You are on page 1of 4

Equipment for Engineering Education & Research

SOLTEQ

T
HE Liquid Diffusion Coefficient Apparatus (Model BP: 09) has been designed to allow for the measurement
of molecular diffusivities so that students will be able to understand the basic notions of mass transfer theory.
This liquid diffusivity apparatus relates to an equi-molal counter-diffusion process. The unit comes complete
with a diffusion cell, a transparent diffuser vessel, a stirrer system and a conductivity meter.
EXPERIMENTAL CAPABILITIES
Measurement of mass transfer rates.
Measurement of diffusion coefficients.
The effect of concentration upon diffusion coefficient.
First order unsteady state process analysis.
Familiarisation with laboratory instruments to obtain
data for industrial process design.
DESCRIPTIONS
The diffusion cell, the most important component, has
been designed for fast diffusion rates in liquids to minimise
long observation period. The cell basically consists of a
honeycomb of accurately dimensioned capillaries,
positioned between two liquids of differing concentration
of the solute whose diffusion coefficient is to be studied.
During the experiment, students shall place a small
volume of concentrated solution on one side of the
honeycomb. At the beginning, the other side of the
honeycomb consists of a large volume of pure solvent
(water). The solute diffuses from high concentration side
to the low side, causing the concentration within the larger
volume to increase. The mixture is continually stirred
while the increase in concentration is continuously
monitored using a conductivity meter.
SPECIFICATIONS
a) Diffusion Cell
b) Diffuser Vessel
Capacity : 1.0 litre
Material : borosilicate glass
c) Conductivity Meter
Range : 0- 1,999 S/cm
De-ionizer : 1.5 LPM of pure water
Equipment for Engineering Education & Research
SOLTEQ

d) Stop Watch
REQUIREMENTS
Electricity supply : 240VAC/1-phase/50Hz
Water supply : laboratory mains
OVERALL DIMENSIONS
Height : 0.450 m
Width : 0.250 m
Depth : 0.250 m
MANUAL
The unit is supplied with Operating and Experiment
Manuals in English giving full descriptions of the unit,
sumary of theory, experimental procedures and typical
experiment results.
Conductivity vs. time
y = 0.1745x + 789.8
y = 0.0812x + 461.2
y = 0.0339x + 264.73
0.0
200.0
400.0
600.0
800.0
1000.0
1200.0
0.0 200.0 400.0 600.0 800.0 1000.0 1200.0 1400.0 1600.0 1800.0 2000.0
Time, t [s]
NaCl = 1.0 M
NaCl = 2.0 M
NaCl = 4.0 M
Linear (NaCl = 4.0 M)
Linear (NaCl = 2.0 M)
Linear (NaCl = 1.0 M)
TYPICAL EXPERIMENT RESULT
Equipment for Engineering Education & Research
SOLTEQ

SOFTWARE & E-LEARNING


Our range of teaching equipment can be complemented with our
SOLDAS and SOLCAL software.
SOLDAS
TM
- Supervisory Control & Data Acquisition
- Data Logging
- Signal Analysis
- Process Control
- Real-Time Display
- Tabulated Results
- Graph of Experiment Results
SOLCAL
TM
- Computer Aided Learning
- Multimedia Features
- Interactive
- Graphic Simulation
- Samples of Experiment Result
- Full Experiment Manuals
Contact us for a catalog CD
SOLUTION ENGINEERING SDN. BHD.
(Co. No. 174876-M)
Sales Office :
No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara,
47100 Puchong, Selangor Darul Ehsan, Malaysia.
Tel. No. : +(603) 80758000
Fax. No. : +(603) 80755784
R&D Office :
G-2A, Incubator 3, Technology Park Malaysia,
Bukit Jalil, 57000 Kuala Lumpur, Malaysia.
Tel. No. : +(603) 8996 0023
Email : solution@solution.com.my
Web site : http//www.solution.com.my/
AGENT:
BUATAN MALAYSIA
Equipment for Engineering Education & Research
SOLTEQ