PCB

PARAMETRIZATION

Instructions for SERVICE


UPDATES:
20/08/2012 2edition PCB software version V3.5.0-89 or higher

CONTENTS

CONTROL PANEL MENU .................................................................................................................................... 3


1.1

ENGINEER MENU............................................................................................................................................ 3

PARAMETER LIST ................................................................................................................................................ 4

ERROR LIST ......................................................................................................................................................... 28

GAS ADAPTIVE SYSTEM .................................................................................................................................. 33

FAULT FINDING ................................................................................................................................................... 34

BURNER PHASE (FAULT HISTORY) .............................................................................................................. 54

CONTROL PANEL MENU

The following procedure is used to access the four boiler pro- gramming menus:
from the main menu
C;

A e C for approx. 6 seconds;

B to see menus 1 - 2 - 3 - 4;

B to confirm the selected menu;

C to go back one menu at a time to the main menu.

The four menus are:


1 ENDUSER
2 COMMISSIONING
3 ENGINEER
4 OEM

1.1

(visible pressing the button C)


(visible with a buttons combination)
(visible only with PASSWORD 10101)
(visible only with PASSWORD)

ENGINEER menu

Access Engineer menu as described in section 1.


This level includes all parameters present on Enduser and Commissioning menus.
The details of this menu are given in next section.
Some menus are avaible only if the system is correctly configured (e.g. solar menu).
The parameters with grey underlight are different default values depending on boiler
model.

PARAMETER LIST
Parameter

Level
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Parameter
1
2
3
5
6

Parameter

INFORMATION
Room temperature
Room temperature min
Room temperature max
Boiler temperature
Outside temp
Outside temp min
Outside temp max
Instant HW heater temp
State central heating CH1
State central heating CH2
State central heating CH3
State hot water
State boiler
State SithermPro
Telephone customer service

Level
1

Change Language

24

Lighting

26

Operation lock

27

Programming lock

29

Units

40

Used as

42

Assignment device 1

43

Action operation

54
70

2
2

Readjustment room sensor


Software version

120
121
130

Only with LMS15 pcb

Level
2
2
2

SET TIME AND DATE

Default

OPERATOR SECTION

Default

Hours / minutes
Day / month
Year
Start of summertime
End of summertime

20

Parameter

Displayed if the heating circuit is activated


Displayed if the heating circuit is activated

Level
1
1
1
3
3

Default

Displayed if the control panel is configured as room unit


Displayed if the control panel is configured as room unit
Displayed if the control panel is configured as room unit

Off
Temporarily
Permanently
On
Off
On
Off
1 C , bar
2 F , PSI
Operator unit 1
Room unit 1
Room unit 2
Room unit 3
Temps / mode CH1
Central heating 1 and 2
Central Heating 1 and 3
All central heatings
0 Locally
1 Centrally
-3C+3C

Block of the control panel buttons A e B


The parameters can be displayed but not changed

The control panel is installed in the boiler


The control panel is configured as room unit of heating circuit 1
The control panel is configured as room unit of heating circuit 2
The control panel is configured as room unit of heating circuit 3
As room unit 1, the action of the respective control panel can be assigned to heating
circuit 1 or to 2 heating circuits.
The room unit controls only the respective heating circuit.
Only room unit 1 can be Centrally. It also controls dhw mode and standby.

WIRELESS
Binding
Test mode
Room unit 1

Activation of wireless link with basic unit


Test mode is used for checking the wireless communication
Check of link

Default

131
132
133
134
135
140

2
2
2
2
2
2

Parameter

Room unit 2
Room unit 3
Outside sensor
Repeater
Operator unit
Delete all devices

Check of link
Check of link
Check of link
Check of link
Check of link

Level

TIME CENTRAL HEATING 1 2 3

1
500
514
501
502
503
504
505
506

2
520
534
521
522
523
524
525
526

3
540
554
541
542
543
544
545
546

Select days

Selection of days or groups of days for time program

1
1
1
1
1
1
1

Select default timings?


1st Time ON
1st Time OFF
2nd Time ON
2nd Time OFF
3rd Time ON
3rd Time OFF

Is it possibile to select up to 3 preselect time programs

516

536

556

Default values

Parameter

Yes
No

Level

TIME HOT WATER

560
574
561
562
563
564
565
566

1
1
1
1
1
1
1
1

Select days
Select default timings?
1st Time ON
1st Time OFF
2nd Time ON
2nd Time OFF
3rd Time ON
3rd Time OFF

576

Default values

Parameter

Yes
No

TIME AUXILIARY

1
1
1
1
1
1
1
1

Select days
Select default timings?
1st Time ON
1st Time OFF
2nd Time ON
2nd Time OFF
3rd Time ON
3rd Time OFF

616

Default values

Parameter

Level

Default

Selection of days or groups of days for time program


Is it possibile to select up to 3 preselect time programs

Level

600
614
601
602
603
604
605
606

Default

Default

Selection of days or groups of days for time program


Is it possibile to select up to 3 preselect time programs

Yes
No

HOLIDAY HEATING 1 2 3

1
641
642
643

2
651
652
653

3
661
662
663

Select

Is it possibile to select up to 8 holiday periods

1
1

Start
End

648

658

668

Operating level

Day and month of holiday start


Day and month of holiday end
Off
Reduced

Default

Parameter
CR1

CR2

CR3

700

1000

1300

710
712
714
716

1010
1012
1040
1016

720
721

Level

TEMPS / MODE 1 2 3

Operating mode

1310
1312
1314
1316

1
1
2
3

Comfort setpoint
Reduced temp setpoint
Frost protection setpoint
Room temp setpoint max

1020

1320

Heating curve slope

1021

1321

Heating curve displacement

726

1026

1326

Heating curve adaption

730

1030

1330

Summer/winter heating limit

732

1032

1332

24-hour heating limit

740
741
742
746

1040
1041
1042
1046

1340
1341
1342
1346

2
2
2
2

Flow temp setpoint min


Flow temp setpoint max
Flow temp setpoint room stat

750

1050

1350

Room influence

760
770

1060
1070

1360
1370

2
3

Room temp limitation


Central heating boost

780

1080

1380

Quick setback

790

1090

1390

Optimum start control max

791

1091

1391

Optimum stop control max

800

1100

1400

Reduced setp increase start

801

1101

1401

Reduced setp increase end

809

1109

1409

Continuous pump operation

830

1130

1430

Mixing valve boost

832

1132

1432

Actuator type

The control panel is installed in the boiler:


0 Off
Heating is disabled
1 Timed
Heating depends on the set time band
2 Reduced
Heating is disabled
3 On
Heating is always enabled
The control panel is installed on the wall:
0 Off
The boiler starti when the room temperature falls below frost protection setpoint
1 Timed
Heating depends on the set time band
2 Reduced
The temperature of the room to heat is reduced
3 On
The temperature of the room to heat is comfort

Max room temperature settable


The heating curve generates the flow temperature setpoint, which is used to maintain a certain flow temperature level
depending on the prevailing weather conditions
Parallel displacement of the heating curve
Adaption of the heating curve is used by the controller to automatically adapt the
1 On
0 Off
heating curve to the prevailing weather conditions.
With outside sensor and in Automatic operation,the function is used to switch the heating on and off in the course of
the year, depending on the outside temperature.
--- = disabled
The heating is switched off when the Outside temp is at the same level of room temperature setpoint + the parameter
732. The function is deactivated in Comfort mode
Min value of flow temperature setpoint
Max value of flow temperature setpoint
Flow temperature setpoint when using room unit. Set the value --- to have the flow temperature modulation.
Delay time in case it is used an external electrical valve zone
Weight of room temperature and Outside temperature for the flow temperature calculation:
---%: weather compensation alone
199%: weather compensation with room influence
100%: room compensation alone
Differential to swich off the heating depending on the room temperature setpoint
Temporary boost of room temperature setpoint. With room temperature near the setpoint, the value becomes zero
Off
The heating circuit pump is deactivated and, in the case of mixing valve circuits,
Down to reduced setpoint
the mixing valve is fully closet.
Down to frost prot setpoint
The change from one temperature level to the other is optimized in a way that the Comfort setpoint is reached at the
respective switching time
The change from one temperature level to the other is optimized in a way that the Comfort setpoint minus C is
reached at the respective switching time
Below this value of outside temperature the Reduced setpoint is linearly increased up to Comfort setpoint.
--- = disabled
At this value of outside temperature the Recuded setpoint is equal to Comfort setpoint
Yes
The heating 6empera pump/boiler pump always keeps running
No
To ensure proper flow temperature control via the mixing valve, the current flow temperature must be higher than the
flow temperature setpoint demanded for the mixing valve
2-position
One relay with 2 contact (NO and NC)
3-position
Two relays, one to close and one to open

Default

On

20C
16C
6C
35C
1,5
0C
On
----25C
80C
80C
0s
50%
0,5C
5C
Down to
reduced
setpoint
00:00
00:00
---15C
No
2C
3-position

833
834

1133
1134

1433
1434

3
2

Switching differential 2-pos


Actuator running time

850

1150

1450

Floor curing function

851
855
856

1151
1155
1156

1451
1455
1456

2
2
2

Floor curing setp manually


Floor curing setp current
Floor curing day current

861

1161

1461

Excess heat draw

870

1170

1470

With buffer

872

1172

1472

With prim contr/system pump

898

1198

1498

Operating level changeover

900

1200

1500

Optg mode changeover

Parameter

Level

Only with 2 points actuator


Set the running time of the actuator used with the mixing valve
Floor curing function:
Function disable
Off
Functional heating
7 days on, 3 days with Tflow of 25C and 4 days with Tflow of 55C
Curing heating
18 days on, 6 day with Tflow daily increase of 5C from 25C to 55C, 6 days with
Tflow of 55C, 6 days with Tflow daily decrease of 5C from 55C to 25C
Functional/curing heating
First Functional heating then Curing heating
Curing/functional heating
First Curing heating then Functional heating
Manually
The floor setpoint is controller maually
Flow temperature set manually to run the function
Actual flow temperature during function operation. With --- the function is disabled
Week day ana durante function operation. With --- the function is disabled
Excess heat draw from a external boiler or solid fuel boiler:
Disabled
Off
Drawing on heating space only when the controller is in Heating mode
Heating mode
Always
Drawing on heating space in all operating modes
If there is a buffer storage tank, select if heating circuit can draw heat from it:
Yes
No
Heating circuit receives heat from primay controller or with the help of the system pump:
Yes
No
The operating level shall be switched via an external time switch and inputs Hx:
Off
Reduced
On
The heating circuit can be forced to adopt a selectable operating mode via input H by actuating a contact:
None
Off
Reduced
On
Timed

COOLING CIRCUIT 1

901

Operating mode

904
932

2
2

Protection setpoint
Room temp limitation

Parameter

Level

1600

Operating mode

1610
1612

1
2

Hot water temp setpoint


Reduced temp setpoint

1620

Release

Activation of the function:


Off
Timed
Cooling switch on when the room temperature exceeds this level + parameter 932
Offset for cooling switching on

TEMPS / MODE HOT WATER


Nominal setpoint
On
Setpoint equal to DHW frost protection setpoint
Off
Eco
Preheat disabled
DHW Setpoint during release times
Backup setpoint outside release times
Time program release:
Enabled 24h/day
0 24h/day
The same time program of heating circuits
1 Time setting central heating
2 Time hot water
DHW time program

2C
30s

Off

25C

Always

Yes
Yes

Reduced

Off

Default
Off
40C
1C

Default
On
60C
35C
Table1

Charging priority of tank:


Absolute
Shifting
1630

Charging priority

1640

Legionella function

1641
1642
1644
1645
1646

2
2
2
3
3

Legionella funct periodically


Legionella funct weekday
Legionella funct time
Legionella funct setpoint
Legionella funct duration

1647

Legionella funct circ pump

1660

Circulating pump release

1661

Circulating pump cycling

1663

Circulation setpoint

1680

Optg mode changeover

Parameter

Level

1909

1959

Flow temp setp cons request

1875

1925

1975

Excess heat draw

1878

1928

1978

With buffer

1880

1930

1980

With prim contr/system pump

Level

2055
2056

2
3

0 Off
1 Periodically
2 Fixed weekday
Number of weekdays after which the function shall be activated again
Select the weekday the function shall be performed
The Legionella function is started at the set time
Storage tank setpoint during the function
The demanded Legionella funct setpoint must be fully maintained during the set dwelling time
Activation of DHW circutating pump during the legionella function:
On
Off
Release of circulating pump:
Time setting central heating
Hot water release
Time hot water
Time auxiliary
The circulating pump can be controlled in cycling mode:
on 10 minutes, off 20 minute
On
Off
When using a circulation sensor, the circulating pump is activated whenever the temperature falls below the circulation
value
In the case of external changeover via inputs Hx, the operating mode where changeover is to take place can be
selected:
Function disabled
None
On
Off

CONSUMER CIRCUIT 1 2 SWIMMING POOL

1859

Parameter

None
MC shifting, PC absolute

Heating circuits tay locked until DHW heating is completed


If the capacity of the heat source is not sufficient, the mixing and pump heating
circuits will be restricted until the DHW is heated up
Space heating and DHW heating take place at the same time
The pump heating circuits stay locked until the DHW storage tank is heated up. If
the capacity of the heat source is not sufficient, the mixing heating circuits will be
restricted also

Setpoint solar heating


Setpoint source heating

Set the flow temperature setpoint that becomes active when there is a request for heat from the consumer circuit or
swimming pool circuit
Excess heat draw trought the consumer circuit or swimming pool circuit:
On
Off
If a buffer storage tank is used to supply consumer circuit or swimming pool circuit:
On
Off
The consumer circuit or the swimming pool circuit shall receive heat via the primary controller or the system pump:
On
Off

Absolute

Off
7
Monday
--65C
10min
On
Hot water
release

On
45C

None

Default
70C
On
On
On

SWIMMING POOL

Default

When making use of solar energy, the swimming pool is heated to this setpoint
When using other heat sources, the swimming pool is heated to this setpoint

30C
22C

2065

Charging priority solar

2080

With solar integration

Parameter
2150

Parameter

Level
3

Charging priority of swimming pool with solar energy:


Yes
No
The setting made here decides whether the swimming pool can be heated by solar energy:
Yes
No

PRIMARY CONTR/SYSTEM PUMP


Primary contr/system pump

Level

If the plant is equipped with a buffer storage tank, it must be entered here whether the primary controller or the system
pump is located upstream of or downstream from the buffer storage tank:
Before buffer
After buffer

BOILER

2203

Release below outside temp

2208

Full charging buffer

2210
2212
2214
2237
2238
2243
2245
2250

3
3
2
3
3
3
3
3

Setpoint min
Setpoint max
Setpoint manual control
Int action time Tn HW
Der action time Tv HW
Burner off time min
SD burner off time
Pump overrun time

2301

Boiler pump on heat gen lock

2305

Impact heat generation lock

2316

Temp differential max

2317
2330
2331
2441

3
3
3
2

Temp differential nominal


Output nominal
Output basic stage
Fan speed heating max

2454

Switching diff on CHs

2455

Switching diff off min CHs

2456

Switching diff off max CHs

2457

Settling time HCs

2460

Switching diff on HW

2461

Switching diff off min HW

2462

Switching diff off max HW

The boiler can be released depending on the outside temperature


It ispossible to switch off released heat sources only when the buffer storage tank is fully charged:
On
Off
Min value of flow temperature setpoint
Max value of flow temperature setpoint
In Manual control mode, the common flow temperature setpoint can be set to a fixed value.
Integral part of DHW modulation
Derivative part of DHW modulation
The minimum burner off time acts exclusively between successive startup cycles resulting from space heating requests
Actual and Setpoint flow temperature different over that the Burner off time min' is stopped
Pump overrun time after heat request
Activation of boiler pump when the Heat generation lock is actived:
On
Off
When is active the function Heat generation lock:
Heating mode only
Heating and HW mode
Maximum boiler temperature differential used to control the speed pump:
--- = disabled
Nominal boiler temperature differential (flow return) used to control the speed pump
Maximum output power in central heating
Minimum output power in central heating
Fan speed at maximum central heating
The switch-on threshold is calculated from the required setpoint minus the switch-on differential used for requests from
space heating
The switch-off threshold minimum is calculated from the required setpoint plus the switch-off differential used for
requests from space heating
The switch-off threshold maximum is calculated from the required setpoint plus the switch-off differential used for
requests from space heating
Validity time of parameter 2456
The switch-on threshold is calculated from the required setpoint minus the switch-on differential used for DHW
requests
The switch-off threshold minimum is calculated from the required setpoint plus the switch-off differential used for DHW
requests
The switch-off threshold maximum is calculated from the required setpoint plus the switch-off differential used for DHW
requests

Yes
Yes

Default
After buffer

Default
--On
25C
90C
80C
Table1
0s
3min
20C
3min
Off
Heating and
HW mode
--20C
Table1
Table1
Table1
5C
5C
10C
1min
0C
10C
10C

2463

Settling time HW

2670

Parameter

2672
2675
2681
2682

3
3
3
3

Parameter
Parameter
Parameter
Parameter

Parameter

3
3
3
3

Ion current filtered


Position stepper motor
Learning value gas quality
Operating phase

2720

Release sel type of gas

2721

Type of gas

2725

Sel individual boiler setting

2726
2729

3
3

Ind boil setting ion curr LF


Ind boil setting ion curr HF

2740

Triggering drift test

2741
2742
2743
2744
2745
2746
2747
2748
2749

3
3
3
3
3
3
3
3
3

Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Parameter
Reset drift test

3510

SITHERM PRO

Default

Ionization current actual value


Gas valve stepper motor position
Gas calorific power measurement
Release of ga type selection:
0 Off
1 On
Type of gas:
1 Natural gas
2 Liquefied gas
Activation of combustion adjustment:
Off
Set low-fire ion current
Activation of correction at low power
Save low-fire ion current
Stored of correction at low power
Set high-fire ion current
Activation of correction at high power
Save high-fire ion current
Stored of correction at high power
Setting of correction at low power
Setting of correction at high power
Manual test of combustion adjustment:
0
Disabled
1
Test done at high and low power
2
Test done only at high power
3
Test done only at low power
4
Test done at high and low power alternatively for 3 times
Last test result at low power
Last test filtred result at low power
Correction at low power
Threshold of correction at low power
Last test result at high power
Last test filtred result at high power
Correction at high power
Threshold of correction at high power
Reset of correction results

CASCADE
Lead strategy

On

Precirculation time on DHW way (3WV position) during precirculation function


Precirculation time on CH way (3WV position) during precirculation function

Level
3

1min

30C
Table1
Table1
Table1

Level

2700
2702
2703
2706

Parameter

Validity time of parameter 2462


Activation of Super Over Temperature Function (SOT):
On
Off
Increase of boiler setpoint for the control of SOT

Lead strategy:

Off
Natural gas

Off

0uA
0uA

No
Default
Late on, late off

Late on, early off


Late on, late off

smallest possibile number of boilers are in operation, or additional boilers operate


with short on times
Smallest possible number of switch-on/off actions for the boilers

Early on, late off

3511
3512
3530
3531
3532
3533
3534

3
3
3
3
3
3
3

Output band min


Output band max
Release integral source seq
Reset integral source seq
Restart lock
Switch on delay
Forced time basic stage

3540

Auto source seq ch'over

3541

Auto source seq exclusion

3544
3560

3
3

Leading source
Return setpoint min

Parameter

Level

Largest possibile number of boilers are in operation, or additional boilers operate


with the longest possibile on times
Minimum power percentual of use of boiler
Maximum power percentual of use of boiler
Temperature gradient (increase) when is necessary more power
Temperature gradient (decrease) when is necessary less power
Minimum lock time from two consecutive ignition
Delay of switch on of boiler for heat request to prevent too frequency switching action
When switched on, every boiler operates with its basic stage for the period of time set here
Heat source sequence option:
--- fixed order, the lead boiler can be selected by the parameter 3544 and the other boilers are then switched on and off
in the same order as the LPB device addresses.
0990 hours: After that time, the boiler with the following address of the leader become leader.
Exclusion of boile from the ignition sequence:
The order of switching on the boilers changes when the set number of operating
None
hours are reached (parameter 3540).
First
The first boiler (address) remains the leader. The order of the othe rboilers
changes when the set number of operating hours are reached (parameter 3540).
Last
The last boiler (address) remains the last. The order of the othe rboilers changes
when the set number of operating hours are reached (parameter 3540).
First and last
The first boiler (address) remains the leader. The last boiler (address) remains the
last. The order of the othe rboilers changes when the set number of operating
hours are reached (parameter 3540).
Choice of the leader (source 116)
Minimum Setpoint value of return temperature

SOLAR

3810
3811

2
2

Temp diff on
Temp diff off

3812

Charg temp min HW st tank

3815

Charging temp min buffer

3818

Charging temp min swi pool

3822

Charging prio storage tank

3825

Charging time relative prio

3826

Waiting time relative prio

3827

Waiting time parallel op

3828

Delay secondary pump

Minimum differential temperature between solar collector probe and solar DHW tank for the activation of solar pump
Maximum differential temperature between solar collector probe and solar DHW tank for the deactivation of solar pump
Minimum charging temperature of solar DHW tank.
--- = disabled
Minimum solar collector temperature for the deactivation of collector pump.
--- = disabled
Minimum solar collector temperature for the swimming pool charging.
--- = disabled
If a plant uses several heat exchangers, it is possible to set a priority for the integrated storage tanks, which defines the
charging sequence:
None
Hot water storage tank
Buffer storage tank
If the preferred storage tank cannot be charged , the priority is transferred to the next storage tank or the swimming
pool for the set period oftime:
--- = disabled
Waiting time for the activation of priority charging
Waiting time before charging of more than one storage tanks simultaneously:
--- = disabled
Delay for activation of secondary pump

40%
90%
50C*min
20C*min
180s
3min
60s
500h

None

1
8C

Default
8C
4C
------Hot water
storage tank

--5min
--60s

3830

Collector start function

3831

Min run time collector pump

3840

Collector frost protection

3850

Collector overtemp prot

3860

Evaporation heat carrier

3880

Antifreeze

3881
3884

3
3

Antifreeze concentration
Pump capacity

3887

Pulse unit yield

Parameter

Level

4102

Locks other heat sources

4110

Setpoint min

4130
4131

3
3

Temp diff on
Temp diff off

4133

Comparative temp

Parameter

If the collector temperature cannot be correctly acquired because the pump is not running (especially in the case of
vacuum tubes), the pump can be activated from time to time.
--- = disabled
Minimum running time of collector pump
When there is risk of frost at the collector, the collector pump is activated to prevent it.
--- = disabled
If there is a risk of overtemperature at the collector, storage tank charging is continued to reduce the amount of surplus
heat
If there is a risk of evaporation of the heat conducting medium due to high collector temperatures, the collector pump is
deactivated
Type of antifreeze:
None
Ehtylen glycol
propylen glycol
Ethyl and propyl glycol
The type of antifreeze used and its concentration must be entered, thus allowing calculation f the energy yield
The pumps flow rate in l/h must be determined and serves for calculating the volumetric flow
Defines the flow rate per pulse for the selected input Hx. For that purpose, the respective input Hx must be configured
for counting pulses

SOLID FUEL BOILER

Level

Parameter to lock the other heat source:


On
Off
The boiler pump is put into operation only when the boiler temperature reaches a minimum level, in addition to the
required temperature differential (parameters 4130 and 4131)
The boiler pump is activated if the boiler temperature exceeds the minimum setpoint by the switching differential
The boiler pump is deactivated if the boiler temperature lies below the minimum setpoint
Sensor used with sensor B22 to calculate the differentials 4130 e 4131:
Hot water sensor B3
DHW storage tank (upper)
Hot water sensor B31
DHW storage tank (lower)
Buffer sensor B4
Buffer storage tank (upper)
Buffer sensor B41
Buffer storage tank (lower)
Flow temp setpoint
setpoint of common flow
Setpoint min
minimum Setpoint (fixed value)

BUFFER STORAGE TANK

4720

Auto generation lock

4722
4724
4750
4755

3
3
3
3

Temp diff buffer/CH


Min st tank temp heat mode
Charging temp max
Recooling temp

4756

Recooling HW/CHs

Sensor used for buffer temperature control:


None
With B4
Buffer storage tank (upper)
With B4 and B42/B41
Buffer storage tank (upper), Buffer storage tank (middle) / Buffer storage tank
(lower)
Temperature difference between buffer and heating circuit over there the heat request is carried out by buffer
Minimum buffer temperature to perfom the heat request
Maximum charging temperature from solar collectors
Recooling temperature for buffer
Buffer recooling through heating circuit or dhw tank:
On
Off

--30s
--120C
140C

None
30%
200l/h
10l

Default
On
40C
8C
4C

Setpoint min

Default

With B4

0C
--80C
60C
Off

4757

Recooling collector

4783

With solar integration

4790
4791

3
3

Temp diff on return div


Temp diff off return div

4795

Compar temp return div

4796

Optg action return diversion

4800

Partial charging setpoint

4810

Full charging

4811

Full charging temp min

4813

Full charging sensor

Parameter

Level

5010

Charging

5020
5021

3
3

Flow setpoint boost


Transfer boost

5022

Type of charging

5024
5030

3
3

Switching diff
Charging time limitation

Buffer recooling through solar collector:


Off
Summer
Always
Charging buffer from solar collector:
Yes
No
Temperature differential On for diverting valve (using common return sensor B73)
Temperature differential Off for diverting valve (using common return sensor B73)
Buffer sensor with which the return temperature is compared:
Buffer storage tank (upper)
With B4
Buffer storage tank (lower)
With B41
With B42
Buffer storage tank (middle)
Function selected for return temperature:
Temp decrease
If the consumers return temperature is higher than the temperature at the selected
sensor, the return temperature can be used to preheat the lower storage tank
section.
Temp increase
If the consumers return temperature is lower than the temperature at the selected
sensor, the return temperature can be raised by diverting the return through the
lower storage tank section.
Charging buffer setpoint if the buffer is hydraulically decoupled.
--- = disabled
Function enables released heat sources to switch off only when the buffer storage tank is fully charged:
Disabled
Off
Charging enabled only with heat request on
Heating mode
Always
Charging enabled also after heat request
Minimum charging temperaturer
Sensor used for full charging:
Buffer storage tank (upper)
With B4
With B42/B41
Buffer storage tank (upper), Buffer storage tank (middle) / Buffer storage tank
(lower)

HOT WATER STORAGE TANK


Hot water tank charging only when DHW release is set in accordance with the heating circuits time programs:
Once/day
Several times/day
The DHW request to the boiler is made up of the current DHW setpoint plus the adjustable charging boost.
Temperature diffferential between heating buffer and hot water tank to transfer heat to hot water tank
Charging modes:
Recharging
The DHW request is always controlled by sensor B3 (upper) at the top.
Full charging
The DHW request is always controlled by sensor B3 (upper) and B31 (lower).
Full charging legio
When the Legionella function is activated, the DHW request is always controlled
by both storage tank sensors B3 und B31, otherwise only by sensor B3 at the top.
Full charg 1st time day
When charging is effected for the first time in the morning, the DHW request is
controlled by both storage tank sensors B3 and B31, otherwise only by sensor B3
at the top.
Full charg 1st time legio
When charging is effected for the first time in the morning and the Legionella
function is activated, the DHW request is controlled by both storage tank sensors
B3 and B31, otherwise only by sensor B3 at the top.
If the DHW temperature is lower than the current setpoint minus the switching differential, DHW charging is started
Temporal limitation of DHW charging

Off

No
10C
5C
With B42

Temp increase

--Off
8C
With B42/B41

Default
Several
times/day
Table1
8C

Recharging

5C
150min

5040

Discharging protection

5050
5051
5055

3
3
3

Charging temp max


Storage tank temp max
Recooling temp

5056

Recooling heat gen/CHs

5057

Recooling collector

5060

El imm heater optg mode

5061

El immersion heater release

5062

El immersion heater control

5070

Hot water boost

5071

Charging prio time push

5085

Excess heat draw

5090

With buffer

5092

With prim contr/system pump

5093

With solar integration

Parameter

Level

Attivazione della pompa Q3 in caso di temperatura di mandata troppo alta This function ensures that the DHW charging
pump (Q3) is activated only when the heat source temperature is high enough:
Timed
Disabled
Off
Enabled
Always
Timed
Active only if the heat source is not able to supply heat or if it is not available
Maximum charging temperature from solar collector
65C
Maximum hot water tank temperature
90C
Recooling hot water tank temperature
80C
Tank recooling through heating circuit:
On
Off
Off
Tank recooling through solar collector:
Off
Off
Summer
Always
Electric immersion heater used for DHW tank:
The electric immersion heater is only used if the boiler delivers a fault status
Substitute
message or has been shut down via boiler lock.
The electric immersion heater is used when all connected heating circuits have
Summer
Substitute
switched to summer operation. The DHW is again heated by the boiler as soon as
at least one of the heating circuits has switched back to Heating mode. But the
electric immersion heater is also used if the boiler delivers a fault status message
or has been shut down via boiler lock.
Always
DHW is always heated with the electric immersion heater
Electric immersion heater release:
24h/day
Hot water
Hot water release
release
Time hot water
Electric immersion heater control mode:
External thermostat
Hot water sensor
Hot water sensor
If the DHW temperature drops by more than 2 switching differentials (l5024) below the Reduced setpoint:
On
On
Off
The DHW storage tank is charged with absolute priority during the set period of time
0min
Surplus heat can be fed to the DHW storage tank:
On
On
Off
DHW storage tank receives its heat via buffer storage tank:
Yes
No
No
DHW storage tank receives its heat via the primary controller or with
the help of the system pump:
No
Yes
No
DHW storage tank receives its heat from the solar collectors:
Yes
Yes
No

INSTANTANEOUS HW HEATER

Default

5464

Hot water preheat release

5470
5476
5482
5490
5491

1
3
3
3
3

HW preheat time when no CH


Keep hot periodically
Flow switch time cons
Parameter
Parameter

Parameter

Level

5710

Temps / mode CH1

5711

Cooling circuit 1

5715

Temps / mode CH2

5721

Temps / mode CH3

5730

Hot water sensor

5731

HW controlling element

5732
5733

3
3

Pump off change div valve


Delay pump off

5734

Basic pos HW div valve

5736

Hot water separate circuit

5737

Optg action HW div valve

5738

Midposition DHW div valve

5774

Ctrl boiler pump/HW valve

Preheat mode:
24h/day
Hot water release
Time central heating CH3
Time hot water
Time auxiliary
Preheat time
Duration time of preheat function
Minimum response time of the flow switch for detecting consumption

CONFIGURATION
Heating circuit 1 activation:
0 Off
1 On
Cooling circuit 1 activation:
Off
4-pipe system cooling
Heating circuit 2 activation:
0 Off
1 On
Heating circuit 3 activation:
Off
On
DHW sensor selection:
DHW storage tank sensor
1 Hot water sensor B3
Sensor used as DHW thermostat
2 Thermostat
3 HW outlet sensor B38
Instantaneous water heater outlet sensor
Actuator type for DHW request control:
No function
No charging request
Actuator used as charging pump
Charging pump
Diverting valve
Actuator used as diverting valve
Set the time the pumps are deactivated when the diverting valve switches over
Set the delay time for the pumps to be deactivated after the diverting valve has switched over
Default DHW diverting valve position:
Last request
Default for boiler with DHW tank
Central heating
Hot water
Default for instantaneous water heater boiler
The DHW separate circuit can only be employed in a cascaded system:
On
Off
The diverting valve position selected here is the position used when the output is active:
Position on HW
Position on CH
DHW diverting valve can be driven to the mid-position:
On
Off
Activation mode of boiler pump and DHW diverting valve:
All requests
Request CH1/HW only

Time hot water

Table1
Table1
1s
Table1
Off

Default
On
Off
Off
Off

Table1

Diverting valve
0s
0s
Table1

Off
Position on HW
Off
All requests

Actuator configuration in case of solar storage tanks:


Used as charging pump
Charging pump
Diverting valve
Used as diverting valve
In the case of solar plant diagrams with 2 storage tanks, it must be selected whether there is an external heat
exchanger for both the DHW and the buffer storage tank or for only one of them.:
Commonly
Hot water storage tank
Buffer storage tank
Functions specific to combi storage tanks are activated via this setting (for example, the electric immersion heater
installed in the buffer storage tank can be used for both space heating and DHW heating):
Yes
No
0 None
1 Circulating pump Q4
DHW circulating pump
2 El imm heater HW K6
3 Collector pump Q5
Solar collector pump
4 Cons circuit pump VK1 Q15
Consumer circuit 1 pump
5 Boiler pump Q1
Boiler pump
6 Bypass pump Q12
7 Alarm output K10
Alarm relay signals faults
8 2nd pump speed CH1 Q21
9 2nd pump speed CH2 Q22
10 2nd pump speed CH3 Q23
11 heating pump CH3 Q20
Pump/zone valve for heating circuit 3
12 Cons circuit pump VK2 Q18
13 System pump Q14
Pump activated at every heat request from consumer circuits
14 Heat gen shutoff valve Y4
15 Solid fuel boiler pump Q10
Solid flue boiler pump
16 Time setting 5 K13
The relay is controlled according to setting made in time auxiliary program
17 Buffer return valve Y15
18 Solar pump ext exch K9
19 Solar ctrl elem buffer K8
20 Solar ctrl elem swi pool K18
Contact to heat swimming pool by solar (in case of several heat exchangers)
22 Swimming pool pump Q19
25 Cascade pump Q25
Common cascade pump
26 St tank transfer pump Q11
27 Hot water mixing pump Q35
28 HW interm circ pump Q33
29 Heat request K27
30 Refrigeration request K28
Cooling request from cooling circuit 1
33 Heating pump CH1 Q2
Pump/zone valve for heating circuit 1
34 Heating pump CH2 Q6
Pump/zone valve for heating circuit 2
35 Hot water ctrl elem Q3
Pump/diverting valve for DHW tank
36 Instant WH ctrl elem Q34
Pump/diverting valve for instantaneous DHW production
38 Water refill K34
Water refill electrovalve
39 2nd boiler pump speed Q27
2nd boiler pump speed
40 Status output K35
41 Status information K36
42 Flue gas damper K37
43 Fan shutdown K38
External fan control

5840

Solar controlling element

5841

External solar exchanger

5870

Combi storage tank

5890

Relay output QX1

5891

Relay output QX2

See relay output QX1

5892

Relay output QX3

See relay output QX1

Charging pump

Commonly

No

heating pump
CH1 Q2

Boiler pump
Q1
Table1

5931

5932

Sensor input BX2

Sensor input BX3

5950

Function input H1

5951

Contact type H1

0 None
1 Hot water sensor B31
2 Collector sensor B6
4 HW circulation sensor B39
5 Buffer sensor B4
6 Buffer sensor B41
7 Flue gas temp sensor B8
8 Common flow sensor B10
9 Solid fuel boiler sensor B22
10 HW charging sensor B36
11 Buffer sensor B42
12 Common return sensor B73
13 Cascade return sensor B70
14 Swimming pool sensor B13
16 Solar flow sensor B63
17 Solar return sensor B64
19 Primary exch sensor B26
See sensor input BX2
0 None
1 Optg mode change CHs+HW
2 Operating level HW
3 Optg mode changeover CHs
4 Optg mode changeover CH1
5 Optg mode changeover CH2
6 Optg mode changeover CH3
7 Heat generation lock
8 Error/alarm message
9 Consumer request VK1
10 Consumer request VK2
11 Release swimming pool
12 Excess heat discharge
13 Release swi pool solar
14 Operating level HW
15 Operating level CH1
16 Operating level CH2
17 Operating level CH3
18 Room thermostat CH1
19 Room thermostat CH2
20 Room thermostat CH3
21 Hot water flow switch
22 Hot water thermostat
24 Pulse count
28 Checkb sign flue gasdamper
29 Start prevention
31 Boiler flow switch
32 Boiler pressure switch
50 Flow measurement Hz
51 Consumer request VK1 10V
52 Consumer request VK2 10V
53 Consumer request VK3 10V
54 Pressure measurement 10V
58 Preselected output 10V
NO

DHW storage tank (lower)


Solar collector sensor
DHW circutaing sensor
Buffer storage tank (upper)
Buffer storage tank (lower)
Common flow sensor (cascade)
Solid flue boiler sensor

None

Buffer storage tank (middle)


Return cascade sensor
Swimming pool sensor
Solar flow sensor for yield measurement
Solar return sensor for yield measurement
None
Mode changing of heating circuits and DHW circuit
Mode changing of DHW circuit
Mode changing of heating circuits
Mode changing of heating circuit 1
Mode changing of heating circuit 2
Mode changing of heating circuit 3
Heat requests and burner locked (frost protection enabled)
Alarm signal
Consumer request 1
Consumer request 2
Swimming pool request
External heat sources for excess heat
Release swimming pool heating from solar collector
Mode changing of DHW circuit
Mode changing of heating circuit 1
Mode changing of heating circuit 2
Mode changing of heating circuit 3
Room thermostat request for heating circuit 1
Room thermostat request for heating circuit 2
Room thermostat request for heating circuit 3
DHW flow switch control
DHW thermostat control
Pulse counter
Flue gas damper signal
To avoid burner start
Request by flow switch
Request by switch
Flow frequency measurement
Consumer request 1 by 0-10V signal
Consumer request 2 by 0-10V signal
Consumer request 3 by 0-10V signal
Pressure measurement by 0-10V signal
Selection of boiler power by 0-10V signal

Pressure
measurement
10V

NO

5953
5954
5955
5956
5970

3
3
3
3
2

Voltage value 1 H1
Function value 1 H1
Input value 2 H1
Function value 2 H1
Function input H4

5971

Contact type H4

5973
5974
5975
5976

2
2
2
2

Voltage value 1 H4
Function value 1 H4
Input value 2 H4
Function value 2 H4

NC
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
See function input H1
NO
NC
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor

5977

Function input H5

See function input H1

5978

Contact type H5

6020

Function extension module 1

6021
6022

2
2

Function extension module 2


Function extension module 3

6024

Funct input EX21 module 1

6026
6028
6030
6031
6032
6033
6034
6035
6036
6037
6038
6040
6041
6042
6043
6044
6045
6046

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Funct input EX21 module 2


Funct input EX21 module 3
Relay output QX21 module 1
Relay output QX22 module 1
Relay output QX23 module 1
Relay output QX21 module 2
Relay output QX22 module 2
Relay output QX23 module 2
Relay output QX21 module 3
Relay output QX22 module 3
Relay output QX23 module 3
Sensor input BX21 module 1
Sensor input BX22 module 1
Sensor input BX21 module 2
Sensor input BX22 module 2
Sensor input BX21 module 3
Sensor input BX22 module 3
Function input H2 module 1

6047

Contact type H2 module 1

6049
6050

2
2

Voltage value 1 H2 module 1


Funct value 1 H2 module 1

NO
NC
0 None
Manual input/output configuration
1 Multifunctional
2 Temps / mode CH1
Mixing circuit 1 configuration
3 Temps / mode CH2
Mixing circuit 2 configuration
4 Temps / mode CH3
Mixing circuit 3 configuration
5 Return temp controller
Not used
6 Solar HW
Solar plant cofiguration (2 sensors and solar pump)
7 Primary contr/system pump
Not used
See function extension module 1
See function extension module 1
0 None
25 Limit thermostat CH
See funct input EX21module 1
See funct input EX21module 1
See relay output QX1
See relay output QX1
See relay output QX1
See relay output QX1
See relay output QX1
See relay output QX1
See relay output QX1
See relay output QX1
See relay output QX1
See sensor input BX2
See sensor input BX2
See sensor input BX2
See sensor input BX2
See sensor input BX2
See sensor input BX2
See function input H1
NO
NC
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor

0,6V
0
9,6V
30
Table1
NO
15
20
162
120
Room
thermostat
CH1
NO

None

None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
NO
0V
0

6051
6052
6054

2
2
2

Voltage value 2 H2 module 1


Funct value 2 H2 module 1
Function input H2 module 2

6055

Contact type H2 module 2

6057
6058
6059
6060
6062

2
2
2
2
2

Voltage value 1 H2 module 2


Funct value 1 H2 module 2
Voltage value 2 H2 module 2
Funct value 2 H2 module 2
Function input H2 module 3

6063

Contact type H2 module 3

6065
6066
6067
6068

2
2
2
2

Voltage value 1 H2 module 3


Funct value 1 H2 module 3
Voltage value 2 H2 module 3
Funct value 2 H2 module 3

6097

Sensor type collector

6098
6100
6110

3
2
3

Readjustm collector sensor


Readjustm outside sensor
Time constant building

6120

System frost protection

6200
6205
6212
6213
6215
6217
6220
6230
6231

2
3
2
2
2
2
3
2
2

Save sensors
Reset to default parameters
Check no. heat source 1
Check no. heat source 2
Check no. storage tank
Check no. heating circuits
Software version
Info 1 OEM
Info 2 OEM

Parameter

Level

Parameter for characteristic definition of sensor


Parameter for characteristic definition of sensor
See function input H1
NO
NC
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
See function input H1
NO
NC
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
Parameter for characteristic definition of sensor
Solar collector sensor type:
1 NTC
2 PT1000
Correction of readed collector sensor value
Correction of readed outside sensor value
Time thermic constant building
Plant frost protection (only with outside sensor):
On
Off
Stored of sensor used in plant
Not used
Manufactoring information
Manufactoring information
Manufactoring information
Manufactoring information
Manufactoring information
Manufactoring information
Manufactoring information

LPB SYSTEM

6600
6601

3
3

Device address
Segment address

6604

Bus power supply function

6605

Bus power supply state

6610

Display system messages

6612

Alarm delay

6620

Action changeover functions

Choice of cascade device address from 1 to 16 (1 = master)


Choice of cascade segment from 0 to 14
Bus power supply type:
Off
Timed
Bus power supply state:
On
Off
Visualization of system messages:
Yes
No
Alarm time delay
Action function changeover:
System
Segment

0V
0
None
NO
0V
0
0V
0
None
NO
0V
0
0V
0
PT1000
0C
0C
15h
Off
No
No

Table1

Default
1
0
Timed

No
--System

6621

Summer changeover

6623

Optg mode changeover

6624

Manual source lock

6625

Hot water assignment

6630

Cascade master

6631

Ext source with eco mode

6632

Note OT limit ext source

6640

Clock mode

6650

Outside temp source

Parameter

Level

6704

Display SW diagnostic code

6705
6706
6710
6740
6741
6742
6743
6745
6800
6805
6806
6810 - 6996

1
1
2
3
3
3
3
3
2
2
2
2

SW diagnostic code
Burn ctrl phase lockout pos
Reset alarm relay
Flow temp 1 alarm
Flow temp 2 alarm
Flow temp 3 alarm
Boiler temp alarm
Hot water charging alarm
History 1
SW diagnostic code 1
Burner control phase 1
History from 2 to 20

Parameter

Level

7040

Summer changeover:
Locally
Centrally
Option mode changeover:
Locally
Centrally
Lock mode:
Locally
Segment
DHW assignment:
DHW used the setting of boiler
Local CHs
DHW used the setting of boiler in same cascade segment
All CHs in segment
All CHs in system
DHW used the setting of boiler in cascade system
Cascade master:
Cascade master is the boiler also if address is not 1
Always
Automatically
Cascade master is the boiler with address 1
In ECO mode, external heat sources on the LPB are operated as follows:
Off
On hot water
On
External heat sources can be locked or released according to their own parameters, based on the outside temperature:
Yes
No
Clock mode:
Autonomously
Every boiler has own time program
Slave without remote setting
Slave boilers not use the master time program
Slave with remote setting
Slave boilers use the master time program
Master
The master time program is used
Boiler address where is connected outside sensor:
- - . - - no outside sensor connected
The first 2 numbers are hte segment number, the second part is the boiler number

FAULT
Visualization of diagnostic code:
0 No
1 Yes
Diagnostic code currently pending
Lockout phase indicating where the fault occured
Reset of alarm relay
value displayed
value displayed
value displayed
value displayed
value displayed
Last fault occured
Diagnostic code of last fault occured
Lockout phase indicating where the last fault occured
Previous fault history

SERVICE/SPECIAL OPERATION
Burner hours interval

Burner hours before boiler maintenance

Locally
Centrally
Segment
All CHs in
system
Automatically

Off

No

Autonomously

Default
Yes

No
-----------

Default
---

7041
7042
7043
7044
7045
7051

3
3
3
3
2
3

Burn hrs since maintenance


Burner start interval
Burn starts since maint
Maintenance interval
Time since maintenance
Message ionization current

7130

Chimney sweep function

7131

Burner output

7140

Manual control

7143

Controller stop function

7145

Controller stop setpoint

7146

Deaeration function

7147

Type of venting

7170
7231
7232
7233

2
2
2
2

Telephone customer service


Refilll time current week
Refill time to date
Number of refills to date

7244

Press superv water refill

7250
7251

3
3

PStick storage pos


Parameter

7252

PStick command

7253

PStick progress

7254

Parameter

Burner hours reset after boiler maintenance


Burner ignition number before boiler maintenance
Burner ignition number reset after boiler maintenance
Operation boiler time before boiler maintenance
Operation boiler time reset after boiler maintenance
Ionization current value
Chimney swwp function:
On
Off
Burner output power during chimney sweep function:
Partial load
Full load
Max heating load
Manual control function:
On
Off
Controller stop function:
On
Off
Power setpoint during controller stop function
Deaeration function:
On
Off
Deaeration function mode:
None
Heating circuit continuous
Heating circuit cycled
Hot water continuous
Hot water cycled

0h
--O
--0Month
No
Off
Max heating
load
Off
Off
100%
Off

None

0
value displayed
value displayed
value displayed
Used sensor for water pressure supervision for refill function:
None
With input H1
With input H2 module 1
With input H2 module 2
With input H2 module 3
With input H3
Selection of the dataset number to write/read
Description of dataset selected
Actions with Pstick:
No operation
Reading from stick
Writing on stick
The progress made appears as a percentage which, when stick operation is active (reading or writing) shows the
percentage already completed.
Status of Pstick:
No stick
No operation
Writing on stick

None

Reading from stick


EMC test active
Writing error
Reading error
Incompatible data set
Wrong stick type
Stick format error
Check data set
Data set disabled
Reading disabled

Parameter

Level

INPUT/OUTPUT TEST

7700

Relay test

7730
7750
7760
7820
7821
7822
7830
7831
7832
7833
7834
7835
7840
7841
7845
7846
7848
7849
7851
7852
7862
7860
7865

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Outside temp B9
Hot waterr temp B3
Boiler temp B2
Sensor temp BX1
Sensor temp BX2
Sensor temp BX3
Sensor temp BX21 module 1
Sensor temp BX22 module 1
Sensor temp BX21 module 2
Sensor temp BX22 module 2
Sensor temp BX21 module 3
Sensor temp BX22 module 3
Voltage signal H1
Contact state H1
Voltage signal H2
Contact state H2
Voltage signal H2 module 2
Contact state H2 module 2
Voltage signal H2 module 3
Contact state H2 module 3
Frequency H4
Contact state H4
Contact state H5

Operatin relays test:


No test
Everything off
Relay output QX1
Relay output QX2
Relay output QX3
Relay output QX4
Relay output QX21 module 1
Relay output QX21 module 2
Relay output QX21 module 3
Relay output QX22 module 1
Relay output QX22 module 2
Relay output QX22 module 3
Relay output QX23 module 1
Relay output QX23 module 2
Relay output QX23 module 3
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed

Default

No test

7950
7951
7952

Parameter
8000
8001
8002
8003
8005
8007
8008
8009
8010
8011
8023

Parameter
8100
8101
8102
8103
8104
8105
8106
8107
8108
8109
8110
8111
8112
8113
8114
8115
8116
8117
8118
8119
8120
8121
8122
8123
8124
8125
8126
8127
8128
8129
8130

3
3
3

Input EX21 module 1


Input EX21 module 2
Input EX21 module 3

value displayed
value displayed
value displayed

Level
2
2
2
2
2
2
2
2
2
2
2

Default

DIAGNOSTIC CASCADE

Default

State central heating CH1


State central heating CH2
State central heating CH3
State hot water
State boiler
State solar
State solid fuel boiler
State burner
State buffer
State swimming pool
State SithermPro

Level
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

STATE

Priority/state source 1
Priority/state source 2
Priority/state source 3
Priority/state source 4
Priority/state source 5
Priority/state source 6
Priority/state source 7
Priority/state source 8
Priority/state source 9
Priority/state source 10
Priority/state source 11
Priority/state source 12
Priority/state source 13
Priority/state source 14
Priority/state source 15
Priority/state source 16

value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed
state displayed
value displayed

8131
8138
8139
8140
8141
8150

Parameter
8304
8308
8310
8311
8312
8313
8314
8315
8316
8318
8321
8323
8324
8325
8326
8327
8329
8330
8331
8338
8339
8390
8499
8501
8502
8510
8511
8512
8513
8513
8514
8515
8519
8520
8527
8530
8531
8532
8560
8570

Parameter

3
3
3
3
3
3

Cascade flow temp


Cascade flow temp setp
Cascade return temp
Cascade return temp setp
Source seq ch'over current

state displayed
value displayed
value displayed
value displayed
value displayed
value displayed

Level
3
3
2
2
3
3
2
2
2
3
2
2
3
3
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
1
1
3
3

Level

Boiler pump Q1
Boiler pump speed
Boiler temperature
Boiler setpoint
Boiler switching point
Parameter
Boiler return temp
Boiler return temp setpoint
Flue gas temp
Flue gas temp max
Primary exchanger temp
Fan speed
Set point fan
Current fan control
Burner modulation
Water pressure
Ionization current
Hours run 1st stage
Start counter 1st stage
Hours run heating mode
Hours run HW
Current phase number
Collector pump 1
Solar ctrl elem buffer
Solar ctrl elem swi pool
Collector temp 1
Collector temp 1 max
Collector temp 1 min
dt collector 1/exchanger 1
dt collector 1/HW
dt collector 1/buffer
dt collector 1/swimming pool
Solar flow temp
Solar return temp
Total Solar Gain
Hours run solar
Hours run collect overtemp
Hours run collector pump
Solid fuel boiler temp
Hours run solid fuel boiler

DIAGNOSTICS HEAT GENERATION

Default

DIAGNOSTICS CONSUMERS

Default

value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value reset
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value reset
value reset
value reset
value reset
value displayed
value displayed
value displayed
value displayed
value displayed
value reset
value reset
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value reset
value reset
value reset
value reset
value displayed
value reset

8700
8701
8702
8703
8704
8730
8731
8732
8740
8741
8743
8744
8749
8760
8761
8762
8770
8771
8773
8774
8779
8790
8791
8792
8800
8801
8804
8803
8809
8820
8830
8831
8832
8835
8836
8852
8853
8860
8875
8885
8895
8900
8901
8930
8931
8950
8951
8952
8962

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Outside temp
Outside temp min.
Outside temp max.
Outside temp attenuated
Outside temp composite
Central heating pump 1
Heat circ mix valve 1 open
Heat circ mix valve 1 close
Room temp 1
Room setpoint 1
Flow temp 1
Flow temp setpoint 1
Room thermostat 1
Central heating pump 2
Heat circ mix valve 2 open
Heat circ mix valve 2 close
Room temp 2
Room setpoint 2
Flow temp 2
Flow temp setpoint 2
Room thermostat 2
Central heating pump 3
Heat circ mix valve 3 open
Heat circ mix valve 3 close
Room temp 3
Room setpoint 3
Flow temp 3
Flow temp setpoint 3
Room thermostat 3
Hot water pump
Hot water temp 1
Hot water temp setpoint
Hot water temp 2
Hot water circulation temp
HW charging temp
Instant HW heater temp
Instant HW heater setpoint
Hot water flow
Flow temp setp VK1
Flow temp setp VK2
Flow temp setp VK3
Swimming pool temp
Swimming pool setpoint
Primary controller temp
Primary controller setpoint
Common flow temp
Common flow temp setpoint
Common return temp
Common output setpoint

value displayed
value reset
value reset
value reset
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed

8980
8981
8982
8983
9005
9006
9009
9031
9032
9033
9050
9051
9052
9053
9054
9055
9056
9057
9058

Parameter

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Buffer temp 1
Buffer setpoint
Buffer temp 2
Buffer temp 3
Water pressure H1
Water pressure H2
Water pressure H3
Relay output QX1
Relay output QX2
Relay output QX3
Relay output QX21 module 1
Relay output QX22 module 1
Relay output QX23 module 1
Relay output QX21 module 2
Relay output QX22 module 2
Relay output QX23 module 2
Relay output QX21 module 3
Relay output QX22 module 3
Relay output QX23 module 3

Level

value displayed
value reset
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed
value displayed

BURNER CONTROL

9500
9504
9512
9524
9529
9540

3
3
2
2
2
3

Prepurge time
Required speed prepurging
Required speed ignition
Required speed LF
Required speed HF
Postpurge time

9650

Chimney drying

9651
9652

3
3

Req speed chimney drying


Duration chimney drying

Fan running time of prepurge


Prepurging fan speed
Ignition fan speed
Minimum power fan speed
Maximum power fan speed
Fan running time of postpurge
Mode:
Off
Temporarily
Permanently
Fan speed during the function
Operation time of function

Default
1s
Table1
Table1
Table1
Table1
5s
Off
500rpm
10min

TABLE1

NUVOLA
24
Time hot
water

NUVOLA
33
Time hot
water

20

10

10

28

32

20

5750

6000

6100

Yes

Yes

Yes

45

45

45

45

45

45

25

25

-------

-------

60

1.12

1.18

1.24

1.28

1.32

24

28

33

40

MAX 24

MAX 28

MAX 33

MAX 40

2.24 HTE

2.33 HTE

1620

Time hot
water

Time hot
water

Time hot
water

Time hot
water

Time hot
water

24h/day

24h/day

24h/day

24h/day

24h/day

24h/day

24h/day

24h/day

2237

10

10

10

10

10

20

20

20

20

20

20

20

24h/day

24h/day

20

20

2330

12

18

24

28

32

20

24

28

32

20

24

2331

28

20

28

2441

4600

6400

6600

6000

6900

5600

5750

6000

6100

5600

5600

6000

5600

6000

2675

No

No

No

No

No

Yes

Yes

Yes

Yes

2681

45

45

45

45

Yes

No

No

Yes

Yes

45

45

2682

90

90

90

90

90

45

45

45

45

45

45

90

90

45

45

5020

25

25

25

25

25

25

25

5470

25

25

25

25

60

5476

-------

-------

-------

-------

-------

-------

-------

60

60

60

60

-------

-------

-------

-------

5490

On

On

On

On

On

On

On

On

On

Off

Off

Off

Off

On

On

On

On

5730

Hot water
sensor B3

Hot water
sensor B3

Hot water
sensor B3

Hot water
sensor B3

Hot water
sensor B3

HW outlet
sensor
B38

HW outlet
sensor
B38

HW outlet
sensor
B38

HW outlet
sensor
B38

HW outlet
sensor
B38

HW outlet
sensor
B38

HW outlet
sensor
B38

HW outlet
sensor
B38

Hot water
sensor B3

Hot water
sensor B3

HW outlet
sensor
B38

HW outlet
sensor
B38

5734

Central
heating

Central
heating

Central
heating

Central
heating

Central
heating

Hot water

Hot water

Hot water

Hot water

Hot water

Hot water

Hot water

Hot water

Central
heating

Central
heating

Hot water

Hot water

5892

DHW ctrl
elem Q3

DHW ctrl
elem Q3

DHW ctrl
elem Q3

DHW ctrl
elem Q3

DHW ctrl
elem Q3

None

None

None

None

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

DHW ctrl
elem Q3

None

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

DHW ctrl
elem Q3

5970

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

None

None

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

Instant
heater ctrl
elem Q34
Flow
measure
ment Hz

9504

3500

3500

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

9512

3500

3500

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

9524

1100

1100

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

9529

4600

6400

6600

6000

6900

6600

6550

7000

7000

6600

6550

7000

7000

6600

7000

6600

7000

ERROR LIST

Error
10

Outside sensor

20

Boiler sensor 1

25
26

Boiler sensor solid fuel


Common flow sensor

28

Flue gas temp sensor

30
31
32
38

Flow sensor 1
Flow sensor cooling 1
Flow sensor 2
Flow sensor prim contr

40

Return sensor 1

46
47

Return sensor cascade


Common return sensor
HW sensor 1 (boiler with
tank)
HW sensor 2
HW flow sensor
HW circulation sensor
Room sensor 1
Room sensor 2
Room sensor 3
Storage tank sensor 1
Storage tank sensor 2
Storage tank sensor 3
Collector sensor 1
Collector sensor 2

50
52
54
57
60
65
68
70
71
72
73
74
78

Water pressure sensor

81
82
83
84
85
91
98
99

LPB short-circuit/comm
LPB address collision
BSB short-circuit
BSB address collision
BSB Radio communication
Data loss in EEPROM
Extension module 1
Extension module 2

100

2 clock time masters

105

Maintenance message

109

Boiler temp supervision

Internal
Code

1
2

539
540
543
544

1
2

1
2

506
560
793
797

499

Description
Central heating enabled without any control (room
thermostat, room unit o outside sensor) or outside sensor
fault
Short circuit
Open circuit
Solid fuel boiler sensor not found or in short circuit
Common flow sensor not found or in short circuit
Short circuit (lockout)
Open circuit (lockout)
Short circuit (temporary error)
Open circuit (temporary error)
Flow sensor mixing zone 1 not found or in short circuit
Flow sensor cooling circuit not found or in short circuit
Flow sensor mixing zone 2 not found or in short circuit
Flow sensor primary controller not found or in short circuit
Short circuit
Open circuit
Return sensor cascade not found or in short circuit
Common return sensor not found or in short circuit
Short circuit
Open circuit
Solar DHW sensor not found or in short circuit
DHW flow sensor not found or in short circuit
DHW circulation sensor not found or in short circuit
Room sensor circuit 1 not found or in short circuit
Room sensor circuit 2 not found or in short circuit
Room sensor circuit 3 not found or in short circuit
Storage tank sensor 1 not found or in short circuit
Storage tank sensor 2 not found or in short circuit
Storage tank sensor 3 not found or in short circuit
Solar collector sensor 1 not found or in short circuit
Solar collector sensor 2 not found or in short circuit
Short circuit (lockout)
Short circuit (temporary error)
Automatic filling loop error (lockout)
Automatic filling loop error (temporary error)
LPB bus error
More than 1 boiler using in the same address
No comunication / comunication error
More than 1 room unit using in the same Central heating
No radio comunication
Internal counter out of range
External modul 1 not found
External modul 2 not found
Not correct configuration of clock time

503
504

Flatness 2 test on flow sensor


Flatness 2 test on return sensor

419
420
421

110

Lockout SLT

426
427
428
429
431
436
437
438

111

Shutdown limit thermost

117

Water pressure too high

118

Water pressure too low

119

Shutd water press swi

121
122

Flow temp CH1


Flow temp CH2

Maximum temperature of Electronic Safe Limit temperature


Return temperature higher than flow temperature more than
10K (temporary error)
Return temperature egual or higher than flow temperature
more than 10K-2
Temperature slope
Unlock limit of temperature slope not reached
Flow return temperature higher than 56K (temporary error)
Unlock limit of Flow return temperature higher than 56K
Accepted times return temperature higher than flow
temperature more than 10K reached (lockout error)
Electronic Safe Limit temperature on return temperature
Accepted times Temperature slope reached
Accepted times Flow return temperature higher than 56K
reached (lockout error)
Maximum limit of flow temperature

565

Static water pressure limit (lockout error) > 2.8 bar

566

Static water pressure limit (temporary error) > 2.8 bar

125

Boiler temp too high

126

HW charg temp

Static pressure limit (lockout error) < 0.5 bar


Water pressure limit (lockout error)
Water pressure limit (temporary error)
Flow temperature Central heating 1 not reached
Flow temperature Central heating 2 not reached
Reached limit of flow temperature of flow setpoint plus 30K
for 2 times in 10 minutes
No flow temperature variation for 20 seconds
No return temperature variation for 20 seconds
Maximum temperature of DHW charging not reached

127

Legionella temp

Legionella limit temperature not reached

128

Loss of flame in op

Loss of flame during operation

130

Flue gas temp too high

Flue temperature limit reached

132

Safety shutdown

Lock on GP contact

133

Safety time exceeded

Loss of flame during ignition phase

563
564

500

151

BMU internal

152

Parameterization

501
502

325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
345
346

Software error
Software error
Software error
Software error
Software error
Ingniter relay closing error
Ingniter relay opening error
Gas valve relay closing error
Gas valve relay opening error
Ingnition error of canal 2
Swithing off error of canal 2
Safety relay closing error
Safety relay opening error
Ingnition error of canal 1
Swithing off error of canal 1
Software error on micro 1
Gas type change error

347
348
349
350
572
573
574
575
576
577
578
579
580
581

Max fan speed <= Max fan speed accepted


Prepurge fan speed <= Prepurge fan speed accepted
Minimum fan speed >= Minimum fan speed accepted
Postpurge fan speed >= Postpurge fan speed accepted
Input HX parameterization: limit thermostat
Input HX parameterization
Input HX parameterization: air presure switch
10V signal input parameterization
Input H6 with 2 different funtions associated
Input H7 with 2 different funtions associated
Input B4 with 2 different funtions associated
Bypass pump Q12 parameterization
Cooling request K28 parameterization
Water filling K34 parameterization
Hardware reset button pressed more than 10 seconds
Fan speed threshold not reached
Flow pressure switch Central heating (lockout error)
Flow pressure switch Central heating (temporary error)
Alarm contact input H1
Alarm contact input H4
Alarm contact input H2 of extension module 1
Alarm contact input H2 of extension module 2
Alarm contact input H2 of extension module 3
Alarm contact input H5
Alarm contact input H6
Alarm contact input H3
Alarm contact input H7
Static water pressure limit (lockout error)
Static water pressure limit (lockout error)

153
160

Unit locked
Fan speed threshold

164

Flow press switch CH

171

Alarm contact 1 active

172

Alarm contact 2 active

173

Alarm contact 3 active

174

Alarm contact 4 active

176
177

Water press 2 too high


Water press 2 too low

178

Limit thermostat CH1

Limit thermostat Central heating 1 (mix zone)

179

Limit thermostat CH2

Limit thermostat Central heating 2 (mix zone)

195

Water refill time

196

Water refill time/week

241
242
243
260

Flow sensor yield


Return sensor yield
Swimming pool sensor
Flow sensor 3

270

Exc temp diff h' exch

320

HW charging sensor

321

HW outlet sensor

322
323

Water press 3 too high


Water press 3 too low

324

BX same sensors

325

BX/e'module same sens

326

BX/m'grp same sens

327

E'module same funct

561
562
800
805
801
802
803
806
807
804
808
565
565

791
795
792
796

507
1
2
565
565

Water refill time for sigle refilling elapsed (lockout error)


Water refill time elapsed (temporary error)
Water refill time weekly elapsed (lockout error)
Water refill time weekly elapsed (temporary error)
Flow sensor yield not found or in short circuit
Return sensor yield not found or in short circuit
Swimming sensor not found or in short circuit
Flow sensor mixing zone 1 not found or in short circuit
Temperature differential between flow temperature and
exchanger temperature - Dry fire (lockout error)
Charging DHW sensor not found or in short circuit
Short circuit
Open circuit
Static water pressure limit (lockout error)
Static water pressure limit (lockout error)
More than one sensor with the same function associated
More than one sensor (also on external module) with the
same function associated
More than one sensor (also on mixing zone) with the same
function associated
More than one sensor on external module with the same

328

Mix group same funct

329

E'mod/m'grp same funct

330
331
332
333
334
335
336
337

BX1 no function
BX2 no function
BX3 no function
BX4 no function
BX5 no function
BX21 no function
BX22 no function
B1 no function

function associated
More than one sensor on mixing zone with the same
function associated
More than one sensor (external module and mixing zone)
with the same function associated
No function associated to input BX1
No function associated to input BX2
No function associated to input BX3
No function associated to input BX4
No function associated to input BX5
No function associated to input BX21
No function associated to input BX22
No function associated to input B1

338

B12 no function

No function associated to input B12

339
340
343

Coll pump Q5 missing


Coll pump Q16 missing
Solar integration missing

Collector pump Q5 not found or not configurated


Collector pump Q16 not found or not configurated
Solar integrated not found or not configurated

344

Solar buffer K8 missing

Solar buffer not found or not configurated

345
346

Sol swi pool K18 missing


Boiler pump Q10 missing

347

Solid fuel boil comp sens

348
349
350
351
353
371
372
373

Solid fuel boil addr err


Buff valve Y15 missing
Buffer address error
Prim/sys pump addr err
Casc sens B10 missing
Flow temp CH3
Limit thermostat CH3
Extension module 3
359

Swimming pool from solar not found or not configurated


Collector pump Q16 not found or not configurated
Solid fuel boiler comparative sensor not found or not
configurated
Solid fuel boiler address error
Buffer valve not found or not configurated
Buffer address error
System pump address error
Cascade sensor not found or not configurated
Flow temperature Central heating 3 not reached
Limit thermostat Central heating 3 (mix zone)
External modul 3 not found
Control value out of range

360

Calculated value over the threshold

361

Calculated value under the threshold

362

Gas valve stepper position over the threshold

363
364

Gas valve stepper position under the threshold


Ionization current out of range

365

R value out of range

366
367
368
369
370
221
357

Open contact on stepper motor


Short circuit on stepper motor
Low supply voltage on stepper motor
High supply voltage on stepper motor
Prevention of startup for a stepper motor is interrupted
Fan speed out of range
Fan speed out of range
Ionization or fan speed with electrode drift test not in the
defined area. Problem: Power supply, blower-PWM setting
Too much corrrection of drift test
Too much corrrection of drift test
Drift test performed 4 times consecutive (temporary error)
Control value limit reached during the test drift
Ionization drift crash during testing

374

Sitherm Pro calculation

375

BV stepper motor

376

Drift test limit value

358
371
372
373
768
769

377
384
385
386

Drift test prevented


Extraneous ligth
Mains undervoltage
Fan speed tolerance

418

429

Dyn water pres too high

430

Dyn water pres too low

431

Primary exch sensor


(aluminium exchanger)

432

Function ground missing

433

Heat exch temp

558
559
557
1
2
547
548
746
747
508
509

Drift test counter monitor has excedded


Flame present with gas valve closed
Low supply voltage
Fan speed out of range
Dynamic water pressure too high (lockout error)
Dynamic test times excedded (lockout error)
Dynamic pressure test failed (lockout error)
Short circuit (temporary error)
Open circuit (temporary error)
Short circuit (lockout error)
Open circuit (lockout error)
Feedback error from PCB (SR)
Feedback erro from gas valve realy (BV1)
Exchanger temperature > 95C (lockout error)
Exchanger temperature > 95C (temporary error)

GAS ADAPTIVE SYSTEM

LUNA4 is provided with a brand new system GAC (Gas Adaptive Control): the electronic
control together with the gas valve grant an automatic control of the combustion and ensure
the following advantages during the installation as well as for the end user:
Reduction of the time for the installation, as any manual intervention has been deleted
(adjustment or nozzles change);
The boiler is able to adapt to the quality of the gas and to the length of the flue tubes
maintaining a constant efficiency helping a reduction of the gas consumption and generating
less pollution.
The Gas Adaptive System maintains correct combustion by comparing the measured Flame
Signal and the Reference Flame Signal. The Reference Signal follows a set curve depending
on fan speed and it is part of the software.
The system measures constantly the signal during the operation of the boiler and adjusts the
gas flow rate in order to maintain the correct signal and the correct CO level. In this way is
also considered the oxidation of the component (flame electrode and burner).
The electronic gas valve has a modulator used to set the properly flame signal and so the
correct air / gas ratio (LAMBDA).
If the system is not able to assure the correct flame signal the boiler goes in lockout.
The flame signal detected by the burner control is independent from:
- value and type of supply voltage;
- quality of the ground in the installation.

FAULT FINDING
1 Initial Fault Finding Checks
1. Check that gas, water and electrical supplies are available
at the boiler.
NOTE: When instructed press and hold
the Reset for between 1-3 seconds to
reset the boiler.

2. Electrical supply = 230V ~ 50 Hz.


4. The preferred minimum gas pressure is 10 mbar.
5. Carry out electrical system checks, i.e. Earth Continuity,
Resistance to Earth, Short Circuit and Polarity with a suitable
meter.
NOTE: These checks must be repeated after any
servicing or fault finding.
6. Ensure all external controls are calling for heat and check
all external and internal fuses. Before any servicing or
replacement of parts, ensure the gas and electrical supplies
are isolated.

18.2 Error Codes


Table Of Error Codes

1. If a fault occurs on the boiler an error code may be shown


by the facia display.

E20

Central Heating Flow NTC Fault

2. The codes are either a flashing two or three digit, number


preceded by the symbol 'E '.

E28

Flue NTC Fault

E40

Central Heating Return NTC Fault

E50

Hot Water NTC Fault

E83

Communications error

E109

Pre-Circulation Fault

E110

Safety Thermostat Operated

E111

Maximum flow temperature exceeded

E117

System Water Pressure Too High

E118

System Water Pressure Too Low

E125

Circulation Fault (Primary Circuit)

E128

Flame Failure

E130

Flue NTC Operated

E133

Interruption Of Gas Supply or Flame Failure

E151

PCB Fault

E160

Fan or Fan Wiring Fault

E384

False flame

E20, E28, E40, E50, E83, E151, E160

and E384 indicate possible

faulty components.
E110

and E111 shows overheat of the primary.

E117 is displayed when the primary water pressure is more


than 2.7 bar.
E118 is displayed when the primary water pressure is less
than 0.5 bar.
E133

indicates that the gas supply has been interrupted,


ignition has failed or the flame has not been detected.
E125 is displayed in either of two situations:i) If within 15 seconds of the burner lighting the boiler
temperature has not changed by 1.
ii) If within 10 minutes of the burner lighting the boiler
temperature twice exceeds the selected temperature by 30.
In these instances poor primary circulation is indicated.
E128 is displayed if there has been a flame failure during normal
burner operation.

3. By pressing the 'Reset' button for between 1-3 seconds when


E 110, E125 & E133 are displayed it is possible to relight the
boiler.
4. If this does not have any effect, or error codes are displayed
regularly further investigation is required.
.

Refer to Annex 1 Illustrated Wiring Diagram for position of terminals and components
Central Heating - Follow operational sequence
NO
*
Turn on mains power.
Go to section A
If Error 83, 151 or 384 is flashing or re-occurs regularly
The display illuminates
check all PCB and communication connections, if this has
no effect change PCB.
YES
*
Error 110 flashing
Error 111 flashing
Error 133 flashing
Error 125 flashing

YES

NO

Press the Reset button for


between 1-3 seconds

NO

If the E110 or E111 is still


flashing. Go to section H

YES

Error 20, 28, 40 or 50 flashing

Go to section D

NO
YES

Go to section I

Error 117 or 118 flashing


NO

Ensure controls are set to


demand and verify the
contacts are closed

CH Rad. Symbol flashes


NO
NO

Set the Central Heating


temperature to
Maximum. Pump runs.

YES

Ensure all controls and


Programmers are calling
for heat

Go to section B

YES

Fan runs after up to 3 minutes

NO

Error 160 flashing


Go to section C

NO

Error 160 flashing


Go to section C

YES

Fan runs at correct speed


YES

Spark at ignition electrodes for


up to 5 seconds and for 4
attempts.
YES

NO

YES

Error 133 flashing

Go to section F
Press the Reset button for
between 1-3 seconds

Go to section E

NO

YES

YES

Burner does not stay alight


after 5 seconds

Burner lights
YES
YES

Error 128 or Error 374 flashing. Go to section N


YES

Error E125 flashing


after 1 minute

Error E109 flashing

Error 133 flashing. Go to section G

NO

Go to section J

NO
YES

Error E110 or E111


flashing

Go to section H

NO
NO

3 way valve open to central


heating circuit

Go to section K

YES

Burner output modulates to


maintain the temperature set
YES

Error E130 flashing


NO

Burner goes out

YES

NO

Check the Central Heating


NTC sensor
Go to section D

Go to section M

YES

YES

Fan stops after 10 seconds

Operation sequence
successful

Domestic hot water - Follow operational Sequence


NO

Turn on mains power.


The display illuminates

Go to section A
*
If Error 83, 151 or 384 is flashing or re-occurs regularly
check all PCB and communication connections, if this has
no effect change PCB.

YES

*
Error 110 flashing
Error 111 flashing
Error 133 flashing
Error 125 flashing

YES

NO

NO

Press the Reset button for


between 1-3 seconds

If the E110 or E111 is still


flashing. Go to section H

YES

Error 20, 28, 40 or 50 flashing

Go to section D

NO
YES

Go to section I

Error 117 or 118 flashing


NO

YES

DHW Tap. Symbol flashes

Set Domestic Hot Water


temperature to Maximum.
Open DHW tap fully.
Pump runs.

NO

DHW flow rate more


than 2 l/min

YES

Go to section B

Burner lights
NO

NO

Go to section L

Go to section L

YES

NO

Fan runs at correct speed

Error 160 flashing


Go to section C

YES

Spark at ignition electrodes for


up to 5 seconds and for 4
attempts.
YES

YES

NO

Error 133 flashing

Go to section F
Turn the selector switch to
reset

Go to section E

NO

YES
YES

Burner does not stay alight


after 5 seconds

Burner lights
YES
YES

Error E125 flashing


after 1 minute

Error E109 flashing

Error 133 flashing. Go to section G

NO

Error 128 or Error 374 flashing. Go to section N


YES

Go to section J

NO
YES

Error E110 flashing or


Error E111 flashing

Go to section H

NO
NO

3 way valve open to domestic


hot water circuit

Go to section K

NO
NO

Burner output modulates to


maintain the temperature set

Check the Central Heating


NTC sensor
Go to section D

YES

Error E130 flashing

YES

Go to section M

NO
YES

Burner goes out

YES

Fan stops after 10 seconds

Operation sequence
successful

Fault Finding Solutions Sections

Is there 230V at:


NO

1.

Main terminals L and N

Check electrical supply

YES

NO

2.

Main terminal fuse

Replace fuse

YES

Display
illuminated

NO

3.

PCB X10 connector


Mains terminals L & N

Connection OK at
connector x40

Check wiring

Main or Display
PCB fault

NO

Switch to DHW mode maximum flow rate and press


reset. During the next three minutes is there:-

230V at PCB connector x13 pump terminals


Blue to Brown (See Wiring Diagram)

YES

230V between PCB connector x13 pump


terminal Blue and PCB connector x11 pump
terminal Black.
(See Wiring Diagram)

NO

Replace PCB

YES

230V at
Pump

YES

NO
NO

Replace PCB

Replace
Pump

Check wiring

NO

1.

Fan connections correct at fan and PCB


Connectors X11 & X23 See Wiring Diagram

Make connections

YES

YES

Is there 230V AC at fan terminals connector


X11 blue to brown. See Wiring Diagram
NO

Replace PCB

YES

Fan jammed of faulty winding

Replace fan

Temperature sensor faulty.


Check correct location and wiring

YES

Cold resistance approximately


10k @ 25 C (DHW and CH sensors)
(resistance reduces with increase in temp.)

Gas at burner

NO

NO

Replace sensor

Ensure gas is on and purged

Check wiring & PCB X15 connector, is there 24 V


DC across Gas valve terminals black to green.
See Wiring Diagram.

YES

Replace gas valve

NO

Replace PCB

Check and correct if necessary


1. Ignition electrode and lead
2. Electrode connection
3. Spark gap and position

YES

Check wiring.
Voltage at PCB X15 connector is
24V DC across the igniter unit
terminals Blue to Brown for 5
seconds during ignition phase . See
Wiring Diagram

1.

Check the gas supply pressure:


For Natural Gas greater than
10 - 11 mbar

2.

Check and correct if necessary


1.CO2 values - see instruction
2. Flame sensing electrode and lead connections
3. Flame sensing electrode position

Flame current should be more than 1,7 A

YES

NO

NO

YES

Replace PCB

Replace flame sensing electrode

Replace PCB

Replace igniter unit

Overheat thermostat operated or


faulty.

NO

Check for and correct any


system faults.
NO

Allow to cool. Continuity


across thermostat terminals
more than 1.5 ohm
NO

YES

YES

Check Flow, Return,


sensors. See section D

CH system pressure less than 0.5 bar


or more than 2.7 bar.

NO

Ensure that the system and


boiler are fully vented.

YES

Is E110 or E111 still


flashing

YES

Replace pressure sensor

NO

Replace PCB

System fault, correct.

Check flow temperature sensor connections


and position.
Cold resistance approximately.
10k @ 25 C (CH sensors)
(resistance reduces with increase in temp.)

YES

YES

Restore System Pressure

Check wiring and pcb connection at


connector x22 is there approx. 5 V
DC between the green and black
terminals

NO

Replace safety thermostat

NO

YES

Go to section B

Is there 230V at:

K
1

PCB connector x13 3 way valve terminals


Blue to Black central heating mode
Blue to Brown domestic hot water mode
See Wiring Diagram

NO

Replace PCB

YES

Check 3 way valve cable.

Motor, 3 way valve

YES

Replace motor 3 way valve

Replace sensor

Replace
PCB

Is mains water filter and


assembly clean and the rotor free
to move.

YES

PCB connector x22


Hall effect sensor terminals.
Check that the voltage is approximately
5 V DC between Red and Blue
See Wiring Diagram

YES

Replace Hall Effect Sensor

NO
NO

Clean or replace

Replace PCB

M
1.

2.

Temperature sensors faulty.


Cold resistance approximately
10k @ 25 C (CH sensor)
20k @ 25 C (Flue sensor)
(resistance reduces with increase in temp.)

NO

Replace sensor

YES

If pump is running the heat exchanger could be


obstructed

Replace heat exchanger

N
E128 flashing
E374 flashing

Check if there is
recirculation of flue gas in
the sealed chamber

YES

NO

1.

NO

2.

E376 flashing

YES

1.

Check and correct if


necessary:
1. Selection of gas type
2. Flame sensing
electrode position

Check supply pressure at


the gas valve
Check and correct if
necessary:
1. Selection of gas type
2. Flame sensing
electrode and lead
connections
3. Flame sensing
electrode position

Check wiring and PCB X25 connector (stepper


motor gas valve) and X15
(EV gas valve)

Reset Drift Test results:


-press both buttons for 6 seconds
-enter at specialist level
-go to Sitherm Pro menu
-go to parameter 2749
-select yes

YES

NO

Replace PCB
Replace flame
sensing
electrode

YES

Replace gas
valve

NO

Replace PCB

WIRING DIAGRAM

BURNER PHASE (fault history)

Phase
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Description
Permitted afterburn time
Permitted time with air pressure switch closed or fan speed
Permitted time with fan speed
Standby
Start prevention
Maximum fan ramp-up time to prepurge speed
Maximum fan ramp-up time to ignition speed
Preventilation
Maximum time to reach ignition speed after prepurging
Maximum waiting time 1
Maximum waiting time 2
Preignition time
1st safety time (gas valve open)
2nd safety time (gas valve close)
Interval (flame stabilization)
Control mode
Change to postpurging at last operating speed
Change to postpurging at prepurge speed
Postpurging at last operating speed
Temporary error
Lock-out error
Postpurging at prepurge speed
Chimney drying