You are on page 1of 26

CORETEST SYSTEMS, INC.

Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

CAG-600
Computer Aided Goniometer
The CAG-600, Computer Aided Goniometer, is an instrument for digitizing and documenting planar or linear
features in core samples such as bedding, fractures
and stylolites. The goniometer consists of the core digitizer, serial interface box and connection cable. Complete software is supplied with the goniometer for data collection and report analysis. The computer can be
supplied by Coretest Systems, or provided by the customer. The digitizer consists of a base plate, two rubber
rollers to place the core on, and several linear and rotary encoders which are used to monitor the position of a
stylus arm. The stylus is placed on the planar feature at several points on the feature and the program automatically calculates the orientation relative to the scribe line. An optional roller support is used to support
longer core samples. If the core sample is from a non-vertical or deviated well the dip and azimuth of the well
can be entered as a function of depth. The program automatically corrects for the deviation on the collected
data. Orientation and description data are stored in the main file called the well file. Data are collected in the
segment level. For each segment the user characterizes the sample depth, orientation of feature, and de-

Features

Specifications

Core length:

Computer:
Pentium processor required, SVGA graphics,
50 MB minimum hard drive space and have a
9 pin serial interface connector

2 to 12 inches (5.08 to 30.48 cm) standard,


up to 4 feet with optional support stand

Core diameter:
2 to 6 inches (5.0 to 15.0 cm)

Resolution:
Accuracy:

<0.5 degrees

0.5 degrees

Approximate dimensions (inches):


(Width x Depth x Height)
17 x 13 x 8
Options:
Roller Support for long cores
Computer and printer
Specifications subject to change without notification.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

AERS-702
Ambient Electrical
Properties System
A suite of bench top devices that enable a user to measure ambient condition electrical properties of core plug samples. Properties that can be determined include Formation Factor, Resistivity Index, and Saturation Exponent "n". With the addition of an
overburden coreholder the Cementation Exponent "m" can also be determined at
ambient temperature.
Features

Specifications

Enables benchtop measurements of Formation Factor and


Resistivity Index at ambient conditions.

System Includes:
Ambient Measurement Properties Cell (AEP-97), DRM-98
Digital Resistance Meter, 2-4 terminal switch box with temperature indicator, brine resistance measurement dip cell and
Excel spreadsheet templates for calculating parameters
(Excel program is available as an option)

System includes equipment for both rock and brine resistivity


measurements
Calibrate well log data from measurement of Cementation
Factor m and Saturation Exponent n
Standard cell offers 2 contact measurements.

Fluid Media Compatibility:


All gases and liquids compatible with materials of construction

Four terminal sleeve adapters are available for 1, 30mm and


1.5 diameter cores

Standard Sample Sizes Accommodated:


Plug size: 1.0, 30mm, 1.5
Length up to 3 inches

Silver membranes insure good electrical contact for accurate


measurements
BNC connectors easily adapt to DRM-98 Digital Resistivity
Meter and most other resistance meters
Computer data acquisition system for automatic collection of
resistance data
Plastic cover box included to prevent core drying out during a
measurement

Standard Pore Wetted Materials:


Stainless steel, glass, silver, plastic
Optional Accessories/Kits:

4-Terminal Sleeve/Connector Kit

ABRC-20 Ambient Brine Resistance Cell (flow


through type)

Computer data acquisition system

GCS-765 Gravimetric Capillary Pressure System for


desaturation of core plugs

URC-628 or CENT-635 Centrifuge for sample desaturation


Specifications subject to change without notification.

Pneumatic loading for accurate and repeatable resistance


measurements
The 4-terminal option enables resistance measurements at
precisely spaced increments and is available for several core
diameters.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

OEP-705
Overburden Electrical
Properties System
The OEP-705 includes a coreholder, fluid flow accumulator, confining pressure pump, and all
necessary components to confine a core sample, flow brine for ionic equilibrium, and allow 2 and/or
4-terminal connection to the core sample for electrical property measurements using an appropriate
measurement device such as the DRM-98 LCR meter (not supplied). Capability for desaturation
using gas or oil through a semi-permeable ceramic plate while in the coreholder is also included with
the OEP-705 when the optional capillary pressure desaturation kit is ordered.

Features
Enables benchtop measurements of Formation Factor and Resistivity Index at
elevated overburden pressures
Calibrate well log data from measurement of Cementation Factor m and
Saturation Exponent n
Standard cell offers 2 contact measurements. Four-terminal sleeves are available upon request
Silver membranes insure good electrical
contact for accurate measurements
BNC connectors easily adapt to DRM-98
and most other resistance meters
Includes a digital temperature measurement display
Computer data acquisition available

Specifications
Standard Confining and Pore Pressures:
Plug size: up to 9,950 confining, 9,500 or 5000 pore
pressure
Standard Sample Diameters Accommodated:
Plug size: 1.0, 1.5 (30mm available)
Length range: 0.75 to 4
Includes:
Core holder and support frame, DRM-98 Digital Resistance Meter, Confining pump and gauge
Fluid Media Compatibility:
All gases and liquids compatible with materials of construction
Standard Pore Wetted Materials:
316 Stainless Steel / Viton / Silver
Optional Pore Wetted Materials:
Hastelloy and Titanium
Optional Accessories/Kits:
4-Terminal Sleeve/Connector Kit
Capillary Pressure Desaturation option, including bladder accumulator, precision pressure
regulator and produced fluid cell
Computer data acquisition system
Brine Resistivity measurement cells
Specifications subject to change without notification.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

GCS-765
Gravimetric
Capillary Pressure System

Single Cell

This Gravimetric Capillary Pressure Measurement System offers a precision instrument for the desaturation of core samples by the porous plate method up to 200 psi. The measured data can be utilized to calculate Capillary Pressure versus
Saturation curves and tabular data, Height above free water zone, pore size distribution, and water cut versus height.
The data can also be utilized to aid in the determination of wettability and relative permeability characteristics. A Microsoft Excel computer spreadsheet template is included along with manual data sheets for data collection and calculation.
The 200 psi chambers included with this system can hold up to 20-one inch diameter samples at a time. The maximum
sample height is 6 inches enabling desaturation of full diameter samples as well as plugs.
A precision gravimetric weighing balance is required in order to make sample saturation determinations (Balance available as an option). The system can be configured with from one to five desaturation chambers. Each chamber utilizes a
dedicated rack mounted pressure selection module. Each pressure selection module utilizes 2 digital pressure transducers (0-15, 0-250 psi) with accuracy's of 0.11%. Pressure transducers with 0.05% accuracy are available upon request.
Gas humidifiers are included to insure minimum evaporation during the desaturation process. Multiple precision pressure
regulators enable accurate pressure control down to 1/4 of an inch of water. (0.01 psi)

Features

Specifications

CORRELATION OF CONNATE WATER SATURATION


vs PERMEABILITY & HEIGHT

CAPILLARY PRESSURE VS. BRINE SATURATION

Date: 2/2/93
Test/Job I.D.: Example2

100

Date 2/2/92
Test/Job I.D.: 92112

40

35
1
30

Height, feet
9
13.5
18.1
22.6

10

27.1
Series7
Series8

3
Capillary Pressure, psi

Permeability, millidarcies

4.5

25

Power / Utilities:
110 or 220 VAC, 300 Watts, 50/60 Hz, specify
Requires 100 psi air supply
Requires 250 psi nitrogen supply

4
20

6
15

Series9

Series10

10

9
5
10

Maximum Desaturation Pressure:


200 psi (air/brine system)

0
0.0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

100.0

Brine Saturation, percent pore space

1
0

10

20

30

40

50

60

70

80

90

100

Water Saturation, percent pore space

Determine the capillary pressure desaturation


curve characteristics.

Minimum Desaturation Pressure:


0.1 psi
Sample Size / Capacity:
Max. Height: 6 inches (15.2cm)
Plate Surface Diameter: 12 inches (30.4cm)

Enables determination of Height above free water zone

Wetted Materials:
316 Stainless Steel / Composite / Buna / Ceramic

316 Stainless Steel and graphite composite wetted materials for corrosion free operation

Approximate Footprint Dimensions:


Control Rack: 20 x 30 x 60 inches
Desaturation Chamber(s): Require 18 inch diameter area on
a benchtop for each chamber purchased

Quick release opening for fast and easy sample


insertion and removal.

Specifications subject to change without notification.

CORETEST SYSTEMS, INC.


Up to 5 cells can be run from a single control
cabinet

400 Woodview Ave


Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

ASPE-730
Automated System for
Pore Examination
The ASPE-730 Automated System for Pore Examination performs constant rate mercury injection defining pore structure
at injection pressures to either 100 or 1,000 psia. A number of years ago Yuan and Swanson (1986) introduced an exciting new approach for determining the fine scale structure of reservoir rock pore systems using rate-controlled mercury
porosimetry. The approach was based on a technique that injected mercury into a small core sample at extremely low
rates. During the process, the mercury pressure and volume were accurately measured. Coretest Systems, Inc. has recently developed the Automatic System for Pore Examination, ASPE-730, for determining the three dimensional architecture of pores using rate controlled mercury injection porosimetry. Major improvements in fluid delivery and pressure
measurement technology since the early work allow the ASPE-730 system to further expand the potential of this type of
analysis. Mercury injection under these conditions consist of smooth, reversible changes punctuated by jumps in capillary pressure, the sequence of which follows from the structure of the porous medium and the saturation history The resulting pressure versus volume curve shows a general capillary pressure curve shape with a significant number of measurable, nearly instantaneous, pressure drops. By calculating the volume of the pore segment occupied by mercury in a
given jump, the pore system can be classified into numbers and sizes of both pore bodies and pore throats. The ASPE730 system includes the integral pump coreholder assembly, temperature controlled chamber, vacuum pump, computerdata acquisition system, analysis software, printer and all necessary items required to start performing ASPE measurements. Mercury must be supplied by user.

Features

Specifications

Uses ultra low rate controlled mercury injection

Pump injection rate: 0.00005 to 1 cc/min

Measured data can be used to determine pore size


geometry including pore throat radius and pore
body radius as well a number of other parameters

Pressure Range: 0 - 100 psia or 0 - 1000


psia (other pressure ranges available)

Small compact system designed for maximum precision and ease of use
ASPEDAS analysis software for calculation of
pore throat and body diameters, subison and rison
volumes, capillary pressure curves and residual/
initial saturation curves as well as permeability and
formation factor estimator

Volume resolution: 0.000001 cc


Maximum Sample size: 1" diameter x 1" long
Computer: Windows based, SVGA, CD-R,
Color Inkjet printer
Power: 120 or 240 VAC (specify) 50/60 Hz

Integral chamber seal design for a small system


volume with temperature control

Specifications subject to change without notice.

Utilizes precision pressure transducers with 0.05%


accuracy

CORETEST SYSTEMS, INC.

Mercury injected volume is measured to <0.000001


cc resolution

400 Woodview Ave


Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

BPS-805
Benchtop Permeability System
The BPS-805 is an integrated modular system for performing flow tests on core samples to determine specific, effective, and relative permeability. The system can be configured to use liquids and gases at ambient temperatures. The standard plug size
coreholder can be utilized to 10,000 psig confining pressure and up to 5,000 psig pore
pressure with 1 inch and 1.5 inch diameter samples that are up to 4 inches long. Standard material of construction is 316 stainless steel.
Features
Complete system for performing liquid permeability
tests
Can be supplied with a variety of fluid delivery systems
including a low cost HPLC type or pulsation free Quizix
dual cylinder pumps
Easy to use CHG-106 hassler coreholder with simple
overburden pressure control system
Dual differential pressure transducers with digital displays and bypass valves
Can be supplied with optional piston or bladder accumulators
Computer control data acquisition system available as
an option with easy to use data acquisition software
Corrosion resistant materials used throughout

Specifications
Maximum Sleeve pressure: 9,500 psi
Maximum pore pressure: 5,000 psi
Maximum operating temperature: ambient-40C
(With coreholder mounted on frame)
Core diameter:
1.5" standard, optionally 1.0" and 30mm
Core length: 1" to 4" maximum
Pore fluid wetted materials:
316 stainless steel, Viton, Teflon
Confining Pressure System: pump with gauge, bleed
and isolate valves
Standard Pumping System: HPLC single piston type:
0-10 cc/min maximum 5000 psi
Optional Pumping System: Pulsation free Quizix QX5000 pumping system 0.001 to 50 cc/min
constant rate or pressure modes 5000 psi
maximum pressure.
Options:
Computer Control data acquisition system
Piston or bladder accumulators
DBPR-5 Digital Back Pressure regulator
Available with Hastelloy wetted parts
High temperature oven
Specifications subject to change without notice.

Dome loaded BPR-2 back pressure regulator included

CORETEST SYSTEMS, INC.


Digital Back Pressure regulator available as an option

400 Woodview Ave


Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

CFS-Series
Core Flood Systems
The CFS Core Flood system is a computer controlled advanced system for performing core flood
tests at reservoir conditions using refined or live fluids. All key functions are automated, including
pump and valve control, and data acquisition. The coreholder, valves, accumulators and produced
fluid separator and necessary plumbing are mounted in Coretest Systems unique split oven design
providing easy access to all components during setup. Confining pressure is controlled use the
ACPC-195 Automated Confining Pressure Controller for precision effective pressure control
throughout a test.
All test operation is controlled through sophisticated control software using the WindowsTM platform. The control
software allows for operation both manual and automatic modes where the user has control over valves, pumps, data
logging and other data acquisition. Other features include alarms and calibration windows. A test sequencer allows the
user to predefine unique test sequences which can be saved and run at any time.

Features

Specifications

Automated state of the art system with advanced control and data acquisition software
Unsteady state relative permeability capability
Enhanced oil recovery tests
Formation damage and remediation tests
Quizix Pulsation free pumping system
ACPC-195 for automatic confining pressure control
Precision Quartz pressure transducers with multiple
pressure taps are available as an option
DBPR-5 Digital Back Pressure Regulator
SFS-032 Sonic Produced fluid separator
Inert construction
throughout
Unique split oven
design

Core Size: 1 or 1.5 diameter


Length: 1 to 6 max (other lengths available)
Coreholder Confining: Hydrostatic loading
Maximum operation temperature: 150 C
Maximum Confining Pressure: 9900 psi
Maximum Pore pressure: 9500 psi
Pumping-Flow System: Quizix 5200 or QX-6000Constant
rate or constant pressure, forward
or reverse flow capability air operated valves
Injection rate: depends on pump selected 0-15 or 0-50
resolution 0.001 cc/min
Piston Accumulators: 3 ea with low friction seals
DBPR-5: Digital Back Pressure Regulator
ACPC-195: Automated Confining Pressure Controller
SFS-032 Sonic Fluid Separator: with 100 cc produced volume and <.03 cc resolution
Economical capacitive model also available
Quartz Pressure Transducers: with a resolution of 0.01 psi
3 midstream pressure taps
Fraction Collector with 55 tube capability
Power supply: 110 or 220 VAC 50 or 60 Hz
Options: Biaxial or Hassler coreholders
Gas Injection system
Produced gasometer
pH measurement
Mud or slurry Injection
Specifications subject to change

CORETEST SYSTEMS, INC.

Manual control software screen

23 Las Colinas Lane, #104


San Jose, CA 95119 USA
Phone: (408)229-8185 Fax: (408)229-8188
E-mail: coretest@aol.com
Web page:www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

FDES-Series
Formation Damage
Evaluation Systems
The FDES series of system are used for
performing a variety of core flood and fluid
flow tests including formation damage-remediation stimulation tests on
core samples under elevated reservoir temperature and pressure conditions. The system can be used to test plug size core samples for virtually any flow test including brine sensitivity, acid stimulation, return permeability, critical velocity,liquid permeability and relative permeability.
Mud flow recirculation options are also available.

Features

Specifications

Complete system for performing reservoir condition formation


damage and acidizing- remediation tests

Maximum Confining pressure: 9,500 psi


Maximum pore pressure: 5,000 psi
Maximum Operating temperature: 150 C
Core diameter: 1.5 standard,
optionally 1.0 and 30mm
Core length: 1 to 4 maximum (longer as option)
Pneumatic confining pressure controller
Pulsation free pumping system standard
0.001 to 50 cc/min
constant rate or pressure modes
corrosion resistant construction
Pore fluid wetted materials:
Hastelloy, Viton, Teflon, 316 stainless steel
1 liter piston accumulators: std. Qty. = 3
Dual BPR-2 dome loaded back pressure regulators,
with fraction collector and pH sensor
Options: Multiple pressure taps
Mud or slurry flow options
Pinch type BPR or Digital DBPR-5
Hastelloy B
Hydrostatic or Biaxial loaded coreholder
Multiple pumps for fluid incompatibility testing

Includes pulsation free pumping system with air operated


valves and precision pressure transducers and data acquisition instrumentation
Easy to use hassler coreholder with the capability for forward
and reverse flow with air operated valves
Core mounted on movable tray to facilitate core replacement
Includes three fluid transfer vessels for use with corrosive
fluids
Easy to use software with semi-automatic test sequence
operation, as well as manual control of pumps and valves
Corrosion resistant materials used throughout
Fraction collector and pH measurement Included or optional
digital balance

Specifications subject to change without notice.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

AP-608
Automated Klinkenberg
Permeameter / Porosimeter
The AP-608 Automated "Klinkenberg" Permeameter-Porosimeter is a cost effective advanced system for performing automated permeability and porosity tests at overburden pressures to 9950 psi over a wide permeability range. The AP-608 uses a pressure decay technique to determine Klinkenberg corrected permeabilities, slip and turbulence correction factors. Porosity is determined using a Boyles law technique. The unique
design of the AP-608 hydrostatic coreholder not only enables quick sample loading and unloading, but also
offers quick diameter changes in less than 5 minutes for the production oriented laboratories. It is now standard with a hydrostatic loading feature. Simply load the core in the core-holder, enter the test and core data
into the included control computer, and the AP-608 automated control system does the rest. Microsoft Windows compatible software, and other advanced features make the AP-608 the best core analysis system in
the world.
Note: Coretest Systems makes no warranties or representations when measuring very low permeabilities (<.1 md) using
helium. It is possible that the API standard pulse decay calculation method used in the AP-608 system may determine a
higher equivalent liquid permeability than is measured using a steady state flow system. For low to very low permeabilities we recommend using Nitrogen to obtain a more accurate measurement of Kl until this calculation issue is resolved.

Features

Specifications

Permeability (Klinkenberg Corrected)

Permeability Range: 0.001 mD to >10 Darcies

Permeability (air equivalent permeability @ specified


mean pressure)

Porosity Range: 0.01 to >40 percent


Core sample Size:
Length: 0.75 to 4.0 inch
Diameter: standard 1.0 inch or 1.5 inch
Optional: 30 mm diameter

Slip factor "b"


Inertial Coefficients (Beta and Alpha)
Pore volume of core sample
Porosity (if bulk volume is known)

Hydrostatic loading assembly


shown at left.
Computer Screens

Overburden Pressure: 300 to 9,950 psi


Gas System Requirements:
Dry helium at greater than 250 psi input pressure
Dry air pressure between 90 and 125 psi
Electrical Requirements:
110/120 VAC, 15 amps, 60 Hz
or 220/240 VAC, 10 amps, 50 Hz
Options Available:
Digital calipers interfaced into control computer
Grain volume chambers
Digital balance interfaced in computer
Specifications subject to change without notice.

Optional Grain
Volume
measuring
assembly
shown to right.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

MIS-Series
Mercury Injection Systems
The MIS Series of mercury injection systems are designed for injection pressures to 15,000 psi which enable pore entry
radius measurements to below 0.01 microns. The systems include software that calculates pore entry radius, converts
pressure data to equivalent air/brine, air/oil, and oil/brine systems, and displays the data in tabular and graphical formats
that can be used to correlate the mercury injected data to reservoir capillary pressure characteristics. The measured
data is presented in cumulative and incremental tabular from with graphical representations of mercury saturation versus
pressure, equivalent system saturation versus pressure, and pore size distribution versus percent pore space in cumulative and incremental (Histogram) formats. A J-Function calculation for correlation of capillary pressure data across several systems is also available.
A sample is placed into the measuring chamber and a vacuum is imposed upon the system. The mercury level is then
brought up until the sample is covered. The chamber pressure is raised in an incremental fashion, injecting mercury into
the sample. This volumetric data is corrected for system variations to obtain injected volumes. Data is measured from
vacuum through the threshold pressure of the sample and on to 15,000 psi. Retraction curve can also be performed with
the MIS. Another feature of the MIS-Series is the easy opening chamber cap that offers repeatable, user friendly sample
loading and unloading. The coreholders are located in a temperature controlled ventilated chamber for minimizing operator exposure to mercury vapors.

Features
Measured data can be used to calculate pore size distribution and capillary pressure characteristics.
Injection pressures to 15,000 psi define pore entry radius
to below 0.01 microns.
System includes spreadsheet software for calculation of
pore size distribution and conversion of pressures to air/
water, air/oil, and oil/water systems.
Software includes tabular and graphical printout capabilities for injected volume, pressure, pore entry radius, and
system pressure conversions.
Integral chamber seal design for a small system volume.

Specifications
Power / Utilities:
110 or 220 VAC, 700 Watts, 50/60 Hz, specify
Requires 100 psi air supply
Maximum Injection Pressure: 15000 psi
Minimum Pore Entry Radius: 0.01 micron
Sample Size / Capacity:
Max. Height: 2 inches (5.08 cm)
Max. Diameter: 1.5 inches (3.81 cm)
Wetted Materials: 316 Stainless Steel / Teflon / Viton
Approximate Footprint Dimensions:
Computer Controller: 24 x 24 x 36 inches
System: 40 x 36 x 60 inches

Available in a one or three sample version


Utilizes precision pressure transducers with 0.01% accuracy.

Specifications subject to change without notice.

Mercury injected volume is measured to 0.01 cc resolution


Computerized data acquisition and control capabilities that
minimize operator error.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CAPILLARY PRESSURE
VS.
WETTING PHASE SATURATION

CORETEST SYSTEMS, INC.

Permeability, millidarcies:
Porosity, fraction:

(MERCURY INJECTION DATA)

1.20md
0.110

Core ID:

tight sandstone

W ell ID:

Tight One

Date Tested:

8/2/98

16000

15000

14000

13000

12000

11000

Capillary Pressure, psia

10000

9000

This graph shows data collected with the


MIS-621 on a tight sandstone sample. The
System can perform drainage and imbibition
tests. Once the tests are complete the data
can be analyzed using a Microsoft excel
macro that automatically corrects for cell
conformance, calculates pore size distribution and other key parameters. Data is the
formatted for easy printout in graphical or
tabular files.

8000

7000

6000

5000

4000

3000

2000

1000

0
0

10

20

30

40

50

60

70

80

90

100

W etting Phase Saturation, percent pore space

This figure shows the main software


control panel for MIS-621. The user is
updated through the status box in the
lower part of the screen on every operation the system performing during
a test . A graphical display shows the
mercury injection pressure Vs core
saturation for each sample. User
prompts make sample loading and
test operation simple and repeatable.

This photo shows the insider of


the MIS-621. All components are
easily accessable for rapid maintenence and repair. Ventelation
and drip trays help prevent user
exposure to mercury and make
clean up a snap.

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

RCS-760
Reservoir Condition
Capillary Pressure System
The RCS-760 is a computer controlled advanced system for performing capillary pressure and optionally electrical property measurements at reservoir conditions using refined or live fluids. All key functions are automated, including pump and valve control, and data
acquisition. Special oil and water-wet semi-permeable membranes allow for both forced drainage and imbibition processes. High temperature pump cylinders are used to accurately control pore and differential pressures. The differential pressure pump is mounted in
the oven to eliminate temperature corrections. Formation factor, cementation exponent, resistivity index, saturation exponent, and
brine resistivity can be measured with the resistivity measurement/flow options. Included with this option is the DRM-98 Digital Resistance Meter. The system can measure 2 and 4 terminal resistances. All brine wetted parts are manufactured from Hastelloy, ceramic, PEEK and Silver. All components in the oil filled sections are manufactured from stainless steel. The fluid pumps, coreholder,
valve, reservoirs and necessary plumbing are mounted in Coretest Systems unique split oven design providing easy access to all
components during setup. Standard confining pressure is controlled using a manually set pneumatic system (a computer-controlled
system is available as an option). All test operation is controlled through sophisticated control software using the Windows platform.
The control software allows for operation both manual and automatic modes where the user has control over valves, pumps, data logging and other data acquisition. Other features include alarms and calibration windows.

Features

Specifications

Offers accurate determination of capillary pressure


curves at reservoir conditions

Core Size:
1.5" diameter (optional 1.0", 30mm)
Length:
1" to 4" maximum
Maximum operation temperature:
150 C
Maximum Confining Pressure:
9500 psi
Maximum Pore pressure:
6000 psi
Maximum differential pressure:
+200/-40
Injection rate:
0.1cc/day to 2 cc/min
Maximum displaced volume:
20 cc
Approximate dimensions:
48" x 60" x 72"
Power supply:
110 or 220 VAC 50 or 60 Hz
Options:
Second coreholder option
Computer-controlled confining pressure system
Inserts for 1.0 and 30 mm diameter samples

The system can operate in both incremental and continuous injection modes
Both brine and core resistance including determination
of "m", "n", resistivity index and formation factor
Oil and water wet membranes standard for forced and
spontaneous drainage and imbibition procedures
High temperature pumps for precise volume measurement and pressure control
Inert construction throughout
Unique split oven design
Automatic operation and data collection software
Display-Calculation software included

Specifications subject to change without notice.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

PRCS-763
Production Capillary
Pressure System
The PRCS-763 is a computer-controlled, research grade system for performing capillary pressure and optionally electrical property
measurements at reservoir conditions on up to 3 samples simultaneously. All key functions are automated, including inlet and differential pressure, valve control, and data acquisition. Special oil and water-wet semi-permeable membranes allow for both forced drainage
and imbibition processes. Individual high temperature produced fluid
cells are used to accurately monitor core saturation.
Formation factor, cementation exponent, resistivity index, saturation
exponent, and brine resistivity can be measured with the PRCS-763
system. Included with this option is the DRM-98 Digital Resistance
Meter. The system can measure individual 2 and 4 terminal resistance
and brine resistivity. All brine wetted parts are manufactured from
Hastelloy, ceramic, PEEK, Teflon and Silver. All components in
the oil filled sections are manufactured from stainless steel.
The hydrostatic coreholders, valves, produced fluid cells, fluid reservoirs and necessary plumbing are mounted in Coretest Systems
unique split oven design providing easy access to all components
during setup. Confining pressure is controlled using the PCI-112 Automated Confining Pressure Controller for precise "effective pressure" control throughout a test.
All test operation is controlled through sophisticated control software using the Windows platform. The control software allows for
operation both manual and automatic modes where the user has control over valves, pressure controllers, data logging and other data
acquisition. Other features include alarms and calibration windows.

Features
Offers accurate determination of capillary pressure
curves and electrical measurements at reservoir conditions

Specifications
Core Size: 1.5" diameter (optionally 1.0" and 30mm
Length: 1" to 4" maximum

The system can measure up to 3 cores simultaneously

Number of Coreholders: 3

Oil and water wet membranes standard for spontaneous and forced procedures

Maximum operation temperature: 150 C

High temperature fluid measurement cells for precise


saturation measurement Inert construction throughout

Maximum Pore pressure: 5000 psi

Maximum Confining Pressure: 9500 psi

Unique split oven design

Maximum differential pressure: 200 psi (two transducers for each coreholder)

Automatic operation and data collection software

Maximum displaced volume: 20 cc


Volume resolution: <0.01 cc
Approximate dimensions: 55" x 60" x 72"
Power supply: 110 or 220 VAC 50 or 60 Hz
Specifications subject to change without notification.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
One coreholder shown

Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

RPS-Series
Relative Permeability
Systems
The RPS-Series systems offer a modular design that
enables several configurations for performing relative
permeability tests without having to buy several complete systems. The standard Coretest Systems, Inc.
roll-on oven design offers the most user friendly
system on the market for maximum efficiency during
test setup and cleanup procedures. The use of uncontaminated reservoir fluids and elevated temperature/pressure
insures accurate results for reservoir performance calculations. Advanced control software controls all aspects of the
system, either in manual mode where the syringe pumps can be positioned, valves opened or closed or in fully
automatic mode where all aspects of a standard test are computer controlled through a test sequencer. Optional
extended length hydrostatic type core holder for use with composite cores up to three feet in length. Manually operated
fill/isolate valves allow for easy filling of the system with fluids, even under pressure conditions. The steady-state system
offers Quizix five cylinder recirculating pumping systems enabling closed system, low volume, continous pulsation free
flow with unmatched precision. Optional capillary pressure and electrical property measurement configuration is also
available as well as Gas/Liquid Relative Permeability capability. Single and dual energy X-ray scanners and transparent
coreholder are also available as options.

Features
Modular design enables several test configurations from
same base system, offering future expansion/upgrade
possibilities without having to purchase another
complete system.
Can be configured for Liquid/Liquid or Gas/Liquid
relative permeability measurements as an Unsteadystate or Steady-state procedure.
Complete computerized control and data acquisition or
manual control options.
Available in high-end research grade configurations,
production oriented configurations, or economical
models.
X-ray scanners are available as option for in-situ saturation monitoring.
Relative Permeability Data analysis software (basic and
advanced) are also available along with training

Specifications
Max. Pore Pressure: depends on pumps and transducers
standard 5000 psi option to 9500 psi
Max. Confining Pressure: 9950 psi
Max. Temperature:
150 oC
Flow Rate Range:
recirculating Continuous: 0.001 - 15 cc/min(SP-5200)
once though type (QX-6000) 0.001 to 50 cc/min
Pump Modes: (with std. Quizix pumps)
Constant Rate
Constant Pressure
Constant Differential Pressure
Available Relative Permeability Capabilities:
Unsteady State:
Liquid/Liquid (standard)
Gas/Liquid (optional)
Steady State:
Liquid/Liquid (optional)
Gas/Liquid (optional)
Saturation Determination Methods Available:
Volumetric via Acoustic Separator (standard)
Volumetric via Capacitive Separator (optional)
In-situ via X-ray attenuation (optional)
Data Calculation / Report Generation software available

Specifications subject to change without notice.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

URC-628
Ultra Rock Core Centrifuge
The URC-628 Ultra-Rock Centrifuge is a state of the art rock core centrifuge. The URC-628
can be used to perform dynamic capillary pressure measurements as well as sample preparation by displacing to connate water or residual oil saturations. The URC-628 allows for rapid
determination of capillary pressure (drainage and imbibition depending on the rotor and sample cup holder used) characteristics on core samples at very high rotational speeds and
equivalent displacement pressures of up to approximately 1250 psi (dependant on fluids
used). The URC-628 can also be utilized for rapid sample preparation to restored state conditions for subsequent testing in various
test equipment. Rotor and sample chambers offer the ability to spin 1.0" diameter core plug samples at rotational speeds up to 20,000
RPM and 1.5" diameter core plug samples up to 16500 RPM. The URC-628 comes standard with
a 50 or 60 Hz (specify when ordering) 220 VAC system including a view port window and digital
strobe system as well as an integrated vacuum pump. The rotors, core sample chambers for
drainage and imbibition studies, collection tubes and other accessories are quoted separately.
A digital speed control with the ability to program multiple speeds at specified intervals and a precision temperature control system (0-40C) is included. Programmable ramps and holds, rotor
imbalance shutoff and a host of other advanced features are standard on the URC-628 control
panel. The URC-628 is equipped with a digital strobe that allows the user to monitor fluid levels in
each of the cells sequentially.
The URC-628 can also be supplied with an automated measurement option that allows the user to
perform automatic data collection (measurement volume at selected speeds for each cell) and
processing using windows based PC and special hardware and data acquisition software. This
also allows the system to be used for performing relative permeability measurements. The automated data collection option is also available for older L8-60MP centrifuges. Consult Coretest for
more information.

Features
Extended rotational speed for greater equivalent displacement pressure of approximately 1250 psi
(dependant on fluids used)

Optional computerized data acquisition system for


automatic collection of test data and control of centrifuge system

System can be used for drainage and imbibition


modes using the proper rotor sample chamber comRapid determination of capillary pressure characteristics bination for both air/liquid and oil/brine
on plug size core samples
Uses traditional PIR type rotors (16.5 and 20) and
Enables rapid sample preparation to restored state con- sample chamber combinations (displacement by
water and displacement by oil/air)
ditions to meet demanding production schedules
Viewing window and digital stroboscope offer simple
sample selection and accurate volumetric determinations
Programmable rates, spin duration, & temperature controls to 40 C
Imbibition and drainage rotors and sample chambers for
1" and 30mm and 1.5" diameter samples

Extended warranties and service contracts are


available as an option

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

URC-628 Ultra Rock Centrifuge


Specifications
Basic centrifuge:
Speed control 20 rpm of set speed
Sample imbalance tolerance Up to 10% of volume in opposite tubes
Drive cooling Air-cooled
Refrigeration system Thermoelectric
Set temperature range 0 to 40 C in 1 increments
Temperature control 0.5 C of set
Ambient operating range 15 to 40 C
User-settable programs 9 user programs, with delayed start capability
Acceleration/Deceleration rates 10 Accel/11 Decel
Moisture-purging vacuum system
Heat output 1.0 kW/h (3,400 BTU/h)
Sound level 3 ft (0.9 m) away 57 dBa
Dimensions H x W x D in 47.5 x 37 x 26.5
(mm) (1,207 x 940 x 673)
Weight 1,025 lb (465 kg)
220 VAC 50 or 60 hz specify when ordering
Rock Core Special Features:
View port door (locking)
Integrated Strobe and control system
Vacuum capability to below 10 microns
Special heat sink integrated into system
Sample chamber and rotor specifications
PIR-16.5 regular and inverted rotors and sample chambers
for 30 mm and 1.5" diameter samples up to 2" long
PIR-20 regular and inverted rotors and sample chambers for 1" diameter samples
Extra sample chambers
Fluid collection tubes from 6 to 23 cc for PIR-16.5 rotors and 1-4 cc for PIR-20 rotors
Holding racks and spare parts (seals etc) also available
Optional Automated data acquisition for URC-628 Ultra Rock Centrifuge.
Includes computer interfaced digital camera with strobe, computer and control software. The system can
make measurements at user specified intervals. Data presentation software for displaying capillary pressure curves is also included. Advanced data analysis software for determining relative permeability curves
is available as an option. Contact Coretest Systems for more details. Resolution is better than <0.05 mm.
Automated data acquisition specifications:
Windows based computer
Minimum 20 GB hard drive
17" monitor
Windows compatible Color ink jet printer
High resolution high speed digital camera with lens mounting and interface cable
Strobe interface to URC-628
Data collection software
Excel spreadsheet for presentation of collected data

Specifications subject to change without notice.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

www.coretest.com

A New Generation of Ultra High Speed Rock Core Centrifuges


The URC-628 is the newest generation of ultra high speed rock core centrifuges available to the
core analysis laboratory for rapid determination of capillary pressure curves and for sample
preparation. With the addition of an optional automation and data analysis package, the URC-628
can also be used to determine relative permeability curves for the displaced phases in both the
drainage and imbibition modes. The advanced automation package also speeds up the test
procedure with automated equilibrium determination and subsequent automatic progression to the
next step.

The URC-628 has a number of features not


available in previous high speed rock core
centrifuges, and is compatible with existing Rock
Core Centrifuge rotors, buckets and sample
accessories. For example, a standard or inverted
PIR 16.5 and PIR 20 rotor can be used in the
URC-628.

Coretest

Systems,

Inc.

is

manufacturer and supplier of these rotors and


accessories.

A Complete Solution for Laboratory Analysis


The URC-628 is a critical tool for the modern special core analysis laboratory. It provides the user
with an ideal technology to prepare samples for other tests and determine capillary pressure
curves. Features found on the URC-628 make operation simpler than ever before possible. The
addition of an optional data acquisition and analysis package provide a powerful system for
advanced testing and analysis. New overburden rotors and sample chambers allow for testing
under realistic reservoir stress conditions.

Rotor design, manufacture and safety considerations


Coretest Systems, Inc. is a Beckman-Coulter, Inc. Channel Partner. We design and manufacture
these rotors to strict tolerances and test them at high speed. Weight in each sample chamber is strictly
controlled during the machining process.
Standard and Inverted rotor/sample chamber assemblies and supplies for performing capillary
displacements as well as relative permeability tests, are available directly from Coretest Systems, Inc.
When ordering a rotor, it can be fit with both standard and inverted sample chambers. If a set of sample
chambers is ordered at a later date the rotor must be returned to Coretest to have it fitted to the rotor
being used or a new rotor should be ordered.
Typically 3 or 6 cells are used in each rotor and the rotor can accommodate both standard and
inverted type sample chambers.
The lifetime of a rotor assembly is determined by the amount of time it is used at defined speeds and
temperatures. Rotors and sample chambers will not last indefinitely and should be replaced when their
usable service life is up.

Rotor and Sample Chamber Assemblies


The URC-628 is the latest generation of centrifuge available AND is compatible with previous rock core
ultracentrifuge rotors, buckets, and sample accessories. Both the PIR-16.5 and PIR-20 can be used
in the URC-628.
Maximum rotational speeds are dictated by the rotor and the temperature of the test. An overspeed
disk attached to the rotors insures safe operation by limiting the maximum rotational speed.
Rotational speeds to 20,000 RPM are possible with the 1.0 6 place rotors.
New rotor and sample chambers include:
The PIRS-120 rotor for displacements by air/oil for six core 1.0 inch diameter by up to 1.0 inches in length.
The PIRI-121 rotor for displacements by water for six cores 1.0 inch diameter by up to 1.0 inches in length.
The PIRS-122 rotor for displacements by air/oil for three cores 1.5 inch diameter by up to 2.0 inches in
length.
The PIRI-123 rotor for displacements by water for three cores 1.5 inch diameter by up to 2.0 inches in length.
The New PIRO-124,125 Overburden pressure rotor/sample chamber is now available. This new rotor
design will enable the application of a constant confining pressure during rotation.

www.coretest.com

Basic History and Theory


of the Centrifuge in Core Analysis

Exploded view of a PIRS-120 standard sample


chamber.

The centrifugation of rock core samples for the purposes of


liquid saturation preparation and the study of capillary
pressure desaturation curves has been in use since the mid
1940's. The basic use of capillary pressure data is to aid the
petroleum engineer in determining the height of the oil-water
contact in a reservoir. A stable oil-water transition zone
develops in a reservoir over geologic time primarily as a result
of pore geometry, the different liquid densities, interfacial
tensions that exist between the liquids and rock material, and
the force of gravity. The force of gravity is very small and
therefore is the primary reason this transition zone forms very
slowly over geologic time. The use of a centrifuge basically
produces the same type of force on the liquids as does gravity
in nature, but since the force is several thousand times greater
than gravity, the time it takes to move the liquids in the core is
dramatically reduced. In comparison to the popular (yet very
slow) porous plate desaturation technique, the URC-628 is
much faster, and also extends the definition of the standard
gas/water capillary pressure curve from about 200 psi
(maximum for most porous plate) to almost 1300 psi across a
core sample.
As technology has developed, so has the accuracy and
versatility of the centrifuge. The URC-628 is today's state-ofthe-art centrifuge, offering better accuracy, programmability,
and optional computerized data acquisition for automated
relative permeability, as well as capillary pressure procedures.
The standard URC-628 also allows for elevated temperature
operation to 110 C.

NEW! Confining Pressure Rotor


and sample chambers
This is a unique system for running rock core centrifuge tests on core samples under realistic overburden
pressures. This new design (patent applied for) recreates a stress environment using a reusable unique cell
holder that is easy to use and reliable. These cells are perfect for use with samples that exhibit strong pore
size stress dependence or unconsolidated samples. The 1.5" cells are capable of operating at overburden
pressures to 4000 psi. The overburden rotors are available with interchangable sample cups for running air/oil
and water displacement tests. The 1.0" confining pressure inserts can operate at overburden pressure in
excess of 5000 psi. The 1" sample chambers can be used in existing PIR-16.5 or Coretest new PIR-122/123
rotors sample cups. The confining system requires a special sample loading apparatus in order to apply the
overburden pressure and must be purchased with the cells. Pore fluids contact only Viton, PEEK,
Polyethersulfone, and Titanium.

Automated Data Acquisition and Control System (optional)


Coretest Systems, Inc. has integrated into the URC-628 a state-of-the-art data acquisition and control
package which includes:
Automation of the centrifuge process using a PC-based
computer acquisition system
A continuous light source enabling the collection of as
many as 19,000 images per second
A CCD line scan camera allows measurement of the
production data at least 25 times more sensitive than
manual measurements
Laser sensors to determine the speed of the rotor to
within 1 rpm and updates the speed on every
revolution
Controls speeds from 100 to 20,000 rpm
Enables automated incremental centrifuge rotation
speed changes up to 16 times per experiment for up to
one week per speed

Collects and stores image data for all buckets on a single rotation
Two and Three phase data acquired
Stores time, temperature, and rpm with each image file
Corrects image collection at each rpm for electronic time delay
Automatically resumes data collection and restarts centrifuge after power interruption
Provides adjustment of imaging system while collecting data
Analyzes collected images into tabular ASCII data files of fluid production vs. time and speed
Convenient help menu to assist in experimental setup

Centrifuge Data Analysis Package From


Westport Technology Center Intl. sold
exclusively through Coretest Systems, Inc.
This is an advanced centrifuge data analysis software
package that works in conjunction with the optional data
acquisition and control system.
Converts the measured production data into capillary
pressure and relative permeability curves
Prior to a centrifuge test the operator can perform
experiment simulations to best select the speeds and
collection modes
A comprehensive data reduction program fits the
production data to various models to achieve the best fit of production to produce capillary pressure or
relative permeability curves for the sample
The data reduction program also has the capability to do bi-modal modeling for isolation of matrix
permeability or volume from fractures to provide better estimates of permeability and porosity ratios
Leverett J function dimensionless values are provided for comparison with mercury capillary pressure
curves and for better comparison between reservoir cores of varying absolute permeability
The system can be used to provide wettability values from Amott, USBM, and Oil saturation vs. Bond
Number (Abrams) relationships, with values that are orders of magnitude better than with flow techniques

www.coretest.com

Basic URC-628 Centrifuge Features


Speed control +/- 20 rpm of set speed
Drive cooling Air-cooled
Vacuum capability to below 10 microns (2 stage mechanical
pump and diffusion pump)
User-settable programs 9 user programs, with delayed start
capability
Acceleration/Deceleration rates 10 Accel/11 Decel
Moisture-purging vacuum system
Sound level 3 feet (0.9 meters) away 57 dBa
Dimensions HxWxD inches: 47.5 x 37 x 36
Weight: 1,150 lbs.

Standard Rotors available


PIRS-120 - Displacement by air/oil, 6 ea. 1.0" (or 30 mm)
diameter by up to 1.0" long core, max. 20,000 rpm
(identical to PIR-20)
PIRI-121 - Displacement by water, 6 ea. 1.0" (or 30 mm)
diameter by up to 1.0" long core, max. 20,000 rpm
PIRS-122 - Displacement by air/oil, 3 ea. 1.5" diameter by
up to 2.0" long core, max. 20,000 rpm (identical to
PIR-16.5)
PIRI-123 - Displacement by water, 3 ea. 1.5" diameter by
up to 2.0" long core, max. 20,000 rpm
PIRO-124 - Overburden rotor and sample chambers for
air/oil and water
PIRO-125 - Overburden inserts for 1.0" diameter samples
that fit into existing PIR 16.5 rotors

Rotor Chamber Temperature


Temperature control +/- 0.5 C
Ambient operating range 15 C to 30 C
Infrared temperature sensor with digital readout
with 0.1 C resolution
Digital Temperature controller
Rotor chamber temperature range from ambient
to 110 C
Over temperature protection

Strobe

Fiber optic Xenon strobe with backlight


Auto/manual operation modes
Microprocessor controlled strobe delay
Delay set cw/ccw set
Sample selector switch (positions from 1 to 6)
Automatic/manual intensity control
Range up to 400 flashes per second

Volumetric Receiving Tubes


For PIRS-122 & PIRI-123 rotors/buckets:
(polyethersulfone, polyphenylsulfone) 6 ml,
12 ml, 23 ml
For PIRS-120 & PIRI-121 rotors/buckets:
polyethersulfone, 1 ml, 2 ml, 3 ml, 4 ml
For PIRO 6,12, and 23 ml tubes available,
other sizes available as options

Additional accessories
O-rings, rubber cushions, over speed disks,
lubricants, rotor and cell holders, support cones,
strobes and windows, tools and accessories,
overburden loading system
Data acquisition System
PC-based system with computer, monitor,
printer, high resolution line scan camera,
camera mounting brackets, data image capture
board, dual continuous lighting system and
laser sensors with all connecting cables and
accessories
Analysis software
Available as an option (capillary pressure and
relative permeability)

CORETEST SYSTEMS, INC.


23 Las Colinas Lane, #104
San Jose, CA 95119 USA
Phone: 408-229-8185 Fax: 408-229-8188
Email: coretest@aol.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

RPXS-SERIES X-Ray Relative Permeability

Software main control screen showing flow schematic with


automated valves, DBPR control, Quizix pump control,
confining control, separator control, etc.

Pull-down screen showing options to set up


the automated sequencer. This allows the
operator to customize the automated procedure that is desired.

Specifications
Core Size: 1.5 diameter (optionally 1.0,30mm)
Length: 2 to 12 maximum (12 core size)
12-24 with 24 core size option
24-36 with 3 ft core size option
Maximum operating temperature: 150 C
Maximum Confining Pressure: 9950 psi
Maximum Pore pressure: 7500 psi
Maximum displaced volume: >100 cc
Separator Volume resolution: <0.05 cc
Pump specifications: once through or
recirculation with flow rate from 0.001
to 15 cc/min.
X-ray source: 2-Phase=80Kv, 250 microamps
3-Phase = 140Kv, 2 milliamps

Scanner: scan rates <0.01 to 30cm/min


Scan Resolution: <0.005
Differential pressure: measured using either
quartz transducers or differential pressure transducers from 0.1 to >500 psid
Options: Three phase capabilities
2D saturation scans
Specifications subject to change without notice.

The above screen shows how the operator can customize the way data is saved to file. Data can be
saved in any order and can be saved either in text or
Excel format.

CORETEST SYSTEMS, INC.


23 Las Colinas Lane, #104
San Jose, CA 95119 USA
Phone: (408)229-8185 Fax: (408)229-8188
E-mail: coretest@aol.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

PBC-925
Pore and Bulk Volume
Compressibility Systems
The PBC-925 system offers a digital system for measuring the effects of pore pressure depletion on
pore and bulk volume in a "wet" reservoir. The "wet" measurement technique is considered to be the
most representative of a hydrocarbon reservoir. Hydrostatic or Biaxial ("Triaxial") loading is available
along with optional axial strain measurements simultaneously. Systems can be configured to perform measurements by the Effective Stress or Simulated Reservoir Stress procedures. All test procedures are run from the control software for precise repeatable tests.

Features
Easy to use biaxial coreholder with the capability for axial and radial strain measurements (optional)
Core mounted in heat shrink tubing to minimize conformance corrections
Pore fluid components are mounted inside
oven to minimize volume corrections and
temperature drift
Easy to use software with complete calibration sequence and automatic test sequence
operation, as well as manual control of
pumps and valves
Corrosion resistant materials used throughout

Specifications
Maximum Axial and Sleeve pressure: 10,000 psi
Maximum pore pressure: 9,750 psi
Maximum Operating temperature: 150 C
Core diameter: 1.5" standard, and 30mm
Core length: 1" to 4" maximum
Axial and Sleeve pressure pumps
Stroke volume 100 cc
Resolution <0.01 cc
Pore pressure pump mounted inside oven
Pore pump
stroke volume 10 cc resolution 0.001 cc
Pore fluid wetted materials:
Hastelloy, Viton, Teflon
Computer System:
Windows based CPU
SVGA graphics
CD-ROM
Color inkjet printer
Control software
Includes Microsoft Excel
Options:
Axial and radial strain measurement
Permeability measurement
Optional 1 diameter system
Optional multiple core holders
Specifications subject to change without notice

Uses Coretest Systems unique Split oven


for easy access to all components

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

RPAS

PRODUCT OVERVIEW

Relative Permeability Analysis Software


DATA IMPORT FEATURES:The data import
window allows the user to import data into the
systems and then delete and/or edit the data
as required. Locations and headings for data
columns can be selected and the data corrected for offsets. The user can also determined breakthrough and trim data sets when
necessary. Edited data can be saved in ASCII
tab delimited files with new file names. The
graph window is configurable, and will allow
the user to display a variety of parameters.
Tabular data is also displayed in the window
for editing and selecting.

FORMULA EDITOR AND CURVE FIT CAPABILITIES: Once data is introduced from
the import screen, the data can be fitted and
filtered using fixed polynomial or other curve
fit relationships or fitting to non-linear relationships using the powerful Lev-Mar curve fitting
system that will allow the user to fit to a custom user defined equation. Once entered, the
system will fit and if selected, will run a automatic optimization routine that can provide a
simpler less hands on approach to generating
a relative permeability curve

FINAL REPORT FEATURES: At the completion the curve fitting, the user can display relative permeability vs. saturation curves, as well
as a number of different plots on the configurable display window.
Tabular final results can be imported into Excel for creating a printed version. (ExcelTM not
included)

Requirements:
Pentium with minimum of 128 MB ram
1 mb of disk space for program
Runs under Windows TM NT, 2000, XP
Demo version available
e-mail to Coretest@aol.com

CORETEST SYSTEMS, INC.


23 Las Colinas Blvd. #104
San Jose, CA 95119 USA
Phone: (408)229-8185 Fax: (408)229-8188
E-mail: coretest@aol.com

CORETEST SYSTEMS, INC.


Setting a new standard in core analysis equipment

PRODUCT OVERVIEW

FSDS-649
Mud Flow and Formation Damage
Stimulation System
The FSDS-649 is used for
performing fluid flow and mud
flow tests as well as remediation and cleanup studies on
core samples under elevated reservoir temperature and
pressure conditions. The system includes a Mud Loop for
performing recirculating mud and treatment fluid flow tests.
The special coreholder is equipped with two replaceable
heads which allow for flow parallel to the core face, or at a
45o angle into the face.
Features

Specifications

Complete system for performing reservoir condition fluid flow,


remediation and cleanup studies.

Maximum Confining pressure: 6,000 psi


Maximum pore pressure: 3,500 psi
Maximum Operating temperature: 150 oC
Core diameter: 1.5 standard,
Core length: 1 to 4 maximum
Confining pressure control: automatic
Pulsation free pumping system standard
0.001 to 50 cc/min
Mud flow rate: 0.03 to 11 gal/min
Mud reservoirs: 2-liter, 3 ea.
Pore fluid wetted materials:
Hastelloy, Viton, Teflon, 316 stainless steel
2-liter piston accumulators: std. qty. = 1, opt. 2 or 3
Back pressure control: digital DBPR-5 regulator
Produced fluid measurement: digital balance
Pressure measurement: 4 ea. quartz transducers
Options: - high flow dual-cylinder pumps (400 cc/min)
- gas flow system
- Differential pressure tap transducers

High accuracy quartz pressure transducers for monitoring


differential pressure at upstream and downstream position on
the core as well as at 2 midstream points
Mud loop recirculation system for performing recirculating
mud and treatment fluid flow tests
Multifunction coreholder equipped with two replaceable
heads for parallel and 45o flow.
Recirculating pump magnetic drive type with HP motor
drive and 316 Stainless Steel parts
Easy to use software with semi-automatic test sequence
operation, as well as manual control of pumps and valves
Corrosion resistant materials used throughout

Specifications subject to change without notice.

CORETEST SYSTEMS, INC.


400 Woodview Ave
Morgan Hill, CA 95037 USA
Phone: (408) 778-3771 Fax: (408) 779-9418

E-mail: coretest@aol.com
Web page: www.coretest.com