You are on page 1of 37

Jurutera Perunding Akal Sdn Bhd

Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet
1
Rev.
MLNG Fire Fighting Training Centre, Bintulu

Job Title:
Subject:

Drainage Design Analysis

Client : MLNG S/B

Made by:

CALCULATION SHEET

FJ
Checked by: CCL

Description

Reference

Basic For Drainage Design


The drainage design for this development is based on "The Urban Drainage Design Standards and Procedure
For Peninsular Malaysia".
All drains are sized in accordance to storm water discharge from the respective catchment with run off
coefficient of 0.90 (paved area) and 0.75 (for turfing area). All the drains width are provided in accordance to BDA's
standards and requirement for the road and perimeter drain.
The discharge estimation for each road side drain and perimeter drains are calculated as follow;
Q

CIA

Q
C
I
A

=
=
=
=

the peak discharge in cubic meter per second


the coefficient runoff. This is taken as 0.90 for paved area and 0.75 for green area
the average intensive of rainfall = 107 mm/hr (10 years)
catchment area

Where:

For main drainage lines, the discharge are determined by the "Modified Rational Formula" as shown below
Q

Cs C I A

Q
Cs
C
I

=
=
=
=

the peak discharge in cubic meter per second


the storage coefficient for the respective catchment
the coefficient runoff. This is taken as 0.90 for paved area and 0.75 for green area
the average intensive of rainfall in meter per second for a duration equal to
time of concentration to and return period T years
catchment area in meter square

Where:

"Manning Formula" is used to calculate the capacity of the drains and box culvert where the formula
is as follow:
Q

Q
A
R
S
n

=
=
=
=
=

AR

the capacity of drains


Area
Hydraulic Radius
Gradient
Manning's roughness coefficient = 0.013 (Earth Drains)

Area Classification For Catchment


Classification of Catchment area are as below:
2
A1
(paved) =
12600 m

A3

A4

A5

Where:

A2

(Turf) =

2
0m

(paved) =

2
1870 m

(Turf) =

2
708.3 m

(paved) =

2
841 m

(Turf) =

2
650 m

(paved) =

2
554 m

(Turf) =

2
441 m

(paved) =

2
1282.5 m

(Turf) =

2
326.5 m

A6

(paved) =

A7

(paved) =

2
570 m
2
800 m

Date: 30.10.08
Date: 30.10.08
Result

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.
Job Title:
Subject:

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet
Tudan Housing

Rev.

Date:

11/20/2014
11/20/2014

Drainage Design Analysis


(450mm Backlane R.C. Drain)

Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:

Description

Reference

Result

1.0 Calculation for capacity of 450mm Backlane R.C Drain


a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area
2
27646 m
(A9)

Where:

Cs
I
A

Q1

=
=
=
=

3
0.829 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

1200 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.6 m
1.2 m
147 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.45 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.54
2.1
0.257
1/300
0.013

Qcap

0.970 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)

Qcap/A
1.80 m/s

0.829 m3/s

>

<

3 m/s

Freeboard
= 0.15m
D

OK

OK

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

Job Title:
Subject:

JPA/P-063 Sheet
Tudan Housing

Rev.

Date:

11/20/2014
11/20/2014

Drainage Design Analysis


(450mm R.C. Drain)

Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:

Description

Reference

Result

1.0 Calculation for capacity of 450mm R.C Drain


a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area
2
4744 m
(A1a)

Where:

Cs
I
A

Q1

=
=
=
=

3
0.142 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

600 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.6 m
95 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.18
1.2
0.150
1/500
0.013

Qcap

0.175 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
0.97 m/s

<

0.142 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

Job Title:
Subject:

JPA/P-063 Sheet
Tudan Housing

Rev.

Date:

11/20/2014
11/20/2014

Drainage Design Analysis


(450mm R.C. Drain)

Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:

Description

Reference

Result

1.0 Calculation for capacity of 450mm R.C Drain


a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area
2
1870 m
(A2)

Where:

Cs
I
A

Q1

=
=
=
=

3
0.056 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

450 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.45 m
147 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.135
1.05
0.129
1/500
0.013

Qcap

0.118 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
0.88 m/s

<

0.056 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(750mm R.C. Drain) - Drain 12


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A1,A1a,2A7,2A8,A12)
2
16590 m

Where:

Q1

=
=
=
=

3
0.498 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

900 mm

Drain top level, DTL =


Depth (D)
Width (W)
Length (L)

2.15 m

=
=
=

0.6 m
0.9 m
80 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.45 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.405
1.8
0.225
1/500
0.013

Qcap

0.515 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.27 m/s

<

0.498 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 750mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(750mm R.C. Drain) - Drain 12a


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A1,A1a,2A7,2A8,A12)
2
16590 m

Where:

=
=
=
=

Q1

3
0.498 m /s
3
1.205 m /s

Q1+Q3.3+Q3.4 =

b) Capacity for Sub-catchment drain


Drain Size
=

900 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.74 m
0.9 m
80 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.59 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.531
2.08
0.255
1/500
0.013

Qcap

0.735 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
<

Qcap/A
1.38 m/s

<

1.205 m3/s

FAILS

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 750mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(750mm R.C. Drain) - Drain 12b


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A2,A2.1,A3,A3.1)
2
6138 m

Where:

Q1

=
=
=
=

3
0.184 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

600 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.47 m
0.6 m
80 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.32 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.192
1.24
0.155
1/500
0.013

Qcap

0.190 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
0.99 m/s

<

0.184 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 750mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 3.3


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A2,A2.1,A3,A3.1)
2
6138 m

Where:

Q1

=
=
=
=

3
0.184 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

600 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.5 m
0.6 m
346 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.35 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.21
1.3
0.162
1/500
0.013

Qcap

0.214 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.02 m/s

<

0.184 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 3.4


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D12)+A3.4]
2
17435 m

Where:

Q1

=
=
=
=

3
0.523 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

900 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.61 m
0.9 m
346 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.46 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.414
1.82
0.227
1/500
0.013

Qcap

0.531 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.28 m/s

<

0.523 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 4-4.1


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A4,A4.1)
2
2207 m

Where:

Q1

=
=
=
=

3
0.066 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

450 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.45 m
195 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.135
1.05
0.129
1/500
0.013

Qcap

0.118 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
0.88 m/s

<

0.066 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 4.2


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D12b),A4.1,A4.2]
2
10145 m

Where:

Q1

=
=
=
=

3
0.304 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

750 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.55 m
0.75 m
195 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.4 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.3
1.55
0.194
1/500
0.013

Qcap

0.345 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.15 m/s

<

0.304 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(750mm R.C. Drain) - Drain 13


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [AD3.4a,A1b,2A7a,2A8a,2A4.3a,2A9a,2A10a,2A11a,A13]
2
24085 m

Where:

Q1

=
=
=
=

3
0.723 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

1200 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.65 m
1.2 m
203 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.5 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.6
2.2
0.273
1/500
0.013

Qcap

0.868 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.45 m/s

<

0.723 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 750mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(600mm R.C. Drain) - Drain 14


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D4.2),A3.4b,A(D3.4),A14]
2
28910 m

Where:

Q1

=
=
=
=

3
0.867 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

1200 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.66 m
1.2 m
67 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.51 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.612
2.22
0.276
1/500
0.013

Qcap

0.892 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.46 m/s

<

0.867 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 600mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(600mm R.C. Drain) - Drain 15


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A5,A5.1,A6,A6.1,A15)
2
6982 m

Where:

Q1

=
=
=
=

3
0.209 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

600 mm

Drain top level, DTL =


Depth (D)
Width (W)
Length (L)

2.15 m

=
=
=

0.5 m
0.6 m
47 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.35 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.21
1.3
0.162
1/500
0.013

Qcap

0.214 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.02 m/s

<

0.209 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 600mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 17


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A17)
2
2921 m

Where:

Q1

=
=
=
=

3
0.088 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

450 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.45 m
127 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.135
1.05
0.129
1/500
0.013

Qcap

0.118 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
0.88 m/s

<

0.088 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(600mm R.C. Drain) - Drain 17b


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A17b)
2
7029 m

Where:

Q1

=
=
=
=

3
0.211 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

750 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.75 m
127 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.225
1.35
0.167
1/500
0.013

Qcap

0.234 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.04 m/s

<

0.211 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 600mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(750mm R.C. Drain) - Drain 34


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D33a),A(D17b),4A16,4A17)
2
38055 m

Where:

Q1

=
=
=
=

3
1.142 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

1200 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.77 m
1.2 m
132 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.62 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.744
2.44
0.305
1/500
0.013

Qcap

1.159 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.56 m/s

<

1.142 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 750mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 33


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A19,A20)
2
5226 m

Where:

Q1

=
=
=
=

3
0.157 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

600 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.6 m
42 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.18
1.2
0.150
1/500
0.013

Qcap

0.175 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
0.97 m/s

<

0.157 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(750mm R.C. Drain) - Drain 33a


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D18b),A18,A(D33)]
2
11722 m

Where:

Q1

=
=
=
=

3
0.352 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

750 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.57 m
0.75 m
42 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.42 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.315
1.59
0.198
1/500
0.013

Qcap

0.368 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.17 m/s

<

0.352 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 750mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 18b


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A18b)
2
4845 m

Where:

Q1

=
=
=
=

3
0.145 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

600 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.6 m
95 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.18
1.2
0.150
1/500
0.013

Qcap

0.175 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
0.97 m/s

<

0.145 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 18d


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A18f,A18d)
2
3580 m

Where:

Q1

=
=
=
=

3
0.107 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

750 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.75 m
95 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.225
1.35
0.167
1/500
0.013

Qcap

0.234 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.04 m/s

<

0.107 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(900mm R.C. Drain) - Drain 32a


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D18c),A(D33),A(D18e)]
2
10108 m

Where:

Q1

=
=
=
=

3
0.303 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

900 mm

Drain top level, DTL =


Depth (D)
Width (W)
Length (L)

2.15 m

=
=
=

0.5 m
0.9 m
22 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.35 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.315
1.6
0.197
1/500
0.013

Qcap

0.367 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.16 m/s

<

0.303 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 900mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(900mm R.C. Drain) - Drain 27


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A27)
2
2340 m

Where:

Q1

=
=
=
=

3
0.070 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

900 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.65 m
0.9 m
200 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.5 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.45
1.9
0.237
1/500
0.013

Qcap

0.593 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.32 m/s

<

0.070 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 900mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 18c


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A18c)
2
2970 m

Where:

Q1

=
=
=
=

3
0.089 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

750 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.75 m
106 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.225
1.35
0.167
1/500
0.013

Qcap

0.234 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.04 m/s

<

0.089 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(450mm R.C. Drain) - Drain 18e


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A18a,A18e)
2
1912 m

Where:

Q1

=
=
=
=

3
0.057 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

750 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.75 m
22 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.225
1.35
0.167
1/500
0.013

Qcap

0.234 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.04 m/s

<

0.057 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 450mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(900mm R.C. Drain) - Drain 30


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (4A16a,4A17a,A30)
2
21044 m

Where:

Q1

=
=
=
=

3
0.631 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

900 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.7 m
0.9 m
156 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.55 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.495
2
0.248
1/500
0.013

Qcap

0.671 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.36 m/s

<

0.631 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 900mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(750mm R.C. Drain) - Drain 28


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (A28)
2
1360 m

Where:

Q1

=
=
=
=

3
0.041 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

750 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.45 m
0.75 m
125 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.3 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.225
1.35
0.167
1/500
0.013

Qcap

0.234 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.04 m/s

<

0.041 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 750mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(750mm R.C. Drain) - Drain 29


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D32a),A(D28),A29]
2
13353 m

Where:

Q1

=
=
=
=

3
0.401 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

900 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.55 m
0.9 m
140 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.4 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.36
1.7
0.212
1/500
0.013

Qcap

0.440 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.22 m/s

<

0.401 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 750mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(900mm R.C. Drain) - Drain 31


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D18d),A25,A26,A(D28),A31]
2
11262 m

Where:

Q1

=
=
=
=

3
0.338 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

900 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.55 m
0.9 m
190 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.4 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.36
1.7
0.212
1/500
0.013

Qcap

0.440 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.22 m/s

<

0.338 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 900mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(900mm R.C. Drain) - Drain 35


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area
2
6855 m

Where:

Q1

=
=
=
=

3
0.206 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

900 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

0.5 m
0.9 m
125 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
0.35 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

0.315
1.6
0.197
1/500
0.013

Qcap

0.367 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.16 m/s

<

0.206 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 900mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(900mm R.C. Drain) - Drain 35a


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D35),A(D15),A(D14),A(D13),A35a]
2
73553 m

Where:

Q1

=
=
=
=

3
2.207 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

1200 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

1.18 m
1.2 m
125 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
1.03 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

1.236
3.26
0.379
1/500
0.013

Qcap

2.227 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
1.80 m/s

<

2.207 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 900mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(1500mm R.C. Drain) - Drain 35b


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D35a),A(D27),A(D34),A(D30),A35b]
2
144322 m

Where:

Q1

=
=
=
=

3
4.330 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

1500 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

1.52 m
1.5 m
125 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
1.37 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

2.055
4.24
0.485
1/500
0.013

Qcap

4.362 m3/s

Velocity, v

=
=

Where:

n
m2
m
m
(For R.C. Drain)
>

Qcap/A
2.12 m/s

<

4.330 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 1500mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(1800mm R.C. Drain) - Drain 35c


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area [A(D35b),A(D29),A(D31),A(D21-24),A35c]
2
205666 m

Where:

Q1

=
=
=
=

3
6.170 m /s

b) Capacity for Sub-catchment drain


Drain Size
=

1800 mm

Drain top level, DTL =

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

1.63 m
1.8 m
125 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
1.48 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

2.664
4.76
0.560
1/500
0.013

Qcap

6.224 m3/s

Velocity, v

=
=

Where:

m2
m
m
(For R.C. Drain)
>

Qcap/A
2.34 m/s

<

6.170 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 1800mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet

Rev.

(2000mm R.C. Drain) - Drain 35d


Client :

CALCULATION SHEET

SV
Checked by: HIL
Made by:

Date:
Date:

Description

Reference

a) Surface runoff
Qi

CsC I A

Qi
C

=
=
=
=
=
=
=

the peak discharge in cubic meter per second


the coefficient runoff for residential & commercial
development area
0.9
Storage coefficient
1
the average intensive of rainfall120mm/hr (average)
3.33333E-05 m/s
largest catchment area (+2A21,3A22,A23,7A24)
2
92161 m

Q35c + Q29 + Q31

Where:

b) Capacity for Sub-catchment drain


Drain Size
=

2.15 m

Depth (D)
Width (W)
Length (L)

=
=
=

1.35 m
2m
125 m

Freeboard
=
Allow' water depth =
=

0.15 m
D - Freeboard
1.2 m

A R

Qcap

A
P
R
S
n

=
=
=
=
=

2.4
4.4
0.545
1/500
0.013

Qcap

5.512 m3/s

Velocity, v

=
=

Where:

0.000

m3/s

2000 mm

Drain top level, DTL =

m2
m
m
(For R.C. Drain)
>

Qcap/A
2.30 m/s

<

0.000 m3/s

OK

3 m/s

OK

Varies
Freeboard
= 0.15m

11/20/2014
11/20/2014
Result

1.0 Calculation for capacity of 2000mm R.C Drain

Cs
I

Job Title:Tudan Housing


Subject: Drainage Design Analysis

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet
9
Rev.
MLNG Fire Fighting Training Centre, Bintulu

Job Title:
Subject:

Drainage Design Analysis


Date: 30.10.08

FJ
Checked by: CCL

Client : MLNG S/B Made by:

CALCULATION SHEET

Date: 30.10.08

Description

Reference

Result

Calculation for capacity of the existing 300~400 mm R.C Drain


Q

AR

n
1.0 Point A
Q

0.30 x 0.10(2/3) x (1/250)1/2


0.013
3
0.094
m /s

=
=

0.30

0.3
2.0 Point B
0.30
Q

0.30 x 0.10(2/3) x (1/250)1/2


0.013
0.094
m3/s

=
=

0.3

3.0 Point C
0.30
Q

0.30 x 0.10(2/3) x (1/250)1/2


0.013
0.094
m3/s

=
=

0.3

4.0 Point D
Q

0.40 x 0.12(2/3) x (1/250)1/2


0.013
0.142
m3/s

=
=

0.30

0.4
5.0 Point E
Q

0.40 x 0.148(2/3) x (1/250)1/2


0.013
0.310
m3/s

=
=

0.57

0.4
Surface runoff from Drain 1-2-3-4-5
Q

=
=

(0.90 x 2.97 x 10-5 x 841) + (0.75 x 2.97 x 10-5 x 650)


m3/s
0.050

Q Drain at point E = 0.310 m3/s > Q surface run-off from drain 1-2-3-4-5 = 0.050 m3/s

OK

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet
10
Rev.
MLNG Fire Fighting Training Centre, Bintulu

Job Title:
Subject:

Drainage Design Analysis


Date: 30.10.08

FJ
Checked by: CCL

Client : MLNG S/B Made by:

CALCULATION SHEET

Date: 30.10.08

Description

Reference

Result

Calculation for capacity of the existing 300~400 mm R.C Drain


6.0 Point F
Q

=
=

(2/3)

0.40 x 0.163
x (1/250)
0.013
3
0.504
m /s

1/2

0.87

0.4
7.0 Point G
Q

=
=

0.40 x 0.163(2/3) x (1/250)1/2


0.013
0.504
m3/s

0.87

0.4
8.0 Point H
Q

=
=

0.40 x 0.163(2/3) x (1/250)1/2


0.013
0.504
m3/s

0.87

0.4
9.0 Point H1
Q

=
=

0.40 x 0.163(2/3) x (1/250)1/2


0.013
0.504
m3/s

0.87

0.4
Surface runoff from Drain 17-18-19-20
(0.90 x 2.97 x 10-5 x 554) + (0.75 x 2.97 x 10-5 x 441)
Q
=
m3/s
=
0.025
Q(21-22-23-25-19) & Q(23-24-20)
Total Q

= 0.104 + 0.098
=
=

0.025 + 0.202
0.227

m3/sec

0.202

m3/sec

Q Drain at point H1 = 0.504 m3/s > Q surface run-off from drain 17-18-19-20 = 0.227 m3/s

OK

10.0 Point H2
Q

=
=

0.40 x 0.163(2/3) x (1/250)1/2


0.013
0.504
m3/s

0.87

0.4
Surface runoff from Drain 12-13-14-15-16
(0.90 x 2.97 x 10-5 x 841) + (0.75 x 2.97 x 10-5 x 650)
Q
=
m3/s
=
0.037
Q from Fire Fighting training:
Q (Kerosene-fire training modules)
Total Q

=
=

=
0.037 + 0.083
0.120

300 m3/hr

0.083

m3/sec

m3/sec

Q Drain at point H2 = 0.504 m3/s > Q surface run-off from drain 12-13-14-15-16 = 0.120 m3/s

OK

Jurutera Perunding Akal Sdn Bhd


Consulting Engineers (400046-X)

JPA No.

Lot 1386, Jln Kubu, Miri Centre Point Phase 2, 98000 Miri, Sarawak
Tel : 085-438178 Fax: 085-438196
Email : jpasb@akal-epmc.com..my

JPA/P-063 Sheet
11
Rev.
MLNG Fire Fighting Training Centre, Bintulu

Job Title:
Subject:

Drainage Design Analysis


Date: 30.10.08

FJ
Checked by: CCL

Client : MLNG S/B Made by:

CALCULATION SHEET

Date: 30.10.08

Description

Reference

Result

Calculation for capacity of the existing 300~400 mm R.C Drain


Point I
Q

=
=

0.60 x 0.231

(2/3)

1/2

x (1/350)
0.013
3
0.504
m /s

0.87

0.4
Point J
Q

=
=

0.60 x 0.231(2/3) x (1/350)1/2


0.013
0.504
m3/s

0.87

0.4

You might also like