You are on page 1of 8

SKF 728619

Hydraulic Pump
Instructions for use
EU-DECLARATION OF
CONFORMITY FOR MACHINERY
We, SKF Maintenance Products BV, Constructieweg 7, 3641 SB
MIJDRECHT, The Netherlands, declare that this
HYDRAULIC PUMP
728619
is designed and manufactured in accordance with the Directive by the
Council of the European Communities of 14 June 1989, amended 20
June 1991, 14 June 1993 and 22 July 1993, on the approximation of
the laws of the Member States relating to machinery.
The Netherlands, 1 January 1995
Magnus Rydin
Manager Product Development and Quality
Table of contents
Page
Safety recommendations . . . . . . . . . . . . . . . . . . . . . 4
1. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3. Operating instructions . . . . . . . . . . . . . . . . . . . . . . 6
4. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1 Replacing the oil . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Cleanliness . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.3 Replacement parts . . . . . . . . . . . . . . . . . . . . . . 7
728619 3
Safety recommendations
As high pressures constitute a potential safety risk, the following
instructions must be considered:
The equipment should only be operated by trained personnel.
Always follow the operating instructions.
Check the pump and all accessories carefully before use. Never
use even slightly damaged components.
Make sure all air has been removed from the hydraulic system,
before pressurizing the pump.
Always use a pressure gauge.
Always prevent the workpiece/tool from being projected upon
sudden release of pressure (e.g. by use of retaining nut).
Never use the equipment above the stated maximum pressure.
Never adjust safety valves to work at pressures above the
maximum working pressure.
Do not extend the handle in order to reduce the required force to
reach maximum pressure. Use hand pressure only.
Never use the pump together with accessories which are rated
below the maximum pressure of the pump.
Use protective goggles.
Never modify the unit.
Use original parts only.
Only use clean, recommended hydraulic oils (e.g. SKF LHMF 300,
LHDF 900 or similar).
In case of any uncertainties as regards the use of the pump,
contact SKF.
4 728619
1. Description
The 728619 is a two-stage pump giving a high flow (17,5 cm
3
per
stroke) until the switching pressure is reached. From then on the flow is
automatically reduced to 1,25 cm
3
per stroke.
The pump is supplied with a 3 metre long high pressure hose with quick
connection coupling and a 1/4" quick connection nipple for attachment
to the workpiece.
The pump is filled with SKF mounting fluid LHMF 300 and comes with
an additional 1 litre can with LHMF 300. Everything is packed in a sturdy
case.
The pump has two different outlets for double jacking and an extra
return connection into the oil container. This return can also be used for
connection of an extra oil reservoir when the oil container capacity is
insufficient.
The release valve is designed as a part of the pump head. The pump is
equipped with a safety valve for protection against over-pressure.
Extra outlet
Extra retun
to container
2. Technical data
Maximum pressure : 150 MPa (21.750 psi)
Volume per stroke : 17,5 cm
3
(1,1 in
3
) below 2,5 MPa (362 psi)
: 1,25 cm
3
(0,08 in
3
) above 2,5 MPa (362 psi)
Oil container capacity : 2.300 cm
3
(140 in
3
)
Pressure hose : 3 m long with quick connection coupling
Connection nipple : 1/4" G, external or internal thread
Oil viscosity mounting fluid: 300 mm
2
/s (1.400 SUS) at 20C (68F)
Weight (filled with oil) : 12 kg (26 lb)
Designation : 728619
728619 5
3. Operating Instructions
a) Check oil level by unthreading the container plug under the pump
handle. Make sure there is enough oil for your complete operation.
For mounting bearings with the SKF Oil Injection Method, or by
means of an hydraulic nut, we recommend an oil viscosity of
approximately 300 mm
2
/s (1.400 SUS) at operating temperature.
For dismounting bearings, we recommend an oil with a viscosity of
900 mm
2
/s (4.100 SUS) at operating temperature.
b) Hold the pump horizontally or slightly tilted forwards in order to
secure oil supply.
c) Close the release valve on the right hand side of the pump without
using force.
d) Screw the quick connection nipple (1/4" G) into the workpiece.
e) Connect the hose to the nipple by withdrawing the snap-ring on the
quick connector. The hose is disconnected in the same manner.
f) Continue pumping until necessary pressure is reached for your
application. Maximum pressure is 150 MPa (21.750 psi) at which
pressure the safety valve will open.
g) Open the release valve, letting superfluous oil return to the oil
container.
Filler plug
Open
Closed
Release valve
4. Maintenance
4.1 Replacing the oil
When replacing the oil or after maintenance, make sure no air is trapped
in the system. This should be checked before attaching the hose to the
application, by making sure only air-free oil comes out of the hose when
pumping. Only use clean, recommended hydraulic oils.
4.2 Cleanliness
Keep the pump clean from dirt and metal particles in order to avoid
excessive wear.
6 728619
4.3 Replacement parts
Designation Description
728619-1 Pump
728619-1A Spring set complete
728619-2 Transport box
728619-3 Pressure gauge assembly
728619-4 Seal nipple
728619-5 Filler plug assembly
728619-6 Pump head assembly
728619-7 Repair kit
728619-8 Handle holder (complete)
728619-9 Release valve
728619-10 Container shaft
729831 A Quick connection coupling
729832 A Quick connection nipple
729834 High pressure hose
LHMF 300/5 Mounting Fluid (5 litre, 300 mm
2
/s at 20C)
LHDF 900/5 Dismounting Fluid (5 litre, 900 mm
2
/s at
20C)
728619 7
In line with our policy of continuous development of
our products we reserve the right to alter any part of
the above specification without prior notice.
SKF Maintenance Products B.V.
Copyright SKF 1996
M
P
5
0
1
E
/
9
6
0
7

You might also like