HUAWEI TECHNOLOGIES CO., LTD.

www.huawei.com
Upgrading cabinet BTS 3900A
to version D
Prepared by QA& BSS team EJ Balom
HUAWEI TECHNOLOGIES CO., LTD.
Page 2
1. 2 pcs DCDU ver.D
2. FAN for RFC cabinet
3. Fan for TMC cabinet
4. power cable termination
5. ELU sensor
6. Power cable blue black
7. MCB requirement 80 A -120 A
8. BTS door for TMC cabinet


Preparation material completeness
RFC
cabinet
TMC
cabinet
HUAWEI TECHNOLOGIES CO., LTD.
Page 3
1. DCDU ver.D for RFC cabinet
2. DCDU ver.D TMC cabinet
3. FAN for RFC cabinet
4. Fan for TMC cabinet

Preparation material completeness
1
2
3
4
HUAWEI TECHNOLOGIES CO., LTD.
Page 4
4. power cable termination
5. ELU sensor TMC and RFC cabinet
6. Power cable blue black
7. MCB requirement 80 A -120 A


Preparation material completeness
4
5
6
7
HUAWEI TECHNOLOGIES CO., LTD.
Page 5
8. BTS door for TMC cabinet and fan ext cable



Preparation material completeness
8
HUAWEI TECHNOLOGIES CO., LTD.
Page 6
1. Cut ties cable on BTS 3900A
2. Power off BTS
3. Change DCDU and MCB
4. Install power cable termination and power cable
5. Change FAN in TMC and RFC cabinet
6. Connect RRU power cable to DCDU(load 7,8,9)
7. Change ELU sensor
8. Power on MCB
9. Replace BTS door on TMC cabinet



Installation Steps
HUAWEI TECHNOLOGIES CO., LTD.
Page 7
1. Cut ties cable on BTS 3900A



Installation Steps
HUAWEI TECHNOLOGIES CO., LTD.
Page 8
2. Power off BTS


Installation Steps
Dont forget insulating power
cable
HUAWEI TECHNOLOGIES CO., LTD.
Page 9
1. Power RRU to DCDU BTS 3900 A Ver.D in RFC cabinet
Power Outdoor Installation for RRU all type
Must use DCDU allocation load 7,8,9 (@30A)
HUAWEI TECHNOLOGIES CO., LTD.
Page 10
2. Power BBU Fan EMUA to DCDU BTS 3900 A Ver.D in TMC cabinet
Power Outdoor Installation for RRU all type
Load 4 EMUA power
Load 5 BBU power
Load 6 FAN power
Load 7, 8 ,9 spare RRU power
Load 7,8,9 Spare
RRU power
Load 6 FAN
power
Load 5 BBU
power
Load 4 EMUA
power
HUAWEI TECHNOLOGIES CO., LTD.
Page 11
2. Power BBU Fan EMU and RRU to DCDU BTS 3900 /L Ver.D
Power indoor Installation for RRU all type
Load 4 EMUA power
Load 5 BBU power
Load 6 FAN power
Load 7, 8 ,9 RRU power
Load 6 FAN
power
Load 4 EMU
power
Load 7,8,9 RRU
power
Load 5 BBU
power
HUAWEI TECHNOLOGIES CO., LTD.
Page 12
3. Change DCDU and MCB



Installation Steps
HUAWEI TECHNOLOGIES CO., LTD.
Page 13
4. Install power cable termination and power cable



Installation Steps
HUAWEI TECHNOLOGIES CO., LTD.
Page 14
5. Change FAN in TMC and RFC cabinet



Installation Steps
RFC
TMC
HUAWEI TECHNOLOGIES CO., LTD.
Page 15
6. Connect RRU power cable to DCDU(load 7,8,9)




Installation Steps
Load 7,8,9
HUAWEI TECHNOLOGIES CO., LTD.
Page 16
7. Change ELU sensor TMC and RFC cabinet




Installation Steps
HUAWEI TECHNOLOGIES CO., LTD.
Page 17
8. Power on MCB





Installation Steps
Before power on check all connection correct and tight
HUAWEI TECHNOLOGIES CO., LTD.
Page 18
9. Replace BTS door on TMC cabinet





Installation Steps
a. replace BTS door
Open the door bolt
Release the door and
FAN ext cable
HUAWEI TECHNOLOGIES CO., LTD.
Page 19
9. Replace BTS door on TMC cabinet





Installation Steps
b. Connect FAN EXT cable between BTS door and FAN
HUAWEI TECHNOLOGIES CO., LTD.
Page 20
9. Replace BTS door on TMC cabinet





Installation Steps
c. Attach SN BTS door etc sticker in BTS door
before
after
HUAWEI TECHNOLOGIES CO., LTD.
Power for RRU






BTS 3900A
ver.D
Type RRU
3829
3838
3638
3839



DCDU load 7,8,9
www.huawei.com
THANKS