Take control of your experiments. Bio-Rad’s 1000-series thermal cycling platform gives you the
power to do the experiments you want to do, the way you want to do them. The high-performance
1000-series platform can be configured to meet any researcher’s unique needs. Choose the
C1000™ cycler, the S1000™ cycler, or a combination of both. Choose from four interchangeable
reaction modules, including one for real-time PCR. Use graphical or text-based programming, optimize
experiments using the gradient feature, and transport your data with a USB flash drive. No matter how
you configure your 1000-series system, you’ll get superior thermal performance in a simple-to-use,
dependable instrument that delivers accurate results and the flexibility to expand as your research grows.
Fast
n Decrease run times and get results when you need them
n Quickly create protocols — including fast and ultrafast protocols — using the protocol autowriter
n Save time by optimizing annealing temperature in a single run using a temperature gradient
n Start running experiments immediately using the accessible interface, intuitive programming,
and helpful tools provided by onboard or PC-based software
Friendly
n Transfer data quickly and easily using the USB flash drive
n Upgrade to real-time PCR in seconds with minimal setup and factory-calibrated optics
n Get reliable results for years with durable solid-state optical components for real-time PCR
and a patented* O-ring seal that protects thermal electric modules (TEs)
n Choose the best setup for your needs with 2 chassis options and 4 interchangeable
n Expand the platform as your research grows — multi-instrument control for 2–32 thermal
cyclers or up to 4 real-time systems for high throughput
n Program, display, export, and analyze real-time PCR data the way you want to
n Use your favorite consumables — fully adjustable lid accommodates a wide range
of PCR tubes, plates, and sealers
If you’re like most researchers, you want to get results Superior Uniformity
faster. Many factors contribute to the overall time it The rate and efficiency of PCR depends critically on the
takes to get PCR results: the time to design, program, precision of the temperature steps. To obtain reliable,
and optimize a protocol, the time to run the protocol, consistent results, it is important that all wells maintain
and the time to analyze the results. Bio-Rad engineers the proper temperature throughout each incubation
have developed a complete thermal cycling system step. This is especially critical for precise quantitation
that will speed every step of your PCR process to give in real-time PCR. 1000-series thermal cyclers have
you what’s really important — a shorter time from six independently controlled TEs, the heating and
setup to results. cooling elements of the thermal cycler, to maintain
tight temperature uniformity at all points during the
Protocol autowriter — generates an optimal
run — even during ramping.
protocol based on your polymerase, primers, and
product length Rapid Arrival at Target Temperature
Thermal gradient feature — identifies optimal A key component of overall protocol run time is the time
annealing temperature in a single run to reach target temperature, which is determined by the
average ramp rate and the time for the sample block
Reduced-mass sample block — fast ramping
to reach thermal uniformity. Maximum ramp rate is less
and settling produce the shortest time to target
important, because it can fluctuate significantly during
temperature
the ramp. The C1000 and S1000 thermal cyclers’ tight
Intuitive software — makes programming faster temperature control produces high average ramp rates
and easier for PCR and real-time PCR and uniformity during ramping, to yield fast time to target
temperature and faster protocol run times.
90
85
80
Temperature, °C
75
70
65
60
55
0 20 40 60 80 100 120 140 160 180 200
Time, sec
O-ring hermetic seal extends the life of the heating and cooling
elements. Condensation from constant heating and cooling can degrade
TEs, causing them to fail. Bio-Rad’s 1000-series cyclers include a patented
O-ring seal (red in illustration) that forms an airtight barrier around the TEs,
preventing exposure to condensation. This substantially lengthens the life
of TEs and guarantees outstanding thermal performance.
What Is Flexible?
Since PCR is central to genomics research, you need a 1000-Series Reaction Modules Swap in Seconds Without Tools
flexible platform that can adapt as your research evolves.
Bio-Rad’s 1000-series cycling platform offers two chassis
options, four interchangeable reaction modules, and
96-well fast reaction module,
simple expansion capabilities, so you can create a setup
gradient enabled
that can grow with you and continue to meet your needs.
First, choose a chassis: the feature-rich C1000 thermal
cycler, the streamlined, equally powerful S1000 thermal
cycler, or a combination of the two. Next, choose one
or more reaction modules: 96 wells, 384 wells, two
independently controlled 48-well blocks, or a six-channel
optical reaction module for real-time PCR. Adding Dual 48/48 fast reaction
module, gradient enabled
instruments to increase throughput is as easy as
connecting a USB cable — up to 32 thermal cyclers
can be controlled by one computer. You can even
connect thermal cyclers and real-time PCR detection
systems, run different protocols, and start experiments
at different times.
Depending on your setup, you can also choose to: 384-well reaction module
Enter your PCR product length, primer Run, edit, or save the suggested protocol.
1 3
annealing temperature (Ta), and polymerase.
—20 kb —501 bp
—10 kb —261 bp
—167 bp
2 kb—
in
in
in
in
in
in
in
in
in
in
in
in
in
in
in
in
in
in
m
m
58
43
38
58
43
18
28
58
79
49
30
99
63
36
96
51
34
hr
hr
hr
hr
hr
hr
2
1
5
2
2
1
Protocols generated by the protocol autowriter at various standard (S), fast (F), and ultrafast (U) settings yield comparable
results. 2 kb, 10 kb and 20 kb fragments were amplified from a DNA template by iProof DNA polymerase, and various fragments up
to 501 bp in length were amplified from human genomic DNA using iTaq DNA polymerase. Equal amounts of reaction mixture were
loaded into the well for each set of amplicons. M, marker.
Thermal Cyclers
reaction module
Optimize reactions for speed using the protocol autowriter
n
user interface
Choose a reaction module that suits your needs —
n
The CFX96 optical reaction module converts a With the CFX96 system you can:
103
RFU
102
10 20 30 40
Cycles
A
n, Texas Red/IL2.
F
G
Amplification
H
16 18 20 22 24 26 28 30
Cycles
Amplification
103
101
0 10 20 30 40
Cycles
iScript™ Select cDNA Synthesis Kit iScript™ One-Step RT-PCR Kit iTaq DNA Polymerase and dNTP Mix
With SYBR® Green
iProof High-Fidelity DNA Polymerase iTaq™ SYBR® Green Supermix With ROX
Specifications
Thermal Cycler C1000 S1000
Input power 400 W, maximum 400 W, maximum
Frequency 50–60 Hz, single phase 50–60 Hz, single phase
Display 12 x 9 cm, high resolution, color LCD
Ports 5 USB A, 1 USB B 4 USB A, 1 USB B
Fuses Two 6.3 A, 250 V, 5 x 20 mm Two 6.3 A, 250 V, 5 x 20 mm
Memory >1,000 typical programs onboard, >1,000 typical programs onboard
unlimited with USB flash drive expansion
Dimensions (W x D x H) 13 x 18 x 8" 13 x 18 x 8"
Weight 23 lb 23 lb
Temperature control modes Calculated and block Calculated and block
PCR license Yes Yes
Programming options Step-based graphical, text based, Semi-graphical, text based
automatic
Security features Password-protected folders, optional Password-protected folders
log-in, and secured mode for highly
regulated environments
Reporting Exportable run logs, system error logs No
Onboard software Windows CE 6.0 No
PC compatibility Windows XP or higher Windows XP or higher, through C1000 cycler
USB peripheral compatibility Mouse, USB flash drive, bar code reader No
Real-time PCR upgrade 6-channel, 5-color CFX96 module No
Instant incubation Yes Yes
Thermal Gradient
Gradient accuracy +0.2°C of programmed temperature at end rows
Row uniformity +0.4°C well-to-well (within row) within 10 sec of arrival
at target temperature
Gradient range 30–100°C
Temperature differential range 1–24°C
Bio-Rad
Laboratories, Inc.
Life Science Web site www.bio-rad.com USA 800 4BIORAD Australia 61 02 9914 2800 Austria 01 877 89 01 Belgium 09 385 55 11 Brazil 55 21 3237 9400
Canada 905 364 3435 China 86 21 6426 0808 Czech Republic 420 241 430 532 Denmark 44 52 10 00 Finland 09 804 22 00 France 01 47 95 69 65
Group Germany 089 318 84 0 Greece 30 210 777 4396 Hong Kong 852 2789 3300 Hungary 36 1 455 8800 India 91 124 4029300 Israel 03 963 6050
Italy 39 02 216091 Japan 03 6361 7000 Korea 82 2 3473 4460 Mexico 52 555 488 7670 The Netherlands 0318 540666 New Zealand 0508 805 500
Norway 23 38 41 30 Poland 48 22 331 99 99 Portugal 351 21 472 7700 Russia 7 495 721 14 04 Singapore 65 6415 3188 South Africa 27 861 246 723
Spain 34 91 590 5200 Sweden 08 555 12700 Switzerland 061 717 95 55 Taiwan 886 2 2578 7189 United Kingdom 020 8328 2000