CALCULATION OF TOTAL CIRCUIT RESISTANCE/ total specs

1- anode to backfill resistance


Ra/b /Ohm

0.287554676035

2- Iterference factor between anodes


F

1.379369829457

3- Equivalent anode resistance


Ra
0.066107374074

4- Ground bed resistance i.e backfill versus soil, which is form normally 85%.

Rb

0.762279244799

5- Equvelent anode ground bed resistance

Rab
0.828386618873

6- CP Cables resistance

Rca
0

7- Total circuit resistance


R total/Ohm
0.828386618873
E/ total specs

backfill resistivity/Ohm.m anode length/M

r L
0.5 1.52

backfill resistivity/Ohm.m N/anode number

0.5 6

form normally 85%.


Soil resistavity active length of
backfill

r-ohm.m L-m

15 20
Anode diameter/M

D
0.05

e/ avarage distance between two anode/m Ra/b

2 0.287554676

external diameter of casing/.backfill/

D-m

0.27
Current requirments

1- surface to be protected

S-Sqm
13816

2- Current Requirment/ coated staff

I-Amper

1.379873
2.0698095 safty margine 1.5

Optrion 1
2.A- Current Requirment/ bare staff

I(Amper) area(m2) Current density(ma/m2)


7.65 255 30

11.475 SAFTY MARGINE 1.5


External
Diameter of
pipe line Pipe line length
D-m L-m
0.2 22000

Coating Current density Current area to be


damage factor to be applied on density to be protected coating coating
bare metallic applied on breakdown breakdown
surface coated factor factor
metallic
surface
X Jb-ma/m2 Jpr-ma/m2 S-Sqm b1-PE-PP b2-FBE

0.0025 20 0.05 13816 0.0025 0.005

Current density to be applied on bare metallic


sirface ma/m2 TOTAL SPECS

piping steel/aerated soil 20

tank bottom steel/salty soil 30


copper aerated soil 80
steel/concrete 10
coating
breakdown factor
b3-Epoxy coal tar
or liquid cold
applied

0.01
Determine masss consumption on service life
current design service
M-Kg demand life

Icd(A) t(year)
56.25
5 20
anode consumption anode utilization
rate factor

φ(kg/amp.year) µ
0.45 0.8