To install the software use the setup.exe application and the process will begin. When the license
server window appears, enter chem-ds5 as the server Address and Port 7200, as below. NOTE: The
port number must be as below and is different from that used for ACD 11 (7199)!
When this is complete you should copy the DMILLIB.DLL patch from the ACD 12 folder and place this in
the C:\Program Files\ACD12 folder on your local PC (replacing the existing copy) [This patch is
necessary for the on-line prediction tools (I-Lab) to operate correctly].
The on-line prediction tools (accessed within ChemSketch drawing program that is installed as part of
the ACD suite) requires the following options to be configured for access to the server (if you have an
older ACD installation this information may already be shown correctly):
Under I-Lab -> Options enter the server URL address as below:
Tick the Server authentication box and enter the User ID and Password that gives you access to the
Chemical Data Service at Daresbury. Individual user IDs and passwords can be obtained by completing
the simple registration form at:
http://cds.dl.ac.uk/oxform
This requires you to have a valid Oxford University email address.
b) Laptop
A free to use (academic) version of the 1D and 2D NMR processing software can be installed from the
ACD website, and is now recommended for use on laptops away from the department:
http://acdlabs.com/resources/freeware/nmr_proc/index.php
This requires you to register on-line with ACD before use.
This may be installed in parallel with the networked version if desired, in which case a separate folder
name (eg ACD12-Laptop) must be defined for this installation. The free academic version is for
processing only and will do give access to any of the data basing facilities described below.
When installation is complete you should copy the DMILLIB.DLL patch from the Chem-ds5 ACD_12
folder and place this in the C:\Program Files\ACD12-Laptop folder (or as defined for the installation)
on your local PC (replacing the existing copy). [This patch is necessary for the on-line prediction tools
(I-Lab) to operate correctly]
The on-line prediction tools (accessed within ChemSketch drawing program that is installed as part of
the ACD suite) requires the following options to be configured for access to the server (if you have an
older ACD installation this information may already be shown correctly):
Under I-Lab -> Options enter the server URL address as in the figure above.
Tick the Server authentication box and enter the User ID and Password that gives you access to the
Chemical Data Service at Daresbury. Individual user IDs and passwords can be obtained by completing
the simple registration form at:
http://cds.dl.ac.uk/oxform
This requires you to have a valid Oxford University email address.
You can select NMR, Naming or Phys-Chem options. In NMR you can predict 1H, 13C, 31P, 19F or 15N
spectral predictions as well as investigating whether your or similar compound(s) are represented in
ACDs databases
Prediction allows you to see a computed spectrum, based on proven assignments from the same or
similar compounds taken from over 150,000 compounds in the literature. 13C is particularly powerful
and tends to be most reliable and accurate.
The phys-chem options also allow you pKa, solubility, logP etc predictions
Go to File => Import an 1r/ 2rr spectrum (or fid/ser file) from the selected NMR data folder
(make sure that file of type has (AutoDetect) flagged).
Please note that ACD/NMR WorkBook appears on the left hand side. This functionality is
recommended for more experienced users (see 8) and can be toggled off under the View menu.
The easy way to process raw data is to opt for the Shortcut button (toggled on/off on the left of the
Text Toolbar; see figure below) and your spectrum appears before your eyes; you can then save your
spectrum in ACD format. The layout of the processor window is labelled below.
Menus
Icon Toolbar
Text Toolbar
(context sensitive)
Window
selector
Module
selector
(context sensitive)
At this point, you can attach a structure to your spectrum by clicking (on the Module Selector)
Structure => Draw in ChemSketch or Attach from File, and select Attach structure to current
spectrum in ChemSketch.
The longer, more interactive way to spectral processing of the fid is:
1. Apply Zero Filling (double the size of original points count).
2. Apply Window Function (Using Exponential):
i. For 1H set LB = 0.3, for 13C set LB = 1.0.
3. Fourier Transform the fid.
Assignment Easiest way is by Multiplet. Point cursor from the proton of interest and to its
corresponding multiplet, a link is automatically generated and the associated proton and
multiplet are highlighted.
5) Generate a Report
Reports are used to output your spectra and generate ChemSketch files for printing, storage etc.
Click Edit => Create Report selecting either Standard or Report By Template and choose
appropriate options. If you want your own template report, you will need to create it in
Chemsketch using the small Report Template icon on the bottom left hand side selecting
appropriate boxes e.g.
If you use Standard option, the report is produced instantly and you can tailor it to your
needs.
In order to display your 1-D projections select Setup 1D Curves on the Text Toolbar.
Select Horiz. and Spectrum and select your saved proton esp file (F2), then select Vert. and
Spectrum and select a corresponding esp file (F1: 1H, 13C etc). You can scale the 1-D projections
in the scale icon e.g. 300% both horizontally and vertically. Note, whilst in Setup 1D Curves,
you can precisely align the 1-D projection peaks with their 2-D counterparts by using the crosshairs and left hand mouse button: drag from the 2D peak to the 1D peak position to align.
Note that Page Up and Page Down on your keyboard allows you to change the contour levels (or
use the mouse wheel). There are icons for block intensity plots or contour plots. The Option =>
Preferences pop-up window (above right) allows you to change contour colours, background and
numbers of contours.
Peak Picking is best done with Manual rather than Auto (which picks everthing!). You can
use the Gridlines to help you accurately pick the cross peaks. When complete you can Clear
them, as they only serve to define the peaks clearly. For heteronuclear spectra, both proton
and carbon contours are conveniently labelled on the spectrum, a feature not so easily
available in Topspin!
2-D Assignment Once peaks are picked, assignment is simply done by placing the cursor on
the cross peak and locating the two proton that are J-coupled or correlated to each other.
o Select Phase => Horiz. and place the cursor on a contour peak and horizontal crosshairs appear, click the left hand cursor and a horizontal row from the 2-D spectrum
appears, use Add to select another contour from a different part of the spectrum. Use
the Phase tabs Horizontal Ph0 (zero-order phase correction) and Ph1 (first-order phase
correction) to perform the horizontal phasing in F2 and likewise use the tabs Vertical
Ph0 and Ph1 to perform the vertical phasing in F1.
o
phase
o Having phased the spectrum, you can perform baseline correction with a noise
correction e.g.2.
7) ACD/NMR WorkBook This option is recommended for the more experienced and frequent user. It
allows you to open several spectra simultaneously in one spectral folder e.g. 1H, COSY, HSQC and 13C.
It is useful to view the demo movie: http://www.acdlabs.com/products/adh/nmr/nmr_workbook
To initialise its use, you need to go to View and ensure ACD/NMR_WorkBook is ticked, then File =>
New NMR Project, where upon a new set of icons appears in the left hand corner.
Select the icon entitled Add Raw Data from Folder (with the + sign) and tick the spectra you
require processing.
After a few seconds all the automatically processed spectra appear in tile mode on the screen. It is a
good idea to turn on the NMR Sync icon, (6th Workbook icon from the left) and the top right icon called
Synchronise which allow you to align multiplets between spectra and to attach 1-D spectra to all your
2-D spectra. The first icon on the top right toggles between different horizontal and vertical tiles, the
second one allows you to view one spectrum at a time.
Some words of warning using ACD/NMR WorkBook: The edited-HSQC spectra may not be
automatically phased correctly and will need manual phasing, there may also be extraneous 1-D
spectra taken from 2-D rows that are used by Bruker automation (eg expt. numbers 998, 999 etc)
which are inadvertently carried forward. You will need to deselect these when you open your files or
close these down afterwards, File => Close. The synchronisation of spectra is not perfect and is often
lost half-way through manipulation. The tiled views are often small and irritating.
8) Spectral User database
The use of User databases (either Group or Personal) is an extremely powerful and useful tool,
allowing you to archive your spectra with attached structures, assignments and coupling constants
from which your results can also be automatically tabulated in various Journal formats. Its application
is highly recommended.
You can toggle between Processor and Database using the Module Selector tabs at the bottom of the
screen, allowing new additions and changes to your spectrum to be updated in the Database.
The Structure User Data if double clicked allows the input of any other data using New e.g X-ray, mass
spectra, melting points, and you can also link the spectral data to other files on your computer, making
it very versatile.
Note
If a structure already exists in a database, the user will be prompted to create a new record, replace
the current record or add to the record during the update process. Remember to select the
appropriate option when this occurs. When used routinely, the database can be searched for user,
structure, name etc. and will become a very valuable archiving system for you and your group, since
each spectrum always keeps an associated structure alongside it.