Multi-Service Fiber Optical Multiplexer

LIGHTSMART -PE150
Users Manual









TM
i
Table of Contents
Chapter I Introduction .................................................................................... 1
1-1 PRODUCT DESCRIPTION ..................................................................................................1
1-2 APPLICATION DIAGRAM..................................................................................................1
1-3 PRODUCT FEATURES........................................................................................................2
1-4 TECHNICAL SPECIFICATIONS...........................................................................................3
1-5 ORDER INFORMATION .....................................................................................................5
Chapter II Installation Guide ......................................................................... 8
2-1 UNPACKING.....................................................................................................................8
2-2 SITE REQUIREMENT ........................................................................................................8
2-3 SITE SELECTION..............................................................................................................9
2-4 DC ELECTRICAL OUTLET CONNECTION..........................................................................9
2-5 LASER SAFETY ................................................................................................................9
Chapter III Panel Description....................................................................... 10
3-1 FRONT PANEL................................................................................................................10
3-2 REAR PANEL..................................................................................................................11
Chapter IV VT-100 Operating Instructions ................................................ 13
4-1 BOOTING AND LOGIN SCREEN.......................................................................................14
4-2 MAIN MENU..................................................................................................................15
4-3 SYSTEM CONFIGURATION..............................................................................................16
4-3-1 System Information Configuration.......................................................................... 17
4-3-2 Device Networking Configuration.......................................................................... 18
4-3-3 User Account Management..................................................................................... 19
4-3-4 SNMP Agent Configuration .................................................................................... 21
4-3-5 Software Upgrade Configuration............................................................................ 22
4-3-6 Software Upgrade and Reboot Operation .............................................................. 24
4-3-7 Network Time Synchronization ............................................................................... 27
4-3-8 Scheduling Job Management .................................................................................. 29
4-3-9 Networking Service Management ........................................................................... 31
4-3-10 Network TroubleShooting Operation.................................................................... 32
4-3-11 LCD Login Configuration..................................................................................... 34
4-3-12 Event Management ............................................................................................... 35
4-3-13 System Profile Management.................................................................................. 38
4-4 TRIBUTARY SLOT INTERFACE SELECTION......................................................................40
4-4-1 E1 Interface Configuration..................................................................................... 41
4-4-2 V.35 Interface Configuration................................................................................... 43
4-4-3 Ethernet Interface Configuration............................................................................ 45
4-4-4 Tributary TSA Configuration .................................................................................. 46
ii

4-5 OPTICAL INTERFACE PARAMETERS CONFIGURATION.................................................... 53
4-6 PERFORMANCE MANAGEMENT THRESHOLD CONFIGURATION...................................... 55
4-6-1 E1 Interface Threshold Setting............................................................................... 56
4-6-2 Aggregate Interface Threshold Setting................................................................... 58
4-7 FAULT MANAGEMENT PARAMETERS CONFIGURATION.................................................. 59
4-7-1 Alarm Severity Config ............................................................................................ 60
4-7-2 Power Failure Monitoring Parameter Config ....................................................... 61
4-8 EXTERNAL CLOCK CONFIGURATION AND MONITORING................................................ 62
4-8-1 External Clock Config............................................................................................ 63
4-8-2 External Clock Monitoring..................................................................................... 64
4-9 OE PROTECTION SWITCHING........................................................................................ 65
4-10 EQUIPMENT STATUS MONITORING.............................................................................. 67
4-11 PERFORMANCE MONITORING...................................................................................... 68
4-12 PATH ALARM MONITORING......................................................................................... 70
4-13 LOOPBACK/V.54 TESTING .......................................................................................... 71
4-14 PRBS TEST ................................................................................................................ 75
4-15 EVENT BROWSING...................................................................................................... 78
Chapter V LCD Operating Instructions ...................................................... 79
5-1 LCD MENU TREE......................................................................................................... 80
Appendix ............................................................................................................ 83
A-1 CARFT PORT INTERFACE .............................................................................................. 83
A-2 RACK MOUNT INSTALLATION GUIDE........................................................................... 84








1
Chapter I Introduction
1-1 Product Description
The LightSmart-PE150 is a powerful optical multiplexer which can
aggregate three types of service into a pair of fiber. Any combination of
four kinds (4*E1, 4*V.35, 1*V.35, 1*10/100M Ethernet) of tributary card is
allowed to plug-in the system and its maximum capacity is 16 channel E1. It
supports the 1+1 hot-swappable optical protection. The LightSmart-PE150
can be managed through SNMP, VT100 craft port or LCD/menu keys. It
also supports orderwire function for maintenance purpose. It is 1U, 19 rack
mountable or desktop type model.



1-2 Application Diagram
















Router
LightSmart-PE150 LightSmart-PE150
2
1-3 Product Features
Channel Capacity 4, 8, 12, 16 E1 ( or datacom service)
Tributary card type E1 interface ( 75ohms or 120ohms)
Datacom interface (V.35/ RS-530/ X.21)
10/100Base-T Ethernet bridge port.
Optical module Auto Laser shutdown, hot swappable 1+1 protection
Alarm relay contact major and minor alarms
(audible and visible alarm output )
Support SNMP function, TFTP remote software upgradeable
Performance monitor E1 HDB3 CV, CRC, ES, SES.
Configurations can be backup to nonvolatile memory.
Provides the optical line local loopback and remote loopback function.
Low speed (E1, datacom) Local and remote loopback function
Built in PRBS pettern test for fault isolation and diagnostic purpose.
Management interface LCD / keys button, VT100 (DB9),
RJ 45 (for SNMP)
External clock (Optional) E1 external TTL clock or PCM data Input
through RJ 45 connector
OE module: Class 1 Laser product. Safety Standard IEC 825 compliant








3
1-4 Technical Specifications
Optical Interface
Optical Source MLM 1310/1550nm
Wavelength 1310/1550 50nm
System Gain 19, 30dB
Fiber connector types SC,FC,ST type
Bi-directional Fiber Optical Module (Option)

E1 module
Channel Capacity 4/8/12/16 channels
Bit Rate 2.048Mbps 50ppm
Line Code HDB3 / AMI
Frame Format Framed or Unframed
Electrical Interface Compliant with international standards ITU-T G.703
J itter Tolerance Compliant with ITU-T G.823
J itter Transfer Compliant with ITU-T G.742, G.823
Line impedance 120 DB25 Wire Wrap,RJ 45' or 75 BNC'
Surge protection (optional): Compliance with (or better than) IEC
1000-4-5 class 2 or FCC part 68

Datacom module
Datacom module supports one channel(V35U1) or four channels(V35U) on
each card'
Card type V.35, RS-530, X.21,
Data rate n*64K, n=1~32 (64~2048kb/s)
Clock mode Internal, DTE, Recovery.
Control signal CTS follows RTS, DSR always ON except at test loop
mode, DCD always ON except at fiber loss of signal condition.
Loop-back local loop back, remote loop back, V.54
Connector HD-68 (SCSI- ) Female with optional cables
HD-68 to 4*V35(M34 female) cable
HD-68 to 4*RS530(DB25 female) cable
HD-68 to 4*X.21(DB15 female) cable

4

10/100M Ethernet module
Compliance IEEE 802.3, 802.3u
Configuration modes 10/100M, full/half-duplex, auto-negotiation and
auto MDI/MDIX.
Maximum frame length 1536 byte tolerance of padded-frame in IEEE
802.1Q
Frame buffer 329 frames
MAC Table 1024-address LAN table.
WAN speed mapped into 4*E1, its maximum payload bit rate is 7.68M
Surge protection: IEC61000-4-5 class 2 or FCC part 68

Dimension
W * D * H 285 x 440 x 44.5 mm

Power Supply
AC 90, 240 V (47Hz, 63Hz)
DC -36, -72 V
Power consumption 20W maximum

Physical Specifications
Alarm contact 4 relay contacts (DB-9 connector) --Reference Page82(A-1)
Order wire Ear phone jack
Operate condition 0, 60, , 5%, 95% without condensing
EMI Comply with CISPR 22 class A (EN55022), FCC part 15 class A
subpart B.
MTBF 48,000 hours minimum







5
1-5 Order Information
Classification Item
Single Optical Link
Dual Optical Link (1+1 auto protection)
Single Hot Swap Optical Link
Optical Link Type
Dual Hot Swap Optical Link (1+1 auto protection)
1310nm Multi-Mode Laser Module
1310nm Single-Mode Laser Module, 30Km
1310nm Single-Mode Laser Module, 50Km
1310nm Single-Mode Laser Module, 70Km
1310nm Single-Mode Laser Module, 90Km
1550nm Single-Mode DFB Laser Module, 100Km
Laser Module Type
Bi-directional Fiber Optical Module (Make call us)
FC/PC Type Laser Module Connector
SC Type Laser Module Connector
Laser Module
Connector Type
ST Type Laser Module Connector
Single AC Power Module
Dual AC power Module
Single DC Power Module
Dual DC Power Module
Power Module Type
One AC and One DC Power Module
USA (1.8 M)
Europe
England
Power Cord
Australia
4E1 120 Ohm Balanced, Wire Wrap Adapter
4E1 120 Ohm Balanced, Wire Wrap Adapter with surge
protection
4E1 120 Ohm Balanced, Twist Pair Adapter Cable
4E1 120 Ohm Balanced, Twist Pair Adapter Cable with
surge protection
4E1 120 Ohm Balanced, RJ -45 Adapter Cable
4E1 120 Ohm Balanced, RJ -45 Adapter Cable with surge
protection
4E1 75 Ohm Un-Balanced, BNC Adapter Box
E1 Card and Adaptor
4E1 75 Ohm Un-Balanced, BNC Adapter Box with surge
protection
Ethernet Card 10/100 Fast Ethernet
4V35 Card 4xV35
1V35 Card Single V35
6
With External clock
External clock
Without External clock
8E1+V35
8E1
4E1+V35
Fix modeBNC ,
V35 Connecter on Mechanic
4E1

LightSmart-PE150 support 5 type of chassis for the different application as
following:
(a) Standard Type Rear View







(b) 4E1 fix mode BNC Rear View
4E1 BNC connecter(for 75 ohms mode) and any kind of the above cards is
allowed to plug into tributary slot 4. (TB4)








(c) 8E1 fix mode BNC Rear Rear View
8E1 BNC connecter(for 75 ohms mode) and any kind of the above cards is
allowed to plug into tributary slot 4. (TB4)







TB1
TB1 TB2
7

(d) 4E1 fix mode BNC and V35 Connecter on Mechanic Rear View
4E1 BNC connecter and V35 connecter on mechanic, and any kind of the above
cards is allowed to plug into tributary slot 4. (TB4)










(e) 8E1 fix mode BNC and V35 Connecter on Mechanic Rear View
8E1 BNC connecter and V35 connecter on mechanic, and any kind of the above
cards is allowed to plug into tributary slot 4. (TB4)









Front view of RJ45 at the rear of LightSmart-PE150












Note:
The DIP switch in items (b) (c) (d) (e) is only for the mode selection of channel 1.
For example, they should be all switched to down for the 120 ohms (balance)
mode and all up for the 75 ohms (unbalance).
TB1 TB2
TB1
Pin 1: RX_Ring1
Pin 2: Rx_Tip1 (input to the E1 card)

Pin 4: TX_Ring1
Pin 5: TX_Tip1 (output from E1 card)
8
Chapter II Installation Guide
This chapter provides the information needed to install
LightSmart-PE150. It is important to follow the installation instruction to
ensure normal operation of the system and to prevent damages due to
human error.


Only trained and qualified personnel should be allowed to install or
replace this equipment.


2-1 Unpacking
If there is a possibility for future relocation of the LightSmart-PE150
system, please save the cartons and protection packaging material. The
following items are shipped with your LightSmart-PE150
One LightSmart-PE150 users manual, AC power cord and DB9 cable.
One (or numerous units of) LightSmart-PE150 chassis system

Please carefully unpack and inspect the unit and accessories for
potentially damaged and missing parts. Contact our nearest sales
representative or our company directly if you suspect any damaged or
missing parts. Improper handling during shipment may cause early failure.

2-2 Site Requirement
The F.C.C. requires telecommunication equipment to withstand electrical
surge that may result from lighting strikes. This equipment has been tested and
found to comply with the F.C.C. requirement. Users should follow the
precautions below to insure the safety and minimize the risk of damage to the
equipment
Make sure that the power outlet is properly grounded.
Proper grounding should include a minimum of
1) A grounded rod buried outside the building at least 8 feet (2.44 meters)
deep.
9
2-3 Site Selection
The LightSmart-PE150 to allow easy access to the equipment, leave at
least 36 inches (90 cm) clearance in the front and at least 4 inches (10.2 cm)
at the rear.

To avoid overheating, leave at least 1 inch (2.5 cm) on either side of
LightSmart-PE150. Also, do not stack other equipment on top of
LightSmart-PE150.


2-4 DC Electrical Outlet Connection
For safety and to prevent damages to LightSmart-PE150, make sure that
the power requirement matches those of your electric outlets. Connect power
to LightSmart-PE150 and power on the equipment.


2-5 Laser Safety
Radiation emitted by laser devices can be dangerous to human eyes.
Avoid eye exposure to direct or indirect radiation.













10
Chapter III Panel Description
3-1 Front Panel






(1) OE Module LSRON LED ' Yellow light when the laser is on
LOS LED ' Red light when there is a loss of signal
WK LED ' Working path indicator
RX ' Optical Receiver Port
TX ' Optical Transmitter Port
(2) Order Wire Port Earphone and Microphone jack for order wire application
(3) CAL Button Activate/deactivate the order wire
(4) EXT CLK Port External clock input which can be 2,048 MHz TTL CLOCK or E1
PCM data port
(5) LAN Port RJ -45 connector to SNMP management system
(6) ACO Button Alarm Cut Off; Yellow light when the ACO button is pressed to
manually disable the audible alarm when a problem occurs.
If any newer alarm is reported after the ACO button has been pressed,
the external alarm will activate again.
(7) MAJ LED Red light when there is a Major Alarm present
(8) MIN LED Yellow LED lights when there is a Minor Alarm present
(9) LBK LED Yellow LED lights when there is a loopback function presents.
(10) RDI LED Remote Defect Indication;
Indicates a failure in the remote terminal
(11) PWR LED Green LED lights when power module active.
(12) LCK LED Optical link Lock; Locks the system if switched to protect line 6 times
within 10 minutes
(13) RNG LED Yellow LED lights when the order-wire function is active.
(14) ACO LED Alarm Cut Off function indicator
(15) Alarm Port DB9 female connector; connects to an external BUZZER to receive
visible and audible alarm. --Reference Page82(A-1)
(16) Craft Port For VT-100 screen setup using.
(17) RST Button Restart the system
(18) Button Three control and configuring buttons for LightSmart-PE150


11
3-2 Rear Panel






Power Switches: On/Off switch for LightSmart-PE150


LightSmart-PE150 provides three kinds of tributary interfaces card
and different power supply combinations with the DC/AC power supply.
(Details reference to Order Information)

(a) E1U tributary card
One DB-25 pins female connector for input/output of 4 channels E1 signal.
There are two types of E1 cards for selection: 75 or 120 .








(b) EthU tributary card
One RJ 45 port to remote terminal. Supports 10/100M Ethernet.








12

(c) 4V35 tributary card
4*V35 card, HD68 to 4*M34 Connectors to V.35 interface.









(d) 1V35 tributary card
1*V35 card, on board M34 Connectors for V.35 interface.









Any kind of the above cards is allowed to plugged into tributary slot 1~4.
(TB1~TB4)













13
Chapter IV VT-100 Operating Instructions
The LightSmart-PE150 control card provides two kinds of operation
interface. One is Craft port for local provisioning; the other is LAN port for
remote provisioning of the system.
* Craft Port
1. Any PC running Windows 98/2000 or NT can be used as a console.
2. Use the supplied RS-232 cable and connect the console port to the
COM port of console PC.
3. Use windows Hyper Terminal program to perform the console
management operations. But, we strongly recommend using the free
software netterm which has some of special function key to control
easily.
4. VT-100 terminal settings
Bit Rate 57600 bps
Data Bit 8 bits
Parity No Parity
Stop Bit 1 Stop bit
Flow Control: none
Set the emulation mode toVT-100 or Auto Detect

* LAN port
1. Using RJ -45 connecting to SNMP management system
2. LAN port system configuration










14
4-1 Booting and Login Screen
The system has the built in self-diagnostic function during the booting
procedure. The self-diagnostic function includes system memory access test,
system main clock test and tributary card access test. After power on the
system, the booting test screen can be shown before the login screen seen:













Enter LightSmart-PE150 Login Screen through Craft Port. Please key in
the User Name and User Password.
The default user Name is admin and the password is 1234














T L NR+Dshgrqs Rc j c amk k sl ga_ rgml wqrc k q 1 gk grc b ,
U c j amk rm 1 gef rk _ pr+NC/3.
mmrgl e 1 gef rk _pr+NC/3. ` w Npmdgj c G
15
4-2 Main Menu



















Notice : Some terminal programs could not support the function keys.

After entering the main menu, select one of the nine functions:
1. System Configuration
2. Tributary Slot Parameters Configuration
3. Optical Interface Parameters Configuration
4. Performance Management Threshold Configuration
5. Fault Management Parameters Configuration
6. External Clock Configuration and Monitoring
7. OE Protection Switching
8. Equipment Status Monitoring
9. Performance Monitoring
a. Path Alarm Monitoring
b. Loopback/V.54 Testing
c. PRBS Testing
d. Event Browsing
-- refer 4-3
-- refer 4-4
-- refer 4-5
-- refer 4-6
-- refer 4-7
-- refer 4-8
-- refer 4-9
-- refer 4-10
-- refer 4-11
-- refer 4-12
-- refer 4-13
-- refer 4-14
-- refer 4-15
Press the Function keys can access the item faster.
[F3] is online help, and has definition of the function key
Current location Show system name
16
4-3 System Configuration

















System Configuration the menu include the following selections:
1) System Information Configuration
2) Device Networking Configuration
3) User Account Management
4) SNMP Agent Configuration
5) Software Upgrade Configuration
6) Software Upgrade and Reboot Operation
7) Network Time Synchronization
8) Scheduling J ob Management
9) Networking Service Management
a) Network Troubleshooting Operation
b) LCD Login Configuration
c) Event parameter Management
d) System Profile Management

Press <F1>function key to select item 1 ~item d, and use the up or down
key to shift the items.
Please select the item or <ESC>to previous menu.

The detail description of each item will be mentioned in the following sections.
Notice : First of all, user need to select Local or remote units for configuration.
17
4-3-1 System Information Configuration



















The system administrator can key in the System Name by less than
256 characters words, the location of the system, and the contact person.

The system clock can be set by entering the correct time. This
screen can show the running time of the system and the software version.

After the setting of above items, please make sure to press <F2>to
save them.








Notice : Here shows the local or remote device which you selected.
18
4-3-2 Device Networking Configuration



















The system administrator can set the system device IP in this screen.


















19
4-3-3 User Account Management



















LightSmart-PE150 provides three kind of the user groups.
Admin the administrator group account can execute all functions.
Control the controller group account can execute all functions except
the System Configuration.
Monitor the monitor group account only can monitor the system except
that execute setting command.










20




















The default Auto-Logout Seconds is 0, which means disable the
auto-logout function.

This account also can disable the account status.















21
4-3-4 SNMP Agent Configuration


















The LightSmart-PE150 can assign four sets of the Server IP address for
sending the Traps.
The default Read Community is public.
The default Write Community is private.
The default Trap Community is public.

Enable the Send SNMP Authentication Failure Trap function for sending
the trap when the authentication is fail.









22
4-3-5 Software Upgrade Configuration

Remote Server





















LightSmart-PE150 can support two kinds of the System Software Upgrade
Remote Server and Local File

For Remote server source selection:
Access Protocol: select the protocol you want to use.
Server IP Address: the server IP address where the new firmware saved.
File Name: the file name of new firmware.
Login User Name: key in the remote servers user name.
Login Password: key in the remote servers password.




Press the Space bar can change the selected
23

Local File


















For Local File source selection: The screen will show the available file
stored in the system.

















24
4-3-6 Software Upgrade and Reboot Operation


















This function which is upgrading the local or remote unit, or reboot
the unit ,meanwhile , user needs to complete the setting of the software
upgrade configuration.


When user selects the [F3] Reboot commend item in local or remote side, it
will show the message:

"Start rebooting!",
"Ongoing!",
"Complete, Bye-!",
"None"






25

When user execute the Upgrade commend item in local or remote side, it
will show the status:

"Start upgrading!",
"Connecting!",
"Transferring!",
"Loading!",
"DeCompressing!",
"Flash writing!",
"Sending!",
"Upgrading complete!",
"Error!",
"None"


When the software upgrade error, it will show one of the following error
message:

"Internal error!",
"Local file not found!",
"Information incomplete!",
"Upgrading is running!",
"Connect failed!",
"Transfer failed!",
"Read failed!",
"Image file too large!",
"Disconnect failed!",
"Decompress code failed!",
"Invalid image format!",
"Abort by user!",
"None!"


26

When the screen of entering booting, please select a profile for loading.

If doesn't press any key then system will auto download the previous profile
after three seconds.

If you want to hold the screen, please press any key.
































27
4-3-7 Network Time Synchronization

















The system provides the network time synchronization function.
Setting the clock server IP address and time zone, then execute the Start
synchronizing command. The system clock will be automatically
corrected via Internet.


When user selects the synchronization commend item in local or remote side,
and "running status" will show the following message:


"Start Synchronizing!"
"Synchronizing!",
"Synchronizing Complete!",
"Synchronizing Error!",




28

When any error of synchronize occured one of error message will show as
below:

"Internal Error!",
"Information Incomplete!",
"Synchronization is running!",
"Time Get Error!",
"Abort by user!",
"Timeout!",
"No Error"



























29
4-3-8 Scheduling Job Management



















The Scheduling J ob Management function provides the automatic
timely reporting capability. The system administrator can arrange the
schedule for every kind of job. The job description is following as below.















30



















J ob Type: Periodic / One shot / Booting
Schedule Type: Every Interval / Every Day
Interval/Time: Setting the interval time
J ob: Send Schedule Trap
Send Time Sync Request Trap
Software Upgrade
Network Time Synchronization
System Reboot




You can press the Space bar to change the selected item.




31
4-3-9 Networking Service Management


















The system can turn on or turn off the functions of the SNMP Agent,
TELNET Server, and FTP Server.


















32
4-3-10 Network TroubleShooting Operation


















This function can test the equipment whether the unit link to network
or not. The system provides the Network TroubleShooting function.

Setting the Target IP address, Packet Count, Length and Timeout
Seconds, then first execute to Confirm[F2], and then execute Ping start[F5].




Note: The system device IP is must be set up








33

When target IP ping succeed, it will show as below:



















When target IP no answer, it will show as below:


















34
4-3-11 LCD Login Configuration


















User need to define the login password by the key on the front
panel in sequence. From key 1 to key 4.









Up contrast the upward key of the panel
Right contrast key right of panel
Down contrast the downward key of the panel






35
4-3-12 Event Management


















LightSmart-PE150 provides Event Management function, includes
Event Class Processing Configuration Event Alarm Processing
Configuration
















36
4-3-12.1 Event Class Processing Configuration


















The event class processing configuration function can set the events of
the configure, alarm, and operation to save in the flash or to send the trap.


N is not save in the flash or not to send the trap
Y is save in the flash or to send the trap













37
4-3-12.2 Event Alarm Processing Configuration


















The event alarm processing configuration function can set the different
severity of the events to save in the flash or to send the trap.

There are four classes of the alarm severity:
1. Critical
2. Major
3. Minor
4. Warning









38
4-3-13 System Profile Management


















4-3-13.1 Profile Save Parameter Config

















LightSmart-PE150 provides Auto-Saving function, and the auto saving
interval.
39
4-3-13.2 Profile Operation


















The system provides two booting profiles: Profile1 and Profile2.
If the profile had been changed before during the configuration processing,
the Profile Modification will show Y.

You can select either profile I or II then press <F2>function to save it,
and after that the next booting process will automatically configure the
system just like you save before.












40
4-4 Tributary Slot Interface Selection


















LightSmart-PE150 provide three tributary interfaces
(1) E1 Interface Configuration
(2) V.35 Interface Configuration
(3) Ethernet Interface Configuration

The Tributary TSA Configuration is used for the specific applications as
regard the time slot assignment of E1 and V.35 signal.










41
4-4-1 E1 Interface Configuration
























You can edit E1 Parameters for each channel or all channels of selected.

[F6] Slot Edit- Edit the parameters of all channels in the same slot.
[F7]/ [F8]- You can just press [F7] or [F8] to let the selected channels in the
screen go into the In-service state or out of service

If the EOC connection is closed, a symbol - will be shown for each
configuration.

[F2] Edit channel screen as below

[F3]: Select local, remote or both site by space
bar, then press the Enter key to select it.
[F5]: Select channel ID which you want to
change the configure.
[F4]: Select 1~4 slots or all by space bar.
42


















LightSmart-PE150 have two service mode which can select
OOS Out of service'
IS In service'

There are three types of E1 services: FAS+CRC, FAS only, Unframed

There are two types of E1 Line Coding: HDB3 or AMI















43
4-4-2 V.35 Interface Configuration
















If the EOC connection is closed, a symbol - will be shown for each
configuration.


[F2] Edit channel screen as below

















44

You can set the polarity of Tx or Rx clock to fit the requirement of different
kind of DTEs.

PCM31: 64K~1984K
PCM30: 64K~1920K
Unframed: 2048K


To have a stable V.35 configuration performance, you must make sure to
have set the correct clock mode. The following is the example of setting.


(1)












(2)












Date Rate
DTE DTE
LIGHTSMART-PE150 LIGHTSMART-PE150
Internal Recovery
DCE CLK DCE CLK
DTE DTE
LIGHTSMART-PE150 LIGHTSMART-PE150
EXT-DTE Recovery
INT DCE CLK
45
4-4-3 Ethernet Interface Configuration

















If the EOC connection is closed, a symbol - will be shown for each
configuration.

[F2] Edit channel screen as below

















46
4-4-4 Tributary TSA Configuration


















LightSmart-PE150 provides five kinds of the Tributary TSA(Time slot
assignment) :
1. 2E1+2V.35 (Two E1 channels and two V.35 channels)
2. 7E1+1V.35 (Seven E1 channels and one V.35 channel)
3. 3E1+1V.35 (Three E1 channels and one V.35 channels)
4. CH4<->CH5 (Four E1 channels and one V.35 channels)
5. Normal


Note:
The V.35 interface setting will be set to OOS (out of service) when the mode1~4
set to the V.35 interface. Be sure to set the V.35 to IS(in service) and check the
related configuration after the mode1~4 used to.

The Remote select, or will disappear, when the Eoc commection is closed.


47


1. Two E1 channels and two V.35 channels mode






















In this mode, user can also do the PRBS test which is like the figure as
above. The remote side channel can generate the test pattern to
corresponding channels in the local side.

Remote (4E1 card) Ch1 Locals (4E1 card) Ch1
Remote (4E1 card) Ch2 Locals (4E1 card) Ch2
Remote (4E1 card) Ch3 Locals (V35 card)
Remote (4E1 card) Ch4 Locals (V35 card)

Locals (4E1 card) Ch3
Locals (4E1 card) Ch4


Note: To avoid unexpected error, DO NOT insert any card in TB2 and TB3 at
4 3 2 1
4 3 2 1
4E1 card
(Slot 1)
V35 card
(Slot 2)
V35 card
(Slot 3)
Remote
Local
These 2 channels are unavalible, when TSA function
mode 1was turned on. They will be switched to "Out of
Service" automatically if original setting is "In Service".
TB1
TB1 TB2 TB3
2E1+2V.35
mode
Normal mode
4E1 card
(Slot 1)
48
remote side, while TSA function was turned on.

2. Seven E1 channels and one V.35 channel mode

























In this mode, user can also do the PRBS test which is like the figure as
above. The remote sides channel generates the test pattern to corresponding
channels in the local side.

Remote (4E1 card) Ch1 ~Ch4 Locals (4E1 card) Ch1~Ch4
Remote (4E1 card) Ch5 ~Ch7 Locals (4E1 card) Ch5 ~Ch7
Remote (4E1 card) Ch8 Locals (V35 card)


Note: To avoid unexpected error, DO NOT insert any card in TB3 at remote side,
8 7 6 5
Remote
Local
8 7 6 5 4 3 2 1
4 3 2 1
TB1 TB2
TB1 TB2 TB3
Normal mode
7E1+1V.35
mode
4E1 card
(Slot 1)
4E1 card
(Slot 2)
4E1 card
(Slot 1)
4E1 card
(Slot 2)
V35 card
(Slot 3)
49
while TSA function was turned on.

3. Three E1 channels and one V.35 channels mode






















In this mode, user can also do the PRBS test which is like the figure as
above. The remote side channel will generate the test pattern to
corresponding channels in the local side.

Remote (4E1 card) Ch1 Locals (4E1 card) Ch1
Remote (4E1 card) Ch2 Locals (4E1 card) Ch2
Remote (4E1 card) Ch3 Locals (4E1 card) Ch3
Remote (4E1 card) Ch4 Locals (V35 card)



Note: To avoid unexpected error, DO NOT insert any card in TB2 and TB3 at remote
side, while TSA function was turned on.

4 3 2 1
4 3 2 1
Remote
Local
TB1
TB1 TB2
3E1+1V.35
mode
Normal mode
V35 card
(Slot 2)
4E1 card
(Slot 1)
4E1 card
(Slot 1)
50


4. Four E1 channels and one V.35 channel mode

























In this mode, user can also do the PRBS test which is like the figure as
above. The remote sides channel generates the test pattern to corresponding
channels in the local side.

Remote (4E1 card) Ch1 ~Ch3 Locals (4E1 card) Ch1~Ch3
Remote (4E1 card) Ch4 Locals (V35 card) Ch5
Remote (V35 card) Ch5 Locals (4E1 card) Ch4


Note: To avoid unexpected error, DO NOT insert any card in TB3 at remote side,
5
Remote
Local
ch
5
4 3 2 1
TB1 TB2
TB1 TB2
Normal mode
CH4 <-> CH5
Mode
(4E1+1V.35)
ch ch ch ch
4 3 2 1
V35 card
(Slot 2)
4E1 card
(Slot 1)
V35 card
(Slot 2)
4E1 card
(Slot 1)
51
while TSA function was turned on.

5. Normal mode

















In the normal mode, every channel can also do the PRBS testing with the
corresponding channel in the remote side.



Notes: The clock setting needs to comform, please refer to the following
pictures.












Remote
Local
52


(1)









In this case, the right hand of E1 equipment is set to internal clock.



(2)








In this case, the right hand of E1 equipment is set to receive clock.

When V35 data is connected with E1 data, the related timing clock should be
set carefully to get more stable connection!!











EXT

INT
V35
LIGHTSMART-PE150 LIGHTSMART-PE150
V35
DTE
E1 INT CLK
E1
INT
EXT
DTE
LIGHTSMART-PE150 LIGHTSMART-PE150
V35
DTE
E1

E1 RX CLK
RX
CLK
RCV
V35
53

4-5 Optical Interface Parameters Configuration


















[F2] Edit channel screen as below


















54

' [F4]ALS (Auto Laser Shutdown) : Please refer to the definition of ITU-T G.664,
when LightSmart-PE150 detects LOS and the
ALS function is enabled at the same time, then
OE will shutdown the signal of Tx. It will detect
the signal automatically by every 100 seconds.
If the alarm of LOS doesnt erase immediately,
then it needs to wait another 100 seconds again.
If the LOS status clear, the system will return to
morncal state and transmit laser signal again.

' [F6] APS (Auto Protection Switch): While OFF selecting, OE Revertive/
OeLocked/ OeLocked Rule/ OE Lock AutoRel
Sec will disappear.
' [F7] OE Revertive: When [F7] set to OFF, OeLocked/ OeLocked Rule/ Oe Lock
AutoRel Sec will disappear.
' [F8] OE Locked: When [F8] set to OFF, OeLocked Rule/ Oe Lock AutoRel Sec
will disappear.
When [F8] set to ON:
' OE Locked Rule: Locks the optical system if switched to protect line m times
with in n minutes. (n and m depends on users definition )
(Default: m=6 ; n=10 )
' OE Locked AutoRel Sec: If the function of OE Locked has enabled, it will be
auto-release after x seconds. (Default: x=3600)


Note: If the function of the OE Locked has activate, then it needs to be realeased as
the screen of 4-9 OE Protection Switching
Note: User can't configure the disappeared function, when user reboot the equipment
which is reload the default value.



55
4-6 Performance Management Threshold Configuration


















This function means that when the PM value is equal or over the
thresholds value then it will issue the TCA alarm.

If TCA alarm is enabled, the alarm of TCA will be realease after is
min/day.

If the value is 0 the TCA will be unabled.


(1) E1 Interface Threshold Setting: Electrical interface threshold setting.
(2) Aggregate Interface Threshold Setting: Optical interface threshold
setting.






56
4-6-1 E1 Interface Threshold Setting

















You can use the function keys to modify the selected traffic link,
there are two PM types for choice: the quarter (15 minutes), the day
(24 hours).



[F6] Disable Unable the PM TCA alarm on the selected E1 path by high
light bar.
[F7] All Disable Unable the PM TCA alarm on the all selected E1 pathes
by the selection filters.








57



















[F1] Line
LCV: Line Code Violation
LES: Line Error Second
LSES: Line Several Error Second

[F3] Path
PCV: Path Code Violation
PES: Path Error Second
PSES: Path Several Error Second







58
4-6-2 Aggregate Interface Threshold Setting


















You can use the function keys to modify the selected traffic link, there
are two PM types for choice: the quarter(15 minutes), the day(24 hours).


















59
4-7 Fault Management Parameters Configuration


















LightSmart-PE150 provides fault management function by setting the
alarm severity for each failure alarm.
















60
4-7-1 Alarm Severity Config


















If the alarm severity configured as Critical or Major, the MAJ LED
will be turned as red when alarm occurred. Otherwise, Minor and
Warning alarm will make MIN LED turned on as yellow.
















61
4-7-2 Power Failure Monitoring Parameter Config



















Provide the function of power monitoring.

When ON is selected and the power module is failed, the alarm
will be issued.









62
4-8 External Clock Configuration and Monitoring


















To provide more stable synchronous for the system, you can use
the build-in optional external clock module.

Provide the extra external clock input for the whole systems reference.














63
4-8-1 External Clock Config

















User can select OOS or IS to turn on or off the external clock input.

When the EOC connection is failed or the External clock module is
unequipped, the configuration will disappear.



EXT CLK_pin_assignment








Pin 1 and Pin 2 of RJ45 are used for E1 PCM data or TTL Clock input



front view of RJ45 type connector of LightSmart-PE150'
64
4-8-2 External Clock Monitoring



















If the External Clock Module is bounded, the EquipState will be
Equipped, in other words, Unequipped will be shown while the module is
absent.














65
4-9 OE Protection Switching

















User can make the active OE module locked or released and OE
module menual restart from this screen.

1.Configuration:
Shown the configuration of APS (Automatic Protection
Switching), ALS (Automatic Laser Shutdown), Rvt (revertive
operation), LCK (lockout the active OE module) from section 4-5
Optical Interface Parameters Configuration.

2.OE Protection Switching Status:
Shown the current status of active OE module, the status of
Lock-out mechanism, the OE module switched times by automatic or
manually, and the seconds left for release after locked state. The
Lock-out mechanism can be activated or deactivated by command
OE Lock/Release [F2] on the aggregate interface. Some parameters
are configured at 4-5 Optical Interface Parameters Configuration.

3.OE Status:
Shown the alarm and laser status of the OE modules. the shut
down lasers can be restarted by command OE Restart [F4] and OE
Restart-Test [F5] on the OE interfaces.
1 2
3
66
Automatic laser shutdown and restart concept
The ALS mechanism implemented in LightSmart-PE150 is refered to
the ITU Recommendation ITU-T G.664. The ALS mechanism can be
enabled or disabled in 4-5 Optical Interface Parameters Configuration.


<< Flow Chart>>
































Automatic restart Manual OE restart Manual OE restart for test
Delay time (100s)
Tx on for (2s) Tx on for (2s) Tx on for (90s)
Start
ALS opertion enable
Receive signal from far end?
Loss of received signal
Auto power shutdown
Yes
Yes
No
No
67
4-10 Equipment Status Monitoring
On the equipment status monitoring screen, user can take an overall
view of the alarm status of the interlinked rack systems.


































- is for normal
F is for Failure
G is meaning green LED
R is meaning red LED
Y is meaning yellow LED
is meaning the device is absent
B is for E1 Balances (75 )
U is for E1 Unbalances (120 )
[Pwr] -- is power supply
FAN -- is fan monitor
H is for external alarm occurred
L is external alarm normal
68
4-11 Performance Monitoring


















The performance monitoring screen will show the valid quarters and
valid days had been counted for each card. Select the card and access to
next screen to see the detail performance data.



[F6] Reset: to clear all PM counters on the selected monitoring path

[F7] Reset All: to clear all PM counters on the All monitoring pathes









69



















PM Type have five kinds
1. CurrQuart Current Quarter'
2. HistQuart History Quarter'
3. CurrDay Current Day'
4. HistDay History Day'
5. Quarter Every 15 minutes'


[F2] Reset: to clear the selected PM type

[F5] Reset All: to clear all the PM type






70
4-12 Path Alarm Monitoring


















This screen shows all of alarm status for all monitoring path. Some
diagnostic testing work will cause alarm occurred, and the status of
loopback(V.54) and PRBS action shown as well.


The possible alarm for each interface is :
OE : LOS
Aggregate : LOF/RDI/AIS
E1 : LOS/LOF/RDI/AIS
V35 : LOS
Ethernet : LINK





Path Alarm Monitoring
71
4-13 Loopback/V.54 Testing

















For the diagnostic purpose, low speed E1 or V.35 data channel and
high speed aggregate signal can be locally loop-backed or remotely
loop-backed.
















72
Loopback Testing

There are four types of loopback functions for the E1 Module:

a. Tributary Local Loopback (for each E1 signal)
b. Aggregate Local Loopback (for all multiplexed E1 signals)
c. Aggregate Remote Loopback (for all multiplexed E1 signals)
d. Tributary Remote Loopback. (for each E1 signal)

Users can select whether to diagnose a specific channel or all channels under
the loopback / V.54 Testing.










a. Tributary Local Loopback: In the Loopback / V.54 Testing screen,
select the slot ID which is on the tributary card in the local site, then
choose LoLbk / ANA item.

b. Aggregate Local Loopback: In the Loopback / V.54 Testing screen,
select the aggregate item (Aggr/Lo) in the local site then choose
LoLbk / ANA item.

c. Aggregate Remote Loopback: In the Loopback / V.54 Testing screen,
select the aggregate item (Aggr/Re) in the remote site then choose
ReLbk / DIG item.

d. Tributary Remote Loopback: In the Loopback / V.54 Testing screen,
select the slot ID which is on the tributary card in the remote site then
choose ReLbk / DIG item.

Notice: In the E1 module, the REM is not able to choose, because REM
is only for V.35 module using.
Local site Remote site
73

There are three types of loopback functions for the V.35 Module:

a. Analog (ANA) Loopback:
b. Digital (DIG) Loopback
c. Request Remote (REM) Loopback














a. Analog (ANA) Loopback: In the Loopback / V.54 Testing screen, select
the slot ID which is on the tributary card in the local site, then choose
LoLbk / ANA item.

b. Digital (DIG) Loopback: In the Loopback / V.54 Testing screen, select
the slot ID which is on the tributary card in the local site, then choose
ReLbk / DIG item.

c. Request Remote (REM) Loopback: In the Loopback / V.54 Testing
screen, select the slot ID which is on the tributary card in the local site,
then choose REM item.









c.
DTE
Optical
Local Site Remote Site
a.
b.
V35 card V35 card
DTE
74

Notice function key [F8]
If the EOC (embedded channel) had broken such as in the aggregate
remote loopback state then [F8] Undo-AgReLBK can be used to re-built the
EOC channel. But, if optical signal lose, this function won't enable.

































75
4-14 PRBS Test





















The pattern of PRBS is 2
15
-1(unframing). Both E1 and V35 are able
to perform this testing.

In order to do the self-test, any E1 data link can be selected to have
a PRBS test. The tested result will be shown in the number of error bit as
well as its error ratio.

Regard as the PRBS test of TSA mode, please refer to the figures of
4-4-4.a and 4-4-4.b.


You can only choose one channel to generate or analysis at the same time.


Pattern Analysis
Pattern Generate
76

One way PRBS test step:





































Remote
Local
GEN
Ana
LIGHTSMART-PE15
LIGHTSMART-PE15
77

The round trip PRBS test function operating step.

























Please refer to the loopback test function to verify the loopback setting.

When user wants to do the PRBS test, firstly, the remote side needs to
set the loopback path (loop A, Loop B, Loop C) which depends on users
request. In the local device which will generate a test pattern to remote
device, then local devices analysis part will receive a test pattern through
the loopback path. Eventually, user will get a test result on the screen.



Remote
Local
GEN
Ana
Loopback
path A
Loopback
path B
Loopback
path C
LIGHTSMART-PE150
LIGHTSMART-PE150
78
4-15 Event Browsing

















Clear Ram Log [F4]: clear all history events after the system booted.

Clear Flash Log[F5]: If the event-saving function is be enabled. F5 will
clear all history events store in Flash memory.
(ref: 4-3-11.1 Event Class Processing Configuration /
4-3-11.2 Event Alarm Processing Configuration)










79
Chapter V LCD Operating Instructions
LightSmart-PE150 provides a easy way to set the configuration,
maintenance, and testing by LCD and button.








The default password for LightSmart-PE150 is a combination of the buttons as
below, from left to right:
Button Up Right Down Up



Note: the password for login in LCD menu can be changed via VT100 setting as
section 4-3-11.


Button functions are as follows:

Go back to the upper level of the menu
Item select
Enter key to go to a sub-menu or enable selected action









80
5-1 LCD Menu Tree
Passward: _ _ _ _ (Modify Password refer to 4-3-10)

---Tb Config
----E1 [Site/Slot/Ch]
----FrameType (FAS+CRC/FAS/OFF)
----LineCoding (HDB3/AMI)
----Service (IS/OOS)

----V35 [Site/Slot/Ch]
----TxClkSource (ClkSrc:Internal/Ext-DTE/Recovery)
----PCM/FrameMode (PCM30/PCM31/Unframed)
----DataRate (64K/128K/192K/256K/320K/384K/448k/512k/
576k/640k/704/768K/832K/896K/960K/1024K
/1088K/1152K/1216K/1280K/1344K/1408K/
1472K/1536K/1600K/1664K/1728K/1792K/
1856K/1920K/1984K/2048K)
----TxClkPolarity (Normal/Invert)
----RxClkPolarity (Normal/Invert)
----Service (IS/OOS)

----Eth [Site/Slot]
----Service (IS/OOS)
----AutoNeg (ON/OFF)
----Duplex (Full/Half)
----Speed (10M/100M)

----TSA [Site]
----TSA (Normal/ 2E1+2V.35/ 7E1+1V.35/
3E1+1V.35/ CH4<->CH5)

---Opt Config [Site]
----Working OE (1/2)
----ALS (ON/OFF)
----Standby OE (ON/OFF)
----APS (ON/OFF)

---External Clock
----Config [Site]
----Service (ON/OFF)

----Monitoring [Site]
----EquipStatus (Status:Equipped/Unequipped)
----AlarmMonitoring (Status:None/Normal/LOS)
81



---Oe Protect Sw
----Current Status [Site]
----WorkingOe (Status:1/2)
----OELocked (Status:-/ON/OFF)
----SwitchNo (Status:1-99)
----LeftRelSec (Status:1-99999)
----OE1Tx (Status:ON/OFF)
----OE2Tx (Status:ON/OFF)

---Oe Lock/Release [Site]
----Lock OE
(Status:(ON)/Release OE(DOWN))
----Lock OE
(Status:(OFF)/Lock OE(DOWN))

---Oe Restart [Site/Oeld]
----Restart DOWN
(Restart OK/ Restart fail)

---Oe Test [Site/Oeld]
----RestartTest DOWN
(RestartTest OK/ RestartTest fail)

---System
----Profile Operation [Site]
----Profile Id (1/2)

---FM Config
----Pwr Fail Mon Cfg [Site/ PwrID]
----Service Config (IS/OOS)

---Alarm Monitoring
----Equipment [Site]
----Pwr1 (Status:NoAlarm/Failed)
----Pwr2 (Status:NoAlarm/Failed)
----Fan (Status:NoAlarm/Failed)

----Path [Site]
----Alarm (Next)




82


--- Loopback/V.54[Site]
---- Aggr
----LLBK (ON/OFF)
----RLBK (ON/OFF)
----RRLBK (ON/OFF)
----UndoAgReLBK (ON/OFF)

----E1 [Slot/Ch]
---LLBK (ON/OFF)
---RLBK (ON/OFF)

---- V.35 [Slot/Ch]
----ANA (ON/OFF)
----DIG (ON/OFF)
----REM (ON/OFF)

--- PRBS Testing[Site]
---- E1 [Slot/Ch]
----PTGEN (ON/OFF)
----PTANA (ON/OFF)
----PTANA Result (Status:Error/BER)

----V.35 [Slot/Ch]
----PTGEN (ON/OFF)
----PTANA (ON/OFF)
----PTANA Result (Status:Error/BER)

--- Logout (DOWN)













83
Appendix
A-1 Carft Port Interface
Usual VT-100 interface:










Carft Port Pin Assignment

1. Craft port (VT100):










The voltage offset between positive and negative input: 3 ~ 60VDC
Input current range: 0.5 ~ 8 mA










Pin No. Signal
2 TxD
3 RxD
5 GND
Relay contact
VT100 port
ALARM
CRAFT
(Female)
for the default type of shipping
5 4 3 2 1
84

A-2 Rack Mount Installation Guide











































LightSmart-PE150-LOE-V1.1