Professional Documents
Culture Documents
Devices
EPLAN Training
Devices
2.2
2.3
Delete entries............................................................................................8
Placing Devices...........................................................................................10
3.1
3.2
3.3
4.2
EPLAN Training
Devices
EPLAN Training
Devices
2. In the Function template tab define a function template for every function in
(New).
the device: To do this, click
A new row is created in the table.
3. In the first cell, use [...] to open the function selection and select a function
definition.
EPLAN Training
Devices
4. Click [OK].
5. Enter the technical data of the function into the other cells on the Function
template tab.
6. In the Special group box, you can allocate a symbol and technical data to the
part.
The symbol is placed when no function templates exist, i.e. the table is
empty.
If function templates exist, then the data entered here is not accounted for,
but you can still use this for filtering.
7. Click [Apply].
The device definition is stored in the part.
EPLAN Training
Devices
Precondition:
You have opened a project page.
Project data > Devices / parts > Device list
2.1
Create entries
You have two ways of inserting parts into the device list: Either insert a part using the
part selection, or create a new part directly in the device list.
Popup menu > Add part
1. In the Part selection dialog select the desired part.
EPLAN Training
Devices
2. Click [OK].
The part is added to the device list with the permitted unit quantity of "1".
2. In the Number allowed field enter the number of these parts that may be used
in the project.
EPLAN Training
Devices
3. In the System part and Device description field, enter the installation
requirements and a description of the functionality of the part. The device list
can be sorted according to these descriptions by clicking the column headers.
4. Click [OK].
The part is added to the device list with the permitted unit quantity.
2.2
Edit entries
Precondition:
You have selected a part in the device list.
Popup Menu > Properties
1. If required, in the Properties <...> dialog, change the values in the Part
number, Number allowed, System part, and Device description fields.
All other fields are automatically filled and can't be changed.
2.3
Delete entries
Precondition:
You have selected a part in the device list.
EPLAN Training
Devices
Popup menu > Delete
The selected parts are deleted from the device list. This has no effect on the
placement of the relevant part. It merely means that the relevant part is no longer
monitored.
This functionality is only available for certain module packages. Info
EPLAN Training
Devices
Placing Devices
Devices can be placed from the device list, graphical editor, or the navigators.
Placing devices in the schematic is a quicker way of connecting devices to parts than
the customary procedure of symbol placement with subsequent part selection.
Preconditions:
You have opened a page in the graphical editor.
You have entered a symbol or macro for the part in the parts management, or
3.1
EPLAN Training
10
Devices
3.2
EPLAN Training
11
Devices
2. Select Popup menu > Place > Multi-line.
The symbol or macro assigned to the part hangs on the cursor.
Tip:
You can placed devices using drag and drop, by dragging a selected device from the
navigators onto your opened page in the graphical editor.
EPLAN Training
12
Devices
3.3
Delete placements
Precondition:
You have opened a page in the graphical editor.
1. Select a component and then select the menu item Edit > Delete placement.
The graphical representation of the function in the circuit diagram will be
deleted. The function and its data remain in the database as an unplaced
function and can, for instance, be placed again from the device navigator.
EPLAN Training
13
Devices
In the device list, you have the option of placing a device immediately with its
corresponding parts data. If no symbol or macro is assigned to the part, use the
symbol or macro selector to select and place a symbol or macro. Or you can select a
function using the function selector and place the corresponding symbol.
Preconditions:
You have opened a page in the graphical editor.
You have entered a symbol or macro for the part in the parts management, or
4.1
EPLAN Training
14
Devices
2. Select Popup menu > Place via > Parts data.
The symbol or macro defined for the part in the parts management, hangs
on the cursor.
EPLAN Training
15
Devices
4. Place the further functions of the device, or cancel the process using Edit >
Cancel action.
If you place all the functions of a device sequentially, then the "Acquire DT
from left" is also accounted for in the process.
4.2
2. Select Popup menu > Place with and subsequently a menu item from the
submenu: Function selection, Symbol selection, or Macro selection.
Depending on your selection, the function selection, symbol selection or
macro selection dialog will be opened.
EPLAN Training
16
Devices
3. Select the desired function, symbol or macro and click [OK].
The symbol hangs on the mouse pointer.
Tip:
You can placed devices using drag and drop, by dragging a selected device from the
device list onto your opened page in the graphical editor.
EPLAN Training
17
Devices
EPLAN Training
18