You are on page 1of 16

SCRF-300CA-16L

MD024042080X

A B C D E


4M
,

OK NG

11 514

11 514

11 514

11 514

11 514

11 514

TEL0752-5199852

FAX:5199837

38
1 14


:SCRF-300CA-16L

:MD024042080X

2 14

ProductionSpecification

1. Measurement condition

1-1 Motor Position

1-2 Power Supply

1-3 Environmental Temperature

Motor to be held, with shaft horizontally

Regulated power supply which assures unquestionable measurement.


.
The test is made in principle of a temperature between 10 to 30

And Humidity

And at relative humidity between 30% and 95%, If the test result

is questionable, it shall be judged from the tes made at JIS Standard


Testing Condition (202,60%-70%RH).
10-3030%-95%
JIS(202,60%-70%RH).

2. Standard Operating Conditions

2-1 Rated voltage

4.5V DC CONSTANT between motor terminals

2-2 Operating voltage range

2-3 Rated load

2-4 Direction of rotation

2-5 Rang of operating

4.5V DC
1.0V-6.0V DC CONSTANT between motor terminals
1.0V-6.0V
0.392 mN*m by pulley load
0.392 mN*m4.0g*cm
CW & CCW

-10 +60

tempersture

2-6 Storage Temperature Range

-40 +80

3 14

ProductionSpecification

3. Electrical specification
3-1 NO Load Current

40mA MAX

3-2 NO Load speed

5000500r/min

3-3 Rated Load Current

110mA MAX

3-4 Rated Load Speed

4300450r/min

3-5 Starting Torque

2.352mN*m(24g*cm)MIN Rated Voltage based on measurement


at two different Load(0g* and 4g*)
2.352mN*m(24g*cm)MIN,0g*4g*

3-6 Starting Current

450mA MAX

3-7 Starting voltage

1.0V MAX

3-8 Insulation resistance

DC 100V 1.0 MIN

3-9 Current Waveform

3-10 Electrical noise

3-11 Rotor resistance

At 1.5V DC and no load.Free from off point


1.5V,
Motor to be equipped with varistor

10.04-11.56

4 14

ProductionSpecification

4. External & Functional Characteristics


4-1 Shaft End Play

0.02-0.2mm

4-2 Weights

Approx 21g

4-3 Mechanical Noise

40dB-A MAX

2.0V voltage, no load, and motor horizontally held, measured by JIS-A


(RMS),at 10cm away from metal housing on protruded side, and back ground
noise to be 36dB(max),clearance noise when if disappear with 50g radial force
onto shaft to be excluded.
40dB-A
2.0V(JIS-A(RMS)
50g
36dB-A.

10mm

MIC

4-4 Maximum Axial Load

MOTOR

Direction of static load and support of measured by JIS-A(RMS),

at 10cm away from metal housing


196N MIN

Staticload
Support of the load

4-4 Perpendicularity of

90 14'

output shaft

4-5 Intruduction of power

1.0kgf

Brush terminal

5 14

ProductionSpecification

5. Environmental Tests
5-1 Vibration Test

All of the specifications in Item 3 and 4 are to be satisfied after


motor is subjected to the sine wave of 2 mm amplitude and 16.7 Hz
in the three directions for 2 hours minutes each.
XYZ2 mm,16.7 Hz
2,34.

5-2 Shock Test

All of the specifications in Item 3 and 4 are to be satisfied after


motors Picked in the dilivery tray, all faces at 1 time from a height
of 30cm on a 10cm wood black.
10cm30cm6
,34.

5-3 Storage Test under

All of the specifications in Item 3 and 4 are to be satisfied after

high temperature

motors exposed to +85for 240 hours, and then to temperature

humidity of Item 2-3 for 24hours.


+8524024
34.

5-4 Storage Test under

All of the specifications in Item 3 and 4 are to be satisfied after

low temperature

motors exposed to 40 for 240 hours, and then to temperature

humidity of Item 2-3 for 24 hours.


40240
2434.

5-5 Storage Test under

All of the specifications in Item 3 and 4 are to high be satisfied

temperature

after motors exposed to +6090%-95% RH for240 hours, and

humidity

then to temperaturehumidity of Item 2-3 for 24 hours.

+6090%-95%240
2434

6 14

ProductionSpecification

5. Environmental Tests
5-6 Cold And Hot Impact

Temperation 85 Storage for 30Minute Temperation -40 Storage for


30Minute100Hypo Measurement 24 Hrs At room temperature and normal
humidity. Rated load speed varies & current varies within 30% from the initial.

8530-4030100
24.
30%.

6. Life test
6-1 Ambient temperature

Environ mental condition:255/65%20%RH,4g-cm load,cycle

Intermittent

condition as below. 100000 cycles min.

:255/65%20%RH
4 g-cm .. 100000 .

6-2 Hight temperature

Environ mental condition: +60

Intermittent

4g-cm load,cycle condition as below.50000 cycles min

4g-cm .. 50000 .
2s

+2.0v
+4.5V

2s

0v

-2.0v
-4.5V

2s

2s

1 cycle

Before/Afterlifetest,measuringtheratedloadspecification.Motor life is
judged to come to an end when.
,,.
1:Rated load speed gets varied over15% against the initial figure.
15%.
2:Rated load current gets varied over +35% against the initial figure.
+35%
3:motor is unquestionable recognized as unusable.
.

7 14

ProductionSpecification

7. Rejects
Motors which do not meet with the specifications mentioned above or which are apparently judged
as faulty due to poor workman ship.
,

8. Others
1:Label means:

Star China Label /


SCRF-300CA-16L
D/V 4.5

Motor type /
Rated voltage /

B109101
B1 Line number /
09 Year / 2009
1 Month / 123 9XYZ
01 Daty / 123 3031

2:When machine material and method are changed, customers will be notified in advance.
.

8 14

ProductionSpecification

9. Environment-related substance
The part should not contain any environment-related substance.
.
The details of use prohibition parts or exclusion items as below.
.

(1) Heavy metals


Cadmium and its compounds(Cd)

Lead and its compounds(Pb)

Mercury and its compounds(Hg)

Hexavalent chromium compounds(Cr+6)

(2) Chlorinated organic compounds

Polychlorinated biphenyls(PCB)

Polychlorinated naphthalenes(PCN)

Chlorinated paraffins(CP)

Other chlorinated organic compounds

(3)Brominatedorganiccompounds

Polybrominated biphenyls(PBB)

Polybrominated diphenylethers(PBDE)

Other brominated organic compounds

(4) Organic tin compounds

(5) Asbestos

(6) Azo compounds


(7) Formaldehyde
(8) Polyvinyl chloride(PVC) and PVC blends

9 14

ProductionSpecification

10.Packing

Nume

Size()

Motor()

Amount()/Box
100

Paper Box()

380295180

Plastic Cover(

37028024

Plastic Box()

37028024

Summation ()

800 pcs

(1) Foam Box ()

(2) 100 Pcs 8 = 800 Pcs

(3) Paper Box ()

10 14

ProductionSpecification

11. Precautions in using the motor

(1) If silicon materials, which contain low molecular silicon compounds,adhere to the motors commutator,
brush or other parts,then upon rectification of the electric energy the silicon breaks down into SiO2,SiC and
other constituents which produce a rapid increase in the contact resistance between the commutator and brush.
There fore great care should be taken when silicon material is used in a unit and check well at the same time
that such binding agents or sealing materials are not generating gases of detrimental nature, whether used for
motor mounting or applied during your product assembles. Care must be taken for an optimum selection ,
especially when using those of cyanicadhesive and sulfur gas.
Si, S,

(2) When mounting your motors by means of binding agents, DONT allow any adherence to the bearings
nor intrusion into the motors.
.
(3)Axial thrust on the output shaft could have an adverse effect on the motor life .i.e. As is produced by worm
gears,fans,etc.Check the service life expected under the actual operating conditions by testing the motors
installed in your application products. For heavy thrust loads, consider using something mechanical to retain
the shaft end.

(4)There are occasions when the internal resistance of the motor driving power source (Which contains an
electrical circuit) can influence the life span of the motor. In instances where there is a low input of voltage to
the motor, the internal resistance of the power source is large which may well result in an inferior motor after a
short time, conversely in instances where high cyclic voltages are applied, this internal resistance is small and
the motor life span is shortened. When the temperature dviates from the normal room temperature as is the
case in low and high temperature situations, please note the conditions.

.
(5)Motor life may be affected adversely by heavy radial load such as produced by rotating eccentric carns,etc.,
and also by vibration given from outside. Do check over such negative factors by testing the motors to the
actual operating conditions in your application products.
.
(6)If when mounting the motor and assembing the unit, equipment which emits ultrasonic waves is used there is
a danger that some of the internal parts of the motor might be damaged so please take care.
.

11 14

ProductionSpecification

11. Precautions in using the motor

(7)DONT store motors under environmental conditions of high temperature and extreme humidity. DON
T keep them also in an atmosphere where corrosive gas may be present as it may result in malfunetion.
.
(8)Ambient and operating temperatures exert an affect more or less on motor performance and life. Do pay
particular attention the surroundings when it is hot and damp.
.
(9)When press fitting a pulley , gear etc., onto the motor output shaft, always support the shaft at the other end or
its retaining metal pad in a proper and correct way.
.
(10)When soldering, BE SURE to finish your work quickly so as not to develop plastic deformation around the
motor terminals nor to give them any forced bend or inward depression. In doing so, special care must be
taken not to allow solder debris and flux to spatter into motors and precautionary measures should be taken if
necessary by covering up all the nearby holes and apertures. Any motors having snap-in terminals must also
be attended carefully so as not to get flux in along the terminals, as it may cause failure in electrical
conduction.

.
.
(11)DONT leave motor shaft locked while power is applied , as even a short-time lock-up may cause excess
heat build up resulting damage to the motor depending on its specifications.
.
(12)Intensive pressure on the endbell boss might cause starting disability of motor.So please take care for motor
mounting not to push endbell boss. If the endbell boss must be pushed,the load should be put on the center of
the boss. Please ask us for the suitable value of the load.
.
. .
(13)Please do not touch motor bearing as otherwise bearing oil will be drawn out, which might cause
bearing noise.
.
(14)When motor more than three months did not be used for need to note oil for bearings and confirm afresh.
.

12 14

ProductionSpecification

11. Precautions in using the motor

(15)Fumigant and its gas may affect motor performance.Then, motors shall not be eaposed to fumigand and its
gas, if fumigation shall be made for packaging material etc.
. .
.
(16)Identification marking drawn on motor housing with dyestuff marker may be blurred or may fade
out when rubbing.
.

For more information, please contact us directly or through our sales and representative offices.
.

13 14

ProductionSpecification

12. Motor Characteristics Curves

14 14

You might also like