You are on page 1of 1

SCOPE OF WORK

No:

Certificate
Elevator Id No: A12050L6
Items checked
Presence of instruction manual, circuit diagram and test
certificate details

Remarks

Machine Room & Pulley Room


Access & security of the machine room
Machine room lighting
Ventilation & Temperature of the machine room
Presence of fire detectors/extinguisher
Presence of rescue operation instruction in machine room
Openings in machine room floor
Clearances
Labelling, correct notices, markings and operating
instructions
Protection and identification of electrical equipments
Main switch condition

NOT
CONNECTT
ED

Earthing condition

REC

TEMP

Emergency operation system


Emergency landing device(ELD - Battery device)
Inspection control panel unit
Machine drive unit condition
Machine brake condition and operation
Suspension rope & attachment elements condition
Protection measures at rotating equipments (Traction
sheave, pulleys & sprockets etc.)
Condition of traction sheave and pulleys
Traction Test
Balancing test
Direction & Final limit switches
Buffer switches
Over speed governor
Car safety gear
Ascending car over speed protection device
Intercom
Hoist way & Car
Car top inspection control station
Car top ventilation
Car top balustrade
Car top emergency exit/trapdoor

REM

REM

GTS-CER-3223-14

Items checked
Electrical safety devices for safety gear and
over speed governor
Car and counter weight rope condition and
termination
Governor rope condition and termination
Car and counterweight guide shoe/roller

Remarks

Trailing and shaft cables condition

Compensating chain/ropes condition


Guide rails fixing
Emergency landing door unlocking system
Strength of landing doors and locking devices

NA

Strength of the car door

Electrical safety of landing door and car door


Car and landing apron
Distance between car door sill and inner
surface of the hoist way
Car door sensor / safety edge
Car levelling
Presence of load capacity plate in car
Emergency alarm and intercom
Car normal and emergency light
Provision in ventilating the car
Lift car and landing controls and indication for
correct operation
Admitted distances
Operation of over load device
Operation under emergency (fire) condition
Car door closing force
Elevator speed and ride quality
Pit
Access to lift pit
Stopping device in the pit/pulley room
Adequate lighting in the pit/well
Buffer(car and counter weight)
Partition in the pit between lifts
Clearances & run - byes
Condition of pit
Counter weight screen

REM

NOTE 1: TEMP TEMPORARY, REC RECOMMENDATIONS, REM REMARKS, N/A- NOT APPLICABLE, NA- NOT
AVAILABLE

REMARKS / RECOMMENDATIONS
ITEMS TO BE RECTIFIED WITHOUT DELAY
Permanent power supply shall be provided.
Capacity plate missing inside the cabin shall be provided.
ELD [battery operated] not functioning shall be rectified.
Car top balustrade height is not as per the specification - height shall be
increased.
5. Head room cut-out shall be secured.
1.
2.
3.
4.

At the time of installation, there was no requirement with reference to specific standard. For improving the
safety level referring to the latest European standard BS-EN 81- 1, we recommend at least the
implementation of the following measures in medium term or together with a major modernization.
1.

SWL marking shall be done on the hoisting hooks in the head room.

Gulf Test Safety Consultancies, P.O.Box:133143, Abu Dhabi, U.A.E. Phone: 02 5575244,
Fax: 02 55758883

You might also like