You are on page 1of 6

ISOLATED FOOTING DESIGN

FORCES DETAILS :

Axial Load = P1 =
Moment along Major axis = Mx =
Moment along Minor axis = Mz =

25 T
5.00 T-m
5 T-m
G.L

COLUMN DETAILS :

Length = ( Larger Dimension of Column )


Width = ( Smaller Dimension of Column )

0.47 m
0.47 m

FOOTING DETAILS :

Length = L =
Width = B =
Depth = D =

2 m
2 m
0.5 m

Cover to Main R/f =


Diameter of R/f in Footing =

1.5

0.05 m
12 mm
0.5

SOIL DETAILS :

Density of Soil = g =
Depth of foundation below G.L = H =

3
1.7 T/m
2.0 m

2.00
X

MATERIAL CONSTANT :

M - 20 N/mm2
Fe - 415 N/mm2
1.5

Concrete Grade =
R/f Grade =
Load Factor = gf =

2.00
Z

DESIGN FORCES :

Axial load = P =
Self Weight of Footing =

25.00 T
5.00 T

2.00

Total Vertical Load =

30.00 T

Moment along Major axis


Moment along Minor axis

5 T-m
5 T-m

PRESSURE CALCULATION :

SBC =
20 T/m2
1.25 x
FOR EARTHQUAKE CONDITION ALLOWABLE S.B.C =

P=

P
A

+
-

Mx
Zx

+
-

\ Pmax =

7.50 +

3.75 +

3.75 =

15.00

T/m2

\ Pmin =

7.50 -

3.75 -

3.75 =

0.00

T/m2

20 =

25 T/m2

Mz
Zz

< S.B.C

SAFE

TENSION NOT CREATED

R/F CALCULATION FROM BENDING CONSIDERATION :

2000

765

2000

470
470
765

0.0
T/M2

15.0
T/M2

MOMENT AT CRITICAL SECTION ALONG WIDTH :

M = Pmax x 0.765 x 0.765 / 2


M=
4.39 T-m
Mu =
65.84 KN-m
2
Ast =
413.30 mm
( To be distributed in 2 m Length )
2
Min Req =
600 mm
( Ast = 0.12 x b x D )
Required Spacing of Bar = 12 # @ 185 C/C ALONG WIDTH
PROVIDE 12 # @ 150 C/C ALONG WIDTH
\ Ast =

753.98

mm2

MOMENT AT CRITICAL SECTION ALONG LENGTH :

M = Pmax x 0.765 x 0.765 / 2


M=
4.39 T-m
Mu =
65.84 KN-m
2
Ast =
413.30 mm
( To be distributed in 2 m Length )
2
Min Req =
600 mm
( Ast = 0.12 x b x D )

PROVIDE 12 # @ 185 C/C ALONG LENGTH


\ Ast =

611.34

mm2

CHECK FOR ONE WAY SHEAR ALONG LENGTH :


Critical Section is at diatance of ' d ' from face of column

0.765
2.00

0.765

0.315

2.00
\ Shear force at critical section =
V =
\ Actual Shear stress tv =

=
=
Pt =

tc

100 x As
b x d

0.28
<

N / mm2

tv
HENCE SAFE

15.00 x
4.73

0.315
T

Vu
bxd
1.5 x
1000 x
0.158
100 x
1000 x

4.73
450

x 10000

N / mm2
611.34
450

0.14

Pt
0.15
0.2

tc
0.28
0.33

CHECK FOR ONE WAY SHEAR ALONG WIDTH :


Critical Section is at diatance of ' d ' from face of column

0.765
2.00

0.765

0.315
2.00
\ Shear force at critical section =
V =
\ Actual Shear stress tv =
=
=
Pt =
\

tc

100 x As
b x d

0.28
<

=
N / mm2

tv
HENCE SAFE

15.00 x
4.73

0.315
T

Vu
bxd
1.5 x
1000 x
0.158
100 x
1000 x

4.73
450

x 10000

N / mm2
753.98
450

0.17

CHECK FOR TWO WAY SHEAR :


Critical Section is at distance of 'd/2' from face of column
2.00

0.92
2.00

0.92

d/2
d/2

\ Shear force at Critical Section =


=
=
Critical Perimeter =
=

2 x

15.00 x

Area of Shadeded Portion

15.00 x

3.1536

47.30 T
0.92

2 x

3.68 m

\ Actual Shear stress tv =

Vu
bxd

1.5 x
47.30
3680.00 x
450

0.428

( CLAUSE 31.3.3 IS 456 : 2000 )

where,
ks = ( 0.5+b )
Short Side of Column = 0.47
Long Side of Column = 0.47

ks = 1.50

but not greater than 1.0

x 10000

N / mm2

Allowable Shear stress = ks.tc

b=

0.92

1.00

Where,

tc = 0.25 fck
tc = 0.25 M - 20

Allowable Shear stress = ks.tc =

1.12

1.12

N/mm2

N/mm2

SAFE

CHECK FOR OVERTURNING :


ALONG LENGTH :
Rm

Restoring Moment =
Rm =
Applied Moment =

F.O.S. =
P

25.00

x 1.00

25.00

T.m

5.0

T.m

Restoring Moment
Applied Moment
25.00
5

=
>

5.00
2.2
SAFE

1.00