Kinco HMIware v2.

2 Build140805 Release Note


Release time2014-8-7

New/Optimized function
1. Support new HMIMT4230TMT4434TMT4532T
2. Add page display function in Data Report.When there are too many data,then user can set the
quantity display in one page.
3. Add new function to display blank in Data Report when there is empty data process.
4. Add special value process in Data Report.For example,when the value is 0xFFFF(16 bits) or
0xFFFFFFFF(32 bits),if LB9400 is set as ON,then the data will display as blank.
5. Add Unicode function for user name.When LW.B 9512.0 is set as ON,then the user name in
LW9486 is considered as Unicode.
6. Add Sql function in Macro.

New/Modified PLC driver


1. Add BACnet IP BACnet MSTP Extend driver,it needs to use this version software to
update kernel and roofts of HMI.
2. Add Megmeet MC series driver,support Megmeet MC280-1616BTA4 PLC
3. Optimize ethernet driver:Modbus TCP SlaveABB AC500 Modbus TCP SlaveBosch
Rexroth L25-Ethernet slave.
4. Optimize Mitsubishi Q series (CPU Port) driver,support Mitsubishi Q06UDH CPU.
5. Optimize Mitsubishi QnA 3EBin Ethernet(TCP Slavedriver,support Q26UDV CPU.
6. Optimize Modbus RTU Extend driver.
7. Optimize SIEMENS S7-200 SMART Ethernet (TCP Slavedriver,separate s7-200 and s7-200
Smart into two drivers:SIEMENS S7-200Ethernet (TCP SlaveSIEMENS S7-200 SMART
Ethernet (TCP Slave.
8. Optimize SIEMENS MPI driver,it needs to use this version software to update kernel and
roofts of HMI.
9. Optimize SIEMENS S7-1200 Network SlaveSiemens S7-300 Network Slave driver,solved
the problem of big address of DB register read/write error and DB7 register read/write error.
10. Solve the problem of compilation error in LS XGT Ethernet driver.

Solved BUG
1. Solve the bug that when there is compilation error in Operation Log and download to HMI,it
will appear System Error at the beginning and disappear after a while.
2. Solve the bug that when there are several channels in data logger,if it exports the data logger
to CSV file and import again,the software will be crash.
3. Solve the bug that the Data report will trigger one query operation by mistake at the
beginning.
4. Solve the bug that when the memory is not enough in real time report,it will cause system
crash.
5. Solve the bug that when exporting and importing the data logger,the storage days will be not

saved.
6. Solve the bug that using address tag in macro will be problem sometimes.
7. Solve the bug that when checking the function in timer list of window attribute,the function is
different from the actual setting.
8. Solve the bug that when using vector font,HMI can not display the font sometimes after
power on.
9. Solve the bug that the limit of unsigned data in number input is abnormal.
10. Solve the bug that it can not import the csv file of event information which exported from
V2.0 software.
11. Solve the bug that when the number of events which is stored in recipe is more than 200,if
HMI restart immediately,then the date of historical event will display as 1970/01/01.
12. Solve the bug that when more than 64 events are triggered,it will loose part of the event
information.
13. Solve the bug that when touch the event information in Event Display,it will cause PLC error.
14. Solve the bug that when exporting and importing alarm information in software v2.2
build140314,it will appear errorMemory shortage.
15. Solve the bug that it will appear error when defining data type as 32 bit hexadecimal in recipe
editor.
16. Solve the bug that it will display the Chinese in reverse order when setting data type as char
in recipe editor.
17. Solve the bug that the tag in dropdown list function of Multiple states switch display over
range.
18. Solve the bug that when setting index address in numberic components,if the value of index
address is changed,then the value of other components will change into 0 instantaneously.
19. Solve the bug that when set the data type as unsigned int in multiple states setting,the
variable address can not save.
20. Solve the bug that when using Write(trigger),Write(Confirm) and
Write(Resume) in event information,the address will be mistake.
21. Solve the bug that when using SIEMENS MPI driver to communicate MT4000 series
HMI with Siemens S7-300 PLC,if the PLC is connecting to more than 2 MPI slaves,then HMI
needs to power on in different order from PLC.To solve this problem,it needs to update kernel and
roofts of HMI by this version software,and then recompile the project.