Professional Documents
Culture Documents
Doha ExpresswayPackage 6
East Industrial Road Interchanges at Intersection with Street 10 and Street 23
Contact No. C2011/085
Submittal Information
1. Document Number
EXW-P006-0000-MQ-SHC-MS-00010
2. Description
Vendor and Material Submittal for Ready Mix Concrete
3. Pages
155
4. Revision
Rev.1
5. Reference Number
EXW-P006-0000-MQ-KBR-CR-00383
6. Material Type
Ready Mix Design SRC20 & SRC 25 & SRC 30 & OPC 20 & OPC 25 &
OPC 30 & OPC 40 & OPC 50
7. Country of Origin
Qatar
8. Manufacturer
Hamad Bin Khalid Ready-Mix Co. W.L.L.
Add: P.O.Box 1362, Street 47, Industrial Area, Doha, Qatar / Tel: +974
44433644 / Fax: +974 44438729
9. Local Agent
Hamad Bin Khalid Ready-Mix Co. W.L.L.
Add: P.O.Box 1362, Street 47, Industrial Area, Doha, Qatar / Tel: +974
44433644 / Fax: +974 44438729
10. BOQ Ref.
Bill No.05/29A/35A/35B etc.
11. Specification Ref.
QCS 2007 Edition 3rd, Section 5 & Project Specification Section 5 &
Section 32
12. Drawing Ref.
SG-01-07 etc.
Doha Qatar Mob: +974 33832587 Tel: +974-44126471 Fax: +974-44126471 E-mail: dohap6@126.com www.sinohydro.com
SINOHYDRO GROUP LIMITED
Doha ExpresswayPackage 6
East Industrial Road Interchanges at Intersection with Street 10 and Street 23
Contact No. C2011/085
Index
1. Relevant Comments
2. Relevant BOQ
3. Relevant Specification
4. Company Profile
5. Specification Comparison Table
6. Manufacturers Data Sheet
7. Test Report
8. Previous Approval
Doha Qatar Mob: +974 33832587 Tel: +974-44126471 Fax: +974-44126471 E-mail: dohap6@126.com www.sinohydro.com
SECTION 1
RELEVANT COMMENTS
01 Dfg
/
ASHGHAL , 2nd floor , AJ Fabal Towor 2 , Wcst 8 :1 V,
PO Box 26666 , Doh" , Q"t"r.
Tel: + 974 4495 00'J8
KB
Ftl)(: + 97-1
C"n n h'.rd~"
.'", 034791
To:
(
Attn:
Transmittal # :
Expressway
Issue Date :
Reason for
Issue:
Format:
EXW-P006-0000-PM-KBR-TN-O 1736
18 January 2012
Issued for Action
Paper Original
Sun Jinhui
project Manager.
Document N
Rev
Status
EXW-P006-0000-PM-KBRCR-00383
RO
EXW-P006-0000-MQ-SHCMS- 00008
001 ,-002 &003
Robert Poulos
By hand
Document Title
Qty
Original
RO
4
Original
EXW-P006-0000-MQ-SHCMS-00010
RO
4
Original
EXW-P006-0000-MQ-SHCMS-00011
RO
4
Original
EXW-P006-0000-MQ-SHCMS-00016
RO
4
Original
EXW-P006-0000-MQ-SHCMS-00019
RO
4
Original
EXW-P006-0000-MQ-SHCMS-00020
RO
4
Original
Item
Comments
Mike Doran - KBR (Transmittal Only)
cc:
RECEIVED BY:
NAME
SIGNATURE
Page 1 of 1
DATE
EXPRESSWAY PROGRAMME
Operations - Review Comments Sheet
Project No:
P006
Document:
Project:
Project Code:
Date:
Document Number:
Document No.: EXW-P006-0000-PM-KBR-CR-00383
Document Name
Item
Review Comment
Date
Status
15/01/2012
Approved with
Comment
EXW-P006-0000MQ-SHC-MS-00010
EXW-P006-0000MQ-SHC-MS-00011
N/A
15/01/2012
Approved
EXW-P006-0000MQ-SHC-MS-00019
15/01/2012
Approved
EXW-P006-0000MQ-SHC-MS-00020
N/A
15/01/2012
Approved
EXW-P006-0000MQ-SHC-MS- 00008
001,-002 & 003
N/A
15/01/2012
Approved
EXW-P006-0000MQ-SHC-MS-00016
15/01/2012
Rejected
The Engineers comments are given to ensure the reviewed submission conforms to the Contract provisions and shall not be construed as limiting or relieving the Contractors liability in any way
or constituting an instruction, direction or notice to change or vary the Works.
Legends- Approved=A, Approved as noted=AAN, Revise and Re-submit=RAR, Rejected=REJ, Noted=N
Page 1 of 1
SECTION 2
RELEVANT BOQ
FINANCIAL SUBMISSION
SECTION G
BILL OF QUANTITIES
Item
BILL NO. 5
DRAINAGE AND
SERVICE DUCTS
Description
Unit Qty
Rate
Amount (Q.R.)
6,550
1,871
1,128
258
605
532
48
52
151
415
145
64
126
105
140
QR
G5 /1
January 2011
FINANCIAL SUBMISSION
SECTION G
BILL OF QUANTITIES
Item
BILL NO. 5
DRAINAGE AND
SERVICE DUCTS
Description
Unit Qty
Rate
Amount (Q.R.)
nr
34
nr
14
nr
nr
14
nr
31
nr
nr
nr
28
nr
nr
nr
11
nr
nr
nr
nr
401
Rate Only
Gullies
5.40 Polypropylene concrete surround gullies including removable
basket, concrete surrounds, gully frame and cover, pipe
fittings, excavation in any materials and backfilling,
compaction, complete as detailed on drawings and
specifications.
QR
G5 /3
January 2011
FINANCIAL SUBMISSION
SECTION G
BILL OF QUANTITIES
Item
BILL NO. 5
DRAINAGE AND
SERVICE DUCTS
Description
Unit Qty
Rate
Amount (Q.R.)
nr
nr
nr
5.56 Internal dia. 1500mm, depth to invert 5.0 - 6.0m with ramp
backdrop.
nr
nr
11
415
135
nr
Deep Manhole
QR
G5 /6
January 2011
FINANCIAL SUBMISSION
SECTION G
BILL OF QUANTITIES
Item
Unit
Qty
nr
15
nr
nr
10
nr
22
nr
nr
nr
nr
nr
13
nr
nr
nr
nr
29A.38 Extra over item 29A.21 for 200mm double flanged pipe
4000mm with integral puddle flange
nr
12
29A.39 Extra over item 29A.22 for 300mm double flanged pipe
4000mm with integral puddle flange
nr
18
nr
nr
Rate
Amount (Q.R.)
Fittings
Supply and install DI fittings as detailed on drawings and
specifications
QR
G29A/3
January 2011
FINANCIAL SUBMISSION
SECTION G
BILL OF QUANTITIES
Item
BILL NO. 35
STRUCTURES
35A- STREET 10 INTERCHANGE 33
Description
Unit
Qty
Rate
Amount (Q.R.)
75
m3
1,553
m3
280
m3
3,492
QR
G35A/6
January 2011
FINANCIAL SUBMISSION
SECTION G
BILL OF QUANTITIES
Item
BILL NO. 35
STRUCTURES
35B - STREET 23 INTERCHANGE 24
Description
Unit
Qty
Rate
Amount (Q.R.)
75
m3
1,553
m3
285
m3
3,492
QR
G35B/6
January 2011
SECTION 3
RELEVANT
SPECIFICATION
QCS 2007
Section 5
Part 6
Property Requirements
Page 3
6.2
GRADES OF CONCRETE
6.2.1
General
Grades of concrete to be used in the Works shall in general be as shown in Table 6.1.
Where different grades of concrete are required the design of the mix shall follow the
requirements of this specification.
Where adequate workability is difficult to obtain at the maximum water:cement ratio allowed,
the use of plasticisers or water reducing admixtures may be considered. Alternatively an
increase in cement content may be considered at the discretion of the Engineer where this
will not adversely affect the durability of the concrete.
Cement contents in excess of 400 kg/m shall not be used unless special consideration has
been given to reduce thermal stress in the concrete, and approval has been obtained from
the Engineer.
6.2.2
At the start of the construction period, the Contractor shall design a mix for each grade of
concrete listed in Table 6.1 that is required to be built into the Works.
(a)
(b)
(c)
(d)
3
the aggregate shall comprise fine aggregate and coarse aggregate no greater than the
maximum size specified in Table 6.1
the combined aggregate grading shall be continuous
the aggregate quantity shall be calculated by weight
the mixes shall be designed to produce a concrete cube strength at twenty-eight days
after manufacture of not less than the cube strength specified in Table 6.1.
For concrete using other than moderately sulphate resisting Portland cement (ASTM Type II)
or incorporating admixtures, the strengths shall not be less than those specified in Table 6.1,
but the mix designs shall be revised and agreed with the Engineer.
Table 6.1
Grades of Concrete
Concrete
Grade
Max. Size
Aggregate
mm
Min. Cement
3
Content kg/m
Type of
Cement
40
35
30
25
20
15
20
20
20
20
20
20
370/MSRPC
350/MSRPC
330/MSRPC
320/MSRPC
310/MSRPC
280/MSRPC
0.4-0.45
0.4-0.45
0.4-0.45
0.45-0.50
0.55
0.55
40
35
30
25
20
15
20
20
20
20
20
20
370/PC
340/PC
300/PC
0.45
0.5
0.6
Max. Free
Water:Cement
Ratio
Cube Crushing at 28 d
Trial Mix
Works
Test
Test
MPa
MPa
50
45
40
35
30
25
40
35
30
25
20
15
SECTION 4
COMPANY PROFILE
SECTION 5
SPECIFICATION
COMPARISON TABLE
SECTION 6
MANUFACTURERS
DATA SHEET
SECTION 7
TEST REPORT
SECTION 8
PREVIOUS APPROVAL