You are on page 1of 4

Lighting Test Results

AUTOMOTIVE
Markham, Ontario
December 1st, 2009

Existing Core & GloGreen DHID Measured Amps. Being Dimming/


Coil Ballast HID Ballast fc / lx Consumed Re-strike Time

1. Directly Below (Centre)


High-bay ceiling High-bay ceiling
2. At 3ftFrom Centre
height 26 feet height 26 feet
3. At 6ft From Centre

1. 13fc / 240lx
No Dimming/
400W 2. 12fc / 230lx Not measured.
Re-strike 10min+
3. 20fc / 250lx

1. 50fc / 540lx Instant dimming/


250W 2. 50fc / 600lx Not measured. Re-strike is 4 min.
3. 40fc / 500lx approx.

1. fc / lx
200W 2. fc / lx Not measured. Not measured.
3. fc / lx

1. 20fc / 280lx Instant dimming/


150W 2. 20fc / 280lx Not measured. Re-strike is 4 min.
3. 20fc / 260lx approx.

Proposal to test 150W and 250W DHID vs. existing magnetic 400W MH HID System.
Start-up time: at 1minute the resulting lumen output was 40fc on the 250W setting.
Bulb type here is a standard clear; Venture UNI-Form MH 320W.

Anthony (Tony) Borges


Accendo Electronics Ltd.
________________________________________________________________________________________________________
Head Office: 160 Gibson Dr., Unit 9 Markham, Ontario, Canada L3R 3K1
Phone: 905-475-2067 www.accendoelectronics.com
Lighting Test Results

AUTOMOTIVE
Ontario
November 17, 2009

Existing Core & GloGreen DHID Measured Amps. Being Dimming/


Coil Ballast HID Ballast fc / lx Consumed Re-strike Time

1. Directly Below (Centre)


High-bay ceiling High-bay ceiling
2. At 3ftFrom Centre
height 26 feet height 26 feet
3. At 6ft From Centre

1. 13fc / 153lx
No Dimming/
400W 2. 13fc / 144lx Not measured.
Re-strike 10min+
3. 10fc / 112lx

1. 69fc / 730lx Instant dimming/


250W 2. 47fc / 506lx Not measured. Re-strike is 4 min.
3. 30fc / 322lx approx.

1. 46fc / 487lx Instant dimming/


200W 2. 32fc / 345lx Not measured. Re-strike is 4 min.
3. 21fc / 218lx approx.

1. 28fc /302 lx Instant dimming/


150W 2. 21fc / 237lx Not measured. Re-strike is 4 min.
3. 13fc / 140lx approx.

Anthony (Tony) Borges


Accendo Electronics Ltd.
________________________________________________________________________________________________________
Head Office: 160 Gibson Dr., Unit 9 Markham, Ontario, Canada L3R 3K1
Phone: 905-475-2067 www.accendoelectronics.com
Lighting Test Results

AUTOMOTIVE
Aurora, Ontario
November 17, 2009

Existing Core & GloGreen DHID Measured Amps. Being Dimming/


Coil Ballast HID Ballast fc / lx Consumed Re-strike Time

1. Directly Below (Centre)


Low-bay ceiling Low-bay ceiling
2. At 3ftFrom Centre
height 20 feet height 20 feet
3. At 6ft From Centre

1. 31fc / 347lx
No Dimming/
250W 2. 28fc /333 lx Not measured.
Re-strike 10min+
3. 25fc / 273lx

1. 86fc / 910lx Instant dimming/


250W 2. 65fc /720 lx Not measured. Re-strike is 4 min.
3. 44fc / 470lx approx.

1. 67fc / 732lx Instant dimming/


200W 2. 45fc / 490lx Not measured. Re-strike is 4 min.
3. 28fc / 306lx approx.

1. 46fc /507 lx Instant dimming/


150W 2. 32fc / 352lx Not measured. Re-strike is 4 min.
3. 21fc / 237lx approx.

Proposal to test DHID ballast powered HID versus


magnetic 250W Stingray MH HID System.

Frosted EYE 320W bulb tested; excellent brightness, pleasant white light
penetration to the ground and surrounding area

Anthony (Tony) Borges


Accendo Electronics Ltd.

________________________________________________________________________________________________________
Head Office: 160 Gibson Dr., Unit 9 Markham, Ontario, Canada L3R 3K1
Phone: 905-475-2067 www.accendoelectronics.com
Results of Lighting Test
Honeywell Consumer Products
(Stratford, Ontario, Canada)
November 3, 2009

New Accendo Foot Candles


Existing Amps. Being
GloGreen Produced @ Re-strike Time
Magnetic Ballast Consumed
Digital Ballast Floor Level

Low Bay
Ceiling 15 feet

250W 37 2.5 Over 5 minutes


250W 180 2.2 3 min. 45 sec.
150W 75 1.3

High Bay
Ceiling 22 feet

400W 23 4.0 Over 5 minutes


250W 86 2.2 4 min. 30 sec.
200W 50 1.8

________________________________________________________________________________________________________
Head Office: 160 Gibson Dr., Unit 9 Markham, Ontario, Canada L3R 3K1
Phone: 905-475-2067 www.accendoelectronics.com