An experts dream
The ED displays all its strengths during rough everyday operation.
Clear and easy-to-read indicator field which gives you all informa-
tion on regulating range, position of the motor drive unit and tap-
changer, tap change and number of changes even when the motor
drive unit is closed
Reflects the logical nodes YLTC, LLN0 and LPHD
For special requests also the LN ATCC (voltage regulator)
Modern cage-clamp terminal technology
Easy-to-access position signaling unit (position signaling module,
position signaling BCD) allows upgrading and later adaption to
future indicator technologies
Functional separation of position signaling BCD and position
signaling module
Low-noise transmission gear with maintenance-free belt gear as
transmission element
Uniformmounting and drive geometry for all ED models
Panel heater as full-performance anti-condensation heater;
thermostats or hygrostats are no longer needed
Intelligence inside
Are you looking for an on-site solution with integrated electronics
for direct regulation and monitoring of on-load tap-changers and
transformers? We have the answer. The serial interface IEC61850
lets the components communicate directly with your control system.
A
C
H
T
U
N
G
!
!
S
e
i
t
e
w
i
r
d
u
m
2
c
m
a
u
f
1
9
c
m
v
e
r
k
r
z
t
!
!
Motor drive ED 100 ED 200
Supply voltage 3 AC/N 230/400 V
Current 1.9 A 5.2 A
Frequency 50 Hz
Synchronous speed 1500 1/min
Rotation of the drive shaft per tap change 16.5
Runtime per tap change approx. 5.4 sec
Rotation of the hand crank per tap change 33
Max. number of operating positions 35
Voltage of control and header circuit AC 230 V
Power consumption of the control circuit 100 VA/25 VA
(activation/operation)
Heater power 50 W for ED 100/ 200 S 60 W for ED 100/ 200 L
Test voltage against ground 2 kV (50 Hz/60 Hz)
Weight ED 100/ 200 S: 80 kg / ED 100/ 200 L: 130 kg
VACUTAPVV, VR, VT X
OILTAPV, MS X
OILTAPM, RM, R X*
DEETAPDU X*
VACUTAP3xVR X*
OILTAP3xM, 3xRM, 3xR, 3xG X*
Technical data (standard model)
Type designation Description Variants
ED 100-ST Product designation Electric drive
ED100-ST Transmission gear 100 =small transmission gear
200 =large transmission gear
ED 100-ST Protective housing model S =small protective housing
L =large protective housing
ED 100-ST Special applications M =Monitoring
C =plunger-core earth-fault neutralizer
T =voltage regulator TAPCON240/260
fitted with IEC61850
LN YLTC, LLN0, LPHD (ATCC)
ED-Description of different models
* Please contact MR
The ED motor drive is also used in retrofit applications with on-load tap-changers made by other manufactures (e.g. Siemens, AEG, TRO).
Please contact MR for these applications.
www.reinhausen.com
Maschinenfabrik Reinhausen GmbH
Falkensteinstrasse 8
93059 Regensburg, Germany
Phone (+49) 9 41/40 90-0
Fax (+49) 9 41/40 90-111
E-mail sales@reinhausen.com
Please note: The data in our publications may differ fromthe data of devices delivered.
We reserve the right to make changes without notice.
IN294/01en 0806/1000 294/01/01/0 F0157500 dp Printed in Germany