The document describes the WT500-series digital transmitters used for wind, temperature, and humidity sensors. The transmitters sample sensor data at up to 5 Hz, average the data, and transmit it digitally up to 10 km via an onboard RS485 port. They operate from 12-50VDC and have a temperature range of -40°C to +60°C. Configuration and data collection is done through onboard serial communication or by uploading configuration files.
The document describes the WT500-series digital transmitters used for wind, temperature, and humidity sensors. The transmitters sample sensor data at up to 5 Hz, average the data, and transmit it digitally up to 10 km via an onboard RS485 port. They operate from 12-50VDC and have a temperature range of -40°C to +60°C. Configuration and data collection is done through onboard serial communication or by uploading configuration files.
The document describes the WT500-series digital transmitters used for wind, temperature, and humidity sensors. The transmitters sample sensor data at up to 5 Hz, average the data, and transmit it digitally up to 10 km via an onboard RS485 port. They operate from 12-50VDC and have a temperature range of -40°C to +60°C. Configuration and data collection is done through onboard serial communication or by uploading configuration files.
Digital Transmitters for W,T,U Optimized for Various Sensors
Quality Data
On-line Configurable
Easy to Use & Install K076en 1999-04 Measurements - WS/WD 4 Hz sampling, 0.25-5 s average - T/U 1 Hz sampling, 1 min average I/O - on-board RS485 (2 - and 4 wire) - optional RS232, isolated RS485, modem Input operating power 12.. 50 VDC, 0.1 W nominal Temperature range - operating / storage - 40...+ 60 C / -50..+70 C Length / Clamp 800 mm / 60 mm (max.) (WT521) Material - cross arm grey anodized aluminum - junction box grey painted aluminum Weight 0.4, 0.7 and 1.6 kg MTBF (Gf) 47.41 / M hours EMC EN 50081-1, EN 50082-1 Technical Data K076en 1999-04 Why Wind Transmitter is needed Analog line up to 100m Digital line up to 10 km K076en 1999-04 WT501 96.6 64 46.4 - I N L 1 3 C / A G N D - I N 2 3 L 2 2 2 4 2 5 O U T + I N C / A G N D E 2 0 H 2 1 1 9 2 7 2 6 2 8 A 1 A 2 M O D M O D A 4 A 3 A 5 M O D M O D M O D - I N O U T + I N L 1 8 E 1 6 H 1 7 2 9 3 1 3 0 G N D F 1 5 1 4 I N 3 2 3 4 3 3 G L D I R G 1 D I R D I R G 0 G 2 G 4 G 3 D I R D I R D I R I N F 1 0 + I N O U T H 1 2 E 1 1 3 5 3 7 3 6 I / O S G N D 9 S D + 8 3 8 3 9 G 5 O U T G N D D I R D + 2 C H E A T H E A T - I N I / O + I N D A T A 6 S D - 7 5 D A T A 4 0 4 1 4 2 H E A T R E T - R E T P W R 4 3 2 H E A T 4 3 4 4 I N 4 5 I N O U T F + F G N D 1 C + I N B A T H E A T H E A T + I N 1 P W R 4 6 G N D B A T Power Supply On board RS-interface WMS- Wind Sensor HMP45 T/U probe pt100- probe Communication Module I/O WAV- Wind Vane WAA- Anemometer Battery Back up K076en 1999-04 WT511 127.1 38 66 110 81.5 19.1 120.4 57.6 72.6 K076en 1999-04 WT521 887 145 148 K076en 1999-04 Installation 60 102 K076en 1999-04 Jumpers Modem line supply: X4/1-2 X5/1-2 X16 open Heating options: Series (40 VDC) X6/2-3 Parallel (20 VDC) X6/1-2 & X6/3-4 K076en 1999-04 WAA/WAV151 sensor heating options WT 501 WT 501 Series Parallel +40V +20V Jumpers X6/2-3 Jumpers X6/1-2&3-4 K076en 1999-04 WT501 Powering options Local powering Powering via modem line WHP151 20VDC MODEM LINE 115/230VDC 24VDC Jumpers: X4/1-2 X5/1-2 X16 open MODEM LINE + 48VDC SUPPLY VOLTAGE 24VDC WIND50 WIND50 WT501 WT501 Jumpers: X16/1-2 X4 open X5 open K076en 1999-04 Automatic message mode Main system Output messages sent automatically by the transmitter at specified intervals Only one transmitter in the communication line K076en 1999-04 Polling Mode ID A 1. The main system sends a polling command with an ID Main system Polling is necessary if several transmitters share the same communication line All transmitters need to have unique IDs ID B ID C 2. Only a transmitter with correct ID responds with a data message K076en 1999-04 Configuration OR T x D R x D G N D K076en 1999-04 Set up the terminal program ... use 100 ms time delay between each line Type RESET <Enter> ... if not included in the file ... or reset the transmitter Send the *.CFG file to the transmitter (could be named *.txt file as well) Type OPEN <Enter> Set up the terminal program Type RESET <Enter> ... or reset the transmitter Type commands to the transmitter Type OPEN <Enter> Two Methods of Configuration On-line Configuration File Transfer Configuration K076en 1999-04 Command Set Command Parameter Range Description SETSPD AVERAGE 0.25 .. 5.00 Wind speed [s] integration time SETDIR AVERAGE OFFSET 0.25 .. 5.00 -180 .. 180 Wind direction [] integration time Wind direction static correction [] SETCOM 0 or SETCOM 1 BAUDRATE DATABITS STOPBITS PARITY WIRES CCITT MULTIDROP ORIGINATE 300, .., 9600 7, 8 1, 2 NONE, EVEN, ODD 2, 4 V.21, V.22, V.23 0, 1 0, 1 Data transfer rate Number of databits (per frame) Number of stopbits (per frame) Parity Half duplex (2) or full duplex (4) Refers to modem speed Multibus access Modem originate/answer SETDEV ID String of five octets Device identification SETMEA WA151 SETMEA WMS301 SETMEA WMS302 SETMEA HMP45 SETMEA PT100 ACTIVE SPEED 0 / 1 LOW, NORMAL, HIGH Measurement active/inactive WA151 powering & sampling SETMES 1 or SETMES 2 or SETMES 3 or SETMES 4 TYPE COM INTERVAL TRIG COMOUT STRING CHECK POLY INIT REFIN REFOUT XOROUT NONE, OUT, IN, XDR_TU, MWV, MWVQUERY, MWVPOLL, WAT11 WAT11QUERY, WAT11POLL, DD50_TU, THRU 0, 1 0.0 .. 600.0 0 .. 4 0.. 1 string upto 80 chars NONE, XOR, SUM, CRC16 0000 .. ffff 0000 .. ffff 0, 1 0, 1 0000 .. ffff Pre defined messages Communication port number Sending interval [s] Message to be send; 0 = none Output port for THRU-message Message string format definition Checksum type CRC polynomial (hex) Checksum register initial value Reflection of incoming bits Reflection of outgoing bits XOR value for outgoing chksum SETHEA ACTIVE POLARITY TOS THYS 0, 1 0, 1 -55 .. 125 -55 .. 125 Heating OFF or ON Heat control polarity (1 as default) Heating OFF (polarity = 1) switching point (10 C as default) Heating ON (polarity = 1) switching point (5 C as default) K076en 1999-04 Block Diagram O p t i o n a l
C o m m u n i c a t i o n D i r e c t i o n
s e n s o r S p e e d
s e n s o r 6
V B a t t e r y + Heat Heat S e r i a l
I / O W M S 3 0 1 / 3 0 2 H M P 3 5 / 4 5 P t - 1 0 0 Isolated power supply section OVP/EMC Protection OVP + RS-485 drive 500kHz isolated power supply for RS-485 port Optional Communication Module Bus buffer + level shift OVP+ Sensor excitation unit GRAY input Speed input OVP +B uffers OVP MUX + OVP MUX + Hitachi H8 3048F CPU Reset 127 kB internal Flash Boot loader 128 kB- 512 kB SRAM External WD- timer 16-bit ADC + Programmable front-end Heat control 3V3 OK on/off 8 MHz ISO +5V ISO GND RS-Port 1 Power Good/Fail -> NMI +7/12 V to sensors + 5 V to ADC + 5 V to Comms module 3V3 to CPU 2.5 V ref. -3V to ADC Ext. DC level Heat AC 20 -> 40 V DC/AC 0 -> 2 A Raw 10 V F1 + Power ON Pulse/ f out Heat Heat Power OK 3V3 5V + 3 / 5 V INT 8bit CPU bus Serial SPI 100.00 100.00 0-12 V 2.50 V / 12 V Pulse input 0-12 V Fast DAC 0-12 V Fast DAC 0 -> 12 V Fast 10bit ADC 0 -> 12 V Fast 10bit ADC 12 V / 2.5 V excitation out Pulse input 3V3 3V3 SCL SDA SDA Heat ON status 3V3 3V3 +7 / 12 V +7 / 12 V Green Red Reset OVP+ Sensor excitation unit Two dual opto coupler isolation TxEN Enable 3V3 + 5 V - 3 V 2.5 V ref. RS-Port 2 Isolation 9809-006