You are on page 1of 21

DCS CABINET

Main Office:
FIRESPEC ENGINEERING (M) SDN BHD
No. 26-1, Jalan Damai Perdana 1/8B, Bandar Damai Perdana Cheras, 56000 Kuala Lumpur.
Phone : +603 9100 5718 Facsimile : +603 9100 4586
E-Mail : support@firespec.net
http://www.firespec.net
Automatic Fire Detection and Suppression
What do we do?
We stop this from happening
We have never had a fire!
Causes of Fire
Short Circuit
High Speed/Friction
Broken Tool
Operator Error
What is Firetrace?
Self-contained automatic fire
detection and suppression
system
Pneumatic linear heat/flame
detector
Detection and suppression
at the ignition point!
Put the fire out where and
when it starts, not after your
expensive machinery or
building is destroyed!
How the Tubing Works
Tubing bursts at the point
closet to Flame or Heat
when it reaches 212 Degrees
Fahrenheit creating a
Discharge Nozzle!
Electrically non-conductive
Firetrace Detection Tubing is a
linear pneumatic fire/heat
detector
Firetrace
Detection
Tubing
Requires
No Power
Easy
Installation
Cost
Effective
Tolerates the
vibration, dirt,
and
temperature
extremes of
many different
environments
Heat sensitive
polymer tubing
reacts to heat
and radiant
energy of a fire
by bursting,
thus releasing
the fire
suppressant
agent
Flexible tubing!
New systems
or retrofits are
easy to install and
maintain
Rapid detection
and rapid
suppression to
quickly reduce
damage and
risks
Firetrace Advantages
DCS Cabinet
Electrical Switch
Flexible Tubing allows us
to provide detection and
suppression almost anywhere
Detection and Suppression at
the critical point DCS Cabinet
Tube Burst Point -
the suppression agent
was delivered straight
onto the heart of the
fire
Actual Suppressions
Clean Agent System
Indirect Low Pressure
Low Pressure Medium
Cross Pattern Nozzles
Detection Tubing
Manual Release
Indirect Low Pressure
Clean Agent System
Clean Agent System
Indirect Low Pressure
Low Pressure Medium
Cross Pattern Nozzles
Detection Tubing
Manual Release
Indirect Low Pressure
Clean Agent System
Firetrace
Installations
Other Machine Applications
Mist Collectors
EDM Machines
Dust Collectors
Screw Machines
Grinding Machines
The Risks
With Firetrace Without Firetrace
Cost of Protection
Lost Production
Lost Income
New Machine or
expensive repair
Higher Insurance
Rates
Risk
Analysis
System
Design
Installation
Identify critical
equipment and
processes
Type of Fire (Class)
Type of Agent
Type of System
(Direct or Indirect)
Volume of Area
Easy Installation and
Maintenance
Installs in, on or near
the machine
Pre-Engineered Systems
Firetrace Systems
Direct Low Pressure System
The Firetrace Tubing is both a
flame/heat detector and
discharge nozzle rupturing at
212 degrees Fahrenheit!
Indirect Low Pressure System
Tubing ruptures creating
pressure drop which releases
suppressant faster through
separate piping network!
Suppression Agents
Clean Agent
FM-200, FE-13, FE-25, FE 36, Novec 1230
Dry Chemical
ABC, BC, D (metals), D (lithium)
Other
CO2 and Foam
Fire Alarm Panels
Building Management
Systems
Equipment Shut Down,
shunt trip, fan/damper
control and more
Manual Release
Pressure
Switch
Interfaces
with
System Accessories
Manual Release (Double Action)
Pressure Switch (Cylinder and EOL)
Solenoid Valve
Smoke Detector
Audible Alarm
Time Delays
And more
Contact Information
Hj Azlan Abass
Technical Consultant
+6013 3922441
hjazlan@firespec.net