MW95A Belt Weigher System

Operation Manual
MW95A_Operation_Manual_SV3.60a EMC INDUSTRIAL GROUP LTD



THIS MANUAL APPLIES TO
MW95 Belt Weigher P-Module
MT6x & MT8x Transmitters
MW99d4 Flowrate Indicator
Transmitter software version number 3.60 onwards



















EMC INDUSTRIAL GROUP LTD
MW95A_Operation_Manual_SV3.60a Page 2 of 7








AVAILABLE DOCUMENTATION






















COPYRI GHT 2006 by EMC I ndustrial Group Ltd
56 Tarndale Grove, Albany, North Shore, Auckland 0632
PO Box 101 444 North Shore, Auckland 0745, New Zealand
Telephone +64-9-415 5110, Facsimile +64-9-415 5115
E-mail sales@emc.co.nz Web http://www.emc.co.nz/




As we are continuously improving our products, changes to this specification may occur without notice.

PRODUCT DESCRI PTI ON DOCUMENTATI ON
MW61 Loadcell Transmitter Setup Manual
Setup Summary
Operator Manual
MW93 Weight Change Transmitter Setup Manual
Setup Summary
Operator Manual
MW95 Weigh Belt Transmitter Setup Manual
Setup Summary
Operator Manual
MW96 Weighfeeder Transmitter Setup Manual
Setup Summary
Operator Manual
EMC INDUSTRIAL GROUP LTD Contents
MW95A_Operation_Manual_SV3.60a Page 3 of 7
Contents

Contents....................................................3
Introduction..............................................4
Display & Operating Elements ..................4
Display and operating elements.............................................. 4
Keys ..........................................................5
START.................................................................................. 5
STOP.................................................................................... 5
BATCH WEIGHT .................................................................... 5
SPEED DEMAND.................................................................... 5
PRINT................................................................................... 5
ZERO.................................................................................... 5
PRINT TOTAL........................................................................ 5
RESET TOTAL........................................................................5
ALARM..................................................................................5
SELECT.................................................................................5
MENU...................................................................................5
DISPLAY ...............................................................................5
Beeper.......................................................5
Menus........................................................5
Menu Selection......................................................................5
Menu Item List......................................................................5
Settings Adjustment Window..................................................6
Setup using an MW99d0 or MW99d4........7


EMC INDUSTRIAL GROUP LTD Introduction
MW95A_Operation_Manual_SV3.60a Page 4 of 7

Introduction
This manual describes the operation of an EMC MW99d4 Weight Indicator display when connected
to an EMC MW95 Loadcell Transmitter.


Display & Operating Elements
Display and operat-
ing elements






Identification of selected transmitter. Press SELECT key to view and select another
transmitter from list of transmitters connected.

Main display of measured value. Normally flowrate

Engineering unit main display is calibrated in.

Alarm Light flashes when an alarm is present.


Main display bar graph. Shows the flowrate.


Displays the totaliser. I f the Batch Weight is not zero, then it is displayed below the to-
taliser.

A group of annunciators described below.

clear
Belt is being cleared. The bar graph shows the progress.


zero
Automatic belt zeroing is in progress. The bar graph shows the pro-
gress.


load
The belt is being re-loaded. The bar graph shows the progress.


cal
A dynamic zero or span is in progress. The bar graph shows the pro-
gress.

7
6
5
4
3
2
1
1 2 3
6 7 9
4
8 5
EMC INDUSTRIAL GROUP LTD Keys
MW95A_Operation_Manual_SV3.60a Page 5 of 7

Material feed stopped


Paused

Zeroing status.

The bar graph shows the belt rotation, the line extends from zero to
full length over one belt revolution. The dots show that the platform
weight was within the zero band for each of the last 3 belt revolutions.
The absence of a dot indicates the weight was outside the band.



Secondary display shows one of a selection of values. Press DISPLAY key to scroll
through the list.

Menu key



Keys
START
Press this key to start the system. The light above the key will turn on.

STOP
Press this key to stop the system.

BATCH WEIGHT
Press this key to display the BATCH WEIGHT setting. Use the keypad to set the batch weight.

SPEED
DEMAND
Press this key to display the SPEED DEMAND setting. If the speed demand is set using the keypad,
the controller is automatically put into volumetric mode.
PRINT
Press the PRINT key to produce a Status Report printout.
ZERO
Press this key to start a belt zero cycle. The MATERIAL FEED output is used to clear the belt, then
the belt is zeroed over a full revolution, then the material is allowed back onto the belt.
PRINT TOTAL
Press this key to print the totalised weight.
RESET TOTAL
Press this key to reset the totalised weight.
ALARM
If the light above the ALARM key is flashing, then a new alarm is being reported. Press the ALARM
key to view a menu of current alarms. The light will become steady to show that the alarms have
been viewed.
SELECT
Identification of selected transmitter. Press SELECT key to view and select another transmitter from
list of transmitters connected.
MENU
Press this key to view the Operators menu.
DISPLAY
Press this key to select the next line at the bottom of the display.

Beeper
An internal beeper is used as an audible indication of key presses.

Menus
Menu Selection
Press the MENU key to show list of settings.
The left most number of each item corresponds to a key number used for quick item selection.
Pressing the ENTER key will step through each operator setting in turn. Or press the corresponding
quick key to go directly to the setting.
Menu Item List

9
8
EMC INDUSTRIAL GROUP LTD Menus
MW95A_Operation_Manual_SV3.60a Page 6 of 7



Menu name

Quick key number. Press key with same number to directly enter the named 13
menu.
1 batch preact The amount before the batch weight to stop batching
0 Exit menu Exit the menu to the normal operator display.



Name of menu item.


Settings Adjustment
Window



Setting name.


Engineering unit setting is calibrated in.


Indicates active keys or the prefered method of making a value change while
editing.


The setting is locked. Password must be entered to edit.


The setting can only be viewed.

3
2
1
1
4 5
3 2
3
2
1
1
2 3
EMC INDUSTRIAL GROUP LTD Setup using an MW99d0 or MW99d4
MW95A_Operation_Manual_SV3.60a Page 7 of 7

The setting has been changed from the default.


Press Fn key for menu of special settings.


Press EDIT key to edit setting.


The setting is being edited.


Use numbered keys to change setting value.


Use UP & DOWN keys to scroll through selection list.


Use UP & DOWN keys to set to ON or OFF



Hint line which reveals extra information about the setting.


Setting value. To change press EDIT key, key in changes then press ENTER key.




Setup using an MW99d0 or MW99d4
When using a MW99d0 or MW99d4 display to operate the Belt Weigher System, the functions on
the MW99 keys are not correct for the transmitter.
The MW99 will automatically display a menu when a function key is pressed. The menu items ex-
plain the function of the key that was just pressed. Press the key again to activate the function, or
use the UP and DOWN arrow keys to select a different function.

5
4

You might also like