You are on page 1of 2

LOAD CALCULATIONS

:
:
:
:

Job No.
Project
Clint
Description

Building Type

Length (o/o)
Width (o/o)
Width module
Bay spacing
Clear eave height
Max. eave height
Roof slope ()

=
=
=
=
=
=
=

82.00 m
40.50 m

Wt. of sheet & purline


Dead Load (DL)

=
=

15.00 Kg/m
1.05 KN/m

Collateral Load on Rafter

=
=

0.00 Kg/m
0.00 KN/m

Live load/unit area, roof


Live Load (LL)

=
=

75.00 Kg/m
5.25 KN/m

Basic wind speed (Vb)


Design wind speed (Vz)
where,

=
39 m/s
= Vbxk1xk2xk3

7.00
7.00
8.00
5.71

Rev. No.
Date
Designed by
Checked by

LOADS APPLIED ON THE MAIN FRAME-1

:
:
:
:

R0
26/08/2014

m
m
m

DEAD LOAD (DL)

COLLATERAL LOAD
Other Collateral Load

=
=

0.00 Kg/m
0.00 KN/m

LIVE LOAD (LL)

WIND LOAD (WL)

k1 = probability factor (risk coefficient)


=
1
k2 = terrain, height and structure size factor
=
0.93
k3 = topography factor
=
1
Vz =
36.27 m/s
Design wind pressure (pz)

=
pz =

Terrain Category
2

Class
B

0.6xVz
0.789 KN/m
PRESURE COEFFICIENTS:~

Encloser condition of the building = Enclosed


Internal pressure coeff.(Cpi) =
0.20
h/w =
0.20
= h/w<=1/2
l/w =
2.02
= 3/2<=l/w<4
External pressure coeff.(Cpe) :
Wind Angle
()
0 degree
90 degree

Table 4
Coeff. For Wall
Left
Right
0.70
-0.25
-0.50
-0.50

Table 5
Coeff. For Roof
Left
Right
-0.9350
-0.40
-0.80
-0.80

WIND LOAD DIAGRAMS:~


Wind Across the Ridge (With -Ve Cpi)
-0.74
-4.06 KN/m
-0.20

KN/m
4.97
0.90

Wind Across the Ridge (With +Ve Cpi)


-1.14
-6.271 KN/m
-0.60

-1.11KN/m

KN/m
-0.28
-0.05

KN/m
2.76
0.50

Wind Parallel to Ridge(With +Ve Cpi)


-1.00
-5.53 KN/m
-1.00

KN/m
-2.49
-0.45

-5.53 KN/m

KN/m
-3.87
-0.70

KN/m
-3.87
-0.70

Wind Parallel to Ridge(With -Ve Cpi)


-0.60
-3.32 KN/m
-0.60

KN/m
-1.66
-0.30

KN/m
-3.32

-3.32 KN/m

KN/m
0.00
-0.30
Note:
1) Values within the circles are the UDL

2) -Ve value means, load applied


away from structure.