PURPOSE:
APPLICATIONS:
METHODS:
Volatility
GASOLINE, DIESEL, JET,
OTHER COMMERCIAL FUELS
REFINERY PROCESS STREAMS
SHORT-CUT DISTILLATES
CONTAMINATED FUELS
TRANSMIX
ADVANTAGES:
Time saving 10 min
turnaround
Highly repeatable
physical distillation
One-button test
initiation
Pass/Fail mode for
fast product quality
evaluation
High sensitivity to fuel
contamination
Portable design
Robust operation,
low maintenance cost
AUTOMATED
Micro
Distillation Analyzer
MOBILE LABORATORIES
PIPELINE, TERMINALS
FUEL BLENDING
REFINERY IN-PLANT TESTING
RESEARCH CENTERS
PMD 100 & 110
A
utomatic MicroDist Analyzer from ISL is
an innovative instrument employing leading
research and the most advanced technology.
In minutes, the PMD provides reliable distillation
characteristics in correlation to ASTM D 86.
Unique design allows true push-of-a-
button operation making the unit exceptionally
user-friendly for untrained staff with limited time
or exposure to laboratory equipment. Compact,
rugged and fully independent, the instrument
enables installation in mobile labs or on-site
locations ideal to workow reducing response time
and signicantly increasing test productivity.
Employing the most reliable principle -
physical distillation of liquid sample - the PMD
MicroDist increases operation efciency when
used for fuel screening at logistical points, for
rening process streams quality monitoring and
fuel blending.
ASTM D 7345
CORRELATES TO THE FOLLOWING
METHODS AND CORRESPONDING
ANALOGS:
ASTM D 86
ISO 3405
IP 123
YOUR LOCAL REPRESENTATIVE:
Copyright 2007 PAC L.P.
|
PMD110 ver 1.0
|
Printed in USA 0306
FOR ADDITIONAL INFORMATION
USA
8824 Fallbrook Drive , Houston, Texas, 77090
Phone: 800.444.TEST [281.9400.1803] | Fax: 281.580.0719
sales@paclp.com | service-lab@paclp.com
France
BP 70285 - VERSON - 14653 CARPIQUET Cedex
+33 (0) 231 264 300 | fax +33 (0) 231 266 293
sales@paclp.com.fr | service@paclp.fr
Germany
Badstrasse 3-5, P.O. Box 1241 D-97912 Lauda-Knigshofen
+49 9343.6400 | fax +49 9343.640.101
sales@paclp.com.de | service@paclp.de
Singapore
10, Eunos Road 8, #12-06 Singapore Post Centre 408600
+65 6742 8453 | fax +65 6742 8759
sales@paclp.com.sg | service@paclp.com.sg
QUICK DISTILLATION, HIGH THROUGHPUT
Immediately start testing without concern over ask and
measurement device adjustments or heater power settings
Results in under 10 minutes
Locally display and store results; send data to printer, PC
software or LIMS network
Perform up to 5 tests per hour, beginning a new test
immediately after one has completedno apparatus
conditioning or cleaning necessary
INTELLIGENT ANALYSIS
No pre-testing or programming required sample type is
automatically recognized and appropriate heating method
and data treatment is applied
Quick results validation using exible, user-dened criteria
and automatic pass/fail notication
Enhanced sensitivity to contamination levels is ideal for
fuel screening
Built-in, sophisticated, quality and calibration features
assure complete results traceability
Patented design eliminates cooling unit, receiver and
volume measurement; distillate condenses into waste bottle
Continual self-monitoring and multiple safety features
ensure CE compliant operation
DEPENDABLE OPERATION AND SUPPORT
Quality construction and reliable operation backed by a
limited parts and service warranty
Expert sales and service from PACs worldwide network of
factory trained authorized representatives
INJECT SAMPLE LOAD FLASK PRESS START GET RESULTS
SPECIFICATIONS
Ordering Information Model PMD 110 MicroDist Portable Analyzer
Model PMD 100 MicroDist Analyzer
Standard Test Method Correlation to ASTM D 86, ISO 3405, IP 123 and analogs
Operation Principle Physical distillation of liquid samplethe most reliable
principal to determine distillation characteristics of petroleum
products. Measures vapor & liquid temperatures by
non-inertial, low mass thermocouples, further monitoring
pressure in the distillation ask as the sample gradually
distills under atmospheric pressure. Collected data is
processed and converted to ASTM D 86-compliant format.
Sample Size 10 ml
Performance
Test Time <10 minutes for complete run
Temperature Range 0 to 400C (32 to 752F)
Sensitivity 0.1C (0.1F)
Operation
User Interface Graphic LCD display; solvent-proof alphanumeric keypad
with dedicated function keys
Calibration Automatic calibration routine with programmable frequency;
printed reports
Heating System Low mass, self-positioning low voltage heating element
(125W); fast air cooling at end of test
Measurements
Temperature Non-inertial, low mass thermocouples protected by rigid
metal thermowell for reliable operation
Pressure Built-in gauges: differential (in-ask pressure) & barometric
Volume Percent recovered or evaporated calculated against recorded
pressure variation in the ask during distillation run
Results Management
Documentation Complete method-compliant report, or custom selected
distillation points; on local screen; on external printer;
data export to LIMS or external PC via built-in RS-232 or
RS-485 interfaces
Results instantaneously reported in C or F;
Automatic barometric correction
Data Memory Locally retains 45 results;
Product Memory Up to 40 product names with associated specications
Specications Memory Up to 80 customized product specications (i.e. typical
temperature versus volume, or volume versus temperature)
PC Software Database management, results comparison, run control,
exible LIMS protocols and other functions enabled when
connected to optional Windows based PC software
Physical
Ambient Conditions Operation: 10 to 30C (50 to 86F)
Storage: -20 to 40C (-4 to 104F)
Electrical Requirements 100240 VAC (auto switching), 50/60 Hz, 200 watt;
Optional car battery +12 DC adapter available
Dimensions 250mm W x 400mm D x 330 mm H (9.8 x 15.75 x 13 in)
Weight 14 kg (37 pounds)
Due to continuing product development, specications subject to change at any
time without notice.
UNIQUE PHYSICAL DISTILLATION
FOR FAST, ON-SITE ANALYSIS
P
M
D

1
0
0

&

1
1