Professional Documents
Culture Documents
AIR COOLED
LIQUID COOLED
Genset Type
1500
r/min
LAT 8A*
LAT 15
LAT 15A
LAT 24
LAT 24A
LWA 10
LWA 10A
LWA 14
LWA 14A
LWA 15
LWA 15A
LWA 22
LWA 22A
LWA 20
LWA 20A
LWA 30
LWA 30A
LWA 27
LWA 27A
50 Hz
3000
r/min
TR3
LPW(S)2
LPW(S)3
LPW(S)4
LPW(S)T4
kVA / kWe
4.6
4.6
8.9
8.9
14.5
14.5
6.1
6.1
9.3
9.3
12.5
12.5
15.8
15.8
kVA / kWe
4.8
4.8
9.4
9.4
15.2
15.2
6.3
6.3
9.8
9.8
13.1
13.1
16.5
16.5
kVA
6.2
6.2
12.5
12.5
19.4
19.4
8.1
8.1
12.5
12.5
16.8
16.8
21.4
21.4
kWe
5.0
5.0
10.0
10.0
15.5
15.5
6.5
6.5
10.0
10.0
13.4
13.4
17.1
17.1
kVA
6.5
6.5
13.1
13.1
20.3
20.3
8.5
8.5
13.0
13.0
17.6
17.6
22.4
22.4
kWe
5.2
5.2
10.5
10.5
16.2
16.2
6.8
6.8
10.4
10.4
14.1
14.1
17.9
17.9
Prime
kVA / kWe
10.2
10.2
16.1 [3]
16.1 [3]
22.0 [3]
22.0 [3]
Standby
kVA / kWe
10.7
10.7
16.8 [3]
16.8 [3]
23.0 [3]
23.0 [3]
kVA
13.6
13.6
21.1 [3]
21.1 [3]
29.3 [3]
29.3 [3]
kWe
10.9
10.9
16.9 [3]
16.9 [3]
23.4 [3]
23.4 [3]
kVA
14.3
14.3
22.1 [3]
22.1 [3]
30.7 [3]
30.7 [3]
kWe
11.4
11.4
17.7 [3]
17.7 [3]
24.5 [3]
24.5 [3]
Prime
Three
phase
TR2
Prime
Standby
Single
phase
TR1
Standby
Prime
Three
phase
LAT 8
Engine model
Single
phase
T Series
Standby
Cylinders
Number of cylinders
Injection
D=direct, I=indirect
D (I)
D (I)
D (I)
D (I)
D (I)
D (I)
D (I)
D (I)
D (I)
D (I)
D (I)
D (I)
D (I)
D (I)
Aspiration
Governing
M=mechanical, E=electronic
Alternator
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Battery
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Engine
dBA at 1 m
dBA at 7 m
E=engine-mounted, R=residential, ( )=optional
Weight
Length
Width
Height
MR / AMF
MR / AMF
MR / AMF
E (R)
N/D
64
R
E (R)
kg
358
412
428
521
lb
789
908
944
1149
mm
1080
1390
1190
1500
in
42.5
54.7
47.0
59.1
mm
698
705
698
in
27.5
27.8
mm
972
in
38.0
At 75% load
N/D
N/D
64
R
MR / AMF
N/D
64
R
518
1142
1400
55.0
705
27.5
27.8
1070
972
42.1
38.0
N/D
MR / AMF
E (R)
N/D
64
R
625
374
1378
825
1675
65.9
698
MR / AMF
E (R)
N/D
TBA
R
E (R)
428
374
428
944
825
944
1106
1390
1106
43.5
54.7
43.5
705
698
705
27.5
27.8
27.5
27.8
1070
972
1070
992
42.1
38.0
42.1
39.0
N/D
E (R)
N/D
MR / AMF
N/D
64
R
E (R)
395
488
871
1076
1390
1216
54.7
47.9
698
705
27.5
27.8
1070
992
42.1
39.0
N/D
MR / AMF
N/D
TBA
R
E (R)
395
488
871
1076
1500
1216
59.1
47.9
698
705
27.5
27.8
1070
992
42.1
39.0
N/D
MR / AMF
N/D
65
R
E (R)
434
541
957
1193
1500
1436
59.1
56.5
698
705
27.5
27.8
1070
992
42.1
39.0
N/D
MR / AMF
N/D
TBA
R
E (R)
434
541
444 [1]
551 [1]
957
1193
979 [1]
1215 [1]
1675
1475
1675
1436
1675
65.9
58.1
65.9
56.5
65.9
698
705
698
705
698
705
27.5
27.8
27.5
27.8
27.5
27.8
1070
992
1070
992
1070
992
1070
42.1
39.0
42.1
39.0
42.1
39.0
42.1
N/D
N/D
N/D
N/D
62 [2]
R
Lister Petter alternators are standard. N/A = not applicable; N/D = no data available; TBA = to be announced
[1] Weight and dimensions for LPWST4 vary from LPWT4; [2] 59.2 dBA for LPWST4; [3] Both LPW and LPWS engines available, but require LPWS for
exhaust emissions compliance.
DIESEL
LIQUID COOLED
Engine series
Model code
Genset Type
LWA 41A
LWX 27
LWX 27A
Engine model
Single
phase
1500 r/min
50 Hz
Single
phase
3000 r/min
Engine
Three
phase
Three
phase
LLG 30
LLG 30A
LLG 50
LLG 50A
LLG 70
LLG 70A
LLG 100
DWS4
LPWX4
GW3
GW4
GWT4
GWT6-1A
GWT6-2A
LLO
200/175
O
LLO
200/175A
A
Omega Series
LLO
LLO
200/200 200/200A
O
A
GWTA6
LLO
200/225
O
LLO
200/225A
A
OWTA6
kVA / kWe
15.0
15.0
23.2
23.2
Standby
kVA / kWe
15.7
15.7
25.5
25.5
kVA
20.0
20.0
30.0
30.0
30.0
30.0
45.0
45.0
63.0
63.0
90.0
90.0
100
100
125
125
175
175
200
200
225
225
kWe
16.0
16.0
24.0
24.0
24.0
24.0
36.0
36.0
50.0
50.0
72.0
72.0
80.0
80.0
100
100
140
140
160
160
180
180
Prime
Standby
kVA
21.0
21.0
33.0
33.0
33.0
33.0
50.0
50.0
69.0
69.0
100
100
110
110
138
138
193
193
220
220
248
248
kWe
16.8
16.8
26.4
26.4
26.0
26.0
40.0
40.0
55.0
55.0
80.0
80.0
88.0
88.0
110
110
154
154
176
176
198
198
Prime
kVA / kWe
31.3
31.3
Standby
kVA / kWe
32.8
32.8
kVA
41.8
41.8
kWe
33.4
33.4
kVA
43.8
43.8
kWe
35.0
35.0
Prime
Standby
Cylinders
Number of cylinders
Injection
D=direct, I=indirect
D (I)
D (I)
Aspiration
T, I
T, I
T,I
T,I
T,I
T,I
T, I
T,I
Governing
M=mechanical, E=electronic
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Silencers
Gamma Series
Prime
Alternator
Noise Rating
LPWT4
Delta Series
dBA at 1 m
At 75% load
dBA at 7 m
E=engine-mounted, R=residential, ( )=optional
Weight
Length
Width
Height
MR / AMF
N/D
E (R)
N/D
TBA
R
Leads only
MR / AMF
MR / AMF
N/D
N/D
N/D
E (R)
N/D
70
R
Leads only
MR / AMF
Leads only
MR / AMF
Leads only
MR / AMF
N/D
N/D
N/D
N/D
N/D
N/D
73.5
R
Leads only
MR / AMF
Leads only
MR / AMF
MR / AMF
MR / AMF
N/D
N/D
N/D
N/D
N/D
N/D
97
87
E
N/D
78.7
R
MR / AMF
97
87
E
N/D
78.7
R
MR / AMF
97
87
E
N/D
78.7
R
kg
444
551
434
541
592
820
775
1280
1193
1686
1431
1921
1860
2493
1860
2493
1876
2509
2000
3410
2100
3410
2200
3410
lb
979
1215
957
1193
1305
1808
1707
2820
2630
3717
3155
4235
4101
5496
4101
5496
4136
5531
4400
7517
4620
7517
4840
7517
mm
1475
1675
1436
1675
1600
2000
1900
1950
2200
2645
2200
2645
2640
3366
2640
3366
2640
3366
2790
3900
2790
3900
2790
3900
in
58.1
65.9
56.5
65.9
63.0
78.9
74.8
77.0
86.6
104.1
86.6
104.1
103.9
132.5
103.9
132.5
103.9
132.5
110
153.5
110
153.5
110
153.5
1463
mm
698
705
698
705
700
850
710
1050
996
1000
996
1000
1093
1100
1093
1100
1093
1100
870
1463
870
1463
870
in
27.5
27.8
27.5
27.8
27.5
33.5
28.4
41.0
39.2
39.4
39.2
39.4
43.0
43.3
43.0
43.3
43.0
43.3
34.0
57.6
34.0
57.6
34.0
57.6
mm
992
1070
992
1070
1110
1300
1300
1600
1527
1643
1527
1643
1677
1949
1677
1949
1677
1949
1600
2151
1600
2151
1600
2151
in
39.0
42.1
39.0
42.1
43.7
51.1
51.0
63.0
60.1
64.7
60.1
64.7
66.0
76.7
66.0
76.7
66.0
76.7
63.0
84.7
63.0
84.7
63.0
84.7
Lister Petter alternators are standard. N/A = not applicable; N/D = no data available; TBA = to be announced
[1] Weight and dimensions for LPWST4 vary from LPWT4; [2] 59.2 dBA for LLD 250A and 59 dBA for LWX 27A; [3] Both LPW and LPWS engines available,
but require LPWS for exhaust emissions compliance.