Professional Documents
Culture Documents
TYPE
Sentinel
Dual
SOHO
DATACENTER
E-MEDICAL
INDUSTRY
TRANSPORT
EMERGENCY
ONLINE
High Power
USB
plug
Hot swap
battery
Energy
share
Highlights
Simplified installation
Operating mode
selection
High quality output
voltage
High battery reliability
Emergency function
90
90
Simplified installation
Can be installed on the floor (tower
version) or in rack mount cabinets (rack
version). The display panel can be rotated
(using the key supplied)
Low noise (<40 dBA): can be installed
in any environment thanks to its high
frequency switching inverter and PWM
load-dependent digitally controlled fan.
External bypass option for maintenance with
interruption-free switching (5-6-8-10 kVA
SDL)
Operation guaranteed up to 40C (the
components are designed for high
temperatures and are thus subject to less
stress at normal temperatures)
Two built-in IEC output sockets with thermal
protection (5-6-8-10 kVA SDL)
On the 5-6-8-10 kVA models, it is also
possible to program two 10 A output
sockets when the mains power supply fails
(PowerShare function).
Emergency function
This configuration ensures the operation
of those emergency systems that require
continuous, reliable and long-lasting power
supply in the event of a mains power failure,
such as emergency lighting, fire detection/
extinguishing systems and alarms. When the
mains power supply fails, the inverter begins
powering the loads with a progressive startup (Soft Start) in order to prevent overload.
Battery optimisation
The wide input voltage range and a high
hold-up time minimise battery usage and
increase efficiency and battery life; for
smaller power breaks, energy is drawn from
a group of appropriately-sized capacitors.
Other features
Selectable output voltage (220-230-240 V)
Auto-restart when mains power is restored
(programmable via software)
Bypass on: when the machine is switched
off, it automatically goes into bypass and
battery charge mode
Minimum load switch-off
Low battery warning
Start-up delay
Total microprocessor control
Automatic bypass without interruption
Use of IMS modules (Insulated Metallic
Substrates)
Status, measurements and alarms
available on standard backlit display
UPS digital updating (flash upgradeable)
Input protection via resettable thermal
switch
Back-feed protection standard: to prevent
energy from being fed back to the network
Manual switching to bypass.
Advanced communications
Advanced multi-platform communications
for all operating systems and network
environments: PowerShield3 monitoring
and shutdown software for Windows
operating systems 8, 7, 2008, Vista, 2003,
XP, Linux, Mac OS X, Sun Solaris, Linux,
VMWare ESX and other Unix operating
systems
Plug and play function
USB port
RS232 serial port
Slot for installation of communications
boards.
2-YEAR WARRANTY
BATTERY BOX
BB
17
5
19
BB
0
66
17
5
0
52
DETAILS
SDL 5000
SDL 6000
USB PORT
SDL 5000
SDL 6000
SDL 8000
SDL 10000
SDL 6500 TM
SDL 8000 TM
SDL 10000 TM
SERIAL PORT
COMMUNICATIONS SLOT
INPUT SOCKET
OUTPUT SOCKETS
BATTERY EXPANSION
CONNECTOR
INPUT CABLE
ACCESS
OUTPUT CABLE
ACCESS
OPTIONS
Software
PowerShield3
PowerNetGuard
MULTI I/O
Interface kit AS400
MULTIPANEL
RTG 100
ACCESSORIES
NETMAN 101 PLUS
NETMAN 102 PLUS
NETMAN 202 PLUS
MULTICOM 301
MULTICOM 302
MULTICOM 351
MULTICOM 352
MULTICOM 372
MULTICOM 382
MULTICOM 401
Manual Bypass 16 A L
Manual bypass 16 A Rack L
Automatic bypass 16 A L
Automatic bypass 16 A Rack L
PRODUCT ACCESSORIES
Universal rails for installation in rack
cabinets
Note:
L 3300-4000 VA
BB
19
0
52
BC SDL 108-B1
630
BB
455
455
Dimensions
(mm)
4U
4U
MODELS
BB
0
66
21
5
5
65
MODELS
POWER
SDL 3300
SDL 4000
SDL 5000
SDL 6000
3300 VA/2300 W
4000 VA/2400 W
5000 VA/3500 W
6000 VA/4200 W
SDL 8000
SDL 10000
INPUT
Nominal voltage
220-230-240 Vac
Minimum voltage
Nominal frequency
50/60 Hz 5Hz
Power factor
> 0.98
Current distortion
7%
BYPASS
Voltage tolerance
Frequency tolerance
OUTPUT
Nominal voltage
Voltage distortion
Frequency
50/60 Hz selectable
Static variation
1,5%
Dynamic variation
5% in 20 ms
Waveform
Sinusoidal
Crest factor
3:1
BATTERIES
Type
Recharge time
4-6 hours
OVERLOAD TIMES
100% < Load < 110%
1 minute
4 seconds
0.5 seconds
OTHER FEATURES
Net weight (kg)
Gross weight (kg)
Dimensions (WxDxH) (mm)
Packaged dimensions
(WxDxH) (mm)
38
40
62
64
94
95
42.5
44.5
70
72
102
103
Efficiency
Line-interactive/Smart Active
Protections
98%
Overcurrent - short-circuit - overvoltage - undervoltage - temperature - excessive low battery
Communications
Input plugs
Output sockets
Standards
Terminal board
Operating temperature
0 C / +40 C
Relative humidity
Colour
Noise level at 1 m
< 45 dBA
2 cable guides; cable tips; software; serial cable;
keys for releasing display panel; handles kit
MODELS
POWER
SDL 6500 TM
SDL 8000 TM
SDL 10000 TM
6500 VA/5850 W
8000 VA/7200 W
10000 VA/9000 W
INPUT
Nominal voltage
Minimum voltage (F + N)
Nominal frequency
50/60 Hz 5 Hz
Power factor
> 0.95
BYPASS
Voltage tolerance
Frequency tolerance
OUTPUT
Nominal voltage
Voltage distortion
Frequency
50/60 Hz selectable
Static variation
1,5%
Dynamic variation
5% in 20 ms
Waveform
Sinusoidal
Crest factor
3:1
BATTERIES
Type
Recharge time
4-6 hours
OVERLOAD TIMES
100% < Load < 110%
1 minute
4 seconds
0.5 seconds
OTHER FEATURES
Net weight (kg)
91
94
95
99
102
103
Packaged dimensions
(WxDxH) (mm)
up to 98%
Protections
Communications
Input plugs
Output sockets
Standards
Operating temperature
Relative humidity
Colour
Noise level at 1 m
Standard equipment provided
RPS S.p.A.
CORMANO (MI)
Sales Office
Via Somalia, 20
20032 Cormano (Milano)
Tel +39 02 663271
Fax +39 02 66327351
ROME
Sales Office
Via Fosso della Magliana, 34/G
00148 Rome
Tel +39 06 65192125
Fax +39 06 65192247
PRE-SALES SUPPORT
(TEC)
tec@riello-ups.com
AFTER-SALES SUPPORT
(UPService)
service@riello-ups.com
DATSDLA1Y13CREN
LEGNAGO (VR)
Registered office
Viale Europa, 7 ZAI
37045 Legnago (Verona)
Tel +39 0442 635811
Fax +39 0442 629098
www.riello-ups.com
riello@riello-ups.com