You are on page 1of 13

DESIGN OF A CANTILEVER

this color shows the data entry cell

DATA
bearing capacity
Fc'

4.2 ksf
3 ksi

Fy

60
4.1
0.55
110
30
150

wall height

concrete
DIMENSION OF WALL
wall height
base width
toe width
heel width
stem thickness
base thickness

4.1
9.8
2.2
6.8
0.8
2.5

ACTIVE COEEFFICIENT
Ka

0.333

ft
ft
ft
ft
ft
ft

ksi
ft
lb/ft

lb/ft

0.524 rad

3000
675
2075
250
760

PRESSURE
148.867 lb/ft

FOR LATERAL SOIL PRESSURE


P1
0.302 Kips
MOMENT
Mot
0.409 kips-ft

TYPE

LOAD (lb/ft)

X(A) ft

MOMENT(A)

W1 (stem)

192.7364235

2.624672

505.8698941

W2 (foundation
load

3681.257598

4.92126

18116.42577

W3 (soil load)

1173.122364

6.4386485

7553.322551

mm
mm
mm
mm
mm

W
5047.116386

M
26175.61821

SLIDING:

FOS

9.186 WALL DESIGN IS SAFE

OVERTURNING MOMENT

FOS

64.003 WALL DESIGN IS SAFE

BEARING CAPACITY

5.105220449 ft

CHECK FOR PURE COMPRESSION


B/2
4.92126
B/6
1.64042
eccetricity
-0.18396045 <

B/6
PURE
COMPRESSION
Pmax
Pmin
Pmax

0.455
0.570
<

CANTILEVER WALL

0.82

W3
W1

4.06

2.21

6.81
W2
9.84

2.49

Pmin
Pmax

0.570
0.455
ksf

ksf
ksf
bearing capacity

WALL DESIGN IS SAFE

ksf

STEM DESIGN:

1.566562

W1
2.214567
2.493438
from check sheet
Ka
0.333333
Pa

148.8667 lb/ft

9.84252
at base of footing

PMAX
0.455282

max Pa for stem


Pa

57.44059 lb/ft

lateral pressure
Ha
0.044992 kips
shear force
Vu
0.071987 kips
check for one way shear
Vc
40.87555 Kips

MOMENT
Ma

>
0.071987 kips
the section is adequate in one way shear

0.023494 kip-ft

factored moment
Mu
0.037591 kip-ft
for As

on solvinig quadratic equation for As


a
0.052941
b
-1615.75
c
0.451091

As1

2
30519.69 in

As2

2
0.000279 in

from table A14 of nadeem hassoun


use #4 bar spaced at 8" (0.29 in2)

DESIGN OF TOE:
Critical section exist at a distance "d" from the face of stem
d=
26.92126 in
at "d" the soil pressure would become
p=
0.454945 ksf

2.493438

0.455282

for Vc
Vc
for Vsoil
Vsoil

-0.00433 kips
-0.0131 kips

for factored shear

Vu

-0.0088 kips
DESIGN STRENGTH
Vc
31.85002 kips

MOMENT
Mc

-0.0048 kip-ft

Ms

1.116145 kip-ft
FACTORED MOMENT

MU

1.78871 kip-ft

for As

0.052941

>
-0.0088 kips
the section is adequate and no shear r/f is required

b
c

-1453.75
21.46452

As1

2
27459.67 in
2
0.014765 in

As2

2
use As=
0.014765 in
from table A14 of nadeem hassoun
use #3 spaced at 6.5" (0.20 in2)

DESIGN OF HEEL:

For Vc
VC

0.75 kips

For Vsoil pressure


Vsoil pressure

6.00275 kips
1.5261

For Vsoil
Vsoil

0.861609 kips

For factored shear

Vu

-2.52363 kips

DESIGN STRENGTH
Vc

6.83052 kips

MOMENT
MC

1.875 k-ft

>

-2.52363 kips
the section is adequate

Msoil

2.154022 k-ft

Msoil pressure 13.65042 k-ft


FACTORED MOMENT

MU

-5.2239 k-ft

for As

a
b
c
As1
As2

0.635294
-270
-62.6868
2
425.232 in
2
-0.23205 in

2
use As=
-0.23205 in
from table A14 of nadeem hassoun
use #6 spaced at 7.5" (0.71 in2)

0.82021

W1

4.06
6.807743
W2

9.84252
Pmin
0.570292

Vc
2.214567

26.92126 in
0.481159 ksf
0.454945 ksf
Vsoil

Vsoil

VC
5

0.875
Vsoil pressure