1
]
1
2
w
w
'
c u
t 32
kH
- 1 t f 55 . 0 N (2)
where is taken as 0.7, k = 0.8 for walls restrained at the top and bottom against lateral translations
and against rotation at one or both ends, and k = 1.0 for walls not so restrained against rotation.
Equation (2) applies to walls where H
we
/t
w
25 or L/t
w
25 whichever is less for load-bearing walls.
The minimum allowable thickness is 100mm. The resultant axial load must be in the middle third of
the gross thickness of the wall allowing for a maximum eccentricity of t
w
/6. The walls are required to
have a minimum reinforcement ratio
v
= 0.0015 and
h
= 0.0025. These values can be reduced to
0.0012 and 0.002 respectively if the reinforcing bars are less than 16 mm in diameter or if mesh is
used.
It should be noted that Equations (1) and (2) are limited to H
we
/t 30 and do not include the effects of
reinforcement content, high strength concrete and two-way action.
3. TEST SPECIMENS AND TEST SET UP
3.1 Test Panels
A total of nine wall panels were cast and tested. The dimensions and material properties of the walls
are summarised in Table 1. The panels designated as OWNS and OWHS were tested in one-way
action and panels TWNS and TWHS, in two-way action. Further, NS refers to normal strength
specimens and HS refers to high strength ones.
A local ready-mix concrete supplier batched normal and high strength concrete for all the specimens.
The maximum aggregate size was 10 mm. The high strength concrete mix consisted of silica fume and
super-plasticiser in addition to the normal constituents. No admixtures were used in the normal
strength mix. Three test cylinders for each test panel were cast to obtain the average compressive
strength of concrete.
All wall panels were reinforced with a single F41 mesh, placed centrally in the panel cross-section.
The F41 mesh had a design yield strength of 450MPa and the minimum tensile strength was 500 MPa.
The reinforcement ratios
v
and
h
were 0.0031 for all panels, satisfying the minimum requirements in
the Australian Standard and the ACI code.
Table 1 Reinforced concrete wall panel dimensions and concrete strengths
MODEL H
(mm)
L
(mm)
t
w
(mm)
f'c
(MPa)
H/t
w
OWNS2 1200 1200 40 35.7 30.00
OWNS3 1400 1400 41 51.9 34.15
OWNS4 1600 1600 40 51 40.00
OWHS2 1200 1200 40 78.2 30.00
OWHS3 1400 1400 40 63 35.00
TWNS2 1200 1200 40 37 30.00
TWNS4 1600 1600 40 45.8 40.00
TWHS3 1400 1400 40 60.1 35.00
TWHS4 1600 1600 40 70.2 40.00
3.2 Test Set-Up
An overview of the test set-up is shown in Figure 1. The test frame was designed to support three
independent hydraulic jacks each of 80 tonne capacity. The jacks were required to transmit a
uniformly distributed load across the top through a loading beam at an eccentricity of t
w
/6.
The top and bottom hinged support conditions were each simulated by placing a 23 mm diameter high
strength steel rod on a 50 mm thick steel plate of 150 mm width and varying lengths which
corresponded to the different test panel dimensions. Two 20 mm 20 mm angle sections were
clamped to the thick plate by bolts and the 23 mm diameter rod was welded along the length of the
plate. Details of the simply supported top hinged edge are shown in Figures 2 and 3.
To achieve the hinged support conditions for two-way action, the edges of the panels had to be
effectively stiffened so that rotation about the x-axis was prevented while they were free to rotate
about the y-axis. To achieve this, two parallel flanged channel sections extending along the height of
each of the wall panels were placed on both sides of the panel. They were separated by a square
hollow section as shown in Figure 1.
Dial gauges were used to record the out-of-plane displacements or deflections. They were placed at
quarter and three-quarter heights, and at the centre of the panels as indicated in Figure 1.
3.3 Test Procedure
The walls were loaded in increments up to failure. At each load increment, crack patterns and
deflections were recorded. The latter allowed the load-deflection history to be accurately traced.
Figure 1 Test frame arrangement and side supports
Eccentricity t/6
23 roller
20x20EA
40 mm thickness test panel
150x50 plate
Welding
Figure 2 Details of top hinged edge Figure 3 Details of steel plate
4. RESULTS
Table 2 presents the experimental failure load as well as the peak-load central deflections of the wall
panels. Also given are the experimental axial strength ratio, N
u
/f
c
Lt
w
and the ultimate loads computed
using Equations (1) and (2) due to AS3600 and ACI318 respectively.
It can be seen in the table that the failure load predictions by the two code formulas are poor in that
they either give very conservative results for H/t
w
=30, or zero capacity (i.e. negative values) for those
specimens with H/t
w
>32. Figure 4 depicts this fact further where the code methods predict zero load
capacity for cases beyond H/t
w
= 32. Also shown in Figure 4 are the experimental values of N
u
. All
the nine test panels (6 of which have H/t
w
>32) possessed significant load bearing capacities.
Table 2 and Figure 4 also confirm the beneficial effects of side (two-way) supports the difference in
axial wall strengths between two-way and one-way wall panels. The panels in two-way action were
approximately 3 times stronger than their one-way counterparts. Differences between the normal
strength panels and their high strength counterparts are more difficult to decipher. The high strength
panels, as can be seen in Figure 4, yield slightly lower axial strength ratios, when the slenderness is
held constant.
Table 2 Failure load and deflection of panels
MODEL H/t
w
Deflection
(mm)
Load
(kN)
N
u
f'
c
Lt
w
AS (kN)
Equation (1)
ACI (kN)
Equation (2)
OWNS2 30.00 14.97 247.21 0.144 82.25 114.13
OWNS3 34.15 6.36 426.73 0.143 -237.65 -227.47
OWNS4 40.00 8.97 441.45 0.135 -940.03 -1009.80
OWHS2 30.00 8.85 482.65 0.129 180.15 249.96
OWHS3 35.00 6.61 441.45 0.125 -380.90 -380.76
TWNS2 30.00 9.18 735.75 0.415 85.18 118.19
TWNS4 40.00 7.32 1177.2 0.402 -844.00 -906.64
TWHS3 35.00 10.2 1294.92 0.385 -363.61 -363.47
TWHS4 40.00 6.14 1677.51 0.373 -1293.93 -1389.96
Figure 4 Axial strength ratio versus slenderness ratio
Table 2 also indicates that, in general, deflections are slightly smaller in two-way panels than in the
corresponding one-way specimens. Finally, the crack patterns for four of the panels are recorded in
Figures 5 to 8 for illustrative purposes. The figures show that walls in one-way action are
characterised by horizontal cracking at midspan while those in two-way action feature biaxial
cracking. Note also that TWNS4 and TWHS4 sustained a brittle failure.
5. CONCLUSION
Laboratory strength tests have been carried out on nine reinforced normal and high strength concrete
wall panels in one- and two-way action. Loaded with an eccentricity of t
w
/6, these half-scale
specimens had high slenderness ratios, i.e. with H/t
w
of between 30 and 40.
A comparative study indicates that the design formulas recommended in the Australian Standard
(AS3600-2000) and the ACI code (ACI318-1999) are inadequate in that their strength predictions are
very conservative for the specimens with H/t
w
30; for those with a higher H/t
w
ratio, the formulas
yield negative strength values which indicate zero load-bearing capacity.
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0 10 20 30 40 50
H/tw
N
u
/
(
f
'
c
L
t
w
)
One-way (NSC)
One-way (HSC)
Two-way (NSC)
Two-way (HSC)
AS3600 (Equation 1)
ACI (Equation 2)
The study finds that side supports (or two-way action) greatly increase the strength of the wall panels.
The Standard and code formulas do not account for these beneficial effects.
In view of the significant shortcomings, there is a need to amend these design formulas.
Figure 5 Crack pattern of OWNS2 Figure 6 Crack pattern of OWHS3
Figure 7 Crack pattern of TWNS4 Figure 8 Crack pattern of TWHS4
6. REFERENCES
[1] Standard Australia, Australian Standard 3600, Concrete Structures, Draft, Sydney, 2000, pp.
108-109.
[2] ACI Committee 318, Building Code Requirements for Reinforced Concrete ACI318-99,
American Concrete Institute Detroit, 1999, 111 p.
[3] Swartz, S. E., Rosebraugh, V. H., Berman, M. Y., Buckling test of rectangular concrete panels.
ACI Journal, Vol.71, No. 1, Jan., 974, pp. 33-39.
[4] Saheb, S. M., and Desayi, P., Ultimate Strength of R.C. Wall Panels in One-way in-plane
action, Journal of Structural Engineering, ASCE, Vol.115, No.10, Oct., 1989, pp. 2617-2630.
[5] Saheb, S. M., and Desayi, P., Ultimate Strength of R.C. Wall Panels in Two-way in-plane
action, Journal of Structural Engineering, ASCE, Vol.116, No.5, May., 1990, pp. 1384-1402.
[6] Fragomeni, S., Design of normal and high strength reinforced concrete walls, Ph.D Thesis, The
University of Melbourne, 1996.
[7] Sanjayan, Jay G. and Maheswaran, T., Load Capacity of Slender High-Strength Concrete Walls
with Side Supports, ACI Structural Journal, Vol.96, No. 4, July-August, 1999, pp. 571-576.