2 activate alarm output COM1/NO1. Alarm inputs 3 and 4 activate alarm output
COM2/NO2.
(VS-YH300)
(VS-YH400)
(DG85)
5. Activate the wired zones for G70-GTW. When in programming status, select menu of Zone attribute,
then input the zone number which you need to activate, in Bypass zone menu, select No).
(VS-YH300)
Above article shows the NC connection (the default setting of PIR relayoutput are NC)
8. How to wire more than one (example: 2 or 3) wired sensors into one (single) zone ?
Actually wiring more than one wired sensors into a single zone is pretty easy, you just need to
connect them in series, then only put the EOL resistor to the last of wired sensor. After finish the
wiring, you need to power up the sensor, then using the multi-meter to measure the resistor value
in this zone. If the resistor value is 2.2K, then it means the wiring is correct.
Fresnel lens
SMT design adopter
Installation:
1. Install at the outdoor, place with petss, air-condition nearby, direct sunshine, heat source and under the
rotating objects should be avoided.
2. Surface of installation should be firm with no vibration.
3. Installing the detector in the place where intruder pass easily.
Installation Step:
1.
2.
3.
4.
5.
6.
Operation Instruction:
1. Relay Jumper: Choose NC or NO to set the state of alarm output. You should choose different alarm
output in accordance with host.
Short 1&2: N.O.
Short 2&3: N.C. (default set).
2. Pulse Jumper: You can adjust the sensitivity and anti RF interference by choosing the Pulse Jumper.
Short 1&2: Class 1 pulse, the sensitivity is highest, adapt to general environment.
Short 2&3: Class 2 pulse, anti-RF interference is high, adapt to the environment with strong RF
interference.
Shut off: Class 3 pulse, the sensitivity is lower, and the anti-RF interference is highest, adapt to the
environment with exceeding RF interference.
3. LED Jumper: Control LED indicator, without effect of detector normal work.
Short 1&2: set LED ON
Short 2&3: set LED OFF
LED can be shut off for concealment of the detector after test.
Product Testing:
Turning on power and LED indicator on, the detector comes to state of self-check, it takes about 60s, after
that it is in the state of normal work. Connershould walk parallel with the installed detector in the testing
area. LED lighting means the detector is in the state of alarm
This article is related to wire (connect) wired sensors (including IR beam, PIR motion
sensor, Door Magnetic Contact) to wired alarm system. Nowadays many customers are
buying alarm system to protect their residential and commercial business. Install
wireless alarm kit is pretty easy, but wiring the wired alarm system may turn to
nightmare for un-professional people. In order to help our customers on installation our
security alarm systems, we herein provide these information.
Wiring the wired IR beam sensor to wired GSM alarm system:
The IR beam sensor is the one of professional security equipment to provide perimeter
protection, it creates invisible fence around your premises. The sensor consists of
transmitter and receiver. we herein provide the wiring diagram as below:
How to connect two IR beams into a single zone ? The diagram as below:
Explanation: PIR sensor get the power supply from alarm panel (AUX and GND), the
dry contact output (from PIR) connect with tamper (TMP) and zone 1 in series, also
connecting with EOL resistor is essential. The real connection photo as below:
If you have any doubles about wiring sensors to wired alarm system, you can either
contact us by sending E-mail to techsupport at hkvstar.com or click the feedback icon
on the right column to chat with us, we are willing to give you help.
6.1 Alarm input port specification
1 channels alarm input. Alarm input type unlimited.
The grounding and the com port of the alarm sensor are parallel
(The alarm sensor is external power supply) .
The grounding of the alarm and the DVR should be shared.
The NC port of the alarm sensor must be connected with the
DVR alarm input port.
The grounding of the power supply and the alarm sensor must
be shared when used in external power supply.
2.6.2 Alarm output port specification
1 channels alarm output. There is external power supply when
using the external alarm equipment.
Please refer to the relay relevant parameters to avoid the
overload that damages main machine.
3. Fix the screw into the wall firmly, then hang the detector.
4. Avoid installing the detector close to the following sources of interference: Direct air flow from vents,
fans, doors, windows, sources of steam, oil vapor...etc.
5. All wires installation must accord with the National and Local effective laws and criteria. The wires must
have the suitable size and colorful marks for avoiding connecting error. And unsuitable connection of wires
will result in the alarm error while leaking happened.
6. Test: to test the installed detector while using independently or in network, you can give some gas
around in distance of 5cm to the gas convection holes by using un-ignition lighter. Testing frequently may
result in reducing the sensitivity of the detector. The alarm density of gas is set according with the criteria
of national standard. The detector will stop alarm and resume to the detecting state while the gas density
reduced to lower than the alarm level. The alarm output switches can connect with the hardwired alarm
system.
7. Maintenance: The user must brush and clean the gas convection holes with a little cleanser every three
months, and must retest the detector after cleaning for preventing the cleanser into the detector.
8. Handle the alarm: The gas detector alarms while the gas density in air exceed the alarm level. The
relative handle as below:
a. Shut down the tube valve right away.
b. Open the window and make the air flow rapidly.
c. Extinguish all fire sources and do not use anything can make fire: eg. lighters, matches,,, etc.
d. Avoiding open or close the power all kinds of electric equipment.
e. Check the reason of gas leaking, and notify the relative departments and professional person in time.
C) If you want to connect gas detector to hardwired alarm system, then connection diagram as
below:
The old idiom says Theres no smoke without fire. The basic fire alarm system is just a simple smoke
detector which can detect the smoke and set off alarm. Install smoke detector is the effective and low-cost
way to escape from fire disaster.
How install smoke detector is so important?
Reports from Emergency Management Agencys (FEMA) United States, Each year estimated 1,800 fatal
residential fires, and cause 2,636 deaths, 725 injuries, and $196 million in property loss in USA.
The reports also indicates that majority of fatal fires happen when people are asleep, due to unaware of
the fire and without enough time to escape.
We think that many of countries with high rate of fatal fires than USA, due to lock of management and
without adequate investment (fire equipment) from government.
How smoke detector works?
Smoke detectors are mounted on the top of floor for 24 hours working, and when it detect the smoke
(intense), it will make sounds and flashing to alert people, also it is connecting with an alarm system, then
it will go through alarm system and report to Central Monitoring Station.
Where should install the smoke detector?
Smoke detector should be installed on each of rooms (bedrooms, storage room, reading roometc) and
the corridor, as well as the lobby. When install smoke detector, you need to place them on the center of
top ceiling, if you want to install on the wall, then they should be installed below the ceiling 6-12 inches.
Standalone smoke detector: working as a single unit, detection of smoke, then buzz and flash
alarm.
Hardwired smoke detector: working as a single unit and using cable to connect with hardwired
alarm system (can be burglar alarm system or fire alarm panel).
Wireless smoke detector: also can work as a single unit, but it is using wireless technology to
connect with wireless alarm system (only burglar alarm system, as we know, we cant find
wireless fire alarm panel so far).
Dont install smoke detector near the path of bathroom and kitchen equipment. These place are
easily cause false alarm.
2.
Dont install smoke detector near the doors, windows, air conditioner.
3.
Monthly test and check smoke detector for insuring they can work correctly.
4.
Replace the battery each a year. Most of smoke detector with low-voltage alarm function, when
smoke detector start to flash, then you need to replace the battery.
5.
Many people are thinking get a set of burglar alarm system for theirs residential. Before purchase
burglar alarm system, please add extra smoke detectors for your fire alarm.
2.
3.
Dont smoking inside of house, after smoking, dumping cigarette butts in the trash, make sure
smoke is extinct?
4.
Carefully handle and operation the electronic device, especially for heat generated device. Any
problem on electricity, turn to professionals help.
2.
Leave the building as quickly as possible. Touch doors to feel if they were hot before opening
them. Use an alternate exit if necessary. Crawl along the floor, and do stop to collect anything.
3.
4.
5.
Do not go back inside a burning building. Wait for the fire department to arrive.
Note: These guidelines will assist you in the event of a fire, however, to reduce the chance that fires will
start, practice fire safety rules and prevent hazardous situations