1. A generator having a synchronous reactance of 0.9 pu based on its own rating is connected via a transmission line to a
bus, the voltage of which we may assume is kept constant at a value of 100 percent. The line has series impedance of
j0.15 pu, based upon the machine MVA. The internal emf E of the machine is kept at a constant magnitude of 135
percent. A) Compute the steady state stability power limit (pullout power) of the machine if operated as a generator. B)
At the moment of pullout, determine the magnitude and direction of the reactive power at the generator terminals.

2. Considere una mquina sincrnica operando en vaco. Suponga que por un mal diseo del entrehierro, las inductancias
mutuas de los devanados del estator con el devanado de excitacin no son puramente sinusoidales y contienen una
componente de tercer armnico. A) Compruebe que cada tensin de fase contendr una componente a 180 Hz. B)
Compruebe que esta componente de 180 Hz no est presente en las tensiones de lnea.

3. Un generador sncrono se conecta a una barra infinita cumpliendo con todas las condiciones requeridas para ello; una
vez sincronizado, se modifica el par mecnico de tal forma que la mquina entrega una potencia activa igual al 30% de
su potencia nominal. A) indique si en esas condiciones la mquina genera o absorbe potencia reactiva. Justificar la
respuesta. B) Si posteriormente se incrementa la corriente de excitacin en un 30%, determine la potencia compleja
entregada por la mquina.

4. A generator with reactance Xd = 1.6 and Xq = 0.9 delivers SG = 1 |45 to a bus with voltage Va = 1 |0. Find Ia, Id, Iq, Ea
and the initial rotor angle do.

5. A 100MVA, 20.0kV, 60Hz, four poles, Y-connected, three-phase alternator has an armature winding resistance of 0.15
and a synchronous reactance of 4.80. The armature reaction can be related to the armature current by the EMF Ear =
-j4.20 Ia. Assume that the air-gap line slope is 12.60V/A. Compute the field current required to establish rated voltage
across the terminals of a load that draws 100 per cent of rated current at 0.80 power factor lagging.

6. Un generador sincrnico de polos salientes est conectado en Y y se encuentra en vaco. La tensin en bornes de la
mquina es 1.02 p.u. y sus parmetros de impedancia son: ra = 0.12 p.u.; Xd = 1.2 p.u. y Xq = 0.7 p.u. Si sbitamente
se llegase a conectar una carga resistiva pura en conexin Y, de valor por fase igual a 0.88 p.u., determinar la corriente
de armadura de estado estable que tendra la mquina.

7. A round-rotor synchronous generator is in steady state with = o t + 158.95, Va = 1.0 | 0 e Ia = 1 | 30. Find its
internal voltage and its synchronous reactance. Neglect the resistance.

8. Un generador sincrnico se conecta a una barra infinita a travs de una lnea corta y sin prdidas de reactancia igual a
0.15 p.u., cumpliendo todas las condiciones requeridas para ello. La tensin en la barra infinita es 1.05 p.u., la
resistencia de armadura de la mquina es 0.15 p.u. y las reactancias son: Xd = 1.2 p.u. y Xq = 0.6 p.u.. Si la potencia
mecnica suministrada al generador se incrementa lentamente hasta alcanzar una potencia generada igual a 0.4 p.u.,
manteniendo la corriente de excitacin constante, y posteriormente la corriente de excitacin se incrementa en un 30%,
manteniendo el par constante, determinar los fasores de corriente de armadura, tensin en bornes de la mquina y
tensin inducida interna en la mquina.