You are on page 1of 2

PATENT OFMINI-BREAKER

MANAGEMENT

Promov Guarantees Safety


XIAMEN TAIHANG TECHNOLOGY CO.,LTD

Smart Auto-Recloser for Miniature


Circuit Breaker & RCD or ELCB

Surge Solution Engineering Sdn Bhd (836303-K)


L-01-05, Block L, Jalan PPK 1, Persiaran Kinrara Section 3,
Taman Kinrara, 47100 Puchong, Selangor Darul Ehsan, Malaysia
Tel/Fax No: +603-6274 1818
Mobile: +6012-3456 181
Email: surge.solution@gmail.com surge.solution@gmx.com

Low power consumption

Remote computers
can control reclosing

Dry contact can send out


warning signal

Shift between manual


and automatic

MCB Automatic reclosing

Setting reclosing conditions

Setting reclosing times

Setting reclosing time interval

Can be matched with single-phase,


three-phase MCB and RCD of
different manufacturers

Smart Auto-Recloser for Miniature Circuit Breaker & RCD


T27 smart auto-recloser for MCB or RCD is developed to solve the problem
that the system is unable to work normally after unmanned power supply
device-trips, or the system losses lightning protection after the MCB or RCD
installed in the unmanned mobile base station trips. T27 smart auto-recloser for
MCB or RCD enables the lightning protection device of mobile base station,
unmanned power supply system to reclose automatically in a short time. This
device can achieve the unmanned aim.
T27 smart auto-recloser for miniature circuit can be combined with standard
module MCB made by different countries to constitute reclosing mechanism. It is
suitable to be used in telecommunication, electric power, mobile base stations and
other fields in the countries all around the world.

T27-MA Auto-Recloser for 3P MCB

Close automatic reclosing function

4
2

T27-MA Auto-Recloser for RCD or ELCB

Start automatic reclosing function

Smart Remote Control


T27 can send its status information to the central control room through RS485
communication protocol. Under the situation that it needs to cut off power occurs,
users can take remote control through computer. When the number of continuous
reclosing exceeds the maximum reclosing numbers because of electricity accidents
or lightning accidents, users can also conduct reclosing operation, realizing
intelligence and monitoring. It effectively protect equipment from being ineffective.

Promov Guarantees Safety

T27-MA Specifications

Digital display

Paramters for the power source of T27-9V


Input voltage

150-300V/ac

Manual/automatic
control switch

Operating supply voltage

DC 8-28V/1A

Power consumption

Static state:<0.1W

Time of reclosing

T<2S

Output voltage

DC 9V/1A

Times of operating mechanism

>20000

Ripple voltage

<100mV

Operating ambient temperature

-25C~60C

Operating ambient temperature

-25C~60C

Storage ambient temperature

-40C~75C

Storage ambient temperature

-40C~75C

Working ambient humidity

20%~90%

the standard of rail installation

EN60715(35mm)

Control cable

Input: 0.75-1.2mm

Protection grade

Terminal: IP20

Status display

Green indicator

Reclosing
lever

Output: 1.5mm

Control
signal port

dynamic state:<3W

working ambient humidity

20%-90%

Remote opening/closing control

Control switch on/off<2s

Times of reclosing

Defaulting 3 times(can be set from 0 to 99 times)

Time interval of reclosing

Defaulting 5s(can be set from 0 to 99 times)

The standard of rail installation

EN60715(35mm)

Length of control cable

Control switching-in and switching-off cable:<1500m

Protection level

Connecting terminal:IP2X

Signal state display

1NO+1NC change-over dry contact 1A(230V)

Bus communication

RS485 transmission distance:<1000m

recloser:IP4X

You might also like