54
General remarks: For the calculation/design of the number of

loop3000-signalling devices please use the latest

loop calculator

Sound unit white, with isolator

SDM 3300 W

Art-No.: 30527

47

5. Conventional Systems

CT 3000
Conventional Technology
The CT 3000 system ist based on conventional technology. Its product range of panels and detectors offers varied
implementation options.

Features at a glance:
Components of the Systems CT 3000 comply with EN 54 - 2, 3, 4, 5, 7, 11 and 23
Easiest management and operation
Flexibility and expandability for various applications
Highest efficiency and cost effectiveness
High variety in design
Please find detailed technical information of all components next to your corresponding contact
at www.detectomat.com

48

5.1 Fire control panels, conventional

DCC Conventional Fire Control Panels


The fire control panels of the series DCC are easy to operate. Clearly arranged control and operation elements
enable a simple operation.
The fire control panels are modular and can be extended by additional modules up to 16 conventional zones.

Technical data:
Clearly arranged display and easy operation via LED-Display and operation keys
Connection possibility for detectors of the series CT 3000 with up to 20 smoke detectors per zone
DCC 2 and DCC 4 with 2 monitored outputs each with 300 mA each for signalling devices; DCC 8plus
with monitored outputs with 300 mA for signalling devices
2 potential free relay outputs for alarm and fault
Independent connection of detector and alarm zones
Emergency current supply via rechargeable battery 1 x 12 V up to 7 Ah
for DCC2 and DCC 4 and up to 12 to 18 Ah for DCC8plus
Integrated one man revision mode
2 access levels via key switch
Manual activation of sirens via separate input
The fire control panels are according to EN 54-2 and -4

Please find detailed technical information of all


components next your corresponding contact at
www.detectomat.com

49

5.1 Fire control panels, conventional

Fire Control Panel, 2 Zones, Conventional, English

DCC 2

Art-No.: 32638
Compact microprocessor controlled fire control panel for the use with the
CT 3000 fire detection system components.
Approved according to EN 54-2: 1997/A1: 2006 and EN 54-4: 1997/A2: 2006




Clear display and easy operation with LED displays and operation keys
Connection possibility for 2 conventional zones for the use with the
CT 3000 fire detection components with up to 20 detectors per zone
Integrated power supply according to EN 54-4: 1997/A2: 2006 with
1 output for external devices rated at 24 V DC

2 monitored outputs with 300 mA each for signalling devices


2 potentialfree relay outputs for alarm and fault
Emergency power supply via 1 battery 12 V/up to 7 Ah
Independent connection of detector and signalling device zones
Integrated one-man-revision mode
2 access levels via key switch
Cable: Maximum cable cross-section of 2,0 mm

Technical data
Supply voltage
Power supply
Emergency supply
Quiescent current
Alarm current
Short circuit
Conventional line broken wire/fault
Display




Outputs





Umgebungstemperatur
Ambient temperature
Stock temperature
Protection class
Farbe

Material
Dimensions (H x W x D)

Weight

Standards

Further approvals

230 V AC 10%
24 V DC/300 mA
1 x 12 V/7 Ah
2 mA up to 10 mA
10 mA bis 110 mA
110 mA
0 bis 2 mA
21 LEDs for status
display, there of 11 LEDs
masked
6 keys for operation,
1 key switch
2 x 24 V/300 mA
monitored for signalling
devices
2 relay outputs 3 A @
60 V DC/3 a @ 120 V AC
for alarm and fault
5C up to +40C
Max. 95 %
-20 C up to +60 C
IP 30
Grey
(similar to RAL 7035)
ABS
288 mm x 340 mm x
98 mm
2,30 kg
(without battery)
EN 54-2: 1997/A1:2006
EN 54-4: 1997/A2: 2006
EVP 1293-CPD-0174

Length: Maximum length of 1.100 meter (0,8 mm)



e. g. JY (ST) Y 2 X 2 X 0,8 mm

Maximum length of 2.700 meter (2,0 mm)

Fire Control Panel, 4 Zones, Conventional, English

DCC 4

Art-No.: 32639

50

5.1 Fire control panels, conventional

Fire Control Panel, 8 - 16 Zones, Conventional, English

DCC 8 plus

Art-No.: 32640
Compact microprocessor controlled fire control panel for the use with the
CT 3000 fire detection system components.
Approved according to EN 54-2: 1997/A1: 2006 and EN 54-4: 1997/A2: 2006
Clear display and easy operation with LED displays and operation keys
Connection possibility for 8 conventional zones for the use with the
CT 3000 fire detection components with up to 20 detectors per zone
Extension option via 4 zone modules for up to 16 conventional zones for
CT 3000 fire detection components
Integrated power supply according to EN 54-4:A2 2006
4 monitored outputs with 300 mA each for signalling devices
2 potentialfree relay outputs for alarm and fault
Emergency power supply via 1 battery 18 V/up to 7 Ah
Independent connection of detector and signalling device zones
Integrated one-man-revision mode
Manual control of signalling devices via seperate input

Technical data
Supply voltage
Power supply
Emergency supply
Quiescent current
Alarm current
Short circuit
Conventional line broken wire/fault
Display




Outputs







Ambient temperature
Humidity
Stock temperature
Protection class
Colour

Material
Dimensions (H x W x D)
Weight
Standards

Further approvals

230 V AC 10%
24 V DC/1 A
1 x 12 V/7 Ah
2 mA up to 10 mA
10 mA up to 110 mA
110 mA
0 up to 2 mA
16 LED-displays for status
display (+ 8 LEDs in case of
extension)
6 keys for operation,
1 key switch
4 x 24 V/300 mA monitored
for signalling devices,
additionally 8 x 24 V/150 mA
monitored during extension
2 relay outputs 1 A @
12 V DC/0,5 A @ 24 V DC
for alarm and fault
-5 C up to +40 C
Max. 95 %
-20 C up to +60 C
IP 30
Grey
(similar to RAL 7035)
ABS
345 mm x 455 mm x 128 mm
4,26 kg (without battery)
EN 54-2: 1997/A1:2006
EN 54-4: 1997/A2: 2006
EVP 1293-CPD-0174

Panel network of max. two fire control panels


Maximum zone length of 2000 m
Cabling: Maximum cable cross-section of 1,5 mm
Accessories: Art.-No. 32653 GE 4: 4 reporting lines extension

Art.-No. 32654 SE 4: 4 signalling devices extension card


Art.-No. 32655 RM8: 4 relay extension module, 8 relays

Rauchmelder
Zone
Expanderoptisch,
Modulemit Isolator, Gitter - Design, silbern GE
PL 3301
4
O silbern

Art-No.: 32653
30488

Rauchmelder
Sounder
Expander
optisch,
Module
mit Isolator, Gitter - Design, schwarz SE
PL 3301
4
O schwarz

Art-No.: 32654
30525

Rauchmelder
Relay
Module optisch, mit Isolator, Glas - Design rund, wei SK
RM 8

Art-No.: 32655
31317

51

5.2 Detectors CT 3000 series, conventional

Detectors of the series CT 3000


The detectors of the series CT 3000 offer a high flexibility in conventional
technology:
Different detection criteria
High variety in design
Housing options for non automatic detectors
Wide range of accessories

Technical data:





Intelligent analysis and disruption mode for the elimination of false alarms
Periodic sensor tests
Alarm output for the triggering of LED indicators
Multicolor LED for alarm (red) and fault (yellow)
Integrated locking system for the protection against removal and tamper
Delivery including protective cover for installation phase

Please find detailed technical information of all components next to your corresponding contact
at www.detectomat.com

52

5.2 Detectors CT 3000 series, conventional

Multisensor detector optical/thermal conventional system

CT 3000 OT

VdS approval requested

Art-No.: 30022

Optical and thermal multi sensor detector for conventional systems


for earliest fire detection and indication in all environments with
difficult ambient conditions according to EN 54-7 and EN 54-5
Integrated professional smoke detection system with highest
reliability for a secure alarm verification with 16 fold measurement and
intelligent logics
Integrated temperature measurement as rate of rise procedure and
maximum value in accordance to EN 54-5

Technical Data
Dimensions (H x )
Standards

52 mm x 100 mm
EN 54-5, EN 54-7

Optical smoke detector

CT 3000 O

VdS approval G 203036

Art-No.: 30015

Optical smoke detector for conventional systems with an optical


measurement method for earliest fire detection and indication according
to EN 54-7
Integrated professional smoke detection system with highest
reliability for a secure alarm verification with 16 fold measurement and
intelligent logics

Technical Data
Dimensions (H x )
44 mm x 100 mm
Standards
EN 54-7
VdS approval
G 203036
System approval
S 295054, S 208123
CE-CPD-number 0786-CPD-20042

Heat detector (fixed and rate of rise temperature)

CT 3000 T

VdS approval requested

Art-No.: 30014

Heat detector with fixed and rate of rise temperature settings for
conventional systems for earliest fire detection and indication in all
environments with difficult ambient conditions according to EN 54-5
Integrated temperature measurement as rate of rise procedure and
maximum value in accordance to EN 54-5

Technical Data
Dimensions (H x )
Standards

52 mm x 100 mm
EN 54-7

53

5.2 Detectors CT 3000 series, conventional

Optical smoke detector, conventional system, Mesh design


VdS approval G 209231

CT 3001 O white
Art-No.: 31929

Optical smoke detector for conventional systems with an optical


measurement method for earliest fire detection and indication according
to EN 54-7. Mesh design, white colour
Integrated professional smoke detection system with highest reliability
for a secure alarm verification with 16 fold measurement and
intelligent logics

Technical Data
Material
Dimensions (H x )
Standards
System approval

ABS, metal mesh


42 mm x 95 mm
EN 54-7
S 295054, S 208123

Optical smoke detector, conventional system, Mesh design


VdS approval G 209231

CT 3001 O silver

Optical smoke detector, conventional system, Mesh design

CT 3001 O black

VdS approval G 209231

Art-No.: 31926

Art-No.: 31589

Optical smoke detector, conventional system, Glass design

CT 3005 O white

VdS approval G 209232

Art-No.: 30551

Optical smoke detector for conventional systems with an optical


measurement method for earliest fire detection and indication according
to DIN EN 54-7. Round glass design, white colour
Integrated professional smoke detection system with highest reliability
for a secure alarm verification with 16 fold measurement and
intelligent logics

Technical Data
Dimensions (H x )
47 mm x 110 mm
Standards
EN 54-7
CE-CPD-number 0786-CPD-20957

Optical smoke detector, conventional system, Glass design

CT 3005 O silver

VdS approval G 209232

Art-No.: 30552

54

5.2 Detectors CT 3000 series, conventional

Optical smoke detector, conventional system, glass design

CT 3006 O white

Art-No.: 32470
Optical smoke detector for conventional systems with an optical
measurement method for earliest fire detection and indication according
to EN 54-7. Square glass design, white colour
Integrated professional smoke detection system with highest reliability
for a secure alarm verification with 16 fold measurement and
intelligent logics

Technical Data
Material
Dimensions (H x W x D)
Standards

Glass, ABS
40 mm x 122 mm x 122 mm
EN 54-7

Optical smoke detector, conventional system, flat design

CT 3007 O white

Art-No.: 32468
Optical smoke detector for conventional systems with an optical
measurement method for earliest fire detection and indication according
to EN 54-7. Round flat design, white colour
Integrated professional smoke detection system with highest reliability
for a secure alarm verification with 16 fold measurement and
intelligent logics

Technical Data
Material ABS
Dimensions (H x )
33 mm x 110 mm
Standards
EN 54-7

Optical smoke detector, conventional system, flat design

CT 3007 O silver

Art-No.: 32469
Round flat design, silver colour

Detector standard base with bridge, white

SDB 3000

Art-No.: 32241
Detector Base with integrated bridge suitable for all detectors of loop3000, white
Integrated wire link between minus contacts for ensurance of a closed
loop at removal of detector
Bridge opens automatically at installation of the detector in the base
Integrated connectors for LED indicator (Art.-No. 31193) or
piezo buzzer Art.-No. 32091
Space for additional connectors Type WAGO 243
Integrated connectors for the connection of one branch for the
loop extension (T-branch)

Technical data
Colour housing
White (similar RAL 9003)
Material ABS
Dimensions (H x )
21 mm x 95 mm

Mounting space for the piezo buzzer (Art.-No. 32091) and the
detector labelling clip Art.-No. 30479
Including transparent seal cover to protect the base against
contaminents

Detector base CT 3000, white

SDB 3000

Art-No.: 30301

Detector base CT 3000, silver

SDB 3000 silver

Art-No.: 30926

Detector base CT 3000, black

SDB 3000 black

Art-No.: 30523

55

5.2 Detectors CT 3000 series, conventional

Detector relay base for CT detectors, white, 24 V

DRB 3000 white

VdS approval G 207011

Art-No.: 30469

Detector base with integrated relay for triggering of external devices or displays
via potential free change over contact for all detectors of series CT 3000
White colour
Triggering of the relays at alarm and removal of detector
Triggering of the relay only at alarm is possible
Compatible to all detetcors of series CT 3000

Technical data

Suitable for the connection to 24 V-systems

Operation voltage
18 up to 30 V DC
Quiescent current
22 mA
Alarm current
0,4 mA
Outputs
1 change over contact 30 V/1
Colour housing
White (similar to RAL 9003)
Material ABS
Dimensions (H x )
55 mm x 113 mm
Weight
Approx. 60 g
System approval
S 295054, S 208123 and S 21001

Space for additional connectors Type WAGO 243


Mounting space for the detector labelling clip Art.-No. 30479

Detector relay base for CT detectors, black, 24 V

DRB 3000 black

Art-No.: 32085

Detector relay base for CT detectors, silver, 24 V

DRB 3000 silver

Art-No.: 32086

Detector relay base for CT detectors, white, 12 V

DRB 400 white

VdS approval G 207011

Art-No.: 32265

Detector base with integrated relay for triggering of external devices or displays
via potential free change over contact for all detectors of series CT 3000
Triggering of the relays at alarm and removal of detector
Triggering of the relay only at alarm is possible
Compatible to all detetcors of series CT 3000

Technical data
Operation voltage
10 up to 15 V DC
Quiescent current
6 mA
Alarm current
0,7 mA
Outputs
1 change over contact 30 V/1
Colour housing
White (similar to RAL 9003)
Material ABS
Dimensions (H x )
21 mm x 95 mm
Weight
Approx. 60 g
VdS approval
G 207011
System approval
S 295054, S 208123 and S 21001

Suitable for the connection to 24 V-systems


Space for additional connectors Type WAGO 243
Mounting space for the detector labelling clip Art.-No. 30479

Detector relay base for CT detectors, silver, 12 V

DRB 400 silver

Art-No.: 32266

56

5.2 Detectors CT 3000 series, conventional

Manual Call Point, conventional system, ABS, red

CT 3000 PBDH-ABS-R

VdS approval G 296033

Art-No.: 31675

Manual Call Point for conventional systems for the manual activation
of an alarm and status display via LED according to EN 54-11
Red plastic housing with imprint burning house
Push Button mechanics for the activation of a manual alarm
Integrated reset mechanics (operation from inside)
Integrated red alarm-LED
Lockable plastic housing

Technical Data
Operation voltage
12 V to 24 V DC
Ambient temperature
-10 C up to +60 C
Protection class
IP 42
Colour Housing
Red (RAL 3000)
Material ABS
Dimensions (H x W x D)
135 mm x 135 mm x 33 mm
Standards
EN 54-11
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20526

Accessories:
Spare glass Art.-No. 31910
Metal key Art.-No. 40054
General remarks:
A plastic key comes with every 10 manual call points

Manual Call Point, conventional system

CT 3000 PBD-ABS-B

Art-No.: 31651

ABS, blue, house alarm

Manual Call Point, conventional system, IP 66, red

CT 3000 PBD-IP66-R

VdS approval G 206113

Art-No.: 31083

Manual Call Point for conventional systems for the manual activation
of an alarm according to EN 54-11.
Red housing with imprint burning house
Push Button mechanics for the activation of a manual alarm
Integrated reset mechanics (operation from inside)
Flame and UV resistant plastic housing

Technical Data
Operation voltage
12 V to 24 V DC
Ambient temperature
-35 C up to +60 C
Protection class
IP 66
Colour housing
Red (RAL 3000)
Material PC
Dimensions (H x W x D)
135 mm x 135 mm x 61 mm
Weight
475 g
Standards
EN 54-11
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20309

57

5.2 Detectors CT 3000 series, conventional

Manual Call Point, conventional system, aluminium, red

CT 3000 PBDH-ALU-R

VdS approval G 202034

Art-No: 31676

Manual Call Point for conventional systems for the manual activation
of an alarm and status display via LED according to EN 54-11.
Red aluminium housing with imprint burning house
Push Button mechanics for the activation of a manual alarm
Integrated reset mechanics (operation from inside)
Integrated red alarm-LED
Lockable plastic housing

Technical Data
Operation voltage
15 V to 30 V DC on two-wire bus
Ambient temperature
-10 C up to +60 C
Protection class
IP 42
Colour housing
Red (RAL 3000)
Material Aluminium
Dimensions (H x W x D)
125 mm x 125 mm x 34 mm
Standards
EN 54-11, EN 54-17
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20382

Accessories:
Spare glass Art.-No. 31910
Metal key Art.-No. 40054
Weatherproof housing Art.-No. 31091

Manual Call Point, conventional system, Aluminium


CT 3000 PBD-ALU-B
Art-No.: 31087
Blue aluminium housing with imprint house alarm

Manual Call Point, conventional system, Aluminium


CT 3000 PBD-ALU-Y
Art-No.: 31088
Yellow aluminium housing with imprint extinguishing system

Manual Call Point, conventional system, Aluminium


CT 3000 PBD-ALU-OR
Art-N0.: 31089

Orange aluminium housing with imprint flue

58

5.3 Signalling devices optical/acoustic, conventional

Multiple tone sounder, red

CS 200 R

Art-No.: 31689
Acoustic multiple tone sounder for an external acoustic alarm according
to EN 54-3
32 different tones (incl. DIN tone) adjustable via DIP button
Automatic synchronisation
Integrated two tone alarm function
Flat design

Technical Data
Operation voltage
9 to 28 V
Alarm current
15 mA bei DIN-Ton
Volume
Max. 102 dB at DIN tone

Max. 112 dB
Ambient temperature
-10 C up to +55 C
Protection class
IP 21C
Colour housing
Red
Material
ABS FR
Dimensions (H x )
63 mm x 63 mm
Weight
240 g
Standards
EN 54-3
System approval
S 295054, S 210001
CE-CPD-number 0832-CPD-0523

Multiple tone sounder, white

CS 200 W

VdS approval G 209123

Art-No.: 31690

Multiple tone sounder, red

ROLP 32 R

VdS approval G 206019

Art-No.: 31838

Acoustic multiple tone sounder for an external acoustic alarm according


to EN 54-3
32 different tones (including DIN tone) adjustable via DIP button
Automatic synchronisation
Volume internally adjustable
Integrated two tone alarm function
Flat design

Technical Data
Operation voltage
9 to 28 V
Volume
64 to 111 dB, 99 dB at DIN tone
Ambient temperature
-25 C up to +70 C
Protection class
IP 54
Colour housing
Red
Material
ABS FR
Dimensions (H x )
63 mm x 93 mm
Weight
250 g
Standards
EN 54-3
VdS approval
G 206019
System approval
S 295054, S 210001
CE-CPD-number 0832-CPD-0128
Further approvals
LPCB, CNPP, UL

Accessories
Art.-No. 40059: Flush-mounted base for IP 65, red, type UB r
Art.-No. 31468: Flush-mounted base 48 mm for IP 65, red, type PG DG r

Mulltiple tons ounder, white

ROLP 32 W

VdS approval G 206019

Art-No.: 30198

59

5.3 Signalling devices optical/acoustic, conventional

Multiple tone sounder, red

SYS 120 R

VdS approval G 206027

Art-No.: 30216

Acoustic multiple tone sounder for an external acoustic alarm according


to EN 54-3
32 different tones (incl. DIN tone) adjustable via DIP button
Automatic synchronisation
Volume internally adjustable

Technical Data

Integrated two tone alarm function

Operation voltage
9 to 28 V
Alarm current
190 bis 260 mA, 240 mA at DIN tone
Volume
88 to 120 dB, 112 dB bei DIN Ton
Ambient temperature
-25 C up to +55 C
Protection class
IP 42
Colour housing
Red
Material
ABS FR
Dimensions (H x W x D)
96 mm x 108 mm x 108 mm
Weight
210 g
Standards
EN 54-3
System approval
S 295054, S 210001
CE-CPD-number 0832-CPD-0142

Flat design
General remarks :
Protection class IP 65 available on request

Parallel indicator PA

VdS approval G 208142

Art-No.: 31193
Detector parallel indicator for the external optical indication of the
installation place of one or more detectors
White wall mounting housing, red colour
Aestethical robust wall mounted housing according with IP 30

Technical Data
Operation voltage
7 to 35 V DC
Alarm current
4 mA
Ambient temperature
-15 C to +50 C
Protection class
IP 30
Colour housing
white housing, red calotte
Material ABS
Dimensions (H x W x D)
84 mm x 84 mm x 35 mm
Weight
Approx. 65 g
System approval
S 295054, S 208123 and S 210001
CE-CPD-number 0786-CPD-20804

Beacon, red

Solex 10 r

VdS approval G 207018

Art-No.: 32462
Optical Xenon - beacon for an external optical alarm according to EN
54-23
Huge input voltage range
Automatic synchronisation
Integrated starting current limitation

Technical Data
Operation voltage
Alarm current
Efficacy
Ambient temperature
Protection class
Colour housing
Material
Dimensions (H x )
Weight
Standards
System approval
CE-CPD-number

10 to 60 V DC
45 bis 185 mA, 80 mA bei 24 V
10 Cd
-25 C up to +70 C
IP 54
Red
Base ABS, lense PC
67 mm x 93 mm
150 g
EN 54-23
S 295054, S 208123 and S 210001
Not until 2013

High efficiency
Flat design
Accessories
Art.-No. 40059: Flush-mounted base for IP 65, red, UB r
Art.-No. 31468: Flush-mounted base 48 mm for IP 65, red PG DG r

60

5.3 Signalling devices optical/acoustic, conventional

Beacon, orange

Solex 10 o

VdS approval G 207018

Art-No.: 30220
For optical beacon Solex and acoustic beacon Rolp

Beacon, green

Solex 10 g

VdS approval G 207018

Art-No.: 32447

Beacon, blue

Solex 10 b

VdS approval G 207018

Art-No.: 32448

Flush mounted base, red

UB r

Art-No.: 40059
For optical beacon Solex and acoustic beacon Rolp

Flush mounted base, white

UB w

Art-No.: 40060
For optical beacon Solex and acoustic beacon Rolp

Construction mounted base, red

PG DB r

Art-No.: 31467
For optical beacon Solex and acoustic beacon Rolp

Construction mounted base, white

PG DB w

Art-No.: 31468
For optical beacon Solex and acoustic beacon Rolp

Beacon, wei

BLZ-03 w

VdS approval G 201071

Art-No.: 30267
Optical Xenon - beacon for an external optical alarm according to EN
54-23
Two different tones
Low power consumption
Integrated electrical surge
Wall and ceiling mountable
Lines are introduced from the bottom or side
Automatic synchronization
Can be used indoors and outdoors
High efficiency

Technical Data
Operation voltage
Flash frequenency
Ambient temperature
Protection class
Colour calotte
Material

Dimensions (H x )
Weight
Standards

12 to 24 V
1 Hz
-10 C up to +70 C
IP 54
Transparent
Base ABS
Calotte Makrolon
108 mm x 108 mm x 70 mm
150 g
EN 54-23

Flat design

61

6.1 Special detectors and accessories

Special detectors and accessories


In this chapter products are presented, which are required for the detection of fires under special conditions.
The special specifications of individual applications and detailed accessories are not considered in this chapter.
Details can be obtained with your responsible sales contact.

Linear smoke detectors and accessories


Smoke aspiration systems and accessories
Linear heat detectors and accessories
Flame detectors and accessories
Explosion proofed detectors and signalling
devices
Test equipment
Please find detailed technical information of all
components next your corresponding contact at
www.detectomat.com

62

6.1 Special detectors and accessories

HSSD-2 smoke aspiration detector with display

HSSD-2 M

VdS approval G 203024

Art-No.: 31114

Intelligent active laser - smoke aspiration detector for ealiest


detection of fires in sensitive and extreme contaminated areas e.g.
EDP-control room, hospital operating room, storage area, incineration
plant, etc.

Technical Data
Operation voltage
Outputs

Measurement range

Particle sensitivity range
Protection class
Pipe diameter
Colour housing
Material
Dimensions (H x W x D)
Weight
Standards
System appoval
Further approvals

21,6 to 26,4 V DC
5 potential free relays for info,
prealarm, fire 1, fire 2, fault
0,03 to 25 % obs/m
0,0003 m to 10 m
IP 50
3/4
Light grey
Cast aluminium/ABS
372 mm x 427 mm x 95 mm
5,2 kg
EN 54-20
S 295054 and S 208123
LPCB, CCC

Integrated LC-Display with 2 x 16 characters, arrow keys control panel


Integrated automatic adjustment of the detector to the ambient
conditions via intelligent teach in modes
Intelligent laser sensor technology with consideration of ambient
conditions for fast detection in difficult environments
Highest reliability by optimal adjustment of the alarm threshold via
intelligent algorithm for the fire detection
Unwanted alarms from dust are avoided using patented Dual
Technology LDD 3D3, Laser dust discrimination and elimination system
Automatic day-/night mode for the adjustment from and to temporally
different ambient conditions
Integrated fast learn for the automatic configuration of the system
Special integrated technology for the elimination of influences by
pollution (dust etc.)
Integrated dust filter
Integrated RS 485-interface for the network of up to 127 participants
Integrated potential free relays outputs for alarm and fault
External voltage supply required
Functions completely integrated via loop3000-protocol
4 sampling pipes, up to 250 m maxium length:
- Total pipe length 200 m with up to 100 sampling holes
- Total pipe length 250 m with up to 80 sampling holes

HSSD-2 smoke aspiration detector without display

HSSD-2 MOD

Art-No.: 31867

HSSD-2 smoke aspiration detector with display



and command unit

Art-No.: 31115

HSSD-2 MS

HSSD-2 command unit

HSSD-2 S

Art-No.: 31117

HSSD-2 command unit with power supply unit

HSSD-2 SN

Art-No.: 31116

63

6.1 Special detectors and accessories

Micra 100 with mounting base

Micra 100

VdS approval G 209217

Art-No.: 31476

Intelligent active laser - smoke aspiration detector for ealiest


detection of fires in sensitive and extreme contaminated areas e.g.
EDP-control room, hospital operating room, storage area, incineration
plant, etc.

Technical Data
Operation voltage
Current consumption
Measurement range
Particle sensitivity range
Protection class
Pipe diameter
Dimensions (H x W x D)
Standards

21,6 to 26,4 V DC
400 mA at 24 V DC
0,03 to 25 % obs/m
0,0003 m to 10 m
IP 50
3/4
200 mm x 293 mm x 83 mm
EN 54-20

Integrated automatic adjustment of the detector to the ambient conditions via


intelligent teach in modes
Intelligent laser sensor technology with consideration of ambient conditions for
fast detection in difficult environments
Highest reliability by optimal adjustment of the alarm threshold via intelligent
algorithm for the fire detection
Unwanted alarms from dust are avoided using patented Dual Technology
LDD 3D3, Laser dust discrimination and elimination system
Automatic day-/night mode for the adjustment from and to temporally different
ambient conditions
Integrated fast learn for the automatic configuration of the system
Special integrated technology for the elimination of influences by pollution
(dust, etc.)
Integrierter Staubfilter
2 sampling pipes, up to 100 m maximun length:
- Total pipe length 100 m with up to 25 sampling pipes
- Total pipe length 2 x 50 m with up to 25 sampling pipes
Integrated dust filter
1 recirculation pipe for the compensation of the intrasystem pressure gradient
Integrated RS 485-interface for the network of up to 127 participants
External voltage supply required
Functions completely integrated via loop3000-protocol
Including mounting base and connection flange for the recirculation pipe

Accessories:
Relais board Art.-No. 32236 with 5 potential free relays outputs

Micra 100 with mounting basee and relays card

Micra 100 REC

VdS approval G 209217

Art-No.: 32330

Micra 25 with mounting base

Micra 25

VdS approval G 207078

Art-No.: 31118

Features and technical data similar to Art.-No. 31476


1 sampling pipe, up to 50 m maximun length:
- Total pipe length 50 m with up to 10 sampling pipes
(25 m at highest sensitivity)

Technical Data
Current consumption
Dimensions (H x W x D)
System approval
Further approvals

Micra 25 with mounting base and relays card

Micra 25 REC

VdS approval G 207078

Art-No.: 32313

Relais board REC


Art-No.: 32236

64

250 mA at 24 V DC
175 mm x 135 mm x 83 mm
S 295054 and S 208123
LPCB, CCC

6.1 Special detectors and accessories

Air filter replacement for HSSD-2

ELF HSSD-2

Art-No.: 31255

Air filter replacement for Micra

ELF Micra

Art-No.: 31256

Air filter replacement for HSSD-1

ELF HSSD-1

Art-No.: 31253

Pipe AR

Art-No.: 31133

Angle 45 W45

Art-No.: 31135

Bend 90 B90

Art-No.: 31136

Connection sleeve VM

Art-No.: 31138

T-pipe TA

Art-No: 31140

Screw joint VG

Art-No.: 31141

End cap EK

Art-No.: 31143

Reducing socket RA

Art-No.: 31950

Mounting clip for pipe BC


Art-No.: 31145

Suspension for mounting clip AB


Art-No.: 31146

Hose pipe, red KR


Art-No.: 31151

Hose pipe, white KW


Art-No.: 31152

Flange nut for mounting clip FM


Art-No.: 31960

T-house pipe adapter TKA


Art-No.: 31153

End adapter for hose pipe EKA


Art-No.: 31154

65

6.1 Special detectors and accessories

End piece for hose pipe FK


Art-No.: 31156

End piece for hose pipe KK


Art-No.: 31155

Warning decal for sampling holes, 100 pcs. WA


Art-No.: 31149

Smoke pen RS

Art-No.: 32334

Smoke generator

AX 18

IR-Beam detector

Art-No.: 31539

FR 2000

VdS approval G 297058

Art-No.: 31095
Infrared beam detector for the detection of light and dark beam with
sender, receiver and separate analyser







Detection of light and dark smoke


Range 5 to 100 m
Control width: max. 13 m
Control height: max. 12 m
Control area: 1300 m
Potential free relays for alarm and fault
Three sensitivities: 25 %, 35 % and 50 %
Connection to the loop3000 via IOM 3311

Technical Data
Operation voltage
11,5 V DC to 28 V DC
Quiescent current
< 8 mA at 24 V DC
Alarm current
< 16,5 mA at 24 V DC
Output relais
2 x 30 V DC/1 A
Ambient temperature
-20 C up to +55 C
Protection class
IP 50
Colour housing
White (similar to RAL 9010)
Dimensions (H x W x D)
265 mm x 210 mm x 88 mm
Standards
EN 54-12
System approval
S 295054, S 208123
CE-CPD-number 0786-CPD-20196

66

6.1 Special detectors and accessories

Infrared beam detector, incl. 1 prism

FR 5000

VdS approval G 208017

Art-No.: 32476

Infrared Beam Detector with automatic adjustment by an infrared


sender and receiver unit including a reflection prism. The Fireray
5000 requires 1 prism for the range of 8-50 m and 4 prism for the
range of 50 to 100 m

Technical Data
Operation voltage
14 to 28 V DC
Quiescent current
8 to 12 mA
Alarm current
48 to 52 mA
Ambient temperature
-10 C up to +55 C
Protection class
IP 54
Dimensions (H x W x D)
135 mm x 134 mm x 134 mm

(sender/receiver)
Standards
EN 54-12
System approval
S 295054, S 208123
CE-CPD-number 0832-CPD-0565

Modular design
Adjustment of the system to the local conditions
Automatic adjustment of the beam detector can be activated or
deactivated
LCD display with optical menue navigation in the display for an easy
operation
2 m wire interface between smoke detector and system controller
Adjustment of the sensitivity with threshold values in the range of
10 % to 60 %
Connection to the loop3000 via IOM 3311
Adjustment of the delay times individually for fire and fault from 2 to 30
seconds
Automatic compensation for moving buildings
The scope of delivery includes a detector unit, a control unit and a
prism
Accessories: Reflection prism Art.-No. 32471

Detector unit for IR-Beam detector

ME FR 5000

IR-Beam detector

Art-No.: 32741

FR 50 RV

VdS approval G 203070

Art-No.: 31861
Infrared beam detector for the detection of light and dark beam with
sender and receiver in a single housing, including four prism

Technical Data
Operation voltage
10,2 to 30 V DC
Quiescent current
< 4 mA
Alarm current
< 15 mA
Output relais
2 x 30 V DC/1 A
Ambient temperature
-30 C up to +55 C
Protection class
IP 50
Dimensions (H x W x D)
210 mm x 126 mm x 120 mm
Standards
EN 54-12
VdS approval
G 203070
System approval
S 295054, S 208123
CE-CPD-number 0786-CPD-20045

Detection of light and dark smoke


Range 5 up to 50 m
Monitored area and mounting accord. to DIN VDE 0833
Potential free relays for alarm and fault
Three sensitivities: 25 %, 35 % and 50 %
Connection to the loop3000 via IOM 3311
Automatic compensation of pollution

Accessories: Reflection prism Art.-No. 32471

Infrared beam detector

FR 100 RV

VdS approval G 203070

Art-No.: 31486

Features and technical data similar to Art.-No. 31861, including four prism
Range 50 up to 100 m

Extension prism

EP 01

Art-No.: 32471

67

6.1 Special detectors and accessories

1 Prism-mounting plate MPP1


Art-No.: 32742

4 Prism-mounting plate MPP4


Art-No.: 32743

Universal bracket for Beam detectors UH


Art-No.: 32850

Linear heat cable detector LWM-1


VdS approval G 205066

Art-No.: 32315
Linear heat sensor cable detector for the earliest detection of fire or
overheating in critical environments

Technical Data
Operation voltage
Alarm current
Potential free relays
Protection class
Dimensions (H x W x D)

10 to 30 V DC
28 mA (at 24 V)
2 x 30 V/1 A DC
IP 65
105 mm x 105 mm x 65 mm

Application e.g.: garages, tunnels, parking houses, escalator,


conveyors, cable ducts, cold store, high voltage plants, recycling
plants etc.
For the connection of up to 300 m sensor cable
Connection of cables resistant against mechanical, chemical and
biological influences
Adjustment of the sensitivity of the linear heat cable detector via
16 stage DIP-switch with free adjustment of fixed and rate of rise
temperature
Three potential free relay contacts for the connection to the fire control
panel via IOM 3311 module, 2 alarm relays, 1 fault relay
Test key for simulation, alarm, fault and LED test
Monitoring of wire break and short circuit
Connection to the loop3000 via IOM 3311
Suitable for detection in classes A1, A2, B and C
Suitable for the use in Ex zones (Zone 1 and Zone 2; Zone 21 and
Zone 22)

Linear heat cable LWM-1, blue SKB


VdS approval G 205066

Art-No.: 32316

Linear heat cable LWM-1, black SKS


VdS approval G 205066

Art-No.: 32317

Linear heat cable LWM1, black with steel netting mesh SKSS

VdS approval G 205066

Art-No.: 32318

Exclusion connector for linear heat cable AVB


Art-No.: 32319

Interconnector for linear heat cable ZVB


Art-No.: 32320

68

6.1 Special detectors and accessories

Linear heat cable detector SKM-03.01


Art-No.: 30503
Linear heat sensor cable detector for the earliest detection of fire or
overheating in critical environments

Technical Data
Operation voltage
Alarm current
Potential free relays
Protectonc class
Dimensions (H x W x D)

24 V DC
28 mA
2 x 30 V/1 A DC
IP 65
110 mm x 110 mm x 66 mm

Application e.g.: garages, tunnels, parking houses, escalator,


conveyors, cable ducts, cold store, high voltage plants, recycling
plants etc.
For the connection of up to 300 m sensor cable
Connection of cables being resistant against mechanical, chemical and
biological influences
External 24 V supply required
Potential free alarm and fault output
Connection to the loop3000 via IOM 3311
Monitoring of wire break and short circuit

Linear heat cable, red SKM-KRT


Art-No.: 30980

Linear heat cable, black SKM-KSW


Art-No.: 30981

Fastening clamp, 100 pc. SK-LS


Art-No.: 31620

Infrared flame detector

X 9800

Art-No.: 32075
Infrared flame detector for a secure detection of e.g. hydrocarbon
fires in industrial applications like turbine, petrochemistry, automotive
industry, projects with high pollution

Technical Data
Operation voltage
Alarm current
Interfaces
Potential free relays
Sensitivity



Protection class
Dimensions (H x W x D)
Standards
AREX-Number

18 V to 30 V DC
550 mA
RS-485 Modbus output, 4-20 mA
Alarm, Fault, additional alarm
N-Heptane: 0,1 m in 15 m
distance: < 15 seconds
Methan: 30 inch flame in 10,5 m
distance: < 10 seconds
IP 66
119 mm x 122 mm x 246 mm
EN 54-10; Cl. 1-3
538 Ex II 2 GD, TEX 132195, FM 3260

Fast response time (40 ms)


Visual range angle 90
Multicolour LED for status display of operation, fault and alarm
Mounting bracket vibration-free according to MIL
Event memory
Maintenance mode via magnet
Modular housing design
Hazardous area proof: EX: 538 Ex II 2 GD, AREX 132195, FM 3260
Monitoring of wire break and short circuit

Scope of supply:
detector, magnet and mounting bracket
Recommended cable:
shielded cable with 0,5 mm up to 2,5 mm

69

6.1 Special detectors and accessories

UV-flame detector

FMX 5000 UV

Art-No.: 32272
Conventional ultraviolet flame detector for the detection of open
flames (e.g. fire with gas, oil products, plastic, wood, metal)

Technical Data
Operation voltage
Quiescent current
Alarm current
Protection class
Dimensions (H x )
Covering range
Covering area
Max. cable length
Standards
General remarks


7,6 V to 30 V DC
Approx. 0,25 mA
Approx. 15 mA
IP 67
100 mm x 50 mm
Up to 50 m
Up to 676 m
700 m with 0,5 mm cable
EN 54-10; Cl. 1
Up to 8 FMX 5000 UV-flame
detectors can be connected to one
conventional interface CP CLI or to one
conventional module TCM 3000

The ultraviolet light of the optical spectrum is analysed


Robust housing suitable for the application in rough industrial
environment
High reliability against false alarms, like e.g. ligthning or strong solar
irradiation
High sensitivity
Covering range up to 50 m; Covering area up to 676 m
Parametrization for different applications via DIP switch
Monitoring of the optical window against pollution (UV-range)
Function control and analysis of the measured values with
microcontroller; faults can be displayed at the detector or at a
separate line
Multicolour LED for alarm (red) and fault (yellow)
Recomended cable: IY (St) Y 2x2x0,8 mm
Including service interface and event memory
Including mounting base and mounting bracket

EX Multi sensor detector optical - heat, conventional systems

MSM EX Orbis IS

VdS approval G 207028

Art-No.: 32244

EX heat detector, conventional systems

WM EX 50 Orbis IS

VdS approval G 207020

Art-No.: 32245

EX optical detector, conventional systems

OM EX Orbis IS

VdS approval G 207027

Art-No.: 32246

EX detector base for Orbis detectors, conventional systems

MS EX Orbis IS

VdS approval G 207020

Art-No.: 32247

EX Multiple Tone Sounder, conventional systems

IS-A 105N

Art-No.: 32306

EX-barrier for EX-Multiple Tone Sounder, conventional system


Z 728
Art-No.: 32307

EX-barrier for EX-detectors, conventional systems Ex-B1


Art-No.: 31174

EX Manual Call Point, conventional systems HFM-Ex


Art-No.: 31170

Spare glass for HFM-EX

Spare glass

Art-No.: 31269

EX-beacon, red

BE 24 R EEX

Art-No.: 31222

EX-beacon, yellow

BE 24 Y EEX

Art-No.: 31223

Housing for modules M-1


Art-No.: 30218

70

6.1 Special detectors and accessories

Heat and smoke detector tester/complete

Testifire 1001-001

Art-No.: 32335
Cordless test set for heat detectors and smoke detectors



1 cordless combi test cap 1001-01


1 test capsule TS3-001 smoke capsule
2 battery bars Solo 760-001
1 battery charger

Heat, smoke and CO-detector tester, complete

Testifire 2001-001

Art-No.: 32336
Cordless test set for heat detectors, smoke detectors and CO detectors



1 cordless combi test cap 1001-01


1 test capsule TS3-001 smoke capsule
2 battery bars Solo 760-001
1 battery charger

Test capsule TC3-001 CO

Test set smoke/heat with exchange tool, telescope pole/bag

Testifire 6001-001

Art-No.: 32389
Cordless smoke tester with multi-triggering for smoke- and heat
sensors






1 cordless combi test cap 1000-01


1 test capsule TS3-001 smoke capsule
2 battery bars Solo 760-001
1 battery charger Solo 725-001
1 glass fibre telescope pole to 4,5 m extensible Solo 1001-001
1 extraction tool / Pick cap Solo 200-001
1 transport bag Solo 610-001

Test set smoke/heat/Co with exchange tool/telescope pole/bag

Testifire 6201-001

Art-No.: 32388
Cordless smoke tester with multi-triggering for smoke-, heat- and
CO sensors







1 cordless combi test cap 1000-01


1 test capsule TS3-001 smoke capsule
1 test capsule TC3-001 CO capsule
2 battery bars Solo 760-001
1 battery charger Solo 725-001
1 glass fibre telescope pole to 4,5 m extensible Solo 1001-001
1 extraction tool / Pick cap Solo 200-001
1 transport bag Solo 610-001

71

6.1 Special detectors and accessories

Replacement smoke capsule (6 pc.)

Testifire TS3-001

Art-No.: 32337
Replacement smoke capsule TC3-001

Replacement CO-capsule (6 pc.)

Testifire TC3-001

Art-No.: 32338
Box with 6 capsules for the test of CO-detectors

Smoke detector test set

SOLO 812

Art-No.: 31956
Test and detector exchange for all smoke detectors




1 glass fibre telescope extension pole, length 4,5 m


2 glass fibre extension poles, length 4,5 m
1 universal removal tool for the exchange of detectors
1 aerosol smoke dispenser
1 protective carrying/storage bag

Smoke detector test set

SOLO 330

Art-No: 14008
Smoke dispenser for the release of smoke test aerosol for the activation of optical
detectors
Clear test cap for the visual control of the detector LED during smoke test
Spring loaded mechanism for effective, economic areosol release
Test cap sensitive to pressure - ideal for suspended/false ceilings

Heat detector tester, complete

SOLO 461

Art-No.: 30398
Cordless test set for heat detectors
1 cordless heat detector test cap
2 battery bars
1 battery charger

Detector exchange tool

SOLO 200

Art-No.: 14007
Detector removal tool for an easy replacement of detectors

72

6.1 Special detectors and accessories

Telescope pole

SOLO 100

Art-No.: 14006
Telescope extension pole of glass fibre
4 section glass fibre telescope pole
Extendable to 4,5 m

Extension pole

SOLO 101

Art-No.: 30193

Bag

SOLO 610

Art-No.: 14010
Carrying/Storage bag for test equipment
Integrated package
Black synthetic material
With carrying strap

Technical Data
Dimensions (H x W x D)

Testaerosol 250 ml

460 mm x 45 mm x 180 mm

TA 250

Art-No.: 31845
Non flammable testaerosol for ionisation and optical smoke detectors










250 ml bottle
In inflammation, the product collapse to carbon oxides
Residue formation: Clean, non greasy, (oil free formula), fast evaporating
Pressure:
20 C ~ 6 bar ( ~ 87 psig),

50 C ~ 11 bar ( ~ 159 psig)
Product density:
20 C, 1,02 g/ml (63,67 lb/ft3)
Flame point:

12 C
Vapour density:
(Air = 1) > 1
Solubility:

In water partly soluble
Ambient temperature: 0 C up to +40 C
Non flammable non self-sparking

To avoid extreme heat, direct sunlight, strong oxidisers, strong acids, bases and
alkali metals

Testaerosol 35 ml

TA 35

Art-No.: 32262

73

7. Voice evacuation systems

Voice Evacuation System


sound detect
There are different terms of general linguistic usage given for voice evacuation systems.
Using a system to alarm and evacuate individuals in combination with a fire control panel, the system itself is
called Voice Evacuation System (EVAC).
EVAC systems provide individuals with information about the hazardous situation, risk or important event and will
provide them with specific instructions for their self-rescue. EVAC systems are integral parts of fire prevention
conception and offer automatic detection with automatic voice evacuation.
The detectomat components of the system sound detect are certified according to EN 54-16 (voice alarm panels)
and EN 54-24 (components for voice alarm systems). For approval according to European Standard, the system
was extended by some components. These components offer EN-54 conform project work and installation of voice
alarm system.
In all cases, we recommend an all-over documentation plus a co-ordination with the approving authority
for the system. In addition to the supply of the components, detectomat offer supply of complete and
approved panels according to CE-CPD- and VdS-G labelling.
Components to be used and corresponding procedure, please see installer manual.

Please find detailed technical information of all components next


to your corresponding contact at www.detectomat.com

Voice Alarm Panel / System


Speakers
Accessories

74

7.1 Voice evacuation system sound detect

System controller Pantura

SD - PCT 622 L

VdS approval G 211073

Art-No.: 32407
PCT 622 L system control unit for the Pantura EVAC-system for the management
of up to 6 paging stations and 2 audio-inputs and 2 audio-outputs
Integrated audio matrix with 6 connections for paging stations, 2 audio
inputs for external auxiliaries and 2 audio outputs for the processing in
the speaker matrix
Interface connection for the Fire Control Panels of the
system detect 3000 via 8 independent and freely programmable inputs

Technical data
Operation voltage
Power consumption with
unloaded interfaces

Input-/output level paging stations
Input level line-in



Output level line-out
Slave clocks supply voltage
Slave clocks output current
Power consumption with
unloaded interfaces
Mounting
Colour housing
Material
Dimensions (H x W x D)


Weight

18 to 36 V DC
low: -30 to +5 V DC
high: +10 to +30 V DC
+6 to +8dBu
Position +6dBu:
+6 to +8dBu
Position -12dBu:
-12 to -8dBu
+6 to +8dBu
12 to 60 V DC
Approx. 800 mA
25 to 30 W
19 - fitting
Silver grey
Metal
44,4 mm (1 HE) x 483 mm
(19) x 240 mm
Approx. 3,7 kg

Intelligent voice management for an optimal routing of the


corresponding audio signals
Internal flash memory (128 MB) for wave-files for different voice
recordings or alarm signals with a maximum duration of 9 minutes
Scaleable audio memory for voice messages and evacuation signals
Permanent monitoring of all audio and control paths, processors,
memories, paging stations, decentralized modules, active error
interface and the display for individual error messages
Control and management of up to 30 speaker Matrix SD - PMT 32
Management of up to 240 speaker lines, 256 paging zones and
120 power amplifiers per controller
Dynamic power management of all amplifier channels
Integrated real time clock for time and calendar functions and
system messages
Optional time synchronisation via DCF 77 or GPS signals
Built in master clock for management of different varying slave clocks
User friendly and high performance PC programming software with
integrated online-help for an easy programming of the system via
Ethernet interface
Password protected access rights via programming software P-Control
Remote access via LAN or ISDN
Integrated Ethernet-interfaces
Incl. USB or Parallel Interface for the connection of a printer
Factory provided serial number for addressing in the system

System controller Pantua 622 LFO, fibre optic interface

SD - PCT 622 LFO

VdS approval G 211073

Art-No.: 32408

System controller Pantura 1244 L

SD - PCT 1244 L

VdS approval G 211073

Art-No.: 32409

Properties and technical data like Art.No. 32409, however:

PCT 1244 L system control unit for the Pantura EVAC-System for the
management of up to 12 paging stations and 4 audio-inputs and 4 audio
outputs

System controller Pantura 1244 LFO, fibre optic interface

SD - PCT 1244 LFO

VdS approval G 211073

Art-No.: 32410

75

7.1 Voice evacuation system sound detect

Speaker Matrix 100 V, 32 speaker lines

SD - PMT 32

VdS approval G 211073

Art-No.: 32411

Speaker Matrix for the activating, switching and monitoring of 100 V speakers or
speaker lines. 32 individual outputs (100 V) are grouped into 4 terminal blocks,
which could be connected seperately to amplifiers
Integrated audio matrix with 12 connections for paging stations,
4 audio inputs for external auxiliaries and 4 audio outputs for the
processing in the speaker matrix
Interface connection for the Fire Control Panels of the system
detect 3000 via 8 independent and freely programmable inputs

Technical data
Operation voltage

Input voltage LOW UDATA + - UDATA-
Input voltage HIGH UDATA + - UDATA-
Input voltage differentiell


Output voltage
[UDATA + - UDATA-], RL = 54 Ohm
Slew rate CL = 50 pF per wire to Common
RL = 54 Ohm (Data+ to Data-)
Bus load
Input current amplifier



Input current -7 V U IN + 12 V
Input current -60 V U IN + 60 V
Outpout current line





Measurement ground fault resistance
Power consumption with
unloaded interfaces

Mounting

Colour housing

Material

Dimensions (H x W x D)





Weight

18 to 36 V DC
7 to -0,2 V
0,2 V to 12 V
0 to 100 V
RMS/0 to
141 V Pk
Min. 1,5 V
0,2 to 2 s
Max. 0,5 UL
0,05 to 7 RMS
0,07 to 10 A Pk
-0,15 to 0,25 m
-6 to 6 mA
0,05 to 7 A
RMS/0,07 to
10 A Pk
0 bis 550 KOhm
Max. 21 W
19 - fitting
Silver grey
Metal
44,4 mm (1 HE) x
483 mm (19)
x 240 mm
Approx. 3,85 kg

Intelligent voice management for an optimal routing of the


corresponding audio signals
Internal flash memory (128 MB) for wave-files for different voice
recordings or alarm signals with a maximum duration of 9 minutes
Scaleable audio memory for voice messages and evacuation signals
Permanent monitoring of all audio and control paths, processors,
memories, paging stations, decentralized modules, active error
interface and the display for individual error messages
Control and management of up to 30 speaker Matrix SD - PMT 32
Management of up to 240 speaker lines, 256 paging zones and
120 power amplifiers per controller
Dynamic power management of all amplifier channels
Integrated real time clock for time and calendar functions and
system messages
Optional time synchronisation via DCF 77 or GPS signals
Built in master clock for management of different varying slave clocks
User friendly and high performance PC programming software with
integrated online-help for an easy programming of the system via
Ethernet interface
Password protected access rights via programming software P-Control
Remote access via LAN or ISDN
Integrated Ethernet-interfaces
Incl. USB or Parallel Interface for the connection of a printer
Factory provided serial number for addressing in the system

76

7.1 Voice evacuation system sound detect

Paging station with 31 buttons, freely configurable

SD - PPS 31

Art-No.: 32413
The paging station SD - PPS 31 consists of 31 freely configurable keys for the
activation/deactivation of speaker lines, zones, switching functions etc.. The keys
can be freely assigned and labelled and can be fully illuminated (red, yellow,
green) to signal the switching status. A change over mode enables the assignement of two seperate functions to each key. One monitored microphone and one
speaker are factory-provided for the paging station.
Keypad with 31 freely programmable, fully illuminated LED keys
(red, yellow, green)
Configuration of all display functions possible
Labeling of each key by removeable key cap and seperate labels
A change over mode enables the assignement of
two seperate functions to each key

Technical data
Operation voltage 9 to 36 V DC
Connection Connection cable
with D-Sub connector 15-poles
Frequency response
-3 to 0 dB
(100 Hz - 20 kHz)
Current consumption Full load at 9 V = max. 1,8 A;
full load at 36 V = 0,5 A
Power consumption Approx. 18 W
Colour housing Grey
Material Metal
Dimensions (H x W x D)
Approx. 60 mm x 203 mm x
205 mm
Weight Approx. 1,85 kg

Several key functions e.g. paging area pre selection, call button with or
without chime, delete key, direct call buttom, group key, control key,
alarm start, alarm interruption, play track, auxiliary input selection,
volume control, audio monitor, system

Reporting functions, priority switching, special functions and


programmable LED test
Including elegant microphone
Microphone amplifier with integrated limiter
Integrated loudspeaker for monitoring and control
Permanent monitoring of the acoustic microphone and the
paging station control and the data communication
Connection of the paging station to the system controller for the
microphone signal, voltage supply, data communication via P-DATA bus
Factory provided serial number for addressing in the system

Paging station with 47 buttons, freely configurable

SD - PPS 47

Art-No.: 32414
Freely configurable, incl. speaker

Pantura system desk station with 56 keys

SD - PPC 56

Art-No.: 32858

Paging station with 63 buttons, freely configurable

SD - PPS 63

Art-No.: 32415
Freely configurable, incl. speaker

77

7.1 Voice evacuation system sound detect

Bus Optocoupler input-module

SD - PDM 80

Art-No.: 32555
The bus optocoupler input module SD - PDM 80 comes with 8 freely configurable
optocoupler inputs which can be individually used for different controls (e.g. connection of the fire control panels detect 3004 and detect 3016)
8 freely configurable potential free inputs

Technical data
Operation voltage 2 to 36 V DC
Input voltage optocoupler HIGH 5 to 36 V DC
Input voltage optocoupler LOW 0 to 0,7 V DC
Current consumption optocoupler
input (Ue = 536 V) 6 mA
Current consumption Max. 20 mA
Connection Bus participant
Colour housing Black
Material ABS
Dimensions (H x W x D) Approx. 35 mm x 98 mm x 88 mm
Weight Approx. 130 g

Each optocoupler-input can be individually configurated as


voltage input or as input for a potential free contact
Wide input voltage range
All inputs are protected against reverse polarity by integrated
inverse-polarity protection

Bus Relay output module, 8 freely configurable relays

SD - PDM 08

Art-No.: 32556
The bus relay output module SD - PDM 08 provides 8 freely configurable relay
contacts for general control tasks
Each relay can be individually configured as closed (NO) or open dry
contact (NC)

Technical data
Operation voltage
18 to 36 V DC
Connenction
Bus participant
Relay switching current 6,5 A
Switching voltage relay
48 V
Current consumption
UB = 18 V, no load: 33 mA


UB = 18 V, all relays operated: 110 mA


UB = 36 V, no load: 35 mA

UB = 36 V, all relays operated: 65 mA
Colour housing
Black
Material
ABS
Dimensions (H x W x D) Approx. 35 mm x 98 mm x 88 mm
Weigth
Approx. 160 g

With common power inlet on UEXT each relay can be individually set
to normally open contact voltage output (NO) or normally closed
contact voltage output (NC)

Combined module, 3 inputs, 6 transistor outputs

SD - PDM 36 S

Art-No.: 32557
The combined module SD - PDM 36 S comes with 3 freely configurable inputs
and 6 freely configurable transistor outputs. It is a module for controlling six DC
consumers and for interrogation of three potential free contacts
Connection of external loads via switching outputs (Lx)

Technical data
Operation voltage

12 to 36 V DC
Connenction

Bus participant
Current consumption
Max. 30 mA
Current consumption
output driver
Open load = 24 mA,

Allowable full load = 2,1 A
Load current (per output)
350 mA
Supply voltage outputs
9 bis 25 V DC
Colour housing
Black
Material ABS
Dimensions (H x W x D)
Approx. 35 mm x 98 mm x 88 mm
Weight
Approx. 130 g

All switching outputs are short-circiut-proof against the positve and the
negative wire supply
Isolated voltage supply of the switching outputs and the bus supply
Input wiring is possible via potential free contacts or alternatively via
NPN-transistor output of an optocoupler

78

7.1 Voice evacuation system sound detect

Ceiling speaker, powder coated metal, one piece, shallow

SD - DL-E 06-165/T

Art-No.: 32392

Metal ceiling speaker, deep version, EN 54-24

SD - DL 06-165/T-EN54

Art-No.: 32888

Metal ceiling speaker, deep version

SD - DL 06-165/T

Art-No.: 32528

Ceiling speaker, ball proofed, 165 mm speaker,

SD - DL-FF 06-165/T BS 5839

Art-No.: 32394
Ball proofed, incl. fire dome, BS 5839

Metal ceiling speaker, ball proofed

SD - DL 10-200/T-EN54

Art-No.: 32889
Ball proofed, 200 mm speaker, EN 54-24

Ceiling speaker, powder coated metal

SD - DL 10-200/T

Art-No.: 32539
Ball proofed, 200 mm speaker, excl. fire dome

Ceiling speaker, 2 speaker

SD - DL-AB 06-200/T-EN54

Art-No.: 32890
AB-wiring, EN 54-24

Surface-mounted ceiling speaker

SD - DL-A 10-200/T-EN54

Art-No.: 32891
200 mm Chassis, EN 54-24

Surface-mounted cabinet speaker

SD - WA 06-165/T

Art-No.: 32397
MDF-wood housing

Surface-mounted cabinet speaker, EN 54-24

SD - WA 06-165/T-EN54

Art-No.: 32892
MDF-wood housing, EN 54-24

Surface-mounted cabinet speaker

SD - WA-EN 06-100/T

Art-No.: 32549
MDF-wood housing, 2 speaker, AB-wiring

Surface-mounted cabinet speaker

SD - WA AB 06-100/T-EN54

Art-No.: 32893
MDF-wood housing, 2 speaker, AB-wiring, EN 54-24

Sound Projector, EN 54-24

SD - DA-S 20-130/T-EN54

Art-No.: 32885

Horn speaker, 10 Watt, weatherproof

SD - DK10T

Art-No.: 32400

Horn speaker, 15 Watt, weatherproof, EN 54-24

SD - DK15/T-EN54

Art-No.: 32886

Horn speaker, 30 Watt, weatherproof, EN 54-24

SD - DK30/T-EN54

Art-No.: 32887

Sound column, weatherproof

SD - TS-C 10-300/T

Art-No.: 32403

Sound column, weatherproof, BS 5839

SD - TS-C 10-300/T BS 5839

Art-No.: 32405

Sound column, 8 full range speaker weatherproof

SD - TS-C 50-1000/T

Art-No.: 32404

Sound column, 8 full range speaker

SD - TS-C 50-1000/T BS 5839

Art-No.: 32406

79

7.1 Voice evacuation system sound detect

Power amplifier 120 Watt

SD - AMP 120

Art-No.: 32561
The Power amplifier SD - AMP 120 amplifies the audio signal coming from the
system controller (PCT) to a 100 V signal which is being routed by the Speaker
Matrix (PMT 32) to the according speaker lines

Technical data
Supply voltage
115 V/230 V AC, 50/60 Hz
Power consumption with
unloaded interfaces
400 W
Outputs
100 V and 8 Ohm; Speech: 100 V;

Line output: 1 V, 600 Ohm
Inputs
Line input: 1 V, 47 kOhm,

symmetric, asymmetric, balanced,

unbalanced
Distortion factor
Less than 1% at 1kHz, nominal power
Battery voltage
24 V DC (MAX 10 % deviation)
Rated load-carrying capacity 180 W / 120 W
Frequency response
50 ~20.000 Hz +3 dB
Colour housing
Black
Material Metal
Dimensions (H x W x D)
Ca. 88 mm (2 HE) x 483 mm (19) x

300 mm
Weight
Approx. 10,0 kg

Flexibility provided by symmetric and asymmetric inputs for each


amplifier channel (XLR, Cinch, Jack )
The amplifier comes with a 100 V- respectively an 8 Ohm output for
the connection of speakers and the Speaker Matrix PMT 32 (32411)
respectively.
Including 24 V adapter for the emergency supply
Including one potentiometer at the amplifier front for the levelling out of
the amplifier
Integrated remote control input for a remote activation of the amplifier
Shallow design (2 HE) and 19-fitting

Power amplifier 240 Watt

SD - AMP 240

Art-No.: 32562

Power amplifier 480 Watt

SD - AMP 480

Art-No.: 32563
XLR, Cinch, Jack

4-Channel-Power amplifier, 4 x 120 Watt

SD - AMP 4x120

Art-No.: 32564
The 4-Channel-Power-amplifier SD - AMP 4x120 comes with four independently
amplifier channels. Each channel amplifies the audio signal coming from the system controller (PCT) to a 100V signal which is being routed by the speaker matrix
(PMT 32) to the according speaker lines
Flexibility provided by symmetric and asymmetric inputs for each
amplifier channel (XLR, Cinch, Jack )

Technical data
Supply voltage
115 V/230 V AC, 50/60 Hz
Power consumption with
unloaded interfaces
1.100 W
Outputs
100 V and 8 Ohm; Speech: 100 V;

Line output: 1 V, 600 Ohm
Inputs
Line input: 1 V, 47 kOhm,

symmetric, asymmetric, balanced,


unbalanced
Distortion factor
Less than 1% at 1kHz,

nominal power
Battery voltage
24 V DC (MAX 10 % deviation)
Rated load-carrying capacity 4 x 180 W/120 W
Frequency response
50 ~20.000 Hz +3 dB
Colour housing
Black
Material Metal
Dimensions (H x W x D)
Approx.. 133 mm (3 HE) x 483 mm

(19) x 380 mm
Weight
Approx. 25,5 kg

The amplifier comes with a 100 V signal (70 V/100 V selectable)


respectively
an 8 Ohm-output for the connection of speakers and the
Speaker Matrix PMT 32 (Art.-No. 32411) respectively
Including 24 V adapter for the emergency supply
Including one potentiometer per amplifier channel at the front for the
levelling out of the amplifier
Integrated overload and short-circuit protection
Intergrated temperature controlled blower for a suitable cooling
Remote control input for remote turn on the integrated amplifier
Shallow design (3 HE) and 19-fitting

80

7.1 Voice evacuation system sound detect

Player with CD/MP3 and tuner module

SD - RAC 02 with CD/MP3 and tuner module

Player and recording module


Art-No.: 32565

SD - RAC 02 with CD/MP3 and MP3-Record/Player


Art-No.: 32566
With CD/MP3 and MP3-record/player module (DIGI)

Control speaker with programme selector

SD - KL-PW-677

Art-No.: 32567

Volume control uP, 6 Watt

SD - LS 6 RUP

Art-No.: 32568

Volume control uP, 12 Watt

SD - LS 12 RUP

Art-No.: 32569

Volume control uP, 50 Watt

SD - LS 50 RUP

Art-No.: 32570

Volume control uP, 100 Watt

SD - LS 100 RUP

Art-No.: 32571

Programme selector uP, 6 programmes

SD - PW 6 RUP

Art-No.: 32572

Volume control - Programme selector combination,

SD - LS-PW 06 RUP

Art-No.: 32573
6 Watt, 6 programmes

Volume control - Programme selector combination,

SD - LS-PW 12 RUP

Art-No.: 32574
12 Watt, 6 programmes

Microphone pre-amplifier, adjustable, SD - MI-VO


Art-No.: 32575
Including 18 V phantom power

Line pre-amplifier, adjustable

SD - TO-VO

Art-No.: 32576

Mixer pre-amplifier

SD - UP-MX 04

Art-No.: 32577

Pre-amplifier, 8 channels

SD - PRE-AMP 08

Art-No.: 32578

Uninterruptible DC-current supply

SD - SON 24V 12A S100A RACK

Art-No.: 32581
12 A charging current, 100 A leakance current

19 dummy plate 3 HE black

SD - 19 FP-3 HE SW

Art-No.: 32806

19 dummy plate 6 HE black

SD - 19 FP-6 HE SW

Art-No.: 32807

81

7.1 Voice evacuation system sound detect

19 ventilation plate 1 HE black

SD - 19 FLP-1 HE SW

Art-No.: 32808

Mains monitoring device 230/400V AC, 35 A

SD - NSF 230/400

Art-No.: 32803

24 V DC monitoring device, 100 A

SD - SF 24/14

Art-No.: 32804

Cable set for SD - PMT 32, link for speaker lines

SD - A-9089

Art-No.: 32869

Cable set SD - PCT for 1 paging station with LSA-Plus

SD - A-9200

Art-No.: 32870

Cable set SD - PCT for 1 paging station with loose wires

SD - A-9201

Art-No.: 32871
Accessories to SD - A-9200

Cable set SD - PCT on 2x Line, 2x P-DATA with LSA-Plus

SD - A-9202

Art-No.: 32872

Cable set SD - PCT on 1 x Line, loose wires

SD - A-9203

Art-No.: 32873

Cable set 2x AMP Out on PMT 32 AMP-In / SpAMP-In

SD - A-9204

Art-No.: 32874

Cable set SD - PCT on DCF, Slave clocks

SD - A-9205

Art-No.: 32875
Fault with LSA-Plus

Cable set SD - PCT on OPTO - inputs 1-8 with LSA-Plus

SD - A-9206

Art-No.: 32876

Cable set SD - PCT/ SD - PMT 32 on 24V DC (Power)

SD - A-9207

Art-No.: 32877
With loose wires

Cable set for SD - PMT 32, bridge for AMP / SpAMP

SD - A-9208

Art-No.: 32878

Cable set SD - PMT 32 on relay override with LSA-Plus

SD - A-9209

Art-No.: 32879

Cable set SD - PMT 32 on relay override loose wires

SD - A-9210

Art-No.: 32880
Accessory of SD - A-9209

Cable set P-DATA from SD - PCT to 4 x P-DATA

SD - A-9211

Art-No.: 32881

Cable set SD - PMT 32 on 8 speaker lines with LSA-Plus

SD - A-9213

Art-No.: 32882

82

8. Door holder systems

Door holder systems for


fire protection closures
Door holder system detectomat-Dictator with DIBT approval
(general technical approval institution)
In this chapter detectomat presents products, which are used as door looking systems for fire protection closures.
The special specifications of individual applications and detailed accessories are not considered in the program but can be
obtained via your responsible sales contact.

Features at a glance:
Approval for different types of Door Holder Systems
Combined know-how for project-work, approval, acceptance test
and testing of Door Holder Systems
Intelligent solutions for mechanical and electronical special applications
and special ambient conditions
DIBT approved corresponding to approval number Z-6.5-1976
Please find detailed technical information of all components next to your corresponding contact
at www.detectomat.com

Smoke detector
Power Supply
Release Button
Magnetic Clamp
Anchor Plate

83

8.1 Accessories for door holder systems

Power supply E450

Type E 450

Art-No.: 30411
Power supply for door holders with electronic stabilized output voltage 24 V at
450 mA output current

Technical data
Operation voltage
230 V AC +-10 %, 50 Hz
Output voltage
24 V DC +- 10 %
Output current
450 mA
Current consumption
100 mA
Protection class
IP 30
Colour housing
Silver
Material
Stainless steel
Dimensions (H x W x D)
117 mm x 82 mm x 51 mm
Weight
750 g
DIBT-number Z-6.5-1976
General remarks
Only suitable for the mounting in

dry rooms

Warms up during operation
please consider sufficient aeration

Electronic stabilized output voltage of 24 V provided by a 230 V AC


input voltage
Integrated electronic adjustment control for the compensation of
variability in the supply voltage
Integrated Status-LED for the display of the operation status
Primary side protected with fuse 0,1 A
Integrated circuitry against short circuit at the output side
Robust stainless steel gousing with cable entry at the bottom side

Power supply E800

Type E 800

Art-No.: 30412
Power supply for door holders with electronic stabilized output voltage 24 V at
800 mA output current

Technical data
Operation voltage
230 V AC +-10 %, 50 Hz
Output voltage
24 V DC +- 10 %
Output current
800 mA
Current consumption
200 mA
Protection class
IP 20
Colour housing
White
Material
Sheet steel
Dimensions (H x W x D)
160 mm x 105 mm x 55 mm
Weight
1,2 kg
DIBT-number Z-6.5-1976
General remarks
Only suitable for the mounting in

dry rooms

Warms up during operation
please consider sufficient aeration

Electronic stabilized output voltage of 24 V provided by a 230 V AC


input voltage
Integrated electronic adjustment control for the compensation of
variability in the supply voltage
Integrated Status-LED for the display of the operation status
Primary side protected with fuse 0,1 A
Integrated circuitry against short circuit at the output side
Robust stainless steel gousing with cable entry at the bottom side

84

8.1 Accessories for door holder systems

Optical smoke detector for door control systems

CT 3000 O, incl. DRB 3000

VdS approval G 203036

Art-No.: 32291

Optical smoke detector for conventional systems with an optical measurement


method for earliest fire detection and indication according to DIN EN 54-7
Including relay base DRB 3000 for 24 V for the triggering of power supplies of
door controls according to DIBT Z - 6.5 - 1976

Technical data
Operation voltage
9 to 33 V DC
Quiescent current
100 A
Alarm current
20 mA
Outputs
1 Relay swich over 30 V/1 A

for magnetic clamp
Sensitivity
< 0,15 dB/m
Ambient temperature
-10 C up to +60 C
Humidity
Max. 95 %
Air speed
< 20 m/s
Protection class
IP 40
Colour housing
White (similar to RAL 9003)
Material ABS
Dimensions (H x )
44 mm x 100 mm
Standards
EN 54-7
CE-CPD-number 0786-CPD-20042

Integrated professional smoke detection system with highest reliability


for a secure alarm verification with 16 fold measurement and
intelligent logics.
Intelligent analysis and disruption mode for the elimination of
false alarms
Periodic sensor tests of the smoke chamber
Alarm output for the triggering of a LED indicators
Multicolour-LED for alarm- (red) and fault (yellow)
Integrated locking system for the protection against removal and
tamper
Including white relays base with integrated relay board for the
triggering of door controls with 24 V via a potential free change-over
contact

Door control panel

TSZ 0400

Art-No.: 30410
Door control panel for the control of fire protection closures and doors







Technical data
Operation voltage
230 V AC
Output voltage
24 V
Output current
Max. 800 mA
Potential free relays
1 Relay swich over 30 V/1 A for

magnetic clamp
Outputs
800 mA
Frequency
50 Hz 10 %
Protection class
IP 42
Colour housing
RAL 9002 grey white
Material ABS
Dimensions (H x W x D)
185 mm x 233 mm x 93 mm
Weight
680 g
DIBT-number Z-6.5-1646

85

Current supply for the connected detectors and magnetic clamps


Alarm analysis and control
Integrated reset function
External load output for sirens and beacons
Up to 3 panels cascadable with control linkage
Status indication for alarm, fault and normal operation via LED
Connection of up to 10 detectors and 12 magnetic clamps
Suitable for applications in EX-zones

8.1 Accessories for door holder systems

Optical smoke detector for door control systems

CT 3000 O incl. SDB DIBT

VdS approval G 203036

Art-No.: 32255

Optical smoke detector with base for conventional systems with an optical
measurement method for ealiest fire detection and indication for the connection
to the door control panel TSZ 400

Technical data
Operation voltage
9 to 33 V DC
Quiescent current
100 A
Alarm current
20 mA
OC-outputs
Max. 50 mA for LED-indicator or

piezo buzzer
Sensitivity
< 0,15 dB/m
Ambient temperature
-10 C up to +60 C
Sensitivity
Max. 95 %
Air speed
< 20 m/s
Protection class
IP 40
Colour housing
White (similar to >RAL 9003)
Material ABS
Dimensions (H x )
4 mm x 100 mm
Standards
EN 54-7
CPD-number 0786-CPD-20042
DIBT-number Z-6.5-1646

Integrated professional smoke detection system with highest reliability


for a secure alarm verification with 16 fold measurement and
intelligent logics
Intelligent analysis and disruption mode for the elimination of
false alarms
Periodic sensor tests of the smoke chamber
Alarm output for the triggering of a LED indicators
Multicolour-LED for alarm- (red) and fault (yellow)
Integrated locking system for the protection against removal and
tamper
Delivery including protective cover for installation phase

Manual release switch aP for door controls

HT aP

Art-No.: 30417
Manual release switch for the manual activation of door controls in surface
mounting design
Robust housing suitable for the surface mounting
Red rocker switch with inscription Tr schlieen
Manual activation of the release switch gives way to a fire door

Technical data
Colour housing
Red rocker, white corpus
Material ABS
Dimensions (H x W x D)
63 mm x 63 mm x 37 mm
Weight
76 g

Manual release switch uP for door controls


HT uP
Art-No.: 30418
Manual release switch for the manual activation of door controls in surface
mounting design
Robust housing suitable for the surface mounting
Red rocker switch with inscription Tr schlieen
Manual activation of the release switch gives way to a fire door

Technical data
Colour housing
Red rocker, white corpus
Material ABS
Dimensions (H x W x D)
80 mm x 80 mm x 25 mm
Weight
93 g

86

8.1 Accessories for door holder systems

Magnet clamp, wall mounting, 600 N, DIBT


EM GD 50 F 26
Art-No.: 32508
Magnetic clamp for wall mounting for the application with
door control systems
Integrated spark turn off diode for the protection against overvoltage
Integrated reverse voltage protection
Robust housing with zinc coated surface

Technical data
Operation voltage
24 V DC 10 %
Alarm current
67 mA (1,6 W)
Holding force
600 N
Remanence
0N
Switch-on time
100 %
Protection class
IP 20
Material
Steel, zinc coated
Dimensions (H x W x D)
83 mm x 55 mm x 26 mm
Diameter
Magnet 50 mm
Weight
402 g
DIBT-number Z-6.5-1976

Magnetic clamp 700 N wall mounting 26 mm


Properties and technical data like Art.No. 32508, however:

Technical data
Holding force
Dimensions (H x W x D)
Diameter
Weight

700 N
93 mm x 65 mm x 26 mm
Magnet 60 mm
1,2 kg

Magnetic clamp 1450 N wall mounting 39 mm


EM GD 70 F 39
Art-No.: 32510
Properties and technical data like Art.No. 32508, however:

Technical data
Alarm current
Holding force
Diameter (H x W x D)
Diameter
Weight

EM GD 60 F 26
Art-No.: 30428

71 mA
1.450 N
103 mm x 75 mm x 39 mm
Magnet 70 mm
1,074 kg

87

8.1 Accessories for door holder systems

Magnetic clamp 700 N wall mounting 70 mm


EM GD 60 K 70
Art-No.: 30422
Magnetic clamp for wall mounting with plastic foot for the application with
door control systems

Technical data
Operation voltage
24 V DC 10 %
Alarm current
67 mA (1,6 W)
Holding force
700 N
Remanence
0N
Switch-on time
100 %
Protection class
IP 40
Material
Steel, black
Height
70 mm
Diameter
82 mm (Magnet 60 mm)
Weight
100 g
DIBT-number Z-6.5-1976

Magnetic clamp 700 N rotary head 175 mm


Integrated release button for the manual interruption


Robust plastic housing with hidden cable entry for a protected
connection
Integrated spark turn off diode for the protection in case of
overvoltage
Integrated reverse voltage protection

EM GD 60 S 175
Art-No.: 30423
Magnetic clamp for universal mounting onto walls, ceilings and floors for the
application in door control systems

Technical data
Operation voltage
24 V DC 10 %
Alarm current
67 mA (1,6 W)
Holding force
700 N
Remanence
0N
Switch-on time
100 %
Protection class
IP 40
Colour housing
Light grey
Material Steel
Dimensions (H x )
107 mm x 96 mm
Diameter
96 mm (Magnet 60 mm)
Weight
760 g
DIBT-number Z-6.5-1976

Magnetic clamp 700 N rotary head 325 mm, DIBT


EM GD 60 S 325
Properties and technical data like Art.No. 30423, however:

325 mm x 96 mm
770 g

Magnetic clamp 700 N rotary head 475 mm, DIBT

Length 325 mm, 90 pivoting, length in pivoted status 287 mm

EM GD 60 S 475
Art-No.: 30425
Properties and technical data like Art.No. 30423, however:

Technical data
Dimensions (H x )
Weight

General remarks: A magnetic clamp, which keeps a fire door open,



has to be activated by a manual release switch,

which is not hidden by an open door

Art-No.: 30424

Technical data
Dimensions (H x )
Weight

Rotary head for floor and ceiling mounting, with out change of the
electrical connections
Length 175 mm, 90 pivoting, length in pivoted status 137 mm
Robust plastic housing with hidden cable entry for a protected
connection
Integrated release button for manual interruption
Integrated spark turn off diode for the protection in case of
overvoltage
Integrated reverse voltage protection

407 mm x 96 mm
1,2 kg

Length 475 mm, 90 pivoting, ength in pivoted status 437 mm

88

8.1 Accessories for door holder systems

Magnetic clamp, floor mounting, 700 N, DIBT


EM GD 60 FB
Art-No.: 30434
Magnetic clamp 700 N floor mounting 60 mm
Design in solid aluminium cast housing and resistant against any
mechanical impact or foreign objects on the floor
Demands and foreign objects on the floor
Integrated spark turn off diode for the protection in case of
overvoltage
Integrated reverse voltage protection

Technical data
Operation voltage
24 V DC 10 %
Alarm current
67 mA (1,6 W)
Holding force
700 N
Remanence
0N
Switch-on time
100 %
Protection class
IP 40
Colour housing
Black
Material Aluminium
Dimensions (H x W x D)
100 mm x 165 mm x 107 mm
Diameter
3 x 9 mm

(Mounting holes for floor mounting)
Weight
1,9 kg
DIBT-number Z-6.5-1976

Magnetic clamp in plastic housing, 700 N, DIBT


EM GD 60 F 26 T
Art-No.: 30430
Magnetic clamp 700 N in plastic housing, 700 N
Integrated release button for a manual disruption
Robust plastic housing with hidden cable entry for a protected
connection
Integrated spark turn off diode for the protection in case of
overvoltage
Integrated reverse voltage protection

Technical data
Operation voltage
24 V DC 10 %
Alarm current
67 mA (1,6 W)
Holding force
700 N
Remanence
0N
Switch-on time
100 %
Protection class
IP 20
Colour housing
White
Material Plastic
Dimensions (H x W x D)
102 mm x 70 mm x 25 mm
Diameter
Magnet 60 mm
Weight
500 g
DIBT-number Z-6.5-1976

General remarks: The terminal clamp is located on the base plate of



the magnet

89

8.1 Accessories for door holder systems

Magnetic clamp Ex 1450 N wall mounting 43 mm


EM GD 70 Ex
Art-No.: 30436
Magnetic clamp for wall mounting in explosionproof design for the application
with door control
Including connection cable of 2 m
Integrated spark turn off diode for the protection in case of
overvoltage
Integrated reverse voltage protection

Technical data
Operation voltage
24 V DC 20 %
Alarm current
70 mA (1,7 W)
Holding force
1.450 N
Remanence
0N
Switch-on time
100 %
Protection class
IP 66
Colour housing
Zinc coated
Material Steel
Dimensions (H x W x D)
110 mm x 75 mm x 43 mm
Weight
1,26 kg
DIBT-number Z-6.5-1976
AREX-number ExII2GEExemIIT6

Anchor plate with rubber bearing

AP GD 50 G 16
Art-No.: 32511
Elastic connection piece for the adjustment of an angle up to 10
Elastic connection piece for the adjustment of an angle up to 10
Zinc coated anchor plate
General remarks: The anchor plate requires at minimum the

same diameter like the pole face of the magnet to

utilize its holding force

Technical data
Material
Dimensions (H x W x D)
Diameter
Weight

Steel, zinc coated


55 mm x 55 mm x 16 mm
54 mm (anchor plate)
197 g

Anchor plate with rubber bearing


Art-No.: 30437
Properties and technical data like Art.No. 32511, however:

Technical data
Dimensions (H x W x D)
Diameter
Weight

65 mm x 65 mm x 16 mm
64 mm (anchor plate)
280 g

Anchor plate with rubber bearing

AP GD 70 G 20
Art-No.: 32512
Properties and technical data like Art.No. 32511, however:

Technical data
Dimensions (H x W x D)
Diameter
Weight

AP GD 60 G 16

75 mm x 75 mm x 20 mm
74 mm (Anchor plate)
518 g

90

8.1 Accessories for door holder systems

Anchor plate with angle joint

AP GD 50 W 16

Art-No.: 30441
The anchor plate provides a magnetic contact between the magnetic clamp
and the fire door
Angle joint with a slewing range of up to max. 60 in both
directions
Zinc coated anchor plate
General remarks: The anchor plate requires at minimum the same

diameter like the pole face of the magnet to utilize

its holding force

Technical data
Material
Dimensions (H x W x D)
Diameter
Weight

Steel, black
60 mm x 60 mm x 51 mm
51 mm (Anchor plate)
184 g

Anchor plate with angle joint

AP GD 60 W 16

Art-No.: 30438
Properties and technical data like Art.No. 30441, however:

Technical data
Diameter
Weight

64 mm (Anchor plate)
230 g

Anchor plate with angle joint

AP GD 70 W 54

Art-No.: 32513
Properties and technical data like Art.No. 30441, however:

Technical data
Dimensions (H x W x D)
Diameter
Weight

60 mm x 60 mm x 54 mm
74 mm (Anchor plate)
395 g

Anchor plate with telescope damper

AP GD 60 T 80

Art-No.: 30439
Anchor plate with telescope damping for providing a magnetic contact between the magnetic clamp and a fire door
Suitable for the installation on heavy doors and gates, where an absorption of
the impact is necessary

Technical data
Holding force
100 N at 200 mm spring deflexion
Colour housing
Black
Material Steel
Diameter (H x )
80 mm x 82 mm
Weight
350 g

Fibre-glass reinforced black robust plastic housing for heavy


mechanical loads
Elastically supported connection piece with attenuation function
Flexible support of the anchor plate for an adjustment of an angle
up to 10
Zinc coated anchor plate

General remarks: The anchor plate requires at minimum the same



diameter like the pole face of the magnet to utilize

its holding force

91

8.1 Accessories for door holder systems

Set 330, Magnetic clamp 500 N and anchor plate

Set GD 50 330

Art-No.: 32505
Set 330 consisting of: magnetic clamp in plastic housing 500 N, 49,5 mm
and anchor plate with angle joint
Suitable for the application with door control and fire protection closures
Magnet:
Integrated release button for a manual disruption
Robust plastic housing

Technical data

Magnet
Operation voltage
24 V DC 15 %
Alarm current
67 mA (1,6 W)
Holding force
500 N
Remanence
0N
Switch-on time
100 %
Protection class
IP 20
Colour housing
White
Material Plastic
Dimensions (H x W x D)
94 mm x 60 mm x 24,5 mm
Diameter
49,5 mm
Weight
500 g

Anchor plate:
Elastic connection piece for the adjustment of an angle up to 10
Zinc coated anchor plate


Material
Dimensions (H x W x D)
Diameter
Weight

Set 331, Magnetic clamp 500 N and anchor plate

Set GD 50 331

Art-No.: 32506
Properties and technical data like Art.No. 32505, however:

Technical data


Material
Dimensions (H x W x D)
Weight

Anchor plate
Steel, black
55 mm x 55 mm x 50 mm
55 mm
184 g

Anchor plate
Steel, zinc coated
55 mm x 55 mm x 16 mm
197 g

Set 398, magnetic clamp 500 N and anchor plate

Set GD 50 398

Art-No.: 32507
Set 398 consisting of: magnetic clamp and anchor plate with rubber bearing
for the application with door control systems
Magnet:
Magnetic clamp with 150 mm connecting wire
Feedback signal contact for monitoring
Robust housing with zinc coated surface

Technical data

Magnet
Material
Dimensions (H x W x D)
Weight

Steel, zinc coated


55 mm x 55 mm x 25 mm
200 g

Anchor plate:
Elastic connection piece for the adjustment of an angle up to 10
Zinc coated anchor plate


Material
Dimensions (H x W x D)
Diameter
Weight

92

Anchor plate
Steel, zinc coated
55 mm x 55 mm x 16 mm
54 mm
197 g

8.1 Accessories for door holder systems

Floor mounting/wall mounting spacer



for magnetic clamps EM GD 50 + EM GD 60

BWA
Art-No.: 32509
Floor mounting/wall mounting spacer for an easy and fast mounting of the
magnetic clamps EM GD 50 F and EMG 60 F
Rotary head, pivoting range up to 180
Adjustable in height and length of up to 70 mm
Incl. 4 screws for the fixation of the magnetic clamps

Technical data
Colour housing
Material
Dimensions ()
Weight

White (RAL 9010)


Sheet steel
(Magnet 60 mm)
612 g

Label base for test plate


ET
Art-No.: 32691

Technical data

Label holder with four holes to apply the label decrease

Colour White
Material ABS
Dimensions (H x W x D)
65 mm x 120 mm x 2 mm
Weight
16 g

Sturdy plastic carrier material with four mounting holes


Recording space for label inspection (Art.-No.32692)

Approval tab

AE

Art-No.: 32692
Label describing acceptance of hold

Technical data
Colour
Material
Dimensions (H x W)

White with black printing


Adhesive foil
105 mm x 52 mm

Operation log book


Technical data
Colour White
Material Paper
Dimensions (H x W)
A5

Foil sticker with information to accept and repeat test according to


DIN 14677
Underside with protection film for adhesive surface

BB
Art-No.: 31021
Operating book to document the operating conditions and events during plant
operation
Paper-bound booklet
2 shots for inclusion in folders

93

9. RMA (Return Material Authorisation) conditions

1. The general terms and conditions of the detectomat GmbH are valid for

the handling of returned RMA deliveries.
2. Only material which is not older than five years can be accepted.

The serial number of the item is the proof for the age of item.
3.




The return of ordered materials which is not used will only be


accepted in original packing and only within 2 months after delivery
date. For this material a restocking charge of 15 % of the materials
invoice value but max. 200,- in specific cases, will be invoiced.
This is also valid for wrong deliveries which are not in the response
of detectomat.

4. To ensure a correct and fast handling, the following details have to be



provided with the return:

- RMA number which is provided by detectomat for each
individual shipment (The RMA number has to be requested
to detectomat before the shipment).

- Serial number of the product

- Software version of the product

- complete and clear description of the fault

Only if the above details are complete, then the return can be pro
cessed by detectomat and if necessary a replacement can be sent.

5.




Replacement parts will be selected with equivalent software and will


be provided by the replacement stock. In this case it can also be a
reconditioned and tested product. If an adequate replacement part is
not available, a proposal for an appropriate system part will be
suggested. The charges for the service is according to the fixed
values below:
Component
DLI card 2 Loop

90,00
110,00

Bitbus interface

40,00

Control board SC8 and SC4

50,00

MC card

10.






Individual assembly groups of panels and accessories and network


components can be replaced in advance in case of failure by equivalent products with same software version and same construction
(see above) from the replacement stock.The advanced replacement
comes with an invoice for the repair costs, freight costs and the
replacement material value (see Appendix 2). After successful repair
a credit note for the material value will be issued and the repaired
material will be put onto replacement stock (buyback).

If the receiving inspection of detectomat comes to the conclusion


that a repair or maintenance of the assembly group or part is not
economical, then detectomat can provide a quotation for a replacement shipment.

14.


It must be pointed out that technical suggestions from our support


and exchange recommendations can not be provided with guarantee
for success. Also for these recommended exchange the above terms
and conditions are valid.

40,00

Mains supply board


LCD display

110,00
50,00

Redundant processor
Loop tester

Subject to alterations, Ahrensburg, August 2012

150,00
90,00

Easy check

90,00

FCP 3004 and 3004


plus

6.


Products with a replacement value of < 200,- list price, - except


for individual assembly groups of panels -, can be replaced in case
of failure by new products or equivalent material from the replacement stock. These products are tested in regard of fault and the
disposal or the repair and stock in the replacement stock will be
done by detectomat.

13. Due to economical reasons there is no cleaning and new calibration



of automatic detectors possible. In these cases it is recommended

to exchange the devices against new ones.

90,00

XP95/S60 cards

9.




12.


150,00

DLI card 1 Loo

A warranty for the function of the system in combination with


consequential damages caused by the primary fault and the partly
exchange of system components can not be given. In case of a
replacement of parts, it is recommended to do a functional test of
the system for a complete and correct operation of the system.

11. Products, which are claimed in between the warranty period of the
general terms and conditions and which failure is caused by

detectomat, will be replaced free of charge by new products.

Charge

Motherboard 3004/3016

8.



300,00

Detector Type HD, CT, PL

15,00

PL - Module

19,00

The replacement material is available at the prices according to


Appendix 1. Against the general terms and conditions detectomat
grants a warranty of 1 year for the replacement parts beginning with
the date of replacement delivery.

7. For returned material which does not contain any failure we have to
invoice the charges according to the table under paragraphe 5 and

the material will be sent back as received.

94

10. Spare parts and discontinued articles 2012

Spare parts
31243

E-3004

ATPE part 3004 Display-/control board

472,00

31241

E-3004

CPE part 3004 Cursor Board

178,00

31244

E-3004

NTE part 3004 Power supply transformer

297,00

40004

E-3004

RS-232E part 3004 RS-23

166,00

31242

E-3004

FIBE part 3004 E-Interface

197,00

32626

CPABP 3004 / 3004

E-part 3004

245,00

32627

E-3004+ CP

E-part 3004plus Cursor board

188,00

32625

E-3004+ LCD

E-part 3004

210,00

32624

E-3004+ MC

E-part 3004plus MC card

355,00

32629

MBP 3004

E-part 3004

Assembly kit

215,00

32628

NT 3004 / 3004

E-part 3004

Power supply

32623

E-3004+ CPU 08

E-part 3004plus Main computer

1.166,00

31202

E-3016 AP

E-part 3016 Connection board

584,00

31206

E-3016 ATP

E-part 3016 Display-/control board

575,00

31207

E-3016 CP

E-part 3016 Cursor board

178,00

31210

E-3016 T

E-part 3016 Transformer

550,00

31204

E-3016 CPU

E-part 3016 Main computer

31201

E-BMZ SCHL

E-part BMZ lock

31200

E-BMZ SCH

E-part BMZ key 1

16,00

31250

E-BMZ LCD

E-part LC display

134,00

plus

plus

plus

plus

plus

plus

plus

Display and operation board


LC display

787,00

1.406,00
53,00

Discontinued articles
31011

A-ALI-3240

X1XP95-2-loop-interface (30040)

1.219,00

30074

A-ALI 3240

X2XP95-2-loop-interface redundant (3016)

1.406,00

31028

A-OM95XP95

Optical smoke detector

116,00

31030

A-WM95-55

XP95 heat detector 55C

103,00

31031

A-WM95-90

XP95 heat detector 90C

103,00

31033

A-OM-D

Discovery optical smoke detector

128,00

31034

A-WM-D

Discovery heat detector

109,00

31035

A-MM-D

Discovery multi measuring detector

138,00

31036

A-XP95 EM

XP95 Input module

113,00

31037

A-XP95 EM

VXP95 Input module delayed

131,00

31038

A-XP95 EAM

XP95 Input-/output module

178,00

31039

A-XP95 AM-2

XP95 Output module with 2 relays

141,00

31041

A-XP95 EM mini

XP95 Input module mini

109,00

31042

A-XP95 EM CT

XP95 Module for conventional detectors

178,00

31043

A-XP95 SSM

XP95 Sounder module

178,00

31044

A-XP95 ISO

XP95 Isolator

31078

A-XP95 HFM ALU R

XP95 Manual call point red FEUERWEHR

206,00

31079

A-XP95 HFM ALU B

XP95 Manual call point blue HAUSALARM

213,00

31096

A-XP RM

XP95 Reset module

31176

A-XP95 SO

XP95 Detector base

31178

A-XP95 SO-I

XP95 Detector base with isolator

16,00

31179

A-XP95 SO-R

XP95 Detector base with relays

63,00

31,00

50,00
8,00

All prices in euro

95

11. General terms and conditions detectomat GmbH


1 General Controlling Provisions
1. No terms and conditions other than our Terms and Conditions of Sale
contained here in shall apply unless expressly approved in writing by
us.Our Terms and Conditions of Sale shall also apply in the event we
make delivery to the customer without objection although aware of
the existence of terms and conditions of the customer that differ from
our Terms and Conditions of Sale.

6. The customer may offset amounts due to the customer only if the
corresponding counterclaims are unappealable or undisputed or
recognized by us. In addition, the customer may exercise the right to
withhold payment only in the case of counterclaims in connection with
the same transaction.

2. All agreements made between us and the customer in connection


with the execution of this agreement are contained here in in writing.
This agreement may not be altered, supplemented or amended unless
agreed to in writing.

4 Delivery Delayed Acceptance Delayed Delivery


1. Delivery dates are subject to timely receipt by us of all documentation
to be supplied by the customer, required permits and approvals,
including but not necessarily limited to plans and are also subject to
performance of other obligations by the customer. If these conditions
are not fulfilled in due time, delivery shall be delayed accordingly. This
shall not apply in the event of delays for which we are responsible.

3. Our Terms and Conditions of Sale shall apply to transactions with


businessmen (Unternehmer) in the sense of Section 14 German
Civil Code, legal entities and public institutions.
4. Our Terms and Conditions of Sale shall also apply to all present and
future commercial relations with the customer.

2. Our obligation to make delivery is contingent upon timely and proper


performance of the customers obligations. We reserve the right at our
option to consider failure to perform (Section 320 German Civil Code BGB and impairment of performance (Section 321 German Civil Code
- BGB) as events of default.

2 Acceptance of Orders
1. Our offers are subject to change. We reserve the right to make
reasonable technical changes or changes in design, colour and/or
weight.

3. We may make partial delivery if no undue convenience is caused to


the customer.

2. In the case of orders pursuant to Section 145 German Civil Code


(BGB), we may at our option accept such orders within 2 weeks of
receipt.

4. In the event delivery or shipment is delayed by the customer by more


than one month from the date of announcement to the effect that the
merchandise is ready for delivery or shipment, we may invoice the
customer for storage charges in the amount of 0.5% of the price of the
respective merchandise per month or any fraction thereof, in which
case such charges may not exceed a total of 5%. The parties to the
agreement may claim higher or lower storage costs if any difference
can be documented.

3. Unless specified otherwise in these Terms and Conditions of Sale or


in our written confirmation, the INCOTERMS shall apply in the version
effective as of the date of this agreement.
4. Delivery is contingent upon correct and timely delivery of necessary
materials or merchandise to us (Obtaining supplies oneself clause).
We will inform the customer without delay in the event of nonavailability and promptly refund any payment received.

5. In the event the customer delays acceptance or fails to perform other


obligations, we may at our option claim reimbursement for any related
damages sustained by us, including but not necessarily limited to
reimbursement for additional expenses, without prejudice to further
claims.

5. All rights to illustrations, drawings, calculations and other documents


shall remain our property. This shall also apply to any written materials
designated as confidential. The customer shall obtain our express
approval in writing before making any such materials available to
other parties.

6. In the event of a situation pursuant to Section 5 above, risk of loss or


damage shall pass to the customer upon the occurrence of any such
delay or default on the part of the latter.

3 Prices Terms of Payment


1. Unless specified otherwise in our written confirmation, our prices are
ex works (exw) and exclusive of packing which will be invoiced
separately.

7. All acts of God (e.g. mobilization, war, insurrection, strikes, lockout or


similar events) beyond our control shall release us from performance
of our contractual obligations for the duration of any such occurrences.
We will immediately inform the customer of our inability to perform
our obligations under the agreement and promptly refund to the
customer any corresponding payment received by us . In the event
the duration of such an occurrence exceeds a period of three months,
we may cancel the agreement.

2. We reserve the right to modify our prices accordingly in the event of


increases or decreases in costs, including but not necessarily limited
to increases or decreases due to wage agreements or changes in
the prices of materials. We will document any such changes at the
customers request.
3. In the event delivery is to be made more than four months from the
date of acceptance of the order or cannot be made earlier for reasons
for which the customer is exclusively responsible, we reserve the right
to invoice the appropriate price as of the date of delivery instead of the
original price agreed upon.

8. In the event delivery is delayed by us, our liability is limited to that


prescribed by law if the underlying purchase agreement specifies a
firm delivery date in the sense of Section 286 (2) 4 German Civil Code
(BGB) o Section 376 German Commercial Code (HGB) pertaining to
non-fulfillment. We are also liable as prescribed by law in the sense
that the customer may claim that it is no longer interested in further
performance due to a delay in delivery caused by us.

4. Our prices are exclusive of applicable value added tax (VAT). Applicable
value added tax will be included separately in the invoice on the billing
day.

9. We are also liable as prescribed by law for any delivery delay due to
breach of the agreement due to willful or gross negligence. We assume
responsibility for acts of negligence on the part of our representatives
or agents. In the event the delivery delay is not due to breach of the
agreement through willful negligence by us, our liability is limited to
claims for damage that normally could have been anticipated.

5. Unless specified otherwise in our written confirmation, the customer


shall pay the net purchase price (with no deductions) within 10 days of
receipt of the invoice, at which time the invoice shall become due and
payable. Legal remedies shall apply in the case of past due accounts.

96

11. General terms and conditions detectomat GmbH


10. We are also liable as prescribed by law in the event delivery is delayed
through breach of a material obligation under the agreement through
negligence. In such cases, however, liability is limited to claims for
damages normally could have been anticipated.
11. In addition, we are liable for a flatrate penalty for delayed delivery in
the amount of 0.5% of the price of the respective merchandise per
entire week, which penalty may, however, not exceed a total of 5%.
12. Any other legal rights and remedies the customer may have shall
remain in effect.

7. We are liable as prescribed by law in the event we commit a material


breach of the agreement. In such cases, however, our liability for
damagesis limited to claims for damages that normally could have
been anticipated.

5 Cancellation
1. The customer may cancel the agreement as allowed by law only in
the event of culpable default by us. However, in the case of defects
(Section 7 below), legal remedies shall apply.

8. We assume liability for injury to the life, body or health through


negligence on our part. This also applies to compulsory liability
pursuant to product liability legislation (Produkthaftungsgesetz).

2. The customer shall in the event of default by us inform us within a


reasonable period after being asked to do so by us whether it intends
to cancel the agreement due to the event of the default or whether it
insists upon delivery.

9. Any other form of liability not specified above is excluded.


10. Claims for defects must be reported within 12 months. In the event
the newly manufactured product is a structure or is on the basis of its
normal function used for a structure and has caused a defect in such
a structure, an exception will be made and the period for reporting
claims will be extended to 36 months. Our legal liability pursuant to
Sections 6 and 8 and in the case of willful deceit shall not be affected.

11. The period for reporting claims pursuant to Sections 478 and 479
German Civil Code (BGB) shall not be affected and shall extend for
a period of five years from the date of delivery of the defective item.
Recourse against us pursuant to Section 478 German Civil Code BGB
(recourse of customer)is only possible in the event the customer has
not made any agreement with its customer that goes beyond legal
liability for defects.

6 Transfer of Risk of Loss or Damage


1. Unless specified otherwise in our written confirmation, our prices are
understood to be ex works (exw).
2. We reserve the right to ship merchandise from locations other than
the place of delivery. At the request of the customer, we will have the
merchandise insured during transport, in which case the customer
shall bear the corresponding costs.
7 Claims for defects
1. Claims for defects may not be made in the event of insignificant
deviations from the agreed upon characteristics, insignificant
impairment of functionality, normal wear and tear or damage
resulting from improper or negligent treatment after risk of loss or
damage passes to the customer, excessive use, unsuitable operating
consumables, improper site preparation or unusual external factors not
provided for in the agreement or in the event of intermittent software
problems. In the event of improper modifications or maintenance by
the customer, we can assume no responsibility for such modifications
or maintenance or the ramifications thereof.

8 General Liability
1. Liability for damages other than that provided for in Section 7 is
excluded, regardless of the legal nature of the claim, including but
not necessarily limited to claims for damages due to negligence
in connection with the acceptance of the order, other breaches of
obligations or claims for damages to property pursuant to Section 823
German Civil Code (BGB).
2. The exclusion pursuant to Section 8.1 above also applies in the event
the customer claims reimbursement for needlessly incurred expenses
instead of damages.

2. The customers rights in the case of a defect are dependent upon


proper inspection and notification in compliance with Section 377
German Commercial Code (HGB). Notification of defects must be made
in writing. The customer shall bear the burden of proof in connection
with all such claims, including but not necessarily limited to proof of
the existence of the defect, the time of occurrence of the defect and
timely notification of the defect.

3. Insofar as liability for damages is excluded or limited, this shall also


apply to claims for damages against our employees, representatives
and agents.
9 Usage of software and firmware industrial property rights

3. In the event of notification of a defect, the customer may withhold


payment only in a reasonable amount with respect to the extent of the
defect. The customer may not refuse to accept delivery in the event of
insignificant defects.

1. The customer has the non-exclusive right to use the standard


software and firmware, with the agreed performance characteristics,
in an unmodified form and within the agreed devices. The customer
may make a backup copy of the standard software without the need
for an express agreement.

4. In the event of a defect, we may at our option repair the defective


merchandise or deliver new merchandise free of defects to replace
the original merchandise.

2. The goods supplied by us are subject to industrial property rights (e.g.


patent rights, trademark rights and ownership rights). The customer
shall, in the case of applying or using the goods, respect our industrial
property rights, as well as the industrial property rights of third parties.

5. In the event the repair is unsuccessful, the customer may at its option
cancel the agreement or request a reduction in price. In the event of
negligible defaults, including but not necessarily limited to negligible
defects, the customer may not cancel the agreement.

10 Retention of Title
1. We retain title to the merchandise until all payments from business
with thecustomer are made in full. In the event the customer has
an account with us, our reservation of title also applies to any
acknowledged outstanding balance, and the same applies in the event
a balance is not acknowledged and a balance is made for cause, for
example, in the event of bankruptcy or insolvency by the customer.

6. We are liable as prescribed by law for claims made by the customer


based on willful or gross negligence on the part of our representatives
or agents. In cases other than intentional breach of the agreement,
our liability for damages is limited to claims for damages that normally
could have been anticipated.

97

11. General terms and conditions detectomat GmbH


2. In the event of breach of this agreement by the customer, including
but not necessarily limited to failure to make payment when
due, we may retake possession of the merchandise sold without
canceling the agreement beforehand. The customer hereby
agrees to allow us to enter its business premises during normal
business hours to retake possession of the items in question in
any such situation. After retaking possession of the items sold,
we may dispose of them and credit the proceeds, less appropriate
disposal costs, to the outstanding balance due us.

10. We agree to release securities in our favor at the request of the


customer in the event the realizable value of sure securities exceeds
the value of the secured amounts due by more than 10%. We may
determine at our own discretion which securities to release.

3. The customer shall take proper care of the merchandise and shall have the
merchandise adequately insured at new value at its own expense against
fire damage, flood damage and theft. In the event maintenance and
inspections are necessary, the customer shall have such work carried
out on a timely basis at its own expense.

11 Support and Assistance


1. If, in addition to supplying merchandise, we also provide the customer
with support and/or assistance with the installation/start-up of the
merchandise, the limitation of liability described in Sections 7 and 8
shall apply accordingly.

4. In the event of attachment or any other such proceeding initiated by


third parties, the customer shall inform us in writing so that we can
take actionpursuant to Section 771 Code of Civil Procedure (ZPO). In
the event any such third party is not in a position to reimburse us for
legal and extralegal expenses resulting from such an action pursuant
to Section 771 Code of Civil Procedure (ZPO), the customer shall bear
any such expenses.

12 Venue Place of Delivery Governing Law


1. This agreement shall be subject to the exclusive jurisdiction of the courts
of our principal place of business in the event the customer is a
businessman in the sense of Section 14 German Civil Code (BGB), a
legal entity or a public institution. We may, however, file suit against
the customer before the courts of the customers principal place of
business.

5. The customer may resell the merchandise in the normal course of its
business. However, the customer shall assign the full invoiced amount
(including VAT) due from its customer or other parties from the sale
to the outstanding balance due to us; and this condition shall apply
whether or not the merchandise purchased from us is sold without
or after processing. The customer shall remain authorized to collect
the amount due after assignment to us. Our right to make collection
ourselves remains unaffected. However, we agree to refrain from
making collection as long as the customer applies the proceeds from
the sale to meet its payment obligations toward us, is not in arrears
and, in particular, no insolvency proceeds have been opened against
the customer and the customer has not suspended payment. In any
such event, we may demand that the customer make known to us
the assigned re-ceivables and the corresponding debtors, provide all
information re-quired for collection, make available the corresponding
documents and inform the debtors (third parties) of the assignment.

2. In the event the customer is a businessman in the sense of Section


14 German Civil Code (BGB), a legal entity or a public institution and
nothing is specified to the contrary in our written confirmation, our
principal place of business shall be the place of delivery.
3. This agreement shall be governed by the laws of the Federal Republic
of Germany. Application of the United Nations Convention on Contracts
for the International Sale of Goods (1980) CISG is expressly
excluded.
4. In the event of differences of opinion arising from these Terms and
Conditions of Sale or in the case of doubt, the original Germanlanguage version and it alone shall be legal and binding.

6. The processing or modification by the customer of the merchandise


is in all cases performed for us. In the event the merchandise is
processed with other objects that are not our property, we acquire
partial ownership of the object in proportion to the value of the
merchandise (total invoice amount, including VAT) as compared with
that of the other processed objects at the time of the processing. In
addition, the same reservation of title that applies for the merchandise
also applies for the object that results from the processing.

Technical modification
Due to continuous development of our products, together with altering
manufacturing methods, the description and data provided are for information onlx and subject to changes without notice.
Information supplied by the catalogue
We accept no responsibility for the accurancy of the information given in
the catalogue. Our prices are exclusive of applicable value addes tax (VAT).
Applicable cale added tax will be included separately in the invoice on the
billing day.

7. In the event the merchandise is inextricably combined with objects


that are not our property, we acquire partial ownership of the new
object in proportion to the value of the merchandise (total invoice
amount, including VAT) as compared with that of the other combined
objects at the time they are combined. In the event the combination
is such that the property of the customer is to be considered the main
product, it is agreed that the customer shall transfer proportionate
ownership rights to us. The customer shall then hold the resultant sole
or partial property for us.

Updates you will find at www.detectomat.com


General terms of conditions detectomat GmbH,
Revised: Ahrensburg, August 2012

8. The customer shall also assign to us those amounts due from third
parties as a result of the attachment of the merchandise to real estate
property to secure amounts due to us.
9. In the event the reservation of title or assignment is not effective in
the jurisdiction in which the object is located, it is agreed that the
security corresponding to reservation of title or assignment in that
jurisdiction shall obtain. If the creation of this security requires actions
on the part of the customer, the latter shall at our request take any and
all measures required to create and maintain such rights at its own
expense.

98

99

detectomat GmbH
An der Strusbek 5 22926 Ahrensburg Germany

Tel.: +49 (0) 4102 - 2114 - 60


Fax: +49 (0) 4102 - 2114 - 670

E-Mail:
Web:

info@detectomat.com
www.detectomat.com

You might also like