You are on page 1of 4

Our energy working for you.

TM
Diesel generator set
N14 series
Specification sheet
304 kWe, 380 kVA Prime
Lowest life cycle cost
N14 series design features have made Cummins

diesel, the
standard for comparison of operating economy, reliability and
long life. When all cost factors like initial purchase, fuel, lube oil,
maintenance and overhaul are considered, the bottom line will
show that this Cummins

N14 series will deliver the lowest life


cycle cost.
Heavy duty, durable and emission
compliant
Cummins

N14 series diesel engine comes with heavy duty


features, bigger size camshaft, optimized turbo-matching,
electrical STC Injectors and is yet compact in size with optimum
power to weight ratio making it the obvious choice for your
long-term power needs.
The Genset powered by the reliable
Cummins

N14 series diesel


engine meets stringent exhaust
emission tests as per MOEF norms
without sacrificing fuel efficiency at
normal operating loads.
Silent Power
Cummins

380 kVAenclosure is so designed as to have


optimum performance and serviceability over the complete
operating range. The enclosure is compact with integral fuel tank
and is designed for ease in maintenance. The powder coated
enclosure is manufactured on latest CNC machines to ensure
superior finish and durability.
Single source power assurance
Design, manufacture and testing of engine, alternator, enclosure
and other accessories is done by Cummins Group of companies
for that optimum performance integrity and is backed by
countrywide product support network with single source
responsibility for the entire package.
Standard scope
Engine: Cummins

N14 series, direct injection, water cooled


engine, 6 cylinder, in-line, 4 stroke, rated at 1500 RPM,
conforming to ISO 3046 / BS 5514 has the following
specifications:
- Cummins PT fuel pump, Step Timing Control (STC) injector
- Holset turbocharger, pulse tuned exhaust manifold,
stainless steel exhaust flexible coupling
- Radiator or heat exchanger, coolant inhibitor,
Low Temperature After cooling (LTA)
- Articulated piston
- Gear train with spur gears
- Plate type lube oil cooler
- Spin-on filters - fuel, lube oil and coolant
- Dry type replaceable paper element air cleaner with restriction
indicator
- Flywheel housing & flywheel to suit single bearing alternator
- Starting motor electric
- First fill lube oil
PowerCom

controller: A Cummins manufactured


microprocessor based genset controller for metering, monitoring,
protecting and electronic governing of the engine.
2007 Cummins Power Generation Specifications subject to change without notice
Accessories shown are not part of standard equipment
PGBU/CIL/003/N14 380 kVA/CPG/June 2007/1000
2007 Cummins Power Generation Specifications subject to change without notice
Accessories shown are not part of standard equipment
PGBU/CIL/003/N14 380 kVA/CPG/June 2007/1000
Our energy working for you.
TM
www.cumminsindia.com
Alternator: Stamford brushless alternator
- Self-excited, self regulated
- Class H insulation
- Salient pole revolving field
- Single bearing
- Automatic voltage regulator
Accessories:
- Silencer suitably optimized to meet stringent sound emission
standards laid down by MOEF / CPCB
- Base rail with integral fuel tank (520 litres capacity) is provided
with drain plug, air vent, inlet and outlet connection, level
indicator, manhole etc.
- 2 x 12 V dry, uncharged batteries with connecting leads and
terminals
Acoustic enclosure:
- Specially designed to meet stringent MOEF/ CPCB norms of
75 dBA @ 1mtr at 75% load under free field conditions
- Designed to have optimum serviceability
- Air inlet louvers specially designed to operate at rated load
even at 50 deg C air inlet temp.
- Made on special purpose CNC machines for consistency in
quality and workmanship
- Powder coated for long lasting service life and superior finish
- With UV resistant powder coating, can withstand extreme
environments
- Use of stainless steel hardware
- Insulation material meets exacting IS 8183 specs for better
attenuation
Optionals
Engine: Heavy duty air cleaner, heat exchanger, lube oil/
Coolant heater with thermostatic switch
Alternator: RTDs, BTD, PMG excitation, space heater
Control panel: "PowerCommand

Control Panel (PCC 3100)"
for microprocessor based governing, regulation, metering,
monitoring and auto synchronising control system. AMF control
panel, battery charger, remote/ auto start panel, auto/ manual
synchronizing panel and audio/ visual annunciation for faults.
Others: Mobile sets with canopy
Control panel: Powder coated control panel manufactured
with 14 / 16 gauge CRCA sheet provides:
- MCCB of suitable rating with overload and short circuit
protection
- Combined meter for Voltage, amps and frequency
- Combined meter for KW, kVA and PF
- KWh meter
- Indicating lamps for DG On and Load On
- Current transformers
- Aluminium busbars of suitable capacity with incoming and
outgoing terminations
- Instrument fuses/ MCB duly wired and ferruled
- Engine protection for low lube
oil pressure, high coolant
temperature (alarm and
shutdown)
- Alternator protection
parameters like under voltage,
over voltage, over frequency,
over current, under frequency
(alarm and shutdown)
- Relay drivers for remote annuciations
- Cyclic cranking
- Auto/ manual start/ stop
- Alternator trim adjustment from the front key pad
- Model specific calibration from the front key pad
- Speed bias or raise/ lower inputs are provided for paralleling
- Remote monitoring capability through separate interface modules
- 6 configurable discrete outputs
- 2 configurable discrete inputs
- Smooth transition to rated speed
- Smart start algorithm
- Housed in a NEMA 3R/IP 53 non-metallic enclosure
- Operates within a wide temperature range (0-60 degrees C) and
humidity up to 95%
PowerCom

features:
- Engine electronic governing
- Genset metering parameters like lube oil pressure, coolant
temperature, engine speed (rpm), run hours, DC voltage,
intake manifold temperature (wherever applicable), 3 phase
volts and 3 phase amperes, frequency, kW, kVA, power factor
Technical data
Generator set specifications
Model C 380 D5 P
Prime Power Rating kVA 380
Output Voltage and Frequency 415 Volts, 50 Hz
Power Factor 0.8 (lag)
No. of phases 3 phase
Engine specifications
Make Cummins
Model NTA 14 G3
No. of cylinders 6, in- line
Aspiration Turbocharged-Aftercooled
Bore x Stroke 140 mm x 152 mm
Displacement 14 ltrs
Output - Prime 336 KWm
Fuel consumption @ 75% load with Radiator & Fan 58.2 ltr/hr
Fuel consumption @ 100% load with Radiator & Fan 76 ltr/hr
Typical lube oil consumption @ full load 0.092 ltr/hr
Total wet weight ( engine + radiator) 1620 kg
Length x Width x Height (engine) 1655 x 900 x 1313 mm
Compression Ratio 17:1
Piston Speed 7.6 m/s
Governor /Class Electronic /A1
Lubricating oil sytem capacity 38.6 ltrs
Coolant capacity (engine + radiator) 76.8 ltrs
Combustion air intake @ 100% load (+/- 5%) 223.7 m
3
/min
Fan air flow across radiator 623 m
3
/min
Exhaust Temperature 527
o
C
Battery Capacity /Rating 180 AH, 2 X 12 V
Alternator specifications
Make Stamford
Frame size /Model No. HC4F
Voltage Regulation + 1%
Insulation Class H
Standard Enclosure IP 23
Winding Pitch 2 /3 Pitch
Stator Winding Double layer lap
Rotor Dynamically balanced
Wave form distortion No load < 1.8 %, non distorting
balanced linear load < 5 %
Telephone Interference Factor Better than 50
Total Harmonic Factor Better than 2%
2007 Cummins Power Generation Specifications subject to change without notice
PGBU/CIL/003/N14 380 kVA/CPG/June 2007/1000
Our energy working for you.
TM
www.cumminsindia.com
Conformance standards
IS 4722, BS 5000, IEC 34 / 1, ISO 8528, BS 5514, ISO 3046
Rating definition
- Prime power rating is applicable for supplying continuous
electric power (at variable load) in lieu of commercially
purchased power.
- Prime power is available for an unlimited number of hours
per year in a variable load application.
- 10% overload is available for 1 hour in every 12 hours of
operation.
- Rating definition is as per ISO 3046 / BS 5514.
- Fuel consumption data is based on diesel having specific
gravity of 0.85 and conforming to IS:1460/ Equivalent
- Oil consumption data is based on oil having specific gravity of
0.89 and meeting CH4 API categories
- Fuel consumption tolerance is +5%
Typical diesel genset dimensions
Genset Model Rating (kVA) Length (mm) Width (mm) Height (mm) Weight (kgs.) (Dry)
C 380 D5 P 380 kVA 5500 2000 2500 7215
Typical enclosed genset dimensions*
Genset Model Rating (kVA) Length (mm) Width (mm) Height (mm) Weight (kgs.) (Dry)
C 380 D5 P 380 kVA 3387 1576 1988 3215
Cummins India Limited
Power Generation Business Unit
35A/1/2, Erandawana,
Pune 411 038. India
Tel.: (91) 020-6602 7525
Fax: (91) 020-6602 8090
Authorised
Representative
Cummins Power Generation Offices:
Location: Tel: Fax:
Bangalore: (080) 2361 3831/ 2361 1958 (080) 2361 4552
Chandigarh: (0172) 506 3218 (0172) 266 3087
Chennai: (044) 2441 6429/ 2442 3412 (044) 2491 1120
Delhi: Telefax: (011) 4161 8357/ 61
Hyderabad: (040) 2766 3017 (040) 2767 8892
Location: Tel: Fax:
Indore: (0731) 645 1042
Jaipur: (0141) 236 4944 (0141) 236 3746
Kolkota: (033) 2287 8065/ 2247 2481 (033) 2290 3839
Lucknow: (0522) 278 6718/ 278 7514 (0522)278 7880
Mumbai: (022) 2756 6351/ 52/ 53/ 54 (022) 27566355
Vadodara: (0265) 232 4207/ 654 0390 (0265) 234 0623
2007 Cummins Power Generation Specifications subject to change without notice
Cummins and PowerCommand are registered trademarks of Cummins Inc.
*Dimensions of the enclosure are excluding the silencer
Information contained in this publication is typical only and does not form part of any
contractual commitment
PGBU/CIL/003/N14 380 kVA/CPG/June 2007/1000