BTS3012AE

Hardware Description(for FFU)

5 BTS3012AE Cables

BTS3012AE Cables

About This Chapter


This part describes the functions, structures, pins, and installation positions of BTS3012AE
cables.
5.1 List of the BTS3012AE Cables (for FFU)
BTS3012AE cables include the AC power cables, PGND cables, power cables of the DC power
distribution box, transmission cables, signal cables, RF cables, built-in battery cables (optional),
and external battery cables (optional).
5.2 Power Cables and PGND Cables for the BTS3012AE
The AC power cables for the BTS3012AE are the external input power cables of the following
types: 220 V AC 3-phase 4-core input, 220 V AC single-phase 2-core input, and 110 V AC duallive input. The PGND cables for the BTS3012AE are the PGND cables for the BTS3012AE
cabinet, transmission interface box, power interface box, front door, and back door.
5.3 Power Cable for the DC Power Distribution Box of the BTS3012AE
The power cable for the DC power distribution box of the BTS3012AE introduces power from
the DC power distribution box to each subrack in the cabinet.
5.4 Transmission Cables for the BTS3012AE
The transmission cables for the BTS3012AE are the E1 cables, optical cables, Ethernet cables,
and E1 signal transfer cables.
5.5 Signal Cables for the BTS3012AE
The signal cables for the BTS3012AE transmit the short-circuiting signals for the combiner on
the DTRU, signals between combined cabinets, signals between cabinet groups, power detection
signals, Boolean value input signals, signals between the DSCB and the DAFU, TOP1 signals
between the DCCU and the DSCB, TOP2 signals between the DCCU and the DSCB,
environment monitoring signals, RET control signals, monitoring transfer signals between the
NPMI and the DSCB, transfer signals between combined cabinets, PMU monitoring signals,
battery MCB alarm signals, AC lightning arrester alarm signals, humidity and temperature sensor
signals, door control sensor signals, smoke sensor signals, and water sensor signals.
5.6 RF Cables for the BTS3012AE
The RF cables for the BTS3012AE are the RF signal cables and RF jumpers for the BTS3012AE.
5.7 Cables for the Built-in Battery of the BTS3012AE
Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-1

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

The cables for the built-in battery are the GND cable, -48 V power cable, cable between the
wiring copper bar and the battery, cable between batteries, and signal cable for the temperature
sensor of the built-in battery.
5.8 Cable Between the BTS3012AE and the Auxiliary Equipment
The cables between the BTS3012AE and the auxiliary equipment are the signal cable for the
alarm box, power cable between the IBBS and the BTS3012AE, equipotential cable between
the IBBS and the BTS3012AE, and cables for the IBBS door control sensor and temperature
sensor.

5-2

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5.1 List of the BTS3012AE Cables (for FFU)


BTS3012AE cables include the AC power cables, PGND cables, power cables of the DC power
distribution box, transmission cables, signal cables, RF cables, built-in battery cables (optional),
and external battery cables (optional).
Table 5-1 lists the BTS3012AE cables.
Table 5-1 List of the BTS3012AE cables

Issue 01 (2007-09-10)

Item

Sub-Item

Installation
Positions

Remarks

Power cable

External input
power cable (220 V
AC 3-phase 4-core
input)

One end is from the


onsite power cable.

Refer to 5.2.1 AC Power


Cables for the
BTS3012AE.

External input
power cable (220 V
AC single-phase 2core input)

One end is from the


onsite power cable.

External input
power cable (110 V
AC dual-live input)

One end is from the


onsite power cable.

The wires L1, L2, L3,


and N of the other end
connect to the wire
posts L1, L2, L3, and
N on the AC lightning
arrester respectively.

The wires L and N of


the other end connect
to the wire posts L
(L1, L2, or L3) and N
on the AC lightning
arrester respectively.
A short-circuit copper
bar is required.

The wires L1, L2, and


N of the other end
connect to the wire
posts L1, L2, and N
on the AC lightning
arrester respectively.

Huawei Technologies Proprietary

5-3

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Item

Sub-Item

Installation
Positions

Remarks

PGND cable

PGND cable for the


BTS3012AE
cabinet

One end connects to


the corresponding
terminal on the
internal grounding
bar of the
BTS3012AE cabinet.

Refer to 5.2.2 PGND


Cables for the
BTS3012AE (AC).

The other end


connects to the
corresponding
terminal on the
external copper bar.
PGND cable for the
transmission
interface box

One end connects to


the corresponding
terminal on the
grounding bar of the
transmission
interface box.
The other end
connects to the
corresponding
terminal on the
external copper bar.

PGND cable for the


power interface box

One end connects to


the corresponding
terminal on the
grounding bar of the
power interface box.
The other end
connects to the
corresponding
terminal on the
external copper bar.

PGND cable for the


front door

One end connects to


the cabinet.
The other end
connects to the front
door of the cabinet.

PGND cable for the


back door

One end connects to


the cabinet.
The other end
connects to the back
door of the cabinet.

5-4

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Item

Sub-Item

Installation
Positions

Remarks

Equipotential
cable

Equipotential cable

One end connects to


the PGND bar at the
bottom of a cabinet.

Refer to 5.2.3
Equipotential Cable of
the BTS.

The other end


connects to the PGND
bar at the bottom of
another cabinet.
Power cable of
the DC power
distribution box

Issue 01 (2007-09-10)

Power cable
between the DC
power distribution
box and the DTRU
subrack

One end connects to


ports 16 on the DC
power distribution
box.

Power cable
between the DC
power distribution
box and the DAFU
subrack

One end connects to


port 7 or 8 on the DC
power distribution
box.

Power cable
between the DC
power distribution
box and the common
subrack

One end connects to


port 10 on the DC
power distribution
box.

Power cable
between the DC
power distribution
box and the fan
subrack

One end connects to


port 11 on the DC
power distribution
box.

The other end


connects to the PWR
ports on DTRUs 05.

The other end


connects to the PWR
ports on the DDPUs
or the DC-IN-48V
ports on the DFCUs in
the DAFU subrack.

The other end


connects to the
POWER port on the
DCCU.

The other end


connects to the PWR
port on the FAN Box
panel.

Huawei Technologies Proprietary

There are six independent


power cables between the
DC power distribution
box and the DTRU
subrack. Refer to 5.3.1
BTS3012AE Power
Cables Between the DC
Power Distribution Box
and the DTRU Subrack.
There are two
independent power cables
between the DC power
distribution box and the
DAFU. Refer to 5.3.2
BTS3012AE Power
Cables Between the DC
Power Distribution Box
and the DAFU Subrack.

Refer to 5.3.3
BTS3012AE Power
Cable Between the DC
Power Distribution Box
and the Common
Subrack.

Refer to 5.3.4
BTS3012AE Power
Cable Between the DC
Power Distribution Box
and the Fan Subrack.

5-5

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Item

Transmission
cables

Sub-Item

Installation
Positions

Remarks

Power cable
between the DC
power distribution
box and the fan filter
unit

One end connects to


the DC Power port on
the fan filter unit at
the front door.

Refer to 5.3.5
BTS3012AE Power
Cable Between the DC
Power Distribution Box
and the Fan Filter Unit.

E1 cable

One end connects to


the TR port on the
DELU.

The other end


connects to switch 12
on the DC power
distribution box.

Refer to 5.4.1 E1 Cable of


the BTS3012/
BTS3012AE.

The other end


connects to the
transmission device
such as transmission
interface box.
Optical cable

One end connects to


the optical
transmission device
such as Metro100.

Refer to 5.4.2 Optical


Cable of the BTS3012/
BTS3012AE.

The other end


connects to the
transmission
interface box such as
Optical Distribution
Frame (ODF).
Ethernet cables

One end connects to


the MMI port on the
DTMU panel. The
other end connects to
the HUB.
Alternatively, one
end connects to the
Ethernet port on the
LMT computer and
the other end connects
to a HUB.

Refer to 5.4.3 Ethernet


Cable of the BTS3012/
BTS3012AE.

Crossover cable: One


end connects to the
MMI port on the
DTMU panel and the
other end connects to
the Ethernet port on
the LMT PC.

5-6

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Item

5 BTS3012AE Cables

Sub-Item

Installation
Positions

Remarks

E1 signal transfer
cable

One end connects to


the TO DCCU E1 port
on the DSCB.

Refer to 5.4.4 E1 Signal


Transfer Cable for the
BTS3012AE.

The other end


connects to the TRAN
port on the DCCU.
Signal cables

Cable for combiner


on the DTRU

One end connects to


the TX1 or TX2 port
on the DTRU.
The other end
connects to the IN1 or
IN2 port on the
DTRU.

Refer to 5.5.1 Combining


Short-Circuiting Signal
Cable of the BTS3012/
BTS3012AE.

Power detection
cable

One end connects to


the PF out/PR out port
on the DFCU panel.
The other end
connects to the PF in/
PR in port on the
DFCU panel.

Refer to 5.5.2 Power


Detection Cable of the
BTS3012/BTS3012AE.

Four-in-one shortcircuiting cable

One end connects to


the COM port on the
DFCU panel.
The other end
connects to the TXDUP port on the
DFCU panel.

Refer to 5.5.16 Four-InOne Short-Circuiting


Cable of the BTS3012/
BTS3012AE.

Diversity receive
short-circuiting
cable

One end connects to


the RXD-OUT port
on the DFCU panel.
The other end
connects to the HL-IN
port on the DFCU
panel.

Refer to 5.5.15 Diversity


Receive ShortCircuiting Cable of the
BTS3012/BTS3012AE.

Signal cable
between combined
cabinets

One end connects to


port TO SLAVE
CABINET on the
DSCB in one cabinet.

Refer to 5.5.3 Signal


Cable for Combined
Cabinets of the
BTS3012/BTS3012AE .

The other end


connects to port TO
SLAVE CABINET
on the DSCB in the
other cabinet.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-7

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Item

Sub-Item

Installation
Positions

Remarks

Signal cable
between cabinet
groups

One end connects to


the TO SLAVE
GROUP1 or TO
SLAVE GROUP2
port on the DSCB in
one cabinet group.

Refer to 5.5.4 Signal


Cable for Cabinet
Groups of the BTS3012/
BTS3012AE.

The other end


connects to the TO
SLAVE GROUP1 or
TO SLAVE
GROUP2 port on the
DSCB in another
cabinet group.
Far signal cable
between cabinet
groups

One end connects to


the CKB port on the
DGLU in the main
cabinet group.

Refer to 5.5.5 Far Signal


Cable Between
BTS3012AE Cabinet
Groups.

The other end


connects to the CKB
port on the DGLU in
the extension cabinet
group.
Boolean input signal
cable

One end connects to


the external device.
The other end
connects to the SW
IN/OUT port on the
DMLU.

RET control signal


cable

One end connects to


the port on the
DATU.
The other end
connects to the BiasTee port.

Signal cable
between the DSCB
and the DAFU
subrack

One end connects to


the TO DAFU 0-2 or
TO DAFU 3-5 on the
DSCB.
The other end
connects to the COM/
ONSHELL ports on
the DDPU/DCOM
panels in the DAFU
subrack.

5-8

Huawei Technologies Proprietary

Refer to 5.5.6 Boolean


Input Cable of the
BTS3012AE.

Refer to 5.5.13 RET


Control Signal Cable of
the BTS3012/
BTS3012AE.

There are two same signal


cables from the DSCB to
the DAFU subrack. These
two cables are the same.
Refer to 5.5.7 Signal
Cables Between the
DSCB and the DAFU
Subrack in the
BTS3012AE .

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Item

5 BTS3012AE Cables

Sub-Item

Installation
Positions

Remarks

TOP1 signal cable


between the DCCU
and the DSCB

One end connects to


the TOP (FROM
DCCU) port on the
DSCB.

Refer to 5.5.8 TOP1


Signal Cable Between
the DCCU and the
DSCB in the
BTS3012AE.

The other end


connects to the
TO_TOP1 port on the
DCCU.
TOP2 signal cable
between the DCSU
and the DSCB

One end connects to


the TOP2 port on the
DCSU.
The other end
connects to the TO
DCSU TOP port on
the DSCB.

Signal transfer cable


for combined
cabinets

One end connects to


the TO SLAVE
MASTER (FROM
DCSU) port on the
DSCB.

Refer to 5.5.9 TOP2


Signal Cable Between
the DCSU and the DSCB
in the BTS3012AE .

Refer to 5.5.11 Signal


Transfer Cable Between
BTS3012AE Combined
Cabinets.

The other end


connects to the
CC_IN or CC_OUT
port on the DCSU.
Signal cable
between the DCSU
and the DTRB

One end connects to


the TO_DTRB port
on the DCSU.
The other end
connects to the port
on the DTRB.

RS485 environment
monitoring signal
cable

One end connects to


the To_FAN port on
the DCCU.
The other end
connects to the RJ45
port on the DPMU
panel, the COM Port
on the fan filter unit
on the front door, the
COM port on the
FAN Box, and the
sensor on the left of
the air inlet.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

Refer to 5.5.10 Signal


Cable Between the
DCSU and the DTRB in
the BTS3012/
BTS3012AE.

Refer to 5.5.12 RS485


Environment
Monitoring Signal
Cable for the
BTS3012AE.

5-9

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Item

Sub-Item

Installation
Positions

Remarks

Monitoring transfer
cable between the
NPMI and the
DSCB

One end connects to


the port on the NPMI.

Refer to 5.5.14
Monitoring Transfer
Signal Cable Between
the NPMI and the DSCB
in the BTS3012AE .

Signal cable
between the DFCB
and the DFCU

One end connects to


the COM-IN port on
the panel of the
DFCU.

The other end


connects to the TO
NPMI port on the
DSCB.

The other end


connects to the
COM1 or COM2 port
on the panel of the
DFCB.
DPMU monitoring
cable

One end connects to


the COM port on the
DPMU module.

Refer to 5.5.17 Signal


Cable Between the
DFCB and the DFCU in
the BTS3012/
BTS3012AE.

Refer to 5.5.18 DPMU


Monitoring Cable for
the BTS3012AE .

The other end


connects to the J1 port
on the NPMI.
Alarm cable for the
MCB of the battery

One end connects to


the MCB terminal
near the battery.
The other end
connects to the
FU_ALM port of the
NPMI on the top of
the cabinet.

Alarm cable for the


AC lightning
arrester

One end connects to


the AC lightning
arrester.
The other end
connects to the JTD3
port of the NPMI on
the top of the cabinet.

Signal cable for the


humidity and
temperature sensor

One end connects to


the temperature and
humidity sensor.
The other end
connects to the
TEM_HUM port of
the NPMI on the top
of the cabinet.

5-10

Huawei Technologies Proprietary

Refer to 5.5.19 Alarm


Cable for the MCB of
the BTS3012AE
Battery.

Refer to 5.5.20 Alarm


Cable for the
BTS3012AE Lightning
Arrester.

Refer to 5.5.21 Signal


Cable for the Humidity
and Temperature
Sensor of the
BTS3012AE.

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Item

5 BTS3012AE Cables

Sub-Item

Installation
Positions

Remarks

Signal cable for the


door control sensor

One end connects to


the door status sensor.

Refer to 5.5.22 Signal


Cable for the Door
Control Sensor of the
BTS3012AE.

The other end


connects to the
DOOR port of the
NPMI on the top of
the cabinet.
Signal cable for the
smoke sensor

One end connects to


the water sensor.
The other end
connects to the
SMOKE port of the
NPMI on the top of
the cabinet.

Signal cable for the


water sensor

One end connects to


the water sensor.
The other end
connects to the
WATER port of the
NPMI on the top of
the cabinet.

RF cables

RF signal cable

1/4-inch RF jumper

Consists of the RF TX
signal cable and the
RF RX signal cable.
l

The RF TX signal
cable connects the
TX port on the
DTRU and the
corresponding TX
port on the DDPU.

The RF RX signal
cable connects the
RX port on the
DTRU and the
corresponding RX
port on the DDPU.

One end connects to


the ANTA or ANTB
port on the top of the
DDPU.

Refer to 5.5.23 Signal


Cable for the Smoke
Sensor of the
BTS3012AE.

Refer to 5.5.24 Cable for


the Water Sensor of the
BTS3012AE.

Refer to 5.6.1 RF Signal


Cables of the BTS3012/
BTS3012AE.

Refer to 5.6.2 RF
Jumpers for the
BTS3012AE.

The other end at the


bottom of the cabinet
connects to the 1/2inch RF jumper.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-11

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Item

Sub-Item

Installation
Positions

1/2-inch RF jumper

One end at the bottom


of the cabinet
connects to the 1/4inch RF jumper.

Remarks

The other end


connects to the
feeder.

GND cable

48 V power cable

Cable for builtin batteries


(optional)

Cable between the


wiring copper bar
and the storage
batteries

Cable between
storage batteries

5-12

One end connects to


the positive lead of
the wiring copper bar
on the left part in the
50 AH battery cabin

Refer to 5.7 Cables for


the Built-in Battery of
the BTS3012AE.

The other end


connects to the RTN
on the back of the
power supply
subrack.
One end connects to
the negative lead of
the wiring copper bar
on the left part in the
50 AH battery cabin.
The other end
connects to the RTN
on the back of the
power supply
subrack.
One end connects to
the wiring copper bar
on the left part in the
50 AH battery cabin.
The other end
connects to the
positive or negative
lead of the storage
batteries.
The red connector
connects to the
positive lead of one
storage battery.
The black connector
connects to the
negative lead of the
other storage battery.

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Item

5 BTS3012AE Cables

Sub-Item

Installation
Positions

Remarks

One end (OT


terminal):

Cable for the


temperature sensor
of the built-in
batteries

If the BTS3012AE
is configured with
the 200 AH built-in
batteries, the OT
terminal connects
to the positive
terminal on the left
storage battery in
the front row
within the 50 AH
battery cabin.

If the BTS3012AE
is configured with
the 100 AH or 150
AH built-in
batteries, the OT
terminal connects
to the positive
terminal on the left
storage battery in
the front row at the
upper layer within
the 150 AH battery
cabin.

The common 2-pin


connector connects to
port BAT_TEM1 on
the NPMI.

Cable between
the
BTS3012AE
and the
auxiliary
equipment

Issue 01 (2007-09-10)

One end connects to


the positive lead of
the wiring copper bar
for the external
battery cabinet.
GND cable

Refer to 5.8.2 Power


Cables Between the
IBBS and the
BTS3012AE .

The other end


connects to the RTN/
+ terminal of the
wiring copper bar for
the 48 V 50 AH
battery cabin in the
BTS3012AE cabinet .

Huawei Technologies Proprietary

5-13

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Item

Sub-Item

Installation
Positions

Remarks

One end connects to


the negative lead of
the wiring copper bar
for the external
battery cabinet.
48 V power cable

The other end


connects to the 48 V
terminal of the wiring
copper bar for the 48
V 50 AH battery
cabin in the
BTS3012AE cabinet .

Signal cable in the


external
environment alarm
box

One end connects to


the COM1 or COM2
port on the DSAC on
the top of the cabinet.

Refer to 5.6.2 RF
Jumpers for the
BTS3012AE.

The two wires at the


other end connect to
the relevant control
device.
Equipotential cable

One end connects to


the grounding bar
terminal in the
external battery
cabinet.

Refer to 5.8.3
Equipotential Cable
Between the IBBS and
the BTS3012AE .

The other end


connects to the
grounding bar of the
BTS3012AE cabinet.
Cable for the Door
Control Sensor and
Temperature Sensor

The four bare wires


connect to the wiring
terminal of the
external battery
cabinet.

Refer to 5.8.4 Cable for


the Door Control Sensor
and Temperature
Sensor.

The 2-pin connector


at the other end
connects to the port
BAT_TEM2 on the
NPMI. The two bare
wires connect to the
cable for the door
control sensor on the
BTS3012AE cabinet.

5-14

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

NOTE

The combining short-circuiting signal cable is not required when the DTRU (type B) is used. The combining
short-circuiting signal cable is used only for the internal combining of the DTRU (type A).

5.2 Power Cables and PGND Cables for the BTS3012AE


The AC power cables for the BTS3012AE are the external input power cables of the following
types: 220 V AC 3-phase 4-core input, 220 V AC single-phase 2-core input, and 110 V AC duallive input. The PGND cables for the BTS3012AE are the PGND cables for the BTS3012AE
cabinet, transmission interface box, power interface box, front door, and back door.
5.2.1 AC Power Cables for the BTS3012AE
The AC power cables for the BTS3012AE are the external input power cables of the following
types: 220 V AC 3-phase 4-core input, 220 V AC single-phase 2-core input, and 110 V AC duallive input.
5.2.2 PGND Cables for the BTS3012AE (AC)
The PGND cables for the BTS3012AE are the PGND cables for the BTS3012AE cabinet,
transmission interface box, power interface box, front door, and back door.
5.2.3 Equipotential Cable of the BTS
This part describes the function, structure, pin assignment, and installation positions of the
equipotential cable.

5.2.1 AC Power Cables for the BTS3012AE


The AC power cables for the BTS3012AE are the external input power cables of the following
types: 220 V AC 3-phase 4-core input, 220 V AC single-phase 2-core input, and 110 V AC duallive input.

Function
The AC power cable is used to transmit 220 V AC or 110 V AC power from the power interface
box to the external power connecting terminal of the power lightning arrestor in the cabinet. The
BTS3012AE supports three power input modes: 220 V AC 3-phase input, 220 V AC singlephase input, and 110 V AC dual-live input.

Appearance
NOTE

The AC power cables for the BTS3012AE are available at local markets. The colors of the cables
must comply with the local rules and regulations.

If the local rules and regulations have no special requirements pertaining to the color of the cable,
use the cables that are delivered with the BTS.

The L wire is red and the N wire is black by default. The OT terminals of AC power cables are made
on site.

The AC power cables are prepared on site. Table 5-2 lists the specifications for the AC power
cables.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-15

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-2 Specifications for the AC power cables


Power Input
Mode

Cable

Quantity

Sectional
Area

Color

220 V AC 3-phase
4-core input

10 mm2

Red

10 mm2

Black

220 V AC singlephase 2-core input

16 mm2

Red

16 mm2

Black

110 V AC dual-live L
input
N

16 mm2

Red

16 mm2

Black

Pin Description
None

Installation Positions
The three types of AC power cables are routed into a BTS3012AE cabinet through the cable
hole for the external power cable at the bottom of the cabinet, and then connected to the wire
post on the AC power lightning arrestor. Table 5-3 describes the installation positions.
Table 5-3 Installation positions of the AC Power Cables
Power Input Mode

Power Cable

Installation Position

220 V AC 3-phase 4core input

L1

Wire post with the AC lightning arrester


labeled with L1

L2

Wire post with the AC lightning arrester


labeled with L2

L3

Wire post with the AC lightning arrester


labeled with L3

Wire post with the AC lightning arrester


labeled with N

Wire post with an AC lightning arrester


labeled with L1, L2, or L3 (A shortcircuiting copper busbar is required.)

Wire post with the AC lightning arrester


labeled with N

L1

Wire post with the AC lightning arrester


labeled with L1

L2

Wire post with the AC lightning arrester


labeled with L2

220 V AC singlephase 2-core input

110 V AC dual-live
input

5-16

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Power Input Mode

5 BTS3012AE Cables

Power Cable

Installation Position

Wire post with the AC lightning arrester


labeled with N

5.2.2 PGND Cables for the BTS3012AE (AC)


The PGND cables for the BTS3012AE are the PGND cables for the BTS3012AE cabinet,
transmission interface box, power interface box, front door, and back door.

Function
The PGND cables keep the cabinet well grounded.
l

The PGND cables for the BTS3012AE cabinet ensures proper grounding of the whole
cabinet.

The PGND cables in the transmission interface box that are used to keep this box well
grounded.

The PGND cables in the power interface box are used to keep this box well grounded.

The PGND cable for the front door ensures the proper grounding of the front door.

The PGND cable for the back door ensures the proper grounding of the back door.

Appearance
The PGND cables for the BTS3012AE cabinet, front door, and back door are green and yellow
cables with a cross-sectional area of 25 mm2. If you decide to prepare the cable by yourself,
choose a green and yellow cable with a plastic insulation copper core and with a cross-sectional
area of at least 25 mm2.
The PGND cables for the transmission interface box and the power interface box are yellow and
green in color with a cross-sectional area of 16 mm2. If you prepare the cable, it should be a
green and yellow cable with a plastic insulation copper core and with a cross-sectional area of
at least 16mm2.

Pin Description
None

Installation Positions
Table 5-4 shows the installation positions of the PGND cables for the BTS3012AE.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-17

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-4 Installation positions of the PGND cables for the BTS3012AE
Cable Type

One End

The Other End

PGND cable for the


BTS3012AE cabinet

One end connects to


the corresponding
terminal on the
internal grounding
bar of the
BTS3012AE
cabinet.

The other end connects to the


corresponding terminal on the external
copper bar.

PGND cable for the


transmission interface
box

One end connects to


the corresponding
terminal on the
grounding bar of the
transmission
interface box.

The other end connects to the


corresponding terminal on the external
copper bar.

PGND cable for the


power interface box

One end connects to


the corresponding
terminal on the
grounding bar of the
power interface box.

The other end connects to the


corresponding terminal on the external
copper bar.

PGND cable for the


front door

One end connects to


the cabinet.

The other end connects to the front door of


the cabinet.

PGND cable for the


back door

One end connects to


the cabinet.

The other end connects to the back door of


the cabinet.

5.2.3 Equipotential Cable of the BTS


This part describes the function, structure, pin assignment, and installation positions of the
equipotential cable.

Function
The equipotential cable helps keep an equal potential between the cabinets and ensuring the safe
operation of the BTSs.

Structure
The equipotential cable is a green and yellow cable with cross-sectional area of 25 mm2. Both
ends of the cable use OT terminals. See Figure 5-1 for details.
Figure 5-1 Structure of the equipotential cable

Pin Assignment
None.
5-18

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Installation Positions
Table 5-5 describes the installation positions of the equipotential cable.
Table 5-5 Installation positions of the equipotential cable
Cabinet Model

One End (OT


Terminal)

Other End (OT Terminal)

BTS3012

Connects to the PGND


bar on top of one
cabinet

Connects to the PGND bar on top of


the other cabinet

BTS3012AE

Connects to the PGND


bar at the bottom of one
cabinet

Connects to the PGND bar at the


bottom of the other cabinet

BTS3006C

Connects to the PGND


bar at the back of one
cabinet

Connects to the PGND bar at the back


of the other cabinet

BTS3002E

Connects to one
external PGND bar

Connects to the other external PGND


bar

5.3 Power Cable for the DC Power Distribution Box of the


BTS3012AE
The power cable for the DC power distribution box of the BTS3012AE introduces power from
the DC power distribution box to each subrack in the cabinet.
5.3.1 BTS3012AE Power Cables Between the DC Power Distribution Box and the DTRU
Subrack
The power cables between the DC power distribution box and the DTRU subrack introduce
power from the DC power distribution box to the DTRU subrack. The power cables supply
power to the DTRUs in the DTRU subrack.
5.3.2 BTS3012AE Power Cables Between the DC Power Distribution Box and the DAFU
Subrack
The power cables between the DC power distribution box and the DAFU subrack introduce
power from the DC power distribution box to the DAFU subrack. The power cables supply
power to the DDPUs or DFCUs in the DAFU subrack.
5.3.3 BTS3012AE Power Cable Between the DC Power Distribution Box and the Common
Subrack
The power cable between the DC power distribution box and the common subrack introduces
power from the DC power distribution box to the common subrack. The power cable supplies
power to the common subrack.
5.3.4 BTS3012AE Power Cable Between the DC Power Distribution Box and the Fan Subrack
The power cable between the DC power distribution box and the fan subrack introduces power
from the DC power distribution box to the fan subrack. The power cable supplies power to the
fan subrack.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-19

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5.3.5 BTS3012AE Power Cable Between the DC Power Distribution Box and the Fan Filter
Unit
The power cable between the DC power distribution box and the fan filter unit leads the power
to the control board of the fan filter unit.

5.3.1 BTS3012AE Power Cables Between the DC Power Distribution


Box and the DTRU Subrack
The power cables between the DC power distribution box and the DTRU subrack introduce
power from the DC power distribution box to the DTRU subrack. The power cables supply
power to the DTRUs in the DTRU subrack.

Functions
The power cables between the DC power distribution box and the DTRU subrack introduce
power from the DC power distribution box to the DTRU subrack. The power cables supply
power to the DTRUs in the DTRU subrack.

Appearance
The power cables between the DC power distribution box and the DTRU subrack are six
independent cables. Each DTRU is configured with one independent power cable. The six cables
have the save structure, as shown in Figure 5-2.
Figure 5-2 Power cable between the DC power distribution box and the DTRU subrack
View A 1
A1
A2
A3

2 View B

W1
W2

A1
A2
A3

X2

X1
(1) 3V3 power connector

(2) 3V3 power connector

Pin Assignment
Table 5-6 lists the pin assignment of the cables between the DC power distribution box and the
DTRU subrack.
Table 5-6 Pin assignment of the cables between the DC power distribution box and the DTRU
subrack

5-20

Wire

X1 End

X2 End

Wire Color

W1

X1.A1

X2.A1

Black

W2

X1.A3

X2.A3

Blue

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Installation Positions
The power cables between the DC power distribution box and the DTRU subrack are six
independent cables. Table 5-7 shows the installation positions of the power cables.
Table 5-7 Installation positions of the cable between the DC power distribution box and DTRU
subrack
Cable Name

One End (3V3 Power


Connector)

The Other End (3V3 Power


Connector)

Cable between the DC


power distribution box
and DTRU 0

Connects to 3V3 power


connector 1 (numbered from
the top to the bottom) on the
DC power distribution box

Connects to port PWR on the


front panel of the DTRU in slot
0 of the DTRU subrack

Cable between the DC


power distribution box
and DTRU 1

Connects to 3V3 power


connector 2 on the DC power
distribution box

Connects to port PWR on the


front panel of the DTRU in slot
1 of the DTRU subrack

Cable between the DC


power distribution box
and DTRU 2

Connects to 3V3 power


connector 3 on the DC power
distribution box

Connects to port PWR on the


front panel of the DTRU in slot
2 of the DTRU subrack

Cable between the DC


power distribution box
and DTRU 3

Connects to 3V3 power


connector 4 on the DC power
distribution box

Connects to port PWR on the


front panel of the DTRU in slot
3 of the DTRU subrack

Cable between the DC


power distribution box
and DTRU 4

Connects to 3V3 power


connector 5 on the DC power
distribution box

Connects to port PWR on the


front panel of the DTRU in slot
4 of the DTRU subrack

Cable between the DC


power distribution box
and DTRU 5

Connects to 3V3 power


connector 6 on the DC power
distribution box

Connects to port PWR on the


front panel of the DTRU in slot
5 of the DTRU subrack

5.3.2 BTS3012AE Power Cables Between the DC Power Distribution


Box and the DAFU Subrack
The power cables between the DC power distribution box and the DAFU subrack introduce
power from the DC power distribution box to the DAFU subrack. The power cables supply
power to the DDPUs or DFCUs in the DAFU subrack.

Functions
The power cables between the DC power distribution box and the DAFU subrack introduce
power from the DC power distribution box to the DAFU subrack. The power cables supply
power to the DDPUs or DFCUs in the DAFU subrack.

Appearance
Two cables are connected between the DC power distribution box and the DAFU subrack. Each
cable has one connector at one end and three connectors at the other end. The one-connector end
connects to the DC power distribution box and the 3-connector end to the DAFU subrack and
Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-21

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

supplies power to the three DDPUs or DFCUs. The two cables have the same structure, as shown
in Figure 5-3.
Figure 5-3 Power cable between the DC power distribution box and the DAFU subrack
1
W1
2 View B

W2
X1
View A
A1
A2
A3

W3

W4
X2

W5

A1
A2
A3

X4

W6
X3

(1) 3V3 power connector

(2) 3V3 power connector

Pin Assignment
Table 5-8 lists the pin assignment of the cables between the DC power distribution box and the
DAFU subrack.
Table 5-8 Pin assignment of the cables between the DC power distribution box and the DAFU
subrack
Wire

One End

Other End

Wire Color

W1

X1.A1

X4.A1

Black

W3

X2.A1

Black

W5

X3.A1

Black

W2

X1.A3

W4

X2.A3

Blue

W6

X3.A3

Blue

X4.A3

Blue

Installation Positions
Table 5-9 lists the installation positions of the cables between the DC power distribution box
and the DAFU subrack.

5-22

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-9 Installation positions of the cables between the DC power distribution box and the
DAFU subrack
Cable Name

One End (3V3 Power


Connector)

The Other End (3V3 Power


Connector)

Cable between the


DC power
distribution box
and DAFU0,
DAFU2, and
DAFU4

Connects to 3V3 power


connector 7 on the DC power
distribution box

Connects to the PWR port on the


DDPU panel or the DC-IN-48V port
on the DFCU panel in the DAFU
subrack

Cable between the


DC power
distribution box
and DAFU1,
DAFU3, and
DAFU5

Connects to 3V3 power


connector 8 on the DC power
distribution box

5.3.3 BTS3012AE Power Cable Between the DC Power Distribution


Box and the Common Subrack
The power cable between the DC power distribution box and the common subrack introduces
power from the DC power distribution box to the common subrack. The power cable supplies
power to the common subrack.

Functions
The power cable between the DC power distribution box and the common subrack introduces
power from the DC power distribution box to the common subrack. The power cable supplies
power to the common subrack.

Appearance
Only one power cable is connected between the DC power distribution box and the common
subrack. Figure 5-4 shows the structure of the power cable.
Figure 5-4 Power cable between the DC power distribution box and the common subrack
View A 1
A1
A2
A3

2 View B

W1
W2
X2

X1
(1) 3V3 power connector

Issue 01 (2007-09-10)

A1
A2
A3

(2) 3V3 power connector

Huawei Technologies Proprietary

5-23

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Pin Assignment
Table 5-10 lists the pin assignment of the cable between the DC power distribution box and the
common subrack.
Table 5-10 Pin assignment of the cable between the DC power distribution box and the common
subrack
Wire

X1 End

X2 End

W1

X1.A1

X2.A1

W2

X1.A3

X2.A3

Installation Positions
Table 5-11 lists the installation positions of the cable between the DC power distribution box
and the common subrack.
Table 5-11 Installation positions of the cable between the DC power distribution box and the
common subrack
Cable Name

One End (3V3 Power


Connector)

The Other End (3V3


Power Connector)

Cable between the DC power


distribution box and the
common subrack

Connects to 3V3 power


connector 10 on the DC
power distribution box

Connects to port POWER on


the front panel of the DCCU

5.3.4 BTS3012AE Power Cable Between the DC Power Distribution


Box and the Fan Subrack
The power cable between the DC power distribution box and the fan subrack introduces power
from the DC power distribution box to the fan subrack. The power cable supplies power to the
fan subrack.

Functions
The power cable between the DC power distribution box and the fan subrack introduces power
from the DC power distribution box to the fan subrack. The power cable supplies power to the
fan subrack.

Appearance
Figure 5-5 shows the structure of the power cable between the DC power distribution box and
the fan subrack.

5-24

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-5 Power cable between the DC power distribution box and the fan subrack
View A 1
A1
A2
A3

2 View B

W1
W2

A1
A2
A3

X2

X1
(1) 3V3 power connector

(2) 3V3 power connector

Pin Assignment
Table 5-12 lists the pin assignment of the cable between the DC power distribution box and the
fan subrack.
Table 5-12 Pin assignment of the cable between the DC power distribution box and the fan
subrack
Core Wire

X1 End

X2 End

Core Color

W1

X1.A1

X2.A1

Black

W2

X1.A3

X2.A3

Blue

Installation Positions
Table 5-13 lists the installation positions of the cable between the DC power distribution box
and the fan subrack.
Table 5-13 Installation positions of the cable between the DC power distribution box and the
fan subrack
Cable Name

One End (3V3 Power


Connector)

The Other End (3V3 Power


Connector)

Cable between the


DC power
distribution box and
the fan subrack

Connects to 3V3 power


connector 11 on the DC
power distribution box

Connects to port PWR on the front


panel of the fan box

5.3.5 BTS3012AE Power Cable Between the DC Power Distribution


Box and the Fan Filter Unit
The power cable between the DC power distribution box and the fan filter unit leads the power
to the control board of the fan filter unit.

Function
The power cable between the DC power distribution box and the fan filter unit leads the power
to the control board of the fan filter unit.
Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-25

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Appearance
Figure 5-6 shows the structure of the power cable between the DC power distribution box and
the fan filter unit.
Figure 5-6 Power cable between the DC power distribution box and the fan filter unit
2 View B

View A 1
A1
A2
A3

W1
W2

A1
A2
A3

X2

X1
(1) 3V3 power connector

(2) 3V3 power connector

Pin Assignment
Table 5-14 lists the pin assignment of the power cable between the DC power distribution box
and the fan filter unit.
Table 5-14 Pin assignment of the power cable between the DC power distribution box and the
fan filter unit
Wire

X1 End

X2 End

Wire Color

W1

X1.A1

X2.A1

Black

W2

X1.A3

X2.A3

Blue

Installation Positions
Table 5-15 lists the installation positions of the power cable between the DC power distribution
box and the fan filter unit.
Table 5-15 Installation positions of the power cable between the DC power distribution box and
the fan filter unit
Cable Name

One End (3V3 Power


Connector)

The Other End (3V3 Power


Connector)

Power cable
between the DC
power distribution
box and the fan filter
unit

Connects to 3V3 power


connector 12 on the DC
power distribution box

Connects to the DC port on the control


board of the fan filter unit

5.4 Transmission Cables for the BTS3012AE


The transmission cables for the BTS3012AE are the E1 cables, optical cables, Ethernet cables,
and E1 signal transfer cables.

5-26

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5.4.1 E1 Cable of the BTS3012/BTS3012AE


This part describes the function, structure, pin assignment, and installation positions of the 75ohm and 120-ohm E1 cables.
5.4.2 Optical Cable of the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the
optical cable of the BTS3012/BTS3012AE.
5.4.3 Ethernet Cable of the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the
Ethernet cables. There are two types of Ethernet cables: straight-through cable and crossover
cable.
5.4.4 E1 Signal Transfer Cable for the BTS3012AE
The E1 signal transfer cable transfers four routes of E1 signals from the DSCB to the DCCU of
the cabinet.

5.4.1 E1 Cable of the BTS3012/BTS3012AE


This part describes the function, structure, pin assignment, and installation positions of the 75ohm and 120-ohm E1 cables.

Function
The 75-ohm E1 cable and 120-ohm cable are used to transmit the E1 trunk signal outside the
cabinet.

Structure
The 75-ohm E1 cable is a coaxial cable that consists of eight sub coaxial cables. Every two sub
coaxial cables form one E1 route. Therefore, each 75-ohm E1 cable provides four E1 routes.
The 75-ohm cable uses a DB25 male connector at one end. The other end of the cable is bare.
The connectors should be made on site. Figure 5-7 shows the 75-ohm E1 cable.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-27

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-7 Structure of the 75-ohm E1 cable


2

W1
W2

W3
W4

W5
Pos.1

W6

X0

W7
W8
A

X1

X2

X3
X4

X5
X6
X7
X8

Pos.25

(1) DB25 male connector (X0)

(2) 75-ohm E1 coaxial wire (X1X8)

(3) Coaxial core (tip)

(4) Outer conductor (ring, that is, shielding layer)

The 120-ohm E1 cable consists of four pairs of 120-ohm twisted pairs. Each pair forms one E1
route. Therefore, each 120-ohm E1 cable provides four E1 routes. The 120-ohm cable uses a
DB25 male connector at one end. The other end of the cable is bare. The connectors should be
made on site. Figure 5-8 shows the structure of the cable.
Figure 5-8 Structure of the 120-ohm E1 cable

(1) DB25 male connector (X0)

(2) 120-ohm E1 twisted pair (X1X8)

Pin Assignment
Table 5-16 describes the pin assignment for the 75-ohm E1 cable and the 120-ohm cable.
5-28

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-16 Pin assignment for the E1 cable


Core
Wire

Coaxial Cable Wire/


Outer Conductor

Pin of the DB25 Connector

Coaxial Cable
Label

W1

X1.tip

X0.24

CHAN 0 TX

X1.ring

X0.25

X2.tip

X0.13

X2.ring

X0.12

X3.tip

X0.11

X3.ring

X0.10

X4.tip

X0.9

X4.ring

X0.8

X5.tip

X0.7

X5.ring

X0.6

X6.tip

X0.5

X6.ring

X0.4

X7.tip

X0.3

X7.ring

X0.2

X8.tip

X0.14

X8.ring

X0.15

W2

W3

W4

W5

W6

W7

W8

CHAN 0 RX

CHAN 1 TX

CHAN 1 RX

CHAN 2 TX

CHAN 2 RX

CHAN 3 TX

CHAN 3 RX

Installation Positions
The installation positions of the 75-ohm E1 cable and 120-ohm cable in the BTS3012/
BTS3012AE are same, as shown in Table 5-17.
Table 5-17 Installation positions of the E1 cable

Issue 01 (2007-09-10)

Cable Type

BTS Type

One End (DB25 Male


Connector)

Other End (Bare Wire)

75-ohm/120ohm E1 cable

BTS3012

TR port on the DELC

Connects to a
transmission device such
as an internal transmission
interface box

BTS3012AE

TR port on the DELU

Connects to a
transmission device such
as an internal transmission
interface box

Huawei Technologies Proprietary

5-29

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5.4.2 Optical Cable of the BTS3012/BTS3012AE


This part describes the function, structure, pin assignment, and installation positions of the
optical cable of the BTS3012/BTS3012AE.

Functions
The optical cables are used to transmit optical signals between the cabinet and other devices.
The optical cable of the BTS3012/BTS3012AE uses the multi-mode fibers for short-distance
transmission.

Structure
Both ends of the multi-mode optical fiber are LC connectors. Figure 5-9 shows the structure of
the optical cable.
Figure 5-9 Structure of the optical cable

(1) Heat-shrink tube

(2) Tail wire

(3) LC connector

CAUTION
Apply a protective cap when the optical cable connector is not used.

Pin Assignment
None.

Installation Positions
Table 5-18 describes the installation positions of the optical cable.
5-30

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-18 Installation positions of the optical cable


Cable Type

One End

Other End (LC Connector)

Optical cable

Connects to the optical


transmission equipment, such as
Metro100

Connects to the transmission interface


box such as the ODF

5.4.3 Ethernet Cable of the BTS3012/BTS3012AE


This part describes the function, structure, pin assignment, and installation positions of the
Ethernet cables. There are two types of Ethernet cables: straight-through cable and crossover
cable.

Function
The Ethernet cables include the straight-through cable and crossover cable. They are used to
transmit maintenance signals.
l

The straight-through cable connects the PC where the site maintenance terminal system is
installed to the network.

The crossover cable directly connects the PC where the site maintenance terminal system
is installed to the BTS.

Structure
The crossover cable and straight-through cable use the same connector. However, they differ in
connector wiring. The Ethernet cable use RJ45 connectors on both ends, as shown in Figure
5-10.
Figure 5-10 Structure of the Ethernet cable
W

1
X1

X2

Pin Assignment
Table 5-19 describes the pin assignment for the Ethernet cable.
Table 5-19 Pin assignment for the Ethernet cable

Issue 01 (2007-09-10)

X1 End

Core Color

Core Type

X2 End of
the
StraightThrough
Cable

X2 End of the
Crossover
Cable

X1.2

Orange

Twisted pair

X2.2

X2.6

X1.1

White and orange

X2.1

X2.3

Huawei Technologies Proprietary

5-31

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

X1 End

Core Color

Core Type

X2 End of
the
StraightThrough
Cable

X2 End of the
Crossover
Cable

X1.6

Green

Twisted pair

X2.6

X2.2

X1.3

White and green

X2.3

X2.1

X1.4

Blue

X2.4

X2.4

X1.5

Blue and White

X2.5

X2.5

X1.8

Brown

X2.8

X2.8

X1.7

White and Brown

X2.7

X2.7

Twisted pair

Twisted pair

Installation Positions
The installation positions of the straight-through cable and crossover cable are same, as shown
in Table 5-20.
Table 5-20 Installation positions of the Ethernet cables
Type

One End

Other End

Straightthrough
cable

Connects to the MMI port on the


DTMU

Connects to the HUB or the LAN


switch port

Crossover
cable

Connects to the MMI port on the


DTMU

Connects to the network port of the PC


where the site maintenance terminal
system is installed
Connects to the network port of the
PC where the site maintenance
terminal system is installed

5.4.4 E1 Signal Transfer Cable for the BTS3012AE


The E1 signal transfer cable transfers four routes of E1 signals from the DSCB to the DCCU of
the cabinet.

Functions
The E1 signal transfer cable transfers four routes of E1 signals from the DSCB to the DCCU of
the cabinet.

Appearance
Figure 5-11 shows the structure of the E1 signal transfer cable.

5-32

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-11 Structure of the E1 signal transfer cable


View B
Pos.64
1
View A
Pos.1

Pos.1

B
Delander

X2

Pos.36

X1

(1) MD36 male connector

(2) MD64 male connector

Pin Assignment
Table 5-21 lists the pin assignment of the E1 signal transfer cable.
Table 5-21 Pin assignment of the E1 signal transfer cable

Issue 01 (2007-09-10)

Wire

Pin at the X1 End


(MD36 Male
Connector)

Pin at the X2 End


(MD64 Male
Connector)

Wire Type

X1.6

X2.11

Twisted pair

X1.7

X2.9

X1.24

X2.27

X1.25

X2.25

X1.8

X2.15

X1.9

X2.13

X1.26

X2.31

X1.27

X2.29

X1.2

X2.43

X1.3

X2.41

X1.20

X2.59

X1.21

X2.57

X1.4

X2.47

X1.5

X2.45

X1.22

X2. 63

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Huawei Technologies Proprietary

5-33

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Wire

Pin at the X1 End


(MD36 Male
Connector)

Pin at the X2 End


(MD64 Male
Connector)

X1.23

X2. 61

X1.14

X2.3

X1.15

X2.1

X1.32

X2.19

X1.33

X2.17

X1.16

X2.7

X1.17

X2.5

X1.34

X2.23

X1.35

X2.21

X1.10

X2.32

X1.11

X2.33

X1.28

X2.51

X1.29

X2.49

X1.12

X2.39

X1.13

X2.37

X1.30

X2.55

X1.31

X2.53

Shell

Shell

Wire Type

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Shield

Installation Positions
Table 5-22 shows the installation positions of the E1 signal transfer cable.
Table 5-22 Installation positions of the E1 signal transfer cable
Cable

One End (MD36 Male


Connector)

The Other End (MD64 Male


Connector)

E1 signal
transfer cable

Connects to port TO DCCU E1


on the DSCB

Connects to port TRAN on the DCCU

5.5 Signal Cables for the BTS3012AE


The signal cables for the BTS3012AE transmit the short-circuiting signals for the combiner on
the DTRU, signals between combined cabinets, signals between cabinet groups, power detection
signals, Boolean value input signals, signals between the DSCB and the DAFU, TOP1 signals
5-34

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

between the DCCU and the DSCB, TOP2 signals between the DCCU and the DSCB,
environment monitoring signals, RET control signals, monitoring transfer signals between the
NPMI and the DSCB, transfer signals between combined cabinets, PMU monitoring signals,
battery MCB alarm signals, AC lightning arrester alarm signals, humidity and temperature sensor
signals, door control sensor signals, smoke sensor signals, and water sensor signals.
5.5.1 Combining Short-Circuiting Signal Cable of the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the
combining short-circuiting signal cable.
5.5.2 Power Detection Cable of the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the power
detection cable.
5.5.3 Signal Cable for Combined Cabinets of the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions for the
signal cable for combined cabinets.
5.5.4 Signal Cable for Cabinet Groups of the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the signal
cable for cabinet groups.
5.5.5 Far Signal Cable Between BTS3012AE Cabinet Groups
The far signal cable between cabinet groups is used to transmit clock signals between cabinet
groups when the distance between the cabinet groups is 25 meters.
5.5.6 Boolean Input Cable of the BTS3012AE
The Boolean input cables are used to transmit control signals from the BTS3012AE to the other
devices so that the BTS3012AE can control the devices. The Boolean input cables of the
BTS3012AE can provide six Boolean signal outputs.
5.5.7 Signal Cables Between the DSCB and the DAFU Subrack in the BTS3012AE
The signal cables between the DSCB and the DAFU subrack transmit signals from the DSCB
to the DDPU/DFCU/DCOM in the DAFU subrack. There are two signal cables between the
DSCB and the DAFU subrack: one is from the DSCB to the modules in DAFU 0DAFU 2
subracks, and the other is from the DSCB to the modules in DAFU 3DAFU 5 subracks.
5.5.8 TOP1 Signal Cable Between the DCCU and the DSCB in the BTS3012AE
The TOP1 signal cable between the DCCU and the DSCB connects the DTMU and the DSCB.
The TOP1 signal cable transmits lightning protection signals collected by all the lightning
protection boards in the DSCB to the DTMU.
5.5.9 TOP2 Signal Cable Between the DCSU and the DSCB in the BTS3012AE
The TOP2 signal cable between the DCSU and the DSCB connects the DCSU and the DSCB.
The TOP2 signal cable transmits lightning protection signals collected by all the lightning
protection boards in the DSCB to the DCSU.
5.5.10 Signal Cable Between the DCSU and the DTRB in the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the signal
cable between the DCSU and the DTRB.
5.5.11 Signal Transfer Cable Between BTS3012AE Combined Cabinets
The signal transfer cable between combined cabinets connects the common subrack and the
signal lightning protection subrack. The cable transmits the Boolean value alarm signals from
the signal lightning protection subrack to the common subrack.
5.5.12 RS485 Environment Monitoring Signal Cable for the BTS3012AE
Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-35

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

The RS485 environment monitoring signal cable transfers the RS485 monitoring signals in the
BTS3012AE cabinet. The RS485 environment monitoring signal cable transfers the
environment monitoring signals to the DCCU. The environment monitoring signals are collected
from the PMU, fan subrack, fan filter unit, and sensors.
5.5.13 RET Control Signal Cable of the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the RET
control signal cable.
5.5.14 Monitoring Transfer Signal Cable Between the NPMI and the DSCB in the BTS3012AE
The monitoring transfer signal cable between the NPMI and the DSCB connects the NPMI and
the DSCB. The cable transmits the alarm information collected by the NPMI to the DSCB.
5.5.15 Diversity Receive Short-Circuiting Cable of the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the
diversity receive short-circuiting cable.
5.5.16 Four-In-One Short-Circuiting Cable of the BTS3012/BTS3012AE
This cable describes the function, structure, pin assignment, and installation positions of the
four-in-one short-circuiting cable.
5.5.17 Signal Cable Between the DFCB and the DFCU in the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the signal
cable between the DFCB and the DFCU.
5.5.18 DPMU Monitoring Cable for the BTS3012AE
The DPMU monitoring cable connects the NPMI and the DPMU. It transmits the sensor signals
collected by the NPMI to the DPMU.
5.5.19 Alarm Cable for the MCB of the BTS3012AE Battery
The alarm cable for the MCB of the BTS3012AE battery connects the battery and the NPMI. It
transmits the voltage information about the battery to the NPMI.
5.5.20 Alarm Cable for the BTS3012AE Lightning Arrester
The alarm cable for the lightning arrester connects the AC lightning arrester and the NPMI. It
transmits the information about the lightning arrester to the NPMI.
5.5.21 Signal Cable for the Humidity and Temperature Sensor of the BTS3012AE
The signal cable for the humidity and temperature sensor connects the humidity and temperature
sensor and the NPMI. It transmits the information about the humidity and temperature of the
battery cabin from the humidity and temperature sensor to the NPMI.
5.5.22 Signal Cable for the Door Control Sensor of the BTS3012AE
The signal cable for the door control sensor connects the door control sensor and the NPMI. It
transmits the open and close information about the door from the door control sensor to the
NPMI.
5.5.23 Signal Cable for the Smoke Sensor of the BTS3012AE
The signal cable for the smoke sensor connects the smoke sensor and the NPMI. It transmits the
smoke information collected by the smoke sensor to the NPMI.
5.5.24 Cable for the Water Sensor of the BTS3012AE
The signal cable for the water sensor connects the water sensor and the NPMI. It transmits the
water information collected by the water sensor to the NPMI.

5-36

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5.5.1 Combining Short-Circuiting Signal Cable of the BTS3012/


BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the
combining short-circuiting signal cable.

Function
This cable is used to achieve the combination output of RF signals by connecting the TX port
with the IN port on the DTRU (type A).

Structure
Figure 5-12 shows the structure of the combining short-circuiting signal cable.
Figure 5-12 Structure of the combining short-circuiting signal cable
W
3
1
2

(1) N male connector

(2) SMA male connector

(3) Label

Pin Assignment
None.

Installation Positions
Table 5-23 describes the installation positions of the combining short-circuiting signal cable.
Table 5-23 Installation positions of the combining short-circuiting signal cable
Cable Type

One End (N Type)

Combining shortcircuiting signal


cable

Connects to the TX1 port


on the DTRU (type A)
panel
Connects to the TX2 port
on the DTRU (type A)
panel

Other End (SMA Type)


l

Connects to the IN1 port on the


DTRU (type A) panel

Connects to the IN2 port on the


DTRU (type A) panel

5.5.2 Power Detection Cable of the BTS3012/BTS3012AE


This part describes the function, structure, pin assignment, and installation positions of the power
detection cable.
Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-37

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Function
The power detection cable transmits the RF signal sent from the coupling unit in the DFCU/
DFCB to the power detection unit. This cable can be categorized into forward power detection
cable and reverse power detection cable. The forward power detection cable has the same
structure as the reverse power detection cable.

Structure
Figure 5-13 shows the structure of the power detection cable.
Figure 5-13 Structure of the power detection cable
1

1
RF Rx Cable

(1) SMA elbow male connector

Pin Assignment
None.

Installation Positions
Table 5-24 describes the installation positions of the power detection cable.
Table 5-24 Installation positions of the power detection cable
Cable

One End

Other End

Forward power
detection cable

Connects to the PF in port on the


DFCU/DFCB panel

Connects to the PF out port on the


DFCU/DFCB panel

Reverse power
detection cable

Connects to the PR in port on the


DFCU/DFCB panel

Connects to the PR out port on the


DFCU/DFCB panel

5.5.3 Signal Cable for Combined Cabinets of the BTS3012/


BTS3012AE
This part describes the function, structure, pin assignment, and installation positions for the
signal cable for combined cabinets.

Function
The signal cable for combined cabinets is used to transmit the signals between two combined
cabinets.

Structure
Figure 5-14 shows the structure of the signal cable for combined cabinets.
5-38

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-14 Structure of the signal cable for combined cabinets

(1) MD68 male connector

(2) MD68 male connector

Pin Assignment
Table 5-25 describes the pin assignment for the signal cable for combined cabinets.
Table 5-25 Pins assignment for the signal cable for combined cabinets

Issue 01 (2007-09-10)

Pin at the X1 End

Pin at the X2 End

Core Type

X1.2

X2.2

Twisted pair

X1.3

X2.3

X1.4

X2.4

X1.5

X2.5

X1.7

X2.7

X1.8

X2.8

X1.9

X2.9

X1.10

X2.10

X1.36

X2.36

X1.37

X2.37

X1.38

X2.38

X1.39

X2.39

X1.41

X2.41

X1.42

X2.42
Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

5-39

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5-40

Pin at the X1 End

Pin at the X2 End

Core Type

X1.43

X2.43

Twisted pair

X1.44

X2.44

X1.46

X2.46

X1.47

X2.47

X1.48

X2.48

X1.49

X2.49

X1.22

X2.22

X1.23

X2.23

X1.25

X2.25

X1.26

X2.26

X1.51

X2.51

X1.52

X2.52

X1.53

X2.53

X1.54

X2.54

X1.28

X2.28

X1.29

X2.29

X1.30

X2.30

X1.31

X2.31

X1.56

X2.56

X1.57

X2.57

X1.59

X2.59

X1.60

X2.60

X1.12

X2.12

X1.13

X2.13

X1.14

X2.14

X1.15

X2.15

X1.62

X2.62

X1.63

X2.63

X1.64

X2.64

X1.65

X2.65

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Pin at the X1 End

Pin at the X2 End

Core Type

X1.17

X2.17

Twisted pair

X1.18

X2.18

X1.19

X2.19

X1.20

X2.20

Twisted pair

Installation Positions
Table 5-26 describes the installation positions of the signal cable for combined cabinets.
Table 5-26 Installation positions of the signal cable for combined cabinets
Cabinet Type

One End (MD68 Male


Connector)

Other End (MD68 Male Connector)

BTS3012

Connects to the DCF port on


the DCTB of one cabinet

Connects to the DCF port on the DCTB


of the other cabinet

BTS3012AE

Connects to the TO SLAVE


CABINET port on the DSCB
of one cabinet

Connects to the TO SLAVE CABINET


port on the DSCB of the other cabinet

5.5.4 Signal Cable for Cabinet Groups of the BTS3012/BTS3012AE


This part describes the function, structure, pin assignment, and installation positions of the signal
cable for cabinet groups.

Function
The signal cable for cabinet groups is used to transmit signals between the cabinet groups.

Structure
Figure 5-15 shows the structure of the signal cable for cabinet groups.
Figure 5-15 Structure of the signal cable for cabinet groups
Pos.1

Pos.36

X1

(1) MD36 male connector

Issue 01 (2007-09-10)

X2

(2) MD36 male connector

Huawei Technologies Proprietary

5-41

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Pin Assignment
Table 5-27 describes the pin assignment for the signal cable for cabinet groups.
Table 5-27 Pin assignment for the signal cable for cabinet groups

5-42

Pin at the X1 End

Pin at the X2 End

Wire Type

X1.1

X2.1

Twisted pair

X1.19

X2.19

X1.20

X2.2

X1.21

X2.3

X1.22

X2.4

X1.23

X2.5

X1.24

X2.6

X1.25

X2.7

X1.26

X2.8

X1.27

X2.9

X1.29

X2.11

X1.30

X2.12

X1.31

X2.13

X1.32

X2.14

X1.33

X2.15

X1.34

X2.16

X1.35

X2.17

X1.36

X2.18

X1.2

X2.20

X1.3

X2.21

X1.4

X2.22

X1.5

X2.23

X1.6

X2.24

X1.7

X2.25

X1.8

X2.26

X1.9

X2.27

X1.11

X2.29
Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair
Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Pin at the X1 End

Pin at the X2 End

X1.12

X2.30

X1.13

X2.31

X1.14

X2.32

X1.15

X2.33

X1.16

X2.34

X1.17

X2.35

X1.18

X2.36

Wire Type

Twisted pair

Twisted pair

Twisted pair

Installation Positions
Table 5-28 describes the installation positions of the signal cable for cabinet groups.
Table 5-28 Installation positions of the signal cable for cabinet groups
Cable Type

BTS Type

One End (MD36 Male


Connector)

Other End (MD36 Male


Connector)

Signal cable
for cabinet
groups

BTS3012

Connects to the CKB1 or


CKB2 port on top of one
main cabinet in the cabinet
group

Connects to the CKB1 or


CKB2 port on top of the
other main cabinet in the
cabinet group

BTS3012AE

Connects to the TO
SLAVE GROUP1 or TO
SLAVE GROUP2 port on
the DSCB of one main
cabinet in the cabinet group

Connects to the TO SLAVE


GROUP1 or TO SLAVE
GROUP2 port on the DSCB
of the other main cabinet in
the cabinet group

5.5.5 Far Signal Cable Between BTS3012AE Cabinet Groups


The far signal cable between cabinet groups is used to transmit clock signals between cabinet
groups when the distance between the cabinet groups is 25 meters.

Functions
The far signal cable between cabinet groups is used to transmit clock signals between cabinet
groups when the distance between the cabinet groups is 25 meters.

Appearance
Figure 5-16 shows the structure of the far signal cable between cabinet groups.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-43

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-16 Far signal cable between cabinet groups


1

Pos.1

Pos.25

X1

X2

(1) DB25 male connector

(2) DB25 male connector

Pin Assignment
Table 5-29 lists the pin assignment for the signal cable between cabinet groups.
Table 5-29 Pins assignment for the signal cable between cabinet groups

5-44

Pin of the X1 End (DB25


Connector)

Pin of the X2 End (DB25


Connector)

Wire Type

X1.1

X2.1

Twisted pair

X1.16

X2.16

X1.2

X2.2

X1.3

X2.3

X1.4

X2.4

X1.5

X2.5

X1.6

X2.6

X1.7

X2.7

X1.8

X2.8

X1.9

X2.9

X1.10

X2.10

X1.11

X2.11

X1.12

X2.12

X1.13

X2.13

X1.14

X2.14

X1.14

X2.15

X1.24

X2.24

X1.25

X2.25
Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Pin of the X1 End (DB25


Connector)

Pin of the X2 End (DB25


Connector)

Wire Type

Shell

Shell

Shield

Installation Positions
Table 5-30 describes the installation positions of the far signal cable between cabinet groups.
Table 5-30 Installation positions of far signal cable between cabinet groups
Signal Cable

One End (DB25 Male


Connector)

The Other End (DB25 Male


Connector)

Far signal cable between


cabinet groups

Connects to the CKB port on


the DGLU in the main cabinet
group

Connects to the CKB port on the


DGLU in the extension cabinet
group

5.5.6 Boolean Input Cable of the BTS3012AE


The Boolean input cables are used to transmit control signals from the BTS3012AE to the other
devices so that the BTS3012AE can control the devices. The Boolean input cables of the
BTS3012AE can provide six Boolean signal outputs.

Function
The Boolean input cables are used to transmit control signals from the BTS3012AE to the other
devices so that the BTS3012AE can control the devices.

Appearance
One end of the cable is a DB44 male connector, and the other end is bare. Figure 5-17 shows
the Boolean input cable
.
Figure 5-17 Boolean input cable
1
View A POS.1

X1
W

POS.44

(1) DB44 male connector

Issue 01 (2007-09-10)

(2) Bare wire

Huawei Technologies Proprietary

5-45

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Pin Description
Table 5-31 lists the pin assignment of the Boolean value input cable.
Table 5-31 Pin assignment of the Boolean input cable
Pin of the
Connector

Wire Type

Wire Color

Alarm Input
Serial Number

X1.1

Twisted pair

Blue

Alarm input 6
(provided by the
DTMU)

X1.17
X1.2

White
Twisted pair

X1.18
X1.3

White
Twisted pair

X1.19
X1.4

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Blue
Black

Twisted pair

X1.27

5-46

Grey
Red

X1.26
X1.12

Brown
Red

X1.25
X1.11

Green
Red

X1.24
X1.10

Orange
Red

X1.38
X1.9

Blue
Red

X1.23
X1.8

Grey
White

X1.22
X1.7

Brown
White

X1.21
X1.6

Green
White

X1.20
X1.5

Orange

Orange
Black

Huawei Technologies Proprietary

Alarm input 2
(provided by the
DTMU)
Alarm input 1
(provided by the
DTMU)
Alarm input 4
(provided by the
DTMU)
Alarm input 3
(provided by the
DTMU)
Alarm input 5
(provided by the
DTMU)
Alarm input 7
(provided by the
DTMU)
Alarm input 1
(provided by the
NPMI)
Alarm input 8
(provided by the
DTMU)
Alarm input 2
(provided by the
NPMI)
Alarm input 5
(provided by the
NPMI)
Alarm input 4
(provided by the
NPMI)

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Pin of the
Connector

Wire Type

Wire Color

Alarm Input
Serial Number

X1.13

Twisted pair

Green

Alarm input 6
(provided by the
NPMI)

X1.28
X1.14

Black
Twisted pair

X1.29
X1.34

Twisted pair

X1.35
X1.36

Black

Alarm input 7
(provided by the
NPMI)

Grey

Black
Twisted pair

X1.37
Shell

Brown

Blue

Yellow
Shield

Installation Positions
Table 5-32 describes the installation positions of the Boolean value input cable.
Table 5-32 Installation positions of the Boolean input cable
Signal Cable

One End (DB44 Male


Connector)

The Other End (Bare Wire)

Boolean input
cable

Connects to port SW IN/OUT


on the DMLU

The two wires at the bare end connect


to the relevant control device.

5.5.7 Signal Cables Between the DSCB and the DAFU Subrack in
the BTS3012AE
The signal cables between the DSCB and the DAFU subrack transmit signals from the DSCB
to the DDPU/DFCU/DCOM in the DAFU subrack. There are two signal cables between the
DSCB and the DAFU subrack: one is from the DSCB to the modules in DAFU 0DAFU 2
subracks, and the other is from the DSCB to the modules in DAFU 3DAFU 5 subracks.

Functions
The signal cables between the DSCB and the DAFU subrack transmit signals from the DSCB
to the DDPU/DFCU/DCOM in the DAFU subrack.

Appearance
The two signal cables between the DSCB and the DAFU subrack have the same appearance and
structure. Figure 5-18 shows the signal cable.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-47

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-18 Signal cable between the DSCB and the DAFU subrack
1

B
2

W1

W2

W3
View A
Pos.1

X2

X3

View B
Pos.26

X4

Pos.1

Pos.68

(1) MD68 male connector

(2) DB26 male connector

Pin Assignment
The pins of the two cables between the DSCB and the DAFU subrack are the same. Table
5-33 lists the pin assignment for one signal cable between the DSCB and the DAFU subrack.
Table 5-33 Pins assignment for the signal cable between the DSCB and the DAFU subrack

5-48

Signal
Cable

Pin of the MD68


Connector at the X1
End

Pin of the X2 End (DB26


Connector)

Wire Type

W1

X1.1

X2.7

Twisted pair

X1.2

X2.8

X1.3

X2.11

X1.4

X2.10

X1.35

X2.20

X1.36

X2.19

X1.37

X2.13

X1.38

X2.12

X1.5

X2.16

X1.6

X2.9

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Signal
Cable

W2

W3

Issue 01 (2007-09-10)

5 BTS3012AE Cables

Pin of the MD68


Connector at the X1
End

Pin of the X2 End (DB26


Connector)

Wire Type

X1.7

X2.17

Twisted pair

X1.8

X2.18

X1.39

X2.15

X1.40

X2.26

X1.41

X2.24

X1.42

X2.25

X1.13

X3.7

X1.14

X3.8

X1.15

X3.11

X1.16

X3.10

X1.47

X3.20

X1.48

X3.19

X1.49

X3.13

X1.50

X3.12

X1.17

X3.9

X1.18

X3.16

X1.19

X3.17

X1.20

X3.18

X1.51

X3.15

X1.52

X3.24

X1.53

X3.26

X1.54

X3.25

X1.25

X4.7

X1.26

X4.8

X1.27

X4.11

X1.28

X4.10

X1.59

X4.20

X1.60

X4.19

X1.61

X4.13

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

5-49

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Signal
Cable

Pin of the MD68


Connector at the X1
End

Pin of the X2 End (DB26


Connector)

X1.62

X4.12

X1.29

X4.9

X1.30

X4.17

X1.31

X4.16

X1.32

X4.18

X1.63

X4.15

X1.64

X4.26

X1.65

X4.24

X1.66

X4.25

Wire Type

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Installation Positions
Table 5-34 lists the installation positions of the two signal cables between the DSCB and the
DAFU subrack.
Table 5-34 Installation positions of the signal cables between the DSCB and the DAFU subrack
Signal Cable

One End (MD68


Male
Connector)

The Other End (Three DB26 Male


Connectors)

Signal cable
between the
DSCB and
DAFU0DAFU2
in the DAFU
subrack

Connects to port
TO DAFU 0-2 on
the DSCB

Connects to the COM/DBUS/ONSHELL port on


the DDPU/DFCU/DCOM panel in subrack
DAFU0
Connects to the COM/DBUS/ONSHELL port on
the DDPU/DFCU/DCOM panel in subrack
DAFU1
Connects to the COM/DBUS/ONSHELL port on
the DDPU/DFCU/DCOM panel in subrack
DAFU2

Signal cable
between the
DSCB and
DAFU3DAFU5
in the DAFU
subrack

Connects to port
TO DAFU 3-5 on
the DSCB

Connects to the COM/DBUS/ONSHELL port on


the DDPU/DFCU/DCOM panel in subrack
DAFU3
Connects to the COM/DFCU/ONSHELL port on
the DDPU/DFCU/DCOM panel in subrack
DAFU4
Connects to the COM/DBUS/ONSHELL port on
the DDPU/DFCU/DCOM panel in subrack
DAFU5

5-50

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5.5.8 TOP1 Signal Cable Between the DCCU and the DSCB in the
BTS3012AE
The TOP1 signal cable between the DCCU and the DSCB connects the DTMU and the DSCB.
The TOP1 signal cable transmits lightning protection signals collected by all the lightning
protection boards in the DSCB to the DTMU.

Functions
The TOP1 signal cable between the DCCU and the DSCB connects the DTMU and the DSCB.
The TOP1 signal cable transmits lightning protection signals collected by all the lightning
protection boards in the DSCB to the DTMU.

Appearance
Figure 5-19 shows the TOP1 signal cable between the DCCU and the DSCB.
Figure 5-19 TOP1 signal cable between the DCCU and the DSCB
View B
Pos.64
2

View A
Pos.1

Pos.1

Delander

X2

Pos.68

X1

(1) MD68 male connector

(2) MD64 male connector

Pin Assignment
Table 5-35 lists the pin assignment of the TOP1 signal cable between the DCCU and the DSCB.
Table 5-35 Pin assignment of the TOP1 signal cable between the DCCU and the DSCB

Issue 01 (2007-09-10)

Signal Cable

Pin of the MD68


Connector at the X1
End

Pin of the X2 End


(MD64 Connector)

Wire Type

X1.5

X2.35

Twisted pair

X1.6

X2.36

X1.7

X2.37
Huawei Technologies Proprietary

Twisted pair
5-51

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Signal Cable

5-52

Pin of the MD68


Connector at the X1
End

Pin of the X2 End


(MD64 Connector)

X1.8

X2.38

X1.9

X2.11

X1.10

X2.12

X1.11

X2.15

X1.12

X2.16

X1.13

X2.3

X1.14

X2.4

X1.15

X2. 7

X1.16

X2.8

X1.17

X2.13

X1.18

X2.14

X1.19

X2.30

X1.20

X2.29

X1.21

X2.5

X1.22

X2.6

X1.23

X2.9

X1.24

X2.10

X1.25

X2.23

X1.26

X2.24

X1.27

X2.27

X1.28

X2.28

X1.29

X2.19

X1.30

X2.20

X1.31

X2.21

X1.32

X2.22

X1.33

X2.56

X1.66

X2.55

X1.38

X2.58

X1.39

X2.57

Huawei Technologies Proprietary

Wire Type

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Signal Cable

Issue 01 (2007-09-10)

5 BTS3012AE Cables

Pin of the MD68


Connector at the X1
End

Pin of the X2 End


(MD64 Connector)

Wire Type

X1.40

X2.60

Twisted pair

X1.41

X2.59

X1.42

X2.54

X1.43

X2.53

X1.44

X2.49

X1.45

X2.50

X1.46

X2.44

X1.47

X2.43

X1.48

X2.64

X1.49

X2.63

X1.50

X2.52

X1.51

X2.51

X1.52

X2.33

X1.53

X2.34

X1.54

X2.32

X1.55

X2.31

X1.56

X2.48

X1.57

X2.47

X1.58

X2.17

X1.59

X2.18

X1.60

X2.1

X1.61

X2.2

X1.62

X2.46

X1.63

X2.45

X1.64

X2.62

X1.65

X2.61

X1.2

X2.25

X1.3

X2.40

X1.4

X2.39

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

5-53

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Signal Cable

W.Shield

Pin of the MD68


Connector at the X1
End

Pin of the X2 End


(MD64 Connector)

Wire Type

X1.36

X2.26

X1.37

X2.41

X1.1

Shield

X1.34

X1.35

X1.68

X1.Shell

X2.42

X2.Shell

Installation Positions
Table 5-36 lists the installation positions of the TOP1 signal cable between the DCCU and the
DSCB.
Table 5-36 Installation positions of the TOP1 signal cable between the DCCU and the DSCB
Signal Cable

One End (MD68 Male


Connector)

The Other End (MD64 Male


Connector)

TOP1 signal cable


between the DCCU and
the DSCB

Connects to the port TOP


(FROM DCCU) on the
DSCB

Connects to the port TO_TOP1 on


the DCCU

5.5.9 TOP2 Signal Cable Between the DCSU and the DSCB in the
BTS3012AE
The TOP2 signal cable between the DCSU and the DSCB connects the DCSU and the DSCB.
The TOP2 signal cable transmits lightning protection signals collected by all the lightning
protection boards in the DSCB to the DCSU.

Functions
The TOP2 signal cable between the DCSU and the DSCB connects the DCSU and the DSCB.
The TOP2 signal cable transmits lightning protection signals collected by all the lightning
protection boards in the DSCB to the DCSU.

Appearance
Figure 5-20 shows the TOP2 signal cable between the DCSU and the DSCB.
5-54

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-20 TOP2 signal cable between the DCSU and the DSCB
View A
Pos.1

2
W

A
Pos.26

View B
Pos.1
B

X1

X3

(1) DB26 male connector

Pos.36

(2) MD36 male connector

Pin Assignment
Table 5-37 lists the pin assignment of the TOP2 signal cable between the DCSU and the DSCB.
Table 5-37 Pin assignment of the TOP2 signal cable between the DCSU and the DSCB
Wire

Pin of the DB26


Connector at the X1
End

Pin of the X2 End


(MD36 Connector)

Wire Type

X1.16

X2.6

X1.12

X2.7

X1.11

X2.8

X1.10

X2.9

X1.8

X2.10

Twisted pair

X1.9

X2.28

X1.3

X2.11

X1.1

X2.12

X1.17

X2.24

X1.15

X2.25

X1.14

X2.26

X1.13

X2.27

X1.2

X2.29

X1.4

X2.14

Shield

X1.7

X2.21

X1.Shell

X2.Shell

Installation Positions
Table 5-38 lists the installation positions of the TOP2 signal cable between the DCSU and the
DSCB.
Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-55

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-38 Installation positions of the TOP2 signal cable between the DCSU and the DSCB
Signal Cable

One End (DB26 Male


Connector)

The Other End (MD36 Male


Connector)

TOP2 signal cable


between the DCSU and
the DSCB

Connects to the port TOP2


on the DCSU

Connects to the port TO DCSU


TOP on the DSCB

5.5.10 Signal Cable Between the DCSU and the DTRB in the
BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the signal
cable between the DCSU and the DTRB.

Function
The signal cable between the DCSU and the DTRB is used to transmit signals between the DTRU
and the DCSU. The signals include the data bus signals, clock bus signals, CBUS2 signals, and
in-position signals.

Structure
Figure 5-21 shows the structure of the signal cable between the DCSU and the DTRB.
Figure 5-21 Structure of the signal cable between the DCSU and the DTRB
Pos.1

View A

View B

Pos.68
Pos.64
A

Pos.1
B

Delander

W
X1

X2

(1) MD64 male connector

(2) MD68 male connector

Pin Assignment
Table 5-39 describes the pin assignment for the signal cable between the DCSU and the DTRB.

5-56

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-39 Pin assignment for the signal cable between the DCSU and the DTRB

Issue 01 (2007-09-10)

Cable

Pin of the MD64


Connector at the X1
End

Pin of the MD68


Connector at the
X2 End

Wire Type

X1.1

X2.1

Twisted pair

X1.2

X2.2

X1.3

X2.35

X1.4

X2.36

X1.5

X2.3

X1.6

X2.46

X1.7

X2.4

X1.8

X2.5

X1.9

X2.38

X1.10

X2.39

X1.11

X2.6

X1.12

X2.40

X1.13

X2.7

X1.14

X2.8

X1.15

X2.41

X1.16

X2.42

X1.17

X2.10

X1.18

X2.11

X1.19

X2.44

X1.20

X2.45

X1.21

X2.21

X1.22

X2.26

X1.23

X2.13

X1.24

X2.14

X1.25

X2.47

X1.26

X2.48

X1.27

X2.55

X1.28

X2.60

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

5-57

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Cable

5-58

Pin of the MD64


Connector at the X1
End

Pin of the MD68


Connector at the
X2 End

Wire Type

X1.29

X2.16

Twisted pair

X1.30

X2.17

X1.31

X2.50

X1.32

X2.51

X1.33

X2.19

X1.34

X2.20

X1.35

X2.53

X1.36

X2.54

X1.37

X2.18

X1.38

X2.52

X1.39

X2.22

X1.40

X2.23

X1.41

X2.25

X1.42

X2.59

X1.43

X2.37

X1.44

X2.49

X1.45

X2.27

X1.46

X2.28

X1.47

X2.61

X1.48

X2.62

X1.49

X2.30

X1.50

X2.31

X1.51

X2.64

X1.52

X2.65

X1.55

X2.58

X1.56

X2.56

X1.57

X2.24

X1.58

X2.57

X1.59

X2.32

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Cable

5 BTS3012AE Cables

Pin of the MD64


Connector at the X1
End

Pin of the MD68


Connector at the
X2 End

X1.60

X2.66

X1.61

X2.33

X1.62

X2.34

X1.63

X2.67

X1.64

X2.68

X1.53

X2.63

Wire Type

Twisted pair

Twisted pair

Twisted pair

Installation Positions
Table 5-40 describes the installation positions of the signal cable between the DCSU and the
DTRB.
Table 5-40 Installation positions of the signal cable between the DCSU and the DTRB
Cable

One End (MD64 Male


Connector)

Other End (MD68 Male Connector)

Signal cable
between the
DCSU and the
DTRB

Connects to the TO_DTRB


port on the DCSU panel

Connects to the MD68 port on the DTRB

5.5.11 Signal Transfer Cable Between BTS3012AE Combined


Cabinets
The signal transfer cable between combined cabinets connects the common subrack and the
signal lightning protection subrack. The cable transmits the Boolean value alarm signals from
the signal lightning protection subrack to the common subrack.

Functions
The signal transfer cable between combined cabinets connects the common subrack and the
signal lightning protection subrack. The cable transmits the Boolean value alarm signals from
the signal lightning protection subrack to the common subrack.

Appearance
Figure 5-22 shows the signal transfer cable between combined cabinets.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-59

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-22 Signal transfer cable between BTS3012AE combined cabinets


View B
Pos.64
2

View A
Pos.1

Pos.1

Delander

X2

Pos.68

X1

(1) MD68 male connector

(2) MD64 male connector

Pin Assignment
Table 5-41 lists the pin assignment of the signal transfer cable between combined cabinets.
Table 5-41 Pin assignment of the signal transfer cable between combined cabinets

5-60

Wire

Pin of the MD68


Connector at the
X1 End

Pin of the X2 End (MD64


Connector)

Wire Type

X1.13

X2.32

Twisted pair

X1.14

X2.31

X1.15

X2.30

X1.16

X2.29

X1.17

X2.16

X1.18

X2.15

X1.19

X2.14

X1.20

X2.13

X1.21

X2.40

X1.22

X2.39

X1.23

X2. 36

X1.24

X2.35

X1.25

X2.34

X1.26

X2.33

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Wire

Issue 01 (2007-09-10)

5 BTS3012AE Cables

Pin of the MD68


Connector at the
X1 End

Pin of the X2 End (MD64


Connector)

Wire Type

X1.27

X2.58

Twisted pair

X1.28

X2.57

X1.29

X2.56

X1.30

X2.55

X1.31

X2.4

X1.32

X2.3

X1.33

X2.2

X1.34

X2.1

X1.45

X2.52

X1.46

X2.51

X1.47

X2.50

X1.48

X2.49

X1.49

X2.64

X1.50

X2.63

X1.51

X2.62

X1.52

X2.61

X1.53

X2.48

X1.54

X2.47

X1.55

X2.46

X1.56

X2.45

X1.57

X2.26

X1.58

X2.25

X1.59

X2.24

X1.60

X2.23

X1.61

X2.20

X1.62

X2.19

X1.63

X2.18

X1.64

X2.17

X1.65

X2.10

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

5-61

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Wire

Pin of the MD68


Connector at the
X1 End

Pin of the X2 End (MD64


Connector)

Wire Type

X1.66

X2.9

X1.67

X2.8

X1.68

X2.7

X1.6

X2.5

X1.7

X2.6

X1.8

X2.11

X1.9

X2.12

X1.5

X2.21

Shield

X1.10

X2.22

X1.39

X2.27

X1.40

X2.28

X1.41

X2.59

X1.44

X2.60

X1.Shell

X2.Shell

Twisted pair

Installation Positions
Table 5-42 lists the installation positions of the signal transfer cable between combined cabinets.
Table 5-42 Installation positions of the signal transfer cable between combined cabinets
Signal Cable

One End (MD68 Male


Connector)

The Other End (MD64 Male


Connector)

Signal transfer
cable between
BTS3012AE
combined
cabinets

Connects to the port TO SLAVE


MASTER (FROM DCSU) on the
DSCB

Connects to the port CC_IN on the


DCSU in one single cabinet or
cabinet groups
Connects to the port CC_OUT on
the DCSU of the main cabinet and
to the port CC_IN on the DCSU of
the extension cabinet when the
combined cabinets are used

5.5.12 RS485 Environment Monitoring Signal Cable for the


BTS3012AE
The RS485 environment monitoring signal cable transfers the RS485 monitoring signals in the
BTS3012AE cabinet. The RS485 environment monitoring signal cable transfers the
5-62

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

environment monitoring signals to the DCCU. The environment monitoring signals are collected
from the PMU, fan subrack, fan filter unit, and sensors.

Function
The RS485 environment monitoring signal cable transfers the RS485 monitoring signals in the
BTS3012AE cabinet. The RS485 environment monitoring signal cable transfers the
environment monitoring signals to the DCCU. The environment monitoring signals are collected
from the PMU, fan subrack, fan filter unit, and sensors.

Appearance
Figure 5-23 shows the RS485 environment monitoring signal cable.
Figure 5-23 RS485 environment monitoring signal cable
View B

2
W1

B
1

X2
View A
Pos.1

W2

A
X1

Pos.26

X3
4

View E
1
2
3
4
5

View C
3
Pos.1

W3

Pos.15
View D
Pos.1
D

W4

X5

X4
Pos.26

(1) DB26 male connector

(2) RJ45 connector

(4) DB26 male connector

(5) Common 5-pin connector

(3) DB15 female connector

Pin Assignment
Table 5-43 lists the pin assignment of W1 shown in Figure 5-23.
Table 5-43 Pin assignment of W1

Issue 01 (2007-09-10)

Wire

Pin of the DB26


Connector at the X1
End

Pin of the X2 End


(RJ45 Connector)

Wire Type

W1

X1.19

X2.1

Twisted pair

X1.11

X2.2

X1.1

X2.4

X1.10

X2.5
Huawei Technologies Proprietary

Twisted pair

5-63

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Wire

Pin of the DB26


Connector at the X1
End

Pin of the X2 End


(RJ45 Connector)

Wire Type

X1.Shell

X2.Shell

Shield

Table 5-44 lists the pin assignment of W2 shown in Figure 5-23.


Table 5-44 Pin assignment of W2
Wire

Pin of the DB26


Connector at the X1
End

Pin of the X3 End


(DB15 Connector)

Description

W2

X1.19

X3.1

Twisted pair

X1.11

X3.2

X1.1

X3.4

X1.10

X3.5

X1.Shell

X3.Shell

Twisted pair

Shield

Table 5-45 lists the pin assignment of W3 shown in Figure 5-23.


Table 5-45 Pin assignment of W3

5-64

Wire

Pin of the DB26


Connector at the X1
End

Pin of the X4 End


(DB26 Connector)

Description

W3

X1.1

X4.1

Twisted pair

X1.10

X4.10

X1.2

X4.2

X1.3

X4.3

X1.4

X4.4

X1.5

X4.5

X1.6

X4.6

X1.7

X4.7

X1.11

X4.11

X1.19

X4.19

X1.13

X4.13

X1.14

X4.14

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Wire

Pin of the DB26


Connector at the X1
End

Pin of the X4 End


(DB26 Connector)

Description

X1.12

X4.12

Twisted pair

X1.16

X4.16

X1.17

X4.17

X1.12

X4.12

X1.20

X4.20

X1.21

X4.21

X1.22

X4.22

X1.23

X4.23

X1.24

X4.24

X1.25

X4.25

X1.Shell

X4.Shell

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Shield

Table 5-46 lists the pin assignment of W4 shown in Figure 5-23.


Table 5-46 Pin assignment of W4
Wire

Pin of the X4
End (DB26
Connector)

Pin of the X5
End (Common
5-Pin
Connector)

Description

Wire Color

W4

X4.8

X5.1

Twisted pair

Black

X4.9

X5.2

X4.18

X5.3

X4.Shell

Shield

Installation Positions
Table 5-47 lists the installation positions of the RS485 environment monitoring signal cable.
Table 5-47 Installation positions of the RS485 environment monitoring signal cable

Issue 01 (2007-09-10)

Signal Cable

One End (DB26 Male


Connector)

The Other End

RS485
environment

Connects to the port


To_FAN on the DCCU

The RJ45 connector connects to port


RS232/RS422 on the DPMU.

Huawei Technologies Proprietary

5-65

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Signal Cable

One End (DB26 Male


Connector)

The Other End

monitoring signal
cable

The DB15 female connector connects to


the COM port on the fan filter unit on the
front door.
The DB26 male connector connects to
port COM on the FAN Box.
The common 5-pin connector connects to
the sensor on the left of the air inlet.

5.5.13 RET Control Signal Cable of the BTS3012/BTS3012AE


This part describes the function, structure, pin assignment, and installation positions of the RET
control signal cable.

Function
The RET control signal cable is used to transmit signals between the DATU and the Bias-Tee.

Structure
Figure 5-24 shows the structure of the RET control signal cable.
Figure 5-24 Structure of the RET control signal cable
2

1
W
X1

X2

(1) SMA male connector

(2) SMA elbow male connector

Pin Description
None

Installation Positions
Table 5-48 describes the installation positions of the RET control signal cable.

5-66

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-48 Installation positions of the RET control signal cable


Cable Type

One End (SMA Male


Connector)

Other End (SMA Elbow Male


Connector)

RET control
signal cable

Connects to the SMA port on the


Bias-Tee

Connects to any ANT port on the


DATU panel

5.5.14 Monitoring Transfer Signal Cable Between the NPMI and the
DSCB in the BTS3012AE
The monitoring transfer signal cable between the NPMI and the DSCB connects the NPMI and
the DSCB. The cable transmits the alarm information collected by the NPMI to the DSCB.

Functions
The monitoring transfer signal cable between the NPMI and the DSCB connects the NPMI and
the DSCB. The cable transmits the alarm information collected by the NPMI to the DSCB.

Appearance
Figure 5-25 shows the monitoring transfer signal cable between the NPMI and the DSCB.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-67

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-25 Monitoring transfer signal cable between the NPMI and the DSCB
1
View A
Lable1

1 A
2

X1

View B
1
2
3
4

Lable2

X2
Lable3

B
X3

Lable4

X4

View C
Pos.1

Lable5
X9
X5

Pos.36

Lable6
X6

Lable7

X7
Lable8
X8

(1) Common 2-pin connector

(2) Common 4-pin connector

(3) MD36 connector

Pin Assignment
Table 5-49 lists the pin assignment of the monitoring transfer signal cable between the NPMI
and the DSCB.
Table 5-49 Pin assignment of the monitoring transfer signal cable between the NPMI and the
DSCB

5-68

Wire

One End

The Other End

Color

Wire Type

X1.1

X9.6

Blue

Twisted pair

X1.2

X9.7

White

X2.1

X9.8

Orange

X2.2

X9.9

White

X3.4

X9.22

Green

X3.3

X9.24

White

X4.3

X9.25

Brown

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair
Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

Wire

5 BTS3012AE Cables

One End

The Other End

Color

X4.4

X9.31

White

X5.3

X9.26

Grey

X6.3

X9.27

Brown

X7.3

X9.28

Blue

X8.3

X9.29

Red

Wire Type

Twisted pair

Twisted pair

Installation Positions
Table 5-50 lists the installation positions of the monitoring transfer signal cable between the
NPMI and the DSCB.
Table 5-50 Installation positions of the monitoring transfer signal cable between the NPMI and
the DSCB
Signal Cable

One End

The Other End (MD36 Male


Connector)

Monitoring
transfer signal
cable between the
NPMI and the
DSCB

The two common 2-pin connectors


connect to ports JK1 and JK2 on
the NPMI.

Connects to port TO NPMI on the


DSCB

The six common 4-pin connectors


connect to ports JTD1, JTD2, and
JTD4JTD7 on the NPMI.

5.5.15 Diversity Receive Short-Circuiting Cable of the BTS3012/


BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the
diversity receive short-circuiting cable.

Function
The diversity receive short-circuiting cable is used to transfer the diversity receive signals from
the antenna subsystem when the DFCU/DFCB is used.

Appearance
Figure 5-26 shows the structure of the diversity receive short-circuiting cable.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-69

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-26 Structure of the diversity receive short-circuiting cable


1

RF Rx Cable

(1) SMA elbow male connector

Pin Assignment
None.

Installation Positions
Table 5-51 describes the installation positions of the diversity receive short-circuiting cable.
Table 5-51 Installation positions of the diversity receive short-circuiting cable
Cable Type

One End

Other End

Diversity receive
short-circuiting
cable

Connects to the RXDOUT port on the DFCU/


DFCB panel

Connects to the HL-IN port on the DFCU/


DFCB panel

5.5.16 Four-In-One Short-Circuiting Cable of the BTS3012/


BTS3012AE
This cable describes the function, structure, pin assignment, and installation positions of the
four-in-one short-circuiting cable.

Function
The four-in-one short-circuiting cable is used to combine four routes of TX signals when the
DFCU or DFCB is used. It can be used to combine six routes of TX signals when the DFCU
and DFCB is cascaded.

Structure
Figure 5-27 shows the structure of the four-in-one short-circuiting cable.
Figure 5-27 Structure of the four-in-one short-circuiting cable
1

1
RF Tx Cable

(1) N elbow male connector

5-70

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Pin Assignment
None.

Installation Positions
Table 5-52 describes the installation positions of the four-in-one short-circuiting cable.
Table 5-52 Installation positions of the four-in-one short-circuiting cable
Type

One End

Other End

Four-in-one shortcircuiting cable

Connects to the TXCOM port on the DFCU


panel

Connects to the TX-DUP port on the DFCU


panel

Connects to the COM1


or COM2 port on the
DFCB panel

Connects to the TX-DUP port on the DFCB


panel

5.5.17 Signal Cable Between the DFCB and the DFCU in the
BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the signal
cable between the DFCB and the DFCU.

Function
The signal cable between the DFCB and the DFCU is used to transmit two routes of combined
RF signals (two-in-one) to the DFCU so that the DFCU can combine six routes of RF signals
into one route for transmission.

Structure
Figure 5-28 shows the structure of the signal cable between the DFCB and the DFCU.
Figure 5-28 Structure of the signal cable between the DFCB and the DFCU
1

1
RF Tx Cable

(1) N elbow male connector

Pin Assignment
None.
Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-71

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Installation Positions
Table 5-53 describes the installation positions of the signal cable between the DFCB and the
DFCU.
Table 5-53 Installation positions of the signal cable between the DFCB and the DFCU
Type

One End

Other End

Signal cable
between the
DFCB and the
DFCU

Connects to the COM-IN


port on the DFCU panel

Connects to the COM1 or COM2 port on the


DFCB panel

5.5.18 DPMU Monitoring Cable for the BTS3012AE


The DPMU monitoring cable connects the NPMI and the DPMU. It transmits the sensor signals
collected by the NPMI to the DPMU.

Functions
The DPMU monitoring cable connects the NPMI and the DPMU. It transmits the sensor signals
collected by the NPMI to the DPMU.

Appearance
Figure 5-29 shows the DPMU monitoring cable.
Figure 5-29 DPMU monitoring cable
View A
Pos.50
Pos.1

A
2
W

View B
Pos.50

X1
X2

(1) MD50 male connector

Pos.1

(2) MD50 male connector

Pin Assignment
Table 5-54 lists the pin assignment of the DPMU monitoring cable.

5-72

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-54 Pin assignment of the W wire

Issue 01 (2007-09-10)

Pin of the X1 End


(MD50 Connector)

Pin of the X2 End


(MD50 Connector )

Wire Color

Wire Type

X1.1

X2.1

White

Twisted pair

X1.2

X2.2

Blue

X1.3

X2.3

White

X1.4

X2.4

Orange

X1.5

X2.5

White

X1.8

X2.8

Green

X1.9

X2.9

White

X1.10

X2.10

Brown

X1.11

X2.11

White

X1.12

X2.12

Grey

X1.13

X2.13

Red

X1.14

X2.14

Blue

X1.16

X2.16

Red

X1.17

X2.17

Orange

X1.18

X2.18

Red

X1.19

X2.19

Green

X1.20

X2.20

Red

X1.21

X2.21

Brown

X1.22

X2.22

Red

X1.23

X2.23

Grey

X1.24

X2.24

Black

X1.25

X2.25

Blue

X1.27

X2.27

Black

X1.28

X2.28

Orange

X1.29

X2.29

Black

X1.30

X2.30

Green

X1.31

X2.31

Black

X1.32

X2.32

Brown

X1.33

X2.33

Black

Huawei Technologies Proprietary

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair

Twisted pair
5-73

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Pin of the X1 End


(MD50 Connector)

Pin of the X2 End


(MD50 Connector )

Wire Color

X1.34

X2.34

Grey

X1.43

X2.43

Yellow

X1.44

X2.44

Blue

Wire Type

Twisted pair

Installation Positions
Table 5-55 lists the installation positions of the DPMU monitoring cable.
Table 5-55 Installation positions of the DPMU monitoring cable
Signal Cable

One End (MD50 Male


Connector)

The Other End (MD50 Male


Connector)

DPMU
monitoring
cable

Connects to port COM on the


DPMU

Connects to port J1 on the NPMI

5.5.19 Alarm Cable for the MCB of the BTS3012AE Battery


The alarm cable for the MCB of the BTS3012AE battery connects the battery and the NPMI. It
transmits the voltage information about the battery to the NPMI.

Functions
The alarm cable for the MCB of the BTS3012AE battery connects the battery and the NPMI. It
transmits the voltage information about the battery to the NPMI.

Appearance
Figure 5-30 shows the alarm cable for the MCB of the battery.
Figure 5-30 Alarm cable for the MCB of the battery
1
1
2

2
A

A
(1) Common 2-pin connector

(2) Common female connector

(3) OT terminal

Pin Assignment
None.
5-74

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Installation Positions
Table 5-56 lists the installation positions of the alarm cable for the MCB of the battery.
Table 5-56 Installation positions of the alarm cable for the MCB of the battery
Signal Cable

One End (Common Female


Connector)

The Other End (OT Terminal)

alarm cable for the


MCB of the battery

Connects to the port FU_ALM


on the NPMI

Connects to the MCB terminal near


the battery

5.5.20 Alarm Cable for the BTS3012AE Lightning Arrester


The alarm cable for the lightning arrester connects the AC lightning arrester and the NPMI. It
transmits the information about the lightning arrester to the NPMI.

Functions
The alarm cable for the lightning arrester connects the AC lightning arrester and the NPMI. It
transmits the information about the lightning arrester to the NPMI.

Appearance
Figure 5-31 shows the alarm cable for the lightning arrester.
Figure 5-31 Alarm cable for the lightning arrester
2
1
X2

W1

W2
X1
View A

X3

1
2
3
4

(1) Common 4-pin connector

(2) Common connector

Pin Assignment
None.

Installation Positions
Table 5-57 lists the installation positions of the alarm cable for the lightning arrester.
Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-75

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-57 Installation positions of the alarm cable for the lightning arrester
Cable

One End (Common 4-Pin


Connector)

The Other End (Common


Female Connector)

Alarm cable for the


lightning arrester

Connects to the port JTD3 on the


NPMI through the front of the
cabinet

Connects to the lightning arrester

5.5.21 Signal Cable for the Humidity and Temperature Sensor of


the BTS3012AE
The signal cable for the humidity and temperature sensor connects the humidity and temperature
sensor and the NPMI. It transmits the information about the humidity and temperature of the
battery cabin from the humidity and temperature sensor to the NPMI.

Functions
The signal cable for the humidity and temperature sensor connects the humidity and temperature
sensor and the NPMI. It transmits the humidity and temperature information about the battery
cabin from the humidity and temperature sensor to the NPMI.

Appearance
Figure 5-32 shows the signal cable for the humidity and temperature sensor.
Figure 5-32 Signal cable for the humidity and temperature sensor
2
X2

1
W1
A
W4

X1

X3
X4
X5

View A

1
2
3
4

(1) Common 4-pin connector

(2) Common connector

Pin Assignment
Table 5-58 lists the pin assignment of the signal cable for the humidity and temperature sensor.

5-76

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-58 Pin assignment of the signal cable for the humidity and temperature sensor
Pin of 4-Pin
Connector

Common Connector

Wire Color

X1.1

X2

Red

X1.2

X3

White

X1.3

X4

Red

X1.4

X5

Green

Installation Positions
Table 5-59 lists the installation positions of the signal cable for the humidity and temperature
sensor.
Table 5-59 Installation positions of the signal cable for the humidity and temperature sensor
Signal Cable

Common 4-Pin Connector

Common Connector

Signal cable for the


humidity and
temperature sensor

Connects to the port TEM_HUM


on the NPMI through the back of
the cabinet

Connects to the temperature and


humidity sensor

5.5.22 Signal Cable for the Door Control Sensor of the BTS3012AE
The signal cable for the door control sensor connects the door control sensor and the NPMI. It
transmits the open and close information about the door from the door control sensor to the
NPMI.

Functions
The signal cable for the door control sensor connects the door control sensor and the NPMI. It
transmits the open and close information about the door from the door control sensor to the
NPMI.

Appearance
Figure 5-33 shows the signal cable for the door control sensor.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-77

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-33 Signal cable for the door control sensor


2

W1

X1

3
A

W2

X2

View A
1
2

X3
4

W3

X4

W5

W4

X5

X6

(1) 250-type parallel connector (2) Common 2-pin connector (3) 4-pin connector (4) Heat-shrinkable tube

Pin Assignment
Table 5-60 lists the pin assignment of the signal cable for the door control sensor.
Table 5-60 Pin assignment of the signal cable for the door control sensor
Pin of Parallel
Terminal 250

Pin of 2-Pin
Connector

Wire Color

X1

X3.1

Red

X2

X3.2

Red

Installation Positions
Table 5-61 lists the installation positions of the signal cable for the door control sensor.
Table 5-61 Installation positions of the cable for the door control sensor
Signal Cable

Common 2-Pin Connector

Parallel Terminal

Signal cable for the


door control sensor

Connects to the port DOOR


on the NPMI through the back
of the cabinet

Parallel connectors X1 and X2


connect to the tact switch on the
front door of the cabinet. Parallel
connectors X4 and X5 connect to
the tact switch on the back door of
the cabinet. Connector X6 is
reserved for transmitting door
status signals of combined
cabinets.

NOTE

Remove W5 in case of combined cabinets, and then connect the cable for the door control sensor on the
other cabinet door to the W5 port.

5-78

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5.5.23 Signal Cable for the Smoke Sensor of the BTS3012AE


The signal cable for the smoke sensor connects the smoke sensor and the NPMI. It transmits the
smoke information collected by the smoke sensor to the NPMI.

Functions
The signal cable for the smoke sensor connects the smoke sensor and the NPMI. It transmits the
smoke information collected by the smoke sensor to the NPMI.

Appearance
Figure 5-34 shows the signal cable for the smoke sensor.
Figure 5-34 Signal cable for the smoke sensor
2
1
X2

W1

W2
X1
View A

X3

1
2

(1) Common 2-pin connector

(2) Common connector

Pin Assignment
Table 5-62 shows the pin assignment of the signal cable for the smoke sensor.
Table 5-62 Pin assignment of the signal cable for the smoke sensor
Wire

Wire Color

W1

Red

W2

White

Installation Positions
Table 5-63 lists the installation positions of the signal cable for the smoke sensor.
Table 5-63 Installation positions of the cable for the smoke sensor

Issue 01 (2007-09-10)

Signal Cable

Common 2-Pin Connector

Common Connector

Signal cable for the


smoke sensor

Connects to the port SMOKE on


the NPMI through the back of
the cabinet

Connects to the smoke sensor

Huawei Technologies Proprietary

5-79

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5.5.24 Cable for the Water Sensor of the BTS3012AE


The signal cable for the water sensor connects the water sensor and the NPMI. It transmits the
water information collected by the water sensor to the NPMI.

Functions
The signal cable for the water sensor connects the water sensor and the NPMI. It transmits the
water information collected by the water sensor to the NPMI.

Appearance
Figure 5-35 shows the signal cable for the water sensor.
Figure 5-35 Signal cable for the water sensor
2
1
A
View A
1
2
3
4

(1) Common 4-pin connector

(2) Common female connector

Pin Assignment
None.

Installation Positions
Table 5-64 lists the installation positions of the cable for the water sensor.
Table 5-64 Installation positions of the cable for the water sensor
Signal Cable

Common 4-Pin Connector

Common Connector

Signal cable for the


water sensor

Connects to the port WATER on


the NPMI through the back of the
cabinet

Connects to the water sensor

5.6 RF Cables for the BTS3012AE


The RF cables for the BTS3012AE are the RF signal cables and RF jumpers for the BTS3012AE.
5.6.1 RF Signal Cables of the BTS3012/BTS3012AE
This part describes the function, structure, pin assignment, and installation positions of the RF
signal cables.
5-80

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

5.6.2 RF Jumpers for the BTS3012AE


The RF jumpers connect the ANT port on the DDPU or DFCU and the feeder. The RF jumpers
are used for the signal exchange between the BTS and the antenna system. The RF jumpers for
the BTS3012AE are of two types: 1/4-inch RF jumper and 1/2-inch RF jumper.

5.6.1 RF Signal Cables of the BTS3012/BTS3012AE


This part describes the function, structure, pin assignment, and installation positions of the RF
signal cables.

Function
The RF signal cables are classified into RF RX signal cable and RF TX signal cable.
l

The RF RX signal cable connects the DDPU/DFCU/DFCB with the DTRU. This cable is
used to transmit UL signals.

The RF TX signal cable connects the DDPU/DFCU/DFCB with the DTRU. This cable is
used to transmits DL signals.

Structure
Figure 5-36 shows the structure of the RF RX signal cable and the RF TX signal cable.
Figure 5-36 Structure of the RF RX signal cable and the RF TX signal cable

(1) SMA elbow male connector

(2) N elbow male connector

Pin Description
None

Installation Positions
Table 5-65 describes the installation positions of the RF signal cables.
Table 5-65 Installation positions of the RF signal cables

Issue 01 (2007-09-10)

Cable

One End

Other End

RF TX signal cable

Connects to the TX port on


the DTRU panel

Connects to the TX port on the


DDPU/DFCU/DCOM/DFCB panel

Huawei Technologies Proprietary

5-81

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Cable

One End

Other End

RF RX signal cable

Connects to the RX port on


the DTRU panel

Connects to the RX port on the


DDPU/DFCU/DCOM/DFCB panel

NOTE

In inter-cabinet cell configuration, the RF RX cables should be connected between two cabinets. The
BTS3012 cabinet uses two 2.8 m long RF RX cables to set up the connection between the two cabinets.
The RF RX cable use SMA coaxial connectors at both ends.

5.6.2 RF Jumpers for the BTS3012AE


The RF jumpers connect the ANT port on the DDPU or DFCU and the feeder. The RF jumpers
are used for the signal exchange between the BTS and the antenna system. The RF jumpers for
the BTS3012AE are of two types: 1/4-inch RF jumper and 1/2-inch RF jumper.

Functions
The RF jumper connects the ANT port on the DDPU or DFCU and the feeder. The RF jumper
is used for the signal exchange between the BTS and the antenna system.

Appearance
One end of the 1/4-inch jumper is a DIN male connector and the other end is a DIN female
connector. Both ends of the 1/2-inch jumper are DIN male connectors.
Figure 5-37 shows the 1/4-inch RF jumper.
Figure 5-37 1/4-inch RF jumper
2

(1) DIN male connector

(2) DIN female connector

Figure 5-38 shows the 1/2-inch RF jumper on the cabinet side.


Figure 5-38 1/2-inch RF jumper on the cabinet side

(1) DIN male connector

(2) DIN male connector

Pin Assignment
None.
5-82

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Installation Positions
Table 5-66 lists the installation positions of the RF jumpers.
Table 5-66 Installation positions of the RF jumpers
Cable

One End (DIN Male


Connector)

The Other End

1/4-inch RF
jumper

Connects to the port ANT on the


top of the DDPU or DFCU

At the cable hole for the RF


jumpers at the bottom of the
cabinet, the DIN female connector
connects to the DIN male
connector for the 1/2-inch jumper
on the cabinet side.

1/2-inch RF
jumper on the
cabinet side

Connects to the DIN female


connector of the 1/4-inch jumper at
the cable hole for RF jumpers

Connects to the feeder of the


antenna system

5.7 Cables for the Built-in Battery of the BTS3012AE


The cables for the built-in battery are the GND cable, -48 V power cable, cable between the
wiring copper bar and the battery, cable between batteries, and signal cable for the temperature
sensor of the built-in battery.

Function
The cables for the built-in battery are the GND cable, -48 V power cable, cable between the
wiring copper bar and the battery, cable between batteries, and signal cable for the temperature
sensor of the built-in battery.
l

The GND cable and the 48 V power cable provide DC power.

The cable between the wiring copper bar and the battery and the cable between batteries
connect each battery in serial to form the built-in battery power supply system.

The signal cable for the temperature sensor of the built-in battery connects the built-in
battery and the NPMI. It transmits the temperature information collected by the temperature
sensor to the NPMI.

Appearance
The GND cable is red in color with the cross-sectional area of 25 mm2, as shown in Figure
5-39.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-83

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Figure 5-39 GND cable for the battery


1

3
W

(1) Bare pressure terminal

(2) Heat-shrink tube

(3) Bare pressure terminal

The 48 V power cable is black in color with the cross-sectional area of 25 mm2, as shown in
Figure 5-40.
Figure 5-40 48 V power cable for the battery
2

3
W

(1) Bare pressure terminal

(2) Heat-shrink tube

(3) Bare pressure terminal

The cable between the copper wiring bar and the battery is black in color with the cross-sectional
area of 16 mm2. It connects the battery and the copper wiring bar on the left inside the 50 AH
battery cabin.
The cable between batteries is black in color with the sectional area of 16 mm2.
Figure 5-41 shows the signal cable for the temperature sensor of the built-in battery.
Figure 5-41 Signal cable for the temperature sensor of the built-in battery
1
2

(1) OT terminal

Common 2-pin connector

Pin Description
None

Installation Positions
Table 5-67 shows the installation positions of the signal cables for the built-in battery.

5-84

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-67 Installation positions of the cables for the built-in battery
Cable Name

One End

The Other End

GND cable

Connects to the positive lead of


the wiring copper bar on the left
part in the 50 AH battery cabin

Connects to the RTN at the rear


of the power subrack

48 V power cable

Connects to the negative lead of


the wiring copper bar on the left
part in the 50 AH battery cabin

Connects to the RTN at the rear


of the power subrack

Cable between the


wiring copper bar and
the storage batteries

Connects to the wiring copper


bar on the left part in the 50 AH
battery cabin

Connects to the positive or


negative lead of the storage
batteries

Cable between
batteries

The red connector connects to


the positive lead of one storage
battery.

The black connector connects to


the negative lead of the other
storage battery.

Signal cable for the


temperature sensor of
the built-in battery

The OT terminal is fixed on the


side of the 150 AH battery cabin.

The common 2-pin connector


connects to port BAT_TEM1 on
the NPMI.

5.8 Cable Between the BTS3012AE and the Auxiliary


Equipment
The cables between the BTS3012AE and the auxiliary equipment are the signal cable for the
alarm box, power cable between the IBBS and the BTS3012AE, equipotential cable between
the IBBS and the BTS3012AE, and cables for the IBBS door control sensor and temperature
sensor.
5.8.1 Signal cable of the external environment alarm box in the BTS
This part describes the function, structure, pin assignment, and installation positions of the signal
cable of the external environment alarm box in the BTS.
5.8.2 Power Cables Between the IBBS and the BTS3012AE
The power cables between the IBBS and the BTS3012AE introduce the power from the IBBS
battery cabinet to the BTS3012AE cabinet.
5.8.3 Equipotential Cable Between the IBBS and the BTS3012AE
The equipotential cable between the IBBS and the BTS3012AE keeps the equal potential
between the IBBS and the BTS3012AE cabinet.
5.8.4 Cable for the Door Control Sensor and Temperature Sensor
The cable for the door control sensor and temperature sensor reports the door control alarm
signals and the temperature alarm signals of the IBBS battery cabinet to the BTS3012AE.

5.8.1 Signal cable of the external environment alarm box in the BTS
This part describes the function, structure, pin assignment, and installation positions of the signal
cable of the external environment alarm box in the BTS.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-85

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Function
The signal cable of the external environment alarm box is used to transmit the alarm signals to
the BTS. This helps the BTS take actions to clear the relevant alarms.

Appearance
Figure 5-42 shows the structure of the signal cable of the external environment alarm box.
Figure 5-42 Structure of the signal cable of the external environment alarm box
View B

Pos.1

View A
Pos.1
A

B
W
Pos.9

X1

X2

(1) DB9 male connector

Pos.9

(2) DB9 male connector

Pin Description
Table 5-68 describes the pin assignment for the signal cable of the external environment alarm
box.
Table 5-68 Pin assignment for the signal cable of the external environment alarm box
Pin at the X1 End

Pin at the X2 End

Wire Type

Remarks

X1.3

X2.2

Twisted pair

WARNING_T+

X1.7

X2.6

X1.2

X2.3

X1.6

X2.7

WARNING_TTwisted pair

WARNING_R+
WARNING_R-

Installation Positions
Table 5-69 shows the installation positions of the signal cable for the external environment alarm
box.
Table 5-69 Installation positions of the signal cable for the external environment alarm box

5-86

BTS Type

One End (DB9 Male


Connector)

Other End (DB9 Male Connector)

BTS3012

Connects to the COM1 or


COM2 port on the DSAC

The two core wires at the bare wire end


connect to relevant control devices.

BTS3012AE

Connects to the EAC port on


the DMLU panel

The two core wires at the bare wire end


connect to relevant control devices.

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

BTS Type

One End (DB9 Male


Connector)

Other End (DB9 Male Connector)

BTS3006C

Connects to the DB9


connector of the BTS3006C/
BTS3002E external alarm
cable

The two core wires at the bare wire end


connect to relevant control devices.

BTS3002E

Connects to the DB9


connector of the BTS3006C/
BTS3002E external alarm
cable

The two core wires at the bare wire end


connect to relevant control devices.

5.8.2 Power Cables Between the IBBS and the BTS3012AE


The power cables between the IBBS and the BTS3012AE introduce the power from the IBBS
battery cabinet to the BTS3012AE cabinet.

Functions
The power cables between the IBBS and the BTS3012AE introduce the power from the IBBS
battery cabinet to the BTS3012AE cabinet.

Appearance
There are two power cables between the IBBS and the BTS3012AE:
l

The GND cable is red in color with a cross-sectional area of 35 mm2.

The 48 V cable is black in color with a cross-sectional area of 35 mm2.

Figure 5-43 shows the power cables between the IBBS and the BTS3012AE.
Figure 5-43 Power cables between the IBBS and the BTS3012AE

Pin Assignment
None.

Installation Positions
Table 5-70 lists the installation positions of the power cables between the IBBS and the
BTS3012AE.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-87

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-70 Installation positions of the power cable between the IBBS and the BTS3012AE
Cable

One End (OT


Terminal)

The Other End (OT Terminal)

GND cable

Connects to the
positive lead of the
wiring copper bar for
the external battery
cabinet

Connects to the RTN/+ terminal of the


wiring copper bar in the 48 V 50 AH
battery cabin in the BTS3012AE
cabinet

48 V cable

Connects to the
negative lead of the
wiring copper bar for
the external battery
cabinet

Connects to the 48 V terminal of the


copper wiring bar in the 48 V 50 AH
battery cabin in the BTS3012AE
cabinet.

5.8.3 Equipotential Cable Between the IBBS and the BTS3012AE


The equipotential cable between the IBBS and the BTS3012AE keeps the equal potential
between the IBBS and the BTS3012AE cabinet.

Functions
The equipotential cable between the IBBS and the BTS3012AE maintains the equal potential
between the IBBS and the BTS3012AE cabinet.

Appearance
The equipotential cable is green and yellow in color with a cross-sectional area of 25 mm2. Both
ends of the cable are OT terminals. Figure 5-44 shows the equipotential cable.
Figure 5-44 Equipotential cable between the IBBS and the BTS3012AE

Pin Assignment
None.

Installation Positions
Table 5-71 lists the installation positions of the equipotential cable between the IBBS and the
BTS3012AE.

5-88

Huawei Technologies Proprietary

Issue 01 (2007-09-10)

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-71 Installation positions of the equipotential cable between the IBBS and the
BTS3012AE
Cable

One End (OT


Terminal)

The Other End (OT Terminal)

Equipotential cable
between the IBBS and the
BTS3012AE

Connects to the
protection grounding
bar at the bottom of the
BTS3012AE cabinet

Connects to the protection grounding


bar in the IBBS battery cabinet

5.8.4 Cable for the Door Control Sensor and Temperature Sensor
The cable for the door control sensor and temperature sensor reports the door control alarm
signals and the temperature alarm signals of the IBBS battery cabinet to the BTS3012AE.

Functions
The cable for the door control sensor and temperature sensor reports the door control alarm
signals and the temperature alarm signals of the IBBS battery cabinet to the BTS3012AE.

Appearance
Figure 5-45 shows the cable for the door control sensor and temperature sensor.
Figure 5-45 Cable for the door control sensor and temperature sensor
1
3

(1) Two bare wires (white and green) (2) Common 2-pin connector (3) Four bare wires (white, green, red, and
black)

Pin Assignment
None.

Installation Positions
Table 5-72 lists the installation positions of the cable for the door control sensor and temperature
sensor.

Issue 01 (2007-09-10)

Huawei Technologies Proprietary

5-89

BTS3012AE
Hardware Description(for FFU)

5 BTS3012AE Cables

Table 5-72 Installation positions of the cable for the door control sensor and temperature sensor
Cable

One End

The Other End

Cable for the door control


sensor and temperature
sensor

The four bare wires connect


to the wiring terminal of the
external battery cabinet.

The 2-pin connector connects


to the port BAT_TEM2 on
the NPMI.
The two bare wires connect to
the cable for the door control
sensor on the BTS3012AE
cabinet.

5-90

Huawei Technologies Proprietary