You are on page 1of 51

1

Outline of Equipment Available for Sale



Boiler

The boiler is corner fired using residual fuel oil and is an NEI - ICL design. The boiler in its
current state has 16 tilting burners (four per corner) and will comprise a single furnace
compartment with a main and a rear gas pass, 2-bank feed water economiser, six horizontal
superheater stages, and a single stage reheater. Water circulation through the furnace wall
tubes will be assisted by electrically driven circulating pumps (constant speed)

Boiler Specification
Manufacturer NEI-ICL
Type HFO
Normal Output 300 MW
Max. Evaporation @ MCR 258.33 kg/s
Superheater Outlet Pressure 170 bar
Superheater Outlet Temperature 540

C
Reheater Outlet Temperature 540

C
Economiser Water Inlet Temperature 250

C

Boiler Circulating Pumps
Number required per unit 3
Manufacturer HAYWARD TYLER
Flow Rate 4.05 x 1000,000 kg/hr
Motor details 1460 rpm, 540 kW @ 3.3 kV

Induced Draught Fans
Number required per unit 2
Manufacturer DAVIDSON Co. LTD
Type D1.BAB 143
Output Control Radial Inlet Vanes
Gas Volume 176.0 m
3
/sec. establishing
36.35 m back suction
Gas Temperature 150

C
Motor Details 980 rpm, 934 kW @ 11 kV

Forced Draught Fans
Number required per unit 2
Manufacturer DAVIDSON Co. LTD
Type D1.BAB 92A
Output Control Radial Inlet Vanes
Air Volume 116.5 m
3
/sec. establishing
55.0 m back pressure
Air Temperature 27

C
Motor Details 980 rpm 952 kW @ 11 kV



2
Gas Recycling Fans
Number required per unit 2
Manufacturer DAVIDSON Co. LTD
Gas Volume 48.12 m
3
/sec
Output Control Hydraulic Coupling

Gas Air Heaters
Number required per unit 2
Manufacturer DAVIDSON Co. LTD
Type Rothemuhle
Gas flow entering heater 244.76 m
3
/sec @ MCR
Air flow leaving heater 202.60 m
3
/sec @ MCR
Gas inlet temperature 349

C
Hood speed 0.78 rpm

Steam Air Heaters
Number required per unit 6
Manufacturer SPIRAL TUBE LTD.

Sootblowers
Number required per unit 28
Manufacturer HOPKINSON
Fitted to automatically blow in sequence
superheater, reheater, economiser and
Airheaters (long lance / rake type)

H.P. Oil Pumps
Number required per unit 3
Manufacturer HAMWORTHY ENG. LTD
Model To be advised
Type Screw pump
Duty 50,000 kg/hr

L.P. Oil Pumps
Number required per unit 3
Manufacturer HAMWORTHY ENG. LTD
Model SHO940M3
Type Screw pump
Duty 50,000 kg/hr

Auxiliary Oil Pump
Number required per unit 1
Manufacturer HAMWORTHY ENG. LTD
Model SHM210ER40D
Type Screw pump
Duty 8,000 kg/hr


3
Turbine

The G.E.C. Turbine Generators designed turbine generator is a three cylinder
impulse/reaction type driven by superheated steam from the boiler. The turbine will be
directly coupled to the generator capable of generating 300 MW of electrical power at 17
kilovolts.

Number required per unit 1
Manufacturer G.E.C. Turbine
Generators Ltd
Type Impulse Reaction, Axial flow.
H.P. and I.P. cylinders single flow,
L.P. cylinder double flow, single reheat, tandem
compound.
Speed 3,000 rpm
Heat Rate 8,009 kJ/kWh
Output 300 MW (E)
Barring gear 32 rpm
Support M.A.N. steel platform

HP Turbine: (9 Stages)
Number required per unit 1
Steam Conditions HP Inlet 162 bar g 538

C
HP Exhaust 41 bar g 346

C

The HP Turbine cylinder is a double shell design, comprising an inner and outer casing, each
divided and bolted at its horizontal line joint. Each casing is cast separately in Cr-Mo-V
steel. The HP Rotor is machined from a Cr-Mo-V steel forging with nine blade disc formed
integral with the rotor and will be bolted to the IP rotor shaft through a rigid coupling.

IP Turbine: (11 Stages)
Number required per unit 1
Steam Conditions IP Inlet 36.64 bar g 538

C

The IP turbine consists of an outer casing enclosing the rotor. The first five of eleven stages
of rotor blading are enclosed in an inner casing supported in the outer casing. The CR-Mo-V
inner and outer casings are flanged along their horizontal centre lines to allow for bolting
together. The IP turbine rotor is forged in Cr-Mo-V steel with eleven discs formed integral
with the shaft.

LP Turbine:
(Double flow - 5 stages)
Number required per unit 1
Steam Conditions LP Inlet 4.05 bar g 253

C

The LP turbine cylinder comprises an inner casing, each split on the horizontal line. The
bottom half of the outer casing forming the exhaust chamber to the condenser. The LP rotor
4
is machined from Ni-Cr-Mo-V alloy steel forging with an integral half coupling at each end
connecting the rotor to the IP turbine and the generator.

Main Electrical Equipment

Generator:
Number required per unit 1
Manufacturer G.E.C. Turbine Generators Ltd.
Rating - MCR 300 MW/ 353 MVA
Voltage 17 kV
Stator Current 12,000 A
Power Factor 0.85 lagging
Short Circuit Ratio 0.45
Speed 3,000 rpm
Frequency 50 Hz
Phases 3
Poles 2
Excitation Voltage 404 V
Excitation Current 2,676 A
No Load Current 875 A
Stator Insulation Class B
Insulation Coolant demineralised water
Hydrogen Pressure 3.1 bar g
Rotor Insulation Class B
Coolant Hydrogen

Exciter:
Number required per unit 1
Output 1,450 kVA
Rating 1,390 kW
Current Rating 2,350 A
Voltage 356 V
Power Factor 0.96 lagging
Frequency 100 Hz
Coolant Air

Pilot Exciter:
Number required per unit 1
Type 16 Pole Permanent magnet generator
Rating 30 kVA/27kW
Power Factor 0.9 lagging
Current 0 - 158 A
Frequency 400 Hz
Coolant Air

Generator Protection:
Manufacturer BROWN BOVERI LTD.

5
Generator Circuit Breakers:
Manufacturer BRITISH BROWN BOVERI
Type DR 36 SC 1750/1
Rating 17 kV - 12,700 A.

Feed Heating Plant:
3 HP stages
3 LP stages and Deaerator
Drains Flash Condenser and Gland Steam Condenser
Each Feed Heater comprises a heater shell, a tube-nest assembly and an inlet and outlet
waterbox. The high level Deaerator consists of a cylindrical storage vessel upon which is
mounted a deaerating chamber and a vent condenser.

LP Heaters: (1,2 & 3)
Number required per unit 3
Manufacturer G.E.C. Ltd
Steam Side Design Pressure 2.28 bar gauge
Steam Side Design Temperature 135C
Water Side Design Pressure 15.85 bar gauge
Water Side Design Temperature 104C
Tube material 70/30 Brass
Tube size 19.05mm x 1.22 mm thick

Deaerator:
Number required per unit 1
Manufacturer G.E.C.
Vent Condenser Design Press. 5.17 bar (A)
Design Temp. 343

C
No. off Tubes 1,204
Material Stainless Steel
Heater Design Press. 5.17 bar (A)
Design Temp. 343

C
Storage Tank Design Press. 5.17 bar (A)
Design Temp. 343

C

H.P. Feed Heaters: (4, 5 & 6)
Number required per unit 3
Manufacturer G.E.C. Ltd
Heater 4
Steam Side Design Pressure 11.1 bar
Steam Side Design Temperature 280C
Water Side Design Pressure 247 bar
Water Side Design Temperature 253C
Tube material cold drawn steel
Tube size 19.05mm x 2.03 mm thick
Heater 5
Steam Side Design Pressure 20.5 bar
Steam Side Design Temperature 280C
6
Water Side Design Pressure 247 bar
Water Side Design Temperature 253C
Tube material cold drawn steel
Tube size 19.05mm x 2.03 mm thick
Heater 7
Steam Side Design Pressure 49.5 bar gauge
Steam Side Design Temperature 280C
Water Side Design Pressure 247 bar gauge
Water Side Design Temperature 253C
Tube material cold drawn steel
Tube size 19.05mm x 2.03 mm thick

Boiler Feed Pumps:
Number required per unit 3
Manufacturer MATHER & PLATT
Duty 3 x 50%
Rated capacity/pump 9.336 m
3
/min
Discharge Press. 207.5 bar
Suction From high level Deaerator
Main pump 4 stage driven at
5,500 rpm (Max) through a combined Fluid
coupling gearbox.
Motor 1,488 rpm, 4.74 MW & 11 kV.
Booster pump Single stage direct drive
Number required per 300MW unit 3

Condenser:
Original design details (twin nest, single pass)
Number required per unit 1
Manufacturer G.E.C.
Number of tubes 11,300
Condenser backpressure. 50.9 mbar
Surface area 9338 m
2

Steam to Condenser 594,421 kg/hr
Cooling water Inlet 10.3

C
Cooling water Outlet 21.5

C
Cooling water flow 7.88 m
3
/sec (with clean tubes)
Overall tube length 10 .455 m
Outside tube diameter 25.4 mm
Tube wall thickness 1.22 mm
Tube material Aluminium brass or titanium





7
Balance of Plant

The results of the DMD investigations during the numerous site visits, and discussions with
various equipment suppliers into the possible erection of one of the spare units in a new
location the extent of the balance of plant required to erect a unit was determined.
The following list identifies the balance of plant required to be procured in addition to the
Existing components in order to complete a functioning coal fired generating unit. .
1 Boiler Modifications (convert from oil to coal firing only)
2 Ash handling plant (including dust handling and precipitators)
3 Coal handling plant
4 Coal bunkers
5 Coal mills and associated equipment- 4 mills (one unit)
6 CW pumps/intake system
7 Chimney
8 Water treatment plant/storage tanks
9 LP pipework systems
10 Fire protection and detection
11 Control and instrumentation
12 Cabling
13 Busbars/HV Switchyard Equipment
14 Generator transformer
15 Auxiliary Transformers
16 Switchgear
17 Civil works (including erection of a dedicated boiler/turbine house including
structural and supporting steelwork
18 Spares and Special tools
19 Data logger
20 Compressed air system
21 Turbine Hall crane, Auxiliary Cranes for the Mills and Boiler Feed Pumps
22 Insulation and cladding (for boiler and boiler and turbine piping)
23 Condenser internals (including tubes)

The Unit uses steam auxiliary boilers to supply needs such as fuel oil atomisation, soot
blowing, heat tracing fuel oil lines and fuel oil tank heating. The steam air pre-heater is
presently supplied with approximately 20,000 pounds per hour of steam from the #5
8
feedwater heater. Auxiliary steam is taken from the reheat steam lines when operating on
coal firing.

Only one 300MW Unit is for sale and in addition the scope of the purchase from AES does
not include fuel storage facilities, stack, gas clean up equipment, boiler support steel, cooling
water system, switchgear, valves, economiser pipework, Instrumentation and Control
Equipment, Water Treatment plant, lifting gear and exciter. Within the package limits,
however, the equipment is complete with missing items noted in this report.
The owner has extensive documentation on the plant design, and has stated that he will make
it all available to the buyer subject to clearance from the OEMs. The hard copies of the
engineering drawings are backed up on microfilm. With two units currently operating there
is every reason to believe that all of the necessary documentation for a retro-design and
timely installation are available.
Plant Inspection

DMD attended site and carried out a detailed plant inspection on various dates during March
2008.

The equipment is located at the power station site.
The inspection revealed that most plant items were still in the original manufactures packing
cases example (Figure 2). These may have to be re-boxed after inspection and prior to
shipping to site or for refurbishment if required. Larger components were stored on wooden
supports to protect machined surfaces for example LP turbine outer casings (Figure 3) etc.
All boiler panels are well stacked and supported. All boiler tubing, panels headers etc are all
sealed with plastic covers held in place with Denso tape (Figure 4). All boiler parts appear
to be fairly clearly marked, example (Figure 5).
All of the equipment that would appear to require dry storage is being stored either in the
main plant building or other storage sheds on site. A number of the large items such as the
steam drum (Figure 6), ducting (Figure 7), fan covers (Figure 8), support steel, low-pressure
steam piping (Figure 9) condenser water boxes (Figure 10) and LP Heaters (Figure 11) are
located in open storage. Although the ducting has been stored outside for many years it has
been retained in fairly good condition as a result of a long term contract with the original
supplier to keep it painted and corrosion free. This contract was only suspended a few years
ago. One item of plant that has suffered significant damage with storage outside is the air
9
heater hoods. While the basic structure of the hoods is sound the spring loaded rear shoes
and sealing ring (Figure 12) has suffered severe corrosion damage on all hoods.
All the HP, IP and LP inner turbine casings, valve steam chests and rotors are stored in the
turbine house building. Figures 13, 14 and 15 show one of the HP turbine outer casing top
halves, the valve steam chests and the LP rotor.
Figure 1 Typical Wooden Cases in store

10
Figure 2 LP Turbine casing

Figure 3 Boiler Panels

11
Figure 4 Example of Boiler Plant marking

Figure 5 Boiler Steam Drum

12

Figure 6 Boiler Ducting

Figure 7 ID Fan Cover

13
Figure 8 LP/IP Crossover Steam Piping

Figure 9 Condenser Water Boxes

14
Figure 10 LP feed Heaters

Figure 11 Air Heater Hood



15
Figure 13 HP Turbine Outer Casing Top Half


Figure 14 Turbine HP and IP Stop and Governor Valve Steam Chest Casings

16

Figure 15 LP Turbine Rotor


17
Inventory of Major Plant Items
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P02 Station Auxiliary Boiler System 1-Off Aux Boiler and Associated equipment Subject to further checks

P21 Turbine & Associated Equipment
New fasteners will be required for
existing plant before 2010. Fasteners not
available.

HP and IP Top & Bottom Loop Pipes
IP/LP Cross-over pipes Including Expansion Bellows and Associated Equipment
HP and IP Steam Chests Fasteners not available
HP and IP Stop & Governor Valves Require refurbishment/upgrade
HP and IP Steam Strainers

P21 04 HP Turbine Incl. All Associated Support &
Expansion Steelwork

Steam Inlet and Outlet Connections Located in turbine hall
HP Rotor Sited in Original storage Box Details and quotation for blading
performance upgrade - Part 2
Diaphragms & Diaphragm Glands Require refurbishment
Front & Rear Glands Fasteners not available Details and quotation for new casing
bolts included in Part 2
Top & Bottom Inner Casing Fasteners not available
Top & Bottom Outer Casing Fasteners not available
HP/IP Coupling and Bolts Original design bolts available Recommend Hydraulic bolts be fitted
No1 and 2 Pedestals Including Bearings and all Associated equipment without
liners


18
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P21 05 IP Turbine
Steam Inlet and Outlet Connections Located in turbine hall
IP Rotor Sited in Original storage Box Details and quotation for blading
performance upgrade - Part 2
Diaphragms and Diaphragm Glands Require refurbishment
Top and Bottom Inner Casings Fasteners not available Details and quotation for new casing
bolts included in Part 2
Top and Bottom Outer Casing Fasteners not available
Front & Rear Glands Fasteners not available
IP/LP Coupling and Bolts Original design bolts available Recommend Hydraulic bolts be fitted
Thrust Bearing and Associated Equipment Included with No2 pedestal
No3 Pedestal Including Bearings and all Associated Equipment without
liners

P21 06 LP Turbine
LP Rotor Located in turbine hall Performance upgrade and 5th stage
blade root mod details - Part 2
Diaphragms and Diaphragm Glands Located in turbine hall
LP Hood and Exhaust Chamber Bursting discs required
Top and Bottom Inner Casing Located in turbine hall
Steam Inlet and Outlet Connections Including Expansion Bellows and Associated Equipment
Bled Steam Outlet Connections Including Expansion Bellows and Associated Equipment
No4 Pedestal Including Bearings and all Associated Equipment without
liners

LP/Gen Coupling and Bolts Original design bolts available Recommend Hydraulic bolts be fitted


19
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P21 07 Turbine Support & Expansion
Main Steel Platform & Legs Located in turbine hall Seismic study required for new
location
Bedplates HP IP LP Generator and Brushgear Located in turbine hall
Expansion Blocks and Associated Equipment Located in turbine hall

P21 08 Turbine Gland Sealing
Strainers, HP, IP, LP Separators Not yet located
HP, IP, LP, De-superheaters Valves obsolete
Gland Steam Condenser Recently moved outside
Exhausters AB Annexe
Control, Drain and Isolating Valves As Available
HP/IP Gland Leak Off Valves obsolete

P21 09 Turbine Flange Warming Pipework to be identified

P21 10 Turbine Barring Gear Pedestal 4 -Located in turbine hall

P21 11 HP Turbine Drains
HP Drains Flash Vessel Recently moved outside
Spray and Isolating Valves Recommend new valves

P21 12 IP Turbine Drains
IP Drain Flash Vessel Recently moved outside
Spray and Isolating Valves Recommend new valves

20
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P21 13 LP Spray Water Cooling
Spray Water Pumps As Available

P21 14 Turbine Protection System Obsolete and incomplete Recommend new system

P21 15 Compressed Air Control System
Turbine Instrument Air and Loading Receivers Not available

P21 16 Turbovisory Obsolete and incomplete Recommend new system

P22 02 Lubrication Oil System Coolers not available
Main Oil Tank Recently moved outside
Main Oil Tank Strainer Not Available Further Due Diligence Required to
check what exactly is available.
Some parts have been used.
Oil Purifier Not Available

Main Oil Pump As available

Vent Blower As available

Aux Oil Pump (AC) As available

Booster Oil Pump As available

AC & DC Flushing Oil Pumps As available

Jacking Oil Pump As available

Duplex Oil Strainer As available

Thrust Bearing. Auto Clean Oil Filter As available

Pipework, Valves, Orifices As available


21
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P22 03 Governor Oil System Hardware Items Available
Governor (Original will need refurbished if used) Recommend new electronic system
HP Stop and Governor Valve Actuators (Original will need refurbished)
IP Stop and Governor Valve Actuators (Original will need refurbished)
Pipework, Valves and Associated Equipment Original valves will need refurbished
Power oil strainer (Original will need refurbished) Recommend new Pall duplex filter
P23 02 Condenser
Supports and Springs Erected with shell in turbine hall (not welded)
Waterboxes Recently moved outside
Shell Tube Plates and tubes not available Quotation for Titanium upgrade - Part
2
Inlet and Outlet Isolating Valves To be Refurbished if Available
CW Priming Pumps Not supplied may not be required for new system

P23 03 Air Extraction System
Quick Start Exhauster Unit (Nash) Available
Condenser Exhausters Condenser Air Pumps not available Recommend new Nash air pumps
Including Silencer and air/water Separators
P24 02 Generator
Stator and Rotor Rotor to be repaired. Stator requires inspection Details - Part 2
Terminals & Main Connections Available
Slip Rings & Brushgear Available
Bearings 7 and 8 Bearing 7 Liner not available
Front and Rear Hydrogen. Seals New seals may be required
Front and rear End Shields Located in AB Annexe

22
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P24 03 Excitation Supply & Control Exciter and AVR - NOT Available. Recommend new equipment

P24 04 Generator Gas System
Hydrogen Control and Metering panels To be located
CO2 Supply To be located
HP and LP liquid Leakage detectors To be located
Gas Pressure Regulator To be located
Gas Analysis Equipment To be located
Pipework and Valves As available

P24 05 Seal Oil System Coolers not available

P24 06 Distilled Water System Coolers not available

P24 07 Stator Water System Coolers not available

P24 08 Generator Circuit breaker and Associated
Equipment

GCB (Red, Yellow & Blue Phases) Located in turbine hall Recommend refurbishment
Air Compressors (2 Off) Located in turbine hall
Air Receivers (2 Off) Located in turbine hall
Pipework and Valves As available
Local Control Panel As available

P24 11 Protection System (GSX5 etc) Not included

23
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P26 02 LP Feed System Will not include Pipework and Valves
Reserve Feed Water Tanks Located in Boiler House
Extraction Pumps (2 Off) Located in turbine hall Recommend refurbishment
Polishing Plant Equipment Including Vessel, Pumps, Resin Trap and Valves
Chemical Injection Pumps Not Available- used by Station
Drains Flash Condenser Recently moved outside
LP Heaters 1, 2 & 3 Recently moved outside
Flash Boxes and Flash Condensers Recently moved outside
Valves As Available
P26 03 Deaerator
Vent Condenser
Main Tank Part erected in Boiler house Could be removed and shipped
Steam Heating Coils
Pipework & Valves As Available
Local Control Panel As Available
Bled Steam Pipework and valves As Available
P27 02 Boiler Feed Pumps
Booster Pump Not Available.
Recommendation for new upgraded
Boiler Feed Pumps included in Part
2 of Report
Voith couplings to be refurbished
Motor Require refurbishment
Variable Speed Fluid Coupling Located in turbine hall and Shed 3
Main Pump Casings only Available
Control Panels and Instrumentation Available
Leak Off System valves Not available
Suction Valves and Strainers Not Available

24
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P28 02 HP Heaters 5, 6, and 7 and Associated Flash
Boxes


HP Heaters 5, 6, and 7 and Associated Flash Boxes
Available
Pipework and Valves As Available
Bled Steam Pipework and valves As Available
Control Panels As Available

Main Boiler Structure and Pressure Parts Part Ref. No. per Drawing B0006/1/25

P31 02 Structure
Boiler Girths and Support Brackets Items to be Identified Large quantity sighted in storage yard
Boiler Girths Attachments Items to be Identified Box 29 Shed 3
Casing, Cladding and Insulation Some casing panels may be available
Burner Corners 4 off
Galleries, walkways, ladders and stairs Not Included
Boiler Hanger Rods One Set
Roof Raft Steel Work Not Available (A large no. of hanger brackets etc seen) Items to be Identified
Header Support Brackets Items to be Identified
Superheater Element spacer bars Items to be Identified Additional req. for Seismic area
Access Doors - Bolt On 13 Off per Boiler - Listed Boxes for 2 units C8, C11,
C12, C18, C119, C20, C51, C55,
Access Doors - Welded On 46 Off per Boiler



25
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P31 03 Feed Water & Saturated Steam System
Feed Regulators and Associated Valves As Available
Inlet Feed Pipework As Available including pipe supports
Economiser Inlet Header Items not yet located
Bottom Bank Economiser Tubes 48 Elements per Boiler Economiser tube banks identified -
some fins damaged or broken
Top Bank Economiser Tubes 48 Elements per Boiler
Economiser Support Steel Work As Available for one Unit
Economiser Support Rods As Available for one Unit
Front and Rear Economiser Outlet Headers Headers H32 and H33
Economiser Riser Tubes Loose pipework
Economiser Top Collector Header Header H34
Econ. Header to Drum pipework Loose pipework
Main Steam Drum including Support Rods, Brackets, Washers etc.
Steam Drum Internals Not all Drum Internals Available Boxes C10, C42, C43,
Downcomers DC1- DC30 Note: Boiler 3 & Boiler 4 NOT Identical See Drawing B0006/9/1
Circulating Pump Manifold OK B0006/22/41
Boiler Circulating Pump Casings OK Recommendations included in Part
2 of Report
Boiler Circulating Pumps 3 Available - Recommend Refurbish
BCP inlet Isolating Valve and Associated
Pipework
As Available for one Unit
BCP outlet Isolating Valve and Associated
Pipework
As Available for one Unit Sections welded to valves
Link Pipework Outlet Valve to Distribution Drum CP3-CP6, CP9-CP12, CP15-CP18
Waterwall Bottom Distribution Header Items not yet located
Distribution outlet Pipework Items to be Identified

26
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P31 03 Furnace Floor Panels No. 65, 66, 67, 68
(contin
-ued)
Furnace Side Wall Header including Panel Section No. H2-H4 LHS and H6-H8 RHS
Furnace Side Wall Panels Section 'A' No. 5-8 LHS and 9-12 RHS
Furnace Side Wall Panels Section 'B' No. 20-23 LHS and 24-27 RHS
Furnace Side Wall Plain Tubes LHS, RHS, Front and Rear
Furnace Side Wall Intermediate Headers No. H1 LHS and H5 RHS
Furnace Front Wall Headers No. H9-H14
Upper Furnace Front Wall Section 'A' No. 51-56
Furnace Front & Deflector Panels Section 'B' No. 57- 60
Front Wall Hanger Tubes Plain Tubes
Front Corner Panel LHS No. 20/61
Front Corner Panel RHS No. 64/24
Rear Corner Panel LHS No. 41/23
Rear Corner Panel RHS No. 27/44
Lower Furnace Front Panels Section 'C' No. 61W, 62, 63, 64W
Furnace Rear Wall Headers inc Panel Section No. H15-18 I.e. Screen Tubes
Furnace Rear Panel Section 'A' No. 37-40
Furnace Rear Panel Section 'B' No. 41W, 42, 43, 44W
Burner Corner Panels 4 off
Integral Pipework To be Identified for One Unit Note: large quantity of integral and
loose pipework sighted not possible to
identify all under this contract.


27
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P31 04 Super Heater & Reheater System

1st Stage Superheater inlet Header Header 35
1st Stage Superheater Elements 24 Elements per Boiler 32 Elements identified
1st Stage Superheater Hanger Tubes To be identified
1st Stage Superheater outlet Header Header 36
1st Stage Superheater outlet Header Integral
Pipework
To be identified
Superheater Roof Tubes - Panels No. 45-50, and 31-36
2nd Stage inlet Headers H21 and H22 LHS; H23 and H24 RHS
Rear Wall Panels Section 'A' - Panels 13, 14 & 15
Rear Wall Panels Section 'B' - Panels 28, 29 & 30
Rear Pass Side Wall Section 'A' - Panels 1 and 2 LHS; 3 and 4 RHS
Rear Pass Side Wall Section 'B' - Panels 16 and 17 LHS; 18 and 19 RHS
2nd Stage Superheater outlet 'U' Header - Sections: H25, H26 LHS; H27, H28 RHS; H29, H30, H31 Rear Wall
3rd Stage Superheater Header Inlet Pipework 94 off Individual tubes - To be Identified
3rd Stage Superheater Inlet Header Header H37
3rd Stage Superheater 96 Elements per Boiler 154 Elements identified
4th Stage Superheater 96 Elements per Boiler 164 Elements identified
5th Stage Superheater 96 Elements per Boiler 134 Elements identified
5th Stage Superheater Outlet Header (2 Off) Header H38 and H39
5th Stage Superheater Outlet Header Pipework A and B Side
Superheater Attemperators A and B Side
6th Stage Inlet Header Pipework A and B Side
6th Stage Inlet Header Header H40
6th Stage Superheater Elements 48 Elements per Boiler 42 identified; currently short-fall of 6

28
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P31.04

6th Stage Outlet Header Header H41
(contin
ued)
6th Stage Outlet: Header to Stop Valve To be identified
Main Steam Pipework A and B Side Including Hangers
Reheater Inlet Header Header H42
Reheater Elements (96 Off) 96 Elements per Boiler 160 Elements identified
Reheater Outlet Header Header H43
Hot Reheat Lines A and B Side Including Hangers
Hot & Cold Reheat Lines A & B Side Including Hangers
P31 05 Boiler Mountings Not Included
Safety Valve Silencers Available Currently Installed on Roof
Blowdown Silencer Available Currently Installed on Roof
Safety Valve Expansion Boxes Available To be identified
P31 06 Drainage System & Valves
Pipework & Valves Not Included
Blowdown Tank Currently Not Included - being retained by Station
P31 07 Boiler Sootblowers Boxes Listed will cover Two Units
6th Stage Superheater/ Reheater Sootblowers 4 off C15, C76-C81; C85-108
Superheater Sootblowers 12 off
Economiser Sootblowers 12 off
Sootblowers support brackets and frames Total No. to be confirmed
Control Panels As Available
Guards No. per blower to be confirmed

29
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P32 02 Combustion Air System
FD Fans 'A' and 'B'
Motors Require inspection In shed 2
Inlet Vane Controls Incl. Hydraulic package Parts removed from Hyd. Package

P32 03 Gas System
GR Fans Not required for coal firing
GR Fan Motors
ID Fans 'A' and 'B' Rotors may need refurbished.
ID Fan Motors Require inspection In shed 2
Inlet Vane Controls Incl. Hydraulic package Parts removed from Hyd. Package

P32 06 Ignition Air & Flame Monitor
Purge System Fans (4 Off)
P33 02 Fuel Preparation System
LP Fuel Oil Filters (3 Off) Duplex Type
LP Fuel Oil Pumps (3 Off) 2 available
HP Fuel Oil Pumps Not Available
HP Fuel Oil Heaters (3 Off)
HP Fuel Oil Filters (3 Off) Duplex Type
P34 40 Instrument Air Supplies
Main Air Receiver Available Box C3
Air Dryers Not available would purchase with new compressor
Buffer Receiver Available Box C4
Compressors Not available

30
Plant
Ref
Plant Comments (1st Unit) Additional Comments
P35 02 LP & HP Wash Water Pumps Not available

P35 04 Boiler Filling Pump Available

P36 02 Steam Air Heaters (6 Off) Available

P36 03 Regenerative Airheaters
Stator
Elements Not Included.
Shafts & Bearings Available
Drive Assembly Pin racks missing on one unit
Hoods & Seals Seals not available Hoods need major refurbishment
Lub. Oil System
Sootblowers & Assoc. Seals Incomplete
Wash Water & Fire fighting

P49 26 Boiler House Lift 'B'

Ducts As Available and suitable for Coal Conversion

Supports, Hangers, Guides etc As Available

P60 Standby Diesel Generator One sold

P80 Hydrogen Plant Installed plant now redundant - Available

31
Turbine/Generator Packing List
TURBINE
SECT ITEM DESCRIPTION PER DRAWING/NO FR CASE LOCATION 3 4 LOCATION FR CASE
NO SET NO NO NO NO
AA 1 Assy No 1 Pedestal 1 36569 26981 Basement 1 1 Basement 38442 25670
AA 10 No 1 Pedestal parts 36569 26844 1 Basement 25671
AA 40 No 1 Pedestal parts 35554 26470 1 Basement 25671
AA 50 Packers, Nuts, Bolts Plates 26782/3 1 37894 25401
AA 94 Assy No 2 Pedestal 1 36620 26870 Basement 1 1 Basement 38296 25598
AA 95 Nuts, Pedestal 1 Basement 38276 25593
AA 97 No 2 Ped Parts 36037 26885 Basement 1
AA 100 Structural Bearings '' pallet 1
AA 115 Flexible conduit 36191 26998 1 1 Basement 38226 25604
AA 175 Heat shields 38256 25629 1 1 Basement 38257 25592
AA 191 Assy No 3 Pedestal 1 36730 26954 Basement 1 1 Basement 38993 25945
AA 193 Packers 1 Basement 37272 25167
AA 207 Crushing pegs 36730 26895 1
AA 227 Crushing pegs 1 Basement 38993 25951
AA 229 Parts No 3 Ped 1 38993 25089
AA 249 Bolts and dowels 1 Basement 37474 25960
AA 250 Pedestal items '' 26896 Basement 1 25960
AA 266 Assy No 4 Pedestal 1 36191 26871 1 1 Basement 38319 25614
AA 266 No4 Ped, Oil Catcher 1 37230 25169
AA 355 No1 ped cover assy 26927 1 1 Basement 38300 25596
AA 638 Ped cable 41250 28322 1
AA 1Q Emergency trip valve 36559 25335 Basement 1

32
AB 1 H.P. Inner Cyl Top Half 1 36534 26825 Basement 1 1 Basement 37870 25394
AB 5 H.P. Inner Cyl Bottom Half 1 36534 26826 Basement 1 1 Basement 37870 25395
AB 16 Centre gland HP Shaft 1 Basement 38066 25569
AB 25 Collar rod bolts, HP Gland 1 Basement 37870 25649
AB 34 Screws 36284 25079 1 25549
AB 41 H.P. Outer Cyl Top Half 1 36535 26819 Basement 1 1 Park 16B 38193 25545
AB 45 H.P. Outer Cyl Bot Half 1 36535 26818 Basement 1 1 Park 16B 38193 25546
AB 48 HP Outer Casing Bolts 36535 Fitted to cylinder 1 Fitted to cylinder
AB 66 Bolts Nuts Plates 25012 1 Basement 38193 25559
AB 102 Gland Carriages 0 26911 1 25557
AB 109 HP Half Sealing Ring 26911 1 Basement 41088 28323
AB 136 HP Inlet Pipe Top 1 37530 25505 Basement 1 1 Basement 40427 26624
AB 140 HP Inlet Pipe Bot 1 37530 25506 Basement 1 1 Basement 40427 26625
AB 142 Liner 1 Basement 40427 26626
AB 185 Lagging Guard Assy 1 Basement 38586 26239
AB 286 I.P. Inner Cyl Top 1 36311 26823 Basement 1 1 Basement 37855 25373
AB 286a I.P. Diaph Stg 2 to 5 36423 25218 Shed 3 1 1 Shed 3 38058 25577
AB 286b I.P. Diaph Glands 37471 25272 1 25577
AB 295 I.P. Inner Cyl Bot 1 36311 26824 Basement 1 1 Basement 37855 25376
AB 295a I.P. Diaph Stg 2 to 5 36422 25379 Shed 3 1 1 Shed 3 38058 25576
AB 300 I.P. Outer Cyl Top 1 36383 26816 Basement 1 1 Basement 37962 25479
AB 306 I.P. Outer Cyl Bot 1 36383 26817 Basement 1 1 Basement 37962 25480
AB 330 I.P. Carrier Ring Top Rear 1 36285 26829 Basement 1 1 Basement 37853 25369
AB 330a I.P. Diaph Stg 6 to 11 36422 25376 Shed 3 1 1 Shed 3 38065 26231
AB 330b I.P .Diaph Glands 37519 25271 1
AB 343 I.P. Carrier Ring Bot Rear 1 36285 26830 Basement 1 1 Basement 37853 25370
AB 343 I.P. Diaph Stg 6 to 11 36423 25219 Shed 3 1 1 Shed 3 38063 26230

33
AB 351 I.P. Carrier Ring top Front 1 36284 26827 Basement 1 1 Basement 37852 25371
AB 364 I.P. Carrier Ring Bot Front 1 36284 26828 Basement 1 1 Basement 37852 25372
AB 385 HP/IP CYL Parts bolts 36311 25080 1 Basement 37855 25483
AB 409 HP/IP CYL Jacking Screws 1 37962 25514
AB 411 HP/IP CYL Jacking Screws 36380 25026 Basement 1
AB 485 IP Gland Casing Front 1 Basement 37179 25640
AB 491 IP Gland Casing Centre 1 38179 25558
AB 567 IP Inlet pipe top 1 42605 25088 Basement 1 1 Basement 37478 25507
AB 576 IP Inlet pipe Bot 42605 25091 Basement 1 1 Basement 37478 25508
AB 615 Diffuser ring and screws 1 Basement 37336 25431
AB 001A H.P. Diaphs stg 1-9 top 36024 25385 Shed 3 1 1 Basement 37920 25575
AB 005A H.P. Diaphs stg 1-5 bot 36025 25164 Shed 3 1 1 Basement 37920 25605
AB 005F H.P. Diaphs stg 6-9 bot 36025 25168 Shed 3 1 1 Basement 37925 25607
AB 286A IP Diaph stg 2-5 36423 25218 Shed 3 1 1 Basement 38058 25577
AB 286B IP Diaph glands 37471 25272 1
AB 295a IP Diaph stg 2-5 36422 25379 Shed 3 1 1 Basement 38058 25576
AB 330a IP Diaph stg 6-11 36422 25376 Shed 3 1 1 Shed 3 38065 26231
AC 1 L.P. Inner - Cyl Top 1 37085 25022 Basement 1 1
AC 3 L.P. Inner - Cyl Bot 1 37085 25023 Basement 1 1
AC 5 L.P. Diaphs stg 1 37169 25386 1 1 Basement 38192 25555
AC 5a L.P. Diaph Glands 1 Basement 38658 25942
AC 7 L.P. Diaphs stg 1 37169 25387 1 1 Basement 38192 25556
AC 9 L.P. Diaphs stg 2 37170 25390 1 1 Basement 38182 25599
AC 10 L.P. Diaphs stg 2 1 Basement 38182 25600
AC 11 L.P. Diaphs stg 2 37170 25286 1 1 Basement 38182 25599
AC 13 L.P. Diaphs stg 3 37171 25287 1 1 Basement 38183 25601
AC 15 L.P. Diaphs stg 3 37171 25414 1 1 Basement 38183 25602

34
AC 27 L.P. Diaphs stg 4 37182 25284 1 1 Basement 38190 25627
AC 31 L.P. Diaphs stg 4 37182 25285 1 1 Basement 38190 25628
AC 33 L.P. Diaphs stg 4 37182 25368 1 Basement 25628
AC 35 L.P. Diaphs stg 5 37282 25340 1 1 Basement 38184 25625
AC 37 L.P. Diaphs stg 5 37282 25357 1 1 Basement 38184 25651
AC 39 L.P. Diaphs stg 5 37282 25341 1 1 Basement 38184 25626
AC 41 L.P. Diaphs stg 5 37282 25356 1 1 Basement 38184 25650
AC 52 Inspection cover lp hood 4 1 Basement 38771 25836
AC 54 L.P. Cyl parts 37085 25086 Site 1
AC 1B L.P. Diffuser top half 2 36988 26986/7 Site 1 1 Site
AC 3B L.P. Diffuser bot half 2 36988 26988/9 Site 1 1 Site
AD 1 '' Outer 2 Halves Top 2 34981 26259/60 Site 1 1 Site 25148/9
AD 7 Bracing Btm half end wall front 34853 26179 Site 1 1 Site 37213 25081
AD 9 Bracing Btm half end wall rear 34854 26180 Site 1 1 Site 37214 25082
AD 11 Bracing Btm half cross front 34820 26176 Site 1 1 Site 37117 25047
AD 13 Bracing Btm half cross rear 34821 26177 Site 1 1 Site 37118 25048
AD 17 L.P. Diffuser Ext Front 1 34786 26284 Site 1 1 Site
AD 19 L.P. Diffuser Ext Rear 1 34786 26282/83 Site 1 1 Site
AD 33 Explosion pot assy 4 36970 Loose 1 1 Site 40932 Loose
AD 37 L.P. Cyl Nuts and bolts 34981 26261 1
AD 39 Gland bolts 40510 28241 1
AD 41 Sealing Bellows L.P. 34750 25027 1
AD 56 LP Hood, Bolts and Nuts 1 Basement 37297 25150
AD 80 1 Basement 25109
AD 96 Guide pillars 26252 1 37238 25100
AD 124 L.P. Soleplate and washers 34965 26425 1
AD 142 Inlet Pipe Exhaust Chamber {2} 1 37212 25198/9

35
AD 143 Bellows 1 Basement 37212 25158
AD 144 35678 25013 1
AD 148 Joints 1 Basement 37706 25308
AD 206 1'90 O/D PIPE 37104 28174 1
AD 26 L.P. Sealing bellows F & R 1 37861 25659
AE 1 H.P. Rotor 36731 26903 Basement 1 1 Basement 38252 26066
AE 7 Coupling Bolts 26903 1 Basement 38169 25557
AE 27 I.P. Rotor 38500 28003 Basement 1 1 Basement 38618 26011
AE 33 Coupling Bolts 25603
AE 52 L.P. Rotor Basement 1 1 Basement 26384
AF 1 HP Stop valve l/hand 36320 25098 Basement 1 1 Basement 38509 25992
AF 3 HP Stop valve r/hand 36320 25099 Basement 1 1 Basement 38509 25991
AF 4 Steam Chest Cap 36320 26723 1 26239
AF 19 Distance Piece 1 Basement 41367 28513
AF 42 Duplex Thermocouples 38247 25603 1
AF 66 IP Steam chest l/hand 36384 25105 Basement 1 1 Basement 38895 26245
AF 69 IP Steam chest r/hand 36384 25106 Basement 1 1 Basement 38895 26246
AF 72 Jacking Screw 1 Basement 38895 25872
AF 88 Spring 1 41366 28514
AF 131 Spiral wound gasket 1 38507 25959
AF 165 Steam chest parts 36384 26784 1
AG 1 HP Stop v/v/ operate gear 1 38554 25812
AG 1e HP Stop v/v Lever l/hand 37091 25032 1 1 Basement 38375 25704
AG 5 HP Stop v/v Lever R/hand 37091 25032 1 1 38375 25705
AG 33 HP throttle Valve 37094 25071 1 1 38820 25711
AG 36 HP throttle Valve 37094 25072 1 1 38820 25878
AG 90 IP Stop valve lever 37092 25069 1 1 Basement 38849 25837

36
AG 94 IP Stop valve lever 37092 25070 1 1 Basement 38849 25838
AG 114 Bolt locking wire jacking screw 1 Basement 38849 25842
AG 122 IP Gov Valve Lever L / Hand
AG 129 IP Gov Valve Lever R / Hand
AJ 30 Bolts, gasket cover 38891 25859 1
AJ 39 Hinged Expansion Joint IP/LP 1 1
AJ 40 Hinged Expansion Joint IP/LP 1 1
AJ 73 BOLTS, GASKETS COVER 39324 26084 1 1 Basement 39325 26085
AJ 41 L.P. Crossover Pipes 1
AK 1 Lub oil system 35691 26515 1 1 Basement 26855
AK 4 Pipe assy 37600 25270 1 1 Basement 38212 25579
AK 24 DC Emer oil pump motor 26519 1 1 25715
AK 35 1 26838
AK 51 Motor - a/c flushing oil pump 35691 26518 1 1 Basement 36547 28238
AK 144 Lub Oil Strainers Brn 8,9,10 1 37047 25019
AK 146 36576 26847 1
AK 156 Tank, Lub oil system and Fan 34529 26013 1
AL 244 36601 26882 1
AL 498 SUPPORT RINGS 37146 25129 1
AL 488 IP, LP Cleading 37146 25130 1
BA 31 Drain Pot 1 35286 26427
BA 43 Water Level gauge 1 0 26524
BA 67 1 3/8'' Nuts condenser 42254 25087 1
BA 89 Bolts, Packers, Stiffeners 1 36760 26943
BA 99 Disperser Assy 36223 26684 1
BA 101 Air suction baffle 1 41103 28474
BA 102 Air suction baffles 35449 26440 1

37
BA 147 Drain Potts 1 34492 26512
BA 166 Backing Strip Gauge Glass 33813 26569 1 1 35636 26957
BA 168 Stiffeners, Condenser 40933 28240 1
BA 173 Condenser Flashbox 34308 25923 1 1 35809 26548
BA 180 35607 26489 1
BA 184 Standpipe Assy 1 35723 26527
BA 210 Condenser Tubeplate Inlet 4 33745 25618 1 1 Sold 35003 26290
BA 211 Condenser Tubeplate Outlet 4 33858 26227 1 1 Sold 34717 26198
BA 215 Inlet Waterbox NO 1 33745 25618 1 1 Site 36866 26848
BA 216 Inlet Waterbox NO 2 33858 26227 1 1 Site 36866 26847
BA 221 1 26949
BA 222 Tube Plate Joint 34926 26234 1 28323
BA 236 Outlet Waterbox NO 1 1 1 26925
BA 237 Outlet Waterbox NO 2 1 1 26926
BA 242 Condenser flashbox thermopockets 34983 26264 1 26829
BA 256 Condenser flashbox parts 26048 1
BA 258 Water Box support beams 4 33858 26227 1 1 34717 26198
BA 276 Gauge Glass and Joints, Studs 33712 25568 1 1 0 26387
BA 278 1/2'',3/4'' vent v/vs steam chest 40833 28129 1
BB 1 HP Heater No5 1 25858 Basement 1 1 Basement 26026
BB 21 H.P. Heater No5 Assor 1 Basement 35601 26483
BB 26 34168 25978 1 28069
BB 52 HP Htr flashbox parts 36170 26665 1
BB 52 Heater Waterlevel 1 26813
BB 64 HP Heater No6 1 25763 Basement 1 1 Basement 26027
BB 84 H.P. Heater flashbox No6 34260 25803 1 1 35600 26484
BB 127 HP Heater No7 1 26025 Basement 1 1 Basement 26417

38
BB 154 Standpipe assy 1 35553 28069
BC 1 L.P. Heater No 1 1 34535 26081 Site 1 1 Site 35306 26421
BC 31 Water level assy 37658 25299 1 1 37661 25300
BC 51 LP Heater No 2 1 34273 26082 Site 1 1 Site 35305 26422
BC 54 LP Heater Studs and Joints 1 35305 26411
BC 62 Standpipe assy 37104 28068 Basement 1
BC 63 Valves, Joints Bolts 35538 26463 1 1 35560 26476
BC 99 LP Heater No 3 1 34341 26083 Site 1 1 Site 35676 26511
BC 147 LP Heater No 1 Flashbox 1 34206 25805 1 1 35208 26377
BC 164 LP Heater No 2 Flashbox 1 34207 25806 1 35210 26378
BC 224 Chamber shell assy 1 37445 25240
BD 1 Drain flash Condenser 34378 26232 1 1 35555 26538
BD 17 I.P. Drain Flash Condenser 34235 25804 1 1 35209 26376
BE 1 Vent Condenser 31463 21067 1 1 35728 26539
BE 1 Deaerator shell 31463 21067 D/A Floor 1 1 D/A Floor 35728 26539
BE 31 DA Steam Heater 35584 26602/6 1 1 2 only 34042 25023
BE 37 DA Steam Heater Bolts 1 35584 25606
BE 64 DA Water level parts 33785 26088 1
BE 142 DA Header 1 35878 26574
BE 154 DA Header Assy 34164 26251 1 1 35878 26641
BE 165 DA Blank Flange 1
BE 181 Bottom packers 1 37952 loose
BE 289 D/A pipe, flanges, valve 37341 25214 1 1 37456 25212
BE 305 Valves and n/plates 37348 25182 1
BF 1 Gland Heater 34494 26562 1 1 35727 26563
BF 13 Standpipe Assy 35626 26494
BG 1 Rotary Air Pump No1 0 26354 1 1 Basement 26710

39
BG 3 Rotary Air Pump No3 1 26712
BG 4 34783 26178 1
BG 7 Ejector Bodies 26135 1 1 35905 26919
BG 18 Sealing Water Tank No1 35921 26686 1 1 36238 26690
BG 19 Sealing Water Tank No2 35921 26687 1 1 36238 26691
BG 20 Sealing Water Tank No3 35921 26688 1 1 36238 26689
BG 21 Gauge Glass and Studs 1 36238 26686
BG 22 screws Studs for tanks 35921 26660 1
BH 1 Condensate Strainer 34493 25590 1
BH 7 Joint 34493 25976 1
BH 15 HP Drain Vessel 34326 25885 1
BH 23 Joints, Nozzles Dispersers 1 26507
BH 34 IP Drain Vessel 34327 25886 1 1 35568 26482
BH 62 Disperser Assy 36229 26681 1
BJ 1 Main Oil Cooler No1 34063 25984 1 1 35232 26447
BJ 8 Main Oil Cooler No2 34063 25985 1 1 35232 26448
BJ 15 Main Oil Cooler No3 34063 25986 1 1 35232 26449
BJ 19 Vent valves and Plugs 1 35232 26371
BJ 56 Stator Water Cooler No1 34064 25740 1 1 35540 26454
BJ 64 Stator Water Cooler No2 34064 25741 1 1 35540 24455
BJ 68 Nameplates screws plugs 1 35540 26441
BJ 80 Distilled Water Cooler No1 34278 26228 1 1 25231 26452
BJ 86 Distilled Water Cooler No2 34278 26229 1 1 25231 26453
BJ 90 Distilled Water Valves & Screws 34273 25842 1
CJ 1 Extraction Pumps 2 Basement 1 1 Basement
CJ 5 Extraction Pump Motors 2 1 1
CM 11 Gland Steam Exhauster 2 1 AB Annexe

40
CN 7 Jacking oil pump 1 36798 26982 1 1 Basement 38259 25612
DA 1 Guide block 2 020/176001 20087 Basement 1 1 Basement 20177
DA 2 Guide block 2 020/176001 20088 Basement 1
DA 3 key 80mm thk 2 020/176001 20086 Basement 1
DA 18 packing 35mm thk 14 060/001300 1 Basement 20196
DA 24 h-bolt hex 2'76'' af 22 057/5003504 1 Basement 20179
DA 24 h-bolt hex 2'76'' af 22 057/5003504 20093 1
DA 29 Support clamp 1 024/018501 1 20186
DB 1 Stator c/w water manifolds 1 020/173001 20105 1 1 20171
DB 9 thermo board assy 1 045/020901 1 20214
DB 24 gas therm 4 777002801 1 20198
DB 31 drain hp 4 038b005601 1 20146
DB 78 Brg brk catcher 1 038b005601 1 20195
DC 1 e/shield 6 025/051301 20107 1
DC 50 e/shield 4 025/051301 20108 1
DC 73 hydrogen blower 1 20094 1 1 20185
DD 1 TOP HALF BRG BRK (TE) 1 039/119901 20140 1 1 20177
DD 2 BOT HALF BRG BRK (TE) 1 039/119901 20141 1 1 20176
DD 3 TOP HALF BRG BRK (SRE) 1 039/119801 20142 1 1 20174
DD 4 BOT HALF BRG BRK (SRE) 1 039/119801 20142 1 1 20175
DD 6 hex bolt m42 x110mm 72 039/119901 1 20191
DD 21 bolts and washers 4 039/119901 20153 1
DD 62 Brg brk cap 1 039/120101 20137 1 1 20194
DD 70 Brg bush compt with eye bolt 1 139/119701 1 20205
DE 1 terminal pockets 3 075x002501 1 20184
DE 4 adhesive 075x002501 1 20189
DE 13 terminals comp with 'o' rings 3 030/009902 20097 1 1 20180

41
DE 13 terminals comp with 'o' rings 3 030/009902 20098 1 1 20181
DE 15 terminals bush unions 12 030/009902 1 20181
DE 31 adhesive 5 031/x078001 20104 1
DE 37 grey enamel no6 031/078001 1 20187
DF 2 Dowels 2 042x007901 20116 1
DF 7 Conns assy 2 080/054101 1 20172
DG 1 Gland seal support 040/025001 20143 1
DG 2 Gland seal support 040/27001 20144 1
DG 73 Hyd blower 20094 1
DG 3448 Condenser trap v/v 20221 1
DG 3450 Condenser trap v/v 20223 1
DH 1 Rotor 1 002/182201 20154 1 1 20173
DH 3 Rotor Restriction Gauge 004/M004701 20134 1
DH 8 Carbon brush 2 62045/25002 20123 1 1 20121
DH 15 Conduit 20122 1
DJ 1 Coolers 2 000B232301 1 20178
DJ 5 Cooler plates 20112 1
DJ 20 Cooler pipe assy 1 053/008101 20109 1 1 20138
DK 1 SEAL OIL UNIT 20077 Basement 1
DK 10 Tank assy c/w valve and g/g 1 090/085501 20066 1
DK 10 Tank assy c/w valve and g/g 1 090/085501 1 20078
DK 13 L/L Detector assy 2 090M 086001 20110 1
DK 23 Gas dryer 1 000B223701 20085 1
DK 24 Control cubicle 1 000B223701 20084 1
DK 29 CO2 manifold 1 000B253101 20076 1 1 20079
DK 23A Air Reg c/w g/g 1 000B223701 20119 1 1 20120
EA 4 Eye bolts 4 138/002301 20082

42
EA 34 Packing 45mm thk 4 60983/005101 1 20113
EA 46 Guard Assy 1 62903m02590
1
20083 1

43
Major Plant Equipment List to complete a Unit

No Equipment Items / Package Available Number
available
Comments on Conditions (Original, refurbished,
repaired etc)
Turbo Alternators ( Detailing required for each
component)

1 Turbine
- HP, IP, LP stages, bearing, diaphragms, gland,
steam chest, valve gear
1
2 Generator 1
3 Stop and control valve 2 HP and IP
4 Governing Systems 0 Electronic Governor required
5 Actuators 8 Require refurbished/upgraded
6 AC Exciter 1 Requires major refurbishment. Static excitation
system recommended
7 Feed cycle heaters, piping
8 Boiler feed pumps
9 Condenser 1 Condenser shell opnly
10 Extraction pumps 2
11 Air ejector 0
12 Quick starting ejector 1
13 Drives for above pumps Nearly all available. All require inspection and
refurbishment
Boiler Plant ( Detailing required for each
component)

14 Primary superheater
15 Secondary superheater

44
No Equipment Items / Package Available Number
available
Comments on Conditions (Original, refurbished,
repaired etc)
16 Final superheater
17 Reheater primary
18 Reheater secondary
19 Economiser
20 Desuperheater
21 Boiler circulating pumps 3 Require upgrading
22 Main air preheater Suggest new air heaters purchased.
23 Steam airheater Available
24 Fuel oil burners
25 FD fans and drives 2
26 ID fans and drives 2
27 Gas recirculation fans Available but not required for coal
28 Soot blowers
29 Soot blower air compressors Steam sootblowers
30 Auxiliary boiler plant items Available but not recommended
31 Unit dosing equipment Not available
32 Fuel oil heaters Not available
Fuel Oil System
33 Tanker hose handling system
34 Storage tank
35 Oil filters
36 Transfer pumps
37 HP fuel pump
38 Steam heating set for HFO

45
No Equipment Items / Package Available Number
available
Comments on Conditions (Original, refurbished,
repaired etc)
Cranes
39 Turbine hall 0
40 Workshop 0
41 Boiler house 0
42 Cooling water pumphouse 0
43 Boiler feedwater pumphouse 0
44 Cooling water screen 0
45 Feed oil pumphouse 0
Transformers
46 Generator transformer 0
47 Unit transformer 1
48 Auxiliary transformer 0
Switchgear
49 11 kV air break 0
50 3.3 kV air break 0
51 Generator load switch 3
52 Stand-by diesel plant 0
53 Fire protection pump 0
54 Fire fighting installation 0
55 Smoke Detection System 0
56 Instrument air compressor and drive 0
57 Service air compressor and drive 0
58 DCS system 0
59 I&C system 0

46
No Equipment Items / Package Available Number
available
Comments on Conditions (Original, refurbished,
repaired etc)
Other Equipment
60 Starting Power (Diesel Set) 0
61 Hydrogen generation plant 1
62 Cooling water pumps and drive 0
63 Chlorination plant 0
64 Demineralised water plant items 0
65 Make up water treatment plant 0
66 Condensate polishing plant 1
67 Specialist lifting tools and equipment 0
Structure
68 Steel structure for boiler 0
69 Steel structure for turbine 1
Documentation
70 Calculations May be available
71 Erection plans and drawings Original plant microfilms may be available
72 Materials certificates Items available
73 NDT information
74 Miscellaneous other information
75 Coal Conversion documents, drawings, conditions
to acquire proprietary information
May be available for Unit 3 & 4 project
76 Test certificates for Boiler and high pressure
components from Govt. inspecting agencies
May be available


47
Electrical and C & I Equipment

No Equipment Items / Package Available Number
available
Comments
Control and Instrumentation
1 Unit desk 0
2 Unit recorder panel 0
3 Unit sequence equipment 0
4 Unit alarm system 0
5 Auto boiler control cubicle 0
6 Unit marshalling cubicles 0
7 Control room marshalling cubicles 0
8 Desk marshalling cubicles 0
9 Main unit governor 0
10 Main boiler feed pump governor 0
11 Turbine & main boiler feed pump turbovisory
panel
0
12 Main boiler feed pump overspeed cubicle 0
13 Unit start up and interlock cubicles 0
14 Boiler interlock cubicles 0
15 Boiler hydrastep system 0
16 Turbine water ingress panel (feed system
protection)
0

48
No Equipment Items / Package Available Number
available
Comments
17 Fast closing valves and NRVs 0
18 Local plant instrument panels and gauge panels 0
19 Main oil burner control cubicles and actuators 0
20 All unit system valve actuators and dampers 0
Switchgear:
11 kV Unit Board 0
21 Forced draft fan A cubicle 0
22 Forced draft fan B cubicle 0
23 Induced draft fan A cubicle 0
24 Induced draft fan B cubicle 0
25 50% boiler feed pump cubicle 0
26 Start up boiler feed pump cubicle 0
27 Cooling water pump cubicle 0
28 Diesel plant cubicle 0
29 Unit transformer cubicle 0
30 Unit auxiliary transformer cubicle 0
31 Interconnector 0
Breakers
32 Forced draft fan A 0
33 Forced draft fan B 0
34 Induced draft fan A 0
35 Induced draft fan B 0

49
No Equipment Items / Package Available Number
available
Comments
36 50% boiler feed pump 0
37 Start up boiler feed pump 0
38 Cooling water pump 0
39 Gas turbine 0
40 Unit transformer 0
41 Unit auxiliary 0
42 Interconnector 0
3.3 kV Board:
43 Gas recycling fan A cubicle 0
44 Gas recycling fan B cubicle 0
45 Direct contact heater extraction pump A cubicle 0
46 Direct contact heater extraction pump B cubicle 0
47 Start up air pump A cubicle 0
48 Start up air pump B cubicle 0
49 Condensate extraction pump A cubicle 0
50 Condensate extraction pump B cubicle 0
51 Main fuel oil pump 5 cubicle 0
52 30% make up pump cubicle 0
53 Unit auxiliary transformer cubicle 0
54 Unit station transformer cubicle 0
Breakers
55 Gas recycling fan A 0

50
No Equipment Items / Package Available Number
available
Comments
56 Gas recycling fan B 0
57 Direct contact heater extraction pump A 0
58 Direct contact heater extraction pump B 0
59 Start up air pump A 0
60 Start up air pump B 0
61 Condensate extraction pump A 0
62 Condensate extraction pump B 0
63 Main fuel oil pump 0
64 30% make up pump 0
65 Unit auxiliary transformer 0
66 Unit station transformer 0
67 Condensate extraction pump 5B 0
68 Main fuel oil pump 0
415 V Services Board:
69 All circuits 0
415 V Essential Services Board:
70 All circuits 0
415 V Instrumentation Board: 0
71 All circuits 0
240 V DC Unit Services Board: 0
72 All circuits 0
240 V DC Unit Instrumentation Board: 0

51
No Equipment Items / Package Available Number
available
Comments
73 All circuits 0
110 V DC Unit Services Board 0
74 All circuits 0
0
Transformers
75 23.5/??? kV Generator, ???? MVA 0
76 17/11 kV unit, ?? MVA 1
77 11 kV / 415 V unit essential services 0
78 11/3.3 kV unit auxiliaries 0
79 3.3 kV/415 V unit services 0
80 Earthing transformer 0
Alternator Train
81 Generator Stator 1
82 Generator Rotor 1
83 Main exciter rotor and rotating rectifier 1
84 Main exciter stator 1
85 Pilot exciter stator 1
86 PMG Rotor 1

You might also like