Professional Documents
Culture Documents
Follow us on
NANO FIBER ELECTRO SPINNING UNIT NANO FIBER ELECTRO SPINNING TABLE TOP UNIT ELECTRO SPINNING SYRINGE PUMP
SPIN COATING UNIT DIP COATING UNIT DIP COATING UNIT WITH HOT CHAMBER DIP COATING UNIT WITH INFRARED DRYER ANGLE DEPENDENT DIP COATING UNIT
SILAR COATING SYSTEM SILAR COATING SYSTEM WITH STIRRER SILAR COATING SYSTEM WITH MAGNETIC STIRRER
SILAR COATING SYSTEM WITH MAGNETIC STIRRER & ULTRASONIC BATH STAND SPRAY PYROLYSIS EQUIPMENT SPRAY PYROLYSIS TABLE TOP MODEL
FLAME ASSISTED SPRAY PYROLYSIS EQUIPMENT ION EXCHANGER BENCH TOP RUBBING MACHINE SYRINGE PUMP
PERISTALTIC PUMP DIGITAL MAGNETIC STIRRER DIGITAL MAGNETIC STIRRER WITH HOT PLATE
I I
I I I I
I I
I I
I I I
I I
HOLMARC
OPTO-MECHATRONI CS PVT. LTD
TM
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd
For more products and information
please log on to www.holmarc.com
EQUIPMENTS LAB
For Research & Manufacturing
PRODUCT LINE 2014-15
RESERCH LAB EQUIPMENTS
for Material Science, Nano & Bio Technology
HOLMARC OPTO MECHATRONICS PVT LTD
TM
HOLMARC
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd
For more products and information
please log on to www.holmarc.com
PRODUCTS 2014-15
RESERCH LAB EQUIPMENTS
for Material Science, Nano & Bio Technology
HOLMARC
OPTO-MECHATRONI CS PVT. LTD
TM
Holmarc Opto-Mechatronics P Ltd has been organized as a provider of
engineering tools for scientific research. Our company is equipped to meet most
challenging and demanding requirements of scientific community with our
manufacturing and development capabilities in optics, mechanics, electronics &
software. At Holmarc, experienced engineers, designers & technicians work hand
inhandtodeliver state of the art engineeringsolutions toour clients.
All of us at Holmarc stay tuned to absorb changes in technology as fast as
possible. We deliberately keep our technical skills as well as manufacturing
infrastructure flexible and maintain a dynamic work culture throughout our
operations. We have distributors and collaborators in all parts of the world and are
well equipped to serve world scientific community. We welcome queries
irrespective of geographical andpolitical boundaries.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Nano Fiber
Electrospinning Unit
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd
Model : HO-NFES-040
01
RLE
Holmarcs HO-NFES-040 model electrospinning equipment is a complete
unit for Nanofiber electrospinning. Its user friendly software, task oriented
design, ease of operation and competitive pricing are certain features that
place our equipment ahead of other products available in the market.
Holmarcs HO-SPLF4 model syringe pump render a smooth and
uninterrupted flow enabling uniform spinning. HMPSKV30 model high
voltage power supply delivers 0-30 KV output voltage range with a
maximum current capacity of 0.5 mA. A stationary target, an XY moving
target and Rotating mandrels of six different diameters are supplied along
withthe unit.
HO-FH-01 model fume hoodprovides an enclosedatmosphere
with transparent side walls to monitor the electro spinning process. The
inbuilt heater can raise the process temperature up to 60C. A common
electronic control unit is integrated within the hood. The hood also has
features like exhaust fan, granite work surface and optional features like
high bright halogen lighting, duct of custom dimension to be connected to
anexhaust duct available onsite etc
High Voltage Power Supply Rotating Mandrel Stationary Target XY Target
Key Features
User friendly software enables PC interfacing that helps
the regulation and control of various features like Rotating
mandrel speed, Spin Duration, Syringe pump flow rate,
XY target movement etc.
Rotating Mandrel targets of varying diameters, Stationary
target and Reciprocating XY target provided with the system.
System hood has features like Exhaust fan, halogen lighting
and transparent door for monitoring electrospinning process.
SSPlate withgroundingfacility
Diamention: 320 mmx 100 mmx 2 mm
Fume Hood
Standalone unit with in-built power supply and wiring for the heater,
lighting and exhaust
Transparent glass windows onthree sides for easily monitoringthe
electrospinningprocess
Foot print: 1200mm x 850mm x 1750 mm
Construction Material: Stainless Steel, Aluminium & Glass
Epoxy coated for electrical insulation
Ambient to 60degree Celsius temperature control
Exhaust fan ventilation at the top of the hood which can be connected to
an exhaust outlet available at the customer facility.
PCInterfaceSoftware
Centralized software control of almost all of the electrospinning parameters
Single software interface for syringe pump, XYtarget androtatingdrum
collector
All of the process parameters canbe savedas user programandretrieved
for analysis or rerun
S
P
E
C
I
F
I
C
A
T
I
O
N
S
S
P
E
C
I
F
I
C
A
T
I
O
N
S
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
XYTarget
SSPlate withgroundingfacility
Diamension320 mmx 100 mmx 2 mm
Fume Hood
Standalone unit with in-built power supply and wiring for the heater,
lighting and exhaust
Transparent glass windows onfour sides for easily monitoringthe
electrospinningprocess
Foot print: 1000mm x 800mm x 1260 mm
Construction Material: Stainless Steel, Aluminium & Glass
Epoxy coated for electrical insulation
Hazard lamp to indicate that HV power supply is on
Exhaust fan ventilation at the top of the hood which can be connected to
an exhaust outlet available at the customer facility.
Syringe Pump
Features :
Syringe : Standard off the shelf syringes,
10 to 60 ml, any manufacturer
Flow rate range : 2.757 l / hr to 19.6 ml / min
Temperature control up to 60C (in select models)
Dispensing accuracy: +/- 1%
Operates in stand alone or through a personal computer
Microprocessor controlled mechanism
Front panel with keyboard and display for programming
Silent and smooth operation
Compatible with glass, plastic and SS syringes
Model No:
HO-SPLF-ES 1
HO-SPLF-ES 1H
HO-SPLF-ES 2
HO-SPLF-ES 2H
HO-SPLF-ES 4
HO-SPLF-ES 4H
HO-SPLF-ES 10
HO-SPLF-ES 10H
HO-SPLF-ES 2D
HO-SPLF-ES 2DH
Item
Single Syringe Pump
Single Syringe Pump with temperature control
Dual Syringe Pump
Dual Syringe Pump with temperature control
Four Syringe Pump
Four Syringe Pump with temperature control
Ten Syringe Pump
Ten Syringe Pump with temperature control
Independently controlled Dual Syringe Pump
Independently controlled Dual Syringe Pump
with temperature control
Temperature control( room temp. )
60 degree
60 degree
60 degree
60 degree
60 degree
No. of Syringes
One
One
Two
Two
Four
Four
Ten
Ten
Two
Two
Holmarc manufactures syringe pumps in various models for single syringes, two syringes , four syringes and ten syringes as described in the
chart below. In our dual syringe model no: SPLF-ES 2D, two syringes can operate independently with different flow parameters. In SPLF-ES H
series pumps, temperature of syringes is controllable upto60 degree fromambient.
Manual Micro Syringe Pump
Key Features:
Compact and attractive design
User friendly keyboard & LCD monitor
PC controllable
User friendly software
Infrared dryer for precise substrate heating
Specifications
Actuator
Drive mechanism
Speed control
Power input
PC connectivity
Stroke length max.
Drawing speed min.
Drawing speed max.
Program memory
Dimension
Max. Power Consumption
Max Temperature
Max Substrate size
Servo motor
Lead screw
Available
230V, 50Hz
Serial port (RS 232)
150 mm
2 micron/sec
9000 micron/sec
8 programs
630 x 368 x 420 mm
600 watts
200 Celsius
75 mm
Watch Video Demo @ You
www.you .com/holmarcproducts tube
PID Controller is used for optimum heating of the
substrate. Apart from other sensors that sense the
temperature of the heating chamber as a whole, the
infrared sensor gives feedback of the temperature
attainedby the substrate by monitoringits emissivity.
Dip coating unit with infrared dryer is mainly used in
physics, chemistry and biotechnology labs and
corresponding research activities. Our device is
designed and manufactured as a table top unit with
electronics and servo motor aptly positioned making it
compact and best suited for laboratory and research
activities.
N
e
w
E-mail:mail@holmarc.com
Sales@holmarc.com
www.holmarc.com
Visit us at
PH : +91 484 2540075
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd 07
RLE
HOLMARC OPTO MECHATRONICS PVT LTD
TM
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
Angle Dependent Dip Coating Unit
Model : HO-TH-ADDC1
Holmarc Angle Dependent Dip Coating unit enables nano layer
coating of substrates by dipping them in beakers containing
coating solution. The dipping angle can be varied from 0 to 45
degree depending upon the requirement. There are 4 beaker
holders provided for coating 4 different substrates. The dipping
speed, dip duration, withdrawal speed and dry duration can be
variedfor eachbeaker independently
Basic principle of ADDC: The substrate is drawn out of the coating
solution under a well defined angle of inclination. Both surfaces are
coated simultaneously resulting in different film thickness on front
andback side.
One of the advantage of ADDC is the reduced number of layers or
coatingsteps toobtainthe desiredthinfilmproperties.
Fig. Dip coating machine with variable coating angle
It can be customized to suit specific applications.
We welcome such requests from all our customers.
Please discuss your application needs with us.
Specifications
Actuator
Drive mechanism
Speed control
Power input
PC connectivity
Stroke length max.
Drawing speed min.
Drawing speed max.
Dimensions (appx.)
Program memory
max. power consumption
Servo motor
Lead screw
Available
230V, 50Hz
Serial port (RS 232)
75 mm
2 micron/sec
9000 micron/sec
570 x 300 x 475 mm
8 Programs
800 Watts
Need customization?
HOLMARC's experienced support
engineers will be glad to help you
.
Call us at or
send us a mail to
+91 484 2540075
sales@holmarc.com
mail@holmarc.com
N
e
w
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd
HOLMARC OPTO MECHATRONICS PVT LTD
08
RLE
TM
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
SILAR Coating System
Model : HO-TH-03
Holmarcs SILAR Coating System has been designed to automate the
entire process to avoid operator fatigue and errors associated with it. In
manual SILAR process, the operator has to performhundreds of repetitive
dipping into the solution and water. It is very difficult to control dip duration
andnumber of dips inamanual process whichcanlast hours.
In this system, thin film is deposited on glass substrate following a
chemical technique called Successive Ion Layer Adsorption and Reaction
(SILAR). The process involves multiple dipping of the substrate in a given
solution and deionized water, temperature of both can vary from case to
case.
In the automated unit, the operator need just to clamp the subtract into the
holder andprogramthe controller withrequireddipcycles andduration.
SOFTWARE
Vertical Movement
360
0
Sample Holder
Rotation
This device can be customized as per
requirement. Please discuss your application with
our engineers.
Specifications
Actuator
Drive mechanism
Dip duration
Number of dips
Operating temperature
Power input
PC connectivity
Stroke length
Stepper motor
Lead screw
0 - 99 sec / min / hr
1 - 999
Ambient to 80
230V, 50Hz
Serial port (RS 232)
75mm
This device can be customized as per requirement. Holmarc has
developed models where a controlled heater is used for keeping each
beaker at specifiedtemperatureindependently.
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd 09
RLE
HOLMARC OPTO MECHATRONICS PVT LTD
TM
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd
HOLMARC OPTO MECHATRONICS PVT LTD
10
RLE
TM
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
Model : HO-TH-03A
This model HO-TH-03Ahas a motorizedsubstrate holder which can be used
to stir the solution. By rotating the substrate along with the holder at desired
speed, the solution can be kept stirred during the dipping process. The
rotation speed is programmable from 1 - 200 rpm. The dipping speed, dip
duration, retrieval speed and dry duration can be set for each beaker. Each
hot plate can be set at different temperatures. The temperature can be set
upto
Holmarcs SILARCoating Systemhas been designed to automate the entire
process to avoid operator fatigue and errors associated with it. In manual
SILAR process, the operator has to perform hundreds of repetitive dipping
into the solution and water. It is very difficult to control dip duration and
number of dips in a manual process which can last hours. In the automated
unit, the operator need just to clamp the substrate into the holder and
program the controller with required dip cycles and duration. When the
process is over, abuzzer will intimate the operator.
In this technique thin film is deposited on glass substrate following a
chemical technique called successive ion layer adsorption and reaction
(SILAR). The technique involves multiple dipping of the substrate in a given
solution and deionized water, temperature of both can vary from case to
350Cfromambient.
This device can be
customized as per
requirement. Please
d i s c u s s y o u r
application with our
engineers.
Specifications
Actuator
Drive mechanism
Dip duration
Number of dips
Hot plate temperature
Stirrer speed
PC connectivity
Stroke length
Power input
Stepper motor
Lead screw
0 - 99 seconds / minutes / hours
1 - 999
Ambient to 350C
1 - 200 rpm
Serial port (RS 232)
75mm
230V, 50Hz
All Holmarc Instruments and their
accessories are warranted by
HOLMARC for a period of ONE
YEAR from the date of original
purchase. Holmarc will repair or
replace a product, or part thereof,
found by Holmarc to be defective,
provided the defective part is
returned to Holmarc, with proof of
purchase. We guarantee effective
services delivered in a timely
manner.
Watch Video Demo @ You
www.you .com/holmarcproducts tube
SILAR Coating System With Stirrer
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
N
e
w
In the Model HO-TH-03B the solution containing beakers are kept on hot plates with magnetic stirrers. The rotation
speed of the stirrers can be controlled from 1 - 1000 rpm. The dipping speed, dip duration, retrieval speed and dry
duration can be set for each beaker. Each hot plate can be set at different temperatures. The temperature can be set
upto200Cfromambient
Silar Coating System With
Magnetic Stirrer
Model : HO-TH-03B
Holmarcs SILAR Coating System has been designed to automate the
entire process to avoid operator fatigue and errors associated with it. In
manual SILARprocess, the operator has to performhundreds of repetitive
dipping into the solution and water. It is very difficult to control dip duration
and number of dips in a manual process which can last hours. In the
automated unit, the operator need just to clamp the substrate into the
holder andprogramthe controller withrequireddipcycles andduration.
In this technique thin film is deposited on glass substrate following a
chemical technique called successive ion
layer adsorption and reaction (SILAR). The
technique involves multiple dipping of the
substrate in a given solution and deionized
water, temperature of both can vary from
case tocase.
Specifications :
Actuator
Drive mechanism
Dip duration
Number of dips
Hot plate temperature
Stirrer speed
PC connectivity
Stroke length
Power input
Stepper motor
Lead screw
0 - 99 seconds / minutes / hours
1 - 999
Ambient to 200C
1 -1000 rpm
Serial port (RS 232)
75mm
230V, 50Hz
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd 11
RLE
HOLMARC OPTO MECHATRONICS PVT LTD
TM
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
N
e
w
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd
HOLMARC OPTO MECHATRONICS PVT LTD
12
RLE
TM
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
Silar Coating System With
Magnetic Stirrer and Ultrasonic
Bath Stand
Model : HO-TH-03C
Holmarcs SILAR Coating System has been designed to automate the
entire process to avoid operator fatigue and errors associated with it. In
manual SILARprocess, the operator has to performhundreds of repetitive
dipping into the solution and water. It is very difficult to control dip duration
and number of dips in amanual process which can last hours. In the
automated unit, the operator need just to
clamp the substrate into the holder and
program the controller with required dip
cycles andduration.
In this technique thin film is deposited on
glass substrate following a chemical
technique called successive ion layer
adsorption and reaction (SILAR). The
technique involves multiple dipping of the
substrate in a given solution anddeionized
water, temperature of both can vary from
case tocase.
This model has a magnetic stirrers which can be used to stir the solution. The rotation speed can be
controlledfrom1 - 1000 rpm. The dippingspeed, dipduration, retrieval speedanddry duration can be set
for each beaker. Each hot plate can be set at different temperatures. The temperature can be set up to
200Cfromambient. There is afifthstandinthis model for keepinganultrasonic bath.
Specifications :
Actuator
Drive mechanism
Dip duration
Number of dips
Hot plate temperature
Stirrer speed
PC connectivity
Stroke length
Power input
Stepper motor
Lead screw
0 - 99 seconds / minutes / hours
1 - 999
Ambient to 200C
1 -1000 rpm
Serial port (RS 232)
75mm
230V, 50Hz
N
e
w
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
Cleanliness
Surface area
Surface topography or profile
Temperature ( thermal energy )
Time ( reaction rates & cooling rates etc.)
Speed
Physical & chemical properties
Physical & chemical reactions
Factors affecting bonding &
subsequent build up of the coating:
Spray Pyrolysis Equipment
Holmarcs Spray Pyrolysis system has been designed for research
laboratories in thin films, especially for solar cell development. The system
automates various fatigue and error creating processes involved in the
technique when performed manually. Moreover, ergonomically designed
chamber provides clean and healthy atmosphere suitable for modern lab
conditions.
Parameters like dispensing rate of the solution and speed of spray head
movement which are difficult to control manually are controlled precisely
by PC based automation. A positive displacement pump controlled by
stepper motor and microprocessor is used to dispense solution as per
requirement. The spray head movement is also controlled by stepper
motor driven linear stages in X and Y direction. The temperature of the
substrate heater plate is controlled independently through a dedicated
controller.
A desk top computer with windows OS is used to control the operations
through serial port. Our dedicated software for spray pyrolysis systemcan
as well be used for documenting the relevant parameters used for sample
preparationlike temperature, air pressure, duration, etc.
Watch Video Demo @ You www.you .com/holmarcproducts tube
Spray pyrolysis is a process in
which a thin film is deposited
by spraying a solution on a
heated surface, where the
constituent react to form a
chemical compound. The
chemi cal r eact ant s ar e
sel ect ed such t hat t he
products other than the
desired compound are volatile
at t he t emper at ur e of
deposition. The process is
particularly useful for the
deposition of oxides and has
l ong been a producti on
met hod f or appl yi ng a
t r a n s pa r e n t e l e c t r i c a l
conductor of Tin oxide (SnO2)
or Stannic oxide toglass.
Specifications
Actuator
Dispensing unit capacity
Dispensing rate
Sprayer
Drive speed X axis (min-max)
Drive speed Y axis (min-max)
Sprayer traverse
Substrate base plate
Dimension
Max. temperature
Power input
PC connectivity
Stepper motor
50ml & 250ml
1 - 10ml/min.
10 - 800mm/sec
1 - 12mm/sec
X - Y 200mm max.
150 x 150mm
500C
230V, 50Hz
Serial port (RS 232)
Model : HO-TH-04
New
Ultrasonic spray head
available !!!
Syringe pump is preferable to the
glass dispenser for solutions
which should be sprayed at lower
flow rates (<1ml / min). It works
with very lowvolume of solution as
the syringe is directly connected
to the spray nozzle, avoiding the
use of lengthy tubes which should
be filled first before the solution
canreachthe nozzle.
The standard spray head which
uses a compressed air atomization
nozzle can be replaced with the
ultrasonic spray head which uses
an ultrasonic atomizer nozzle. It
breaks the solution by vibrating its
nozzle at an ultrasonic frequency
(Typically 40 kHz), producing a fine
spray of droplets of 50 micron
average size.
Syringe Pump Ultrasonic Spray Head
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd 13
RLE
HOLMARC OPTO MECHATRONICS PVT LTD
TM
Spray Pyrolysis Equipment
Table Top Model
HOLMARCs Spary Pyrolisis Equipment Model :HO-TH-04 BT is
more compact and sleek model that does not take too much space in your
laboratory.It can be placed in any available platform. Even though Smaller in
size it performs all the functions andoperations of the standardmodel.
Holmarcs Spray Pyrolysis System has been designed for research
laboratories in thin films, especially for solar cell development. The system
automates various fatigue and error creating processes involved in the
technique when performed manually. Moreover, ergonomically designed
chamber provides clean and healthy atmosphere suitable for modern lab
conditions.
Parameters like dispensing rate of the solution and speed of spray head
movement which are difficult to control manually are controlled precisely by
PCbased automation. A positive displacement pump controlled by stepper
motor and microprocessor is used to dispense solution as per requirement.
The spray head movement is also controlled by stepper motor driven linear
stages in X and Y direction. The temperature of the substrate heater plate is
controlledindependently throughadedicatedcontroller.
(Table Top)
Specifications
Actuator
Dispensing unit capacity
Dispensing rate
Sprayer
Drive speed X axis (min-max)
Drive speed Y axis (min-max)
Sprayer traverse
Substrate base plate
Dimension
Max. temperature
Power input
PC connectivity
Stepper motor
50ml & 250ml
1 - 10ml/min.
10 - 800mm/sec
1 - 12mm/sec
X - Y 200mm max.
150 x 150mm
500C
230V, 50Hz
Serial port (RS 232)
Syringe pump is preferable to the glass dispenser
for solutions which should be sprayed at lower
flow rates (<1ml / min). It works with very low
volume of solution as the syringe is directly
connectedtothe spray nozzle, avoidingthe use of
lengthy tubes which should be filled first before
the solutioncanreachthe nozzle
The standard spray head which uses a
compressed air atomization nozzle can be
replaced with the ultrasonic spray head which
uses an ultrasonic atomizer nozzle. It breaks the
solution by vibrating its nozzle at an ultrasonic
frequency (Typically 40 kHz), producing a fine
spray of droplets of 50 micronaverage size.
Syringe Pump
Ultrasonic Spray Head
Spray pyrolysis is a process in which a thin film is
depositedby sprayinga solution on a heatedsurface,
where the constituent react to form a chemical
compound. The chemical reactants are selected
such that the products other than the desired
compound are volatile at the temperature of
deposition. The process is particularly useful for the
deposition of oxides and has long been a production
method for applying a transparent electrical
conductor of Tin oxide (SnO2) or Stannic oxide to
glass.
E-mail:mail@holmarc.com
Sales@holmarc.com
www.holmarc.com
Visit us at
PH : +91 484 2540075
Model : HO-TH-04BT
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
Adesk topcomputer with windows OS
is used to control the operations
through serial port. Our dedicated
software for spray pyrolysis system
can as well be used for documenting
the relevant parameters used for
sample preparation like temperature,
air pressure, duration, etc.
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd
HOLMARC OPTO MECHATRONICS PVT LTD
14
RLE
TM
N
e
w
All products are manufactured and marketed by Holmarc Opto-Mechatronics Pvt. Ltd 15
RLE
HOLMARC OPTO MECHATRONICS PVT LTD
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
Flame Assisted
Spray Pyrolysis Equipment
Model : HO-TH-04FA
Cleanliness
Surface area
Surface topography or profile
Temperature ( thermal energy )
Time ( reaction rates & cooling
rates etc.)
Speed
Physical & chemical properties
Factors affecting bonding &
subsequent build up of the
coating:
Watch Video Demo @ You www.you .com/holmarcproducts tube
Specifications
Actuator
Dispensing unit capacity
Dispensing rate
Drive speed X axis (min-max)
Drive speed Y axis (min-max)
Sprayer traverse
Dimension
Max. temperature
Power input
PC connectivity
Sprayer
Substrate base plate
Stepper motor
50ml & 250ml
1 - 10ml/min.
5 - 20mm/sec
2 - 12mm/sec
X - Y 100mm max.
150 x 150mm
500C
230V, 50Hz
Serial port (RS 232)
TM
N
e
w
Holmarc's Flame Assisted Spray Pyrolysis Equipment Model : HO-TH-
04FA has been developed for research in surface quality improvement of
metallic alloys and ceramics. In this technique, solution is sprayed on to a
heated substrate through an oxygen-acetylene flame. The equipment is
fitted with accessories required for controlling the flame during the
process. The solution is spayed using a positive displacement pump and
compressed air through a mixing chamber and nozzle. The substrate is
placed on a hot plate, temperature of which can be set at the desired level
through a dedicatedcontroller. The hot plate is mountedon a motorizedXY
platformto move the substrates during the coating process in the required
sequence sothat uniformcoatingis achieved.
Flow rate of the solution and motion sequence of the substrate are
controlled through a personal computer. The flame is initiated and set at
the required intensity level manually using the control accessories fitted
with the equipment. As the solution is sprayed with the help of
compressed air, the equipment can be used for spray pyrolysis without
flame as well. `Combination of pyrolysis thin films with and without flame
canalsobe producedonthe same substrates insuccessive operations.
Spray pyrolysis is a process in which a thin filmis depositedby atomizingandsprayinga
solution on a heated surface, where the constituent reacts to form a chemical
compound. In flame assisted spray pyrolysis, this spray is heated by a flame produced
by anoxy-acetylene gas mixture, before beingdepositedontothe substrate.
The chemical reactants are selected such that products other than the desired
compound are volatile at the temperature of deposition. The process is generally useful
for the deposition of oxides on to metal and ceramic substrates and particularly suitable
for the deposition of Al2O3, ZnOand metastable solid solutions of ZnO-MgOand ZrO2-
Y2O3 onamorphous silicaandNickel basedsuper alloys suchas Nimonic-90.
Ion Exchanger
Model : HO-TH-06
Holmarcs Ion exchanger, is a dedicated device for forming thin films by
dipping the substrate in melt kept in hot chamber. Temperature of the
heater can be controlled and fixed up to 400C from ambient. Speed,
duration, etc. are maintainedaccurately by computer control. Movements
are achievedby aprecisionservo/ stepper motor controlledlinear stage.
The systemhas a user friendly front panel withkey boardandLCDdisplay.
It can as well be controlled through a computer. Dip duration, dip speed,
withdrawal speedetc. are programmable features.
Servo motor (Optional) is used as actuator for vibration free dipping and
withdrawal. The device is designedandmanufactured as table top device
with entire electronics and servo motor housed in a compact unit. Height
of the substrate holder can be adjusted with respect to the level of the
solutionduringthe experiment.
Specifications
Actuator
Drive mechanism
Speed control
Power input
PC connectivity
Stroke length max
Drawing speed min.
Drawing speed max.
Stepper motor (Servo - Optional)
Precision rolled ball screw
Available
230V, 50Hz
Serial port (RS 232)
150mm
2 micron/sec
9000 micron/sec
Substrate holder :
a) Motorized linear stage for substrate movement.
b) Actuated by stepper motor.
c) Travel : 80mm
d) Minimum speed : 0.1mm/sec
Maximum speed : 10mm/sec
e) Maximum size of movable substrate plate : 100mm x 100mm
f) Substrate fixed on a rotation stage which can be rotated from
0 to 180 degrees.
Rubbing wheel actuator : Brushless DC motor with speed control
Maximum speed : 3000rpm
Minimum speed : 10 rpm
Display of speed on LCD screen
Speed control of the spindle by input voltage variation by a knob
Input: 230 VAC
The System can be used in standalone mode as well as in PC mode
Weight of the System: 25 Kgs (approx.)
Specification
Programmable Features
:
Movement range for the substrate
Speed of movement (substrate stage)
No. of repetitions / Duration of operation
Bench Top Rubbing Mechine
Model : HO-IAD-BTR-01
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
W
e
c
a
n
p
r
o
v
i
d
e
c
l
i
e
n
t
d
e
s
i
g
n
e
d
i
n
s
t
r
u
m
e
n
t
s
o
n
s
p
e
c
i
a
l
o
r
d
e
r
.
F
o
r
m
o
r
e
d
e
t
a
i
l
p
l
e
a
s
e
c
o
n
t
a
c
t
u
s
H
O
L
M
A
R
C
R
E
S
E
A
R
C
H
L
A
B
E
Q
U
I
P
M
E
N
T
S
2
0
1
4
-
1
5
P
R
O
D
U
C
T
L
I
N
E
Syringe Pump / Infusion Pump
Model : HO-SPLF-2D/SPLF 4
Holmarc's SPLF series syringe pumps are versatile and cost effective
products for precise dispensing of fluids in laboratory experiments. The
pump can operate with standard off the shelf syringes in plastic, glass and
stainless steel. The dispensing rates/flowrates possible with the device are
very wide in range andcan vary from2.8 micro-l/hr to19ml/min. The unit has
built in electronics with keyboard and display for programming the
operational attributes to work in standalone mode. Computer interfacing is
also possible when ever required with RS 232C serial integrated into the
control electronics of the system.
Holmarc manufactures syringe pumps in various models for single
syringes, two syringes , four syringes and ten syringes as described in the
chart below. In our dual syringe model no: SPLF-ES 2D, two syringes can
operate independently with different flow parameters. In SPLF-ES H series
pumps, temperature of syringes is controllable up to 60 degree from
ambient.
Specification
Features :
Syringe : Standard of the shelf syringes,
10 to 60 ml, any manufacturer
Flow rate range : 2.757 l / hr to 19.6 ml / min
Temperature control up to 60C (in select models)
Dispensing accuracy: +/- 1%
Operates in stand alone or through a personal computer
Microprocessor controlled mechanism
Front panel with keyboard and display for programming
Silent and smooth operation
Compatible with glass, plastic and SS syringes
Model
HO-SPLF-ES 1
HO-SPLF-ES 1H
HO-SPLF-ES 2
HO-SPLF-ES 2H
HO-SPLF-ES 4
HO-SPLF-ES 4H
HO-SPLF-ES 10
HO-SPLF-ES 10H
HO-SPLF-ES 2D
HO-SPLF-ES 2DH
Item
Single Syringe Pump
Single Syringe Pump with temperature control
Dual Syringe Pump
Dual Syringe Pump with temperature control
Four Syringe Pump
Four Syringe Pump with temperature control
Ten Syringe Pump
Ten Syringe Pump with temperature control
Independently controlled Dual Syringe Pump
Independently controlled Dual Syringe Pump
with temperature control
Temperature control
up to 60 degree
up to 60 degree
up to 60 degree
up to 60 degree
up to 60 degree
No. of Syringes
One
One
Two
Two
Four
Four
Ten
Ten
Two
Two
Manual Micro Syringe Pump
8 Nozzle Dispensing
ccurate dispense channels
Low dead volume
Fast dispenses
Adjustable dispensing range
Removable tubings
Small footprint
Configurable for different well plates
Microprocessor-controlled syringe pump
No recalibration required
Minimum dispense volume of 1 L
Dispense precision: 5% CV
N
e
w
Fig.
Custom developed, Designed for
fluorescence and chemiluminescence
imaging.
Biochip Imager
CUSTOM
Product customization has been a core service of HOLMARC throughout
our 20 year history. Infrastructure and capabilities in mechanics and optics
enable us to provide complete in-house services. We can modify a
standard product or engineer a complete solution to meet any specific
application requirements. HOLMARC has the unique capability to
customize standard products for OEM and scientific applications. In
addition to new product development, we actively pursue continuous
improvement of our existingproducts.
Our experienced engineering, manufacturing and inspection teams are
dedicated to produce quality components. We can assist in design and
development of components as well as complete assemblies. We are
dedicated to meet our customer needs by leveraging our years of
experience inoptics, mechanics andcontrol electronics.
We have a state of the art laboratory for quality control and inspection. We
have established a fail safe inspection procedure to make sure of the
quality standardof our products before shipment.
QualityControl
Complete Solution for Custom Design and Manufacturing
E-mail Contacts
mail@holmarc.com
sales@holmarc.com
Phone Contacts
Tel: 91-484-2540075 (Off)
Fax: 91-484-2540882
H
O
L
M
A
R
C
HOLMARCis unique in its ability to design, prototype,
and manufacture under one roof . We have well-developed
optic and mechanical fabrication facilities and thin film
coating unit. Contact us for assistance with your
manufacturingneeds.
I
n
t
e
g
r
a
t
e
d
E
n
g
i
n
e
e
r
i
n
g
Product ...? customization
TM
FOR RESEARCH & INDUSTRY
HIGH QUALITY PRECISION
OPTICS
visit us @
www.holmarc.com
Holmarc Opto-Mechatronics P Ltd. has been incorporated in the year
1993 for the manufacture of precision manipulators. Over the years, we
have addeda lot many products andcapabilities in optics, mechanics and
electronics as youwill findout fromthe list givenbelow.
We have grown to be company of 165 people in 2013 and still growing in
strength, products and infrastructure. We have machining, finishing,
assembly and testing facilities for manufacturing fine mechanics. Our
technicians have gained world class expertise in precision engineering
andfine mechanics.
Our optics production unit includes roughing, grinding, polishing, coating
(PVD) and testing facilities operated by well experienced technicians. We
have an advanced holographic lab for production of commercial
holograms as well as holographic gratings.
Our electronics and software engineers are experienced and dedicated
for motion control and opto-electronics integration. We are proud of
having a strong design team in mechanics and optics with inexhaustible
appetite for newideas andinnovations.
We have excellent quality control system. Right from ordering of new
material todespatchof finishedgoods, effective quality control is applied.
OFFICE & FACTORY ADDRESS
B.7, H.M.T. INDUSTRIAL ESTATE,
H.M.T. P.O, KALAMASSERY,
KOCHI, KERALA,INDIA
Ph.No. +91-484 2540075 Fax : +91-484 2540882
HOLMARC OPTO-MECHATRONICS PVT. LTD
www.holmarc.com
visit us @
E-mail: sales@holmarc.com / mail@holmarc.com
Follow us on
SpectrA
INSTRUMENTS
Wide range of wavelengths and resolution
HOLMARC
HOLMARC Optics
A Division of Holmarc Opto-Mechatronics Pvt. Ltd
IMAGE
A N A L Y Z E R P R O
HOLMARC
TM
HOLMARC
TM
O
P
T
O
-
M
E
C
H
A
T R O N I C S P V T . L
T
D
lAB
HOLMARC
P H Y S I C S
I N S T R U M E N T S
B
e
c
a
u
s
e
o
f
c
o
n
t
i
n
u
o
u
s
p
r
o
d
u
c
t
i
m
p
r
o
v
e
m
e
n
t
,
t
h
e
v
a
r
i
o
u
s
d
a
t
a
l
i
s
t
e
d
a
r
e
s
u
b
j
e
c
t
t
o
c
h
a
n
g
e
w
i
t
h
o
u
t
n
o
t
i
c
e
.
For more products and information,
Designed @ HOLMARC Design LAB
TM
Cochin, FEB 2014
All Products are manufactured and marketed by
HOLMARC Opto-Mechatronics Pvt. Ltd
TM
C
O
M
P
A
N
Y
P
R
O
F
I
L
E