DC MOTOR/PUMP CAPABILITIES GUIDE

HYDRAULIC SYSTEMS DIVISION

Outstanding Hydraulic Products, Service and Expertise, Worldwide

TABLE OF CONTENTS

INNOVATORS IN D.C. MOTOR/PUMP TECHNOLOGY --------------------------------------------------- 3


Motor Features ------------------------------------------------------------------------------------------------------- 4
Pump Features ---------------------------------------------------------------------------------------------------- 5 - 6

PRODUCT / FEATURE MATRIX --------------------------------------------------------------------------------- 7

AERIAL LIFT MARKET


Boom Lifts (Auxiliary Power Units) ------------------------------------------------------------------------- 8 - 15
Scissor / Boom Lifts (Lift / Propel / Steer) ---------------------------------------------------------------- 16 - 22

MATERIAL HANDLING MARKET


Pallet Trucks (Lift) -------------------------------------------------------------------------------------------- 23 - 25
Stacker Trucks (Lift) ------------------------------------------------------------------------------------------ 26 - 27
3-Wheel Sit Down Trucks (Power Steering)------------------------------------------------------------- 28 - 32

CONSTRUCTION MARKET
Various (Power Steering) ----------------------------------------------------------------------------------- 33 - 40

Pictures on front cover are used with the kind permission of eg: Atlet, BT, Huddig, Scania, Toro and Volvo Construction Equipment.

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

INNOVATORS IN D.C. MOTOR/PUMP TECHNOLOGY


A Haldex D.C. motor/hydraulic pump assembies are compact, versatile hydraulic
power systems which include a pump and
a D.C. motor. Numerous control valves can
be incorporated in the basic packages to
meet a wide variety of system requirements.
These systems are typically applied in mobile applications where a common reservoir
is accessible.
Haldex expertise in designing, applying
and producing D.C. motor/hydraulic pump
assemblies is highly regarded within the
industries that we serve. We are considered a source of knowledge in this area by
the material handling industry, aerial lift
industry and the construction equipment
industry, among others.

Aerial Lift Industry


The Aerial Lift Industry also relies on
Haldex long history of success in applying D.C. motor/pump assemblies for its
equipment. Our systems are well suited
for auxiliary / secondary lowering requirements for off-highway vehicles, lift
platforms, or boom applications where
the primary hydraulic source becomes
nonfunctional or unavailable. They may
also be used for minor jib or basket
adjustments by the operator.
These motor/pump units are also designed for scissor and boom lift vehicles
as the primary power source. These
units provide hydraulic power to propel,
raise and steer the vehicles.

Material Handling Industry

Construction Industry

The Material Handling Industry relies on


Haldex knowledge and experience for
applications such as lift, tilt, power steering and auxiliary functions on many types
of industrial lift trucks. These motor/pump
units can be designed for pallet trucks that
require separate motor, pump and reservoir
packages. These units provide primary
hydraulic power for lifting and other functions.

In the Construction Equipment Industry,


we are called upon for assistance with
traction drive applications as well as the
lift functions for aerial devices.

They can also be designed for high reach


stackers that require separate motor, pump
and reservoir packages as well. They
provide primary hydraulic power for lifting
and, under certain applications, can provide
secondary power for fork carriage extension
or side-to-side shift operation.
Narrow aisle or 3-wheel sit down forklifts
also typically require separate motor/pump
and reservoir packages. These units provide
primary hydraulic power for lifting and vehicle steering along with secondary power
for fork carriage extension or side-to-side
shift operation.

Also, many construction machines


require a supplemental source of hydraulic power when the primary source
becomes nonfunctional or unavailable.
Examples of these include large hoists,
cranes and wheel loaders. Haldex D.C.
motor/hydraulic pump assemblies are
ideally suited to meet these needs.

The mating of a D.C. motor and hydraulic


pump into an assembly and the application of these assemblies is dependent on
a diverse set of variables. Each application
varies in complexity. Complete knowledge
of the unique characteristics of individual
D.C. motors is essential and, of course,
expert knowledge of individual hydraulic
pump performance is necessary. But the
merging of D.C. motors and hydraulic
pumps is a technology all its own. And, it
is in this area that Haldex excels.

Why Specify Haldex?


Specifying a complete D.C. motor/hydraulic pump assembly ensures system
reliability. All Haldex D.C. motor/pump
assemblies are tested for proper coupling
engagement, balance motor armature,
amp. draw at rated voltage and ow at
specied pressure.

The Intent of this Catalog . . .


This catalog draws on our extensive experience to illustrate the range of Haldex
D.C. motor/hydraulic pump capabilities.
Included are performance curves and
dimensional drawings. This catalog will
present various types of D.C. motors available and the extensive selection of Haldex
pumps available to be applied with them.

Haldex D.C. motor construction is also


well suited for applications in off-highway equipment where the conditions
are harsh and rugged performance is
required. For example, power units can
be constructed with heavy duty start
switches and insulated wiring boots.

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

MOTOR FEATURES OFFERED


MOTORS . . .

Series Wound Field

Haldex offers an extensive range of D.C.


motors from 12 to 48 volts. The two motor
designs that are incorporated in the majority of our applications are the permanent
magnet type and the wound eld type.
Under these broad categories, there are
numerous combinations of voltages, frame
sizes and duty ratings available.

In Series-Wound Field motors, the excitation


and armature windings are both electrically operated with the current passing
through the armature. Series Wound motors, therefore, develop high initial torque
which decreases sharply as the motor speed
increases.
Armature
Wound Field

Permanent Magnet

Armature
PM Field

Series Wound Field D.C. Motors


Speed (RPM) / Current (Amperes)

Motors with permanent magnet excitation are characterized by simple design.


Because the magnetic eld is created by
permanent magnets, excitation of the motor is constant under all operating conditions. The speed variation vs. torque will
remain relatively consistent over the motors
operating range.

t
ren

Cur

Spe

ed

Typical Series Motor


Performance Curves

Speed (RPM) / Current (Amperes)

Permanent Magnet D.C. Motors

n
rre

Cu

Torque (Pound Feet)

Typical PM Motor
Performance Curves
Permanent magnet motors generally run at
a nominal speed of 1800 RPM (although
other speeds are available). These motors
have a lower stall torque than wound eld
motors, but are more efcient and exhibit
superior thermal characteristics which make
them more suitable for continuous duty
applications. Some of the most common
applications of permanent magnet motors
are power steering and fuel systems.

Voltage
Haldex offers a full range of D.C. motor
capabilities from 12 to 48 volts.

Single or Double Terminal


Haldex offers single terminal motors where
the motor is internally grounded. Cost
savings is achieved by eliminating additional
wiring. We also offer double terminal motors where an external ground is required.

Several Sizes and


Construction

Torque (Pound Feet)

Speed

Listed below are the standard features available on Haldex D.C. motors. A brief explanation of these features is also included for
each section.

Wound eld motors are higher speed motors which exhibit a very high stall torque.
Their thermal characteristics are such that
they can generate higher power levels for
short periods of time. Wound eld motors
are available with different duty ratings. At
Haldex these motors are classied as standard duty (usually single terminal motor,
totally enclosed non-ventilated (TENV), with
sleeve type bearing and 4 inch diameter),
medium duty (usually has ball bearing
in rear housing, U.L. approved, totally
enclosed non-ventilated (TENV), 4 inch
diameter motor and duty cycle is somewhat
longer than standard depending on application) and heavy duty (usually 2 terminal,
5 inch diameter motor, open ventilated
fan cooled (OVFC), exhibiting longer duty
cycles, depending on application).
The above are distinguished by motor
diameter or frame size, and the ability to
dissipate heat at different current levels over
a specic time interval. In general, wound
eld motors are used in applications where
the loads are higher and greater speed is
required but only on an intermittent basis.
Wound eld motors are load sensitive and
speed will vary with the applied load; performance curves are required to determine
the output at a given point. Applications
include lift functions on aerial devices and
material handling equipment as well as
auxiliary power steering on construction
equipment.
HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

We offer the standard 4 inch diameter


motors as well as 3 and 5 inch diameter.
Available features include open drip proof,
thermal protection and sealed designs.

Start Switches
Haldex offers start switches which can be
mounted in a variety of locations to suit
your applications. We offer 3 terminal and
4 terminal (U.L.) switches in heavy duty
designs, with or without boots.

Various Mounts
Haldex offers a number of standard motor
mounting brackets and will work to meet
your specic mounting requirements.
Shown here are foot mounts, pump/stator
mounts, and horseshoe mounts.

U.L. Approval
Haldex can provide Direct Current electric
motors intended for use in the electric battery powered industrial truck market. These
motors are intended to comply with the
requirements of UL 583 for Type E, ES or EE
industrial trucks.

PUMP FEATURES OFFERED


PUMPS . . .
The Haldex line of high quality cast
iron and aluminum bodied gear pumps
range in size from .065 in.3/rev. to 2.40
in.3/rev. (1.06 to 39.32 cc) displacements. The two pump styles offered
are xed clearance and pressure balanced. These two pump styles differ in
design and in the volumetric efciency
they exhibit under various conditions.

To reduce the leakage between the gear


face and the housing, the pressure balanced
design has been developed. This design
incorporates oating bearing blocks in the
pump housing on the sides of the gear faces. As pressure is developed by resistance
to the pumps ow, it creates a hydraulic
force which tends to push the bearing
blocks away from the gear faces. However,
this force is balanced by an opposite pressure which is applied on the opposite side
of the block via a port behind the block. As
the pressure level increases, the opposite
pressure on the block increases to insure
that the clearance between the bearing
block and the gear face is the smallest possible without creating excess friction which
would effect the mechanical efciency of
the pump. Pressure balanced pumps are
well suited for applications where lower viscosity uids, higher temperatures, or higher
pressures and duty cycles are encountered.

Volumetric efciency is the actual


ow a pump produces relative to the
theoretical (or maximum) ow it could
produce if it had no internal losses.
The two major leak paths that determine volumetric efciency in a gear
pump are between the gear tips and
the housing, and between the gear
faces and the housing. Reducing the
leakage over the gear tips is a function
of being able to hold component parts
to precise and exacting tolerances.
We have demonstrated over many
years that we have the equipment and
expertise to consistently provide the
required precision in the fabrication
of the components used in our gear
pumps.

Choosing a Pump . . .
Choosing the type of pump is determined
by a number of factors that are interrelated. The system pressure requirement
may completely dictate the type of pump
required and the motor may have to be
sized accordingly. When the selection of a
pump type is not dictated, overall efciency
(as it relates to choosing the most economical D.C. motor and the cost of operating
the vehicle) must be considered. In many
cases, where high pressure, high duty cycle
or low viscosity uid are not factors, a xed
clearance pump is the most economical
design to use. These units are less expensive, and their volumetric efciencies at low
to moderate pressures are comparable to
pressure balanced pumps.

In applications where xed clearance pump


efciency is not adequate, the pressure
balanced design may be desired because
of the higher volumetric efciency. Higher
volumetric efciency on the pump side typically results in faster machine cycle speeds.
Cycle speed is important in most battery
powered mobile equipment applications
because battery life is rated in amp./hours.
The less time that amps are being drawn
from a battery pack, the longer the battery
pack will last before recharge or replacement. In most applications, overall efciency of pressure balanced pumps is higher
than that of xed clearance pumps. The
understanding of how the overall efciency
of a pump varies based on different application parameters is critical to the selection
of the optimum D.C. motor for a specic
motor/pump application. Haldex has many
years of experience in this area.

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

PUMP FEATURES OFFERED


Listed below are the standard features available on Haldex pumps. A brief explanation
of these features is also included.

(Cont.)

Adjustable Relief Valve

Tang Drive System

Haldex external gear pumps are available


with integral adjustable relief valves. Tamper proof versions are also available.

A .171 wide tang for GC pumps and a


.244 wide tang for PB (Pressure Balanced)
pumps are the most durable standard tang
drives offered. These wider tangs provide
greater tang / shaft engagement, thereby
reducing the play between the shaft and
tang. Reduced play results in reduced wear
of the tang during motor starts and longer
drive system life.

GC Series
Fixed Clearance Pumps

Check Valve

Haldex GC Series hydraulic pumps are highefciency cast iron gear pumps designed for
reliability and long-life performance under
rugged conditions. GC Series pumps are
built with cast iron bodies and hardened
steel gears. They are suitable for use in a
wide variety of
applications.

Solenoid L-H-L Valve

W Series
Pressure Balanced Pumps
The pressure balanced W Series hydraulic
pump offers outstanding performance,
exibility, high efciency, low noise performance and a variety of options to suit a
wide range of equipment needs. It features
a through-bore bushing type design construction.

Split Gear Pumps


A Split Gear pump incorporates two gears
offset by one tooth to obtain the desired
displacement. By offsetting the teeth of the
gears, the number of pressure pulses is increased and the magnitude of these pulses
is decreased; therefore, reducing any noise
caused by the pump.

Multiple Pumps
Multiple pumps provide multiple hydraulic
functions from one power source at a signicantly lower cost than separate pumps.
Some can also be sealed between sections
to allow for independent circuit operation
without mixing hydraulic uids.

High/Low Pumps
Two-Stage High/Low pumps provide two
section ow for high speed positioning, and
unload one section of the pump at a predetermined pressure to provide a maximum
working pressure.

Pressure Balanced Pumps


This design incorporates oating bearing
blocks in the pump housing on the sides of
the gear faces. As pressure is developed
by the pump, it creates a hydraulic force
which tends to push the bearing blocks
away from the gear faces. However, this
hydraulic force is balanced by an opposite
pressure which is applied on the block via
a port behind the block. As the pressure
level increases, the opposite pressure on the
block increases to insure that the clearance
between the bearing block and the gear
face is at the smallest possible increment
without creating excess friction which would
decrease the mechanical efciency of the pump.

Haldex external gear pumps can incorporate integral check valves. All Haldex check
valves feature hardened steel seats.

Haldex external gear pumps can incorporate lift-hold-lower valve circuits, integral to
the pump housing and electronically actuated by either a 12, 24, 36 or 48 volt D.C.
UL approved coils.

Unload Valve
Haldex external gear pumps can be designed with an unload valve to optimize
system performance and vehicle operation.

Extended Duty
Tang Drive System
For higher duty cycle or high torque applications, we have developed the Haldex
extended duty tang drive. This innovative
drive reduces axial play between tang and
shaft to a minimum by means of a wave
washer placed behind the ball bearing on
the shaft. This washer keeps a constant
spring load on the shaft to ensure maximum tang engagement at all times.

Solenoid w/Manual Override


The solenoid actuated valve option can
include a manual override feature to allow
for manual actuation of the valve.

Load Sense Valve


Load Sensing is a hydraulic circuit conguration which allows the load, as sensed at
the control valve, to modulate pump output
in relation to system demand. Controlling
both ow and pressure at the pump allows
for a signicant reduction in valving losses
and circuit inefciencies. This provides
many of the operational benets of a piston
pump with the performance, reliability and
cost advantages of a gear pump.

SAE Side/Rear Ports


Haldex standard porting is SAE (Straight
Thread O-Ring) side ports. This type of port
offers greater resistance to leakage and
is more serviceable than other port styles.
SAE rear ports are also available.

Inlet Tubes
Oversized inlet tubes are available on
Haldex pumps to ensure proper ll and uid
inlet conditions.

Drive Systems . . .
The other critical element to be considered
when specifying a D.C. motor/pump unit
for your application is the drive system.
Drive system failure is known to be a
signicant problem in many D.C. motor/
pump applications today. Haldex has both
the product and a wealth of application
expertise in this area to ensure that your
D.C. motor/pump unit incorporates the
correct drive system for your application
requirements. The following descriptions
dene the four (4) drive systems available
for Haldex D.C. motor/pump units.
HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

Flexible Coupling
Drive System
This drive system eliminates all metal to
metal contact by means of a rubber spider
which engages inside two metal coupling
housings. The material Haldex has selected
for its exible drive coupling exhibits superior resistance to deformation and wear. This
system provides maximum torque transfer
and quiet operation and is primarily used
for continuous duty applications.

SAE 9 Tooth Spline


Drive System
This drive system allows for direct pump/
motor spline connection to distribute higher
torque and duty cycle operation with lower
noise levels emitted from the pump/motor
combination.

PRODUCT/FEATURE MATRIX
Numbers represent page numbers
in this catalog where you can nd
examples of your desired product
features for your market, vehicle
and application.

Market
Vehicle

Aerial Lift

Application

Boom

Scissors/
Boom

Pallet/
Stacker

3-Wheel
Sit Down

Various

APU

Lift/
Propel/
Steer

Lift

Power
Steering

Power
Steering

24
25,27

30
29,31
32
32

Product Features
Motors

Voltage

Terminals

Design

9,10,11,12,13,15
14

Single
Double

9,10
11,12,13,14,15

17,18,19,20,21,22

24,25,27

29,30,31,32

34,35,36,37,38,39,40

Permanent Magnet
Wound Field

9,10,11,12,13,14,15

20,21
17,18,19,22

24,25,27

32
29,30,31

34,35,36,37,38,39,40

17,18,19,20,21,22

24,25
27

17,18,19,21,22
20

9,10,15
11,12,13,14

Standard 4.5
3
5
Open Drip Proof
Sealed
Thermal Protection

9,10,11,12,13,14
15

Approvals

UL

11,12,13,14,15

Start Switch

3 Terminal
4 Terminal (UL)

10
12,13,14

Construction

Controls

12
24
36
48

Low
Medium
Extended
Continuous

Duty Cycle

Pumps

Sections

29,30,31
32

34,35,36,37,38,39,40

17,18,19,22
17,18,19,21,22
20
20

27
27

29,30,31,32
29,30,31,32

34,35,36,37,38,39,40

17,18,19,22

24,25,27

34,35,36,37,38,39,40
29,30,31

24,25,27
27
25,27

34,36,37,40
36,37,40
37,40
36

13
15
9,10,11,12

17,18,19,20,21,22

GC
Split Gear
W600
W900
High/Low
Pressure Balanced

9,10,11,12,13,14,15

17,18,19,20,21,22

Single
Multiple

9,10,11,12,13,14,15

17,18
19,20,21,22

24,25,27

29,30,31,32

34,35,36,37,38,40
39
39

Relief Valve
Check Valve
Solenoid L-H-L
Unload
Solenoid w/Man. Override
Sol. Vlv Cavity w/Steel Plug
Load Sense

9,10,11,12,13,14,15
9,10,11,12,13,14

21
21

24,25,27
25,27
27

30,31,32
30,31

34,37

Tang
Direct Drive Tang
Flex Coupling
SAE 9 Tooth Spline

9,10,11,12,13,14
15

Side
Rear
Inlet Tube

9,10,11,12,13,14,15

Foot Mount
Pump/Stator
Horseshoe
Type

25,27

29,30,31,32

Shafts

Ports

34,35,36,37,38,39,40

24
24,25,27

29,30
32
34
35,36,37,38,39,40
31

Sealed
Between
Sections
Valves

34,35,36,37,38,39,40

24,25

Heavy Duty
10
w/Boots
12,13,14
w/o Boots

Mounting

Material Handling Construction

21
31

14

38,39,40
24,25,27
17
18,19,20,21,22

29,30,31
32
34,35,36,37,38,39,40

17,18,19,20,21,22

24,25,27

29,30,31,32

34,36,37,38,39,40
35

29,32

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

BOOM LIFTS
Secondary Lowering
Auxiliary Power Units

These pump and motor power units are designed for applications requiring auxiliary hydraulic power. Typical applications are for truck, mobile crane and boom equipment. These power units are
well suited for auxiliary / secondary lowering requirements for off-highway vehicles, lift platforms,
or boom applications when the primary hydraulic source becomes disabled or nonfunctional. They
may also be used for minor positioning adjustments by the operator.
Unit complexity can range from a simple pump and motor unit without any valving, to units that incorporate pressure holding check valves and over-pressurization protecting relief valves. Units range
in size from light duty 3 inch motors to medium duty 4.5 inch motors.

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

Motor:

12 Volt DC, 1 Terminal, Wound Field, Low Duty, Standard 4.5 Motor, No Start
Switch, with Horseshoe Mounting

Pump:

GC Series Pump, Single Section, Relief Valve, Check Valve, Tang Drive

NOTE: Dimensions are inches [mm].


M

ROTATION
1.88
[47.75]

TERMINAL POST
5/16-24 UNF-2A

HYDRAULIC SCHEMATIC

INLET PORT
3/4-16 SAE
(THIS SIDE)

ADJ. RELIEF VALVE

OUTLET PORT
9/16-18 SAE
(OPPOSITE SIDE)

CHECK
VALVE

4.49 [114.04]
C PORTS
L
C DRIVE
L
.50 [12.7]
2.50 [63.5]

.42
[10.41]

6.83
[173.48]

2.84
[72.13]

1.63
[41.40]
2.25
[57.15]

10.55
[267.97]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

4.50
[114.3]

3.25
[82.55]

3/8-16
UNC
.625
[15.87]
MFD
2 MTG
HOLES

Motor:

12 Volt DC, 1 Terminal, Wound Field, Low Duty, Standard 4.5 Motor, 3 Terminal
Start Switch with Boots, and Horseshoe Mounting

Pump:

GC Series Pump, Single Section, Relief Valve, Check Valve, Tang Drive

NOTE: Dimensions are inches [mm].

HYDRAULIC SCHEMATIC

ROTATION
.91
[23.11]

10.35
4.33
[262.89]
[109.98]
5/16-24 UNF-2A TERMINAL

#10-32 UNF-2A

CHECK VALVE

2X
5/16-24
UNF-2A

4.01 [101.85]
4.49
[114.04]

C MOTOR
L
C PORTS
L
.50
[12.7]

6.65
[168.91]

10

ADJ.
RELIEF
VALVE

.42
[10.66]

2.50 [63.5]

2.41
[61.24]
THIS SIDE

9/16-18 SAE
OUTLET PORT
(THIS SIDE)

2.54
[64.51]
OPPOSITE
SIDE

3/4-16 SAE
INLET PORT
(OPPOSITE SIDE)

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

1.63
[41.40]
2X
3/8-16 UNC
X .625 [15.87] M.F.T.

3.25
[82.55]

2.25
[57.15]

Motor:

12 Volt DC, 2 Terminal, Wound Field, Medium Duty, Standard 4.5 Motor,
UL Approved, No Start Switch, with Horseshoe Mounting

Pump:

GC Series Pump, Single Section, Relief Valve, Check Valve, Tang Drive

NOTE: Dimensions are inches [mm].


HYDRAULIC SCHEMATIC

ROTATION

5/16-24
UNF-2A

CHECK VALVE

PORTS

2.53
[64.26]
.50 [12.7]
DRIVE
6
40

OUTLET PORT
9/16-18 SAE
3.43
[87.12]
4.5
[114.3]

2.51
[63.75]

[170.18]
6.70
5.74
[145.79

[72.13]
2.84
2.96 [75.18]

INLET PORT
3/4-16 SAE
ADJ. RELIEF
VALVE

3.72
[94.48]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

1.63
[41.40]
2.25
[57.15]

3.25
[82.55]
4.50
[114.3]

3/8-16 UNC
.625 [15.87] MFD
2 MTG. HOLES

11

Motor:

12 Volt DC, 2 Terminal, Wound Field, Medium Duty, Standard 4.5 Motor,
UL Approved, 4 Terminal Start Switch with No Boots, and Horseshoe Mounting

Pump:

GC Series Pump, Single Section, Relief Valve, Check Valve, Tang Drive

NOTE: Dimensions are inches [mm].


HYDRAULIC SCHEMATIC
ROTATION
4
6
5/16-24
UNF-2A
2 TERM.

40

3.18
[80.77]

2.27
[57.65]

OUTLET PORT
3/8-18 NPT
(THIS SIDE)
INLET PORT
1/2-14 NPT
(OPP. SIDE)

CUSTOMERS
POWER
CONNECTION
(2) 5/16-18
UNF-2A

CUSTOMERS
SWITCH
CONNECTIONS
(2) #10-32 TERM.

4.43 [112.52]
PORTS

CL

ADJ. RELIEF
VALVE

.50 [12.7]

CL

DRIVE

2.50 [63.5]
CHECK
VALVE

1.50
[38.1]

10.0 [254.0]
11.25 [285.75]

3/8-16 UNC-2B
X .62 [15.74] DP.
(2) MTG. HOLES

1.625
[41.27]
2.25
[57.15]

12

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

3.00
[76.2]
3.25
[82.55]
4.50
[114.3]

Motor:

12 Volt DC, 2 Terminal, Wound Field, Medium Duty, Standard 4.5 Motor,
UL Approved, 4 Terminal Start Switch with No Boots, and Motor Foot Mounting

Pump:

GC Series Pump, Single Section, Relief Valve, Check Valve, Tang Drive

NOTE: Dimensions are inches [mm].

3.96
[100.58]

2X
5/16-24
UNF-2A

CUSTOMERS
SWITCH
CONNECTIONS
(2) #10-32 UNF-2A

HYDRAULIC SCHEMATIC

ROTATION
4

CUSTOMERS
POWER
CONNECTION
5/16-24 UNF-2A

6
40 MOTOR TERM.

12 VOLT, 2 TERM.,
DC MOTOR

7.41 [188.24]
OUTLET PORT
9/16-18 SAE
4.50 [114.3]
PORTS

INLET PORT
3/4-16 SAE

CHECK
VALVE

ADJ. RELIEF
VALVE

CL

.50 [12.7]
CL

DRIVE
3.05 [77.47]

.38
[9.65]

[76.2]
3.00
3.75 [95.25]

2.75
[69.85]

[61.97]
2.44
2.56
[65.02]

[61.97]
2.44
3.25 [82.55]

10.41
[264.41]

2.00
[50.8]

[123.69]
4.87
[165.1]
6.50
2.22
[56.38]

1.25
TYP. (4)
.375
TYP. (4)
HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

13

Motor:

24 Volt DC, 2 Terminal, Wound Field, Medium Duty, Standard 4.5 Motor,
UL Approved, 4 Terminal Start Switch with No Boots, and Horseshoe Mounting.

Pump:

GC Series Pump, Single Section, Relief Valve, Check Valve, Solenoid Valve Cavity
w/ Steel Plug, Tang Drive

NOTE: Dimensions are inches [mm].


ROTATION
HYDRAULIC SCHEMATIC
[101.6]
4.0
5/16-24
UNF-2A
2X TERM.

CUSTOMERS
POWER
CONNECTION
5/16-24 UNF-2A

35
INLET PORT
3/4-16 SAE
(OPP. SIDE)
(PLASTIC PLUG)

6.50 [165.1]

40

CUSTOMERS
OUTLET PORT SWITCH
9/16-18 SAE CONNECTION
(THIS SIDE)
#10-32 UNF-2A
(PLASTIC PLUG)

MOTOR
TERM.

VALVE
CAVITY
(STEEL
PLUG)

4.50
[114.3]

DRIVE

CHECK
VALVE

.50 [12.7]
PORTS
2.50
[63.5]

[170.18]
6.7

[10.41]
.41
10.89
[276.60]

[61.21]
2.41
3.20 [81.28]
.32
[8.12]

ADJ. RELIEF
VALVE

1.63
[41.40]
2.25
[57.15]
3.2 [81.28]

[16.76]
.66
3.25
[82.55]
4.50
[114.3]

14

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

3/8-16
UNC-2B
X .625 [15.87]
MFD (2) MTG.
HOLES

Motor:

12 Volt DC, 2 Terminal, Wound Field, Light Duty, 3 Motor, No Start Switch,
Integrated Pump Stator Mounting, UL Approved

Pump:

GC Series Pump, Single Section, Relief Valve, Direct Drive

NOTE: Dimensions are inches [mm].

HYDRAULIC SCHEMATIC

ROTATION

.88 [22.35]
ADJ. RELIEF
VALVE

.50 [12.7]
REF X 2

1.50 [38.1]

2X
.26
[6.60]
2X
4.27
[108.45]

9.49
[241.04]

2X
2.87
[72.89]
3.62
[91.94]

INLET PORT
9/16-18 SAE
(OPP. SIDE)
OUTLET PORT
9/16-18 SAE
(THIS SIDE)

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

3.00
[76.2]

1.50
[38.1]
1.75
[44.45]

2X 5/16-18 UNC-2B
x .63 [16.0] DEEP

3.50
[88.9]

15

AERIAL LIFTS
Scissor & Boom Lifts
(Primary Power)

These pump and motor units are designed for scissor and boom lift vehicles for primary power applications. These units provide hydraulic power to propel, raise and steer the vehicles. Pumping
requirement may be provided for by single or multiple sections. The pump may be supplied with a
tube inlet or other standard inlet porting. Electrical D.C. motors may be provided in 24, 36 or 48
volt combinations. The units may be equipped with pressure holding check valves, over-pressurization protecting relief valves, or even pressure unloading valves to optimize system operation.

16

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Open Drip Proof, UL Approved,
No Start Switch, Motor Foot Mounting

Pump:

GC Series Pump, Single Section, No Valves, Direct Tang


NOTE:

Slippage could occur at higher pressures. You may need to specify a PB (Pressure Balanced) pump for
improved ow at higher pressures for the larger displacement pumps (.226 in.3 and up).

NOTE: Dimensions are inches [mm].


ROTATION

8.56
[217.24]

11.75
[298.45]

HYDRAULIC
SCHEMATIC

22.5

2.44
[61.97]

7.31
[185.67]

1.50
[38.1]

22.5
1.50
[38.1]
2X
3.66
[92.96]

INLET PORT
3/4-16 SAE

6.30 [160.02]

5.62
[142.74]

.50
[12.7]

OUTLET
PORT

2.85 [72.39]

OUTLET PORT
9/16-18 SAE
.50
[12.7]

2.75
[69.85] 3.75
[96.25]

.20
[5.08]

2X
2.44 [61.97
6.38
[162.05]

1.88
[47.75]

2X
2.44 [61.97

[22.35]
.88
.44 [11.17]
.34 [8.63]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

17

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Open Drip Proof, UL Approved,
No Start Switch, Motor Foot Mounting

Pump:

GC Series Pump, Single Section, No Valves, Flex Coupling Drive for Low Noise
Operation
NOTE:

Slippage could occur at higher pressures. You may need to specify a PB (Pressure Balanced) pump for
improved ow at higher pressures for the larger displacement pumps (.226 in.3 and up).

NOTE: Dimensions are inches [mm].


ROTATION
HYDRAULIC
SCHEMATIC
22.5
2X TERMINAL
3/8-16 UNC-2A THD.

22.5

1.50
[38.1]

1.50
[38.1]
2X
3.66
[92.96]

24 VDC, 4 HP, 2 TERMINAL


SERIES WOUND MOTOR

.88 [22.35]

5.14
[130.55]

6.30 [160.02]

2X .50 [12.7] 3.29


[83.56]
1.88 [47.75]
2.85 [72.39]

2X
.56
[14.22]

2X
2X
3.45
3.00
[87.63]
[76.2]
4.13
[104.90]
2X 8.13 [206.50]
11.02 [279.90]
14.19
[360.42]

18

.20
[5.08]
2X
2.42
[61.46]

OUTLET
PORT

2X
2.44
[61.97]

2X
2.44
[61.97]
6.38
[162.05]

.44 [11.17]
.34 [8.63]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

[22.35]
.88

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Open Drip Proof, UL Approved,
No Start Switch, Motor Foot Mounting

Pump:

GC Series Pump, Two Section, No Valves, Flex Coupling Drive for Low Noise
Operation
NOTE:

Slippage could occur at higher pressures. You may need to specify a PB (Pressure Balanced) pump for
improved ow at higher pressures for the larger displacement pumps (.226 in.3 and up).

NOTE: Dimensions are inches [mm].


HYDRAULIC
SCHEMATIC

16.10 [408.94]
11.44 [290.57]
8.13
[206.5]

ROTATION

3.91
[99.31]
2.41
[61.21]
30

2X 3/8-16 UNC-2A THD.

OUTLET
PORT
9/16-18
SAE

OUTLET PORT
9/16-18 SAE

90
1.50
[38.1]
3.00
[76.2]
2.92
[74.16]

1.02 [25.9]

3.63 [92.2]
5.50
[139.7]

2.84
[72.13]

2.41
[61.21]

INLET PORT
3/4-16 SAE

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

DRIVE

PORTS
.50 [12.7]
1.88
[47.75]

3.75
[95.25]
2.50 [63.5]
5.00
[127.0]

.19 [4.82]
4X
.411/.401
[10.43] [10.18]

19

Motor:

48 Volt DC, 2 Terminal, Permanent Magnet, Extended Duty, Thermal Overload


Protection, Motor Foot Mounting

Pump:

GC Series Pump, Three Section, No Valves, Flex Coupling Drive for Low Noise
Operation

NOTE: Dimensions are inches [mm].


HYDRAULIC SCHEMATIC

[469.39]
18.48
10.22
[259.58]

ROTATION

5.69 [144.52]
4.19 [106.42]
4.06 [103.12]
2.56 [65.02]
2.44
[61.97]

[167.38]
6.59

6.80
[172.72]
.50
[12.7]
REF

.50
[1.27]

20

4.0
[101.6]

3.0
[76.2]

3.34
[84.83]

7/16-20 SAE
OUTLET PORT
7/8-14 SAE
(OPP. SIDE)
INLET PORT
(THIS SIDE)
7/8-14 SAE
PLASTIC PLUG
AUXILIARY
3/4-16 SAE
INLET PORT
OUTLET PORT
(THIS SIDE)
(OPP. SIDE)
STEEL PLUG
PLASTIC PLUG
3/4-16 SAE
OUTLET PORT
(OPP. SIDE)
PLASTIC PLUG

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

3.50 [88.9]

[61.97]
2.44
3.25
[82.55]

[61.97]
2.44
6.5
[165.1]

Motor:

24 Volt DC, 2 Terminal, Permanent Magnet, Extended Duty, Open Drip Proof,
No Start Switch, Motor Foot Mounting

Pump:

GC Series Pump, Three Section, Relief Valve, Check Valve, Unload Valve, Flex
Coupling Drive for Low Noise Operation

NOTE: Dimensions are inches [mm].

HYDRAULIC SCHEMATIC
ROTATION

13.06 [331.72]

RELIEF VALVE

21.12
[536.44]
3/4-16 SAE
OUTLET PORT
(OPP. SIDE)

11.22
[284.98]

3/4-16 SAE
OUTLET PORT
(OPP.
SIDE)

UNLOAD
VALVE

CHECK VALVE

6.89 [175.00]

4.03 [102.36]
2.41
[61.21]

??

3.50
[88.9]
4.16
[105.66]

7/8-14 SAE
INLET PORT

8.03
[203.96]

[76.2]
3.0
4.0 REF
[101.6]

2.44 [61.97]
6.5
[165.1]

3.25 [82.55]
4.88
[123.95]

3.34
[84.83]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

21

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Open Drip Proof, UL Approved,
No Start Switch, Motor Foot Mounting

Pump:

GC Series Pump, Two Section, No Valves, Flex Coupling Drive for Low Noise
Operation
NOTE:

Slippage could occur at higher pressures. You may need to specify a PB (Pressure Balanced) pump for
improved ow at higher pressures for the larger displacement pumps (.226 in.3 and up).

NOTE: Dimensions are inches [mm].


HYDRAULIC
SCHEMATIC

16.10 [408.94]
11.44 [290.57]
8.13
[206.5]

ROTATION

3.91
[99.31]
2.41
[61.21]

2X 3/8-16 UNC-2A THD.

OUTLET PORT
9/16-18 SAE

30

OUTLET
PORT
9/16-18
SAE

90
1.50
[38.1]
3.00
[76.2]
2.92
[74.16]

1.02
[25.9]

22

3.63 [92.2]
5.50
[139.7]

2.84
[72.13]

2.41
[61.21]

INLET PORT
3/4-16 SAE

DRIVE

3.75
[95.25]

PORTS
.50 [12.7]
1.88
[47.75]

2.50 [63.5]
5.00
[127.0]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

.19 [4.82]
4X
.411/.401
[10.43] [10.18]

MATERIAL HANDLING
Forklifts ( Pallet Trucks)

These pump and motor power units are designed for the Material Handling market for pallet trucks
that require separate motor, pump and reservoir packages. They are available in both 12 and 24
volt motor options that comply with the requirements of UL583. The units provide primary hydraulic
power for lifting. Power units are available with valving that incorporates pressure holding check
valves, solenoid operated directional control valves and over-pressurization protecting relief valves.

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

23

Motor:

12 Volt DC, 2 Terminal, Wound Field, Medium Duty, Standard 4.5 Motor,
UL Approved, Start Switch, and Horseshoe Mounting

Pump:

GC Series Pump, Single Section, Relief Valve, Tang Drive

NOTE: Dimensions are inches [mm].


ROTATION

HYDRAULIC SCHEMATIC
[155.70]
6.13
5/16-24
UNF-2A
2 TERM.

90

4.05
[102.87]

CUSTOMERS POWER
CONNECTION
5/16-24 UNF-2A

OUTLET PORT
9/16-18 SAE
(OPP. SIDE)

ADJ.
RELIEF
VALVE

INLET
PORT
3/4-16
SAE

CUSTOMERS SWITCH
CONNECTION
#10-32 UNF-2A

6
40

5.69 [144.52]
PORTS
.50 [12.7]
6.85 [173.99]

DRIVE

4.50
[114.3]

2.50
[63.5]

2.84
[72.13]

[180.34]
7.10
10.20
[259.08]

24

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

[16.66]
.656
[82.55]
3.250
2.219
[56.36]
4.5
[114.3]

[41.27]
1.625
2.250
[57.15]

3/8-16
UNC-2B
.62 [15.74]
MFT 2 MGT.
HOLES

Motor:

24 Volt DC, 2 Terminal, Wound Field, Medium Duty, Standard 4.5 Motor,
UL Approved, 4 Terminal Start Switch with Boots, Motor Foot Mounting with
Weld Nuts

Pump:

GC Series Pump, Single Section, Relief Valve, Check Valve, Tang Drive

NOTE: Dimensions are inches [mm].


ROTATION
[180.34]
7.10
4.05
[102.87]

6.14
[155.95]
HYDRAULIC SCHEMATIC

CUSTOMERS SWITCH
CONNECTIONS
#10-32 UNF-2A

CUSTOMERS POWER
CONNECTION
5/16-24 UNF-2A
6
40

6.63 [168.40]
OUTLET PORT
1/4-18 NPTF
(THIS SIDE)
INLET PORT
1/4-18 NPTF
(OPP. SIDE)

4.50 [114.3]

DRIVE
CL
.50 [12.7]
CL
PORTS

2.62 [66.54]
CHECK
VALVE

.56
[14.22]

3.62 [91.94
4.74 [120.39]

1.44
[36.57]

[61.97]
2.44
2.56 [65.02]

ADJ.
RELIEF
VALVE

.32 [8.12]
[52.32]
2.06
4X
1/2-13 UNC-2B

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

5.0
[127.0]

[52.32]
2.06
2.5 [63.5]

25

MATERIAL HANDLING
Forklifts
(Stackers)

These pump and motor power units are designed for the Material Handling market for high reach
stackers that require separate motor, pump and reservoir packages. They are available in 12 to
48 volt motor options which comply with the requirements of UL583. The units provide primary
hydraulic power for lifting and, under certain applications, can provide secondary power for fork
carriage extension or side-to-side shift operation. Power units are available with valving that incorporates pressure holding check valves, solenoid operated directional control valves and over-pressurization protecting relief valves.

26

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Open Drip Proof,
UL583 Approved, Heavy Duty 4 Terminal Start Switch with Boots, Motor
Foot Mounting

Pump:

GC Series Pump, Single Section, Relief Valve, Check Valve, Solenoid Lift-Hold-Lower
Valve, Tang Drive
NOTE: Slippage could occur at higher pressures. You may need to specify a PB (Pressure Balanced) pump for
improved ow at higher pressures for the larger displacement pumps (.226 in.3 and up).

NOTE: Dimensions are inches [mm].

(2) TERMINALS
3/8-16 UNC-2A THD.
W/LOCKWASHERS
7.63 [193.80]
7.51 [190.75]

HYDRAULIC
SCHEMATIC

16.6
[421.64]
10.9 [276.86]

CUSTOMERS
SWITCH
CONNECTION
.250 x .032 TABS
[6.35] [0.81]
ROTATION
CUSTOMERS
POWER
CONNECTION
M10 x 1.5
SOLENOID
RELEASE
VALVE N.C.
24 VDC

BOOT (2)
CABLE

ADJ.
RELIEF
VALVE

7.4
[187.96]

5.30
[134.62]
D MAX.

2.91 [73.91]
2.79 [70.86]
INLET PORT
3/4-16 SAE
(THIS SIDE)
1.02
[25.9]

3.63
[92.2]
5.50
[139.7]

2.25
[57.15]

2.84
[72.13]

OUTLET PORT
9/16-18 SAE
(OPPOSITE
SIDE)

CHECK
VALVE
.406 D.
[10.31]
4 MTG.
HOLES

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

1.875
[47.62]
2.50
[63.5]
2.73
[69.34]
5.9
[149.86]

3.75
[95.25]
5.00
[127.0]

27

MATERIAL HANDLING
Forklifts
(Narrow Aisle
or 3-Wheel Sit Down)

These pump and motor power units are designed for the Material Handling market for narrow aisle
or 3-wheel sit down forklifts that require separate motor, pump and reservoir packages. They are
available in 12 to 48 volt motor options which comply with the requirements of UL583. These units
provide primary hydraulic power for lifting and vehicle steering along with secondary power for fork
carriage extension or side-to-side shift operation. Power units are available with valving that incorporates pressure holding check valves and over-pressurization protecting relief valves.

28

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, 5 Motor, UL Approved,


Open Drip Proof, No Start Switch, Motor Foot Mounting

Pump:

GC Series Pump, Single Section, Tang Drive, Inlet Tube


NOTE:

Slippage could occur at higher pressures. You may need to specify a PB (Pressure Balanced) pump for
improved ow at higher pressures for the larger displacement pumps (.226 in.3 and up).

NOTE: Dimensions are inches [mm].


HYDRAULIC
SCHEMATIC
ROTATION
14.74 [374.39]
10.90 [276.86]
7.57 [192.27]
3.65 TYP. (2)
[92.71]

2X TERMINAL
3/8-16 UNC-2A THD.
90

.50 [12.7]
5.05 [128.27]
30
2.98
2.86
[75.69]
[72.64]

3/4-16 SAE
OUTLET PORT
(THIS SIDE)
?? 1 O.D. TUBE
INLET PORT
(OPP. SIDE)
??

3.09
[78.48]
.88
[22.35]

3.62 [91.94]
5.38 [136.65]

2.25
[57.15]
2.41
[61.21]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

1.885 [47.87]
1.865 [47.37]
3.75
[95.25]
5.0
[127.0]

2.5 [63.5]
3.0
[76.2]

.187 [4.74]
4X
.411/
.401
[10.43]
[10.18]
MTG.
HOLES

29

Motor:

12 Volt DC, 2 Terminal, Wound Field, Extended Duty, 5 Motor, UL Approved,


Open Drip Proof, No Start Switch, Motor Foot Mounting

Pump:

GC Series Pump, Single Section, Relief Valve, Check Valve, Tang Drive
NOTE:

Slippage could occur at higher pressures. You may need to specify a PB (Pressure Balanced) pump for
improved ow at higher pressures for the larger displacement pumps (.226 in.3 and up).

NOTE: Dimensions are inches [mm].


HYDRAULIC
SCHEMATIC
12.81
[325.37]
ROTATION
2.44
[61.97]

8.63
[219.20]

.32
[8.12]
45

45

2.73
[69.34]

[16.76]
.66
3/8-16 UNC-2A
2 TERMS.

ADJ. RELIEF
VALVE
2.63
5.06 [66.80]
[127.0]

C
L

.50 [12.7]
C
L
PORTS
2.88
[73.15]

OUTLET PORT
3/4-16 SAE
(THIS SIDE)
3.62
[91.94]
5.75
[146.05]

30

CHECK
VALVE

DRIVE

3.59 [91.18]
TYP.

.13 [3.3]
INLET PORT
9/16-18 SAE
(OPP. SIDE)
[52.32]
2.06

1.44
[36.57]
2.63
[66.80]

3.23
[82.04]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

4.12
[104.64]
5.0
[127]

[63.5]
2.5

.437 [11.09]
DIA. 4 HOLES

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Open Drip Proof, UL Approved,
No Start Switch, Motor Foot Mounting

Pump:

PB Series Pump, Single Section, Check Valve, Relief Valve, Solenoid Release Valve
with Manual Override (L-H-L), Tang Drive

NOTE: Dimensions are inches [mm].


HYDRAULIC
SCHEMATIC
10.90
[276.86]

ROTATION

.31 [7.87]

15.08
[383.03]

24 VDC SOLENOID
RELEASE VALVE W/
MANUAL OVERRIDE

3.72
[94.48]
3.65 [92.71]
2.71
[68.83]
2.18
[55.37]

7.56 [192.02]
3/8-16 UNC-2A THD.
2 TERM.

5.12 [130.04]

30
3/4 O.D.
TUBE
(SOLENOID
RETURN TO
TANK)

3.65 [92.71]

90

3.01 [76.45]

ADJ.
RELIEF
VALVE

PORTS
CL
.50 [12.7]
CL

CHECK
VALVE
OUTLET PORT
3/4-16 SAE
(THIS SIDE)
[25.9]
1.02

[92.2]
3.63

5.50
[139.7]

2.25
[57.15]

DRIVE

.187
[4.74]

INLET PORT
7/8-14 SAE
(OPP. SIDE)
.411/.401
[10.43]/
[10.18]
DIA.
(4) MTG.
HOLES

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

3.75
[95.25]
5.00
[127]

2.98 [75.69]
2.86 [72.64]

1.88
[47.75]
2.50
[63.5]

4.37
[110.99]

31

Motor:

36/48 Volt DC, 2 Terminal, Externally Vented, Permanent Magnet Motor,


Continuous Duty, Open Drip Proof, Motor Foot Mounting

Pump:

Single Section Split Gear Pump, Relief Valve, Check Valve, Flex Coupling
Drive for Low Noise Operation

HYDRAULIC
SCHEMATIC

NOTE: Dimensions are inches [mm].

ROTATION
13.50
[342.9]

2.44
[61.97]
TYP.
AUX. PRESSURE
PORT 7/16-20
(STEEL PLUG)
1.28
[32.51]

9.80 [248.92]
8.66
[219.96]

15

15

2X 5/16-18 UNC-2A

OUTLET PORT
9/16-18 SAE
(PLASTIC PLUG)

7.32 [185.92]
[62.23]
2.45
3.50 [88.9]

.50
[12.7]

3.00
[76.2]
4.00
[101.6]

3.50
[88.9]

EXTERNALLY VENTED
RELIEF

.12
[3.04]
.62 [15.74]
O.D. TUBE

PORT
[61.97]
2.44
3.31
[84.07]

DRIVE
.50 [12.7] (REF)
[123.95]
4.88
6.62
[168.14]
.34 [8.63]

.44 [11.17]
.88
DETAIL OF MOUNTING SLOT
[22.35] TYP. 4

32

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

CONSTRUCTION
Supplemental Steering

These pump and motor power units are designed for applications requiring a secondary source for
supplying steering when the primary source becomes nonfunctional.
The pumps are available in single or multiple section, designed with optional priority load sense in
the rear valve cover. Motor construction is suited for applications in off-highway equipment where
the conditions are harsh, and rugged performance is required. Power units can be constructed with
heavy duty start switches and insulated wiring boots.

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

33

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Sealed Motor, Motor
Foot Mounting

Pump:

W600 Series Pump, Single Section, 9 Tooth Spline, Adjustable Relief Valve,
Side Inlet/Outlet Porting

CUSTOMERS POWER
CONNECTION
CUSTOMERS SWITCH
CONNECTION

CUSTOMERS GROUND
CONNECTION
ROTATION

NOTE: Dimensions are inches [mm].

ELECTRIC / HYDRAULIC SCHEMATIC

14.18
[360.17]
10.31 [261.87]
3.44
[87.37]

7.60
[193.04]

CUSTOMERS
SWITCH CONNECTION
2X #10-32 UNF-2A

1.92
[48.76]

ADJ. RELIEF VALVE

60

5.0
[127.0]

CUSTOMERS
POWER
PORTS CONNECTION
2X 5/16-24
UNF-2A
.50 [12.7]

7.36
[186.94]

DRIVE
30
OUTLET PORT
3/4-16 SAE
(THIS SIDE)

2.92
[74.16]

INLET PORT
7/8-14 SAE
(OPP. SIDE)
.88
[22.35]

34

3.62
[91.94]

5.38
[136.65]

2.39
[60.7]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

[95.25]
3.75
4X
.438/.500 [11.12]/[12.7]
MTG. HOLES 5.88
[149.35]
2X M10
TERM.

1.88
[47.75]
2.50
[63.5]
TYP.

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Sealed Motor, No Start
Switch, Motor Foot Mounting

Pump:

W900 Series Pump, Single Section, 9 Tooth Spline, No Valves, Rear Inlet/Outlet

NOTE: Dimensions are inches [mm].

HYDRAULIC SCHEMATIC
ROTATION
[261.87]
10.31

2X M10 TERM.
7.60
[193.04]

.94
.94
[23.87] [23.87]
6.30 [160.02]
60

5.0 [127.0]

INLET PORT
3/4-16 SAE
(PLASTIC PLUG)

PORTS
.63 [16]REF
DRIVE

3.55 [90.17]
OUTLET
PORT
9/16-18 SAE
(PLASTIC
PLUG)

30

[22.35]
.88

[91.48]
3.62
5.38
[136.65]

2.39
[60.70]

.062
[1.57]

4.28
[108.71]

4X .411/.401
[10.43/10.18]
MTG. HOLES

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

3.75
[92.25]
5.88

[47.75]
1.88
2.50 [63.5]
TYP.

35

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Sealed Motor, Heavy Duty
4 Terminal Start Switch Without Boots, Motor Foot Mounting

Pump:

W900 Series Pump, Single Section, 9 Tooth Spline, No Valves, Side Inlet/Outlet

CUSTOMERS POWER
CONNECTION
CUSTOMERS SWITCH
CONNECTION

CUSTOMERS GROUND
CONNECTION
ELECTRIC / HYDRAULIC
SCHEMATIC

ROTATION

NOTE: Dimensions are inches [mm].


7.60
[193.04]

CUSTOMERS
SWITCH
CONNECTIONS

[118.61]
4.67

[261.87]
10.31
2.29
[58.16]

CUSTOMERS
POWER
CONNECTION
M10 x 1.5

30

60

5.0 [127.0]
PORTS

7.57 [192.27]

.63 [16] REF


DRIVE
2.92
[74.16]

30
OUTLET PORT
7/8-14 SAE
(THIS SIDE)
[22.35]
.88

[60.70]
2.39

[91.94]
3.62
5.38
[136.65]

36

INLET PORT
1 1/16-12 SAE
(OPP. SIDE)

.062
[1.57]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

2X M10
TERM.

[95.25]
3.75
4X
.411/.401 [10.43/
10.18] MTG. HOLES
5.88
[149.35]

[47.75]
1.88
2.50 [63.5]
TYP.

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Sealed Motor, Heavy Duty
4 Terminal Start Switch with Boots, Motor Foot Mounting

Pump:

W900 Series Pump, Single Section, 9 Tooth Spline, Adjustable Relief Valve,
Rear Inlet/Outlet

CUSTOMERS POWER
CONNECTION
CUSTOMERS SWITCH
CONNECTIONS

NOTE: Dimensions are inches [mm].


CUSTOMERS GROUND
CONNECTION

2X M10 TERM.

ELECTRIC / HYDRAULIC SCHEMATIC


[261.87]
10.31
7.60
[193.04]

15.88 MAX.
[403.35]

ROTATION

CUSTOMERS
SWITCH
CONNECTIONS
.250 x .032 TABS
[635] [.81]
CUSTOMERS
POWER
CONNECTION
M10 x 1.5 [38.1]

RELIEF VALVE

5.0
[127.0]

2.34 [59.43]

BOOT (2)

60
7.57 [192.27]

PORTS
.63 [16] REF
DRIVE
30

2.92
[74.16]

.88
[22.35]

3.62
[91.94]

2.39
[60.70]
4.48
[113.79]

5.38
[136.65]

.062
[1.57]
2.03
[51.56]

INLET PORT
3/4-16 SAE
(THIS SIDE)

4X M10 x 1.5
[38.1] WELDED NUTS

OUTLET PORT
3/4-16 SAE
(OPP. SIDE)
HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

[87.37]
3.44
1.88 [47.75]
3.75
[92.25]
2.50 [63.5]
TYP.
5.88
[149.35]

37

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Sealed Motor,


No Start Switch, Motor Foot Mounting

Pump:

W900 Series Pump, Single Section, 9 Tooth Spline, Side Inlet/Outlet,


Priority Load Sense in Rear Valve Cover

LS

PRI

NOTE: Dimensions are inches [mm].

EX

HYDRAULIC
SCHEMATIC
(16.65)
[(422.91)]

ROTATION
2X M10 TERM.

9/16-18 SAE
DYNAMIC LOAD
SENSE PORT

1 1/16-12 SAE
INLET PORT
(OPP. SIDE)

6.26
[159]

10.31
[261.87]
7.60
[193.04]

.062
[1.57]

60
.54
[13.71]
6.30 [160.02]

5.0 [127.0]
30

3/4-16 SAE
PRIMARY OUTLET
(OPP. SIDE)
4X
.411/.401
[10.43/10.18]
MTG. HOLES

38

3.75
[95.25]
5.88
[149.35]

1.88
[47.75]
2.50
[63.5]
TYP.

[50.03]
1.97
5.31
[134.87]

2.39
[60.70]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

[91.94]
3.62
5.38
[136.65]

[22.35]
.88

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Sealed Motor, No Start
Switch, Motor Foot Mounting

Pump:

W900 Series Pump, Two Section (Sealed Between Sections), 9 Tooth Spline,
Side Inlet/Outlet, Priority Load Sense in Rear Valve Cover

PRI

LS

NOTE: Dimensions are inches [mm].


EX

HYDRAULIC SCHEMATIC

ROTATION
2X M10 TERM.
3/4-16 SAE
PRIMARY OUTLET

19.63
[498.60]

9.26
[235.20]
8.31
[211.07]

7.60
[193.04]

1.73
[181.10]

6.30 [160.02]
60

10.31
[261.87]

2.84 [72.13]
5.0
[127.0]
.54 [13.71]
30

[92.25]
3.75
4X .411/.401[10.43/
10.18] MTG. HOLES
5.88
149.35]
9/16-18 SAE
DYNAMIC LOAD
SENSE PORT

[47.75]
1.88
2.50
[63.5]
TYP.

INLET
PORT
1-1/16-12
SAE

OUTLET PORT
3/4-16 SAE
(OPP. SIDE)
INLET PORT
7/8-14 SAE
(THIS SIDE)

[60.70]
2.39
.062
[1.57]

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

5.38
[136.65]

3.62 [91.94]

[22.35]
.88

39

Motor:

24 Volt DC, 2 Terminal, Wound Field, Extended Duty, Sealed Motor, Heavy Duty
4 Terminal Start Switch with Boots, Motor Foot Mounting

Pump:

W900 Series Pump, Single Section, 9 Tooth Spline, Side Inlet/Outlet,


Priority Load Sense in Rear Valve Cover

PRI

NOTE: Dimensions are inches [mm].

LS

CUSTOMERS POWER
CONNECTION
CUSTOMERS SWITCH
CONNECTIONS
EX
CUSTOMERS GROUND
CONNECTION

HYDRAULIC SCHEMATIC

(16.65)
[(422.91)]

ROTATION
CUSTOMERS
CUSTOMERS
SWITCH
POWER
CONNECTIONS
CONNECTION .250 [6.35] x .032 [.81] TABS
M10 x 1.5 [38.1]

6.28
[159.51]
.062
[1.57]

1-1/16-12 SAE
INLET PORT
(OPP. SIDE)

BOOT (2)

10.31
[261.87]
7.60
[193.04]

9/16-18 SAE
DYNAMIC LOAD
SENSE PORT
60
.54 [13.71]
7.57 [192.27]

5.0[127.0]

30
3/4-16 SAE
PRIMARY OUTLET
(OPP. SIDE)

2X
M10
TERM.
4X
.411/.401
[10.43/10.18]
MTG. HOLES

40

[47.75]
1.88
3.75
[95.25]
5.88
[149.35]

[50.03]
1.97
5.31
[134.87]

2.39
[60.70]

2.50
[63.5]
TYP.

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

[91.94]
3.62
5.38
[136.65]

[22.35]
.88

PUMPS & MOTORS


Cast Iron Pumps

Heavy Duty

Aluminum Pumps

Medium/Light Duty

GC Series Pumps

W-Series Pumps

Displacements

W100 Displacements

0.065 to 0.711 cu. In. (1.06 to 11.65 cc)

0.031 to 0.122 cu. In. (0.50 to 2.00 cc)


W300 Displacements

GC Series High/Low Pumps

0.049 to 0.347 cu. In. (0.80 to 5.70 cc)

High Pressure Displacements

W600 Displacements

0.065 to 0.258 cu. In. (1.06 to 4.22 cc)

0.244 to 0.732 cu. In. (4 to 12 cc)

Low Pressure Displacements

W900 Displacements

0.258 to 0.776 cu. In. (4.22 to 12.71 cc)

0.305 to 1.891 cu. In. (5 to 31 cc)

Maximum Pressure

W1200 Displacements

4,000 psi (276 bar)

1.526 to 2.014 cu. In. (25 to 33 cc)

Maximum Speed

W1500 Displacements

1.159 to 3.051 cu. In. (19 to 50 cc)

4,000 rpm

Maximum Pressure

4,000 psi (276 bar)

F12 & F15 Ferra Series Pumps

Maximum Speed

F12 Displacements

500 to 4,000 rpm

0.976 to 2.502 cu. In. (16 41 cc)


F15 Displacements

1.159 to 3.051 cu. In. (19 to 50 cc)

WQ900 Pumps

Maximum Pressure

Displacements

4,000 psi (276 bar)

0.305 to 1.648 cu. In. (5 to 27 cc)

Maximum Speed

Maximum Pressure

3,600 rpm

3,336 psi (230 bar)


Maximum Speed

4,000 rpm

F20/F30 Pumps & F20-LS/F30-LS


Load Sense Ferra Series Pumps
Displacements

1.41 to 9.82 cu. In. (23 to 161 cc)

Fluid Motors

Maximum Pressure

4,000 psi (276 bar)

Cast Iron

Maximum Speed

Displacements

3,600 rpm

0.065 to 9.82 cu. In. (1.06 to 161 cc)


Speed

Up to 10,000 rpm

D Series Pumps
Displacements

Aluminum

0.232 to 1.395 cu. In. (3.80 to 22.85 cc)

Displacements

D Series High/Low Pumps

0.244 to 3.050 cu. In. (4 to 50 cc)

High Pressure Displacements

Speed

0.465 cu. In. (7.62 cc)

Up to 4,000 rpm

Low Pressure Displacements

0.930 to 1.395 cu. In. (15.24 to 22.86 cc)


Maximum Pressure

3,000 4,000 psi (207 276 bar)

Flow Dividers

Maximum Speed

GC & D Series

3,6004,000 rpm

GC Displacements

0.097 to 0.517 cu. In. (1.58 to 8.47 cc)


D Displacements

0.232 to 0.813 cu. in. (3.8 to 13.32 cc)


Call us for more information
For application assistance or detailed literature on any
Haldex product line, call us toll-free: 1-800-572-7867.
Visit our web site: http://www.haldex.com/hbus
E-mail us: info.hydraulics.us@haldex.com
HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

Maximum Pressure

4,500 psi (310 bar)


Maximum Input Flow Per Section

14 gpm (53 lpm)

41

Only Haldex offers this extensive range of products worldwide.

POWER PACKS

PUMP/MOTORS (DC/AC)

HE BOX POWER PACKS

DC Voltage Range

Voltage Range

12 to 72 VDC

12 to 24 VDC

AC Horsepower Range

Pump Displacements

1/2 to 3 HP

0.049 to 0.388 cu. In. (0.80 to 6.36 cc)

Pump Displacements

Maximum Pressure

0.04 1.71 cu. In. (0.65 to 28 cc)

3,336 psi (230 bar)

Maximum Pressure

Reservoirs

4,000 psi (276 bar)

3 qt. to 5.0 gal. (2.84 to 19 ltr.) steel

HB800 POWER PACKS


Voltage Range

HE-Q (QUIET) POWER PACKS


Voltage Range

24 VDC

12 to 24 VDC

WQ300 Pump Displacements

Pump Displacements

0.037 to 0.092 cu. In. (0.60 to 1.5 cc)


Reservoirs

0.13 to 1 gal. (.5 to 3.8 ltr.) plastic

0.073 to 0.347 cu. In. (1.2 to 5.7 cc)


Noise

42dB(A)

Maximum Pressure

2,610 psi (180 bar)

HE1000 SERIES POWER PACKS

BIROTATIONAL POWER PACKS

Voltage Range

Voltage Range

12 to 24 VDC

12 to 24 VDC, 115 to 230 VAC

Pump Displacements

Pump Displacements

0.015 to 0.122 cu. In. (0.24 to 2 cc)

0.049 to 0.129 cu. In. (0.80 to 2.11 cc)

Maximum Pressure

Reservoirs

3,336 psi (230 bar)

2 to 2.96 qt. (1.9 to 2.8 ltr.) plastic,


1 to 2 gal. (3.8 to 7.6 ltr.) steel

Reservoirs

0.13 to 1.0 gal. (0.5 to 3.8 ltr.) plastic

HE2000 SERIES POWER PACKS


Voltage Range

AC POWER PACKS
GC-9500 SERIES

12 to 24 VDC, 115 to 230 VAC

Displacements

Pump Displacements

0.065 to 1.394 cu. In. (1.06 to 22.85 cc)

0.049 to 0.388 cu. In. (0.80 to 6.36 cc)

Maximum Pressure

Maximum Pressure

3,000 psi (207 bar)

3,336 psi (230 bar)

Maximum Speed

Reservoirs

3,600 rpm

0.95 qt. to 3.96 gal. (0.9 to 15 ltr.) steel,


0.8 to 1.7 qt. (0.76 to 1.6 ltr.) plastic

Reservoirs

Call us for more information


For application assistance or detailed literature on any
Haldex product line, call us toll-free: 1-800-572-7867.
Visit our web site: http://www.haldex.com/hbus
E-mail us: info.hydraulics.us@haldex.com

42

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

5 to 20 gal. (19 to 76 ltr.) steel

SPECIAL PRODUCTS
HYDRAULICS

Haldex provides innovative custom


solutions to the vehicle industry on
a global basis
We focus on the areas where we can create customer value.
Our applications expertise enables us to take on customers
most unique application challenges. The foundation for this
expertise is an expert knowledge of hydraulic systems. The
value we bring to our customers is our unique capability to
integrate a variety of system components and controls, to
provide multiple functions in one custom package.
Our applications specialists seek to understand the overall goals
for the vehicle, the vehicle subsystems and then the hydraulics
system. This understanding enables them to respond with
customized value engineered solutions. Haldex Hydraulics
was the first to offer many of the solutions shown here.

High-Speed Rotary
Drive Systems

Powershift Transmission
Lube and Charge

Electrohydraulic
Lifting Systems

Auxiliary
Hydraulic Power

Supplimental Power
Steering Systems

Axle Cooling and Lube


Systems

Fan Drive With Integrated


Brake Charge Function
HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

43

PRODUCT RANGE
HE Powerpacks
12/24/48 VDC 0.3 4.5 kW and
0.75 3 kW AC modular power packs
HE Box Powerpacks
12/24/48 VDC modular powerpacks
in weatherproof boxes

www.haldex.com/hbus

Pressure Switches
5 - 350 bar, connecting/disconnecting
W100 Hydraulic pumps
0.5 - 2.0 cc 227 bar
W300 Hydraulic pumps
0.8 5.7 cc 230 bar
W600 Hydraulic pumps / motors
3 12 cc 276 bar
W900 Hydraulic pumps / motors
5 31 cc/section 276 bar
Calma The new quiet pumps
6.2 - 23.7 cc/section 250 bar
WQ900 The quiet pumps
5 - 23 cc/section 230 bar
Haldex Hydraulics GmbH
Seligenweg 12, Postfach 15 07
DE-95014 HOF
Germany
Tel:
+49-9281 895-0
Fax:
+49-9281 87133
E-mail: info.hydraulics.eu@haldex.com

Haldex Hydraulics AB
Ringvgen 3, Box 95
SE-280 40 SKNES FAGERHULT
Sweden
Tel:
+46-433 32400
Fax:
+46-433 30546
E-mail: info.hydraulics.eu@haldex.com

Haldex International Trading


(Shanghai) Co. Ltd.
16 A, Zhao Feng World Trade Building
No. 369 Jiang Su Road
CN-200050 SHANGHAI
China
Tel:
+86 21 5240 0338
Fax:
+86 21 5240 0177
E-mail: info.cn@haldex.com

WP900X Hydraulic pumps


16 - 31 cc/section 276 bar
W1500 Hydraulic pumps / motors
19 - 50 cc/section 276 bar
F12 FERRA Heavy duty pumps
16 - 41 cc/section 276 bar
F15 FERRA Heavy duty pumps
19 - 50 cc/section 276 bar
F20/F30 (LS) Hydraulic pumps / motors
23 161 cc/section 276 bar
GPA Internal Gear pumps
1.7 63 cc/section 100 bar
GC Hydraulic pumps / motors
1.06 11.65 cc/section 276 bar
D Hydraulic pumps
3.8 22.9 cc/section 207 bar
II-Stage Hydraulic pumps
4.2 22.8 cc/section 276 bar
Rotary Flow Dividers
3.8 13.3 cc/section 300 bar
Transmission pumps

H a l d e x ( w w w. h a l d e x . c o m ) ,
headquartered in Stockholm,
Sweden, is a provider of proprietary
and innovative solutions to the global
vehicle industry, with focus on products in
vehicles that enhance safety, environment
and vehicle dynamics. Haldex is listed on the
Nasdaq OMX Stockholm Stock Exchange.

HALDEX-DC PUMP/MOTOR CAPABILITIES GUIDE-US-2008-12

Haldex Hydraulics Corp.


2222 15th Street
ROCKFORD, IL 61104
USA
Tel:
+1-815 398 4400
Fax:
+1-815 398 5977
E-mail: info.hydraulics.us@haldex.com

This catalog is intended for general reference


only. Haldex will not accept responsibility for any
Haldexerrors
will not and
acceptreserves
responsibility
any catalog
catalog
theforright
to modify its
errors and
reserves the
rightnotice.
to modify
its products
products
without
prior
Consult
factory
notice. This also
applies to products
forwithout
specifiprior
c application
information.
The right
already ordered,
that such improvements
modications can is
to modifi
cationprovided
for technical
be made All
without
affecting technical
cations.are
All
reserved.
trademarks
in thisspeci
material
trademarksof
in their
this material
are properties
of their
properties
respective
owners.
Printed in
respective
owners.
USA
2010.

You might also like