You are on page 1of 3

Wire Free Alliance > Discussions for Wireless Network > Live Optimization > Orig

inal Problem in Handover


PDA
View Full Version : Original Problem in Handover


haq_enam
2011-04-13, 04:12 PM
We recently swap ericsson to Huawei and have not fimillier with parameters... On
e of the building we have done DT and found that outdoor(Serving) rxlevel is -95
dBm and indoor(neigbor) is -65dBm but it should have oppsite. As indoor site in
higher priority that outdoor and clean frequency is used....
I dont no any parameters that will help to solve the problems....It ishappening
only dedicated mode but idel mode it is okey... Pls provide solution if u have..
.
DL PC is off
RF engineer
2011-04-13, 05:03 PM
We recently swap ericsson to Huawei and have not fimillier with parameters... On
e of the building we have done DT and found that outdoor(Serving) rxlevel is -95
dBm and indoor(neigbor) is -65dBm but it should have oppsite. As indoor site in
higher priority that outdoor and clean frequency is used....
I dont no any parameters that will help to solve the problems....It ishappening
only dedicated mode but idel mode it is okey... Pls provide solution if u have..
.
DL PC is off
Dear
In huawei the 1800 have higher priority ( layer 2) and 900 have (layer 3).What y
ou have to check in system parameter called Cell layer if the are not as above c
hanged , then you have another parameter to control HO between two band called i
nter-layer HO threshold if this parameter is put high value let say 45 it is bet
ter to change to 35 or less if you see still have good RF condition.
BR
haq_enam
2011-04-13, 06:07 PM
Dear
In huawei the 1800 have higher priority ( layer 2) and 900 have (layer 3).What y
ou have to check in system parameter called Cell layer if the are not as above c
hanged , then you have another parameter to control HO between two band called i
nter-layer HO threshold if this parameter is put high value let say 45 it is bet
ter to change to 35 or less if you see still have good RF condition.
BR
Thanks for reply..
Site is already layer 2 and inter-layer HO threshold is 25.
Any other parameters to change or modify
RF engineer
2011-04-13, 10:59 PM
Thanks for reply..
Site is already layer 2 and inter-layer HO threshold is 25.
Any other parameters to change or modify
is it defined as neighbor.
BR
theumar@hotmail.com
2011-04-13, 11:00 PM
Layer Settings are correct and based on algorithm call should not be camped on o
utdoor 900 cell. Even if HO triggered due to Quality it should be on 2nd best ce
ll. Can you check before HO trigger, what was the quality of connection and Chec
k in L3 signalling msgs that prior HO in MR that MS sent to network what was the
ranking of nbr cells
Probability of following parameter to be wrong is least but do check them
1. Inter Layer HO Hysterysis should be around 4
2. BQ Margin set on relationship level default is 64 ( means 0 )normal range is
68 ( 68- 4= 4 dB margin) setting high values of BQ margin on a specific relation
makes it more favourable candidate in case of quality HO triggered
riyantoyadi
2011-04-13, 11:07 PM
what's BQ Margin set? please describre this
theumar@hotmail.com
2011-04-13, 11:11 PM
HW Parameter to Control the selection of candidate cell in case of urgency quali
ty reason HO Triggered
riyantoyadi
2011-04-13, 11:26 PM
please share to us any related document about this. We will very appreciated
haq_enam
2011-04-15, 12:26 AM
is it defined as neighbor.
BR
Neighbor is defined.....it is not happening in all floors
riyantoyadi
2011-04-15, 12:29 AM
please check this
1. Power Control setting
2. try to turn off PC on indoor building
RF engineer
2011-04-15, 02:16 PM
Neighbor is defined.....it is not happening in all floors
Dear
The two snap is different in the first one the call in 900 and second one is on
1800 so handover happen in the same floor? and the source cell and Neighbour are
on the same BSC if not check External HO relation defined.
What about the PBGT HO threshold and inter-cell HO hystersis and try to delete t
he neighbour and redefined again .
BR
haq_enam
2011-04-16, 12:48 PM
please check this
1. Power Control setting
2. try to turn off PC on indoor building
U r asking dor both PC off...WE did UL PC ...
haq_enam
2011-04-16, 12:52 PM
Dear
The two snap is different in the first one the call in 900 and second one is on
1800 so handover happen in the same floor? and the source cell and Neighbour are
on the same BSC if not check External HO relation defined.
What about the PBGT HO threshold and inter-cell HO hystersis and try to delete t
he neighbour and redefined again .
BR
Both are in 4dB...HO between 900 and 1800....

vBulletin v4.1.12, Copyright 2000-2014, Jelsoft Enterprises Ltd.

You might also like