Weld-on mounting

Sensor type T50

Mounting via retainer straps


Sensor type M30

Mounting accessories for levelprox sensors


Type

Description

Sensor type

LP-MS-T50-S

Mounting kit1) for welding

T50

LP-MS-T50-K

Mounting kit1) for durable adhesion

T50

LP-MS-T50-T

Mounting kit1) for temporary adhesion

T50

(for test purposes)


LP-MZ-M30-SB

The teach procedure is also


very simple. All
you have to do is to
press the teach button
once upon presenting the empty
and the filled container states.
Then simply select the sensors
operating mode and thats it.

combined welding and retainer


strap holding device

LP-MZ-M30-B250

retainer strap, total length = 250 cm,

M30

and two turnbuckles


LP-MZ-M30-B500

retainer strap, total length = 500 cm

M30

500 cm and two turnbuckles


LP-MZ-M30-B1000

retainer strap, total length = 1000 cm

M30

and two turnbuckles


1)

The mounting kit consists of the clamp adapter, the clamping seal and collar
and an additional dual compound adhesive for the adhesive mounting kit.

The advantages of
levelprox
Liquid level detection with levelprox
is hygienic and works just as well
with aggressive liquids as with
pressure tanks. You may replace or
change the sensor position at any
time without having to open the
container.
Detection of liquids through the
wall of the container or tank
Suited to a variety of container
materials such as metal or glass
Particularly hygienic due to noncontact sensing
Various mounting options:
welding, adhesive or retainer
strap mounting

M30

levelprox applications
Subsequent sensor installation
or switch-point modification
(reposition sensor using adhesive
or retainer strap mounting)
Alarm indication in the event of
errors or insufficient coupling;
the T50 version is additionally
equipped with an alarm output
Automatic teach-in of ambient
conditions
Two operating modes: reverberation and echo mode

Food industry
Hydraulics
Mechanical engineering
Pharmaceutical industry
Process industry

levelprox
NON-INVASIVE
FILLING LEVEL
CONTROL
IN METAL
CONTAINERS

Bitte senden Sie mir Unterlagen:

Please send me more information:

Sensortechnik
Induktive Sensoren
Induktive Sensoren fr
Schwenkantriebe
uprox induktive Sensoren
Kapazitive Sensoren
Magnetfeldsensoren
Opto-Sensoren
Gerte fr den Personenschutz
Ultraschall-Sensoren
levelprox-Fllstandssensoren
Strmungswchter
Druckwchter
Temperaturwchter
Identifikations-Systeme
Linearweg-Sensoren
Drehweg-Sensoren
Steckverbinder
CD-ROM Sensortechnik

Sensors
inductive sensors
inductive sensors for rotary
actuators
uprox inductive sensors
capacitive sensors
magnetic-field sensors
photoelectric sensors
machine safety equipment
ultrasonic sensors
levelprox level sensors
flow controls
pressure controls
temperature controls
identification systems
linear position sensors
rotary position sensors
connectors
CD-ROM Sensors

Interfacetechnik
Interfacetechnik im Aufbaugehuse
fr Hutschienen- (DIN 50022),
Platten- oder Bodenmontage
Interfacetechnik auf 19"-Karte
fr Baugruppentrger (DIN 41494)
Miniaturrelais, Industrierelais,
Zeitwrfel, Sockel
Zeit- und berwachungsrelais
Ex-Schutz Grundlagen fr
die Praxis (bersichtsposter)
CD-ROM Interfacetechnik

Interface technology
devices in modular housings
for top-hat rail (DIN 50022) or
panel mounting
devices on 19" card
for DIN-rail mounting (DIN 41494)
miniature relays, industrial
relays, time cubes, sockets
programmable relays and timers
explosion protection basics for
practical application (overview poster)
CD-ROM Interface technology

Feldbustechnik
busstop-Feldbuskomponenten
Bussystem sensoplex2
Bussystem sensoplex2Ex
Bussystem sensoplexMC
Bussystem AS-Interface
Bussystem DeviceNet
Ethernet Netzwerkkomponenten
BL20 I/O-Busklemmensystem
Bussystem FOUNDATION
fieldbus
Bussystem PROFIBUS-DP
Bussystem PROFIBUS-PA
Bussystem piconet
Remote I/O excom

Fieldbus technology
busstop fieldbus components
bus system sensoplex2
bus system sensoplex2Ex
bus system sensoplexMC
bus system AS-Interface
bus system DeviceNet
Ethernet network components
BL20 I/O bus terminal system
bus system FOUNDATION
fieldbus
bus system PROFIBUS-DP
bus system PROFIBUS-PA
bus system piconet
Remote I/O excom

FAX-ANTWORT/FAX REPLY
Absender/Sender:

Hans Turck GmbH & Co. KG


D-45466 Mlheim an der Ruhr
Phone
(+49) (2 08) 49 52-0
Fax
(+49) (2 08) 49 52-264
E-Mail
turckmh@mail.turck-globe.de
Internet www.turck.com

Name:
Firma/Company:
Abt./Position:
Adresse/Address:

Tel./Phone:
E-Mail:

Fax:

D101317 1003

Despite the complex operating


principle, installation and set-up of
our levelprox sensors are childs
play. TURCK offers two different
mounting kits for each of the sensor versions (welding, adhesive or
retainer strap mounting). The transducer head is spring supported to
ensure constant optimal pressure
force. The silicone gel OKS110 is
used as a coupling medium. The
ultrasound gel easily attaches to
the container wall, retains its elasticity even when exposed to high
temperatures, and is physiologically
safe.

*D1013081003*

INSTALLATION AND SET-UP

levelprox NON-INVASIVE LEVEL DETECTION IN METAL CONTAINERS

Function principle

Housing styles

levelprox sensors generate a high


frequency ultrasonic pulse which is
coupled to the container wall from
the outside using a coupling gel.
This pulse propagates within the
wall and the liquid and is reflected
by several surfaces.
The reflection characteristics
indicate whether there is liquid at
the sensor level.

The M30 version has been


designed for
all kinds of level sensing tasks in
mechanical engineering, but also
for less complex food industry
applications.
The sensor is
mounted
easily and cost effectively. The
teach procedure is initiated by a
separate teach line, which is connected to the power supply via a
PLC or our teach adapter VB2-SP1
(see drawing overleaf).

Operating modes
In the reverberation mode, the
reflections of the inner wall adjacent
to the sensor are evaluated (see
drawing). Gas bubbles or particles
in the liquid and installations such
as stirring devices hardly affect the
sensor; yet if the container is
empty, no residues should adhere
to the container wall. Should this
not be avoidable, we recommend
the echo mode (see drawing). In
this mode, the echo of the opposing inner wall is evaluated. Since
the sound has to traverse the container twice, the liquid should preferably be homogeneous and free
of contamination. Built-in fixtures
are admissible, provided they act
as a reflective surface.

Reverberation mode
The T50 sensor is particularly suited to applications in the food and
pharmaceutical industry.
The sensor is mounted
with Tri-clamp connections typically used in
these sectors. The clamp
adapter is either welded or
adhered to container wall.
The sensor is then inserted
into the adapter, sealed
with the clamping seal and
finally fixed in position with
the clamping collar. These
standard mounting accessories are available as a complete
mounting kit.

Our levelprox sensors LPRE-T50...


and LPRE-M30... may be operated
in both modes, thus ensuring optimum and reliable sensor function in
all applications.

Echo mode

Device type
LPRE-M30-AP6X2-H1141
LP-T50-UP6X3-H1151
LPRE-T50-UP6X3-H1151

Operating mode
reverb./echo
reverberation
reverb./echo

Programming
teach line
teach button/teach line
teach button/teach line